ENERGY EFFICIENCY CODE
FORM R405-2017 FILE COPY TLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE ROYALE IMPACT Builder Name: WYNNE Street: WYNNE DEV. Permit Office: ST. LUCIE COUNTY q a1 Sy NIft City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: `3Gi (0cl( 'iC s\C,24\k q Jurisdiction: St. L Design Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2 �Cje County 1. New construction or existing New (From Plans) 9. Wall Types (1688.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1448.70 ft' b. Frame - Wood, Adjacent R=11.0 240.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 3 d. N/A R= ft' 5. Is this a worst case? Yes 10. Ceiling Types (1720.0 sgft.) Insulation Area . a. Under Attic (Vented) R=30.0 1720.00 ftz 6. Conditioned floor area above grade (112) 1720 b. N/A R= ft' Conditioned floor area below grade (ft2) 0 c. N/A R= ft' 11. Ducts R ft' 7. Windows(155.4 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 260 a. U-Factor: Sgl, U=0.63 115.42 ft' SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.316 ft. Area Weighted Average SHGC: 0.240 14. Hot water systems 8. Floor Types (1720.0 sgft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1720.00 ft' b. Conservation features EF: 0.970 b. N/A R= ft' None c. N/A R= ft' 15. Credits Pstat Glass/Floor Area: 0.090 Total Proposed Modified Loads: 55.37 PASS Total Baseline Loads: 56.24 1 hereby certify that the plans and specifications covered by Review of the plans and S7g1F this calculation are in compliance with the Florida Energy specifications covered by this 04gji6 Code. calculation indicates compliance ° e with the Florida Energy Code. Fr nxr> °;. PREPA D Y: Before construction is completed V O DATE: this building will be inspected for compliance with Section 553.908 c7 Q1f - A I hereby certify that this building, as designed, is in compliance Florida Statutes. !� with the Florida Energy Code. G'0 WE OWNER/AGEAIT BUILDING OFFICIAL: DATE: 1\• .L DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 4/17/2018 8:47 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 PROJECT Title: WYNNE THE ROYALE IMPA Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1720 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE Rotate Angle: 135 Street: WYNNE DEV. Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE _ / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1720 13760 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 343 2744 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M. BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 172 1376 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 98 784 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 528 4224 No 0 1 Yes Yes Yes 10 BEDROOM 3 169 1352 No 1 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 343 ft' __-_ 0 1 0 2SIab-On-Grade Edge Insulatio WIC fit 0 63 It' ___ 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft' — 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 172 ft' — 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft' 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 42.6 It 0 204 ft' _- 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 6.3 It 0 98 ft' 0 1 0 4/17/2018 8:47 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 FLOORS # Floor Type Space Perimeter-PerimeterR-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 - 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 48 ft 0 528 ft2 0 1 0 10SIab-On-Grade Edge Insulatio BEDROOM 3 13 ft 0 169 ft2 _ 0 1 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1813 ft2 286 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1720 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 343 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 172 ft2 0.1 Wood _ 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 98 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 528 ft2 0.1 Wood 10 Under Attic (Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 N=>SE Exterior Concrete Block - Ext Ins(BEDROOM 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0 2 S=>NW Exterior Concrete Block - Ext Ins(BEDROOM 4.1 29 0 8 0 232.0 ft2 0 0 0.5 0 3 W=>NE Exterior Concrete Block - Ext Ins(BEDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0 4 S=>NW Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0 5 N=>SE Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0 6 N=>SE Exterior Concrete Block - Ext Ind1lEDROOM 2 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0 7 NE=>S Exterior Concrete Block - Ext InfiEDROOM 2 4.1 2 10 8 0 22.7 ft2 0 0 0.5 0 8 E=>SW Exterior Concrete Block - Ext Infi&DROOM 2 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0 9 SE=>W Exterior Concrete Block - Ext In!fl&DROOM 2 4.1 2 10 8 0 22.7 ft2 0 0 0.5 0 10 S=>NW Exterior Concrete Block - Ext InfiEDROOM 2 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0 11 NE=>S Exterior Concrete Block - Ext Insul ENTRY 4.1 1 5 8 0 11.3 ft2 0 0 0.5 0 12 E=>SW Exterior Concrete Block - Ext Insul ENTRY 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0 4/17/2018 8:47 AM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 WALLS - --- -A -djaoenC - - -- - --- Space Cavity Width Tn VIA lypp Height Sheathing Framing Solar Below _ 13 S=>NW Exterior Concrete Block - Ext InsdIAUNDRY 4.1 6 0 8 14 N=>SE Exterior Concrete Block - Ext InsGREAT/DINI 4.1 28 0 8 15 W=>NE Exterior Concrete Block - Ext InsGREAT/DINI 4.1 20 0 8 16 N=>SE Exterior Concrete Block - Ext ImIIEDROOM 3 4.1 13 0 8 17 N=>SE Garage Frame - Wood BEDROOM 3 11 30 8 0 48.0 ft' 0 224.0 ft' 0 160.0 ft' 0 104.0 ft' 240.0 fF 0 0 0.5 0 0 0.5 0 0 0.5 0 0 0.5 0.23 0.5 0 0 0 0 0 DOORS # Ornt Door Type Space Stones U-Value Ft Width Height In Ft In Area 1 E=>SW Insulated ENTRY None .39 3 6 8 20 ft' WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Overhang Area Depth Separation Int Shade Screening 1 W-NE 3 Metal Low-E Single Yes 2 S=>NW 4 Metal Low-E Single Yes 3 E=>SW 8 Metal Low-E Single Yes 4 N=>SE 14 Metal Low-E Single Yes 5 W=>NE 15 Metal Low-E Single Yes 6 N=>SE 16 Metal Low-E Single Yes 0.63 0.25 N 0.63 0.25 N 0.63 0.25 N 0.63 0.25 N 0.65 0.21 N 0.63 0.25 N 32.4 ft' 1 ft 0 in 6.9 ft' 1 ft 0 in 23.2 ft' 1 ft 0 in 36.8 ft' 1 ft 0 in 40.0 8' 10 ft 0 in 16.2 ft' 1 ft 0 in 1 ft 4 in Drapes/blinds 1 ft 4 in None 1 ft 4 in None 1 ft 4 in None 1 It 4 in None 1 ft 4 in None Exterior 5 None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 300 fF 300 ft' 30 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1605.3 88.13 165.74 .2598 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 4/17/2018 8:47 AM EnergyGaugeO USA- FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 HOT WATER SYSTEM -- - - -#--System,Type -$ubType- Location-- -EF- --- Cap- -- - -Use-----SetPnt-- - ---Conservation - 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / — Supply — — Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 250 ft- Attic 65 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programablre'Thermostat: Ceiling Fans: Heating Jan ��Y [X] Feb Mar I [ ] j My rj Jun [X] Jul f [X] Aug r [X] Sep [ ] LJ Nov [rX,� Dec Venting [ I Jan L l [[ ]] Feb X Mar X Apr May Jun ll[ JJ1 Jul [[[ ]] Aug [[[ 1] Sep Lxl Octet [X] Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4/17/2018 8:47 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 i41R BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE ROYALE IMPACT Builder Name: WYNNE Street: WYNNE DEV. Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number. Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to . unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spat Bs. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electricallphone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover nlates and walls or cellinn. a. m aoonion, inspection or iog waits shall oe in accordance wim the provisions or IDD-000. 4/17/2018 8:47 AM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 'FORM R405-2017 -ENERGY PERFORMANCE LEVEL (EPL)__ DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. WYNNE DEV., FT. PIERCE, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1448.70 ft' b. Frame - Wood, Adjacent R=11.0 240.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 3 d. N/A R= ft' 5. Is this a worst case? yes 10. Ceiling Types Insulation Area a. Under Attic (Vented) R=30.0 1720.00 ft' 6. Conditioned floor area 1720 b. N/A R= ft' 7. Windows" Description Area c. N/A R= ft' a. U-Factor: Sgl, U=0.63 115.42 ft' 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic R ft' 6 250 SHGC: SHGC=0.25 b. U-Factor. Sgl, U=0.65 40.00 ft- SHGC: SHGC=0.21 12. Cooling systems kBtu/hr Efficiency c. U-Factor. N/A ft' a. Central Unit 34.8 SEER:15.00 SHGC: d. r: N/A ft' SHGC: SHGC: 13. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 3.316 ft. a. Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average SHGC: 0.240 8. Floor Types Insulation Area 14. Hot water systems a. Slab -On -Grade Edge Insulation R=0.0 1720.00 ft- a. Electric Cap: 40 gallons b. N/A R= fF EF: 0.97 c. WA R= fF b. Conservation features None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant feat Builder Signature: Date: Address of New Home:�2j�fy� '� rL Q City/FL Zip: S � osi p *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at'energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/17/2018 8:47 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 Project Summary Job: -- wrlghtsoft° Entire House By: ---- I- - -- -- - -QUICK CALCS, INC. - - — --- 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-46"796 Ertel PUICKCALCS@A0LC0M Project• • For. THE ROYALE WYNNE DEV., FT. PIERCE, FL Notes: \ Ja�g C� �Cei Weather. Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 19898 Btuh Ducts 6092 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 25990 Btuh Infiltration Method Construction quality Fireplaces Fort Pierce, FL US Simplified Average 0 Heatin Cool in . V�me (fta) 14231 142311 Airchangeslhour 0.38 0.20 Equiv. AVF (cfm) 90 47 Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A'030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat Capacity balance point = 35 OF Backup: 8.5 HSPF 34600 Btuh @ 47°F 27 OF 1160 cfm - 0.045 cfm/Btuh 0.50 in H2O Input = 7 kW, Output= 23009 Btuh, 100 AFUE Calculations Summer Design Conditions Outside db 90. OF Inside db 75 OF Design TD 15 OF Daily range Relative humidity L 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 18607 Btuh Ducts 9204 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier Equipment 0.95 sensible load 26420 Btuh Latent Cooling EquipmentLoad Sizing Structure 2182 Btuh Ducts 2516 Btuh Central vent (0 ofm) 0 Btuh (none). . Equipment latent load 4697 Btuh Equipment total load 31117 Btuh Req. total capacity at 0.70 SHR 3.1 ton Cooling Equipment Summary Make Carrier Trade CARRIERAIR CONDITIONING Cond 25HBC536A'030 Coil FX4DN B,F)037 AHRI ref 79145 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh. Actual airflow 1160. cfm Air flow factor 0.042 cfrr./Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.86 ACCA to meet all requirements of Manual J 8th Ed. wrightsofY Right -Suite® Untversal 201717.0.14 RSU08101 ...%Quick Calcs\Documents%WYNNE-ROYALS-REVISED.mp Calc=MJ8 Front Door faces: N 2017-Apr.10 17:29:34 Page 1 11 F wrightsoft Right-JO Worksheet Job: Entire House Date: sy: _. _QUICK CALCS,-INC. 31 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fa T72-466-6796 Email: QUICKCALCS@AOLCOM 11 Room name Entire House BEDROOM 2 6rposed wall 180.9 ft 52.0 ft 13 Raom height 8.3 ft d 8.0 ft heat/cool W Room dimensions 1.0 x 343.0 It i5 Room area 1719.5 ft- 343.0 ft' Ty CorlsUu16m U-lelue Or HTM Area (fly Load Area (ftj Load number (StuWft-F) (BtUWft2) or perimeter (ft) (Stuh) or perimeter (ft) (BtUh) Heat Cool Gross WPIS Heat Cool Gross WPIS Heat Cool 16 WAG -13A4= 0.143 -n 4.00 - 255 577 524 2096 1333 72 72 288 183 L--G-'4A5,2om 1Aclom 1.270 n - 35.56 34.77 16 0 565 M 0 0 - 0 0 0.770. It -ne 21.55 19.31 -38 0 815 730 0 0 0 0 w 13h4ocs 0143 400 255 34 34 136 86 0 0 0 0 1�1 %y 13A4= 0143 a 400 255 112 67 269 171 0 0 0 0 1Ac1om 1270.:e 35.58 -87.29 24 �3 848. .2082 0 0 0 0 zl-G LD 11D0' 0390 ep 1092;. 1131 r.r21 - _21 229 '238 ',0;- ,10 0 _:0 w 13A-4ocs 0143 se 400 255 23 23 91 58 0 0 0 0 V�I 13A-0acs 0143 s .. 400 -; - -Z55 `456 :' 449 --. 1798 , - 1143 232 - 232 _" 929 +591 r-�^- AAalom .r - - :.1.270 's - 35.56 - 34.77 -.:7 - 14 . '247 .241 :.0 ., '0 - 0 ..=0 V17 13A4xs 0.143 w 4.00 2.55 290 217 867 551 112 79 318 202 l�-GG 1Actom 1.270 w 35.56 55.25 33 4 1162 1806 33 2 1162 1806 4A5-2om 0..770 w 21.66 45.63 41 4 890 1862 0 0 0 0 P". ucC osvr. • - ... '_.. .' - 0 091 '. = .:: 255 _ ? 1.28 a224 - 224 671 t .. '28-7 A. 1 :0 :. '0 '. "�� 0 C 16A30md 0.032 - 0.90 232 1720 1720 1541 3989 - 343 343 307 796 F. `.:22A-to ' . 0.989 , - 27.0 . 0.00 . 1720 ` '181 ' 5010 - -0 .... _ . , `343 _ _ = 52 r.. 1440 - . - .,0 _ � c)AED eleurslan 465 668 Envelope loss/gain 17124 15595 4444 4245 1IL a) Infiltration 2774 782 773 218 b) Room ventilation 0 0 0 0 13 Internal gains: Oocupams aQ 230 1 230 0 0 Appfiencestother 2000 0 Subtotal(lines Etc 13) 19898 18607 5218 4463 Less e#ernal loatl 0 0 0 0 Less transfer 0 0 0 0 Re6stdhutlon 0 0 0 0 1 Subtotal 19898 18607 5218 4463 1� Duct loads 31% 49% 6092 9204 31% 49% 1598 2208 Total rcomloatl 25990 27810 6815 6971 Air required (cfm) 1160 1160 39 278 414- wrigIll Right-Su8e@ Universal 201717.0.14 RSU08101 ... \OWCk CalcslDocumentslwYNNE-ROYALE42EVISED.mp Calc=MJ8 Front Doorfaces: 2017-Apr1017:29:34 Page 1 wrightsoft' Right-JO Worksheet Job: Entire House Date: QUICK CALCS,_INC. By: 317 ST. LUCIE LN., FT. PIERCE. FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: OUICKCALCS@AOL.COM 1 Room name WIC M. BATH 2 Egxrsedwall 0 ft 8.0 ft 3 Room height 8.0 ft hwVcool &0 It heaVcotl 4 Room dimensions 7.0 x 9.0 ft 7.0 x 8.0 It IS Room area 63.0 ft2 56.0 ft2 j Ty Construction U-value Or HTM Area (ft9 Load Area (ft2) Wad nurnber (BtulJft-F) (Btwft2) or perimeter (it) (Btuh) or perimeter (ft) (Btuh) Heat T Cool Gross N/P/S Heat Cool Gross WP/S Heal Cool - 6 VjI .13A-0acs- 0.143 n 4.00 - 2.55 0 0 0 0. 0 0 0 0 1Aclon 1:270 n 35.56 34.77 0 0 0 0 - 0.. 0 0 0 4AS-2om 0.770 n 21.56 19.31 0 0 0 0 0 '0 0 0 w 13A-4= 0.143 no 400 2.55 0 0 0 0 0 0 0 0 11 13Ar4acs 0.143 a 400 255 0 0 0 0 0 0 0 0 -.1Actan 1:270 a- - 3556 :87.29. 0 0 0. 0 - 0 0 0 �o _ 1100-' - 0.390. e, - 1092 '11:31--. ..- '0 0` 0... ,0 - _..0: :.0 0:-::-.``.0 .w 13AAoos 0.143 as 4.00 - 255 0 0 0 0 0- 0 0 0 Vy 13Aaocs ;' 0.143 4.00 22.55 - ` 0 0 , ' : ' �.:0 . .. 0 "64 « - . 57 - _. 228 _'-145 :1Aclam ' - '1.270 a "35.56 ' 34;77 .0 o I. 0." 0 7.. 7 247 241 y! 13A4= 0.143 w 400 265 0 0 0 0 0 0 . 0 . 0 IL--fC 1Aclon 1.27o w 3556 5&25 0 0 0 0 0 0 0 0 4A5-2am 0.770 w 21.56 45.63 0 0 0 0 0 0 0 0 P- , -?- -M2C41sw�„ ;.:.. - i C.091 . - `, y265 ;.- 1.28 , ; 0 ,.:. - 0 - ...:0 . 0 ` :.. 0 - .0 ' 0 .. " ._..'0 i C 16A30md 0.032 - 0.90 Z32 63 63 56 146 56 56 50 130 j F- d; i 22A-tpl .0.989 - 27.69 :. 0.00 .. 63 .0 '0 0', -56 " 8 .222 6 c)AED elxursion -10 39 Envelope loss/gain 56 136 747 477 12 a) Infiltration 0 0 119 34 _ 1 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Applianceslother 0 0 Subtotal (fines 6to 13) 56 136 666 511 Less ademal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 11 Subtotal 56 136 866 511 151 Duct loads 31% 49% 17 67 31% 49% 265 253 Total mom load 74 203 1131 764 Air requlred(cfm) 3 8 50 32 -tj� wrightsoft- RightSufte® Universal 201717.0.14 RSU08101 ... IOuick CalcslDocumentslWYNNE-ROYALE-REVISED.mp Calc=MJ8 Front Doorfaces: 2017-Apr-10 17:29:34 Page 2 i wrightsoft- Right-M Worksheet - Entire House -QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL S4946 Phone: 7724665799 Faz 772-466-6796 Emil: QUICKCALCS@AOLCOM Job: Date: By: Room name 19TCHEN BATH 2 El ad wall 0 ft 5.0 ft Raom height 8.0 ft heat/cool 8.0 ft heWcool 13 4 Room dimensions 1.0 x 1720 ft 9.0 x 5.0 ft �5 Room area 172.0 fP 45.0 ft' Ty Construction U-value Or HTM Area (" Load Area Load numbrr (Btuwfti°F) or. perimeter (ft) IBM) or perimeter (ft) (Btuh) Heat Cool Gross NIP/S Heat Cool Gross NIP/S Heat Cool �13AA= 0.143 n 4.00 Z55 0 0 0 0 40 40 160 102 �6 1-_, tAclown 1.270 n 35.55 34.77 0 0 0 0 0 0 .0 0 4AS-2an - 0.770 . n 21.55 19.31 0 0 0 0 0 0 0 - 0 w 13AAccs 0.143 ne 400 255 0 0 0 0 0 0 0 0 11 13A-08cs 0.143 a 400 255 0 .0 0 0 0 0 0 0 F---G. ;1Aotan. -' 1:270 a 35.56 BZ29 0 .0 0 0- 0 - 0 0 .0 1=-D 91D0 . 0.390 s-e •10.92 =<11:31 0 -. 0 0. .0 -0 .. ,0 - 0 - '. 0 w 13A4= 0.143 se 4.00 255 0 0 _ 0 0 0 0 0 0 yy .13A4= - .0.143 -a- > 400 -. 265 - '0 . , 0' -. 0 •0 -0 "- .'0 0 `=o L--C-'1Ac1an -._ -: 1..270: s .-�•.35.5s , 34,77 .- :o r: - 0 -'.-. - .0.' 0 • 0 + . 0... 0 . ' 0 VI! 13A-4= 0.143 w 4.00 255 0 0 0 0 0 0 0 0 tAclom 1.270 w 35.56 55.25 0 0 0 0 0 0 0 0 L�GC 4A5-2cm 0.770 w 21.56 45.63 0 0 0 0 0 0 0 0 P 12C-05w 0.091 ..- "2.55 ,ts28 .'6A i;: -64 163 :: 82 .. - _0- ,0'. 0:- ;-.0 i C 16A30md 0.032 - 0.90 232 172 172 154 399 45 45 40 104 I P' •. I F '22A4PI _ - C.989 - -.27.69 '. -0.00' '172 0 .'0 :0" :45".. S. 138 :, "0 I 6 c)AlD ercurslon -176 -16 Penelope loss/gain 317 305 339 190' 12 a) Infiltration 0 0 74 21 b) Room ventilation 0 0 0 0 73 Internal gains: Occupants @ 230 0 0 0 0 Applianceslother 2000 0 Subtafal pines 6 to 13) 317 2305 413 211 Less eldemzl load 0 0 -0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 1 Subtotal 317 2305 413 211 1§ Duct loads 31 % 499/6 97 1140 31 % 490/6 127 104 Total room load 414 3446 540 315 Air required(drn) 18 144 24 13 f}} wrightsoft- RlghtSuite® Universal 2017 17.0.14 RSU08101 ...lQuick CalcslDocumentslwYNNE-ROYALE-REVISED.mp Cola = MJ8 Front Door faces: N 2017-Apr-10 17:29:34 Page 3 wrightsofr ight-JO Worksheet 2Entire House `QUICK CALCS,-INC. 31F ST. LUCIE LN, FT. PIERCE, FL 34M Phone: 772-466.6799 Fax 772-466-6796 Emil: QUICKCALCS@AOL.COM Job: Date: By: 1 Room name BEDROOM 2 ENTRY 2 E�osedwell 426 ft 6.3 ft 3 Rocm height 8.0 ft heat/cool 8.0 ft heaU000l 4 Room dimensions 1.0 x 204.0 ft 1.0 x 97.5 ft 5 Room area 204.0 W 97.5 ft Ty Construction U-value Or HTM Area Load kea number (BtuNft� F) (Btu[Vft2) or perimeter (ft) (Btuh) a perimeter (ft) (&uh) Heat Cool Gross N/P!S Heat Cool Gross WP/S Heat Cool - �6 - 13A-0acs 0.143 n 4.00 255 112 1.12 448 285 0 0 0 -0 1Ac1om -4A5.2om 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0 0.770 n 21.56 - 19.31 0 0 0 0 0 0 0 0 W 13q-00cs 0.143 ne 4.00 255 23 23 91 58 11 11 45 29 11 VV 13AAa 0.143 e - 4.00. 265 .72 48 193 123 40. 19 76 48 111c1om - .-1.270 e • 35.56 87:29 :24 2. - 848-. 2082 0 _ 0 0 -_'. o :1100 . .. - -0.390 w 10.92 - -11.31 - .0 -. -.0 - 40 -0 21 21 229 ; 238 w 13AAocs 0.143 se 4.00 2.55 23 23 91 58 0 0 0 0 1N � 13NA6cs = ". __ 0.143 - s ' ' 400 - -265 112 - . - 112 - -..448 285 - . "+0' -0 0 - ;"p 1-1a 1Aciom -1.270 s . .95.56 •:-34.77 .o o =: 0 o - o j .o .o'-..o Vf/ 13AAccs 0.143 w 4.00 255 0 0 0 0 0 0 0- 0 1Aclom 1.270 w 35.56 55.25 0 0 0 0 0 0 0 0 ll---GG 4A5-2nm 0.770 w 21.56 45.63 0 0 0 0 0 0 0 0 ` ..• w ,, ; .0.091 , - 255 1.28 �,. '0 .. 0.. -. 0 :' 0 - - 104:.' - 404 -'265 ::.. -; 133 C 16A-30md 0.032 - 0.90 232 204 204 183 473 98 98 87 226 F... 22&tpl 0.989: - 27.69 ' 0.00 204 •. 43 ` 1179 0 ..98 i6 175 8 c)AED extrusion -gp _Sp Envelope loss/gain wi 3273 878 625 12 a) Infiltration 634 179 95 27 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Applianceslother 0 0 Subtotal Gins 6 to 13) 4115 3452 974 651 Less e#erral load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 4115 3452 974 651 15 Duct loads 31% 49% 1260 1708 31% 49% 298 322 Total mom load 5376 6159 1272 974 Air required(cfm) 240 215 57 41 -F'4' wrighttsoR- Right-SuiteO Universal 201717.0.14 RSU08101 ...\Quick Calm\Documents\WYNNE-ROYALE-REVISED.mp CaIc=MJ8 Front Doorfaces: 2017-Apr-10 17:29:34 Page 4 wrightsoft' Right-M Worksheet j Entire House 1 _ .QUICK.CALCS, INC. 3' 7 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-4666799 Fax 772-4666796 Email: QUICKCALCS@ADL.COM Job: Date: By: 11 Room name LAUNDRY GREAT/DINNG 12 EVosed wall 6.0 It 48.0 ft Room height 8.0 R heaVocol 8.9 It heat/ood I3 4 Room dimensions 7.0 x 6.0 if 1.0 x 528.0 ft �5 Room area 420 ft- 528.0 ft2 Ty Constructim U-value Or HTM Area (112) Load - Area (ft2) Load number (BtuwWF) (BtuNft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NIPIS Heat Cool Gross N/P/S Heat Cool I !6 13A-4= 0.143 n 4.00 255 0 0 0 0 249 211 846 538 1A•ciom - 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0 �. '4A5¢om 0.770 ' n 21.56 19.31 0 0 0 0 38 0 '815 730 :. w 13A-0acs 0.143 ne 4.00 255 0 0 0 0 0 0 0 0 11 13A-4= 0.143 a 4.00 255 - 0 0 - 0 0 0 0 0 0 4Aclom 1.270 e - 35.66 87.29 0 0 0 0 0 0 0- .0 -11D0. _ 0390, e• 10.92 _. "11.31 0 0` 0 0:. 0' ::- 0 0� 0 w 13A4as 0143 as 400 2.55 0 0 0 0 0 0 0 0 13A4ocs -- ... 0143 s - _ .. , 4 00 ,: 255 " 48 . - 48 - 192 122 0 , - 0 1Ac1an'." '.1270 s :-35.56 '34.77' :0 -'0 0 -.i0 :0' .0" 0 13A4ocs 0143 w 400 255 0 0 0 0 178 137 549 349 1Ac1. 1z70 w 3556 55.25 0 0 0 0 0 -0 0 0 4A5-20m 0.770 w 21.66 45.63 0 0 0 0 41 2 880 18K P'.} - '.12C-0swp. :. ..-0.091 . -., - '255 - :; '. 128 .. - 56 -: .- 56 ,- " :143 " 72 - . .-0 . :' ..0 - "0 ;; ,... >o C 16AS0md 0.032 - 0.90 232 42 42 38 97 528 528 473 U25 I i 'F.. . E 22A4pl - - 0.989 , - -27.69 -_ . '0.00 - "42 6 .166 0 .528 %. 48 .. 1329 ; .. , 0 c)AEE exCasion. -22 305 Envelope lass/gain 539 269 4893 5008 12 a) Infiltration 89 25 794 224 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal Ames 6 to 13) 628 294 5697 6232 Less eMemal lead - 0 0 0 0 Less booster 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 628 294 5687 5232 15 Duct loads 31% 49% 192 146 31% 49% 1741 2588 Total room load ffi0 440 7428 7ffi1 Alr required(cfm) 37 18 .2 326 41-11- wrightsoft, RlghtSuReO Universal 201717.0.14 RSU08101' ..AQulck CaIcslDWc ntslwYNNE-ROYALE-REVISED.wp Calc = MJB Front Door faces: 2017-Apr-10 17:29:34 Page 5 fr Right M) Worksheet Entire House QUICK CALCS,-INC. ST., LUCIE A, FT. PIERCE, FL 34946 Phone: 772466.6799 Fax 772466-6796 Emil: OUICKCALCWOL.COM Job: Date: By: I1 Ran nane BEDROOM 3 2 wall eight 1&0 ft 3 Room 8.0 It heat/cool I4 Room dimensions 13.0 x 1&0 it ,5 Room area 169.0 ft- Ty Constructim U-telue Or HTM Area (ft2) Load Area Load number (BtuWftx°F) (BtuhIM or perimeter (ft) (Btuh) or perimeter Heat I Cod Gross WP/S Heat Cool Gross WP/S Heat Coal 6 . Vy�—G 13A4ocs 0.143 n 4,00 2.55 104 88 353 224 lWom 1.270 n 35.56 34.77 16 0 665 553 --G 4l5-2am 0.770 . n 21.56 19.31 0 0 0 0 W 13AA= 0143 ne 400 255 0 0 0 0 11 13A4= 0143 a 400 - 255 0 " 0 0 0 I--G tAclom" 1270 :a. 3556 87.29 0 -0 0 0 III----0-0-0.11DD--.,'.0390 ;0.. .. ..1092 ',...tti31 .ti p, " 0 "0 W 13A-0acs 0143 se 400 255 0 0 - 0 0 yyy�I � 13A 46ci.. 0143 s - _ 400 _ %Z65 ... .0... 0 _ :.•D ,p -. c1—C 1A61orn .1270 s : ' 3556 - 34,77 .. 0 0 .' 0 0 - 13A4ocs 0143 w 400 2.55 0 0 0 0 1Aclom 1270 w 3556 55.25 0 0 0 0 4A5-2om 0.770 w 21.56 45.63 0 0 0 0 P : ':: '12C-0sw•...;_ ': - '0.091 . 2.55 '. ;1-28 D - - 0 ... '.;0 0 - C 16ASomtl 0.032 - 0.90 2.32 169 169 151 . 392 I 1 F-' .. 22A-tpl' _ _ . 0.989; _ :' '27.69 - - oab - .169 - 73.. 360 0. . I 6 c)AED excurslm -103 EJ lope loss/gain 1430 1066 12 a) Infiltretian 193 55 - b) Room ventilation 0 0 13 traemal gains: Occupants Q 230 1 230 Appfiarceslother 0 Subtotal (lines 6 to 13) 1623 1351 Less ertemal load p 0 1 Less transfer 0 0 Redistribution 0 0ubt 14 Sotal 1623 1351 15 Duct loads 31% 49% 497 668 Total room load 2120 2019 Air required(cfm) g5 8q wrightsoft- RlghtSuHe® Universal 201717.0.14 RSU08101 ... 1Qulck CalcslDmuments%VMNE-ROYALS-REVISED.rup Calc = MJ8 Front Doorfaces: 2017-Apr-10 17:29:34 Page 6 + wrightsoft° Duct System Summary Entire House QUICK CALCS, INC. ST. LUCIE LM, FT. PIERCE, FL 34946 Phone: 77246"799 Fax 772-466.6796 Emil:. OOICKCALCS@AOLCOM For. THE ROYALE WYNNE DEV., FT. PIERCE, FL nal static pressure lure losses able static pressure ly/ return available pressure st friction rate it air flow effective length (rEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.286 in/100ft 1160 cfm Job: Date: By: Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.286 in/10Oft 1160 cfm 175 ft i Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (In) H x W (in) Duct Mat] Actual Ln (ft) Ftg.Egv Ln (ft) Trunk i ATM h 540 24 13 0.351 4.0 NO VIFx 27.3 115.0 st1 BEDROOM h 3408 152 139 0.286 7.0 0x0 VIFx 40.1 135.0 st2 BEDROOM 2 h 5376 240 215 0.343 7.0 OxO VIFx 30.8 115.0 st1 BEDROOM 3 h 2120 95 84 0.371 6.0 OxO VIFx 19.9 115.0 st1 BEDROOM -A h 3408 152 139 0.297 7.0 OxO VIFx 33.1 135.0 st2 ENMY h 1272 57 41 0.485 4.0 Ox0 VIFx 8.1 95.0 GREAT/DIMNGA h 3714 166 163 0.300 7.0 Ox0 VIFx 31.7 135.0 st2 ,GREAT/DIMNGB h 3714 166 163 0.309 7.0 Ox0 VIFx 27.1 135.0 st2 KITCHEN c 3446 18 144 0.376 7.0 Ox0 VIFx 18.1 115.0 st1 uUNDRY h 820 37 18 0.369 4.0 Ox0 VIFx 20.4 115.0 st1 M. BATH h 1131 50 32 0.366 4.0 OxO VIFx 21.6 115.0 sH wIc c 203 3 8 1 0.309 4.0 Ox0 VIFx 26.6 135.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct (Name Type (cfm) (cfm) FR (fpm) (n) (in) Material Trunk st2 Peak AVF 639 613 0.286 814 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1103 1119 0.286 802 16.0 0 x 0 VInIFIX I Wrl htsoft` 2017-Apr.1017:29:35 9 RightSuite® Universal 2017 17.0.14 RSU08101 Page 1 ...kQuick CalcslDmuments%WYNNE-ROYALE-REVISED.mp Calc=MJB Front Doortaces: N i ame Grille— Siie (in) -Htg (cfm) Clg (cfm) TEL (ft) Design . FR Veloc (fpm) Diann (in) H x W (in) Stud/Joist Opening Qn) Duct Mat] Trunk obi NO 1 1160 1160 0 0 0 0 Ox 0 VIFx Wrl htsOtt' ton-Apr-1017:29:35 9 RightSo0e0 Universal 2017 17.0.14 RSU08101 Page 2 ...\Quick Cale\DxumentslWYNNE-ROYALE-REVISED.mp Calc=MJ8 Front Door faces: N