HomeMy WebLinkAboutEVALUATION REPORTCREEK
TECHNICAL SERVICES, LLC
EVALUATION REPORT
Manufacturer:
Manufacturing Plants:
BORAL ROOFING LLC
7575 Irvine Center Drive
Irvine, CA 92618
(800)669-8453
www.boralamedea.com
Lake Wales, FL
Okeechobee,FL
Certificate of Authorization No. 29824
17520 Edinburgh Dr
Tampa; FL33647
(813)480-3421
FLORIDA BUILDING CODE C EDITION
Quality Assurance: PRI Construction Materials Technologies (QUA9110)
SCOPE
Issued October 15, 2018
SCANNED
BY
St. Lucie County
Category:
Roofing
Subcategory:
Roofing Tiles
Code Sections:
1507.3.5, 1607.3.7, 1523.6.5, 1523.6.5.2, 1523.6.5.2.2, 1523.6.5.2.3
Properties:
Physical Properties, Attachment Requirements, Wind Driven Rain, Static Uplift
Resistance
REFERENCES
Entity
Report No.
Standard
Year
American Test Lab of South Florida Inc (TST3782)
RT0130.01-14
TAS 112
1995
ASTM C 1492
2003(2009)
American Test Lab of South Florida Inc (TST3782)
RT0426.01-14
TAS 112
1995
ASTM C 1492
2003(2009)
American Test Lab of South Florida Inc (TST3782)
RT0615.02-11
TAS 112
1995
ASTM C 1492
2003(2009)
American Test Lab of South Florida Inc (TST3782)
RT0615.03-11
TAS 112
1995
ASTM C 1492
2003(2009)
American Test Lab of South Florida Inc (TST3782)
RT0615.04-11
TAS 112
1995
ASTM C 1492
2003(2009)
American Test Lab of South Florida Inc (TST3782)
RT0617.02-16
TAS 112
1995
ASTM C 1492
2003(2009)
American Test Lab of South Florida Inc (TST3782)
RT0617.03-16
TAS 112
1995
ASTM C 1492
2003(2009)
American Test Lab of South Florida Inc (TST3782)
RT0617.04-16
TAS 112
1995
ASTM C 1492
2003(2009)
American Test Lab of South Florida Inc (TST3782)
RT0623.04-14
TAS 112
1995
ASTM C 1492
2003(2009)
American Test Lab of South Florida Inc (TST3782)
RT0624.04-14
TAS 112
1995
ASTM C 1492
2003(2009)
American Test Lab of South Florida Inc (TST3782)
RT0624.05-14
TAS 112
1995
ASTM C 1492
2003(2009)
American Test Lab of South Florida Inc (TST3782)
RT1210.02-16
TAS 112
1995
ASTM C 1492
2003(2009)
American Test Lab of South Florida Inc (TST3782)
RT1210.03-15
TAS 112
1995
ASTM C 1492
2003(2009)
Miami -Dade BCCO (CER1592)
14-0408.06
FBC (HVHZ)
2017
Miami -Dade BCCO (CER1592)
14-0416.12
FBC (HVHZ)
2017
Miami -Dade BCCO (CER1592)
15-0721.04
FBC (HVHZ)
2017
Miami -Dade BCCO (CER1592)
16-0112.07
FBC (HVHZ)
2017
Miami -Dade BCCO (CER1592)
16-0112.08
FBC (HVHZ)
2017
Miami -Dade BCCO (CER1592)
18-0509.15
FBC (HVHZ)
2017
Miami -Dade BCCO (CER1592)
18-0509.16
FBC (HVHZ)
2017
Miami -Dade BCCO (CER1592)
18-0509.17
FBC (HVHZ)
2017
Tile Roof Institute
Membership Confirmation
TAS 100
1995
TAS 101
1995
TAS 102 & 102(A)
1995
BOR18003
FL28328
Page 1 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
BOR
CREEK AL ROOFINGLLC
Concretee RoofRoof Tiles
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION
Bermuda (Okeechobee)
Profile/Description: ASTM C 1492, TAS 112 Type 3a, flat profile, interlocking, class III concrete roof tile
Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications
Dimensions: 16" x 10"
16'--j
Figure 1. Bermuda
BOR18003 FL28328 Page 2 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
Plantation (Okeechobee)
BORAL ROOFING LLC
Concrete Roof Tiles
Profile/Description: ASTM C 1492, TAS 112 Type 3a, flat profile, interlocking, class III concrete roof tile
Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications
Dimensions: 16-1/2" x 13"
Figure 2. Plantation
Saxony 900 Slate, Shake and Split Shake (Lake Wales)
Profile/Description: ASTM C 1492, TAS 112 Type 3a, flat profile, interlocking, class III concrete roof tile
Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications
Dimensions: 17" x 13" x 1-5/32" (Slate) or 1-9/32" (Shake and Split Shake)
NA L HOLES
UNDERLOCK
Figure 3. Saxony 900 Slate
513Y'(SIM)
COVERLOCK
BOR18003 FL28328 Page 3 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICEs, LLC
NAM HOLES
F
NAM HOLES
F.
Figure 4. Saxony 900 Shake
y Y
Figure 5. Saxony 900 Split Shake
BORAL ROOFING LLC
Concrete Roof Tiles
1.9/32" (SbaW
MAT)
BOR18003 FL28328 Page 4 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
I
CREEK BORAL• ROOFING LLC
Concrete Roof Tiles
TECHNICAL SERVICES, LLC
Estate "S" (Okeechobee)
Profile/Description: ASTM C 1492, TAS 112 Type 1 b, low profile, interlocking, class III concrete roof file
Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications
Dimensions: 16-1/2" x 13"
Nail Holes -T-----i
Figure 6. Estate
Villa 900 (Lake Wales)
Profile/Description: ASTM C 1492, TAS 112 Type 1 b, low profile, interlocking, class III concrete roof file
Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications
Dimensions: 17.0" x 13" x 2-118"
1'
If13"
Figure 7. Villa 900
2t/6"
BOR18003 r•Leaaza '
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall ni
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this re
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes
specifically addressed herein.
12
is valid.
are not
CREED
TECHNICAL SERVICES, LLC
Barcelona 900 (Lake Wales)
BORAL ROOFING LLC
Concrete Roof Tiles
Profile/Description: ASTM C 1492, TAS 112 Type 1 a, high profile, interlocking, class III, 'S' shaped concrete
roof file
Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications
Dimensions: 17" x 13" x 3-5/8"
iB"
z
Figure 8. Barcelona 900
Galena Spanish `rS" (Okeechobee)
Profile/Description: ASTM C 1492, TAS 112 Type 2a, high profile, interlocking, class III 'S' shaped concrete
roof tile
Allowable Applications: For mechanically fastened (direct deck), mortar set or adhesive set applications
Dimensions: 17" x 10" x 2.7"
Fastener Holes
17" 10"
Figure 9. Galena Spanish "Srr
BOR18003 FL28328 Page 6 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK BORAL ROOFING LLC
Concrete Roof Tiles
TECHNICAL SERVICES, LLC
Spanish "S" Nuevo (Lake Wales)
Profile/Description: ASTM C 1492, TAS 112 Type 2a, high profile, interlocking, class 111 'S' shaped concrete
roof tile
Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications
Dimensions: 17" x 9-3/4" x 2-27132"
Fastener
APPLICATION METHOD
Hales
17"
9-3/4"
Figure 10. Spanish "S" Nuevo
Installation
Limited to slopes 3:12 or greater in the HVHZ; Outside the HVHZ, shall be in accordance
Slope:
with the recommendations of the FRSA/TRI Florida High Wind Concrete and Clay Roof
Tile Installation Manual, Fifth Edition Revised or RAS 118, RAS 119, or RAS 120, as
applicable.
Solid or closely fitted min. 15/32-inch plywood sheathing for new and existing construction
Roof Deck:
at may 24 in. span; In the HVHZ, new construction shall be min. 19132 in. plywood at max.
24 in. span; Designed by others in accordance with FBC requirements.
Underlayment:
Installed in accordance with FBC requirements. In the HVHZ, the minimum undedayment
shall be installed as described in RAS 118, RAS 119, or RAS 120, as applicable.
BOR18003
7of12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer snail notlty L;KhhK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL. SERVICES, LLC
BORAL ROOFING LLC
Concrete Roof Tiles
Data for Attachment Calculations for Direct to Deck Applications
Nominal Weight (W) and
Aerodynamic
Restoring' Moments due'to=Gravity- M9 (ft-tbf)
Dimensions (I xw)
Mul
Direct Deck
Roof Tile
_ - -
A (tiplsiers ft )
Diredt Deck
W (Ibf)
I (ft)
w(ft)
TAT
4":12"
5":12"
6":12"
>71:12"
Applicatior
Bermuda
9.7
1.33
0.833
0.205
6.97
6.86
6.71
6.54
6.35
Plantation
11.6
1.375
1.08
0.289
7.79
7.67
7.52
7.32
7.04
Saxony 900
10.9
1.417
1.08
0.315
7.62
7.5
7.34
7.16
6.95
Estate "S"
10.0
1.375
1.08
0.289
6.74
6.64
6.50
6.33
6.14
Villa 900
10.9
1.42
1.08
0.315
7.62
7.50
7.34
7.15
6.95
Barcelona
11.5
1.417
1.08
0.301
7.00
6.90
6.76
6.60
6.42
900
Galena
8.5
1.42
0.833
0.235
6.13
6.03
5.89
74
5.57
Spanish "S"
Spanish °S"
8.95
1.417
0.8125
0.233
5.93
5.83
5.70
E5.56
5.39
Nuevo
Data for Attachment, Calculations for Batten Applications
Nominal Weight W) and
Aerodynamic
_.
Restoring' Moments due to Gravity- Ma (ft-lbf)
Dimensions x w)
Multipliers
li
Direct Deck
Roof Tile
_
A (ft )
W (Ibf)
I•(ft)
w(ft)
Batten
3"12"
4°:12"
5":12"
6":12"
>7":12"
Application
Bermuda
9.7
1.33
0.833
0.189
6.53
6.43
6.29
6.14
5.97
Plantation
11.6
1.375
1.08
0.267
6.85
6.75
6.61
6.44
6.26
Saxony
10.9
1.417
1.08
0.291
-
6.61
6.48
6.31
6.13
900
Estate "S"
10.0
1.375
1.08
0.267
5.91
5.82
5.70
5.56
5.40
Villa 900
10.9
1.42
1.08
0.291
-
6.56
6.42
6.26
6.08
Barcelona
11.5
1.417
1.08
0.286
6.19
6.19
6.06
5.92
5.76
900
Spanish
8.95
1.417
0.8125
0.215
5.30
5.21
5.09
4.96
4.82
"S" Nuevo
BOR18003
8of12
This evaluation report is provided for State of Florida product approval under Rule 61G203. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
BORAL ROOFING LLC
Concrete Roof Tiles
Attachment Resistance Expressed as a Moment for Mechanically Fastened Applications
Tile Fastener
Mf.(ft-lbf)
Roof Tile
Direct Deck
'Direct Deck
Type
Count
Size
Shank
Clip
(min. 15132"
(min; 19132"
Battens
plywood)
plywood]
-
Nail
2
10d
Ring
N/A
30.9
38.1
17.2
Nail
1
10d
Smooth
N/A
7.3
9.8
4.9
or Screw
Nail
2
10d
Smooth
N/A
14.0
18.8
7.4
or Screw
Screw
1
#8
N/A
N/A
30.8
30.8
18.2
Bermuda,
Screw
2
#8
N/A
N/A
51.7
51.7
24.4
Plantation or
Saxony 900
Nail
1
10d
Smooth
Field
24.3
24.3
24.2
or Screw
Nail
1
10d
Smooth
Eave
19.0
19.0
22.1
or Screw
Nail
2
10d
Smooth
Field
35.5
35.5
34.8
or Screw
Nail
2
10d
Smooth
Eave
31.9
31.9
32.2
or Screw
Nail'
2
10d
Ring
N/A
50.3
65.5
48.3
Nail
2
10d
Ring
NIA
27.8
37.4
28.8
Nail
1
10d
Smooth
N/A
8.8
11.8
4.1
or Screw
Nail
2
10d
Smooth
N/A
16.4
21.9
7.1
or Screw
Screw
1
#8
N/A
N/A
25.8
25.8
22.9
Estate "S"2,
Screw
2
#8
NIA
NIA
47.1
47.1
49.1
Villa 900
Nail
1
10d
Smooth
Field
24.3
24.3
24.2
or Screw
Nail
1
10d
Smooth
Eave
19.0
19.0
22.1
or Screw
Nail
2
10d
Smooth
Field
35.5
35.5
34.8
or Screw
Nail
2
10d
Smooth
Eave
31.9
31.9
32.2
or Screw
Estate "S"
Nail'
2
10d
Ring
N/A
43.0
67.5
50.9
Continued on following page
BOR18003 FL28328 Page 9 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
BORAL ROOFING LLC
Concrete Roof Tiles
Attachment Resistance Expressed as a Moment for Mechanically Fastened Applications .
Tile,Fastener
Mr (ft-lbf)
Roof Tile
-
-
Direct Deck
.Direct Deck
Type
Count
Size
Shank
Clip
(min.15132"
(min.19/32"
Battens
plywood)
;plywood
-
Nall
2
10d
Ring
N/A
28.6
41.2
19.4
Nail
1
10d
Smooth
N/A
5.1
6.8
2.8
or Screw
Nail
2
10d
Smooth
N/A
6.9
9.2
7.3
or Screw
Screw
1
#8
N/A
N/A
20.7
20.7
18.1
Barcelona 900,
Screw
2
#8
N/A
N/A
43.2
43.2
29.8
Galena or
Spanish "S"
Nail
1
10d
Smooth
Field
23.1
23.1
19.0
Nuevo
or Screw
Nail
1
10d
Smooth
Eave
29.3
29.3
24.0
or Screw
Nail
2
10d
Smooth
Field
27.6
27.6
38.6
or Screw
Nail
2
10d
Smooth
Eave
38.1
38.1
41.8
or Screw
Nail'
2
10d
Ring
NIA
33.1
48.1
45.2
Notes: 1) Not for Saxony 900, Villa 900 or Barcelona 900. Installation Moth a Chia headlap and fasteners are located a mm, z-vz
from head of tile.
2) When using only one fastener, use the hole that is approximately 4-3/4" away from intedocking edge.
3) Direct Deck applications only.
Attachment'Resistance Expressed as a Moment forAdhesive or Mortar Set
Roof Tile
Adhesive
Product Approval'
Paddy
Count
Average Paddy
Weight (grams)
Mt (ft-lbf)
Dow Chemical TILE BONDTM
NOA 16-0222.01
2
13.9
31.3
Bermuda,
Planation and
Saxony 90D
Saxony
ICP Adhesives Polyset AH-160
NOA 17-0322.03
2
8
31.3
1
24
40.4
1
45
118.9
Saxony 900
DAP Foam Inc. Touch N' Seal®
Storm Boncl 2 Two -Component
'
NOA 17-0829.12
2
8
5
1
24
455
1
45
93
Premix Marbletite, Inc. TILE-TITE
NOA 17-1016.07
NIA
NIA
43.9
Dow Chemical TILE BONDTM
NOA 16-0222.01
2
11.4
26.1
Estate "S" or
Villa 900
ICP Adhesives Polyset AH-160
NOA 17-0322.03
2
8
26.1
1
24
45.5
1
54
86.61
Premix Marbletite, Inc. TILE-TITE
NOA 17-1016.07
N/A
NIA
20.6
Villa 900
DAP Foam Inc. Touch N' Seal®
Storm BondTM' 2 Two -Component
NOA 17-0829.12
2
8
55
1
30
40
1
60
70
BOR18003 FL28328 Page 1u of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERv1_CEs, LLC
BORAL ROOFING LLC
Concrete Roof Tiles
Attachment Resistance F- pressed, as a Moment for Adhesive or Mortar Set
Roof Tile
Adhesive
Product Approval'
Paddy
Count
AveragePaddy
Weigh_ t (grams) !
Mf (ft
Dow Chemical TILE BONDTM
NOA 16-0222.01
2
10.7
29.3
Barcelona 900,
Galena Spanish
"S" or Spanish
"S" Nuevo
ICP Adhesives PolysetAH-160
-NOA 17-032203
2
8
29.3
1
24
38.7
1
63
66.5
Premix Marbletite, Inc. TILE-TITE
NOA 17-1016.07
N/A
N/A
24.5
Barcelona 900
DAP Foam Inc. Touch N, Seal®
Storm BondTM 2 Two -Component
NOA 17-0829.12
2
8
66.0
1
30
63
1
60
82
Notes: i ) bee manutacturers procucr appmvar Tor mstanauon requirement,.
LABELING
1) All tiles shall bear the identifiable marking of the manufacturer's name or logo as follows:
Manufactured in Lake Wales, FL
Manufactured in Okeechobee, FL
\� NTESRA 6
BOR78003 FL28328 Page 11 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G203. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
o _TECHNICAL SERVICES, LLC
LIMITATIONS
BORAL ROOFING LLC
Concrete Roof Tiles
1) Fire Classification is not within the scope of this evaluation.
2) Installation of the evaluated products shall comply with FBC Section 1507.3, FRSAfrRI Florida High Wind
Concrete and Clay Roof Tile Installation Manual, Fifth Edition Revised and the manufacturer's published
application instructions. Installations in the HVHZ shall comply with RAS 118, RAS119 and RAS 120.
3) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
4) All product listed in this shall tested quarterly in accordance with TAS 112 Appendix A.
5) Installation of the evaluated products shall be limited to projects in areas subjected to weathering indices of
50 or greater as illustrated in ASTM C 1492-03, figure 1 (see below).
50
WEATHERING REGIONS N*Y
0 NEGLIGIBLE WEATHERING
MODERATE WEATHERING
SEVERE WEATHERING
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R Priest P.E. have demonstrated compliance with the Florida Building
Code, 6" Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
00IIIIIII, fill
'VQ': �.v SF•. cP�':
No 74021
*; :*
* = /f 2018.10.15
9 STATE OF :.tub X7r//f� 19:51:52
Cl
siONAll � � �,, Fonda Registration No. 74021
Organization No. ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial Interest in any other entity involved in the approval process of the
product.
END OF REPORT
BOR18003 FL28328 Page 12 of12
This evaluation report is provided for State of Florida product approval under Rule 611320-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is vaid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
EXTERIOR RESEARCH & DESIGN, U.C.
Certificate of Authorization #9503
SCANNED 353 CHRISTIAN STREET, UNIT 13
TRINI� ERD
BY OXFORD, CT
St. Lucie County (203) 262-9245
EVALUATION REPORT
ICP Adhesives and Sealants, Inc. Evaluation Report 02768.03.06-Rg
12505 NW 44th Street FL6332-R8
Coral Springs, FL 33065 Date of Issuance: 08/08/2008
(888)774-1419 Revision 8:10/12/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 61h Edition (2017) Florida Building Code sections noted herein.
DESCRIPTION: ICP Adhesives Polyset® AH-160
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words 'Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer Or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 9.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DC4ANE1983
The facsimile seal appearing was authorized by Robert
Nieminen, P.E. on 10/12/2017. This does not serve as an
electronically signed document
CERTIFICATION OF INDEPENDENCE:
1. Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest
in any company manufacturing or distributing products it evaluates.
2. Exterior Research & Design, LLC d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or
distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither Trinity] ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINIY ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category:. Roof Tile. Adhesives.
Compliance Statement: ICP Adhesives Polyset® AH-160, as produced by ICP Adhesives and Sealants, Inc., has
demonstrated compliance with the 6eh Edition (2017) Florida Building Code through testing in accordance with the
Standards set forth herein. Compliance is subject to the Installation Requirements and Limitations / Conditions of
Use set forth herein.
2. STANDARDS:
Sections Pro a Standard Year
1504.2.1.1 Overturning resistance SSTD 11 1997
3. REFERENCES:
Entity
Examination
Reference
Date
ERD (TST 6049)
Static Uplift —SSTD 11
P39740.02.12
02/20/2012
ERD (TST 6049)
Static Uplift —SSTD 11
P39740.11.13-Ri
01/02/2015
ICC-ES (EVL2396)
2012 IBC Compliance
ESR-1709
12/01/2016
Miami -Dade (CER 1592)
HVHZ compliance
17-0322.03
04/27/2017
PRI (TST 5878)
Static Uplift —SSTD it
ECM-001-02-01
09/21/2001
PRI (TST 5878)
Static Uplift —SSTD 11
PFI-006-02-01
05/09/2005
PRI (TST 5878)
Static Uplift —SSTD 11
PFI-006-02-02
05/09/2005
PRI (TST 5878)
Static Uplift —SSTD 11
PFI-007-02-01
10/11/2005
PRI (TST 5878)
Static Uplift —SSTD 11
PFI-008-02-04
02/21/2006
PRI (TST 5878)
Static Uplift —SSTD 11
PFI-009-02-03
02/21/2006
PRI (TST 5878)
Static Uplift —SSTD 11
TGRI-001-02-03
10/30/2006
PRI (TST 5878)
Static Uplift —SSTD 11
TGRI-001-02-03
10/30/2006
PRI (TST 5878)
Static Uplift —SSTD 11
PFPI-010-02-01
12/07/2006
PRI (TST 5878)
Static Uplift —SSTD 11
PFPI-011-02-01
12/07/2006
PRI (TST 5878)
Static Uplift —SSTD 11
PFPI-012-02-01
12/07/2006
PRI (TST 5878)
Static Uplift —SSTD 11
PFPI-013-02-01
12/07/2006
PRI (TST 5878)
Static Uplift —SSTD 11
PFPI-014-02-01
12/07/2006
PRI (TST 5878)
Static Uplift —SSTD 11
ECM-003-02-01
06/13/2008
PRI (TST 5878)
Static Uplift —SSTD 11
ECM-004-02-01
06/13/2008
PRI (TST 5878)
Static Uplift —SSTD 11
ECM-005-02-01
06/13/2008
PRI (TST 5878)
Static Uplift —SSTD 11
ECM-006-02-01
06/13/2008
PRI (TST 5878)
Static Uplift —SSTD 11
ECM-007-02-01
06/13/2008
PRI (TST 5878)
Static Uplift —SSTD it
ECM-008-02-01
06/13/2008
UL LLC (QUA 9625)
Quality Assurance
Service Confirmation
Exp. 06/05/2018
4. PRODUCT DESCRIPTION:
4.1 ICP Adhesives Polyset® AH-160 is a two -component expanding polyurethane roof tile adhesive that is mixed
and dispensed from a dispensing system provided by ICP Adhesives and Sealants, Inc. The components are
available in refillable tanks or disposable cylinders (ICP Adhesives PrOPack® 30 & 100).
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity( ERD nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for
permitting or design guidance unless retained specifically for that purpose. '
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
Exterior Research and Design, U.C. Evaluation Report 02768.03.06-RS
Cert♦&ate ofAuthodzodon N9503 a EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-R8
ICP Adhesives Polyset® AH-160, (988) 774-1429 Revision 8: 10/12/2027
Page 2 of 9
TRIN TV ERD
5.3 Fire classification is not part of this evaluation. Refer to a current Roofing Materials Directory for fire ratings
of this product and FBC 1505.2.
5.4 ICP Adhesives Polyset® AH-160 can be used with flat, low and high profile tiles or any rigid, discontinuous roof
assembly having a current Florida Statewide Product Approval or approved on a local -level by the Authority
Having Jurisdiction.
5.5 Minimum underlayment shall be per FRSA/TRI April 2012 (04-12) or having a current Florida Statewide
Product Approval or approved on a local -level by the Authority Having Jurisdiction for use with ICP Adhesives
Polyset® AH-160.
5.6 Field tiles, meeting the limitations of FBC 1609.5.3, using ICP Adhesives Polyset® AH-160 are limited to
projects having an Aerodynamic Uplift Moment (M,), determined in accordance with FBC 1609.5.3 or Tables
2A and 2B of FRSA/TRI April 2012 (04-12), not greater than the following Allowable Overturning Moment
values. Refer to Section 10 and ICP Adhesives and Sealants, Inc. published installation instructions for
Adhesive Paddy Placement details.
TABLE 1: FIELD TILES IN ICP ADHESIVES POLySETo AH-160
ALLOWABLE OVERTURNING MOMENT PERFORMANCE DATA
2 TO MARGIN OFSAFETYALREADYAPPDED FORINDEPENDENT (SINGLE OR CONTINUOUS PADDY) PLACEMENT
4 TO MARGINOFSAFETYAMIADYAPPLIED FOR /NTERDEPENDENr(TWO PADDY) PLACEMENT
Tile (FBC 1609.5.3)
Adhesive Paddy Placement
Allowable
Overturning
Type
Profile
Moment(ft-lbf)
Independent; Single Paddy, Medium (20-inch, -30 gram)
60
Clay or
Flat
Independent; Single Paddy, Large (2x10-inch, -45 gram) -
112
Concrete
Interdependent; Two Paddy (4x4-inch on underlayment, 2x44nch at the overlap)
54
Independent; Single Paddy, Medium (2x7-inch, -30 gram)
39
Clay or
Low/
Independent; Single Paddy, Large (2x10-inch, -54 gram)
67
Concrete
Medium
Interdependent; Two Paddy (44-inch on underlayment, 2x4-inch at file overlap)
58
Clay
High
Independent; Single Paddy, Large (2x10-inch, -45 gram)
134
Independent; Single Paddy, Medium (2x7-inch, -30 gram)
65
Clay or
High
Independent; Single Paddy, Large (2x10-inch, `63 gram)
109
Concrete
Interdependent; Two Paddy (4x4-inch on underlayment, 2z4-inch at file overlap)
40
Clay
Barrel
2x10-inch x `35 gram for pans; 2 @ 1x10-inch x ^17 gram for cap
147
Concrete
Barrel
2x10-inch x -35 gram for pans; 2 @ 1x10-inch x ^17 gram for cap
107
Clay
Cap atop 2x
Independent: Continuous Paddy (-'34 gram/ft)
135
stringer
Concrete
Cap atop 2x
Independent: Continuous Paddy ("'34 gram/ft)
116
stringer
ClayCap
atop 2x
Interdependent:
105
stringer
Head: One (1) #SO x 2W screw; Overlap: 1 x 6 inch (-10.5 gram)
Concrete
Cap atop 2x
Interdependent:
76
stringer
Head: One (1) #10 x 2W screw, Overlap: 1 x 6 inch (^50.5 gram)
5.6.1 Data in Table 1 relates to installation over a '30/90' underlayment system, as detailed in the FRSA/TRI April
2012 (04-12). Alternate underlayment systems include those having a current Florida Statewide Product
Approval and/or approved on a local -level by the Authority Having Jurisdiction specifically for use with ICP
Adhesives PolysetO AH-160.
5.6.2 Tile roof systems using tile types or profiles other than those listed above acquiring acceptance for use with
ICP Adhesives Polyset® AH-160 shall be tested in accordance with SSTD 11 or Testing Application Standard
TAS 101. For the interdependent two -paddy method, an additional 2-to-1 margin above that specified in
SSTD 11 or Testing Application Standard TAS 101 shall be applied in determining the 'allowable overturning
moment'.
Exterior Research and Design, U.C. Evaluation Report 02768.03.06-118
rern7imte of Authorization 99503 6n` EDITION (2017) FBC NON.HVHZ EVALUATION F1.6332-118
ICP Adhesives Polyset• AH-160; (888) 774-1419 Revision 8: 10/12/2017
Page 3 of 9
TRINITY ERD
5.7 Hip and ridge tiles using ICP Adhesives Polyset® AH-160 are limited to projects having hip/ridge design pressure
requirements, determined in accordance with Table 1A of FRSA/TRI April 2012 (04-12), not greater than the
following values. Refer to ICP Adhesives and Sealants, Inc. published installation instructions for Adhesive
Paddy Placement details.
TABLE 2[ HIP & RIDGE TILES IN ICP ADHESIVESPOLYSET's AH460
ALLOWABLE UPLIFT RESISTANCE PERFORMANCE DATA
2 TO MARGIN OFSAFETYALREADYAPPLIED FOR INDEPENDENT (CONTINUOUS PADDY) PLACEMENT
4To l MARGIN OFSAFETYALREADYAPPUED FOR INTEROEPENDENTPLACEMENT
Allowable
Tile
Substrate
Attachment Method
Design Pressure
(psf)
Clay
2x PT ridge board
Independent: Continuous Paddy (`34 gram/ft)
116
Concrete
2x PT ridge board
Independent: Continuous Paddy (- 34 gram/ft)
107
Interdependent: Head: One (1) #10 x 2X" screw;
90
Clay
2x PT ridge board
Overlap: 1 x 6 inch (-10.5 gram)
Interdependent: Head: One (1) #10 x 2W screw;
56
Concrete
2x PT ridge board
overlap: 1 x 6 inch (-10.5 gram)
Clay or
Hip & Ridge Channel Metal (FL5374):
Independent: Continuous Paddy (^34 gram/ft)
169
Concrete
galvanized only
Clay or
Trim Lock'" (FL5374): aluminum,
Independent: Continuous Paddy ('"34 gram/ft)
173
Concrete
galvanized, Golvalumeo or stainless steel
Clay or
Trim LockTM Plus (FL5374): aluminum,
Independent: Continuous Paddy (` 34 gram/ft)
178
Concrete
galvanized, Galvalume® or stainless steel
Clay
Top Notch (FL8095)
Independent: Continuous Paddy (` 32 gram/ft)
125
Concrete
Top Notch (FL8095)
Independent: Continuous Paddy (- 32 gram/ft)
146
6. INSTALLATION:
6.1 ICP Adhesives Polyset® AN-160 and the the roof assembly shall be installed in accordance with FRSA/TRI
April 2012 (04-12) and ICP Adhesives and Sealants, Inc. published installation instructions, subject to the
limitations outlined in Section 5.
6.2 Hip and ridge boards or hip/ridge metal shall be installed in accordance with the FRSA/TRI April 2012 (04-12).
Proprietary hip and ridge metal shall be installed in accordance with the manufacturer's Florida Product
Approval.
6.3 Installation shall be performed by applicators who hold a valid Qualified Applicator Card presented by ICP
Adhesives and Sealants, Inc.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the
installation of this product.
8. MANUFACTURING PLANTS:
Tomball, TX
9. QUALITY ASSURANCE ENTITY:
UL, LLC. - QUA9625; (847) 664-3623; LeAnna.Gradecki@ul.com
Exterior Research and Design, U.C. Evaluation Report 02768.03.06-R8
Certilkz ofAuthorizodon R9503 a EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-R8
ICP Adhesives Polyset® AH-160; (888) 774-1419 Revision 8: 10/12/2017
Page 4 of 9
- - - - ---- - TRINITY ERD - -
10. PADDY PLACEMENT DETAILS (FROM ICP ADHESIVES AND SEALANTS, INC. PUBLISHED LITERATURE):
10.1 Independent, Medium Paddv:
Nail through plastic cement Paddy (Beneath Tile)
(when required),
Underlayment
o ..
7 in.
ms optional
Course,
�2 ini,
Flat/Low Profile Tile
s
\
plastic cement
ad)
Paddy (Beneath Tile)
rt `•mil'.
F
Battens optional:
torn
t
%c Eave Closure
.��
Eave Course `aJ� j / Fascia
Medium Profile Tile
Nail through plastic cemerrt- - paddylBeneath Tile)
(when required)
Underiayment��
7 inns' �' - �• �--.,
f 2 in.
optional Battenso
P \ 6
\'
Eave Course ~-'� r�\F�
�� � � s `• � � Fascia
Weephole
10 in. 2in. /x Eave closure
' Drip edge
High Profile Tile
Exterior Research and Design, U.C. Evaluation Report 02768.03.06.118
Certficate of Authorization 09503 6rx EDITION (2017) FBC NON-HVH2 EVALUATION FL6332-RB
ICP Adhesives Polyseto AH-160; (889) 774-1419 Revision 8: 20/12/2017
Page 5 of 9
10.2 Independent, Large Paddv:
Nail through plastic cement Paddy (Beneath Tile)
(when required),
Underlayn ent10,
/c;---� •1�
/-
i
Battens opt Iona]
Eave Course �
Eave gosure
Flat/Low Profile Tile
TRINITY ERD
Nail through plasticcement
(when required)
j Paddy (Beneath Tile)
Underlayment t•• '``
4
�a
2 in.vnde
Battens optional (�
tin. /✓�
• ' - ; .- � /� Eave Closure
Eave<ourse i fascia
Medium Profile Tile
Nail through plastic cement\
(when required) Paddy (Beneath Tile)
Underlayment
2�in.wide X
Battens
oZC/Eay.
tional
�F\ \
ourse\i`„� Fascia
x/ .
•Eave closure
weephole
1-,,�_',2 in / i
Drip edge it
Nigh ProfileTile
Exterior Research and Design, U.C. Evaluation Report 02768.03.06-118
certijinue o)Authadredon #9503 bra EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-R8
ICP Adhesives Polyset° AH-160; (888) 774-1419 Revision 8: 10/12/2017
Page 6 of 9
10.3 interdependent, Two Paddy:
Nail through plastic cement _ Paddy (between tiles}
(when required) /\\
\ a \
Battens optional
{ /a \j Paddy (under tile)
Single[ addy V, j
\ 4 efttop.ftile j !
4x4in
14 SinglepaddY�
undartil
Sie paddy /
on underlayment 2x4in.�
V loin?'�Fascia
y A,
Eve Closure
Flat/Low Profile Tile
TRINITY ERD -
Nail through plastic cement Single Paddy under file
(when required)
Paddy (between tiles)
Battens �� r�� \ / Paddy (under tile]
optional
srn [op or me.
W4x4 in.
Single paddy on
underlayment/
r`
Eave Coursc�
x4in.'
j�� Eave Closure
r� Fascia
Medium Profile Tile
Nail through plastic cement\ Single paddyunder tile
(whenregCited) /
\\i \ Paddy(betweentiles)
Battens „ate' x Paddy (under tile)
optional l'v'
.n
Y Single paddy
on underlayment\ ,{.^�Y, \
.� 4x4in.
%' • ; \x
Single 2z4in..
Eave Course\\\� •, ..<
yy�i jX Fascia
I Weephole
Eave Closure
to in. a2 in
yj Drip ed e
'. P 9
High ProftieTile
Exterior Research and Design, LLC. Evaluation Report 02768.03.06-R8
Ceralsarte of Authorization A9503 6t"EDITION (2017)FBC NON-HVHZ EVALUATION FL6332-RS
ICP Adhesives Poiysete AH-160; 1888) 774-1419 Revision 8: 10/12/2017
Page 7 of 9
1
10.4 Two Piece Barrel (Cap & Pan) Tile:
11 Place enoughadhesiveto achieve 65 to 70
in contact with the pan tile.
YI Tom Corers upside de+m. Mace adheirve
12 in. ro 1 ism in from Minns edge of cover lac.
Ina.+liceverlio
Ensure. f15 sq.in. cana.cacilad amaao'-r---Y
Erem,deofce"A...
Iundedayment 1
(mororshownl
Weephole Fascia Board
Remove top portion of the cave course cover tile. Abut to second course of
Ron rites. Ensure eave end of pan and cover tiles are Bush at save line.
Two Piece Barrel - High Profile Tile
10.5 Hip and Ridge (independent placement):
Ah-.ul oflCP PnI;.-Ii Al 1.]., c:.l btalpi-d dear Cu•GLI To=,liLc,Ed.f_e 11-, o h.d oflCP Pu:ys¢AlHnu mr;
Weauri:ev:111:9 hd draul§rcmeTnl me 1',W"b,J m::ha;vrvl
u<ulhsasbmuw!r n�a;l.vt4¢:m: fnm+.
Exterior Research and Design, LLC.
Certljtcote of Authorization R9503 Ern EDITION (2017) FBC NON-HVHZ EVALUATION
ICP Adhesives PoWsete AH-160: (888) 774-1419
TRINITY( ERD - - -
Evaluation Report 02768.03.06•RB
FL6332-R8
Revision 8: 20/12/2017
Page 8 of 9
TRINITY ERD
10.6 Hip and Ridge (interdependent placement):
1" X 6" Bead of ICP
Polyset°AH-160
:! roof tile adhesive
#10 x 2-1/2" Screw
Code Approved
�n Fastener
VN„
Adhere starter
tile with a 2" x 7"
Paddy placed 3"
down from head
�:.
-% of the
- END OF EVALUATION REPORT -
Exterior Research and Design, U.C.
Ce"tate ofAuthori:otion a9503 6'" EDITION (2017) FBC NON-HVH2 EVALUATION
ICP Adhesives Polyseto AH-160; (898) 774-1419
Evaluation Report 02768.03.06-R8
FL6332-RB
Revision 8: 30/12/2017
Page 9 of 9
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate ofAathorizotion #9503
SCANNED 353 CHRISTIAN STREET, UNIT#13
TRINffy ERD BY OXFORD, CT 06478
St. Lucie County PHONE: (203) 262-9245
FAX: (203) 262-9243
EVALUATION REPORT
East Coast Metals, Inc. Evaluation Report E10240.08.08-R4
2301 West 8 Lane FL5374-114
Hialeah, FL 33010 Date of Issuance: 09/03/2008
Revision 4: 03/17/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein.
DESCRIPTION: East Coast Metals Channel Metals
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. Trinity ERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPErnoN: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by:
RobertJ.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appea fte,as oWuoraed by Robert Nieminen,
P.Epna9/17/20M ThedoesiaaserveasaneleNonioRysiVed
document. Sided, min hes rap havemmed ieM to Ne
PmduRApprwal Admin'smamraiM to the named tliem
CERTIFICATION OF INDEPENDENCE:
1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity] ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Roofing Accessories that are an Integral Part of the Roofing System
Compliance Statement: East Coast Metals Channel Metals, as produced by East Coast Metals, have demonstrated compliance
with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance
is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1507.3.7
Installation, non-HVHZ
FRSA/TRI April 2012 (04-12)
2012
1518.8.1
Installation, HVHZ
RA5118, 119 & 120
1995
1523.6.5.2.2
Static Uplift Resistance
TA5301
1995
1711.2.1
Static Uplift Resistance
SBCCI SSTD 11
1997
3. REFERENCES:
911titt
Examination
Reference
Date
ERD(TST6049)
Static Uplift Resistance
E42730.08.13
08/23/2013
ERD(TST6049)
Static Uplift Resistance
ECM-SC6795.12.14-1
02/27/2015
ERD (TST6049)
Static Uplift Resistance
ECM-SC6795.12.14-2
02/27/2015
Florida TEC (TS17393)
TAS 101
S10-628R
10/27/2010
PRI (TST5878)
TAS 101
ECM-001-02-01
09/21/2001
PRI (TST5878)
TAS 101
ECM-003-02-01
06/13/2008
PRI(TST5878)
TAS 101
ECM-004-02-01
06/13/2008
PRI (TST5878)
TA5101
ECM-005-02-01
06/13/2008
PRI (TST5878)
TA5101
ECM-006-02-01
06/13/2008
PRI (TST5878)
TAS 101
ECM-007-02-01
06/13/2008
PRI(TST5878)
TAS 101
ECM-008-02-01
06/13/2008
Florida Building Code
Attachment Requirements
FRSA/rRl April 2012 (04-12)
04/2012
Florida Building Code - HVHZ
Attachment Requirements
RA5118, 119 and 120
1995
East Coast Metals
Metal Quality
Mill Certifications
Various
Architectural Testing(QUA1844)
Quality Control
Participation Letter
Exp. 12/31/2018
4. PRODUCT DESCRIPTION:
4.1 Hip & Ridge Channel Metal: Pre -formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof tile adhesive.
Hip & Ridge Channel Metal is available in 119-3/8-inch L
3/8-inch) length by 2.5, 3, 3.5, 4, 5, 6 or 7-inch L 3/8-inch)
heights with 1.5-inch L+1/16-inch) deck -flanges.
Exterior Research and Design, U.C. Evaluation Report E10240.08.08-R4
cert//lcare ofAuthoruadon e9503 FL5374-R4
Revlsion 4: 03/17/2015
Page 2 of 7
TRIN" ERD
4.2 Trim Lock Channel Metal: Pre -formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof tile adhesive. Trim Lock
Channel Metal is characterized by its profiled and
perforated upper horizontal flange designedto receive
and allow for interlock with the overlying tile adhesive.
Trim Lock Channel Metal is available in 119-3/8-inch L
3/8") length by 3, 3.5, 4, 5 or 6-inch (± 3/8-inch) heights
with 1.5-inch (± 1/16-inch) deck -flanges.
4.2 Trim Lock Plus Channel Metal: Pre -formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof file adhesive. Trim Lock
Plus Channel Metal is characterized by its profiled and
perforated upper horizontal flange designed to receive
and allow for interlock with the overlying tile adhesive
and its perforated deck flanges, designed for installation
atop the roof underlayment via placement in FBC
Approved roof tile adhesive, which flows -through and
interlocks with the underlying adhesive.
Trim Lock Plus Channel Metal is available in 119-3/8-inch
(± 3/8") length by 3, 3.5, 4, 5 or 6-inch (±3/8-inch) heights
with 1.5-inch (±1/16-inch) deck -flanges.
4.4 East Coast Metals Channel Metals are fabricated of the following metals:
➢ Galvanized Steel: Min. 0.019±0.002-inch, ASTM A653 (G-90), min. 33 K51.
➢ Galvalume Steel: Min. 0.019±0.002-inch, ASTM A792, A255, min. 35 KSI.
➢ Aluminum: Min. 0.032 ±0.002-inch, ASTM B209, 3003-H14, min. 21 K51.
➢ Stainless Steel: Min. 0.019±0.002-inch, ASTM A240/A480, T304, min. 35 KSI.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
Exterior Research and Design, LLC. Evaluation Report E30240.08.08-R4
CertiftmW o)Aurhorization #9503 FL5374-R4
Revision 4: 03/17/201S
Page 3 of 7
TRIM I'( ERD
5.2 FOR HVHZ JURISDICTIONS:
5.2.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FBC RAS 118, Drawing 13, Detail 3; RAS 119,
Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3. For Trim Lock Plus Channel Metal, refer to the installation
instructions herein.
5.2.2 For HVHZ jurisdictions, installations of Hip & Ridge Channel Metal and Trim Lock are prescriptive by RAS 118, 119 and
120, and the datainTables IA and IS is supplemental to these prescriptive allowances.
Installations of Trim Lock Plus are limited to projects having a required moment resistance (Mr) or uplift resistance (F,),
as determined in accordance with RAS 127, not greater than the following values.
Refer to the tile adhesive manufacturer's published installation instructions for adhesive paddy placement details.
➢ "INDEPENDENT" paddy placement means each individual tile is banded to the Channel Metal in its own, single
foam paddy; tile head laps are not bonded. This method is limited to 2-part tile adhesives. Allowable
performance data below for "INDEPENDENT" paddy placement already has a 2 to 1 margin of safety applied to
ultimate performance.
➢ "INTERDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy,
and a second foam paddy bonds the tile head lap, or two tiles are bonded to the Channel Metal using a single
foam paddy. Allowable performance data below for "INTERDEPENDENT" paddy placement already has a 4 to 1
margin of safety applied to ultimate performance.
TABLE IA: PERFORMANCE LIMITATIONS- HVHZ, INDEPENDENT PADDY PLACEMENT
(2 TO 1 MARGIN OFs4FETYALRFADYAPPUED)
Hip/Ridge Metal
Tile
Adhesive
Allowable Performance
Moment Based
Uplift Based
Design
Metal Type
Type
Placement
Mr(ft-Ibf)
F'(Ibf)
Hip & Ridge
galvanized
day or
3MTM 2-Component Foam
Independent
127
169
Channel Metal
concrete
Roof Tile Adhesive AH-160
Trim Lock
galvanized, Galvalume°,
clay or
3MTM 2-Component Foam
Independent
171
159
aluminum or stainless steel
concrete
Roof Tile Adhesive AH-160
Trim Lock Plus
galvanized, Galvalume®,
day or
3MTM 2-Component Foam
Independent
p
177
165
aluminum or stainless steel
concrete
Roof Tile Adhesive AH-160
TABLE IS: PERFORMANCE LIMITATIONS-HVHZ, INTERDEPENDENT PADDY PLACEMENT
(4 TO MARGIN OFMFETYALREAOVAPPLIEu)
Hip/Ridge Metal
Tile
Adhesive
Allowable Performance
Moment Based
Uplift Based
Design
Metal Type
Type
Placement
Mt (ft-lbf)
F' (Ibf)
Trim Lock or Trim
galvanized, GalvalumeO,
day or
3MTM 2-Component Foam
Interdependent
95
88
Lock Plus
aluminum or stainless steel
concrete
Roof Tile Adhesive AH-160
Trim Lock
galvanized, Galvalume®,
day or
3MTM Roof Tile Adhesive
Interdependent
99
94
stainless steel
concrete
RTA-1
Trim Lock
aluminum
clay or
310TM Foam Roof Tile
Interdependent
90
84
concrete
Adhesive RTA-1
Trlm Lock Plus
galvanized, Galvalume•,
day or
3MTM Foam Roof Tile
Interdependent
90
S4
aluminum or stainless steel
Concrete
Adhesive RTA-1
Trim Lock
galvanized, Galvalume®or
day or
TILE BOND"' Roof Tile
Interdependent
123
117
stainless steel
concrete
Adhesive
Trim Lack
aluminum
day or
TILE BONDTM Roof Tile
Interdependent
79
73
concrete
Adhesive
Trim Lock Plus
galvanized, Galvalume•,
day or
TILE BOND'" Roof Tile
Interdependent
79
73
aluminum or stainless steel
concrete
Adhesive
Trim Lock
galvanized, Galvalume°or
day or
Touch'n Seal StormBond
Interdependent
14fi
139
stainless steel
concrete
Roof Tile Adhesive
Trim Lock
Aluminum
day or
Touch'n Seal StormBond
Interdependent
58
54
concrete
Roof Tile Adhesive
Tdm Lock Plus
galvanized, Galvalume•,
clay or
Touch'n Seal StormBond
Interdependent
58
54
aluminum or s[ainless steel
concrete
Roof Tile Adhesive
Exterior Research and Design, U.C. Evaluation Report E10240.08.08-R4
Certificate ofAuthorizotion rr9S03 FL5374-R4
Revision 4: 03/17/2015
Page 4 of 7
TRINI-Fy ERD
5.3 FOR NON-HVHZ JURISDICTIONS:
5.3.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FRSA/TRI April 2012 (04-12). For Trim Lock Plus
Channel Metal, refer to the installation instructions herein
5.3.2 For non-HVHZ, installations are limited to projects having hip and ridge design pressure requirements, determined in
accordance with Table 3A of FRSA/TRI April 2012 (04-12), not greater than the following values. Refer to the tile
adhesive manufacturers published installation instructions for adhesive paddy placement details.
➢ "INDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in its own, single
foam paddy; tile head laps are not handed. This method is limited to 2-part tile adhesives. This method is limited
to 2-part tile adhesives. Allowable performance data below for "INDEPENDENT" paddy placement already has a 2
to 1 margin of safety applied to ultimate performance.
➢ "INTERDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy,
and a second foam paddy bonds the tile head lap, or two tiles are bonded to the Channel Metal using a single
foam paddy. Allowable performance data below for "INTERDEPENDENT" paddy placement already has a 4 to 1
margin of safety applied to ultimate performance.
TABLE 2A: PERFORMANCE LIMITATIONS—NON-HVHZ, INDEPENDENT PADDY PLACEMENT
(2 To 1 MARGINOFSAFETYALREAUYAPPNED/
Hip/Ridge Metal
Tile
Adhesive
Allowable Uplift
IPsf)
Design
Metal Type
Type
Placement
Hip & Ridge
galvanized
clay or
310- 2-Component Foam Roof
Independent
169
Channel Metal
concrete
Tile Adhesive AH-160
Trim Lock
galvanized, Galvalume®, aluminum or
clay or
310- 2-Component Foam Roof
Independent
173
stainless steel
concrete
Tile Adhesive AH-160
galvanized, Galvalume®, aluminum or
clay or
3M- 2-Component Foam Roof
Independent
p
178
Trim Lock Plus
stainless steel
Concrete
Tile Adhesive AH-160
-
TABLE2B: PERFORMANCE LIMITATIONS—NON-HVHZ, INTERDEPENDENT PADDYPLACEMENT
(4 TOl MARGINOFSAFETYALREADYAPPNED)
Hip/Ridge Metal
Tile
Adhesive
Allowable Uplift
(Psf)
Design
Metal Type
Type
Placement
Trim Lock or Trim
galvanized, Galvalume', aluminum or.
clay or
3M"'2-Component Foam Roof
Interdependent
98
Lock Plus
stainless steel
Concrete
Tile Adhesive AH-160
Trim Lock
galvanized, Galvalume• or stainless
clay or
3M"' Foam Roof Tile Adhesive
Interdependent
110
steel
concrete
RTA-1
Trim Lock
aluminum
clay or
3M'" Foam Roof Tile Adhesive
Interdependent
93
concrete
RTA-1
Trim Lack Plus
galvanized, Galvalume•, aluminum or
clay or
3M- Foam Roof Tile Adhesive
Interdependent
93
stainless steel
concrete
RTA-1
Trim Lock
galvanized, Galvalume• orstainless
clay or
TILE BOND`" Roof Tile Adhesive
Interdependent
152
steel
concrete
Trim Lock
aluminum
clay or
TILE BOND'" Roof Tile Adhesive
Interdependent
82
Concrete
Trim Lock Plus
galvanized, Galvalume®, aluminum or
clay or
TILE BOND"' Roof Tile Adhesive
Interdependent
82
stainless steel
concrete
Trim lack
galvanized, Galvalume• orstainless
clay or
Touch'n Seal StarmBond Roof
Interdependent
148
steel
Concrete
Tile Adhesive
Trim Lock
Aluminum
clay or
Touch'n Seal StormBond Roof
Interdependent
61
concrete
Tile Adhesive
Trim Lock Plus
galvanized, Galvalume°, aluminum or
clay or
Touch'n Seal Storm Bond Roof
Interdependent
61
stainless steel
concrete
Tile Adhesive
Etderior Research and Design, LLC Evaluation Report E30240.08.08-1114
Certijiorte ofAuthomadon R9503 FL5374-R4
Revision 4: 03/17/2015
Page 5 of 7
TRINITY ERD
6. INSTALLATION:
6.1 The roof deck shall be minimum 15/32-inch plywood (non-HVHZ) or minimum 19/32-inch plywood (HVHZ) attached in
accordance with FBC Chapter 23 to the satisfaction of the AHI.
6.2 Hip & Ridge Channel Metal and Trim Lock Channel Metal shall be installed using min. 11 ga. x 1%-inch long x 3/8-inch
head diameter galvanized annular ring shank nails spaced 6-inch o.c. along both deck -flanges. Fasteners shall be
positioned %-inch from the outside edge of each deck -flange, set in a bed plastic roof cement. For FBC HVHZ, refer to
FBC RAS 118, Drawing 13, Detail 3; RAS 119, Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3.
6.3 Trim Lock Plus Channel Metal shall be installed atop the Approved roof underlayment in continuous 2-inch wide ribbons
of tile adhesive centered beneath each 1.5-inch wide deck flange. Place the Trim Lock Plus Channel Metal into the wet
adhesive and allow it to set-up prior to installation of roof tiles.
..:::.................................
View of Polyset AH160 Placement for Trim Lock Plus Channel Metal Installation
6.3.1 It is critical that the bond between the Trim Lock Plus Channel Metal, the tile adhesive and the underlayment is not
disturbed prior to or during placement of the ridge tiles.
6.3.2 Approved underlayments are the codified '30/90' system or other FBC Approved roof underlayments listing approved
use of the subject tile adhesive.
Exterior Research and Design, LLG Evaluation Report E30240.08.08-R4
[ertiilmte of Authorization#95e3 FL5374-R4
Revision 4:03/17/2025
Page 6 of 7
TRINITY ERD
6.4 Tile shall be installed atop the Channel Metal in accordance with the tile adhesive manufacturers Approved, published
installation instructions, subject to the limitations outlined in Section 5 herein. The exposed edges shall be packed and
pointed with Approved mortar or weather blocking adhesive in accordance with FRSA/TRI April 2012 (04-12) or RAS
118, RAS 119, RAS 120 requirements.
dge Tile
Tile Adhesive
2 4 Trim Lock Plus
.... ' '•:. " a�— Mortar or Weather Block
Adhesive
'.- �+Tile Adhesive
View of Trim Lock Plus Channel Metal Installation after Weather Blocked
6.4.1 Channel -Metal shall be free of dust, debris, oils or other bond -breaking substance prior to placement of adhesive.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 CIA requirements.
9. QUALITY ASSURANCE ENTITY:
Architectural Testing, Inc.—QUA1844; (717) 764-7700
END OF EVALUATION REPORT -
Exterior Research and Design, U.C.
CeAT#=W ojAuthorizatim 09503
Evaluation Report E30240.08.08-R4
FL5374-R4
Revision 4: 03/17/2015