HomeMy WebLinkAboutREVISION - BUILDING PERMIT-File cop),
OFFICE USE ONLY:
DATE FILED: PERMIT# 19,0 /—(1
REVISION FEE: RECEIPT #
PLANNING & DEVELOPMENT SERVICES RECEIVED
BUILDING & CODE REGULATION DIVISION
M00 VIRGINIA AVENUE
FORT PIERCE, FL 34§82.5652' JUL 29 2019
(772) 462-1553
Lucie County,-P6m
APPLICATION. FOR BUILDING PERMIT REVISIONS
PROJE&INFO'RMAT16N
8CA
LOCATION/SITE BN"E"
y
ADDRESS: St. LUCie C
Ounty
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #:
BUSINESS NAME:
QUALIFIERS NAME:
ADDRESS:
CITY: STATE:
PHONE (DAYTIME):
OWNER/BUILDER INFORMATION:
NAME:
ST. LUCIE CO CERT. #:
Mw
CITY: 4sl— STATE:
PHONE (DAYTIME: 7— ei I - 9- C/ C/ 72 FAX:
ARCHITECT/ENGINEER INFORMATION:
NAME:
ADDRESS:
CITY:
PHONE (DAYTIME):
SWCC 9123109
Revised06130117
STATE:
FAX:
KAl2
ZIP:
190/-- 06'Fy
FORM R405-2017 ��ii �1�Coppy
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDINGe CONSTRUCTION
Florida -Department -of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE STERLING 3
Builder Name: WYNNE DEVELOPMEN
Street: 3 MAYA
Permit Office: ST. LUCIE COUNTY
JUL 2 9 2019
City, State, Zip: FT. PIERCE, FL,
Permit Number: 1901-0594
Owner:
Jurisdiction:
ST• Lucie County, Permitting
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climat
1. New construction or existing New (From Plans)
9. Wall Types(1442:0 sgft.)
Insulation___Atea.
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1250.00 ft'
b. Frame - Wood, Adjacent
R=11.0 192.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (1474.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1474.00 ft
6. Conditioned floor area above grade (ft2) 1474
b. WA
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Duds
R ft2
7. Windows(141.3 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 250
a. U-Factor: SgI, U=1.04 101.25 ft2
SHGC: SHGC=0.29
b. U-Factor: SgI, U=1.11 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.27
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.832 ft.
Area Weighted Average SHGC: 0.284
14. Hot water systems
8. Floor Types (1473.5 sgft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft2
b. Conservation features
EF: 0.970
b. WA R= ft2
None
c. N/A R= ft2
15. Credits
Patel
Glass/Floor Area: 0.096 Total Proposed Modified Loads: 44.72
PASS
Total Baseline
Loads: 48.47
1 hereby certify that the plans and specifications covered by
Review of the plans and
Sr97,
this calculation are in compliance with the Florida Energy
specifications covered by this
o4TE%E
Code.
calculation indicates compliance
y rbb ` s'Q
`.°
with the Florida Energy Code.
nnr"• •:°:_' , O
PREPABJED.Pyj
DATE:
Before construction is completed
this building will be inspected forlp
compliance with Section 553.908
O y
°
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
!t„
with the Florida Energy Code.
G'Op WE
OWNER/AGENT:
BUILDING OFFICIAL:
DATE: -7-ZG _ /
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4_1.2)_ &J, r r*
1.
7/29/2019 8:32 AM EnergyGauge® USA 6.0.02 (Rev. 1) -
Page 1 of 5
74
FORM R405-2017 LIT SUMMARY CMECKLI51 REF":. 'fT
PROJECT
Title: WYNNE THE STERLING 3 Bedrooms: 2
Address Type:
Street Address
-Building Type: —User— - Conditioned Area: 1474-
Lot #
Owner Name: Total Stories: 1
Block/Subdivision:
# of Units: 1 Worst Case: No
PlatBook:
Builder Name: WYNNE DEVELOPMENT Rotate Angle: 0
Street:
3 MAYA
Permit Office: ST. LUCIE COUNTY Cross Ventilation: No
County:
St. Lucie
Jurisdiction: Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
_ / Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75 299
62
Low
BLOCKS
Number Name Area Volume
1 Entire House 1474 11792
SPACES
Number Name Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1 BEDROOM 329 2632 No 0
1
1 Yes
Yes
Yes
2 WIC 63 504 No 0
1 No
Yes
Yes
3 M.BATH 56 448 No 0
1 Yes
Yes
Yes
4 KITCHEN 192 1536 Yes 0
1 No
Yes
Yes
5 BATH 45 360 No 0
1 Yes
Yes
Yes
6 BEDROOM 2 204 1632 No 0
1
1 Yes
Yes
Yes
7 ENTRY 55 440 No 0
1 Yes
Yes
Yes
8 LAUNDRY 42 336 No 0
1 Yes
Yes
Yes
9 GREAT/DINING 488 3904 No 0
1 Yes
Yes
Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0
329 ft'
___
0 1
0
2 Slab -On -Grade Edge Insulatio WIC 1 ft 0
63 ft'
__
0 1
0
3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0
56 ft'
—
0 1
0
4SIab-On-Grade Edge Insulatio KITCHEN 1 ft 0
192 ft'
0 1
0
5 Slab -On -Grade Edge Insulatio BATH 5 ft 0
45 ft'
—
0 1
0
6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0
203.5 ft'
__
0 1
0
7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0
55 ft'
0 1
0
7/29/2019 8:32 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 ,-'UT SUMMARY CHECKLIST REF` -, T
FLOORS
#
Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft
0
_
42 ft'
0_
_ _ 1
0
9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft
0
488 ft'
____
0
1
0
ROOF
_ /
Roof
Gable
Roof
Red
Solar
SA Emitt
Emitt Deck
Pitch
V
#
Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1
Gable or Shed Metal 1553 ft'
246 ft'
-Light
N
0.6
No 0.9
No -0
18.4
ATTIC
/
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented
150
1474 ft'
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented) BEDROOM
30
Blown
329 ft'
0.1
Wood
2
Under Attic (Vented) WIC
30
Blown
63ft'
0.1
Wood
3
Under Attic (Vented) M. BATH
30
Blown
56 ft'
0.1
Wood
4
Under Attic (Vented) KITCHEN
30
Blown
192 ft'
0.1
Wood
5
Under Attic (Vented) BATH
30
Blown
45 ft'
0.1
Wood
6
Under Attic (Vented) BEDROOM 2
30
Blown
204 ft'
0.1
Wood
7
Under Attic (Vented) ENTRY
30
Blown
55 ft'
0.1
Wood
8
Under Attic (Vented) LAUNDRY
30
Blown
42 ft'
0.1
Wood
9
Under Attic (Vented) GREAT/DINING
30
Blown
488 ft'
0.1
Wood
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing Solar
Belo w
1
N
Exterior Concrete Block - Ext Ins®EDROOM
4.1 10
0 8
0
80.0 ft'
0
0
0.4
0
2
N
Exterior Concrete Block - Ext Ins®EDROOM
4.1 28
0 8
0
224.0 ft'
0
0
0.4
0
3
N
Exterior Concrete Block - Ext Insi3EDROOM
4.1 14
0 8
0
112.0 ft'
0
0
0.4
0
4
N
Exterior Concrete Block - Ext InsuM. BATH
4.1 8
0 8
0
64.0 ft'
0
0
0.4
0
5
N
Exterior Concrete Block - Ext Insul BATH
4.1 5
0 8
0
40.0 ft'
0
0
0.4
0
6
N
Exterior Concrete Block - Ext InfilEDROOM 2
4.1 16
0 8
0
128.0 ft'
0
0
0.4
0
7
N
Exterior Concrete Block - Ext IndIEDROOM 2
4.1 10
0 8
0
80.0 ft'
0
0
0.4
0
8
N
Exterior Concrete Block - Ext InfiffDROOM 2
4.1 4
3 8
0
34.0 ft'
0
0
0.4
0
9
N
Exterior Concrete Block - Ext InSEDROOM 2
4.1 2
0 8
0
16.0 ft'
0
0
0.4
0
10
E
Exterior Concrete Block - Ext Insul ENTRY
4.1 6
0 8
0
48.0 ft'
0
0
0.4
0
11
E
Exterior Concrete Block - Ext Insul ENTRY
4.1 1
0 8
0
8.0 ft'
0
0
0.4
0
12
N
Exterior Concrete Block - Ext Insd1AUNDRY
4.1 6
0 8
0
48.0 ft'
0
0
0.4
0
13
S
Exterior Concrete Block -Ext lnsGREAT/DINI
4.1 26
0 8
0
208.0 ft'
0
0
0.4
0
14
W
Exterior Concrete Block - Ext In50REAT/DINI
4.1 20
0 8
0
160.0 ft'
0
0
0.4
0
15
E
Garage Frame - Wood KITCHEN
11 24
8
192.0 ft'
0.23
0.4
0
7/29/2019 8:32 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 UT SUMMARY CHECKLIST REV-j
DOORS
#
Ornt
Door Type
Space
Storms U-Value Width
Ft In
Height
Ft In
Area
- - 1
-SE- --
-insulated
ENTRY-
None .39- 3 1
6 --8 —20.6W
WINDOWS
Orientation shown is the entered, Proposed orientation.
#
Wall
Ornt ID Frame
Panes
NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation
Int Shade
Screening
1
2
3
4
5
N 3 Metal
N 4 Metal
N 7 Metal
S 13 Metal
W 14 Metal
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Yes
Yes
Yes
Yes
Yes
1.04 0.29 N 32.9 ft- 1 It 0 in 1 ft 4 in
1.04 0.29 N 6.9 ft- 1 It 0 in 1 ft 4 in
1.04 0.29 N 24.0 ft' 6 It 0 in 1 It 4 in
1.04 0.29 N 37.5 ft' 1 ft 0 in 1 It 4 in
1.11 0.27 N 40.0 ft' 8 ft 0 in 1 ft 4 in
Drapes/blinds
None
None
None
Drapes/blinds
Exterior 5
None
None
None
Exterior 5
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
315 ft'
315 ft'
24ft 8ft
11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356
1375.7 75.53 142.04 .1233
7
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity
Block
Ducts
1
Electric Heat Pump/
Split
HSPF:8.5 34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow
SHR Block
Ducts
1
Central Unit/
Split
SEER: 15 34.8 kBtu/hr cfm
0.85 1
sys#1
HOT WATER SYSTEM
#
System Type
SubTpe
Location
EF Cap Use SetPnt
Conservation
1
Electric
None
Garage
0.97 40 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cart # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft'
7/29/2019 8:32 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 6,,-UT SUMMARY CHECKLIST REF �-..T
DUCTS
/ — Supply —
—
Return—
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area
Leakage
Type
Handler
TOT
OUT ON
RLF
Heat Cool
1 Attic
6 250 ft-
Attic
45 ft'
Default Leakage
Attic
(Default)
(Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Cr(eiling Fans:
Veat ng Jan Feb
IFebrk,
Mar
�X]
]]
�x� Jun
[X�
[ ] Jul
X�
4 ] Aug
[ ]
[X] Sep
[ ] [[X]]
L�
Nov
Dec
L l
[X]
Apr
[
May
Jun
[) Jul
[)Aug
[)Sep
lxl Occtt [X]
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
-
Schedule Type
1
2
3
4
5
6
7
8
9 10
11
12
Cooling (WD) AM
78
78
78
78
78
78
78
78
80 80
80
80
PM
80
80
78
78
78
78
78
78
78 78
78
78
Cooling (WEH) AM
78
78
78
78
78
78
78
78
78 78
78
78
PM
78
78
78
78
78
78
78
78
78 78
78
78
Heating(WD) AM
66
66
66
56
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
Heating (WEH) AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 lbs/sq.ft.
0 ft'
Oft
0.3
BEDROOM
Default(8 lbs/sq.ft.
ft'
It
0.3
WIC
Default(8 lbs/sq.ft.
ft'
ft
0.3
M. BATH
Default(8 lbs/sq.ft.
ft'
ft
0.3
KITCHEN
Default(8 lbs/sq.ft.
ft'
ft
0.3
BATH
Default(8 lbs/sq.ft.
ft'
ft
0.3
BEDROOM 2
Default(8 lbs/sq.ft.
ft'
ft
0.3
ENTRY
Default(8 lbs/sq.ft.
ft'
ft
0.3
LAUNDRY
Default(8 lbs/s.ft.
ft'
ft
0.3
GREAT/DINING
7/29/2019 8:32 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 5 of 5
2017 - AIR BARRIER AND I::-;JLATION INSPECTION COMPONEI. r :RITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE STERLING 3 Builder Name: WYNNE DEVELOPMENT
Street: 3 MAYA Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number: 1901-0594
Y
U
Owner: Jurisdiction:
w
Design Location: FL, Fort Pierce
c=i
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks orjoints in the air barrier shall be sealed.
Ceilinglattic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in an dropped ceiling/soffit
y 9 /soffit
the insulation and any gaps in the air barrier shall be sealed.
air
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed,
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind nonino and wirino
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire snrinkler cover Mates and Walls or ceiling%
a. in addition, inspection or log walls shall be in accordance with the provisions of ICC-400.
7/29/2019 8:32 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARE^
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 92
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Duds, location & insulation. level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
2
13. Cooling system: Capacity
34.8
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1474
d) Room uniUPTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
1.060
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.284
14. Heating system: Capacity
34.8
c) Area
7c.
141.3
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
Sa.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
0 Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.97
b) Gas Fred, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
0 Heat recovery unit HeatReC%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1.
11.0
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
30.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
0 Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date: 7 • 2 6 'lq
Address of New Home: 3 MAYA City/FL Zip: FT. PIERCE. FL
7/29/2019 8:32:42 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1