Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR. BY Street: N­y">';.. �2`� 4� Permit Office: ST. LUCIE COUNTY St Lucie City, State, Zip: FT. PIERCE, FL, Permit Number: county t y Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY Design Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1442.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft' b. Frame - Wood, Adjacent R=11.0 192.00 ft' 3. Number of units, if multiple family 1 c. N/A R= fF 4. Number of Bedrooms 2 d. N/A R= fF 5. Is this a worst case? Yes 10. Ceiling Types (1446.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1446.00 ft' 6. Conditioned floor area above grade 1446 b. N/A R= ft' Conditioned floor area below grade (ft') 0 _ 11. Ducts R ft' 7. Windows(141.3 sgft.) Description Area a. Sup: Attic, Rat: Attic, AH: Attic 6 250 a. U-Factor: Sgl, U=0.36 101.25 ft' SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 40.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 34.8 SEER:15.00 c. U-Factor: WA fP SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: NIA ft' a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.239 14. Hot water systems 8. Floor Types (1445.5 sgft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft' b. Conservation features EF: 0.970 b. WA R= ft' None c. NIA R= ft' 15. Credits Pstat Glass/Floor Area: 0.098 Total Proposed Modified Loads: 47.17 PASS Total Baseline Loads: 48.08 1 hereby certify that the plans and specifications covered by Review of the plans and S?g18 this calculation are in compliance with the Florida Energy specifications covered by this pFgHE ti , = O� Code. calculation indicates compliance with the Florida Energy Code. f. rnu �s o: '; ••• „ O PREPA Y: Before construction is completed r DATE: this building will be inspected for RV y O V ll compliance with Section 553.908 c . tr I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. G'0 WE �O OWNER/�EN�\� ��� BUILDING OFFICIAL: DATE:11 DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factorysealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FILE Copy 4/17/2018 4:06 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 PROJECT Title: WYNNE THE GRAND CARL Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1446 # Owner Name: - WYNNE BUILDING CROP Total stories: 1 _ _ _Lot Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180 Street: Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1446 11568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 301 2408 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M. BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 It 0 301 ft' ____ 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft' — 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft' _- 0 1 0 4Slab-On-Grade Edge Insulatio KITCHEN 1 ft 0 192 ft' 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 fF — 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 It 0 203.5 ft' -_ 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft' 0 1 0 4/1712018 4:06 PM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 FLOORS # Floor Type, Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab-bn-Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft' ___ 0_ 1 _ 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft' ___ 0 1 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1524ft' 240ft' Light 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1446 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 301 ft' 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft' 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft' 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft' 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft' 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft' 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 fF 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft' 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft' 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NE=>SW Exterior Concrete Block - Ext Ins®EDROOM 4.1 10 0 8 0 80.0 ft' 0 0 0.6 0 2 SW=>NE Exterior Concrete Block - Ext InsQEDROOM 4.1 28 0 8 0 224.0 ft' 0 0 0.6 0 3 NW=>SE Exterior Concrete Block - Ext InsiHEDROOM 4.1 14 0 8 0 112.0 ft' 0 0 0.6 0 4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft' 0 0 0.6 0 5 NE=>SW Exterior Concrete Block- Ext Insul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.6 0 6 NE=>SW Exterior Concrete Block - Ext InfiffDROOM 2 4.1 16 0 8 0 128.0 ft' 0 0 0.6 0 _ 7 SE=>NW Exterior Concrete Block - Ext IndI&DROOM 2 4.1 10 0 8 0 80.0 ft' 0 0 0.6 0 8 S=>N Exterior Concrete Block - Ext In9;ffDROOM 2 4.1 4 3 8 0 34.0 ft' 0 0 0.6 0 9 SW=>NE Exterior Concrete Block - Ext InfiffDROOM 2 4.1 2 0 8 0 16.0 ft' 0 0 0.6 0 10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft' 0 0 0.6 0 _ 11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft' 0 0 0.6 0 12 SW=>NE Exterior Concrete Block - Ext InsdfAUNDRY 4.1 6 0 8 0 48.0 ft' 0 0 0.6 0 13 NE=>SW Exterior Concrete Block - Ext Ins REAT/DINI 4.1 26 0 8 0 208.0 ft' 0 0 0.6 0 14 NW=>SE Exterior Concrete Block - Ext Ins3REAT/DINI 4.1 20 0 8 0 160.0 ft' 0 0 0.6 0 15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft' 0.23 0.6 0 4/17/2018 4:06 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 DOORS # Omt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1—SE=>NW Insulated - ENTRY- - None .39 3 -1- 6 8 20.6 ft' WINDOWS Orientation shown is the entered orientation => chan ed to Worst Case. / Wall V # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW13 Metal 5 NW=>SE14 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes 0.36 0.25 N 32.9 ft' 1 ft 0 in 1 ft 4 in 0.36 0.25 N 6.9 ft' 1 ft 0 in 1 ft 4 in 0.36 0.25 N 24.0 ft' 6 ft 0 in 1 ft 4 in 0.36 0.25 N 37.5 T 1 ft 0 in 1 ft 4 in 0.65 0.21 N 40.0 ft' 8 ft 0 in 1 ft 4 in Drapes/blinds None None None Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft' 315 ft' 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1349.6 74.09 139.34 .2598 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None fP 4/1712018 4:06 PM EnergyGauge® USA- FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 DUCTS / — Supply — — Return — Air CFM 25 CFM25 HVAC # V # • Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 250 ft' Attic 65 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programabl[[eX]]Thermostat: Y Cf[eiling Fans: Venting Feb Feb Mar Mar Apr ApJan May Jun [X [ Jul [[ [X� Aug r[[ ]] Sep � ] L J Oct ov [[[[XX Dec [[X]] [ ]Jan l l txl r [ LX� Jun [ Jul [[ Aug LXJ [ Sep lXl [X� Nov [ ] Dec Thermostat Schedule: -HERS 2006 Reference - Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4/17/2018 4:06 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR. Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall eytp.nd behind nFning and wiring Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. In addition, inspection of log walls shall be in accordance with the provisions of ICC400. 4/17/2018 4:06 PM EnergyGauge® USA- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 FORM R406-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. , FT. PIERCE, FL, 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned Floor area (ft2) 7. Windows" Description a. U-Factor: SgI, U=0.36 SHGC: SHGC=0.25 b. U-Factor: SgI, U=0.65 SHGC: SHGC=0.21 c. U-Factor. WA SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: New (From -Plans) 9. Wall Types Insulation Area Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R=11.0 192.00 ft2 1 c. N/A R= ft2 2 d. N/A R= ft2 Yes 10. Ceiling Types Insulation Area a. Under Attic (Vented) R=30.0 1446.00 ft2 1446 b. N/A R= ft2 Area c. N/A R= ft2 101.25 ft2 11. Ducts R ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 250 40.00 ft2 12. Cooling systems kBtu/hr Efficiency ft2 a. Central Unit 34.8 SEER:15.00 ft2 13. Heating systems kBtu/hr Efficiency a. Electric Heat Pump 34.8 HSPF:8.50 3.832 ft. 0.239 8. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft2 b. N/A R= ft2 c. N/A R= ft2 14. Hot water systems a. Electric Cap: 40 gallons EF: 0.97 b. Conservation features None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: -� Date: Address of New HomeV-NN�j'Z�Q``c� City/FL Zip: Q�CQ 1;z�- \� . -3 `'l q 5 *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/17/2018 4:06 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 i Pro oe.. ummary - - wl•ightsoft Endre-House ,iS, QUICK CALCS, INC. 3;r T.. LUCIE LDI, FT..PIERCE, F134946 Pho;772."799 Faz 77246"799.. Eu¢9: PUICKCALCSSA Project Information For THE GRAND CARLTON WYNNE DEVELOPMENT, Fr...PIERCE, .FL Notes: ��� 1 Weather: Winter Design Conditions Outside db 42 � IF Inside db. 70 OF Design TD 28 OF 'Fort Pierce, FL; US Heating Summary Stricture 17848 Btuh Ducts 5654 Btuh' Central vent (0 cfm) 0 Btuh (none) . Humidification 0 Btuh Piping 0 Btuh Equipment load 23503 Btuh. Infiltration Method Simplified Construction quality Average Fireplaces 0 Area.(ftj Heating Coolingg. 1446 .1446 Volume (ft) 12511 12511 AirchargeWhour 0.5 M23 Equiv. AVF (cfm) 94 48 Heating. Equipment Summary Make Cartier• Trade CARRIER AIR CONDITIONING Model 25HBC536A•030 AHRI ref 7914585 Efficiency 8.5 HSPF Heating mpat Heating output 34600'_Btuh @ 47°F Temperature rise ',U IF Actual'air.flow.. 1160 cfm Air flow factor 0.049 cfmfBtuh Static pressure 0.5.0 in H2O Capacity balance point = 32 IF Backup: Input = 7 kW. Output = 23009 Btuh, 100 AFUE Job: Date: By: Summer Design Conditions Outside db - so IF Inside db 75 OF, Design T.D 15 OF Daily range L Relative humidity, 50 % Moisture difference 61 gdlb Sensible Cooling<Equipment:Load Sizing Structure 17520 Btuh Ducts 8536 Btuh Central vent (0 cfm)* 0 - Btuh (none) Blower 0 Stun Uas manufacturer's data n Ratelswing muluglier 0.95 Equipmenfsensibleload 24753 Stuh Laterif Cooling EgtApmen :Load Sizing. Structure 3203 'Btuh Ducts 2318 Btuh Central vent (0 cfm) 0Btuh (none). Equipment latent load 5521 Btuh Equipment total load 30274 Btuh Req. total capacity at 0.70 SHR 2.9 ton Cooling Equipment Summary ' Make Cartier Trade CARRIER AIR CONDITIONING Cond 25HBC536A'030' . Coil FX41)N(B;F)037 AHRI`ief 791458855 Efficiency 12.0 EER, 15'SEER Sensible; cooling 24360. Btuh Latent cooling 10440. Btuh Total cooling 34800 Btuh Aotual.airflow 1160 cfm, Airflow factor 0.046 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.83 to meet all of Manual J 8th Ed. wrigfitsoft' RlghtSukeO Unlwmal201717.0.14 RSU08101 ...nick CalcMD' emientilTHE GRAND CARLTON-1446.mp Cale = MJ6 Front Door faces: N 2017-Apr-11 09:29:38 Page 1 wrightsoft° RighW@ Worksheet Job: 9 Entire House Date: By. QUICK CAL.CS,INC. 117 ST. LUCIE LW, FT. PIERCE, FL 34946 Phone: 772-4660799 Fax 772-413"796 QUICKCALCftAOLCOM Flail: Room name I2 --- �--- -- � _ F1Bire House BEDROOM Bpcsee wall 3 red 8 7 ft 156 z n d o tt 5 Room am �lo� 1445.5 ff 8.0 It ,+-o z9ao n heat/000l : zs7.o to 7 Ty Construction U-wlue 'Or HTM Area (fl?) . Load AM (ft') Lead i number (BtutJH•) or perimeter (R) Pull) or perimeter- (fl) (6tuh) .. Heat I Cool Gross WP/S Heat Cool Gmss WP/S. Heat Cool i +9143 n 400 --'2156 2;55 503 '.',: 465 .:1f862 -.1144 IA5.2tfrlt .' ,0:7711 it 19:3'I' As :., 0 ..'815. -730 10 ' 0 i urcrom 1.27U a 35.55 87.29 24 2 848 2082 O 0 0 0 �1 .. 11D0 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W - - M4ocs 0.143'-se .4.00 .'255 -, .w 34 436 86. -0:.. ..0,:: l W 13A4ocs 0.143 s 400 255 360 353 1414 899 216 216 865 550 �--ra 1Actom 1.270 a 3556 34.77 7 7 2R7 241 0 O 0 0 y/ cs ; .0.193 w` . 4IW 255 310 ` .237 949 : 603 `104 72 288 186 �—G IS-H 11Aolorn ..1.270 w' .. 3556 55.21 32 '. 2 1140- '1770 .32 2,- 1140 1770 r— C'�'4AS,7om :0;770 w 21.56 19;31 41 , 4,1 . , 880 ''.788 -0- 0 0 , a P -x 12C41sw 0.091 255 1:28 192 192 489 246 0 0 0 0 Ci Pi6A 39md ,.O�o3z ;-=090 232 1446 ::'- 1446 %._;1295 , '.3354 29711:: z9Z :i 2s6 -:689( F 22A-tpl 0.989 2769 000 1446 156 4325 0 297 49 _1357 0 -,:. .. :•' _ - I i li f c)AED euursion - 918 627 Envelops loss/gain 14961 13349 4204 4003 112 a): Infiltration . 2887 '791 848 232 j t b) Room ventilallm 0 0 ., 0 0 1 i Wemal galns: Occupants Q 23D 6 1380 3 690 �j Appliances/other 2000 0 I� Subtotal ulnas 6 to 13) 17848 17520 'S053 4925 . Less eldemal load - 0 0 0 0 Less transfer 0 0 0 0 Redistribution b fatal (� 0 0 0 0 1 . 17848- 17520 5053 4925 15, Duct loads 3231 49% 5654 8536 32% 49% 1601 2400 Total loom load 23503 - 26056 6653 7325 Air required (cfm)'- 1160 1160 .328 Calculations approved byAotxt6ii wfiii r 6imments of Manual J 8th Ed.. �+ weighLsofY 2017-Apr-1109:29:38Page RlghtSuhe® Universal 201717.0.14 RSU08101: 1 .:.uick CsIcs1DOcumentsV)E GRAND CARLTON-1446.mp Calc=MJB Front Doorfaces: N i' J'wr'igtitseft° RighWOWorksheet Job: Entire House. Date: QUICK CALCS, INC. By., ,317 frr LUCIE LN., FT. PIERbE, FL 34946 Phone: 772-466E799 Fax 772-466-6798 Em l: QUICKCALCS ,AOLCOM " Ni-Roam �12 name _ _ _ WIC KRCHFN E1posed wall 0 ft O ft 3 Room height 8.0 ft heaticool &0 It heWCool 4 Room dimensions Room area 6.0 x 9.0 ft 1.0 x 1720 ft 16 54.0 ft 1720 ft' ITy Construction U-value Or HTM Area (ft9 Load .Area ft Load 11 number (BhHftz°F) (Btuhlft2) or Perimeter (ft) (Btuh) or perimeter.- (ft) (Bluh) Heat I Cool Gnus WFlS Heat Coal Gross NMS Heat Cool "i 6 n. 13A+locs lip, 0 0 .':p 0;/ • -4AS2arr 13A-0acs 770 0.143 n a -2156 4.00 ,Jg11 255 0 " 0 0 10 -" - - b 0 ' _ 1Ac1om 1.270 a 35.66 87.29 . 0 0 0 .0 0 0 0 0 0 0 0 0 0 11 _ I—f) 11D0 0.390 a 10.92 11.31 0 0 0 0 0 0 0 W., i13A�aCs'. _ - - . 0:143 se =4:00 255 -. 0 ... p 0,. 0 '. 0 6 "..0' . L}/ L-G 13A-0aos 0.143 a 4.00 255 0 0 0 0 0 0 .: 0 1ACl m 1270 s X66 34.77 0 0 0 0 0 0 0 13A-0acs ,.. .0.143 si 4.00 2550 -.:. .0 0 .0 p' .0,. 0. 1.270 w'. ..3566 55:21 . 0 0 0. ". .: p ...0 0 0- -. 4A5-tom -.0.770 w 2158 law 0- 0 0 0 P. 12C Qsw 14A-30m&.;= .. 0.091 0.032 255 ;:0.90 1.28 ... 2;32, 0 54 0 t: *. :54'-: 0 ".. 48 0 :.: ..'12,1 64 64 ' 163 1 F 22A4p1 0,989 2769 0.00 54 0 . 11:172 172 0 0, Ali _:(:. •: :: :.. .. .:... ,.., -:.. .. " ., ,,. ...:, , �.'- .... ".; ., .,, ...... _? 6j c)AEbemwsion -g -170 AEnvelope losslgain 48 117 317 311 n. 12 a) kl8ihatlon 0 0 0 0 Room verROation 0 0. .0 0 li 11 Internal gains: Occupants @ 230 ' 0 0 - 0 0 ,i Appliancestother 0 2000 I Subtotal pines 6 to 13) 48 117 317 2311 Less alemal load 0 0 0 0 Less transfer 0 0 SuubbMaall 0 0 0 0 1 117 317 .1 Duct loads11 32% 49% 15 57 32% 49% 100 1125 Total room load 64 178 . Air required. (cfm) . 421 ..3 53 I - -qF wrrgnisoii- 2017-Api-1109:29:38 mRightSuite@ UnNema12Oi7l7.0.14 RSU08101 Page 2 ...ulek CalwkDccuems\THE GRAND CARLTON•1446.rup Cale = MJ8 Front Door faces: N +Wrightser RighWO Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LW, FT. PIERCE, FL 34946 Phone: 772-46BV49 Fas 77ZA66-6796 Email' OUICKCALCS@AOL.COM -BEDROOM-2 -- - 11 Room name BATH 2 .i1,3. .F�glosed v211 Room height 5.0 ft 8.0 It beaked 8.0 ft 34.2 ft heaVcool l4 E5 Room dimensions Room area 1 9.0 x 45.0 ft- 6.0 it 1.0 203.5 ft2 x 203.5 it Ty Construction number U-value (Btutyftz F•) Or HTM (Btuhlft� Area or perimeter (ft) Load Pull) k- (ft2) or perimeter. (ft) Load (Btuh) Heat Cool Gross NIPIS Heat Cool Gross NIPIS Heat Cool _ 16 �I f3(w46cs' :4A5-tom ". -. 13A-0acs �OS143 .0:770 0.143 n n a '4;W. .'".21.56 50 '255- 79,31: 2.55 q0 "0 0 :.: 40 '� .'0:.. - 0 :...A80 .`. 0 0, -102 ""0 0 128:; .�O.r- 80 128 - O' 56 �'; $13326 0 225 ="0 143 .I--G lIN-G 11 _D 1Aclorn 1100 1.270 0.390 a a 35.66 10.92 97.29 11.31 0 0 0 0 0 0 0 0 24 0 2 0 849 0 2082 D Vy ,M40cs --.... 0.143. - se -.4.0D : 255- 0 °0 .0 : 0 :. 34 .:: -.34 138 .. 8 4N 13A-4ocs 0.143 s 4.00 255 0 0 0 0 32 32 128 8 I--f' 1Ac1cm 1.270 s 35.56 34.77 0 0 0 0 0 0 0 13A41ocs - A.143 W. 400 2.55: 01,0 0 .0 0 0 tl A - Tom .1270 w .355E 552Y, .0: 0 - 1) .,.0 0 0 A 1 4AS2an OiTID ,w 2156 .19.31:: 0:.. 0 : 0 .0 :. 0 0 P. 12C-Dsw 0.091 255 1.28, 0 0 0 0 ,Q 0 0 0 .i -:.-;0:03232 -. c45.,:', 45 >:'> '. 40 _.'; :: 104. 204 F. 22A4p1 0.999 : - 27.69 0,00 45 5 138 0 204 34 946 i 12�-- a)Infiltration . 87 24 593 182 'b) Room venNation 0 0 0 0 13.' Internal gains: Occupants Q 230 0 0 - 1 . 230 Appriances/other .0 0 Subtotal pines 6 to 13) - 425 214 3571 349E .I'i Less e4emal load .. 0 0 .0 Less transfer 0. 0 0 - :0 - 0 0 0 : 0 1g'. Subtotal 425 214 3571 349E 15 Duct loads - 327. 4W. 135 104 32% 49% 1131 1704 Total loom' load 560 318 47M 5203 'Air requved(cfm) 281 14 1 1 232 232 Calculations approved bvACCA to meet all requirements of Manual J_8th Ed. . L=_ .-Ft- wrighLsofL' U 2017-Apr-1109:29:38Page A RightSuBe® Universa1.201717.0.14 RSU0810Y - - 3 II ...uick CalcslDocumentslTHE GRAND CARLTON-1446.mp Cale = MJ8 Front Door faces: N • IF wrightsofr Right=J® V(lorksheet Job: Entire House Date: By: QUICK mcs, INC. 31�7ST. CUCIE LN FT. PIERCE, FL 34946 Phone: 772-466-6799 Fas 772-46"796 Emil; QUICKCALCS(a)fOLCOM 1 Room name LAUNDRY GREAT/DINING 12 FVosed wall 6.0 ft 47.0ft �3 Room height 8.0 It heat/cool 9.8 ft heaticool Room dimensions 7.0 x 6.0 ft 1.0 x 526.0 ft 14 5 Room area 42.0 ft' 526.0 W Ty : Construction U-value Or H'fM Area Area number (BtuMftMF) (Btuwfti or perimeter (0) (& ) or perimeter (ft) (Btuh) Heat Cool Gross WPIS Heat Cool Grass NIPIS Heat Cool 'i3h4Qcs -:-0143 P ^ od 255 0_;.._ 0 0 :D 255;; 217 .`-r '869 ?552 ?lam;CgA5•ZOm. :'. ",D770 n ... ":2156- =10j31. 0'.: 0- .e 0 ?O ,38 't 0 � 13A-4= 0143 a 4.00 255 0 0 0 0 0 .0 0 0 IAclom 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 t--0'11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 -W 1', A349ocs _ 0.143 se -.4:00 255 0 0 0. 0 '. 0 .0=' l71 13A-4oes 0.143 s 4.CO 265 48 48 192 122 0 0 0 0 �--fi 1Ac1om 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 13AAOM .0143 w 400 2.55 0 0 0 0 206' 165 661 421 :7Ac1pn -: 1-.270 w WAS 5521 .o 0 o. .0 0' o.' 0 9A52em , , 0:770 w , r2155 ' . 19:31 0 ... 0 0 0 4t. P 12C-0sw 0.091 255 1.28 56 56 143 72 0 - 0 0 1 C �;],6A30md ... '0.-032 "i090 e232 42 -.r' 42 38 -. -'. 97 628?,i - ' F 22A-tpl 0.989 2769 0.00 42 6 166 0 526 47 1302 I : I b) Room ventOafian 01 0I 10 0 13 Intemal gams: Occupants Q 230 0 0 2 ,460 AppOanceslother 0 0 Subtotal (lines B to 13) 643 298 6994 , 5112 Less edemal load 0 0 - 0 0 i Less transfer 0 0 . 0: 0 I Redistribution 0 0 0 0 A 414- wright aftr RlghtSuite@ Unlversel 201717.0.14 RSU08101 ...uick CalcslDocuments\THE GRAND CARLTON-1446.mp Cale = MJB Front Door faces: N i 2017-Apr-11 09.29:38 Page 4 wrightsort Rightm-M Worksheet Job: Entire House Date: QUICK CALLS, INC. By: 3f7 ST. LUCIE LPL, FT. PIERCE, FL 34946 Phone: 772-086.6799 Fac 772-466-6796 Ema1: OUICKCALCS@AOLCOM i1 Room name - ed Wall FOYER fi7. BATH. i 3 Rmm height 8.0 ft 7.0 ft heaticool 8.0 ft 8.0 ft heatlwd :4 " ! Room area dimensions 5 Room area 1.0 x 50.0 ft 7.0 x 8.0 ft 500 ft 56.0 ft o Ty. non5stmc8on U-Value Or HTM Area - Load Load (Btuh/WF) (BW RI) or perimeter (ft) (etuh) a perimeter (ft) (Btuh) Heat Cool Gross NOS Heat Cool Gross NO& Heat. Ced 6 a„13A4gcs ''4AS2om ` '0143 n ',40-1 - 8-. 8 32 ..20 0!:. 0 .. 13A-0ocs 1A-clom - ;0770 0.143 n a ..-2T.5p 4.00 ••19.31 255 48 0 ;' 27 0 108 0 -0 69 0:' 0 0- 0 0 1.270 a 3656 87.29 0 0 0 0 0 0 0 0 11 � 1100 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 ' rW':'..°' 13A-0ocs-. 0:143 ' se . 4.00 '255 0 .0 0 . 0 - 0 , 0 47/ I-C 13A-0orn 1Actan 0.143 s 4.00 255 0 0 0 0 64 145 .13A4ocs - 1Ac1om 1.270 0.143 T270 s w w 3568 400 35M 34.77 255 55.21 - 0 0 0 0 0 0 0 0 .0 7 0 0 7 247 e 241 '•'0 '. 0 0 .0 p ; p P 4(vra2an 12GAsw .(D.770 0.091 w ;;.:'2156 19•'k1 "e7 .. Or 0•', ,0 .0 . . i :18A=30md''',:. : 0:'032 2.55 .:,;090 1:28 . _. :.. 232 " 72 >so 72 - `) : Sc 133 - _ :_' 45 92 'i ` �. '116 0 , ?55 0 is 66 0 .... '; 50 0 --1b 130 F .22A-tPI ,.. 0.989 - 2789 0.00 50 7 194 0 56, • 8 222. .._0lr l c)AEO elxursion -39 l i Fmelope lass/gain _ 792 496 747 478 12 a) Olfilt a8on 121 33 138 38 i' b) Room ventilation 0 0 " 0 0 13' Intemal gains: Occupants @ 2M 0 0 0 - 0 'i Appliancestother 0 ;.i Subtolal Oines 6 to 13) - 913 629 885 Less e>demal load 0 0 0 1,616, li 'Less transfer 0 00 ' Redistribution 0 0 0 14 .Subtotal 913 529 88515 DUct loads 32% 49% 299 2.6 A2oa dW/ 9nn p' Wright50Po' RlghtSuBe®Univemal207717.0.14RSU08101 ...uiek CaleslDOeamentsITHE GRAND CARLTON-1446.mp Cale = MJ8 Front Door faces: N 2017-Apr-11 09:29.38 Page 5 Duct System Summary Job: wrightS�fit° Y Date: Entire House By: QUICK CALCS, INC. 817 ST. LUGE-Lf1_.FT. PIERCE, FL 34946 Phone:.772466-679's Fax 772-466-6796 Email: QUICKCALCS AOL.COM - For. THE GRAND WYNNE DEb kemal static pressure ressure losses mailable: static pressure' jupply /'return available pressure 5west friction rate ctual- air flow . tal effective length (TEL) AKLI UN .OPNIENT, FT. PIERCE, FL Heating. 0.50 in H2O. 0 ,-in'H26 .0.60 .in H2O 0.250 / 0.250 in H2O 0.285 in1100ft 1160 cfm Cooling' 0.50 in H2O 0 in H2O 0:50 in H2O 0.250 / 0.200 in H2O 0.285 in/100ft 1160 cfm 176 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (n) H x W (n) Duct Mail 'Actual Ln (ft) Ftg.Egv Ln (ft) Trunk i, BATH h 560 28 14 0.364 4.0 OxO VIFx 22.4. 115.0 SH BEDROOM 2 h 4702 232 232 0.360 7.0 Ox0 VIFx 23.9 115.0: SO BEDROOM -A h 3327 164- 163 0.300- 6.0 Ox0 VIFx .31.8 135.0, st2 BEDROOMA h 3327 164 163 0.285 6.0 OxO VIFx-- 40.6 135.0 st2 FOYER h 1202 59 35 0.505 4.0 0x0 VIFx 4.0 95.0 GREAT/DINING h 3946 195 169 0.300 7.0 0x0 VIFx 31.8. 135.0 st2 GREAT/WRIM-A h 3946 195 169 0.300 7.0 Ox0 VIFx 31.8 135.0 st2 KITCHEN C 3437 21 153 0.379 6.0 OxO VIFx 17.0 116.0 st1 LAUNDRY h 846 42 20 0.361' 4.0 Ox0 VIFx 23.3 '115.0 st1 M. BATH -A h 768 58 34 0 0 OX0 VIFx 0 0 vvtc c 174 3 6 0.309 4.0 OXO VIFX 27.0. 135.0 Sl2 Trunk Htg Clg . Design Veloc Diam H x W Duct ;Name Type (cfm) (cfm) FR (fpm) (n) (n) Material Trunk st2 Peak AVF 721 672° `0.285 918 12.0 0 x 0 VinlFlx st1 S. Peak AVF 1043 1091 0285:- 1020 14.0 0 x 0 VinIFIX wrightsoft Right -Suite® Universal 201717.0.14 RSU08101 . ...Lick Calos\DocumentskTHE GRAND CARLTOM1446.rup Calc = MJ8 Front Door faces: N 2017-Apt-11 09:29:38 Page 1 Grille Htg Cig TEL Design Veloc Diam. H x W Stud/Joist .Duct Name- .Size(in)' (cfm) (cfm) (ft) FR (fpm)- (in): (in) Opening(in). Matt. Trunk ib1 Ox0 1160 1160 0 0 0 0 Ox 0 VIFx h yJ{} wri htsoft' 2017-Apr-'n 0s:z0:9e 9 RightSuite®lNiversa1201717.0.14 RSU08101 � page2 ^*!"^....ulck CalcsMocumentsITHE GRAND CARLTON-1446.rup Cale = MJ8 Front Door faces: N