Loading...
HomeMy WebLinkAboutPRODUCT APPROVALxrrc Hortce U01 In i User Rtpistraaon Hat Topic Subml[SurNarge i Statsa Fans , Publicaaons WSWff i WISSie Hap Unk SearN db=,Ct Approval P b c User ProdUm a I n > Product or AyolicaEon stamp > H_pPlicaben ea >.Appiiudon Detail FL R Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Emall Category Subcategory Compliance Method FL17443-RI Revision 2017 Approved I A TAYLOR ROOFING 302 Melton Drive FT PIERCE, FL 34982 (772)466-4040 kylewhite228@aoi.com Kyle Taylor kylewhite228@aol. com Roofing Metal Roofing SCANNED BY St. Lucie County Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ' Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Locke Bowden Evaluation Report Florida License PE-49704 Quality Assurance Entity PRI Construction Materials Technologies, LLC Quality Assurance Contract Expiration Date 01/23/2023 Validated By Zachary R. Priest, P.E. " Validation Checklist - Hardcopy Received Certificate of Independence il6re:x�• . � .. Referenced Standard and Year (of Standard) Standard TAB 125 UL 1897 UL580 Equivalence of Product Standards Certified By Sections from the Code Year 2003 2012 2006 F 'L Py _ —Product ApprovalMethod- Method 1-OptionD N Date Submitted 01/24/2018 Date Validated 02/14/2018 Date Pending FBC Approval 02/17/2018 Date Approved 04/10/2018 SummaN of Products FL A Model, Number or Name Description 117443.1 5 V Comp 26GA 1/2" rib height over 15/32" APA plywood Limits of Use Installation Instructions Approved for use In HVHZ: No FL17443 RI II FL 17443 3 A Taylor 2017 Code Eval Reporti with Details RSSS.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/-129.25 Created by Independent Third Party: Yes Other:-129.25 @ 6" o.c. -69.25 @16" o.c. margin of safety Evaluation Reports 2:1 with 24" max. coverage Install per manufacturers detail. FL17443 RI AE FL 17443 J A Taylor 2017 Code Eva1 Regg11 with Details RSSS.pdf Not for use in HVHZ Created by Independent Third Party: Yes �J 117443.2 VICTORIAN CRIMP SHINGLE 26GA 2/2" RIB- PANELS LOCK INTO PREVIOUS PANELS; OVER CDX/APA 15/32 PLYWOOD Limits of Use Installation Instructions Approved for use In HVHZ: No FLI7443 RI 11 FL 17443 J A Taylor 2017 QIg Eval Re p-Q(5 Approved for use outside HVHZ: Yes with Details RSSS.p-df Impact Resistant: N/A Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/-105 Created by Independent Third Party: Yes Other:-105PSF margin of safety 2:1. Install per I Evaluation Reports manufacturer's details and in compliance with FBC 2017 6th FL17443 R1 AE FL 17443 J q Taylor 2017 Code Eval Report with Details RSSS.pdf Created by Independent Third Party: Yes _- _ __ 4 ed. Not for use in HVHZ. Bask rveea contact es ;: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 850.487-1824 The Stale of Florida Is an AAJEEO employer. copyright 2007-2013 State of Florida.:: Privaa Statement :: Q{(q«ibllity Statement :: Refund Statement Under Florida law, email addresses are public records, If you do not want your c-mail address released in response to a public -records request, do not send electrunic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.4117.1395, !Pursuant to section 455,275(1), Florida statuses, eneCive October 1, 2012, licensees licensed under chapter 455, F.S. must provide the Department w.th an email address it they, have one. The emaUs pmWded may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a hoemse under chapter 455, F.S., please dick here. Produce Approval Accepts: ® ® ® El En 'f f SCCII YIT\`Tt NTIi I L"ti BCIS Home Log In User eepistrat" Hot Teplcs 5u0me 5410w190 Slats a FsCS 101,18e005 Contact Us aCIS Sep Map bnks Y 5earce dbplr Z t Product pproval USeR: zteAUsera Product Rgimmal Mme> pLggus AAiy+l_4ilSY^ LJt> Application Oebll FL S FL1654-R23 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer POLYGLASS USA Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach,, FL 33442 (954) 233-1330. Ext 242 malpert@polygtass.com Authorized Signature Maury Alpert malpert@polyglass.com Technical Representative Maury Alpert Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach,. FL 33442 (912)429-6610 MAlp ert@ polyglass.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Modified Bitumen Roof System S�A�/VFD St Lucie County Compliance Method Evaluation Report from a. Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - HarelcopyReceived Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance. Contract Expiration Date 09/13/2021 Validated By John W. Knezevich, PE `+ Validation Checklist - Hardcopy Received Certificate of independence Referenced Standard and Year (of Standard) F 1654 R23 COI 2018 01 CQJ NI MI€ Rdf ASTM 161 � e ASTM D6163 ���iii 008 ASTM D6164 2011 ASTM D6222 2011 ASTM D6509 2009 FM 4470 2012 FM 4474 2011 UL 1897 2012 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method. Date Submitted Date Validated Date Pending FBC Approval Date Approved FL V 1654.1 Model, Number or Name Polyglass SBS and APP Modified Bitumen Roof Systems Limps of Use Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/.622.5 Other: 1.) The design pressure in this application relates to one particular assembly over concrete deck. Refer to the ER Appendix for other systems and deck types. 2.) Refer to ER, Section 5 for other Limits of Method 1 Option D 10/08/2018 10/13/2018 10/21/2018 12/11/2018 Description- SBS and APP modified bitumen roof systems Installation Instructions FL1654 R23 11 2018 10 PfNAI Al ER POIYGIASS.. MOD IT FL.1654 R23.kdf i Verified By: Robert Nieminen PE-59166. Created by Independent Third Party: Yes Evaluation Reports FL1654 R23 AE 2018 10 FINAL ER POVeCLASS MODB1T FL1654- Created by Independent Third Party: Yes o l!att Us 8 2601 Era Seor4 Road Talfanasse , P_ 32399 onme: 650-487-1924 The state Of FlDrida rs an ANFSO, emdl0y&.. COoinmot 2001d013 gate of FlOnda.:: Rnvacv sFeament ::.4aesziYaty $Lrtemen! : r Refund Statement Under Honda law, email addresses are public RCO . It yen do not Want your e-muH addmsS misused In FCSpor sO t0 a pu' FC- Ords rec uest, do net send eleehh m, mail W this "on. instead, Dontact the offineby phone of by traddional mad. If you no. any questions, please comatt SM.437.1395. 'Pursuant to Seddon 45S.275(T), FlOrtia statutes, eeeCOve Wooer 1, 2012, fcenume, licensed Under chapter 455, F.S. must provide me Department Witb an email address if they have one. The emeAS provided may be used for offidal comm@uCation with the ptensee. However emet addresses are Pubk record. If you do not wish to supply a pmsOnal address, please provide the Department With an email address whUd, ran be made available W the pubrx. TO dMermine, If you are a ficensee under chapter 455, RS., please chm hero. product ApPrpval Adepts: IMW71 F99H 0 Credit Card Safe ONEMOjex'c. APPENDIX 1: TABLE ATTACHMENT REQUIREMENTS R WIND DECK • UPLIFT RESISTANCE APPLICATION TYPE DESCRIPTION _, - PAGE' 3A Wood New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 1 5 1B Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5-9 1C Wood New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 10�11 1D Woad New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 12 1E Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 12f14 1F Wood New, Reroof (Tear -Off) or Recover D Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 15.17 1G Wood New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover 18-21 1H Wood New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet (screws 8, plates), Bonded Roof Cover 21.25 11 Wood New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover ;26 2A Steel or Structural concrete New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 27-29 2B Steel or Structural concrete New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 30;34 2C Steel or Structural concrete New, Reroof (Tear -Off) or Recover D Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 35�37 3A Structural concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 38-46 3B Structural concrete New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 146 4A Lightweight concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 47=.49 4B Lightweight concrete New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 150 4C Lightweight concrete New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 51153 SA Cementitious wood fiber New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 154 SB Cementitious wood fiber New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 55 Sc Cementitious wood fiber New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 156 SO Cementitious wood fiber New, Reroof (Tear -Off) or Recover C Mach. Attached Insulation, Banded Roof Cover 156 SE Cementitious wood fiber New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 56 6A Existing gypsum Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 57-59 6B Existing gypsum Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 159 6C Existing gypsum Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 60 6D Existing gypsum Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover '60 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 61-65 7B Various Recover F Non -Insulated, Bonded Base Sheet, Bonded Roof Cover 65 The following notes aooly to the systems outlined herein: 1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdlctlon. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement: ➢Wood: Minimum 0.75-inch penetration. - DSteel: Minimum 0.75-Inch penetration and engagethetop flute ofthe steel deck. ➢ Structural concrete: Minimum 1-Inch embedment Into pilot hole in accordance with fastener manufacturer's published Installation instructions. NEMO ETC, LLC Evaluation Report P9290.02.08-R21 for FL1654-R23 Certificate of Authorization #32455 ST" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 10/08/2018 Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 1 of 65 I NNEMO etc. 3. Unless otherwise noted, Insulation maybe anyone layer or combination of polyisocyanurate,polystyrene, wood fiberboard, perlite,gypsum-based roof board or mineral -wool roof board that meets the QA requlrei ents of F.A.C. Rule 61G2G-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. 4. Minimum 200 psi, minimum 2-inch thick lightweight Insulating concrete maybe substituted for rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base! sheet fasteners are Installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. I S. Preliminary Insulation attachment for System Type D: Unless otherwise noted, referto Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016). 6. Unless otherwise noted, Insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted In the manufacturer's published Instructions. D Hot asphalt (HA): Full coverage at 25-30lbs/square. D Dow INSTA STIK Quik Set Insulation Adhesive (D-I5): Continuous 0.75 to 1-Inch wide ribbons, 12-Inch o.c. D Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-Inch wide ribbons,12-Inch o.c. D Millennium PG-1 Pump Grade Adhesive (M-PG3): Continuous 0.25 to 0.5-Inch wide ribbons,12-Inch o.c. ➢ OMG OlyBond 500 (OB500): Continuous 0.75 to 1-Inch wide ribbons, 12-Inch o.c. (PaceCart or SpotShot). Note: OlyBond Green may be used where 01yBond500 Is referenced. ➢ OlyBond Classic (OB Classic): Full coverage at 1 gal/square. D ICP Adhesive & Sealants Polyset CR-20: Continuous 2.5-3.5-Inch wide ribbons,12-Inch o.c. ➢ Note: When multiple layers(s) of insulation and/or coverboard are Installed in ribbon-appiled adhesive, board joints shall be staggered. D Note: The maximum edge distance from the adhesive ribbon to the edge of the Insulation board shall be not less than one-half the specified ribbons spacing. 7. Unless otherwise noted, all Insulations are flat -stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations maybe substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to 'Increase' the MDP listings in the tables; rather If MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop -in for the equivalent thicker material listed In the table: ➢ Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psf (Min. 0.5-Inch thick) ➢ Millennium PG-1 Pump Grade Adhesive (M-PG3): MDP -157.5 psf (Min. 0.5-Inch thick) ➢ OMG OlyBond 500 (OB500): MDP -45.0 psf (Min. 0.5-Inch thick Multi -Max FA-3) ➢ OMG OlyBond 500 (OB500): MDP -187.5 psf (Min. 0.5-Inch thick ISO 95+GL) D OMG OlyBond 500 (OB500): MDP -315.0 psf (Min. 0.5-Inch thick ENRGY 3) D OMG OlyBond 500 (OB500): MDP -487.5 psf (Min. 0.5-Inch thick ACFoam II) D ICP Adhesives & Sealants Polyset CR-20: MDP -117.5 psf (Min.1.0-Inch thick) 8. Bonded polyisocyanurate Insulation boards shall be maximum 4 x 4 ft. 9. For mechanically attached components or partially bonded Insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD3, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RA5117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk- carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention, Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 10. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined In accordance with FBC Chapter 16, and no rational analysis Is permitted. 11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be In accordance with ANSI/SPRI FX-1 or Testing Application Standard TA5105. 12. For existing substrates In a bonded recover or re -roof Installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance'with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13. For Recover Applications using System Type D, the insulation Is optional; however, the existing roof system shall be suitable for a recover application. NEMO ETC, LLC Certificate of Authorization t132455 Prepared by: Robert Nleminen, PE-59166 6- EDITION (2017) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233.1330 Evaluation Report P9290.02.08-R21 for FL1654-R23 Revision 21: 10/08/2018 Appendix 1, Page 2 of 65 i ONEMID gtC. 14. Lightweight Insulating Concrete (LWC) shall be cast In accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWC Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat thickness is 2-inches. For LWC over structural concrete, reference Is made to FBC Section 1917.4.1, Point 1. For "pre-existent' LWC references, listings were established through testing over lightweight concrete cast using only foaming agent (ASTM C896), water and Portland cement (ASTM C150), with no proprietary additives, in accordance with procedures adopted by Miami -Dade BCCO (FBC CER1592). Unless otherwise noted, use of these listings In new construction or re -roof (tear -off) applications Is at the discretion of the Designer or Record and Authority Having Jurisdiction. 15. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications. ROOF COVERS REFERENCE - LAYER MATERIAL. APPLICATION I. BP -AA Base Ply One or more plies Polyglass G2 Base, FBCApproved ASTM D4601, Type II (Base and Ply sheets, Ply One or more plies Polyglass Ply IV, Polyglass Ply VI, FBC Approved ASTM D2178, Type IV or VI Hot Asphalt at 20-40 Ibs/square Asphalt -Applied) Note: Asphalt-appliedsheets orinsulation shallnot be applied to poly -film surfaced membranes. Base Ply One ply Elastobase (sand/sand), Elastoflex V, Elastoflex 56, Elastoflex S6 Type 11, Polyglass HT Base 650 PG350 at 1.5-2.0 SBS-CA3 Cap Ply Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 Type II, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshield gal/square TS-G FR, Polyfresko G SB5 (sand -backed), Polyfresko G SBS FR (sand -backed) Base Ply One ply Elastobase (sand/sand), Elastoflex V, Elastoflex 56, Elastoflex 56 Type II polyplus 35 at 1.5-2.0 SBS-CA2 Cap Ply Elastoflex VG, Elastoflex VG FR, Elastoflex 56, Elastoflex S6 Type 11, Elastoflex S6 G, Elastoflex 56 G FR, Elastoshield TS-G, Elastoshield gal/square TS-G FR, Polyfresko G 5BS (sand -backed), Polyfresko G SBS FR (sand -backed) One or more plies Elastobase (sand/sand or poly/sand), Elastobase P (sand/sand or poly/sand), Elastoflex V, Elastoflex S6, Elastoflex Base Ply or Ply S6 Type 11, Polyglass HT Base 650 SBS-AA (SBS, Asphalt -Applied) Cap Ply Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex 56, Elastoflex 56 Type II, Elastoflex S6 G, Elastoflex 56 G FR, Elastoshield TS-G, Hot Asphalt at 20-40 16s/square Elastoshield TS-G FRI, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed) � Note: Asphalt -applied sheets or Insulation shall not be applied to polyjlim surfaced membranes. One or more plies Elastobase (sand/poly), Elastobase (poly/poly), Elastoflex V, Elastoflex 56, Elastoflex S6 Type 11, Polyglass HT Base SBS-TA Base Ply or Ply Torch (SBS, Torch -Applied) Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6Type 11, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS- -Applied Cap Ply G, Elastoshield TS-G FR, Polyfresko G SBS (poly -film backed), Polyfresko G SBS FR (poly -film backed) Base Ply One or more plies Elastoflex SA V Base, Elastoflex SA V FR Base, Elastoflex SA V Plus, Elastoflex SA V Plus FR SBS-SA Cap Ply Elastoflex SA P, Elastoflex SA P FR, Polyreflect Self (SBS, Self -Adhering) Note: Unless otherwise noted, permissible membrane substrates for SBS-SA are limited to the SBS-SA Base Ply options herein, -Adhering Elastobase (poly/sand) or Elastobase (poly/poly). APP-CAI Cap Ply Polyflex G FR PG350 at 1.5-2.0 Hal/square APP-TA Base Ply or Ply One or more plies Polyglass APP Base, Polyflex, Polybond Torch (APP, Torch -Applied) Cap Ply Polyflex, Polyflex G, Polyflex G FR, Polybond, Polybond G, Polyfresko G, Polyfresko G FR -Applied Cap Ply Polyflex SA P, Polyflex 5A P FR, Polyfresko G SA, Polykool APP-SA Note; Unless otherwise noted, permissible membrane substratesforAPPSA are limited to the SBS-SA Base Ply options herein, Self -Adhering (APP, Self -Adhering) Elastobase (poly/sand) or Elastobase (poly/poly). NEMO ETC, LLC Evaluation Report P9290.02.08-R21 for FL3654-RZ3 Certificate of Authorization k32455 5- EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 10/08/2018 Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 3 of 65 16. Vapor barrier options for use over structural concrete deck followed by adhered insulation carry the following Maximum Design Pressure (MDP) limitations. applies: I NEMO eltc. The lesser of the MDP listings below vs. those in Table 3A OPTION If - PRIMER VAPOR BARRIER O. DECK; VAPOR BARRIER INSULATION ADHESIVE I MOP (PSF) TYPE ATTACH VB-1. PG100 Elastoflex SA V Plus Self -Adhering Inta-Stik or CR-20, 12-Inch D.C. -60.0 VB-2. PGS00 Polyglass APT Base Torch -applied Inta-Stik or CR-20, 12-inch D.C. -75.0 VB-3. PGS00 Elastoflex SAP Self -Adhering Insta-Stik, 12-inch D.C. -75.0 VB-4. PG100 Elastoflex SAP Self -Adhering Millennium One Step Foamable Adhesive,l2-Inch o.c. -15715 VB-5. PG100 Elastoflex SAP Self -Adhering CR-20, 12-Inch o.c. -270:0 VB-6. PG100 Elastoflex SA V Base, Elastoflex SA V FR Base, Elastoflex SA V Plus, Elastoflex SA V Plus FR Self -Adhering Millennium One Step Foamable Adhesive, Millennium PG-1 Pump Grade I Adhesive, OlyBond 500 or CR-20, 12-Inch D.C. -290,0 1 17. The following surfacing may be applied to the Cap Ply without adverse effect on the system wind load performance. Refer to current Florida Product Approval for approved Polyglass and KM Coatings roof coatings for application limitations and a Roofing Materials Directory for fire ratings associated with coating usage. Option p SURFACING OPTIONS Surfacing Florida Product Approval SURF-1. PG300 Fibered Roof Coating FL10291 SURF-2. PG600 Non-Fibered Aluminum Roof Coating FL10291 SURF-3. PG650 Fibered Aluminum Roof Coating FL10291 SURF-4. PG700 High Quality Elastomeric Roof Coating FL10291 SURF-5. PG700Q5 (Quick Set) High Quality Elastomeric Roof Coating FL10291 SURF-6. PG800 Asphalt Emulsion Roof Coating FL10291 SURF-7. Polyplus 60 Premium Non-Fibered Aluminum Roof Coating FL10291 SURF-8. Polyplus 65 Premium Fibered Aluminum Roof Coating FL10291 SURF-9. Polybrite 70 Premium Grade Elastomeric Roof Coating FL10291 SURF-30. Polybrite 70QS (Quick Set) Premium Grade Elastomeric Roof Coating FL10291 SURF-11. Polybrite 71 HS FL10291 SURF-12. Polybrite 90 High Solids Silicone Roof Coating FL10291 SURF-13. Polybrite 95 Silicone Roof Coating FL10291 SURF-14. KM Acryl 15 FL27409 SURF-15. KM Acryl 15 CIS FL27409 SURF-16. KM Acryl 25 FL27409 SURF-17. KM Acryl 25 CIS FL27409 SURF-18. KM Acryl 40 HS FL27409 SURF-19. KM Acry'85 FLEE SURF-20. KM M250 FL27409 SURF-21. KM PStf220 FL27409 18. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. NEMO ETC, LLC Evaluation Report P9290.02.08-R21 for FL3654-R23 Certificate of Authorization R32455 5- EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 10/08/2018 Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 4 of 65 NNEMOje'tc. TABLE11: WOOD DECKS— NEW CONSTRUCTION oR REROOF (TEAR -OFF) SYSTEM TYPE F: . BONDED ROOF System e Deck (Note 1( m Primer Roof Cover (Note 15) i - ° I MDP (psF) .. -' loins Treatment Base Ply Piy. I WpPly No. -170 in. 15/32- None None SBS-SA (Optional)SB5-SA, SBS- SBS-SA, APP-SA, SBS- _90.0 — mch plywood TA, APP-TA TA, APP-TA W-171 Min. 15/32- (Optional) PG100 None Polyflex SA Base (Optional)APP-TA APP-TA -90.0 Inch plywood W172 Min. 15/32- pG100 None SBS-SA (Optional)SBS-SA, SBS- SOS -SA, APP-SA, SBS- -975 Inch plywood TA, APP-TA TA, APP-TA Min. 15/32- Plywood joints are covered with flinch wide strips of Elastoflex SA V Plus, rolled Into Elastoflex SA V Base or (Optional) SB5-SA, 5B5- SBS-SA, APP-SA, SBS- 97.5 W-173 Inch plywood (Optional) PG100 place to create continuous bond. Elastoflex SA V FR Base TA, APP-TA TA, APP-TA W174 Min. 15/32- POLYBRITE 745 None SBS-SA (Optional) SB5-SA, SB5- SBS-SA, APP-SA, SBS- -105.0 Inch plywood TA,APP-TA TA, APP-TA Min. 15/32- Plywoodjoints are covered with 4-Inch wide strips of Elastoflex SA V Plus, rolled into Elastoflex SA V Plus or (Optional)SBS-SA, 5B5- SBS-SA, APP-SA, SBS- W-175 inch plywood (Optional) PG100 place to create continuous bond. Elastoflex SA V Plus FR TA, APP-TA TA, APP-TA -135.0 W-176 Min. 15/32- (Optional) PG100 Plywood joints are covered with 4-inch wide strips of Elastoflex SAVPlus, rolled into polyflex SA ease (Optional)APT-TAAPP-TA -135.0 Inch plywood place to create continuous bond. NEMO ETC, LLC Evaluation Report P9290.02.08-R21 for FL1654-R23 Certificate of Authorization #32455 15" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 10/O8/2018 Prepared by: Robert Merriman, PE-59166 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 26 of 65