EVALUATION REPORT
Polyglass USA, Inc. - Evaluation Report P12060.02.09-R24
1111 West Newport Center Drive FL52S9-R28
Deerfield Beach, FL 33442 Date of Issuance: 02/24/2009
(954)233-1230 Revision 24:D2/24/2018
SCOPE:
This Evaluation Report is issued under Rule 61G20.3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the a Edition (2017) Florida Building Code sections noted
herein.
6'�TI`EttiO-.P_o yg�ss�too n er' sots
LABELING: Labeling shall he in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED ComPtuiNcii: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nleminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility lodation(s). MEMO etc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code cycle.
AOvEBnsemiiMr. The Evaluation Report number preceded by the words "NEMOietc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then It shall he done in its entirety. '
WsPEcnow Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for Inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 14.
Prepared by:
Robert J.M. Nieminen, P.E.
t_
='E+ �=
•'yp4 p;,.. .b�r The fadmae seal appearingwas autharhed hl'Rohert Nleminen,
\
Florida Registry/on No. 59166, Florida DCA ANE1983
+!,• vo P.E on 01h4f1018. This does not serve as an eiectmnlcally
t,,, "'A �ErA
.
signeddocument*
CERnRCAMON OF INDEPENDENCE:
1. MEMO Ietc. does not have, nor does it Intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMOI etc is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nleminen, P.E. does not have norwill acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being Issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial Interest In any other entity Involved In the approval process of the
product.
5. This Is a building code evaluation. Neither NEMOi etc nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
r
W
W
Z
F
W
0
ME
0
K
d N
C �
3 �
u N
C C
m
E
E
3°
N
L
OE ry t:
C w
a E N
y N
t u 7
0
� c o
°p c
5 0
a
e
n W {Oj
Q 2
8a
�sE
a m�
o
a w c
0 me E
� W C
i
E ° v
ao $ b E E E
V1 6 w Z08
A
N
0 0 0 0 0 .. .O � o m o o o 0 a
a�o�N W�oei �:+`1"1'Ima^0m6rv0m0o WR� SZ",VbV`S
looSoo loay�ooOoB0 'i o111�
oo8.�
ei N M
pWp 444�04444444 �1 0^I�" a�dando���
Ipn V NOI N NN N N4 '�a m00000
�ryv�oov$$iiog"��iog
F aQn0 ❑ OCO ym�4O qq4 cc��O YY4O n !,-6 M m
i�n{�
LL7���Q� �mao=. a;a inadasaaaa� ."i ."i 7-I"7b"tt'�d'S'aai�aan�a
a�. n E"
`ning nnnann �.a n n 2 aaa
aE x a a`� a a a a` a s
(�Eqq a -n�'a '" a S'�.' S''' S'
G7 }i asmmmm aaa o'�.aanaaac5'�ia�i�i a PS'a�aa aaa
yY'�( �^Emp^Ipm 00^gyp p^^mp^m 1m^�n�'p^m^p ponpo 0^w^p nw^�m^ao u���na °�aCe go a$°�S� ppgq S
Z O � lel YI Y1 N N tWil N N Yf N IMif u�1 uWl N N � tO 1W0 t0 � 10 Vi 1�0 �O �O in �o N � iO N
Ab LL 1
09
W
0
F
F
Entity
ERD OW 6049)
ERD (TST 6049)
ERD T}ST 6049)
ERD rW 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TSr 6049)
ERD (TST 6049)
ERD (rSr 6049)
ERD (T5T 6049)
ERD (TST 6049)
ERD (MT 6049)
ERD (TST 6049)
ERD (rST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (f8T 6049)
ERD CW6049)
ERD (TST 60491
ERD (rsr 6049)
ERD (TST 6049)
ERD CM 6049)
ERD (r5T 6049)
ERD (TST 6049)
[CC -ES (EVL 2396)
Miami -Dade (CER 1592)
Po"lan USA
Polyglass USA
Polyglass USA
UL, LLC. (QUA9625)
Examination
Physleal Properties
Physical Pmperties
Physical Properties
Wind Uplift
Physical Properties
Wind Uplift
Wind Uplift
Wind Uplift
Wind Uplift
Wind uplift
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Wind Uplift
Physical Properties
Wind Uplift
Physical Properties
Physical Properties
Physical Properties
IRCCompllance
HVHZ Compliance
Manufacturing Affidavit
PA Affidavit
Materials Affidavit
Quality control
Reference
P40390.08.12-1
P40390.08.12-2
C41420.09.12-3
1339681103.13
P45370.04.13
P3738.02.07-R2
11757.04.01-1-R1
P41630.0&13
P1175L05.03-R1
P1178L11.03-R1
P45270.05.14
6020.07.14-1
6020.09.24-2
6020.09.14-3
6020.09.14-4
6020.09.24-5
602MO9.14-6
P46520.10.14
P43290.10.14
PLYG-SC7550.03.15
P40390.04.15
P44350.10.14-111
PLYG-SCS080.05.15-1
PLYGSC8905.05.16.1
PLYG-SC8080.07.16
PLYG-SC12025.10.16
PLYG-WA3040.12.16
PLYG-5C11900.03.17
PLYG-SC12115.0&17
ESR-1697
NOA 14-0727.08
Products Current
Mule -Hide Cross Ltg
Polystick SA Compound
Service Confirmation
ONEW10jetc.
Date
08/06/2012
08/U7/2012
09/11/2012
03/04/2013
04/26/2013
04/29/2013
04/30/2013
08/D6/2013
IV26/2013
11/26/2013
05/12/2014
09/08/2014
09/09/2014
09/08/2024
09/09/2024
09/08/2014
D9/O8/2014
10/03/2014
10/17/2014
03/24/2015
04/03/2015
05/18/2015
05/20/2025
05/17/2016
07/16/2016
10/12/2016
12/27/2016
03/10/2017
08/08/2017
11/01/2014
01/22/2015
02/28/2009
03/01/2008
08/18/2011
EXp.10/05/2D18
4. PRODUCT DESCRIP IDN:
Nleahaiiically Fasfe*e'dCJntlerlayntet is � :' � • -
4.L3 Elastobase is a fiberglass reinforced, 5B5 modified bitumen base sheet.
4.12 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet
4.1.3 Polyglass 62 Base Is a fiberglass -reinforced, asphaltic base sheet.
4.2.4 PolyglassAPP Base is a fiberglass -reinforced, APP modified bitumen base sheet
q, 2 So}9sA1h0T}n dents. , ;:: _.. . .
4.t2T fro4y3tickT�1I1TS10 Polystickt011�S PWS,,Waanc A'60 mil thick ru alpha} xraterprc0fmg=mem raa€„glass
r-re}nforced, mace wrt Pyn +n}afllm3u ce; meets 17A
4.2.2 Pclystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an
aggregate surface; meets ASTM 131970.
413 PolystickTU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a
polyester fabric surface; meets ASTM D1970 and FRSA/}RI April 2012.
NEMO ETC, LLG Evaluation Report P3206d02A9-R24
Outpate CfAetlmrtnbn 0324Z 6TM EDITION(m17) FBC NON•HVHZ EVALUATION Revldon �. F��28
polygless Root Undedayments; (954) �- Pages of 24
S.
ONEMOletc.
4.2.4 Polystick TU P is a nominal 230-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester
reinforced, with a granular surface; meets FRSA/TRI April 2012.
4.2.5 Polystick TU Max is a nominal 6D-mil thick rubberized asphalt waterproofing membrane with a 190 g/m2 polyester
fabric surface; meets ASTM D1970 and FRSA/TRI April 2022.
4.2.6 Polyflex SAP, Polyflex SAP PH, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) are polyester
reinforced, APP modified bitumen cap sheets; meet FRSA/TRI April 2012.
4.2.7 Polystick Dual Prom Is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyester fabric surface; meets ASTM D1970.
4.2.8 Polystick Tile Pro" is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012.
4.2.9 Polystick MU-X is a nominal 54-mil thick, dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polypropylene film surface; meets AC188 and physical requirements of ASTM D1970 (See Section
5.8).
4.3.2 Mastoflex G TU is a polyester reinforced, modified bitumen tile underlayment composed of a sand -surfaced SBS
modified bitumen back -side and granule -surfaced APP modified bitumen top -side. Elastoflex G TU is for use as an
alternate to Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the 'Single Ply System" from FRSA/TRI April
2012 (04-12) beneath mechanically fastened the roof systems or Hot Asphalt applied "Cap Sheet" in the "Two Ply
System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems.
4.32 Elastoflex S6 G and Elastaflex S6 G FR are polyester reinforced, SBS modified bitumen cap sheets; meet ASTM 06164.
Mastoflex S6 G and Elastoflex S6 G FR are for use as an alternate to "Mineral Surface Roll Roofing' (ASfM D6380,
Class M) In the "Single Ply System' from FRSA/rRI April 2012 (04-12) beneath mechanically fastened tile roof systems.
Elastoflex S6 G Is for use as an alternate to Hot Asphalt applied "Cap Sheet' In the 'Two Ply System" from FRSA/rRI
April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Elastoflex 56 G FR Is for use as an
alternate to Hot Asphalt applied 'Cap Sheet' in the 'Two Ply System" from FRSArM April 2012 (04-12) beneath
mechanically fastened tile roof systems.
4.3.3 PalyNex G and PoWex G FR are polyester reinforced, APP modified bitumen cap sheets, meet ASTM D6222.
Polyflex IS Is for use as an alternate to Heat Applied "Cap Sheee in the 'Two Ply System" from FRSA/TRI April 2012
(0442) beneath mechanically fastened or adhered tile roof systems. Polyflex G FR Is for use as an alternate to Heat
Applied "Cap Sheet" in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened the
roof systems.
LIMITATIONS:
5.1 This is a building code evaluation. Neither NEMOIetc. nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, Is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report Is not for use in the HVHZ
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
S.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product Is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data forthe prepared roof covering..
NEMO M Ur—
M9 Hate "fAufAotlmdWl /3Z4S5
Evaluation Report P32060.02D9-1174
ersEDITON (7017)FBC NON-HVHZFVALUATON F1.5259-R28
PoWjm Roof Undedaymen t; (954) 233-1= Revision 24: 01/24/2018
Page4 of 14
ONEMOletc.
SS Allowable Roof Covers:
•-'.fnBLE� RtioPCovER OlifibrWnu. ':."�.-.
, '•,slats
Underlayinent
AsphaltShlogles
.Nell-Ontlla
Fawn -on Too
Metal
WaadShake'
& shinales
Elaswbase
Yes
Yes
lame Slm N 3-ply rymml
Yes
laaz Shen M 2-ply rrrRm)
Yes
Yes
Yes
ElastohaseP
Yes
Yes
Omtn2ylY.rmm1
Yes
(aeresnmsm2-pfyr, m)
Yes
Yes
Yes
Polyglas G2 Base
No
Yes
l8am sheetlnbpa/sysreml-
Yes
(a®Shen6+bp(y+vnem)
No
No
No
Polyglass APP Base
No
Yes
na= h N2-pt m)
Yes
(e®Samrin2y1v y m)
No
__
No
No
olyitkk.RtTSo'�i MTi P'
Yes
Yes
No %w
11111111my—awill,
I Yes
Yes
PolysUdclR-xe
Yes
No
No
No
Yes
Yes
PolysarkTU P .
No
Yes
Yes (See 5511
No
No
No
Palyslldc TU Plus
Yes
Yes
Yes(see55.1)
Yes
Yes
Yes
PoWckTU Max
No
Yes
Yes(See551)
Yes
No
No
PolystldcDmlPm
Yes
No
No
Yes
Yes
Yes
PoNstickTlle Pro
Yes
Yes
Yes Isee55.1)
Yes
Yes
Yes
Poksti&MU-x
Yes
NO
No
Yes
Yes
Yes
UastoBeu SG
Yes
Yes
Yes (see 5S1)
No
Yes
Yes
ElastolieaSO G FR
Yes
Yez
No
No
Yes
Yes
ElastaRex GTU
Yes
Yes
Yes (See55.1)
No
Yes
Yes
POWMG
Yes
Yes
Yes (See5.5.1)
No
Yes
Yes
Polyff"G FR
Yes
Yes
No
No
Yes
Yes
PalyflexSwor5APFR
Yes
Yes
Yes (SMSS1)
No
Yes
Yes
Mule-NIde SA•M=PSheet
Yes
Yes
Yes 55.1)
No
Yes
Yes
ar SA-APPC pSheet RR1
cs-•I ^Foamtln Tile" is limited to use of the following Approved tile adhesives / underlayment combinations.
Tmik
AILOWADIRMtEAgiIEsNE/17AloERtaYhLBiT.{.OMBINAnbiis's.`" _ • .:
Florida Product Underlayments
Adhesive
Approval
DAP Foam Touch'n Seal StormBond Roof
FL14506
PolystIck TU Plus, PolystickTU Max
Tile Adhesive
DowTlleBondn'
FL22525
PaWckTU P, PoWckTU Plus, Polyflex SAP or Tde Pm
PolystirkTU P, PolystickTU Plus, PoWlck TU Max, PolystickTile Pro,
ICP Adhesives Polysetm AH-160
FL6332
Elastoflex G TU, Elaseoilm S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap I'll,
Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
Polystick TU P, Polystick TU Plus, Polys0ckTU Max, Polystick Tile Pro,
ICP Adhesives Polyseta RTA-1
FL6276
Elastoflex G TU, Elastoflex 55 G, Polou G, Polyflex SAP, Polyflex SA Cap FR,
Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
' Referto Tile Manufacturer's orAdhesNe Manufacturer's Florida PraductApproval for Overturning MomencResis7a EYSluadmlORepoN P17060.0209-R24
NEMO ETC, LLG
[enylmmolAurharalnanea2/5s 6TM EDmON(2027) FBC NON44WZEVAWATiON Revision 24:01J24/208
Potyghm Roof Undedapmelts; (950 233-2230
Page 5 of 24
ONEMOletc.
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck
Polystick (all variations), Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet
(FR) self -adhered to:
➢ New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing
plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed
Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System' Panels
(designed and installed to meet wind loads for project).
Note. Polyglbss does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or
OSB sheathing should be cleaned of all dirt and debris prior to application of Polystirk membranes.
Elastaflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
D ASTM D41 primed structural concrete.
Polyflex G or Polyflex G FR torch -applied to:
D ASTM 041 primed structural concrete.
5.6.2 Bond -to -Insulation:
Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered
to:
D ASTM C1299, Type 11, Gass 1 polyisocyanurate or Type V polylsocyanurate-composite insulation; Dens Deck
DuraGuard; Dens Deck Prime; or SECUROCK Gypsum -Fiber Roof Board.
Elastaflex G TU, Elastoflex S6 G or Elastaflex S6 G FR in hot asphalt to:
D Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
Polyflex G or Polyflex G FRtorchapplied to:
➢ ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, Insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For Installations under foam -on tile
systems, Insulation attachment shall be designed by a quailfied design professional and installed based on testing of
the Insulation/underlayment system In accordance with FBC Section 15043.2.
5.63 Bond to Mechanically Attached Base Laver.
Polystick fall variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or
Tile Pro self -adhered to:
D ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nall Base.
Elastoflex G TU, Elastoflex SG G or Elastaflex S6 G FR in hot asphalt to:
D ASTM D226, Type I or 11 felt; Elastobase; Elastobase P, Mule -Hide Nail Base or Polyglass G2 Base.
Polyflex G or Polyflex 6 FR torch-applled to:
D Elastobase; Elastobase P, Mule -Hide Nail Base, Polyglass G2 Base or Painless APP Base.
For Installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam -an the systems, base layer shall be attached per minimum
requirements of FPSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in
accordance with FBC Section 25043.1.
MEMO ETC, LLC. Evaluation Report P72060.0209-R24
C. fmxeofAvNmlmto-n 455 6TM EUMON(ZM7) FBC NON4IVHZEVALOATION Revision 24: at/uha1R
Pdyglam Roof Uoderlaymerds; (95412aa-1230
Page 6 of 14
ONEMOletc.
5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSAITRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment
forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile. applications. Maximum Design Pressure Is the
result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure
divided by 2 (the 2 to 1 margin of safety per FBC 15049 has already been applied). Refer to FRSA/TRI April 2012 (04-
12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads.
#1 Maximum Design Pressure=-90 psF:
Deck Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer None
Base Ply: (Optional) PolysUck NITS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#2 Maximum Design Pressure=-97.5 ost
Deck: Min. IS/32-inch plywood to meet project requlremems to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional) Polystick MTS or Polystick NITS PLUS, self -adhered.
Underlayment; PoWck TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FRI, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x
W ring shank nails through 32 ga.,1-5/8' diameter tin caps spaced 12-inch o.c.
#3 Maximum Design Pressure =-MS Dsf:
Deck: Min. IS/32-Inch plywood to meet project requirements to satisfaction of Authority Having.lurlsdiction.
Primer: WB-3M0
Base Ply: (Optional) Polystick MTS or PoWck MTS PLUS, self -adhered.
Underlayment Polystick TU P, PolystIck TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x
1W ring shank nails through 32 ga.,1-5/9" diameter tin caps spaced 12-Inch o.c.
#4 Maximum Design Pressure =-135 osf:
Deck: Min.15/324nch plywood to meet project requirements to satisfaction of Authority HavingJurisdiction.
Primer. (Optional) PG300 or ASrM D41
Base Ply: (Optional) Polystick NITS or PoWck MTS PLUS, self -adhered.
Joints: Min. 4-inch wide strips of Elastoflex SA-V overall plywood joints
Underlayment Polystick TU P, Polystick TU Plus, Polystick Tu Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FRI, self -adhered.
#5 Maximum Design Pressu re = -315 Dsf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority HavingJurlsdiction.
Primer. PG300 or ASTM D41
Base Ply: (Optional) Polystick MTS or Polystick NITS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Tile Pro, Polyflex SAP, Polyflex SAP PR, Mule -Hide SA-APP Cap
Sheet and Mule -Hide SA-AP.P Cap Sheet (FR), self -adhered.
#6 Maximum Design
Pressure=-622.5usf:
Deck:
Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer.
PG100 or ASTM D41 '
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt or Polyflex G, torch -applied.
#7 Maximum Design Pressure =_30,0 osf*:
Deck:
Min.15/324nch OSB to meet project requirements to satisfaction of Authority HavingJurisdiction.
Base Sheet
Elastobase or MulrHide Nall Base (poly -film top surface)
Fasteners:
2198, x 1.25-Inch long x 3-Inch head diameter round metal cap nails
Spacing:
64nch o.c. at the 3-Inch wide side laps and 64nch mc. at two (2) equally spaced staggered center rows.
Base Ply:
(Optional) PoWck Mrs or Polystick NITS PLUS, self -adhered.
Underlayment: PoWck TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered. '
Evaluation Report PJMM.CM09-R24
NEMO ETC, LLG
@NJVmre01AuNonmWnAW455
6TM EDmON(2017)FBC NON-HVH2 EVALUATION Rev151on 7A: 01/24/2018
Paly�av Roof Underlayments: (954) 233-IMO
'
Page of 14
ONEMOJetc.
#8 Maximum Design Pressure =-37.5psf':
Deck: Min. 15/324nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base5heet.. Elastobase or Mule -Hide Nall Base(polyflim top surface)
Fasteners: 11 ga. x 1.254nch long 1-inch head diameter round metal cap nails
Spacing: 64nch o.t at the 3-inch wide side laps and 6-1nch o.c at two (2) equally spaced staggered center rows
Base Ply: (Optional) Polystick MTS or Polystitk MTS PLUS, self -adhered.
Underiayment: Polystick TU P, PolystidcTU Plus, Polystkk TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#9 Maximum Design Pressure =-37.5 osf
Deck: Min.19/324nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (2) ortwo (2) layers ASTM D226, Type 11 felt
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-Inch o.a at the 3-Inch wide side hhpsand 12-inch o.c. at two (2) equally spaced staggered center rows.
Undedayment: Elastoflex G TU or Elastoflex S6 G, applied In fug mapping of hot asphalt.
#10 Maximum Design Pressure -43 PO*
Deck: Min.19/32dnrh plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet• One (1) layer ASTM D226, Type II felt
Fasteners: 11 go.x L25-Inchx3/8-Inch head diameter annular ring shank roofing nails at 2-5/8-inch dlametertincaps
Spacing: 4-Inch o.e atthe 2-Inch wide side laps and 4-Inch o.e at two (2) equally spaced staggered center rows
Base Ply: (Optional; for use with self -adhering underlaymem only) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlaymem: Polystick TU P, Polystick TIJ Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered or Elastaflex GTU, applied in full mopping of hot asphalt
#22 Maximum Design Pressure = 45 psf':
Deck: Min.19/32-Inch plywood to meet project requirememsto satisfaction of Authority Having.lurisdictlon..
Base Sheet: Two (2) layers ASTM D226, Type II felt
Fasteners: 11 ga. x 125-Inch longx 3/&4nch head diameter annular ringshank roofing nails at 1-5/8-Inch diameter tin caps
Spacing: 9-Inch o.c. at the 24nch wide side laps and9-Inch o.c. at two (2) equally spaced staggered center rows
Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlaymem: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule-Mde SA-APP Cap Sheet (FRI, seHadhered or Elastollex G'fU or Elastoflex S6 G, applied In full mopping of hot
asphalt
#12 Ma)imum-D-esi�Pressune=•45
Deck:
Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority HavingJurisdiction.
Base Sheet:
Elastobase(sanded top surface for hotasphalt or torcbapplied cap or poly -film surface fortorch-applied cap)
Fasteners:
Simplex MAXX Cap Fasteners
Spacing:
9dnch o.c at the 2-Inch wide side laps and 18-Inch o.c. attwo (2) equally spaced staggered center rows.
Underiayment Elasto8ex G TU or Elaswflex S6 G, applied In full mopping of hot asphalt or Polyflex G, torrhapplied.
#13 Maximum
Design Pressure =-52.50sF.
Deck:
Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase(sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners:
Simplex MAX( Cap Fasteners
Spacing:
9-Inch o.c at the 2-loch wide side laps and 12-inch o.e at two (2) equally spaced staggered center rows.
Undedayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#14 Maximum
Design Pressure=-92.5 Dsf:
Deck.
Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority HavingJurisdiction.
Base Sheet:
Elastohase or Mule -Hide Nall Base(polyfilm top surface)
Fasteners:
Simplex Original Cap Nails
Spacing:
6-Inch ox at the 34nch wide side laps and &Inch o.c at four (4) equally spaced staggered center rows
Base Ply.
(Optional) Polystick Mi5 or Polystick MTS PLUS, self -adhered.
Undedayment Polystidc TU P, Polystick TU Pius, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule-HIde SA-APP Cap Sheet (FR), self -adhered.
NEMO ETC, U.C. Evaluation Report PIMM02.09-1124
Oyttmh qfAW+or&aVMa3245a efDMON(30171 FBC NON4PAREVAWATON neZw'RZB
Polyp Roof Undedaymems; 1854) 233-1230 Revision 24:01/24/2018
Page 8 of 14
fkmoletc.
#15 Maximum Design Pressure =-52.5osf:
Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having.lurisdlcdon. '
Base Sheet: Elastobase(sanded top surface for hotasphait or torch -applied rap or poly -film surface fortorch-applied cap)
Fasteners: Simplex Original Cap Nails
Spacing: 64nch o.& at the 3-inch wide side laps and &Inch o.a at four (4) equally spaced staggered center rows.
Underlayment Elastaflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Powex G, torch -applied.
#16 Maximum Design Pressure =-60 tuf.
Deck: Min.19/32.1nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet Elastobase(sanded top surface for hot -asphalt or torch -applied cep or poly -film surface for torch-applled cap)
Fasteners: 11 ga. x L25Inch long 3/84nch head diameter annular ring shank roofing nails at 1-5/8-Inch diameter tin caps
Spacing: B-Inch o.c at the 4-Inch wide side laps and 8-Inch o,e at three (3) equally spaced staggered center rows.
Underlayment Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt or Polyflex G, torch-applled.
#17 Maximum Desieh Pressure=-60 psF.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot -asphalt or torch -applied sup or poly -film surface for torch -applied rap)
Fasteners: OMG #12 Standard Roofgdp with OMG Flat Bottom Metal Plates
Spacing: 12-inch o.c. atthe 4-Inch wide side laps and 124nch o.m at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elasto8ex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#18 Maximum Design Pressure =-67.5Rsf:
Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underloyment)
Fasteners: 12 ga. x 1.25-Inch long x 3/8-inch head diameterannular ring shank roofing nails at 1-5/8-inch diameter tin raps
Spacing: B-Inch o.e at the 4-Inch wide side laps and 8-inch mc. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastanex 56 G, applied in full mopping of hat asphalt or torch -applied or Polyflex G, torch -
applied.
#19 Maximum Design Pressure =-75 psf:
Deck- Min.15/324neh plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet Polyglass G2 Base or Polyglass APP Base (requires use oftorcfwppiledundedoyment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with
OMG Flat Bottom Plates (AtcuTrac), Tmfast HD with Trufast 34nch Insulation Plates or Simplex MAXX Cap
Fasteners
Spadng: 141nch o.c. at the 4-Inch wide side laps and 104nch o c at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch applied or Polyflex G, torch -
applied.
#20 Maximum Design Pressure--90 ost:
Deck: Min.15/32-Inch plywood to meet project requlremems to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastohase(sanded top surface for hot -asphalt or torch -applied up or poly-Blm surface for torch -applied sup)
Fasteners Simplex MAXX Cap Fasteners
Spacing: 64nrh o.e at the 2-Inch wide side laps and 6-Inch o.c. at two (2) equally spaced staggered center rows.
Uriderlayment: Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt or Polyflex G, torrhappiled.
#21 Maximum Design Pressure--90 osf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet.' Elastobase(sanded top surface for hot -asphalt or torch -applied sup or poly -film surface for torchapplled rap)
Fasteners: OMG #12 Standard Roofgdp or OMG #14 Heavy Duty with OMG 3' Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: & inch o.c. at the 4-inch wide side laps and 6-Inch o.a at three (3) equally spaced staggered center rows
Underiayment Elastc flex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#22 Maximum Design Pressure=-90 osi:
Deek: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sandecipp surface)
Fasteners: Trufast#12 DP orTrufast#14 HD with Tmfast 3' Metal Insulation Plates
Spacing: 6-Inch o.c. at the 41nch wide side laps and 6-Inch o.e at three (3) equally spaced staggered center rows.
Underlayment Elastoflex G TU or Elastaflex S5 G, applied in full mopping of hot asphalt.
NEMO ETC, LLr- Evaluation Report P12060.02.09-1126
Cerh]doteofAuthaimaan 012455 fi'" EDmON(2017) FBC N0N4IVHZEVALUAnoN FL52594M
Pkdyglass ROW Undarlayments, (9541233-1230 Revision 24:02/24/2018
Page 9 of 14
ONEMOletc.
#23 Maximum Desfrm Pressure=-90 osf:
Deck: . Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having.ludsdiction.
Base Sheet Polyglass G2 Base or Polyglass APP Base (requires use of tordrappliedunderloyment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3' Gaivalume Steel Plates, OMG Roofgrip #14 with
OMG Flat Bottom Plates (AccuTrad), Trufast HD with Trufast 34nch Insulation Plates or Simplex MAxlf Cap
Fasteners
Spacing: 94nch ac, at the 44nrh wide side laps and 9-Inch ae at four (4) equally spaced staggered center rows.
Underayment: Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt or torch -applied or Powex G, torch -
applied.
#24 Maximum Design Pressure =-97.5osF
Deck Min. M/32-Inch plywood to meet project requirements to satisfaction of Authority Havinglurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base(pohfilm top surface)
Fasteners: 11 ga. x 1254ndi x 3/8-Inch head diameter annular ring shank roofing nails at 1-5/8-Inch diameter tin raps
Spacing: 4-inch o.c. at the 4-Inch wide side laps and 44neh o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Undedayment: Polystick TU P, Pelystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#25 Maximum Design Pressure=-105 Dsf:
Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet'. Elastobase (sanded top surface for hot-asphaft or torch -applied cap or poly-fli m surfe ce fortorch-applied cap)
Fasteners: Simplex MAJIX Cap fasteners
Spacing: 6-Indr o.c. at the 24nch wide side laps and 6-Inch ac. at three (3) equally spaced staggered censer roars.
Underlayment Elasto8ex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt or Polyflex G, tomh-applied.
#26 Maximum Design Pressure=-112.5 nest
Deck: Min. 19/32-Inch plywood to meet project requirements to satisfaction of Authority Havinglurlsdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga.x1.25-Inchx3/94nch head diameter annular ring shank roofing nails at 1-5/84nch diametertinaps
Spacing: 6-Inch o.c. at the 4-inch wide side laps and 6-Inch o.c. at four (4) equally spaced staggered center rows.
Primer. PG300 or ASIM D41 primer at all tin -caps
Base Ply: Polystick MTS or Polystick NITS PLUS, self -adhered
Underiayment Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Poiyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), selfadhered.
#27 Maximum Design Pressure=.120osf:
Deck Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied rap or poly -film surface fortorchapplied cap)
Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3' Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing. 6-Inch o.c. at the 44nch wide side laps and Finch ci a at five (5) equally spaced staggered center rows.
Undedayment: Elastoflax G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#28 Maximum Design Pressure=-120 osF
Deck: MIn.25/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdidlen.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast912 DP orTrufast #14 HD with Trufast 3' Metal Insulation Plates
Spacing. 6-Inch o.r at the 4-Inch wide side laps and finch o.c. at five (5) equallyspaced staggered center rows.
Underlayment: Elastoflex G TU or Elastaflex S6 G, applied In full mopping of hot asphalt
5.6.4.1 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on the systems carry a Maximum
Design Pressure of-45 psf.
NEMO ETC, LtG Evaluation Report P32060A2.09-R24
ratlJ&vte OfA"Itaa4n 0324115 6�EDMON(2017) FBC 110144WHZCVALLIATION EL525940a
PolyQfass Roof underlaymems7 (954) 233-123O Redidon 24:02/24/2018
Page 20 of 14
ONEMOletc.
5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed
that required under FRSA/rRI April 2012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zane 1 design
pressure determined in accordancewith FBC 1609. In this case, Zones 2 and 3 shallemployan attachment density
designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are
AN51/SPRI WDI, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked
with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January
2016) for Zone 2/3 enhancements.
5.7 Foosure Limitations:
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days
after installation.
Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-days after Installation.
Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Dual Pro, Tile Pro or Elastoflex G TU shall not be left exposed for
longer than 180-days after installation.
Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure
limitation, unless the prepared roof covering Is to be adhesive -set tile, in which case the maximum exposure Is 30
days.
Elastoflex S6 G or Elastoflex S6 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the
prepared roof covering Is to be adhesive -set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum
exposure is 180 days.
5.8 Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226
roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as
set forth In Section 4.3, Note 1 of ASTM D1970-15, should be established as to slip resistance.
5.9 Tile Slippage Limitations (FRSAiTRI April 2012 (04-12))•
When loading roof tiles on the underlayment In direct -deck tile assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
',:�%. .;:Tries::7ne.5ui6wG@JKiry(iratitONswiij0i¢til)k«;piGlNisTnoNs. :r. ,�,:y,.,...: -
c.
Underlayment
'rite Profile
Staging Method
Maximum Slope
Elasmflex G TU
Flat
MtIle stack
-7:22
Lugged
8-tlle stack (6 over 2)
6:12
Elastoflex SS G or S6 G FR
Flat or Lugged
6-tile stack(4over 2)
4:12
PcWck MT5 or MTS PLUS
Fiat
6-tilestack(4over2)
5:12
Lugged -
6-tile stack (4 over 2)
4:12
PolysticcTlle Pro
Flat or Lugged
6-tile stack (4 overt)
7:12
PotystldkTU Max
Flat
&tile stack (4 over 2) or 10-tlle stack
7:12
Lugged
&tile stack (4 over 2)
7:22
Lugged
10-tile stack
6:12
Polystidk7U P
Flat
6-tile stack (4 over 2)
6:22
Lugged
6-tile stack (4 over 2)
4:12
PolystidkN Plus
Flat or Lugged
6-tile stack (4 over 2)
7:12
flator Lugged
ID -tile stack
6:22
Polynex G or PR
Flator Lugged
6-tile stack (4 over 2)
4:12
Polyflax SA P or SA P FR
Rat or Lugged
6-11le stack (4 over 2)
4:12
NEMO Et , LLC. Evaluation Report PIM60.02.09-R24
Oftflmte ofAWim'm0on 932455 6TM EDITION (ZD17)F13C NON-HIHUNALUATION FLM9'RZB
Polyglow RoorUnderhymentsl (954) 233-3230 Revision 24:01/24/2028
Page 12 of 34
ONEMOJetc.
6. INSTALLATDN:
6.1 Polyglass hoof Underleyments shalt be installed in accordance with Polyglass published installation requirements
subject to the limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Elastpbase,flasfobaseP an Base:
6.3.1 Non-TileAoollcations:
Shall be installed in compliance with the codified requirements for ASTM D226, Type If underlayment in FBC Table
1507.L1 for the type of prepared roof covering to be installed.
Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Palystick, Polyflex SAP, Polyflex SA
P FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered, Elastoflex G TU, Elastoflex S6 G or
Elastoflax S6 G FR in hot asphalt or PolyflexISor Polyflex G FR, torch applied. Roof cover limitations are those are
those associated with the top -layer underlayment, as set forth in Table 1,
6.3.2 Tile Applications
Elastobase, Mastobase P or Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the "Two
Ply System" from FRSA/TRI April 2012 (04-22). Reference is made to Table 1 and Section S.6A herein, coupled with
FRSA/TRI April 2012 (04-22) Installation Manual.
y'"sttr'rvMTutS'SP,ti15;iRXCY-•',NF',P�.ius,> r2x,D{a1'gl; Titlefo•or�N1UZC.or-P y#feic`ptyR
nn If+idesnAAPs+�ca2sy� etgiut�Bdesi►AP�r1 -
6.4. Shall be Installed in compliance with the codified requirements for ASfM D1970 (except Polystick TU P) underlayment
In FBC Table 1507.L1 for the type of prepared roof covering to be installed.
6.4.2 Direct -to -Deck with Mechanically Fastened Roof Covers:
All self -adhering materials, with the exception of Polystick Tu Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP
Cap Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage edge seam In accordance with Polyglass / Mule -
Hide back nailing guidelines. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1-Inch
diameter metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back -
.nailed using the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of
membrane. The head lap membrane Is to cover the area being back -nailed.
All seal4ap seams (selvage laps) must be
firmly rolled with a minimum 28 lb. hand
roller to ensure full contact and adhesion.
For Dual Pro and Tile Pro, align the edge of
the top sheet to the end of the glue pattern
(the sheet will overlap the fabric). LM
wmw of Owlap Seam of Dual Pro and Tile Pro
All ovenfabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified
Wet/Dry Cement or Polyglass PG500 Modified Cement applied In between the application of the lap.
Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys,
or exposed roof to wall details
NEMO EM r1C. Evaluatlon Report 1`12060A2-MR24
rerlydmte"fAuVmdmticn 032455 a EDmON 12017) FBC NON4PAUEVAWATION FL9259•1128
Polyglass Roof Underlayments; (9541233-1230 Rmislon 24: 01/2OWHI
Page 12 of 14
ONEMOletc.
Repair of Polystick membranes Is to be accomplished by applying Poiyplus 50 Premium Modified Wet/Dry Cement or
Polyglass PG500 Modified Cement to the area In need of repair, followed by a minimum 6 x 6 inch patch of the
Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be
Installed in water shedding manner. All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a
minimum of 404b weighted -roller or, on steep slopes, use of a stiff broom with approximately 404bs of load applied
for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min. 28lb roller) or small areas of the
roof that are not accessible to a large roller or broom.
6.43 Tile Aoolications [no t allowed for Aolvstick Dual Pro.fR-Xe or Polwdck MUl Xl:
Reference is made to FRSA%TRI April 2012 (04-12) Installation Manual and Table 2 herein, using the instructions
noted above as a guideline.
For mechanically fastened file roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base
Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12),Table 1.
For adh esive-set til e applications, refer to Section SAA herein.
6.4.4 Two (2) Ply Underlavment Systems:
Poh%tick MTS or MTS PLUS followed by Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Tile Pro, MU-X or Polyflex
SAP is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with
the tap -layer material. This Is not a requirement, but Is allowable if a 2-ply underlayment system Is desired.
Polystick MFS or MIS PLUS followed by Polystick TU P, TU Pius, TU Max, Tile Pro or Polyflex SAP Is allowable for use
under foam -on the systems. Limits of use are those associated with the top -layer material. This is not a requirement,
but is allowable if a 2-ply undedaymentsystem Is desired.
6.5.1 Elastoflex G TU, Elastoflex S6 G orElastallex S6 G FR shall be installed In compliance with current Polyglass published
installation requirements. For use In the applications:
✓ Elastoflex 6 TU is for use as an alternate to 'Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single
Ply System' from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet in the "Two Ply System' from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S6 G is for use as an alternate to "Mineral Surface Roll Roofing' (ASTM D6380, Class M) In the "Single Ply
System" from FRSA/M April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied ^Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex SG 6 FR is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single
Ply System' from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet' in the 'Two Ply System' from FRSA/iRI April 2012 (04-12) beneath mechanically fastened tile
roof systems.
6.52 Forhot-asphak-applications,ElastoflexGTU,ElastoflexS6GorElastoflexSSGFRshallbefullyasphaltappliedtothe
substrates noted In Section 5.6. Side laps shall be minimum 3-inch and end -laps minimum 6-Inch wide, off -set
minimum 3 feet from course to course. Side and end laps shall be fully adhered In a complete mopping of hot asphalt
with asphalt extending approximately 3/84nch beyond the lap edge.
6.6.1 Polyflex 6 or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements.
For use in tile applications:
✓ Polyflex G Is for use as an alternate to the Heat Applied "Cap SheeC' Inthe 'Two Ply System" from FRSAjTRI April
2012 (04-12) beneath mechanically fastened or adhered tile roof systems (Base Sheet Limited per 5.63).
✓ Polyflex G FR is for use as an alternate to the Heat Applied 'Cap Sheet' In the 'Two Ply System' from FRSA/TRI
April 2012 (04-12) beneath mechanically fastened the roof systems (Base Sheet limited per 5.6.3).
NEMO ETC, LLG EvalwWon Report P12060.02W.R24
Q"CftCfAUftdZ2dofiAU455 eEDMON(7A17) FBC NG*HVHZEVAUTATION FL5759-R28
P4ggraa Roof urtdcrlaymemr, (964) 233-1730 Revision 24: OIA412018
Page 13 of 14
fkmojetc.
6.6.2 Polyflex G or Polyflex G FR shall be fully torch -applied to the substrates noted In Section 5.6. Side laps shall be
minimum 3-Inch and end -laps minimum 6-Inch wide, off -set minimum 3 feet from course to course. Side and end
laps shall be fully heat -welded and inspected to ensure minimum 3/8-Inch flow of modified compound beyond the lap
edge.
6_7 TileStaein¢:
6.7.2 Tile shall be loaded and staged In a manner that prevents tile slippage and/or damage to the underlayment. Refer to
Table 2 herein, and Polyglass published requirements for tile staging.
6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI Apra 2012 (04-12) must he used
on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or nall-
boards, to prevent the sliding and/or damage to the underlayment during the loading process.
6.7.3 Poiyglass spedfles the minimum cure time after Installation of self -adhering membranes and before loading of
roofing tiles is forty-eight (48) hours.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority H aving Jurisdiction in order to properly evaluate the installation of this product
8. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. 61620-3 CIA requirements. The following
plants have qualified products under their respective physical properties specifications.
.P 'riL::.'
•S'e2tifieatlotiis,'.'t.,n*.i.:%:= _ <0-
Femley, NV, Hazleton, PA & winter Haven,�FI.
ASTM D1970
Polystick MU-x
Hazleton, PA
M-D 13.0004
Elastoflex G TU
Hazleton, PA & winter Haven, FL
ASTM D1970
Polystick lR-Xe
ASTM D2970 & FR_MMI April 2012
Pol ck TU Plus
ASTM D2970 & FRSA/IRI April 2012
Polystick TU Max
Tuscaloosa, AL
ASfM D46M, Tvpe II
PoI lass G2 Base
Winter Haven, FL
ASTM 0226 (physicals) )
Elastobase Elastobase P
ASTM D6509
Polvelass APP Base
FRSA/TRI April 2012
Polystick MTS, Poi stick MTS PLUS
FRSA/TRI APNI 2012
PoI stickTU P
FRSAMI Aprll 2012
Polvflex SAP PolVf1ex SAP FR
ASTM 01970
Polystick Dual Pro
ASTM 03970 & FRSA/TRI April 2012
Polystick Tile Pro
ASTM D6164
Elastoll" S6, Elastofiex 56 G FR
ASTM D6222
PoNflex G, PolVflex G FR
9. QUALITY ASSIJRANcE ENTRY:
UL, LLC—QUA9625; (324) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT-