Loading...
HomeMy WebLinkAboutCERTIFIATION FOR DESIGN LOAD COMPLIANCEPlanning & Development Services Department Ilk- VFO 2300 Virginia Avemfe, Fort Pierce, FL 34982 - (772) 462ed�,t5t3 _ «/9 F �� Certification for Design Load Compliance $f Ce °u bent r A p C'. M Project Name: Permit#: Occupancy Type: Construction INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. ' Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2017 Building Code Fifth Edition with 20 NIA Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open S. Risk Category: _I X II _III _ IV Exposure Category: _B X C _D 4. Design Wind Velocity 160 a mph X ASD _LRFD End Zone Width: 6 ft 5. Mean Roof Height t V ft Roof Pitch: 6 :12 Parapet: NSA ft 6. Components & Cladding Design Pressures Used: (PSF. based on 10sgh 1S'MRH, dearly labs on all plan openings): It-M • 0 rZB, 0 s 0 1Z ri! 9^3Y ;P J-z-Ir- r Zone 1: -S/3 Zone 2: —5-�_,� Zone 3: " 94 -Z Zone 4:-3 h 6 Zone 5: -'r- `f .rGarage: -- 5y..4 7. Design Loads: Floor, t00 PSF Roof/Dead: 12 PSF Roof/Live: 30 Balcony: wA PSF Dock: NIA PSF Deck: NIA PSF Stairs: NSA PSF Fence: N/A PSF Railings: N/A PSF 8. Were Shear Walls Considered For Structure? _Yes 4LNot Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design farces sp ' ie .i �J "t3` 521JY � Print Name Cert # & Co. Cert Auth. sc✓ re, Date, i('nd Skal _ © .Sff; /,/ C1 F r-e-1 Company Name & Address A n T® V