BLOWER DOOR TEST FORM I ST. Lucie County, Permitting
House Infiltration Test Certification 3-A[YNE®
Prescriptive AndPerformanceMethod
Date: �a Permit#: 0&05
Contractor:
Job Address: q q-22t m 4A o w D (9 C 1 Rz'r
Construction: ('�.) New Construction - Complete ( ) Existing -After Addition
House InfiltratioriTest Resyllts SLC Climate Zone 2 —{
CFM (50) = o�C OvCC Test Date: 10 to q
Volume = —7 -) " 7
ACH (50) = CFM (50) x 60 / Volume = 41 Sr Mechanical Ventilation required less than 3 ACH
Passing results must be & ACH (50) or less ( Pass ( ) Fail
FBC, Energy
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through B. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be" conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as setforfh in Section 489.305 (3)(f), (g) or (i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
FBC, Residential
Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Testing Company Company Name: G� r A Address: / ! [)—�jWCnmOcz 4, D
�� "� y_
fli—
I hereby certj4 that the above House Infil ratio results demonstrate compliance with FBC Energy Conservation
requirements i accordan�a(ith Section 4.1.2 Climate Zone 2.
Printed: �TLA;�ZCp Ghc ce—V
License/Certification#: 6f � �-a& 2 �9a