HomeMy WebLinkAboutTRUSS PAPERWORKRE: M11323 MiTek USA, Inc.
62' Grand Carlton III with porch 6904 Parke East Blvd.
Tampa, FL 33610.4115
Site Information:
Customer: WYNNNE DEVELOPEMENT CORP Project Name: M11323
Lot/Block: Model: M111323
Address: N/A
City: PORT ST LUCIE
Subdivision:
State: FL
SCANNED
BY
#, Lucie County
General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special
Loading Conditions):
Design Code: FBC2017/TPI2014 Design Program: MiTek 20/20 8.1
Wind Code: ASCE 7-10 Wind Speed: 165 mph
Roof Load: 37.0 psf Floor Load: N/A psf
This package includes 13 individual, dated Truss Design Drawings and 0 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules.
No. Seal# Truss Name Date
1
T13302390
a
2/21/18
2
T13302391
a5
2/21118
3
T13302392
a6
2/21/18
4
T13302393
a7
2/21118
5
T13302394
a8
2/21/18
6
T13302395
a9
2/21118
7
T13302396
gra
2/21/18
8
T13302397
qqrb
2/21/18
9
T13302398
12
2/21/18
10
T13302399
14
2/21118
11
T13302400
16
2/21/18
12
T13302401
8
2/21/18
13
T13302402j8.
2/21/18
The truss drawing(s) referenced above have been prepared by
MiTek USA, Inc. under my direct supervision
based on the parameters provided by Chambers Truss.
Truss Design Engineer's Name: Albani, Thomas
My license renewal date for the state of Florida is February 28, 2019.
Florida COA:6634
IMPORTANT NOTE: The seal on these truss component designs is a certification
that the engineer named is licensed in the jurisdiction(s) identified and that the
designs comply with ANSI/fPI 1. These designs are based upon parameters
shown (e.g., loads, supports, dimensions, shapes and design codes), which were
given to MiTek. Any project specific information included is for MiTek
customers file reference purpose only, and was not taken into account in the preparation of
these designs. MiTek has not independently verified the applicability of the design
parameters or the designs for any particular building. Before use, the building designer
should verify applicability of design parameters and properly incorporate these designs
into the overall building design per ANSI/TPI 1, Chapter 2.
f q(e
180
' STA E OF :��Z
O t p•p ' �_���
,•,��s`S�ONAI �C?%.
Thomas A. Albert PE No.39380
MITek USA, Inc. R. Dart 66M
6904 Parke East Blvd. Tampa R. 33610 February 21,2018
-I of 1 Albani, Thomas
Job
Truss
Truss Type
City
Ply
Canton III with porch
T13302390
M11323
A
COMMON
9
1
�62'Grarrd
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
;it
2.
4.00 12 4x5 =
27
8.130 s Sep 15 2017 MiTek Industries, Inc. Wed Feb 21 14:19:53 2018 Page 1
KnnZweXvJckSFBawFUN-iltla6GS6xdm_ITrOI?CZC_IGrGmYZaVX1111 xziuKK
Scale = 1:57.8
17- 15 -- - 14 -- 12
316 = 24 11 416 3xB = 3x8 = 46 2.3 11 3x6 =
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (Joe) Vdefl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.39
Vall LL)
0.32 14-15 >999 36D
MT20 2441190
TCDL 7.0
Lumber DOL
1.25
BC 0.58
Vert(CT)
-0.61 14-15 >670 240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.65
Horz(CT)
0.12 10 n/a Na
BCDL 10.0
Code FBC2017/rP12014
Matrix -MS
Weight: 1631b FT=O%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 3-7-12 oc puriins.
BOT CHORD 2x4 SP M 30
BOT CHORD Rigid ceiling directly applied or 4-11-7 oc bracing.
WEBS 2x4 SP No.3
-
REACTIONS. (lb/size) 2=1362/0-8-0, 10=1362/0-8-0
Max Horz 2=-179(LC 8)
Max Uplift 2=-832(LC 10), 10=-832(LG 10)
FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3419/2395, 3-5=-2771/2031, 5-6=-2770/2152, 6-7=-2770/2152, 7-9=-2771/2031,
9-10=-3419/2395
BOT CHORD 2-17=-2132(3213, 15-17=-2132/3213, 14-15=-1269/2000, 12-14= 2132/3213,
10-12=-2132/3213
WEBS 6-14=-635/983,7-14=-313/362, 9-14=-689/499, 6-15=-635/983, 5-15=-313/362,
3-15=-689/499
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14f; B=52ft; L=34ft; save=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Extedor(2) -1-0-0 to 2-4-13, Intedor(1) 2-4-13 to 13-7-3, Exterior(2) 13-7,3
to 17-0-0, Intedor(1) 204-13 to 31-7-3 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL= 10.Opsf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joints) except (tt=lb)
2=832, 10=832.
6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 50 lb down and 47 lb up at
15-0-0, and 50 Ib down and 47 lb up at 19-0-0 on top chord. The design/selection of such connection device(s) is the responsibility
of others.
7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead+ Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pli)
Vert: 1-6=-54, 6-11=54, 18-21=-20
Concentrated Loads (lb)
Vert: 26=50(F) 27=-50(F)
Thomas A Alban! PE No,39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
February 21,2018
OWARNING-Venlydeslgnpsrzmetersend READNO7ES ON MIS AND BICLUDEDMREKREFERANCEPAGEMg7473ne. 1DAa201SBEFORE USE
Design valid for use only with MRek® connectors. This design Is based only upon parameters shown, and 6 for on individual building component not
a moss system. Before use, the building designar must verity the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members any. Addltlonot temporary and permanent bracing
MiTek-
Is always requeed for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fobAcotlon, storage, delivery, stetson and bracing of musses and truss systems, seeANSU1Pi1 Du CtBerlo. DSB-89 and BCSI Building Component
Safety Nfonnatbtpvcilablo from Truss Plate Institute, 218 N. Lee Sheef, Sune 312 Alexantltla, VA 22 14.
6904 Palle East Blvd.
Tempe, FL 338ID
Joh
Truss
Truss Type
Ory
Ply
62' Grand Canton III with porch
T13302391
M11323
AS
SPECIAL
9
1
_
Job Reference (optional)
Unamp6rs I Fuss, Inc., Fort Flerce, FL 8.13U S Sep 15 2U17 MI I eK Inaustnes, Inc. Wee Yea 21 14:1 a:54 21.016
6
d
Scale=1:59.8
4eO 12 5.8 ll
6
13 12
3x12 2.00 12
5x12 = 2x3 II 3.6 =
=
LOADING (psp
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017/7PI2014
CSI.
TC 0.85
BC 0.90
WE 0.60
Matrix -MS
DEFL. in (too) Vdefl Ud
Vert(LL) 0.76 14 >539 360
Vert(CT)-1.1813-14 >344 240
Horz(CT) 0.36 10 n/a n/a
PLATES
MT20
MT18HS
Weight: 155 he
GRIP
2441190
244/190
FT=0
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 1-7-8 oc purlins.
BOT CHORb 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 3-9-12 oc bracing.
WEBS 2x4 SP No.3 *Except*
WEBS
1 Row at midpt 6-14
6-14: 2x4 SP M 30
OTHERS 2x4 SP No.3
REACTIONS. (lb/size) 2=1312/0-8-0, 10=1312/0-8-0
Max Horz 2=-179(LC 8)
Max Uplift 2=-803(LC 10). 10110)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-5529/3776, 3-5=-5164/3538, 5-6=-5209/3667, 6-7=-2424/1902, 7-9=-2462/1813,
9-10=3195/2210
BOT CHORD 2-14=-3466/5266, 13-14=-1305/2115, 12-13=-194812995, 10-12=-1948/2995
WEBS 3-14=-355/314, 5-14=-293/354, 6-14=-2175/3326, 6-13=-279/534, 7-13=-237/277,
9-13=-786/560, 9-12=0/269
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2pst BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 13-7-3, Exterior(2) 13-7-3
to 17-0-0, Interior(1) 20-64 to 31-7-3 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) All plates are MT20 plates unless otherwise indicated.
4) This truss has been designed fora 10.0 psf bottom chord live load nonconcument With any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Bearing at joint(s) 2 considers parallel to grain value using ANSVrPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001le uplift at joint(s) except at=lb)
2=803, 10=803.
Thomas A. Albani PE No.39380
MTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
February 21,2018
O WARNING- Vedrydestgn parameters and READ NOTES ON THISANO INCLUOEGM KREF£RANCEPAGEM6)473rev. 1G=0156EFOREUSE
Design valld for use only with MOe'x® connectors. This design Is based only upon parameters shown, and Is for an Individual bullding component, not
o truss system. Before use, the building designer must verity the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent bucking of lndNldual truss web and/or chord members only. Additional temporary and permanent bracing
Is always required for stabuny and to prevent collapse with possible personal Injury antl properly damage. For general guidance regarding Me
fabrlcatlon. storage, delivery, erection and bracing of losses and truss systems, seeANSVTPII Quo CMeM, DSB-09 and BCSI aWdYrp Comllon�nt
SaletY brfonnotbrpvaAable from Truss Plate Institute. 218 N. Lee Sleet. Sun. 312, Alexandre,VA 2231 A.
MiTek'
6904 Parke East Blvd.
Tampa, FL WBIO
Truss
Truss Type
Oty
Ply
62' Grand Cadton III with porch
rJob
T73302392
M11323
�A6
SPECIAL
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
6
4.00 Fl2
axle = 2.00 12
6x8 = 5x6 =
B.130 s Sep 15 2017 MiTek Industries, Inc. Wed Feb 21 14:19:55 2018
5x6 =
as II
10-6-4 150-0 0-0-08 2e5 0.0
2I10-E4 &0-1
3x6
Scale = 1:61.9
Plate Offsets (X Y)—
[2:0-1-15 Edge] [3:0-3-0 Edgel [5:0-4-0 0-23]P:0-2-7
Edge][9:0-0-6 Edge]
LOADING (pat)
SPACING- 2-0-0
CSI.
DEFL.
in (lac)
Udell
L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC
0.81
Vert(LL)
0.69 14
>590
360
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC
0.93
Vert(CT)
-0.92 14-17
>443
240
MT18HS
244/190
BCLL 0.0
Rep Stress Incr YES
WB
0.86
Horz(CT)
0.34 9
nfa
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Weight: 1571b
FT-=0%
LUMBER -
TOP CHORD
2x4 SP M 30 *Except*
3-5,6-7: 2x4 SP M 31
BOT CHORD
2x4 SP M 30
WEBS
2x4 SP No.3 *Except*
5-14: 2x4 SP M 30
OTHERS
2x4 SP No.3
REACTIONS. (lb/size) 2=1312/0-8-0, 9=1312/0-8-0
Max Horz 2=-169(LC 8)
Max Uplift 2=-803(LC 10). 9=-803(LC 10)
BRACING -
TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc puffins.
BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-5491/3336, 4-5=-5095/3071, 5-6=-2314/1551, 6-8=-2398/1533, 8-9=-3199/1981
BOT CHORD 2-14=3040/5224, 13-14=-1195/2361, 12-13=-1123/2199, 11-12=-1731/3001,
9-11=-1731/3001
WEBS 4-14=-492/513, 5-14=-1707/2959,5-13=-405/196, 6-13=-179/522, B-12=-893/660,
8-11=0/303
NOTES-
1) Unbalanced mot live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL--4.2pst BCDL=3.Opsf; h=1Art; B=52ft; L=34ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Intenor(1) 2-4-13 to 31-7-3, Extenor(2) 31-7-3
to 35-0-0 zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water pending.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 par bottom chord live load nonconcument with any other live loads.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Bearing at joint(s) 2 considers parallel to grain value using ANSVTPI 1 angle to grain formula. Building designer should verity
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100Its uplift at joint(s) except (jt=lb)
2=803, 9=803.
Thomas A. Alban! PE No.39380
MiTek USA, Inc. FL Cad 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
February 21,2018
Q WARNING -Verhydcsfgn parameters andREAD NOTES ON THISAND MCLUD£D MREKREFERANCEPAGEMIL7473 rev. faM2015BEFOREUSE
Deslgn valld for use only with MOek® connectors. This design Is based only upon parameters shown, and Is for an IndNitluol buhding component, not
��
a truss system. Before use, me building designer must verify the applicability of design parameters and property hcolporate this design Into the overoll
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only, Additional temporary and bracing
MiTek'
permanent
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regordIng the
fabrication, storage, deWery, erection and bracing of busses and truss systems, seeANSVIPII Que18v Criteria, DSB-B9 and Befit BWtlhp Component
Booty Infomrafiawwallable from Tuts Plate 218
Bard Parke East 13W.
Tampa, FL 33610
Institute. N. Lee Sheet Suite 312. Alexandria, VA 22314.
Job
Truss
Truss Type
ON
Ply
62' Grand Carlton III with porch
T13302393
M11323
A7
SPECIAL
1
1
Job Reference (optional) i
Chambers Truss, Inc., Fort Pierce, FL
5xB =
4 anFw
3x12 = 2.00 12
8.130 a Sep 152017 Mllex lndustnes,Inc. Wed Feb 21 14:19:56 2018
5x6 =
ro g
5x12 = 2x3 II
10-fi-4 14.0-0 20.4.8 25-11-15 34-0.0
10-6-4 3-s-12 fi-4-8 s-7-7 R-0-1
3x6 =
Scale = 1:60.8
Plate Offsets (X Y)--
12:0-1-15 Edge] f4:0-4-0 0-2-31 f7:0-0-2
Edael
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc)
Vdefl
Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1,25
TC 0.83
Vert(LL)
0.66 11
>616
360
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.90
Vert(CT)
-1.1010-11
>369
240
MT18HS
2441190
BCLL 0.0 '
Rep Stress [nor YES
WB 0.95
Horz(CT)
0.34 7
1
r1/a
BCDL 10.0
Code FBC2017/rP12014
Matrix -MS
Weight: 147 lb
FT=O%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
BOT CHORD 2x4 SP M 30 BOT CHORD
WEBS 2x4 SP No.3 -Except*
4-11: 2x4 SP M 30
REACTIONS. (lb/size) 2=1312/0-8-0, 7=1312/0-8-0
Max Hoa 2=-149(LC 8)
Max Uplift 2=-803(LC 10). 7=-803(LC 10)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD 2-3=-5484/3370, 3.4=5116/3126, 4-5= 2229/1544, 55=-2448/1599, 6-7— 3169/1993
BOT CHORD 2-11=-3071/5219, 10-11=-1590/2874, 9-10— 1738/2968, 7-9>7738/2968
WEBS 3-1 1=-419/443,4-1 1=-1466/2647, 4-10=-812/448, 5-10=-205/487, 6-10=-785/575,
6-9=0/272
Stmctural wood sheathing directly applied or 2-2-0 oc puriins.
Rigid ceiling directly applied or 4-0-2 cc bracing.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASIDE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 31-7-3, Extedor(2) 31-7-3
to 35-0-0 zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Bearing at joints) 2 considers parallel to grain value using ANSVTPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100111 uplift at joints) except (jt=1b)
2=803, 7=803.
Thomas A. Albans PE No.39380
MiTek USA, Inc. FL Cert 8834
6904 Parke East Blvd. Tampa FL 33610
Date:
February 21,2018
,&WARNING-Ved/ydeat9np,,--aerse-d READNOTES ON TN/SAND INCLUDED MREKREFERANCEPAGEM/N4"rl 11YD1G01SBEFORE USE.
Design valid for use only with MltekO connectors. INS design Is based any upon parameters shown, and Is for an IncMdual building component not
a truss system. Before use, the building designer must verify Me opplicobillty of all parameters and properly incorporate it design Into the overall
bulidingdeslgn. Bracing Indicated Is to prevent budding oflntliNdualfrussweband/or chord members only. Additional temporary and permanent bracing
is always required for stablllN and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, Call erection and bracing of trusses and muss systems. seeANSUIPII QuiltCdbrlo, DSS419 and SCSI Bull Component
Sabty Informa8emvollobie from Truss Rate Institute. 218 N. We Street Suite 312 Alexanddp, VA 22314.
MiTek'
6904 Pads East Blvd.
Tampa, FL M610
Job
Truss
Gty
Ply
62 Grand Carlton III with porch
T13302394
M11323
AS
�Tnuss`rype
SPECIAL
1
1
Job Reference (optional)
cnamoers i ruse, mc., non rlerce, VL
e.laUs SeD lbzuif m tex
Inc. wen reo ZT 14:1 woo Lora
Scale = 1:60.6
5x6 =
30
4.00 [2 4 21 5
2x3 II 5x11 =
6 22 7 9.3
12 11
Sx12 = 3x4 = 4x5 =
3x12 � 2.00 12
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress If or YES
Code FBC2017/TP12014
CSt.
TC 0.78
BC 0.90
WB 0.69
Matdx-MS
DEFL. in (too) Vdefl Ud
Vert(LL) 0.65 12-13 >624 360
Vert(CT) -1.0812-13 >379 240
Horz(CT) 0.33 9 n/a n/a
PLATES
MT20
MT1SHS
Weight: 164 lb
GRIP
244/190
244/190
FT=0
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
Structural wood sheathing directly applied or 2-2-0 0o puffins.
ROT CHORD 2x4 SP M 30 BOT CHORD
Rigid ceiling directly applied or 3-11-11 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (Itolaze) 2=1312/0-8-0, 9=1312/03-0
Max Horz 2=-129(LC 8)
Max Uplift 2=-803(LC 10), 9>803(LC 10)
FORCES. gla) - Max Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-5488/3444, 3-4=-5117/3183, 4-5=-3911/2497, 5-6=-2576/1770, 6-7= 2586/1779,
7-8=-2663/1762, 8-9= 3021/1971
BOT CHORD 2-13=3143/5224, 12-13_ 1956/3292, 11.12=-1369/2481, 9-11= I705/2827
WEBS 3-13=-396/420, 4-13=-1028/1721, 5-13=-300/797, 5-12=-894/601, 6-12=-265/263,
7-12=-294/391, 7-11=374/691, 8-11=-535/502
NOTES -
I) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=341t; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 31-73, Exterior(2) 31-7-3
to 35-0-0 zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water pending.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Bearing at joint(s) 2 considers parallel to grain value using ANSVTPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 1001b uplift at joint(s) except (jt=lb)
2=803, 9=803.
Thomas A. Albani PE N6.39390
MTek USA, Inc. FL Cad 6634
6904 Parke East Blvd. Tampa FL 33610
Date;
February 21,2018
OWAFN/NG- VerhydeslgnparamerarsmdBEAONOTES ON THISAND INCLUDED Ar EKBEFERANCEPAGEMR74Mmv. fONJlla15BEFORE USE
Design valid for use only with Miele® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate itrIs design Into fie overall
buiidingdeegn. Brocing Indicated is to prevent budding of Individual truss web and/or chord members only. Additional temporary and bracing
M!Tek*
permanent
Is clwoys required for stoblilty and to prevent collapse with possible persond injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and tmas systems seeANSVIPII Qualify Cmodo, D56419 and SCSI Building Component
69" Perks East Blvd.
Safsty Informutionovarabie from Truss Plate Invfifule, 218 N. fee Sheet Sure 312. Alexandria, VA 22314,
Tampa, FL 33610
Job
Truss
Truss Type
City
Ply
62' Grand Carlton III with porch
T13302395
M11323
A9
HIP
1
i
Job Reference (optional)
unamoers use, ma,., OR rierce, rL
4.00 12
o.tauaoep amv muee muusme>, ina. xveureuu 14.
4x4 = 3x4 = 2x3 II 08 =
4 24 525 26 6 27 7
Scale=-1:58.6
w m
3x5 = 3.8 = 3x6 = axis = 1.6 = 3x4 = 3x5 C
10-0-0 20-4-0 2a-D-o F 34-a0
to-n-n tn-a-n a -an tn.an
Plate Offsets (X Y)—
[2:0-0-14 Edoe][7:0-5-4 0-2-0] [9:0-3-14
0-1-8]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (too)
Udell
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.35
Vert(LL)
-0.18. 11-21
>917
360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.54
Vert(CT)
-0.3811-21
>432
240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.89
Horz(CT)
0.02 13
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Mainz -MS
Weight: 156 lb FT=O%
LUMBER- BRACING -
TOP CHORD 2x4SP M 30 TOP CHORD
BOT CHORD 2x4 SP M 30 BOT CHORD
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 2=663/0-8-0, 9=346/0-8-0, 13=1616/0-8-0
Max Horz 2=109(LC 9)
Max Uplift 2=-430(LC 10). 9=-249(LC 10), 13=-928(LC 10)
Max Gmv 2=685(LC 19), 9=386(LC 20), 13=1616(LC 1)
FORCES. (lb) -Max. CompJMax. Ten. -Aft forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1275/1025, 3-4=-9137708, 4-5=-8291705, 5-6=-565/807, 6-7=-565/807,
7-8=-104/278, 8-9=-341/235
BOT CHORD 2-15=-836/1187, 13-15=-34/309, 11-13=-256/348, 9-11=-124/304
WEBS 3-15=-425/501, 5-15=- 44/665, 5-13=-1215/1079, 6-13=-264/300,7-11=-255/396,
8-11=-461/521,.7-13=-837/703
Structural wood sheathing directly applied or 5-11-9 oc pudins.
Rigid ceiling directly applied or 6-0-0 oc bracing.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6U; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Intedor(1) 2-4-13 to 5-2-5, Extedor(2) 5-2-5 to
10-0-0, Interior(l) 14-9-11 to 19-2-5, Extedor(2) 24-0-0 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water pending.
4) This truss has been designed fora 10.0 psf bottom chord live load nonconcument with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100lb uplift at joint(s) except Qt=lb)
2=430, 9=249, 13=928.
Thomas A Alban! PE No.39380
MTek USA, Inc. FL Cart 6834
fi904 Parke East Blvd. Tampa FL 33610
Date:
February 21,2018
Q WINNING -Verify des/SOPerameterserd READ NOTES ON THISAND INCLUDED AMEKREFERANCEPAGEMO-7473 V. 10U 20f5REFORE USE
Design valid for use only with MiTeM connectors. itTh6 design Is bated only upon parameters shown and Is for an Individual building component, not
��-
a puss system. Before use, ire building designer must verty the applicability of design parameters and properly Incorporate this design Into me overall
buiidingdesign.Bracing indicated atoprevent buckling oflndiva ltrusweboratorchordmembersonly. Additional temporary and permanent bracing
is always requlred for stability and to prevent collapse with possible personal injury and properly damage, For general guidonce regarding the
fobricaflon, storage. delivery, erection and bracing of trusses and true systems seeANSVr1`I7 Guolpy Cmetb. D55419 and SCSI Suldhp Component
South,Informoibrrrvalloble horn Truss Plate Institute, 218 N. Lee Street, Sulie 312. Alexandrla, VA 22314.
MiTek-
69M Parke East Blvd.
Tampa, FL 33610
Job
Truss
Tnsss Type
Oty
Ply
62' Grand Canton III with porch
T13302396
M11323
GRA
HIP
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
I W
d
TOP CHORD -MUST -BE BRACED BY EN"ACKS,- -
ROOF DIAPHRAGM, OR PROPERLY CONNECTED
PURLINS AS SPECIFIED.
8.130 s Sep 15 2017 MiTek Industries, Inc. Wed Feb 21 14:19:59 2018
Scale=1:60.6
3 = 3.6 II 3x6 = 6xa = 3x6 = 6xa = 44 =
axe =
e-o-o na-1 1B-6-o 26-0-0 3a-o-o
e-o-o 1 3-1-1 1 7-4-15 1 7-6-0
N
3N7
1d
Plate Offsets (X Y)--
[2:0.2-2 Edgel r3:0-3-8 Edge] [21:0-0-8
Edgel 124:0-3-8 0-3-0][27:0-3-8 0-3-0]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc)
Well
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1,25
TC 0.91
Vert(LL)
0.20 24-35
>914
360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.57
Vert(CT)
-0.24 29-32
>552
240
BCLL 0.0 '
Rep Stress Incr NO,
WB 0.98
Horz(CT)
0.02 22
n/a
n/a
BCDL 10.0
Code FBC2017/rP12014
Matrix -MS
Weight: 194 lb FT=O%
LUMBER-
BRACING -
TOP CHORD
2x4 SP M 30
TOP CHORD Structural wood sheathing directly applied or 4-2-5 oc puffins.
BOT CHORD
2x4 SP M 30
Except:
WEBS
2x4 SP No.3
1 Row at midpt B-21
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
JOINTS 1 Brace at JI(s): 7, 8, 19, 17, 14
REACTIONS.
All bearings 0-8-0.
(Ib) -
Max Horz 2=-179(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) except
2=-351(LC 8). 27= 1168(LC 8), 26=-1495(LC 8).
22=-625(LC 8)
Max Grav All reactions 250 lb or less at joint(s) except 2=487(LC 17), 27=2232(LC 13), 26=2929(LC 14).
22=984(LC 14)
FORCES. (Ib) - Max Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 23.=-621/387, 3-5=-304/838, 5-7=-588/1209, 7-8=-588/1209, 8-12=-588/1209,
12-13=-588/1209,13-15=-588/1209,15-16=-588/1209,16-18=-588/1209,
18-20=-2230/1280, 20-21=-2230/1280, 21-22= 2271/1263, 6-9=-126/305, 9-11=-106/363,
11-14=-193/412,14-17=-94/271, 19-21=-143/272
BOT CHORD 2-29= 247/677, 27-29=-189/540, 26-27=-779/446, 24-26=-411/653, 22-24=-1083/2108
WEBS 3-29=-500/1176, 3-27— 1766/911, 5-27=-748/622, 5-26=-546/351, 13-26=946/617,
18-26=-2412/1474,18-24=-846/1780,21-24=-35/351,4-5=-608/514,19-20=-335/305,
14-15=-556/407.11-12=-254/54
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2pst BCDL=3.Opsh h=14ft; B=52ft; L=3411; eave :6ff; Cat.
II; E1p C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate gdp DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are 2x3 MT20 unless otherwise indicated.
5) This truss has been designed for a 10.0 pat bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-M wide
Will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 351 Ib uplift at joint 2, 116B lb uplift at
joint 27,1495 lb uplift at joint 26 and 62516 uplift at joint 22.
8) Girder carries hip end with a-0-0 end setback.
9) Graphical pudin representation does not depict the size or the orientation of the puffin along the top and/or bottom chord.
10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 967 lb down and 461 lb up at
26-0-0, and 967lb down and 461 Ib up at B-0-0 on bottom chord. The designtselection of such connection device(s) is the
responsibility of others.
11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
Thomas A Albani PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
February 21,2018
ndard
A WARNING-Vedtydeslgnp4/amefersend READNOTES ON 7MSANDWCLUDEDMn KREFERANCEPAGEMR74Mmv 1a 016BEFOREUSE.
Design valid forum oNywith M706 connectors. This design Is based only upon parametersshown, and Is for on Individual bW ding component. not
a truss system. Before use, the bukd1r g designer must veefy the applicability of coach parameters and property Incorporate this design Into the overall
building design. &acing Indicated 6 to prevent buckling of InOlviduol truss web and/or chord members only. Additional temporary and permanent bracing
Is always required for stablllry and to prevent collapse with passible personal Injury and property damage. For general guldonce regarding the
fabecation, storage. delivery, erection and bracing of trusses and truss systems, meANSVIPit Quo" CdLda, DSB419 and BM Building Component
Saf Informationavolloble from Truss Plate Institute. 218 N. Lee street Suite 312, Alexontlrlo. VA 22314.
��-
MiTek-
6909 Parka East Blvd.
Tampa, FL 33610
Job
Truss
Truss Type
Ott,
Ply
Grand Carlton III with porch
T73302396
M11323
GRA
HIP
1
1
�6Z
'
Job Reference (optional)
Chambers Thus, Inc., Fort Pierce, FL
LOAD CASE(S) Standard
1) Dead+ Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Vert: 1-3=-54, 21-23=-54, 29-30=-20, 24-29=-47(F=-27), 24-33=-20, 3-11=-1
Concentrated Loads (Ib)
Vert: 29=-641(F)24=-641(F)
8.130 s Sep 15 2017 MIek Industries, Inc. Wed Feb 21 14:19:59 2018 Page 2
I D:_elC1 cxC3izW?huls?ypJyuFUK-XSEZg9LDhnOwiDOcO6cpTEfaGKGyBpOvzlMFbvuKE
O WANNINO-Veritydesfgnpawmefeo MdNEAR NOTES ON MEANDINCLUDEOMgEKNEFENANCEPAGEMIP74MMK. 10N 0155EFO11EUSE
valid for use any with MBek® connectors. This design Is based only upon parameters shown. and Is for an Individual building component, not
Nat
a Muss system. Before use, the building designer must verify Me oppllcabllily of design parameters and properly Incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse wth possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery erection and bracing of cusses and truss systems. seeANSUVII Quality CrBr.M, DSB49 and SCSI Building Component
69M Parke East BNtl.
Sabin NformaBornvo0oble Mom Taus Rate Institute. 218 N. Lee Sheet Suite 312, Alexandre, VA 22314.
Tampa, FL M610
Job
Truss
Truss Type
Oty
Ply
Grand Carlton III with porch
T73302397
M11323
GRB
HIP
1
1
�62'
Job Reference (optional)
Chambers Truss, Inc., Fad Pierce, FL 8.130s bep Ib2U1/ MI I eK Industries, Inc. wed Feb i ia:eu:ul zuio rage i
ID:SrRaEyyrgO4M78G4raW BLW yuFUJ-TgMKFrNTDOedyW 4NkR84uuK1 w4_706XhNGETJTziuKC
1-0-q 8-"0 1&8-0 17-0-0 20-4-0 26-0-0 34-0-0 35-0-0
h-0-0 8-0.0 5-8-0 3.4-0 34-0 5-8-0 F 8-0-0 1-0-0
Scale=1:58.6
5x8 MT18HS= 4x10 =
5z8 MT18HS =
4.00 12 2z3 11 46 = 2x3 I I
1;4
4z6 =
3.6 II 5x6 = 6x12 =
6x12 = 1x6 = 3x6 II
4z6
DIu2
LOADING (psf)
SPACING-
2-0-0
CS1.
OEFL
in (roc) Vdefl Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.80
Vert(ILL)
0.22 16-19 >999 360
MT20
244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.68
Ved(CT)-0.3016-19
>820 240
MT18HS
244/190
BCLL 0.0 '
Rep Stress Incr
NO
WB 0.90
Horz(CT)
0.06 9 Na n/a
BCDL 10.0
Code FBC2017/rP12014
Matrix -MS
Weight: 1531b
FT=0
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 3-1-14
oc pudins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 53-14 oc bracing.
WEBS 2x4 SP No.3 *Except'
WEBS
1 Row at midpt 3-14,
8-13, 6-13
4-14,7-13: 2x6 SP No.2
REACTIONS. (lb/size) 2=1269/0-8-0, 13=4057/0-8-0, 9=474/0-8-0
Max Holz 2=90(LC 7)
Max Uplift 2=-853(LC 8), 13=-2590(LC 8), 9=345(LC 8)
Max Gray 2=1451(LC 13), 13=4743(LC 15), 9=528(LC 14)
FORCES. fib) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown.
TOP CHORD 2-3=-3625/1950, 3-4=-2080/1236, 4£=-2080/1236, 6-7= 1296/2589, 7-8=-1296/2589,
8-9=-751/370
BOT CHORD 2-16=-1729/3460, 14-16=-1753/3525, 11-13=-262/733, 9-11=-241/668
WEBS 3-16=-435/1209, 3-14=-15521774,4-14=-837/691, 7-13=-878/713, 8-13=-3635/1919,
8-11=-432/1204,6-14=-1453/2814, 6-13=-3198/1807
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water pending.
4) All plates are MT20 plates unless otherwise indicated.
5) This Muss has been designed fora 10.0 psf bottom chord live load nonconcument with any other live loads.
6) • This truss has been designed for a live load of 20.Opsf an the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 8531b uplift at joint 2, 2590 lb uplift at
joint 13 and 3451b uplift at joint 9.
8) Girder carries hip end with 8-0-0 end setback.
9) Hangeds) or other connection device(s) shall be provided sufficient to support concentrated load(s) 967 Ib down and 461 lb up at
26-", and 967 lb down and 461 He up at 8-0-0 on bottom chord. The desigrdselection of such connection device(s) is the
responsibility of others.
10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead+ Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pit)
Vert: 1-3=-54, 3-8=-131(F=-77), 8-10=-54, 16-17=20, 11-16=-49(F=-29), 11-20=-20
Thomas A. Alban! PE No.39380
MiTek USA, Inc. FL Cart 6634
61 Parke East Blvd. Tampa FL 3361D
Date:
February 21,2018
A WARNING- Verity Eeslgnparamerera andREAD NOTES ON TNISANDINCLUDED MREKREFERANCE PAGEMIP74mrsv.?oVJc!015BEFOREUSE
Design valid for use only with MRekG connectors. This design is based only upon parameters shown, and Is for on Individual building component, not
��-
a truss system. Before use, Me building designer must verify Me applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual Miss web and/or chord members only.. Additional temporary and permanent bracing
MiTek'
Is always required for stabrity and to prevent collapse with possible personal Injury and property damage. For general guidance regarding Me
69M Palle East ISafety
fabrication storage, delivery, erection and bracing of busses and fruss systems saeAN51/iPll QYaIMMyy Cmsdo, D5549 and BCSI Building Component
Mformatbmvoiloble from Truss Plate Institute, 218 N. Lee SfreeL Suite 312. Alexontlrlo, VA 22314.
Tampa, FL 336t o
Job
Truss
Truss Type
Gty
Ply
Grand Carlton III with porch
T73302397
M11323
GRB
HIP
1
1
�6T
Job Reference o lional
Chambers Truss, Inc., Fort Pierce, FL 8.130 a Sep 15 2017 MiTek Industries, Inc. Wed Feb 21 14:20:01 2018 Page 2
ID:SrRaEyyrg04M78G4raWBLWyuFUJ-TgMKFrNTDOedyW4NkR84uuK1 w4 ?OBKhNGETJTaUKC
LOAD CASE(S) Standard
Concentrated Loads (lb)
V e rtA 6=-841(F)-11=-641(F )
QWARNING- Ved1ydeslgnparameters4nd READ NOTES ON TN/SANO INCLOOEO MITEKREFERANCEPAGEMIF74"mre 14,113aV15HEFORENSE
Design voila for use only with MBeM connectors. This tleslBn Is based only upon parameters shown, and 6 for an Intllvitlual building component. not
a truss system. Before use, the building designer must verify me oppllcabllliy of de4n parameters and property Incorporate this tleslBn Into me overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
Is always required for stability and to prevent collapse wm possible perwnol Injury and property damage. For general guidance regarding me
fobdCatiCA storage. delivery, creation and bracing of trusses and truss system% WeANS1/IPII Gua�y CdteM, DS349 and BCSI BuildingGmpanenl
Sabin asformotbrwollobie from Truss Plate Institute. 218 N. Lee Sheaf, SUHe 312. Alexontltla, VA 22314.
MiTek'
6904 Perko East Bind.
Tampa, FL M610
Job
Truss
Truss Type
Ory
Ply
62' Grand Calton III with porch
T13302398
M11323
J2
MONO TRUSS
8
1
Job Reference o tional
waomers cuss, mu., on tierce, rL
2
3x4 -
4.00 12
ID:xl?zSlzTbJCDIIrGPH1 OukyuFUI-TgMKFrNTDOedyW 4NkR84uuKBb47aOKfhNGETJTz1uKC
LOADING lost)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/defl
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC
0.18
Ve art
-0.00
7
>999
360
TCDL TO
Lumber DOL
1.25
BC
0.07
Vert(CT)
-0.00
7
>999
240
BCLL 0.0 '
Rep Stress Incr
YES
WB
0.00
Horz(CT)
-0.00
3
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
REACTIONS. lialsize) 3=38/Mechanical, 2=141/0-8-0, 4=22/Mechanical
Max Horz 2=67(LC 10)
Max Uplift 3=-28(LC 10), 2=-136(LC 10), 4=-0(LC 7)
Max Gray 3=39(LC 15), 2=141(LC 1), 4=31(LC 3)
FORCES. (Ib) - Max. Comp./Max Ten. -All forces 250 (lb) or less except when shown.
4
Scale = 1:7.8
PLATES GRIP
MT20 2441190
Weight: 8lb FT=0
BRACING -
TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opst h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exier or(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 28 lb uplift at joint 3, 136111 uplift at joint
2 and 3 to uplift at joint 4.
Thomas A Albani PE No.39380
MTek USA, Inc. FL Cad 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
February 21,2018
QWARNING-Yentytleslgnparemefemand READ NOTES ON TN/SAND INCLUDED MTEKREFERANCEPAGEMM17473.- fava2p15BEFORE USE
Design valid for use only Wth MiTek®connectors. lhb design Is based only upon parameters shown, and Is for on Individual building component not
��-
a truss system. Before use. the building designer musiverify the applicability of design parameters antl properly incorporate this design Into me overall
bullding design, Bracing indicated is to buckling hdlvlduol lass web and/or chord members only, Additional temporary and permanent bracing
MTek
prevent of
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guldance regarding fie
Parke East Blvd.
East
fobrlcatlon, storage. dallvery, erection and bracing of trusses and truss systems, seeANSUIPil Quality CMMa. DS649 and lCSI Bidding
g Component
Saby N/omlalbnwaJable from Truss Plate Institute, 218 N. Lee Street Suite 312, Alexandria, VA 22314.
Tampa, FL
P
Job
Truss
Truss Type
Ply
62'GrandCadtonIIIwithporchT73302399
M11323
J4
MONO TRUSS
r
1
Job Reference (optional)
unamoers r ruts, Mo., ran I' erce, I-L
3x4 =
o. rou a aep m .... mi r nrt inuusmes, inc. urea reu a ,v.m.oc m r o
LOADING (psf)
SPACING•
2-0-0
CS'.
DEFL.
in
(too)
Well
Ud
TCLL 2%
Plate Gdp DOL
1.25
TC 0.39
Vert(LL)
0.02
4-7
>999
360
TCDL 7.0
Lumber DOL
1.25
BC 0.37
Vert(CT)
-0.02
4-7
>999
240
BCLL 0.0 '
Rep Stress Incr
YES
WE 0.00
Horz(CT)
-0.00
3
n/a
n/a
BCDL 10.0
Code FBC2017/rP12014
Mat
LUMBER -
TOP CHORD 2x4 SP No.3
SOT CHORD 2x4 SP No.3
REACTIONS. (lb/size) 3=90/Mechanical, 2=207/0-8-0, 4=50/Mechanical
Max Horz 2=104(LC 10)
Max Uplift 3=-80(LC 10), 2_ 161(LC 10), 4= 7(LC 10)
Max Grav 3=900LC 1). 2=207(LC 1), 4=69(LC 3)
FORCES. (Ib) - Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
PLATES GRIP
MT20 244/190
Weight: 14 lb FT=0
BRACING -
TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc puffins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2pst BCDL=3.Opst h=14ft; B=52ft; L=34ft; save=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 80 lb uplift at joint 3, 161 lb uplift at joint
2 and 7lbuplift at joint 4.
Thomas A Albanf PE No.39380
MTek USA, Inc. FL Chat 0634
6904 Parke East Blvd. Tampa FL 33610
Date:
February 21,2018
QWARNING-Vsfiry design pa1amel4rsend READ NOTES ON THISAND INCLUDED MREKREFERANCEPAGEMIF74T3 rev. 1GVV?015eEFOREUSE
Design valid for use only with MRekO connectors, This design Is based only upon parameters shown, and Is for an IndMduol bulidiing component, not
a truss system. Before use, the building designer must verify the apprwbllay of design parameters and properly Incorporate this design Into the overall
building design Bracing Indicated b to prevent bucNhg of individual truss web and/or chord members only. Additional temporary and permanent bracing
6 always required for stability and to prevent collapse with potable personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery erection antl bracing of trusses and huss systems M MSVIPII Quaff CMedo. DSB49 and BCSt Bulding Component
Safety Informatbrgvolloble from Truss Nate Institute, 218 N. Lee Sheet. Suite312 Alexandria. VA 22314.
MiTek' -
6904 Parka East Bind.
Tampa, FL 33610
Job
Truss
Truss Type
Oty
Ply
62' Grand Carlton III with porch
T73302400
M11323
J6
MONO TRUSS
8
1
Jab Reference (optional)
GnamDers I russ, Inc.. Fort PlerCe, I-L
3x4 =
8.13u s Sep 15'2U17 MI I ex InauMnes, Inc. Wed Fee 21 142U:03 2U18 Pagel
6 0.0
LOADING (psq
SPACING-
2-0-0
CS].
DEFL
in
(loc)
Vdefl
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.36
Vert(LL)
0.11
4-7
>629
360
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.83
Vert(CT)
-0.12
4-7
>617
240
BCLL 0.0 '
Rep Stress [net
YES
WB 0.00
Horc(CT)
-0.00
3
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
Weight: 20 lb FT=O%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins.
BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 3=145/Mechanical, 2=279/0-8-0, 4=71/Mechanical
Max Ham 2=142(LC 10)
Max Uplift 3=-131(LC 10), 2— 194(LC 10), 4=-8(LC 10)
Max Grav 3=145(LC 1), 2=279(LC 1), 4=102(LC 3)
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2pst BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exledor(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 131 Ib uplift at joint 3, 194 lb uplift at
joint 2 and 8lb uplift at joint 4.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Ced 6834
6904 Parke East Blvd. Tampa FL 33610
Date:
February 21,2018
NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE MIF7473ftx 1D=Ur15 BEFORE USE
a
Welk'
69M Parka East Blvd.
Tampa, FL M610
Job
Truss
Truss Type
Oty
Ply
62' Grand Carlton III with porch
T73302401
M11323
JB
MONO TRUSS
20
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
4.00 12
3x4 cc
8.130 s Sep 15 2017 MiTek Industries, Inc. Wed Feb 21 14:20:04 2018 Page 1
ID.tP6jtzLj7xSx_c fXi4uz9yuFUG-uP1 SutPMWJOCp—pyPZnWXybuH5UdhP73ES7woziuK9
Scale=1:17.4
8-0-0
Plate Offsets (X Y)—
(2:0-3-14 0-1-81
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL. in
(loc) Well Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.62
Vert(LL) 0.26
4-7 >367 360
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.38
Vert(CT) -0.30
4-7 >319 240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.00
Horz(CT) -0.00
3 n/a Ida
BCDL 10.0
Code FBC2017/TP12014
Main% -MP
Weight: .261b FT=O%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc puriins.
BOT CHORD 2x4 SP M 31
BOT CHORD
Rigid ceiling directly applied or 10-M no bracing.
REACTIONS. (Ib/size) 3=188/Mechanical, 2=352/0-8-0, 4=103/Mechanical
Max Horz 2=180(LC 10)
Max Uplift 3=-175(LC 10), 2=-228(LC 10), 4=-15(LC 10)
Max Grav 3=188(LC 1), 2=352(LC 1), 4=145(LC 3)
FORCES. (lb) - Matt Comp./MaK Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=Gft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 3-1-13, Exterior(2) 3-1-13
to 7-11-8 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 175 Ib uplift at joint 3, 228 lb uplift at
joint 2 and 151b uplift at joint 4.
Thomas A Alban! PE No.39380
MiTek USA, Inc. FL Cart 6834
8904 Parke East Blvd. Tampa FL 33610
Date:
February 21,2018
Q WAIll Varitydeelgnparametersend NEAONOTES ON 7NISANO INCLUDED)RIEKNEFERANCEPAGEMA-747atev. IoTst2a15aEOSE USE
Oes[gn valid for use only wim MlTeld]) connectom fib design Is based only upon parameters shown. and is for an individual building component not
a truss system. Before use, me building designer must verify me opplicobiilly of design parameters and properly Inca porote this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding me
fabrication, storage, delivery. erection and bracing of Masses and truss systems, seeANS"ll Quality Cmrrda, DSB49 and BCSI Building Component
6904 Parke East 9Nd.
Safety Infarmatianc noble from Truss Plate Insfitote, 218 N. tee Sheet. Suite 312, Nexandri¢ VA 22314,
Tampa, FL 33810
Job
Truss
Truss Type
Oty,
Ply
Calton III with porchT73302402
M11323
KJB
MONO TRUSS
4
1
F62G,—anl
eference o lional
chambers Thus, Inc., Fort Pierce, FL
8.130 s Sep 15 2017 MiTek Industries, Inc. Wed Feb 21 14:20:05 2018 Page 1
ID:Lcg54J7LuEancmZr4Qb7WMyuFUF-Mcbr5C0_Hd83Q8O9zHD02kUrohRsMI VGHuCgSEziuK8
Scale=1:20.3
3x4 = 5
3x4 =
7-34
3-11-12
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) Well L/d
PLATES GRIP
TOLL 20.0
Plate Grip DOL 1.25
TO 0.29
Vert(LL) 0.07
7-10 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.30
Vert(CT) -0.12
7-10 >999 240
BCLL 0.0 '
Rep Stress ]nor NO
WB 0.46
Horz(CT) 0.02
6 We n/a
BCDL 10.0
Code FBC2017ITP12014
Matrix -MS
Weight: 44 lb FT=O%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc puffins.
BOT CHORD 2x4 SO M 30
BOT CHORD
Rigid ceiling directly applied or 8-9-6 oc bracing.
WEBS 2x4 SO No.3
REACTIONS. (lb/size) 4=201/Mechanical, 2=466/0-11-5, 6=576/Mechanical
Max Horz 2=244(LC 8)
Max Uplift 4=-205(LC 8), 2=-305(LC 8), 6=-286(LC 8)
Max Grav 4=245(LC 13), 2=466FLC 1), 6=590(LC 13)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3_ 1151/523
BOT CHORD 2-7=-687/1126, 6-7=-687/1126
WEBS 3-7=0/330, 3-6=-1236/755
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=1411; B=52ft; L=34ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed fora 10.0 psf bottom chord live load nonconcument with any other live loads.
3) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
Wit fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 205lb uplift at joint 4, 305 lb uplift at
joint 2 and 286 lb uplift at joint 6.
6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front F) or back (B).
LOAD CASES) Standard
1) Dead+ Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-2=-54
Trapezoidal Loads (pit)
Vert: 2=0(F=27, B=27)4o-4=-152(F=-49, B=-49), 8=0(F=10, B=10)-to-5=-56(F=-18, B=-18)
Thomas A. Alban! PE No.39380
MTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
February 21,2018
OWARNNG-Verity Ees/gnp---h..ndR RD NOTES ONTHISANDMCLUDEDMREKBEFENANCEPAGEMI474MMI laM. 01SBEFONE USE
Design valid for use only with MTe 0 connectors. This, design Is based only upon parameters shown, and Is for an Individual bulding component, not
a truss system. Before use, the bulding deAgner must verify the appllcablllty of design parameters and propelly Incorporate this design Into the overall
bufldingdesign. Bracing Indicated a to prevent bucklingofIndividual insssweb and/or chord members only. Additional temporary and pennanentbracing
MiTek'
Is always requked for stablllly and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabdcaeon, storage, delivery, erection and bracing of trusses and Ines systems, seeANSVIPII Quality CMelo, DS049 and BCSI Building component
Safety Informationcvallable from Truss Plate Institute.
6904 Parke East Blvd.
Tampa, FL
218 N. Lee Street, Sulte 312, Alexandrla VA 22314,
33610
symbols
PLATE LOCATION
n4�
AND ORIENTATION
" Center plate on joint unless x, y
offsets are indicated.
Dimensions are In ft-in-sixteenths.
Apply plates to both sides of truss
and fully embed teeth.
1/ r
0-1
' Id
For 4 x 2 orientation, locate
Numbering System
6u48 dimensions shown In ft-In-sixteenths
I I (Drawings not to scale)
1 TOP CHORDS 3
Cl-2 cza
Gra4may
OU,3O
O VX1
asx°P U
0
General Safety Notes
Failure to Follow Could Cause Property
Damage or Personal Injury
1. Additional stability bracing for truss system, e.g.
diagonal or X-brocing. Is always required. See BCSI.
2. Truss bracing must be designed by an engineer. For
wide truss spacing, Individual lateral braces themselves
require bracing, or alternative Tor I
bracing should be considered.
3. Never exceed the design loading shown and never
stack materials on Inadequately braced trusses.
4. Provide copies of this truss design to the building
designer, erection supervisor, property owner and
Oa
c�a cat csa
plates 0-'fie" from outside
BOTTOM CHORDS
all other Interested parties,
edge of truss.
8 7 6 5
5. Cut members to bear tightly against each other.
6. Place plates on each face of truss at each
This symbol Indicates the
JOINTS ARE GENERALLY NUMBEREDAETTERED CLOCKWISE
Joint and embed fully. Knots and wane otjoint
required direction of slots in
AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO
locations are regulated by ANSI/IPI 1.
connector plates.
THE LEFT.
7. Design assumes trusses will be suitably protected from
Plate lac
lion decals available in MTek 20/20
CHORDS AND WEBS ARE IDENTIFIED BY END JOINT
the environment In accord with ANSI/rPI 1.
software
rupon request.
NUMBERSAETTERS.
8. Unless otherwise noted, moisture content of lumber
shall not exceed 19%at time of fabrication.
PLATE SQ
PRODUCT CODE APPROVALS
9. Unless expressly noted, this design is not applicable for
ICC-ES Reports:
use with fire retardant, preservative treated, or green lumber.
The first dimension Is the plate
10. Camber B a non-structural consideration and is the
4 x 4
width measured perpendicular
ESR-1311, ESR-1352, ESR1988
responsibility of truss fabricator. General practice is to
to slots. Second dimension Is
ER-3907, ESR-2362, ESR-1397, ESR-3282
camber for dead load deflection.
the length parallel to slots.
11. Plate type, sae, orientation and location dimensions
Indicated are minimum plating requirements.
LATERAL BRACING
LOCATION
12. Lumber used shall be of the species and size, and
17
Indicated by symbol shown and/or
Trusses are designed for wind loads in the plane of the
in all respects, equal to or better than that
specified.
by text in the bracing section of the
truss unless otherwise shown.
13. Top chords must be sheathed or purlins provided at
output. Use T or I bracing
spacing Indicated on design.
if Indicated.
Lumber design values are in accordance with ANSI[TPI 1
section 6.3 These truss designs rely on lumber values
14 Bottom chords require lateral bracing at 10 ft. spacing.
or less, if no calling Is Installed, unless otherwise noted.
BEARING
established by others.
15. Connections not shown are the responsibility of others.
Indicates location where bearings
16. Do not cut or alter truss member or plate without prior
l
(supports) occur. Icons vary but
© 2012 MITek® All Rights Reserved
approval of an engineer.
reaction section Indicates joint
number where bearings occur.
17. Install and load vertically unless Indicated otherwise.
Min size shown Is for crushing only.
��e
18. Use of green or treated lumber may pose unacceptable
environmental, health or performance risks. Consult with
Industry Standards:
project engineer before use.
ANSI/TPI1:
National Design Specification for Metal
19. Review all portions of this design (front, back, words
Plate Connected Wood Truss Construction.
and pictures) before use. Reviewing pictures alone
DSB-89:
Design Standard for Bracing.
®
is not sufficient.
BCSI:
Building Component Safety Information,
M
20. Design assumes manufacture in accordance with
Guide to Good Practice for Handling,
IT�,\11(—
ANSI/rPi l Quality Criteria.
Installing & Bracing of Metal Plate
Connected Wood Trusses.
MITek Engineering Reference Sheet: Mll-7473 rev. 10/03/2015