Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FILE COPY FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: �NNE THE STERLING BuiPerlder Name: DEVELOPMENTNE SCANNED Street: STERLING nnt Office: ST NUC E OUNTY City, State, Zip: PIERCE, FL, Permit Number. St 2FT. Owner: J �y �) Jurisdiction: Luc) a COUntr Design Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types(1442.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft' b. Frame - Wood, Adjacent R=11.0 192.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft, 4. Number of Bedrooms 2 d. N/A R= ft' 5. Is this a worst case? Yes 10. Ceiling Types (1474.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1474.00 ft' 6. Conditioned floor area above grade (ft2) 1474 b. WA R= ft' Conditioned floor area below grade (ft') 0 c. N/A R= ft' 11. Ducts R ft' 7. Windows(141.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 300 a. U-Factor: SgI, U=0.63 101.25 ft' SHGC: SHGC=0.25 b. U-Factor. SgI, U=0.65 40.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 34.8 SEER:15.00 c. U-Factor. WA ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor. WA ft' a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.239 14. Hot water systems 8. Floor Types (1473.5 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft' b. Conservation features EF: 0.970 b. N/A R= ft' None c. N/A R= ft' 15. Credits Pstat Glass/Floor Area: 0.098 Total Proposed Modified Loads: 48.34 PASS Total Baseline Loads: 48.53 1 hereby certify that the plans and specifications covered by Review of the plans and STg n this calculation are in compliance with the Florida Energy specifications covered by this Oti4JJE Code. calculation indicates compliance with the Florida Energy Code. PREPA D Y' Before construction is completed r C DATE: l this building will be inspected for compliance with Section 553.908 O r a I hereby certify that this building, as designed, is in compliance Florida Statutes. lt, '0 with the Florida Energy Code. WE OWNER/ARK T: BUILDING OFFICIAL: DATE: A DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 4/17/2018 2:37 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 PROJECT Title: WYNNE THE STERLING Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned -Area: 1474 Lot# _ _ _ Owner Name: — Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180 Street: THE STERLING Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL. New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1474 11792 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 329 2632 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 329 ft' -- 0 1 0 2SIab-On-Grade Edge Insulatio WIC 1 ft 0 63 ft' --__ 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft' 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 192 ft' 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft' -_ 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft' ___ 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft' -_ 0 1 0 4/17/2018 2:37 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FbRM R405-2017 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY Bit _ _ _ 0-- 42-ft' _- 0 -1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft' 0 1 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck PitchV # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) - 1 Gable or Shed Metal 1553 ft' 246 ft' Light 0.6 No 0.9 No 0 18.4 ATTIC J# Type Ventilation Vent Ratio (1 in) Area FIBS IRCC 1 Full attic Vented 150 1474 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 329 ft' 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft' 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft' 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft' 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft' 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft' 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft' 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft' 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft' 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NE=>SW Exterior Concrete Block - Ext Ins®EDROOM 4.1 10 0 8 0 80.0 ft' 0 0 0.6 0 2 SW=>NE Exterior Concrete Block- Ext Ins®EDROOM 4.1 28 0 8 0 224.0 ft' 0 0 0.6 0 3 NW=>SE Exterior Concrete Block - Ext Ins®EDROOM 4.1 14 0 8 0 112.0 ft' 0 0 0.6 0 4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft' 0 0 0.6 0 5 NE=>SW Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.6 0 _ 6 NE=>SW Exterior Concrete Block - Ext InfilEDROOM 2 4.1 16 0 8 0 128.0 ft' 0 0 0.6 0 _ 7 SE=>NW Exterior Concrete Block - Ext IngffDROOM 2 4.1 10 0 8 0 80.0 ft' 0 0 0.6 0 _ 8 S=>N Exterior Concrete Block - Ext IngffDROOM 2 4.1 4 3 8 0 34.0 ft' 0 0 0.6 0 9 SW=>NE Exterior Concrete Block - Ext InREDROOM 2 4.1 2 0 8 0 16.0 ft' 0 0 0.6 0 10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft' 0 0 0.6 0 11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft' 0 0 0.6 0 _ 12 SW=>NE Exterior Concrete Block - Ext InsdlAUNDRY 4.1 6 0 8 0 48.0 ft' 0 0 0.6 0 13 NE=>SW Exterior Concrete Block - Ext Ins3REAT/DINT 4.1 26 0 8 0 208.0 ft' 0 0 0.6 0 _14 NW=>SE Exterior Concrete Block -Ext lns8REAT/DINT 4.1 20 0 8 0 160.0 ft' 0 0 0.6 0 16 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft' 0.23 0.6 0 4/17/2018 2:37 PM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FdRM R405-2017 DOORS # Omt Door Type Space Storms U-Value Width Ft In Height Ft In Area t SE=>NW —Insulated ENTRY None .39 3 1 6 8 20.6 ft' WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall V # Omt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW13 Metal 5 NW=>SE14 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes 0.63 0.25 N 32.9 ft' 1 ft 0 in 1 ft 4 in 0.63 0.25 N 6.9 ft' 1 ft 0 in 1 ft 4 in 0.63 0.25 N 24.0 ft' 6 ft 0 in 1 ft 4 in 0.63 0.25 N 37.5 ft' 1 ft 0 in 1 ft 4 in 0.65 0.21 N 40.0 ft' 8 ft 0 in 1 ft 4 in Drapes/blinds None None None Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft' 315 ft' 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000366 1375.7 75.53 142.04 .2598 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft' 4/17/2018 2:37 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 DUCTS / — Supply — — Return— Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat- Cool 1 Attic 6 300 ft2 Attic 75 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programabl[e Ceiling Fans: ]Thermosta�[t:)]Y Heating ( Jan Feb Mar E ] ] AApr [ May �X � Jun [X] [ ] Jul [ ] ri Aug [X] 1 Sep � j Oct L J Oct �rX Nov Dec Dec Venting [)Jan [ 1 Feb l l X Mar [Xl [[ 11 E 11 Jun I 1 Jul [ 1 Aug E 1 Sep lxl [X� [ ] Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4/17/2018 2:37 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE STERLING Builder Name: WYNNE DEVELOPMENT Street: THE STERLING Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION_ INSTALLATION CRITERIA General - Acontinuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceilinglattic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed, minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall, thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exteriorwalls, or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. - Caulking or other adhesive sealants shall not be used to fill voids a. In addition, inspection of log we shall be in accordance with the provisions of ICC-400. 4/17/2018 2:38 PM EnergyGauge® USA- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 `FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. THE STERLING, FT. PIERCE, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft' b. Frame - Wood, Adjacent R=11.0 192.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 2 d. N/A R= ft 5. Is this a worst case? Yes 10. Ceiling Types Insulation Area a. Under Attic (Vented) R=30.0 1474.00 ft' 6. Conditioned floor area (ft� 1474 b. WA R= ft' 7. Windows" Description Area c. N/A R= ft' a. U-Factor: Sgl, U=0.63 11. Duds 101.25 ft' a. Sup: Attic, Ret: Attic, AH: Attic R ft' 6 300 SHGC: SHGC=0.25 b. U-Factor. Sgl, U=0.65 40.00 ft' SHGC: SHGC=0.21 12. Cooling systems kBtu/hr Efficiency c. U-Factor. N/A ft' a. Central Unit 34.8 SEER:15.00 SHGC: d. r: N/A SHGC: SHGC: 13. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 3.832 ft. a. Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average SHGC: 0.239 S. Floor Types Insulation Area 14. Hot water systems a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft' a. Electric Cap: 40 gallons b. WA R= ft' EF: 0.97 c. N/A R= ft: b. Conservation features None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant feature \ Builder Signature: =s�^ Date: Address of New Home: �_� � L City/FL Zip- 3 *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/17/2018 2:37 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 -�- wrightsoftProject Summary Entire House QUICK,CALCS, INC. 317 ST. LUCIE LN, FT. PIERCE, FL 34946 Phone: 772-4666799 Facc 772-4666796 Emil: Ct For. WYNNE DEVELOPMENT THE CARLTON 299, FT. PIERCE, FL Notes:-� '`� all Weather. Fort Pierce, FL, US Winter Design Conditions Outside db 42 OF Inside db 70. OF Design TD 28 OF Heating Summary Structure 18188 Btuh Ducts 5654 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 23842 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 t' He1474 Co a14 Area (fl) Volumez 1.0�.455 10.223 Airchanges/hour Equiv. AVF (cfm) 92 47 Heating Equipment. Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A"030 AHRI ref 7914585 8.5 HSPF 34600 Btuh @ 47°F 27 OF 1160 cfm 0.049 cfm/Btuh 0.50 in H2O point = 33 OF Backup: Input = 7 kW, Output = 23009 Btuh, 100 AFUE Job: Date: By: Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range Relative Humidity L 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 17877 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swingg multipplier Equipmenfsensibleload 0.95 25093 Btuh Latent Cooling Equipment Load Sizing Structure 2958 Btuh Ducts 2319 Btuh Central vent (0 cfm) 0 Btuh (none) . Equipment latent load 5277 Btuh Equipment total load 30370 Btuh Req. total capacity at 0.70 SHR 3.0. ton Cooling Equipment Summary. Make Cartier Trade CARRIER AIR CONDITIONING Cond 25HBC536A'030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual airflow 1160 cfm Air flow factor 0.044 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.83 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft- RightSuite® Universal 2017 17.0.14 RSU08101 ... Wrightsoft WAMYNNE-THE GRAND CARLT014499.nry Ca1c=M.18 Front Door faces: N 2017-Apr-10 1 wrightsoft- RighW@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317.ST. LUCIE LN,FTPJERCEfFL34946 Phone: 72-46"799 Fax 772-46"795 Email: QUICKCALCS@AOLCOM 1 Room name Entire Horse BEDROOM 2 SpDsed wall 156.2 ft 52.0 ft 3 Room height 8.3 ft d 8.0 ft heat/000l 4 Room dimersiors 1.0 x 329.0 ft 5 Room area 1473.5 ft2 329.0 W TY Oonstn tion U-wlue Or HTM Area (W) Load Prey (ft.) Load number (BtUWftW) (BtuNft2) or perimeter (ft) (Btuh) or perimeter (ft) Pull) Heat Cool Gass WP/S Heat Cod Gross WPIS Heat Cool 6 I L--�': 13A4ocs - -.-,0.143 -.ne - 4.00 - 255 479 442 1768 ' 1124 80 - 80 320 ._ 204 tAclon _1270 .,no - 3556 '".70.43. -38 - -,0 .: 1344:' :2662' ..0 0 0 - - -0 % . 13AAocs 0.143 se 4.00 255 128 83 331 210 0 0 0 IL---GD 1Aclan 1.270 se 3556 34.77 24 48 848 829 0 0 0 0 11 11D0 0.390 se 10.92 11.31 22 22 236 244 0 0 0 0 W `--' 13A-4= 0.143 "•s, - - 4.00 255 r. 34 34 '136 . 86 0 , .0. --0 - - -b W 13AAccs 0.143 sw 4.00 255 360 353 1414 899 224 224 897 570 1--6 1Ac1om 1.270 sw 35.56 4291 7 11 247 298 0 0 0 0 13A4=-` -.0143 nW - 400 .`255 290' 217 867 :'"551 112 79 318 '202 5.tAclam�; .-4270 m =, 3556 .45.24 "- 33 0-- . 1162 1478 "33' O.L 1162 . 14 4AS2am •. _0770 rw.';'"21.56 ,27.54 141C 0 - 880 '. 124' '0 0::. 0. -...: P 12COsw 0.091 - 265 1.28 192 192 489 246 0 0 0 .. 0 C ".--..16A-Wrad - 0.032 . °- - .0.90 232 1474 1474 . 1320 . '-3419 329 329 - 295 F 22A4p1 0.989 27.69 0.00 1474 156 4325 0 329 52 1440 0 ( t. 6 c)AED excursion 784 680 Envelope loss/gain 15366 13954 4432 3897 12 a) trJiltratim 2822 773 909 249 b) Roomventilation 0 0 0 0 13 Internal gains: Occupants @ 230 5 1150 2 460 Appliances/other 20DD 0 Subtotal (lines 6 to 13) 18188 17877 5341 460q - Less e#enal load 0 0 0 0 Less transfer 0 0 0 0 Redishibution 0 0 D O 14 Subtotal 18188 17977 5341 4W6 15 Duct loads 31% 48% 5654 8536 31% 48% 1660 2190 Trial room land 23842 26413 7001 6805 ' Alr required(dm) 1160 1160 341 299 ,4g& f}i- wrightsoft- Right-Sufte® Universal 201717.0.14 RSU08101 ...Wdghlsoft WAC1WYNNE-THE GRAND CARLTON-299.mp Calc=MJ8 From Dcorfaces: 2017-Apr-10 wrightsoft• Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST.-LUCIE LN,-FT.-PIERCEFL 34946 Phone: 7724666799-Fax 772-4666796 Email: DUICKCALCS@AOL.COM 1 Room name WIC M. BATH 2 =ed wall 0 ft. 8.0 ft 3 Raom height 10 ft heatfood 8.0 ft heaHcod 4 Room dimensiors 7.0 x 9.0 ft 7.0 x 8.0 ft 5 Room area 63.0 ft' 56.0 ft2 Ty Constnlction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Bhltdfli'F) (BtuMft9 or perimeter (ft) (BIW) or perimeter (ft) (Btuh) Heat T Cool Gmss WP/S - Heat Cod Gross WP/S Heat Cod 6 Vy - ,-L--G` . 13AAc - -' - - - 0143 -ne 4,00 255 0 " 0. '0 •. ' 0 0 - 0 - 0 - .::.A0 .1Ac1onq ' :J 270 -ne' 35.50 ` .,70.43 :: ..' 0 ' =-0 - 0 ':0 . 0 -; '. "0 :0 ,.. .�=�0 11 13A.4ms 0.143 se 4.00 255 0 0 0 0 0 0 0 D �L(D- 1Ac1an 1.270 se 35.56 34.77 0 0 0 0 0 0 0 :D 11 11D0 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 WP ' J3A4ocs, awl - s 4.00 2.55 .0 °.0 0 . 0 0 = 0 ..0 W I-G 13AAcas 0.143 sw 4.00 2.55 0 0 0 0 64 57 .- 228 - '1d5 1Aoicm 1.270 sw 35.56 42.91 0 0 0 0 7 5 247 298 • 134-0 - 0143 nw 400 :255 0 �.0 0 -0 0 = 0 1270 nw 3556 :45.24 - .0 - 0 - 0 0 - = --0 ': 0 ...;0 4AS2ortr - ' •:0.770. rih 21.56 z27.54 _ -0 0.. _ 0 +' -.0 ,. 0 _-0 0 0 P 120-0sw 0.091 - 2.55 1.28 0 0 0 0 0 0 0 ;0 C:. : 16A30md 0.032 - 0.90 .2-32 63 63 . 56. 146 56 -56 F 22A4ol 0.989 - 27.69 0.00 63 0 0 0 56 8 222 b i l s c)AED=ursion -2 2A Envelope losslgain 56 145 747 74 12 a) Miiltmtion 0 0 140 38 b) Room Yentllation 0 0 0 0 13 htemal gains: Occupants Q 230 0 0 0 b Appliances/other 0 0 Subtotal Qires 6 to 13) 56 145 887 836 Less cAernal load 0 0 0 0 Less transfer 0 0 0 0 Redistn'hulion 0 0 0 0 14 Subtotal 56 145 897 836 15 Duct loads 31% 48% 18 69 31% 48% 276 _39r9 Total roan load 74 214 1162 1236 Air required (cfm) 4 9 57 54 A -FfF wrightisOfY RlghtSdte® UnWersal 201717.0.14 RSU08101 ...Wrightsoft WVAC1WYNNE-THE GRAND CARLTON-299.mp Cato=MJ8 Front Doorfaces: 2017-Apr-10 0 p A T � O f0 '$0000000000,00�A '. OM1 Oo0(ND V , m0 N' O Yn 4if Y1 N e OO 0 0 "E �0000000000;ova va P o '000 000000.o;o�ulo '- - 2 �. 00 0 N g. i3 000�� cis 19 0900000000'0.,��YO •" �' Y� 00 Y� OOOY�gN ,' O x O 00 00.00 ... P � W a p 0 �iRR`uR �'n �iR'33m v��N�i mN FoB ., = ri 8 `ug 8 `� �i88 �i 8 `IQi `�ii'u� 8i ffi . • /.�6 V O CCN NN mNE iE LL 0-0. O000�000.00�C�G OCO �m Jo 2 ��j �gQqjff p y �N E J.(yyyy3J dS�Ci�QN.. .. m�'.rm.O 5 C ¢�3,aCia,. ., ..I NdJY5�v7o .N- wrightsoft' RightJ@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT.-PIERCE1FL-34946'Phone: 772466-6799 Fax 772-466-6796 Email• OUICKCALCS@AOLCOM 1 Roxn name BEDROOM ENTRY 2 Exposed wall 322 ft 7.0 ft 3 Room height 8.0 It heal/cod 8.0 ft heallood 4 Room dimensions 1.0 x 203.5 ft- 1.0 x 55.0 ft 5 Room area 203.5 ft' 55.0 ft- Ty Construction U-1e1ue or -HTM Ama Load Area number I (BtulVft' F) (Btuwft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cod Gross WP/S Heat Cool 6 7344ocs- - --- -0143 ;be 4.00 255 '. 128. - 128 513 326 '- 0 _ 0 0 `. .0 L-� - .1Acldni 1.210 ne. `-'35.56 70.43 .. 0 -' 0. --0 - _ 0 . .. 0 .. 0.;" 0 ' 0 y/ 13A4ocs0143 as 4.00 255 80 56 225 143 48 26 106 67 L�-GO 1Aatom 1.270 as 35.56 34.77 24 24 848 829 0 0 0 0 11 11130 0.390 se 10.92 11.31 0 0 0 0 22 22 236 244 W ..,, .13A'Am, - 0.143 s • -"-4.00 :255 .. 34 34 136 . ..86 0 _. •'0 :0: ' '0 W t-C 13A4ocs 0.143 sw 4.00 255 16 16 64 41 8 8 32 20 1Ac1cm 1270 sw 35.56 4291 0 0 0 0 0 0 0 0 13A4ccs .0143 rnv '" 400 , -255 : 0 0 0 .0 " 0 '0.' 0 - 0 _ 1Actan '- 1270 mv. '_ ;35.56, 4524: - 0 0 0 0 0 0' 0 .•.'0 - 9A5-26m ,-0770 mv- 21:56 :' 27.54 0 , 0': 0 ' . -.0 0. ' 0 0 -..;0. P 128-0sw 0.091 - 255 1.28 0 0 0 0 72 72 183 92 C .teka0w 0.032 - - 0.90 232 204 204 182 472 55 65 49 F 22A-tpl 0.989 - 27.69 0.00 204 32 891 0 55 7 194 .128 0 6 c)AED excursion -24 -6 Envelope loss/gain 2859 1873 800 - 545 12 a) Nfittraton w 154 122 34 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants Q 230 1 230 0 0 Applianoes/other0 0 Subtotal (lines 6 to 13) 3422 2257 922 579 Less eodemal load 0 0 0 0 Less transfer 0 0 0 0 RedistddNon 0 0 0 0 14 Subtotal 3422 2257 922 579 15 Dud loads 31% 48% 1064 1078 31% 48% 287 276 Total roan load 1 4486 3335 1209 855 " Air required (cum) 218 146 59 38 P. wrighksof!- Right-SutteO Universal 201717.0.14 RSUD8101 ...Wdghtsoft WAC1WYNNE-THE GRAND CARLTON-299.rup CaIc=MJ8 From Doorlaces: 2017-Apr-10 wrightsoft• Right -A) Worksheet Job: Entire House Date: Liy: QUICK CALCS, INC. 317 ST. LUCIE-LN4 FT.-PIERCEFC34946-Phone: 772=466-6799 Fax: 772-466-6796 Email: DUICKCALCSa@AOL.00M 1 Room name LAUNDRY GREAT/DNNG 2 Eq:Osed wall 6.0 ft 48.0 ft 3 Room height &0 ft heagcod 8.9 ft - heaUcod 4 Room dimensions 7.0 x 6.0 ft 1.0 x 488.0 ft 5 Room ama 42.0 ft2 488.0 ft2 Ty Construction U-value Or HTM Amer (ft2) Load Neer (ft2) Load number (Budwit-F) (Bh,Wft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cod Gross WP/S Heat Cool Gass WP/S Heat Cod 6 W _ 934406s- - -0.143 '.ne. 4.00 = 255 -' 0' 0 0 ... 0 231 194 775 " - Ad, L--G 1Aa1om... .1.270 , ne 35.56 .70.43 0 - . -0-- - ..-. 0 ` .0 ' 38 .:. ' . � 0 '-` 1344 . ' ', 2667 13A4acs 0.143 se 400 Z55 0 0 0 0 0 0 0- 0 1Actont 1.270 se 35.56 34.77 0 0 0 0 0 0 0 0, 11 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0: W' .:° _ j93A-flocs. 0.743 * s .. 4.00 r -.255 0 0 •. 0, 0 - . -0 . 0 :0 ;10. W YC 13A4ocs 0.143 sw 4.00 2.65 48 48 192 122 0 " 0 0 0 1Aclom 1270 sw 3556 4291 0 0 0 0 0 0 0 0 -13A4acs .0143 my 40D . -Z55 0 0 0 - :0 .178 : 137 - 549,i349 _1270 my :.. .3556 45:24 -.0, 0`:- ' 0 ._ .0 0' 0- - 0 0� 0.770 nw . - 2156 -27.54 0 ' 0 `. - 0 :0 '41 ' .0 ' 880 • 1124! P 12C-0sw 0.091 - 255 1.28 56 56 143 72 0 ' 0 0 . 0 C .16MADmd '0.032 - .0.90 232 42 42 38 97 488 488 437 .: 1132. F 22Atpl 0.989 - 27.69 0.00 42 6 166 0 488 46 1274 0, I 6 c)AE excursion 3 -56 FJnelope loss/gain 539 288 5259 5704 12 a) 9dttration 105 29 895 245 b) Room ventilation 0 0 0 0 13 Internal gins: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal Dines 6 to 13) 644 317 6154 6409 Less eDdemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 644 317 6154 6409 1,91 Duct loads 31% 481/6 200 151 31% 48% 1913 3060 Total room load 644 468 BD67 9469 Air required (cfm) 41 21 393 416 A&A wrllgncso7r RlghtSuHsO Universal 201717.0.14 RSU08101 ...Wdghtsoft WAMYNNE-THE GRAND CARLTON-299.mp Calc = MJ8 Front Door faces: N 2017-Apr-10 Page wrightsoft Duct System Summary Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466.6796 Emit: OUICKCALCSOAOLCOM Job: Date: By: Project Information For. WYNNE DEVELOPMENT i THE CARLTON 299, FT. PIERCE, FL Heating Cooling Extemal static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply / return available pressure 0.250 10.250 in H2O 0250 / 0.250 in H2O Lowest friction rate 0.284 in/100ft 0.284 in/100ft Actual air flow 1160 cfm 1160 cfm Total effective length (TEL) 176 ft I SupplyDetail Table I Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (In) (In) Matt Ln (ft) Ln (ft) Trunk BATH h 559 27 15 0.376 4.0 OxO VIFx 18.1 115.0 st1 BEDROOM h 4486 218 146 0.374 6.0 OxO VIFx 18.6 115.0 sH BEDROOM -A h 3501 - 170 149 0.297 6.0 OxO VIFx 33.1 135.0 st2 I BEDROOM-B h 3501 170 149 0.284 6.0 OxO VIFx 41.1 135.0 st2 ENTRY h 1209 59 38 0.510 4.0 Ox0 VIFx 3.0 95.0 GREAVDIMNG c 4735 196 208 0.318 7.0 0x0 VIFx 22.4 135.0 st2 GREAT/DINING-B c "4735 196 208 0.307 7.0 OxO VIFx 28.1 135.0 st2 wTCHEN O 3695 21 162 0.375 7.0 0x0 VIFx 18.3 115.0 st1 LAUNDRY h 844 41 21 0.366 6.0 0x0 VIFx 21.6 115.0 all M. BATH h 1162 57 54 0.366 4.0 OxO VIFx 21.6 115.0 st1 Wlc c 214 4 9 0.310 4.0 0x0 VIFx 26.3 135.0 st2 i Trunk Htg. Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (In) (n) Material Trunk I. st2 Peak AVF 737 724 0.284 689 14.0 0 x 0 VinlFlx st1 st1 Peak AVF 1101 1122 0.284 804 16.0 0 x 0 VinlFlx �• 'f ' wrightsofY Right.SuiteQ Uni Mal 2017 17.0.14 RSU08101 2017-Apr-10 17; 14:1 Page A.� ...WrighlsoR HVAC\WYMJE-THE GRAND CARLTON-299.rup Cale =MJB Front Door faces: N Grille Htg Clg TEL Design Veloc Diam H x W StucVJoist Duct Name -Size (in) _. _(cfm) - (cfm) {ft} FIR (fpm) (in) (n) Opening (n) Matl Trunk rb1 OxO 1 1160 1160 0 0 0 -OF Ox OF VIFx A+ wrightsoft• RightSuite® Universal 201717.0.14 RSUG8101 e017-Apr-10 ...WrightsoR WACIWVNNE-THE GRAND CARLTON-299.mp Cale = MJ8 ' Front Door faces: N