Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
GAS PAPERWORK
G N H mF§ U I m U O j 3232 SE. Dixie Hwy. Stuart, FL 34007 Office 772-287.4330 Fox 772-287.3460 Chris & Vanessa Gumm 12314 Harbour Ridge Blvd FLORIDA ZIP 34990 191YI&IN ELLGAS BY E: 772-287-4330 LATION TO BE MADE IN OCCORDANCE WITH 4 & 68 AS WELL AS ALL STATE AND CODES TS 1 BTU'S 100,000 STAGE LV3403TR MEC STAGE LV4031366 MEC (SIZE 57 xx APPLIANCE INSIDE BUILDING ENVELOPE, UG LINE 10 PSI/ INTERIOR 12" TO 13" WC Z' 10 i w o Z �4 y ZQ r"i Qca• ® �a.9 oa wui LU Uw U o J O m 0 `0 G m¢ 20 `a 00 jgu WW Val U m O 2 O JCc aZ y W W Z O 1 ca z!1&Nz zE ag2i 1pp�000 "�TJ Ferrellgas ALL WORK SHALL BE IN ACCORDANCE WITH PROPANE TANK WIND LOAD _ NFPA-54-58; NATIONAL -FUEL: -GAS -CODE— FORCE ON TANK = 0.00256V'•A•Cd AND FLORIDA FUEL GAS CODE 2017 & = FLORIDA BUILDING CODE 2017. 0.00256(170mph)z • 6.66ft' 1.2 = 591 LBS TORQUE = 591 x 1.665 FT = 984 FT*LBS TANKS INSTALLED IN TRAFFIC AREAS SHALL BE PROTECTED WITH GALV. STEEL FORCE ON r CABLE = (492 / 1.67) = 295 LBS SCHED. 80 PIPE BOLLARDS (470) 6' LONG TENSILE STRENGTH OF d CABLE = 2OD0 LBS X 3' BURY DEPTH WITH CAP ® 3' O.C. FORCE ON AUGER ANCHOR = 295 LBS MIN. PULL-OUT RESISTANCE OF AUGER ANCHOR = 1360 LBS WIND LOAD CERTIFICATION: CODE FBC 2017 / ASCE 7-10 WIND SPEED = 170 MPH, 3 SEC. GUST EXPOSURE D INTERNAL PRESSURE COEFF. 0.00 30 IN. x 30 IN. x 6 CONCRETE SLAB, 3,000 1 ® 28 DA 72 1. AIRCRAFT CABLE THRU BOTH CAIN LT Y GAUGER ANCHOR, 48' LONG W/ 6.0 HELIX SIDE ELEVATION 2 TOTAL SCALE V-' - 1'-0' 113 STRAPPING BOLT W/ AUGER ANCHOR BELOW 749 GALV. ,CRAFT CABLE FLAN VIEW SCALE V1' - 1'-0' 3232 SE Dixie Hwy. Stuart, FL 34997 DRAWN: APPROVED: DRAWING NUMBERI T-1 LP57AGS CONTAINERS LEG General Specifications Conforms to the latest edition of the ASME code for Pressure Vessels, Section All, Division 1. Complies with NFPA 58. Rated at 250 psig from -20" F. to 125" F. All tanks may be evacuated to a full (14.7 psi) vacuum. Vessel Finish: Coated with epoxy red powder. ( Tanks coated with the epoxy powder must be buried). For Aboveground use, tanks may be coated with TGIC powder. Applicable federal, state or local regulations may contain specific requirements for protective coatings and cathodic protection. The purchaser and installer are responsible for compliance with all federal, state or local regulations. �--� WITHDRAWAL vALVE FLOAT /- w \� ANODE GAUGE ® X CONNECTION O bO' VALVE SERVICE/ NAME MULTIVALVE PLATE RELIEF VALVE FITTINGS LAYOUT UNDER DOME AGUG VESSEL DIMENSIONAL INFORMATION All vessels dimensions are appropmate WATER OUTSIDE HEAD OVERALL OVERALL LEG LEG WEIGHT QUANTITY FULL PER CAPACITY DIAMETER TYPE LENGTH HEIGHT WIDTH SPACING LOAD STACK 120 wg. 24", Ellip 5' - 5 13/16" 3' - 0" 10 118" 3' - 0" 245 lbs. 96 12 454.2 L 609.6 mm 1671.3mm 91 l A mm 257.2 mm 914A mm 111.1 kg. 250 wg. 31.5" Hemi T- 2 1/2" T - 7 1/2" 12 3/4" T - 6" 4721bs. 63 9 946.3 L 800.1 mm 2197.1 mm 1104.9 mm 323.9 mm 1066.8 mm 1 214.1 kg. 320 wg. 31.5" Hemi 8' -11 314" 3' - 7 1/2" 12 314" 4' - 0 114" 588 lbs. 45 9 1211.2 L 800.1 mm 2736.9 mm 1104.9 mm 323.9 mm 1225.6 mm 266.7 kg. 500 wg. 37.42" Hemi 9' -10" 4' -1 7/16" 15" 5' - 0" 871 lbs. 30 6 1892.5 L 950.5 mm 2997.2 mm 1255.7 mm 381.0 mm 1524.0 mm 395.1 kg 1000 wg. 40.96" Hemi 15' -10 13/16" 4' - 4 6116' 16 114" V.0. 1729 lbs. 15 5 3785.0 L 1040A mm 4846.6 mm 1344.6 mm 412.8 mm 2743.2 mm 784.3 kg Rev: Jw.27.20% First Stage Regulators, High Pressure, Domestic Provides accurate first stage regulation in two -stage bulk tank systems. Reduces tank pressure to an Intermediate pressure of 5 to 10 PSIG. Also used to supply high pressure burners for applications like industrial furnaces or boilers. Domestic LP -gas installations, also incorporated in multiple cylinder installations. PART NUMBER INLET CONNECTION OUTLET CONNECTION ORIFICE SIZE FACTORY DELIVERED PRESSURE INTEGRALRELIEF ADJUSTMENT RANGE VALVE INCLUDED VAPOR CAPACITY BTU/HR. PROPANE LV3403TR • ' • 1/4" F. NPT 1/2' ENPT ..1/4 • '11, `. ", 9=13 Yes- 1,500,000 LV4403TR4 112" F. NPT 1/2" F. NPT 1/4" 10 5-10 Yes 2,500,000- LV4403SR9 1127RNPT" -1127F.'NPT 1/40 5_ ";1-5 .'_Yes: .' 4500,000'-' LV4403TR9 F POL 1/2" F. NPT 1/4' 10 5-10 Yes 2,500,000- LV4403SR96 I ` F.'POL 3/4".F.NPT 4° 1°, "5 :..5�1--15D Yes... 25001000' F. POL 314"NPT114 F 1LV4403TR96 0 Yes 2,500,000" 15403TRVII 1 1/,4"'F. NPT . 1/27 F. NPT 1 1/4° r. 10' : ' Yes , '. " '1;500,000"'. Maximum flow based on inlet pressure 20 PSIG higher than the re0ulatar setting and delivery pressure 20% lowerthan the setting. •• Vent at 9 *Wck. Reg®Low Pressure Second Stage Regulators:' Second Stage Regulators low Pressure, Domestic 9LVSSO Designed to reduce first stage pressure of 5 to 20 PSIG down to burner pressure, normally 1r WC. Ideal for medium commercial installations, multiple cylinder Installations and normal domestic loads.Backmount Design Mounts directly to house line piping. Eliminates need for union joints and elbows and a LV4403B38 mounting brackets. Quick and easy to install. PARTNUMBER INLET CONNECTION OUTLET CONNECTION ORIFICE SIZE FACTORY DELIVERED PRESSURE ADJUSTMENT RANGE VENT POSITION VAPOR CAPACITY BTU/HR. PROPANE 1V4403114 i/2" F NPT, i 1/2" F. NPT" 7#28 Drill it"- WC at 10 PSIG Inlet . 9" to 13" WC _ Over Inlet _ - - 935,000 - ` LV4403B46 1/2" F. NPT 3/4"F. NPT F28 Drill 11" WC at 10 PSIG Inlet 9" to 13" WC Overinlet 935,000 LV4403B46R' 1/2"F.'NPT '3/4"F.NPT 028Drill 110 WC it 10,PSIG Inlet 9"to13"WC 'Overinlet 935,000'. LV4403866 3/4" F. NPT 3/4" F. NPT 428 Drill 11" WC at 10 PSIG Inlet 9" to 13" WC Over Inlet 935,000 LV4403B66W'.. ' 3/4" F. NPT 3/4" F. NPT, 928 Drill 11"WC at 10 PSIG Inlet 9" to 13° WC Over Inlet 935,000' LV5503B4 1/2" F. NPT 3/4" F NPT 1/4" 11" WC at 10 PSIG Inlet 9" to 13" WC Overinlet 1,600,000 LV5503B6 3/4'F.NPT 3/4"F.NPT, :, 114" 11"WC at10,PSIG:Inlet 9"to13"We Over lnlat 4,600,000 LV5503BB 3/4" F. NPT 1" F. NPT 9132" 11"WC at 10 PSIG Inlet 9" to 13" WC Overinlet 2,300,000 LV4403866RA** 3/4" F. NPT 314" F. NPT 3116" 11" WCat10 PSIG Inlet .9" to 13" WC..:Overinlet 1,000,000 LV4403B66R- AB" 3/4" F. NPT 3/4" F. NPT 3116" 11" WC at 10 PSIG Inlet 9" to 13" WC Over Inlet 1,000,000 LV3403B4 . ' 1/2' F NPT . 1/2" E NPT - 1/4" 11" WC at 10 PSIG Inlet • Backmount Design "" Sidemount Design Rego Low Pressure Second Stage Tobacco Barri Regulator Especially developed for drying barns in the tobacco industry. The LV5503G4 regulator will supply a steady and constant flow of fuel to as many as 12 to 20 burners throughout the barn. x LV550IG4 YL PART NUMBER INLET CONNECTION OUTLET CONNECTION ORIFICE SIZE FACTORY DELIVERED PRESSURE ADJUSTMENT RANGE VENT POSITION VAPOR CAPACITY BTU/ HR. PROPANE LV5503G4 112" F. NPT 3/4" F NPT 114" 15" WC at 15 PSI iblet 8"48" WC Overtolet 1,750,000 ' *Maximum flow is based on 15 PSIG inlet and 13" WC delivery pressure. 1 5844 UQU PIED PETROLEUM GAS CODE Table 15.l(0) Polyethylene Plastic Pipe Sizing Between First -Stage and Second -Stage Regulators: Nominal Outside Diameter (IPS) Gas: Undiluted Propane Inlet Pressure.- 10.0 psi Pressure Drop: 1.0 psi Specific Gravity: 1.52 Plastic Pipe tfs in. a/4 in. 1 in. 1t/4 in. Ith in. 2 in. Length SDR 9.33 SDR 13A SDR 11.00 SDR I0.00 SDR II.00 SDR 11.00 (Yt) (0.660) (0.860) (1.077) (1.328) (1.554) (1.943) 30 2143 4292 7744 13416 20260 36402 40 1835 3673 6628 11482 17340 31155 50 1626 3256 5874 10176 15368 27612 60 1473 2950 5322 9220 13924 25019 70 1355 2714 4895 8483 12810 23017 80 1261 2525 4555 7891 11918 21413 90 1183 2369 4274 7404 11182 20091 100 1117 2238 4037 6994 10562 18978 125 990 1983 3578 6199 9361 16820 150 897 1797 3242 5616 8482 15240 175 826 1653 2983 5167 7803 14020 200 778 1539 2775 4807 7259 13043 225 721 1443 2603 4510 6811 12238 250 681 1363 2459 4260 6434 11560 275 646 1294 2336 4046 6111 10979 300 617 1235 2228 3860 5830 10474 350 567 1136 2050 3551 5363 9636 400 528 1057 1907 3304 4989 8965 450 495 992 1789 3100 4681 8411 500 468 937 1690 2928 4422 7945 600 424 849 1531 2653 4007 7199 700 390 781 1409 2441 3686 6623 800 363 726 1311 2271 3429 6161 900 340 682 1230 2131 3217 5781 1000 322 644 1162 2012 3039 5461 1500 258 517 933 1616 2441 4885 2000 221 443 798 1383 2089 3753 IPS: Iron pipe sue. SDR• Standard dimension ratio. Notes: (1) Capacities are in 1000 Btu/hr. (2) Dimensions in parentheses are inside diameter 2011 Efton NATIONAL FUEL GAS CODE ANSI Z223.1-48 Table 6.3 (d) Schedule 40 ➢ietamc Pipe Gac Undiluted 2ropaoe 1Ne1I'tcmec II.O m.wL Presmm Drop: DSin.w.c Specific Gravrtp. 3S0 :a: .: r}�t�yY�".'..f�,Gy%i:S�y ^.i.{ry�" +�,l�, ~a�.ti.FJi•�it'clr^+' IDV�1�]nl!:��i.. - .:.i....�'_ n%. 9i ..fs ' 2PtpG Sire Y'�1 Nem nal Iosidc % N 1 IV,lYa Y 299 S 4 Act%=L 0.622 0.824 1.N9 Id80 1.610 2.067 2A69 3.068 4.026 length (4V Capacty io Thotuaods o1 Bw perFioer 30 291 608 1.150 2.550 3520 6.790 10,800 19,100 39,000 20 2DO 418 767 1,620 2,420 4.660 7,4N 13,100 26,600 30 360 336 639 ]AM 1,940 3.750 5.970 20,600 21,500 40 197 287 511 '%]10 1,660 3,210 6.110 2,030 18.400 50 122 255 480 985 1.486 Z840 4530 B4O00 36— O 60 110 231 434 992 1590 2570 4,700 7250 IOOD 6D 201 212 400 821 Lm 2.370 3,770 6,570 1S500 100 94 197 972. 763 1,140 2200 3510 6,210 ]ZI00 125 69 185 S49 716 1.070 2.070 3290 5,820 11,900 150 84 175 530 677 IA30 1.950 3,110 5500 II= 175 74 155 292 600 899 1,750 2.760 4.660 9.950 20D 67 140 265 543 814 1,570 2Z00 4,m 9,010 250 62 124 243 500 749 1,440 2500 4.06D 8290 300 58 120 227 465 697 1,340 2,14D 3.781 7,720 350 51 307 201 412 SIB 1.190 1,900 3550 6,840 400 46 97 182 373 560 I.O80 1.720 3,040 6.190 450 42 89 167 314 515 991 11580 Z790 5.700 Soo 40 83 156 320 479 922 1,470 2500 51300 550 37 78 146 900 449 865 1580 2,440 4570 600 35 73 138 283 1 424 817 1 ISDO 2,30D 4,700 650 35 70 IN 269 403 776 1240 2.190 4.460 700 32 66 125 257 385 141 1.180 2,M 4260 750 30 64 120 246 968 709 law 2" 4,OB0 8DO 29 61 115 236 354 681 1,090 1,920 3,920 850 28 59 111 227 .341 656 1,050 1,860 3,770 900 27 57 107 220 929 634 1.010 1,79D 3,640 950 26 55 104 213 •319 613 978 1.730 3530 1.000 25 53 100 206 309 595 90 1560 3,420 1.100 25 52 97 200 S00 578 921 1" SAW 1.200 24 50 95 1 195 292 562 695 1560 SA30 I'm 23 48 90 195 277 634 850 150D 3,070 1.400 22 46 86 176 264 509 811 1,430 2930 ISOo 21 44 82 169 25S 487 777 1570 2.800 1.600 20 42 79 162 243 468 746 I'm 2.690 1,700 19 40 76 156 234 1 451 719 1270 2540 1.800 19 39 74 151 226 436 694 1.230 2,500 I'm16 38 71 146 219 422 672 1.19D 2,420 2,000 18 37 69 142 212 409 652 1.150 2550 Now A0 table maim are mtmded m 3 slg0i6tantdigio. 58-88 LIQUEFIED FEfROLEUM OAS CODE Between First -Stage and OutvdeDiameter Copper Tubing, Go= Undiluted . Propane. luletpressure- IO.Opsi Pressure Drop: 1.0 psi pemfic Gravity 152 length ai§in. %in. %in. 4L& %i0 (ft) 0.305 '0.402 0.527 16.659, '6:745' 30 284 587 1193 2085 2959 40 243 502 1021 1785 2532 50 236 445. 905 1582 2244 60 -.195 403 826 1433 2033 76 180 371 754 1319 1871 80 167 345 702 1927• 1740 40 157. 374 650 1151 1633 100 148 305 Ql2 3087 1542' 150 119 246 500 813 1239 200 102 210 428 747 1060 250 90 186 379 662 940 300 82 169 343 600 851 350 75 155 316 552 783 460' 70 144 2N 514 129 450 66 156 276' 482 654' 500 62 .128 260 455 646 600 56 116 236 412 585 700 52 107 217 379 538 800 48 99 202 353 501 900 45 93 189 331 470 1000 43 88 179 313 444 1500 34 71 144 251 356 2000 29 60 123 215 305. Notes: (1) Capacities am in 100,0 Btu/hr. (2) To convert to capacities at a gauge pressure of 5 psi setting with 10 percent (0.5 psi) pressure drop, multiply values by 0.606. To con- vert to npaddes at a gauge pressure of 15 psi settingwith 10 percent (15 psi) pressure drop, multiply values by 1.380. Table15.1(g) :Copper Tub tSBetween Second-St9ge Regulator rand'ApplianceusideDiameterCopperTubing, Type 1 Inlet ]?ressaae: I -I I in. wk. r . 3fi m. yi ha. ' . %IM Id. '%in. (fty 0.305 OA02 0.527 0.652 0.745 10. 45 93 188 329 .467 ,20 31 64 129 226 321 30 25 51 104 182 258 40 21 44 89 156 221 50 19 39 79 138 •196 .60 17 35' 71 125 177 80 15 30 61 167 In 100 13 27 54 95 134 125 11 24 49 84, 119.' 150 10 21 ' 44 76 10' .200• 9 18 37 65 92 250 8 16 33 58 82 306 7 I5 30 52 74 350 7 14 28 48 68 460 6 13 26 45 63 Now Capacities are in 1000 Btu/hr. !t. �VDv-. �c Master Bedroom I614 ° x 1310" Living Room 19'4' x 15'0 u Dining Area 1318' x 1314 " x 10'0' Den/Guest Bedroom 1210' x 10'0' 0v v7 inn WIN 1,Bedroom in , - 10=7' W111111 Two Car Garage 20'0' x 2010' t•