HomeMy WebLinkAboutENERGY EFFICIENCY CODEI
FORM R405-2017
FILE COPY
FLORIDA ENERGY-EFFICIENCY-CODE-FOR-BUILDING-C-ONST-RUC-T-ION-
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: MW-266
Builder Name: GHO HOMES
Street: 3012 BENT PINE DR
Permit Office: ST. LUCIE COUNTY BLDG
DPTm8CA1Vyg0
C
City, State, Zip: FORT PIERCE, FL,
34951
Permit Number.
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
County: ST. LUcie (Florida Climate Zone �Ucfe County
1. New construction or existing
New (From Plans)
9. Wall Types (2429.8 sgft.)
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.0 2120.10 ft'
b. Frame - Wood, Adjacent
R=11.0 309.78 ft'
3. Number of units, if multiple family
1
c. N/A
R= ft'
4. Number of Bedrooms
3
d. N/A
R= ft'
5. Is this a worst case?
No
10. Ceiling Types (2327.0 sqft.)
Insulation Area
a. Under Attic(Vented)
R=30.0 2327.00 ft'
6. Conditioned floor area above grade (ft')
2327
b. N/A
R= ft'
• Conditioned floor area below grade (W)
0
c. N/A
R= ft'
_
11. Ducts
R ft'
7. Windows(387.7 sgft.) Description
Area
a. Sup: Attic, Ret: Attic, AH: Main
6 875
a. U-Factor: Dbl, U=0.62
387.66 ft'
SHGC: SHGC=0.26
b. U-Factor: N/A
ft'
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
48.0 SEER:16.00
- c. U-Factor: N/A
ft'
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A
ft'
a. Electric Strip Heat
29.5 COP:1.00
SHGC:
Area Weighted Average Overhang Depth:
0.000 ft.
Area Weighted • Average SHGC:
0.260
14. Hot water systems
8. Floor Types (2327.0 sqft.)
Insulation Area
a. Electric
Cap: 50 gallons
a, Slab -On -Grade Edge Insulation
R=0.0 2327.00 ft'
b. Conservation features
EF: 0.900
6. N/A
R= ft'
None
c: N/A
R= ft'
15. Credits
Pstat
Glass/Floor Area: 0.167
Total Proposed Modified Loads: 76.78
PASS
Total Baseline
Loads: 78.23
- 1 hereby cell that the tans and specifications covered by
Review of the plans and
FSiIE STgls
this calculation a in c pN nce ith the Florida Energy
specifications covered by this
10.
Code.
calculation indicates compliance
with the Florida Energy Code.
m,> ".`.:?rt;'. 4 ;r �O
PREPAREDIBYi
Before construction is completed
a O
DATE:
this building will be inspected for
compliance with Section 553.908
B
'nce
,I hereby certify th s uil i stg777
Florida Statutes.
with the Florid nergy C,o e.
SOD (RV
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
Compliance requires certification b the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
i
Y
f i 1/17/2019 10:48 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 4
f-'
,*
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
" Permit Office:
Jurisdiction:
.Family Type:
' New/Existing:
Comment:
MW-266 Bedrooms: 3
User Conditioned Area: 2327
Total Stories: 1
1 Worst Case: No
GHO HOMES Rotate Angle: 0
ST. LUCIE COUNTY BLDG D Cross Ventilation: No
Whole House Fan: No
Single-family
New (From Plans)
Address Type:
Lot #
Block/Subdivision:
PlalBook:
Street:
County:
City, State, Zip:
Street Address
3012 BENT PINE DR
ST. LUcie
FORT PIERCE,
FL, 34951
CLIMATE
_ /
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75 - 299
62 Low
BLOCKS
"Number
Name
Area Volume
1
Blockt
2327 21641.1
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled Heated
1
Main
2327 21641.1 Yes 4
3
1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 213.6 ft 0
2327 fF
___
0 0 1
ROOF
_/
V #
Type
Roof Gable Roof
Materials Area Area Color
Solar
Absor.
SA Emitt
Tested
Emitl Deck Pitch
Tested Insul. (deg)
1
Hip
Flat Tile/slate 2602 ft' 0 ft' Medium
0.4
N 0.9
No 0 26.6
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 150 2327 ft-
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
2327 ft- 0.1
Wood
s„
1/17/2019 10:48 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 4
allillilly-1
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space
Cavity Width
Height
Sheathing Framing Solar
Below
--Amt
TO
WAILType
a-tialua Fr n-F7In
Area
R-t/mlue-Eractioa-.Absor_-GradeO04
_ 1 N
Exterior
Concrete Block - Ext Insul
Main
4 55
0 9
4
513.3 ft-
0
0 0.3
0
-2 E
Exterior
Concrete Block - Ext Insul
Main
4 65
8 9
4
612.9 ft-
0
0 0.3
0
_ 3 S
Exterior
Concrete Block- Ext Insul
Main
4 64
1 9
4
598.1 ft-
0
0 0.3
0
_ 4 SW
Exterior
Concrete Block - Ext Insul
Main
4 2
11 11
4
33.1 ft-
0
0 0.3
0
_ 5 W
Exterior
Concrete Block - Ext Insul
Main
4 32
0 11
4
362.7 ft-
0
0 0.3
0
6 -
Garage
Frame - Wood
Main
11 27
4 11
4
309.8 ft2
0
0.25 0.3
0
DOORS
- #
Omt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
W
Wood Main
None
.39
3
8
24 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V #
Omt ID
Frame Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
n
1
Metal Double (Clear)
Yes
0.62 0.26
N
21.3 ft-
0 ft 0 in
0 ft 0 in
None
None
2
n
1
Metal Double (Clear)
Yes
0.62 0.26
N
43.3 ft2
0 ft 0 in
0 ft 0 in
None
None
3
n
1
Metal Double (Clear)
Yes
0.62 0.26
N
9.0 ft2
0 ft 0 in
0 ft 0 in
None
None
4
e
2
Metal Double (Clear)
Yes
0.62 0.26
N
43.3 ft2
0 ft 0 In
0 ft 0 in
None
None
5
e
2
Metal Double (Clear)
Yes
0.62 0.26
N
112.4 ft2
0 ft 0 in
0 ft 0 in
None
None
6
e
2
Metal Double (Clear)
Yes
0.62 0.26
N
31.6 ft2
0 ft 0 in
0 ft 0 in
None
None
7
e
2
Metal Double (Clear)
Yes
0.62 0.26
N
6.5 ft-
0 ft 0 in
0 ft 0 in
None
None
_ 8
s
3
Metal Double (Clear)
Yes
0.62 0.26
N
6.5 ft2
0 ft 0 in
0 ft 0 in
None
None
9
s
3
Metal Double (Clear)
Yes
0.62 0.26
N
12.0 ft2
0 ft 0 in
0 ft 0 in
None
None
10
sw
4
Metal Double (Clear)
Yes
0.62 0.26
N
16.0 ft2
0 ft 0 in
0 ft 0 in
None
None
11
w
5
Metal Double (Clear)
Yes
0.62 0.26
N
48.0 ft2
0 ft 0 in
0 ft 0 in
None
None
12
w
5
Metal Double (Clear)
Yes
0.62 0.26
N
8.0 ft2
0 ft 0 in
0 ft 0 in
None
None
13
w
5
Metal Double (Clear)
Yes
0.62 0.26
N
8.0 ft2
0 ft 0 in
0 ft 0 in
None
None
14
W
5
Metal Double (Clear)
Yes
0.62 0.26
N
21.7 ft2
0 ft 0 In
0 ft 0 in
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
68.6 ft2 68.6 ft2
64 ft
9.3 ft
1
INFILTRATION
# Scope
Method SLA
CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse
Proposed ACH(50) .000295
1803.4 99.01
186.19
.224
5
1/17/2019 10:48 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 4
1 P
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Efficiency
Capacity
Block
Ducts
1 Electric Strip Heat/
None
COPA
29.48 kBlu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
SEER: 16
48 kBtu/hr
1440 cfm
0.7
1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric None
Garage
0.9 50 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Carl # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft'
DUCTS
d / —Supply—
V # Location R-Value Area
—Return
Location Area Leakage Type
Air
Handler
CFM 25 CFM25
TOT OUT
ON
RLF
HVAC#
Heat Cool
1 Attic 6 875 ft-
Attic
767 ft' Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
r CoolingrD0' Jan rDC,t Feb rDO, Mar
Heat!
[ ]Jan [ ] Feb [X] Mar
Ceiling Fans:
r Apr rr Ma rrXli Jun rrX Jul
Apr [ May [ ] Jun [ i Jul
rr Augrr
[1 Aug
Se r
[ Sep
Ocl
Oct
rDO, Nov
[X] Nov
rr Dec
[ Dec
Thermostat Schedule: HERS 2006 Reference
Schedule Type 1
2 3
Hours
4 5 6 7
8 9
10
11
12
Cooling (WD) AM 78
PM 80
Cooling (WEH) AM 78
PM 78
Heating (WD) AM 66
PM 68
Heating (WEH) AM 66
PM 68
78 78
80 78
78 78
78 78
66 66
68 68
66 66
68 68
78 78 78
78 78 78
78 78 78
78 78 78
66 66 68
68 68 68
66 66 68
68 68 68
78
78
78
78
68
68
68
68
78 80
78 78
78 78
78 78
68 68
68 68
68 68
68 68
80
78
78
78
68
68
68
68
80
78
78
78
68
66
68
fib
80
78
78
78
68
66
68
66
r
MASS
Mass Type
Area
Thickness Furniture Fraction Space
Default 8 Ibs/s .ft.
0 ft'
0 ft
0.3
Main
Name: Signature:
Rating Compant: Date:
1/17/2019 10:48 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (FromPlans)12.
Ducts, location & insulation level
a) Supply ducts R
6.0
• 2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location Attic/Attic
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 3
13. Cooling system: Capacity
48.0
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5. No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 2327
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a. 0.620
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.260
14. Heating system: Capacity
29.5
c) Area
7c. 387.7
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a. NA
d) Gas furnace, natural gas AFUE
• b) Solar Heat Gain Coefficient (SHGC)
8b. NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and Insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
- 2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
9a. 0.0
9b.
9c.
10A1.
10A2. 4.0
15. Water heating system
a) Electric resistance EF 0.90
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF_
f) Heat recovery unit HeatRec%
g) Other
1061. 11.0
10B2.
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
11a. 30.0
b) Cross ventilation No
11b,
c) Whole house fan No
11c,
d) Multizone cooling credit
11d. No
e) Multizone heating credit
f) Programmable thermostat Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has cot
saving features which will be i
display card will be completed
Builder
Address of New Home:
vith the Florida Building Code, Energy Conservation, through the above energy
(or exceeded) in this home before final inspection. Otherwise, a new EPL
on installed code compliant features.
Date: B
City/FL Zip: FORT PIERCE, FL 34951
1/17/2019 10:49:01 AM - EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
wri htsoft• Load Short Form Job:
9 Date: Dec24,2018
(Rest -of -House)— av
For. MW-286
9431 MEADOWOOD DR, FORT PIERCE, FL 34951
Design• •
Htg Clg Infiltration
Outside db (OF) 43 91 Method Simplified
Inside db(aF) 70 72 Construction quality Average
Design TD (OF) 27 19 Fireplaces 0
Daily range - L
Inside humidity (%) 30 50
Moisture difference (gdlb) 0 65
HEATING EQUIPMENT
Make
Trade
Model
AHRI ref
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
100 EFF
8.2
kW
27866
Btuh
16
OF
1550
cfm
0.056
cfm/Btuh
0
in H2O
COOLING EQUIPMENT
Make Carrier
Trade 16 SEER PURON AC
Cond CA16NA048"'•A
Coil FV4CNB006
AHRI ref 4585139
Efficiency 14.0 EER,
Sensible cooling
Latent cooling
Total cooling
Actual airflow
Air flow factor
Static pressure
Load sensible heat ratio
16 SEER
32550 Btuh
13950 Btuh
46500 Btuh
1550 cfm
0.043 cfm/Btuh
0 In H2O
0.76
ROOM NAME
Area
(fla)
Htg load
(Btuh)
Clg load
(Btuh)
Htg AVF
(cfm)
Clg AVF
(cfm)
FOYER
72
1637
1291
92
56
DINING ROOM
150
2235
2359
125
102
LAUNDRY
82
1313
1617
74
70
BED 3
182
2270
2374
127
102
BATH 2
83
954
844
54
36
BED 2
172
1972
2144
ill
92
FAMILY ROOM
459
9080
10892
510
469
KITCHEN
225
231
1660
13
72
BREAKFAST
113
3294
3354
185
144
LIVING ROOM
259
4340
8623
244
371
HALL
198
203
258-
11
11
POWDER
44
45
172
3
7
mr:nw 1
ao
en
ene
n
.v
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2018-Doo-V 08:34:44
AL WrightSOftRightso8e®Untvoreal2o1212.1.05RSUo2818 Pagel
AMCAU98MUasen\Doeomon1S%Wrlghboft HVACWW-280.wp Cale-W8 Front Door laces: SE '
(Rof House)
2079
27613
36981
1550
Oest eraqup 0a s
0
_
0
1550
-
Equip. @ 0.95 RSM
34362
Latent cooling
11158
TOTALS
9n7Q
9794
-•-•� -rvvcv iavv - IDov
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2018&Dw2708:34:44
Ae&C wrightsofir WghISuRe® UNveraa1201212.1.05 RSU02818 Fage2
G1Ua Uaao TmmsWWrighbcft WACNWd80.mp Cala=MIS Front Doorfama:SE
Load Short Form
For. MW-286
. 9431 MEADOWOOD DR, FORT PIERCE, FL 34951
Job:
Date: Dee 24, 2018
Htg Clg Infiltration
Outside db (`F) 43 91 Method Simplified
Inside db (°F) 70 72 Construction quality Average
DesignTD.CF) _ 27 19 Fireplaces 0
Daily range L
Inside humidity (%) 30 50
Moisture difference (gr/Ib) 0 65
HEATING EQUIPMENT
Make
Trade
Model
AHRI ref
Efficiency
Heating Input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
COOLING EQUIPMENT
Make
Carrier
Trade
16 SEER PURON AC
Cord
CA16NA018•"'A
Coil
FV4CNF002
AHRI ref
4583820
100 EFF
4.3
kW
14592
Btuh
21
OF
643
cfm
0.044
cfm/Btuh
0
In H2O
Efficiency
Sensible cooling
Latent cooling
Total cooling
Actual air flow
Air flow factor
Static pressure
Load sensible heat ratio
14.0 EER, 16 SEER
13510 Btuh
5790
Btuh
19300
Btuh
643
cfm
0.049
cfm/Btuh
0
In H2O
0.72
ROOM NAME
Area
Htg load
Clg load
Htg AVF
Clg AVF
(f 2)
(Btuh)
(Btuh)
(cfm)
(cfm)
MASTER SUITE
332
5019
5824
221
283
HER WIC
69
1188
622
52
25
MECH_2
23
535
693
24
34
MASTER BATH
290
6196
4212
273
204
DEN
153
1624
1843
72
89
HIS WIC
42
40
156
2
8
MASTER AHU
908
14602
13250
643
643
Other equip loads
0
0
Equip. @. 0.95 RSM
12654
Latent cooling
5048
TOTAI R
ono
4ecnn
nwn.,
I �.M
.....
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
Al wrighttSOft' RighlSuile®Unlversa1201212.1.05R5U02618 zoleomzroeaa:
44 Page
3
C:1U5arsUe30nl00wmenl51WrighLs°tt HVACIMW296.rup Calc=MJe Front Door laws: SE
- - wrightsoft- Project Summary Job:
Date: Dec 24, 2018
'Rest of -House) Ay:
For.
Notes:
MW-286
9431 MEADOWOOD DR, FORT PIERCE, FL 34951
Design
Weather: Vero Beach
Municipal AP, FL, US
Winter. Design Conditions
Summer Design Conditions
Outside db
43 OF
Outside db
91 OF
Inside db
70 OF
Inside db.
72 OF
Design TD
27 OF
Design TD
19 OF
Daily range
L
Relative humidity
50 %
Moisture difference
65 grfib
Heating Summary
Sensible Cooling Equipment Load Sizing
Structure
23210 Btuh
Structure
30552 Btuh
Ducts
4403 Btuh
Ducts
5329 Btuh
Central vent (0 cfm)
0 Btuh
Central vent (0 cfm)
0 Btuh
Humidification
0 Btuh
Blower
0 Btuh
Piping:
0 Btuh
Equipment load
27613 Btuh
Use manufacturers data
n.
Infiltration
Rate/swing multiplier
Equipment sensible load
0.95
34362 Btuh
Method
Simplified
Latent Cooling Equipment Load Sizing
Construction quality
Average
Fireplaces
0
Structure
9078 Btuh
Ducts
2080 Btuh
Heating Cooling
Central vent (0 cfm)
0 Btuh
Area
2079 2079
Equipment latent load
11158 Btuh
e
Volume ((t')
23229 23229
Air changes/hour
0.25 0.13
Equipment total load
45520 Btuh
Equiv. AVF (cfm).
98 49
Req. total capacity at 0.70 SHR
4.1 ton
Heating Equipment
Summary
Cooling Equipment Summary
Make
Make Carrier
Trade
Trade 16 SEER PURON AC
Model
Cond CA16NA048""A
AHRI ref
Coil FV4CNB006
AHRI ref , 4585139
Efficiency
100 EFF
Efficiency 14.0 EER, 96 SEER
Heating Input
8.2 kW
Sensible cooling
32550 Btuh
Heating output
27866 Btuh
Latent cooling
13950 Btuh
Temperature rise
16 OF
Total cooling
46500 Btuh
Actual air flow
1550 cfm
Actual air flow
1550 cfm
Air flow factor
0.056 cfmlBtuh
Air flow factor
0.043 cfm/Btuh
Static pressure
0 in H2O
Static pressure
0 in H2O
Space thermostat
Load sensible heat ratio
0.76
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
WrigtlkSofL'
RIghISulle4l Unlverse1201212.1.05 RSU02818
2018•Coo27 C8:34A4
C:Nser6UesonlDowmenis\Wdghisoll HVACU7W.288.rvp Calc=MJB Front Cbor faces: BE
Page 1 '
- wrightsoft• Project Summary
For: MW-286
9431 MEADOWOOD DR, FORT PIERCE, FL 34951
Notes:
Job:
Data: Dec 24, 2018
Design Information
Weather. Vero Beach Municipal AP, FL, US
Winter Design
Conditions
Summer Design Conditions
Outside db .
43
OF
Outside db
91
of
Inside db
70
OF
Inside db
72
OF
Design TD
27
OF
Design TO
19
OF
Daily range
L
Relative humidity
50
%
Moisture difference
65
grAb
Heating Summary
Sensible Cooling Equipment
Load Sizing
Structure
13262
Btuh
Structure
11574
Btuh
Ducts
1340
Btuh
Ducts
1676
Btuh
Central vent (0 cfm)
0
Btuh
Central vent (0 cfm)
0
Btuh
Humidification
0
Btuh
Blower
0
Btuh
Piping
0
Btuh
Equipment load
14602
Btuh
Use manufacturer's data
n
Rate/swing multiplier
0.95
Infiltration
Equipment sensible load
12654
Btuh
Method
Simplified
Latent Cooling Equipment Load Sizing
ConsWction quality
Average
Fireplaces
0
Structure
4336
Btuh
Ducts
711
Btuh
Heating
Cooling
Central vent (0 cfm)
0
Btuh
Area (ft')
908
908
Equipment latent load
5048
Btuh
Volume (its)
9114
9114
Airchanges/hour,
0.49
0.24
Equipment total load
17701
Btuh
Equiv. AVF (cfm)
74
37
Req. total capacity at 0.70 SHR
1.5
ton _
Heating Equipment Summary
Cooling Equipment
Summary
Make
Make Carrier
Trade
Trade 16-SEER PURON AC
Model
Cond CA16NA018""A
AHRI ref
Coil FV4CNF002
AHRI ref 4583820
Efficiency
100
EFF
Efficiency 14.0 EER,
16 SEER
Heating Input
4.3
kW
Sensible cooling
13510
Btuh
Heating output
14592
Btuh
Latent cooling
5790
Btuh
Temperature rise
21
OF
Total cooling
19300
Btuh
Actual air flow
643
cfm
Actual air flow
643
cfm
Air flow factor
0.044
cfm/Btuh
Air flow factor
0.049
cfm/Btuh
Static pressure
0
in H2O
Static pressure
0
in H2O
Space thermostat
Load sensible heat ratio
0.72
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
Cy " Wrightsoft6. RlghtSuileO Universal 201212.1.05 RSU02816 2D18-Dao-27 0e:34:44
Calc=MJB Front Door laces: BPage 2
'C1UaenUesonlDowmenls\WrlghtsoR HVACIMW-288.mp E
81
39
2a
® LL
GHO HOMES
MW-286
9451 MEADOWOOD DR
FORT PIERCE, FL 54951