Loading...
HomeMy WebLinkAboutPRODUCT APPROVALFlorida Building Code Online Page 1 of 5 ADrida "� f;:� Product Approval d pr �� # USER: Public User PmEYtt Anomvai Menu> Prntlptt or APPIIwtIOn searcM1> APPlimtlon tlst> APpllmtiPn Deroll ' FL # FL12192-R6 SCANNED Application Type Revision Code Version 2017 BY Application Status Approved St' Lucie Countf *Approved by DBPR. Approvals by DBPR shall be reviewed and rats d by the POC and/or the Commission if necessary. Comments Archived ❑ Product Manufacturer KAYCAN LTD Address/Phone/Email 1 Memorial Drive Richford, VT 05476 (662) 252-9991 Ext 231 joe.lundine@kpproducts.com Authorized Signature Joe Lundine joe.lundine@kpproducts.com Technical Representative Joe Lundine Address/Phone/Email 402 Boyer St Williston, VT 05495 (662) 252-9991 joe.lundine@kpproducts.com Quality Assurance Representative Joe Lundine Address/Phone/Email 402 Boyer St Williston, VT 05495 (662) 252-9991 joe.lundine@kpproducts.com Category Panel Walls Subcategory Siding Compliance Method Evaluation Report from a Product Evaluation Entity Evaluation Entity ICC Evaluation Service, LLC Quality Assurance Entity Amhltectural Testing, Inc., an Intertek Company Quality Assurance Contract Expiration Date 12/31/2020 Validated By Robert J. Amoruso, P.E. 9 Validation Checklist - Hardcopy Received Certificate of Independence FL12192 R6 COI ICC Certificate of Indeoendence.odf Referenced Standard and Year (of Standard) Standard ASTM D3679 Equivalence of Product Standards Certified By Sections from the Code Year 2011 A.t ATTl0/nF 1 /]rl/1Alo Florida Building Code Online Page 2 of 5 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Go to Page = Method 1 Option C. 12/03/2018 12/03/2018 12/04/2018 0 43 Page 1/ 2 0 0 FL # Model, Number or Name Description 12192.1 Board & Batten Single 7" Vertical Siding Limits of Use Installation Instructions Approved for use In HVHZ: No FL12192 R6 11 Kavcan Installation.odf Approved for use outside HVHZ: Yes Verified By: ICC Evaluation Service, LLC Impact Resistant: N/A Created by Independent Third Party: Design Pressure: +0/-70 Evaluation Reports Other: Design Pressure Rating applicable to negative FL12192 R6 AE ESR-1495.ndf direction only. Installed only on exterior walls over solid sheathing capable of withstanding the design wind loads. Must be installed as per the manufacturers installation Instructions. 12192.2 Center Vented 12°/Solid 12" Triple 4 inch Partially Perforated Soffit Limits of Use Installation Instructions Approved for use In HVHZ: No FL12192 R6 II Kavcan Installatlon.odf Approved for use outside HVHZ: Yes Verified By: ICC Evaluation Service, LLC Impact Resistant: N/A Created by Independent Third Party: Design Pressure:'+0/-70 Evaluation Reports Other: Design Pressure Rating applicable to negative FL12192 R6 AE ESR-1495.odf direction only. Installed only an exterior walls over solid sheathing capable of withstanding the design wind loads. Must be installed as per the manufacturers installation instructions. 12192.3 D-4 Avanti Double 4" Horizontal Dutch Lap Limits of Use Installation Instructions Approved for use in HVHZ: No FL12192 R6 II Kavcan installatlon.odf Approved for use outside HVHZ: Yes Verified By: ICC Evaluation Service, LLC Impact Resistant: N/A Created by Independent Third Party: Design Pressure: +0/-70 Evaluation Reports Other: Design Pressure Rating applicable to negative FL12192 R6 AE ESR-1495mdf direction only. Installed only on exterior walls over solid sheathing capable of withstanding the design wind loads. Must be Installed as per the manufacturers installation Instructions. 12192.4 D-4 Marquis Double 4" Horizontal Limits of Use Installation Instructions Approved for use In HVHZ: No FL12192 R6 If Kavcan Installation. odf Approved for use outside HVHZ: Yes Verified By: ICC Evaluation Service, LLC Impact Resistant: N/A Created by Independent Third Party: Design Pressure: +0/-70 Evaluation Reports Other: Design Pressure Rating applicable to negative FL12192 R6 AE ESR-1495.odf direction only. Installed only on exterior walls over solid sheathing capable of withstanding the design wind loads. Must be Installed as per the manufacturers installation Instructions. 12192.5 D-5 Contessa Double 5" Horizontal Limits of Use Installation Instructions Approved for use in HVHZ: No FL12192 R6 II Kavcan installation.odf Approved for use outside HVHZ: Yes Verified By: ICC Evaluation Service, LLC Impact Resistant: N/A Created by Independent Third Party: Design Pressure: +0/-70 Evaluation Reports Other: Design Pressure Rating applicable to negative FL12192 R6 AE ESR-1495.odf direction only. Installed only on exterior walls over solid sheathing capable of withstanding the design wind loads. Must be Installed as per the manufacturers Installation Instructions. 12192.6 D-5 Elegance Double 5" Horizontal Dutch Lap Limits of Use Installation Instructions Approved for use In HVHZ: No FL12192 R6 11 Kavcan Installatlon.odf Approved for use outside HVHZ: Yes Verified By: ICC Evaluation Service, LLC Impact Resistant: N/A Created by Independent Third Party: Design Pressure: +01-70 1.H..e•//..,,,.,,.+1-4A.k..aA:.,,,...,,/—/— — At1,,......9...,.......—...12L'VV/l.. wT1....1.7A ATTf''0%747 1/annnla f Florida Building Code Online Page I of 5 bP.,N InProductApproval a. USER: Public User ymeucf Aoomval Menu>ymavtt or a,ml ca! on Search > Application t sjj> avPRmHon Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) FL15213-R3 Revision 2017 Approved 17 Plastpro Inc. / Nanya Plastics Corp. 5200 W CENTURY BLVD. LOS ANGELES, CA 90045 (440) 969-9773 Ext 16 rickw@mbidgconsultants.com Vivian Wright rickw@mbidgconsultants.com Scott Johnson 5200 W Century Blvd. Los Angeles, CA 90045 (440) 969-9773 Ext 18 scottjohnson@plastproinc.com Ron O'Connell 5200 W Century Blvd. Los Angeles, CA 90045 (440)969-9773 Ext 16 ronoconnell@plastpro.com Exterior Doors Swinging Exterior Door Assemblies SCANNED BY 5t. Lucie County Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Lyndon F. Schmidt, P.E. PE-43409 National Accreditation and Management Institute 12/31/2019 Ryan 3. King, P.E. .;J Validation Checklist- Hardcopy Received EL15213 R3 COI (b)Certificate of Independenca Dd Standard Year 101/I.S.2 1997 301/I.S.2/NAFS 2002 AAMA/WDMA/CSA101/I.S.2/A440 2005 ASTM E1886 2002 ASTM E1996 2002 ASTM E330 2002 TAS 201, 202, 203 1994 Florida Building Code Online Page 2 of 5 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Go to Page = a Florida Licensed Professional Engineer or Architect Fl i 5213 R3 Eg UIV (a) Enu' ale of Standards odf Method 1 Option D 10/20/2017 10/20/2017 10/24/2017 12/12/2017 G) 4) Page l/20 0 FL # Model, Number or Name Description 15213.1 a. Smooth/Wood Grain/White Wood 68 "Impact" Opaque Fiberglass Single Door- Grain/Rustic/Mahogany Series Inswing/Outswing (X -' Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 II (al lost 15213 1 odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15213.1 for Design Pressure Ratings, any FL15213 R3 AE (a) Eval15213 1 odf additional use limitations, installation Instructions and product Created by Independent Third Party: Yes particulars. 15213.2 b. Smooth[Wood Grain/White Wood 6'e "Impact" Opaque Fiberglass Single Door with Sidelite Grain/Rustic/Mahogany Series utilizing "Snap Frame" Glazing - Inswing/Outswing (OX or XO Fiberglass Door - Configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 II (a) Inst 15213.2.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other. See INST 15213.2 for Design Pressure Ratings, any FL15213 R3 AE (a) Eval15213 2 od additional use limitations, installation Instructions and product Created by Independent Third Party: Yes particulars. 15213.3 c. Smooth/Wood Grain/White Wood 6'B "Impact" Opaque Fiberglass Single Door with Sidelites Grain/Rustic/Mahogany Series utilizing "Snap Frame" Glazing - Inswing/Outswing (OXO - Flberglass Door Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No F IS213 R3 11 !al Tn t 15213 3 df Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes - Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15213.3 for Design Pressure Ratings, any FL15213 R3 AE (al Fval 1 5213 3 odf additional use limitations, Installation instructions and product Created by Independent Third Party: Yes particulars. 15213.4 d. Smooth[Wood Grain/White Wood 6%"Impact" Opaque Fiberglass Single Door with Sidelite Grain/Rustic/Mahogany Series utilizing "Up Lite" Glazing - Inswing/Outswing (OX or XO - Flberglass Door Configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 11 (a) Inst 15213.4.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15213.4 for Design Pressure Ratings, any Fl 15213 R3 AE () E al 15213 4 df additional use limitations, Installation instructions and product Created by Independent Third Party: Yes particulars. 15213.5 e. Smooth/Wood Grain/White Wood 6'8 "Impact" Opaque Fiberglass Single Door with Sidelites Graln/Rustic/Mahogany Series utilizing "Up Ute" Glazing - Inswing/Outswing (OXO - Fiberglass Door Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 11 fat Tnst 15213.5.0df Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes 1lftnc•/hxnxnxr flnri Aahnll Alpo nra/nr/nr ann &I asnv9naram=wCrRVX(lwtDov3vVVKTZ1.__ 12/2R/201 R Florida Building Code Online Page 3 of 5 Design.Pressure: N/A I Evaluation Reports Other: See INST 15213.5 for Design Pressure Ratings, any FL15213 R3 A (a) Eval 15213 5 odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15213.E I. Smooth/wood Grain/White Wood 618 "Impact' Opaque'Flberglass Double Door - Grain/RusticMahogany Series Inswing/Outswing (XX - Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 II (a) Inst 15213.6.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15213.6 for Design Pressure Ratings, any F(1521 R3 A (i) Eval 15213 6 ndf additional use limitations, installation Instructions and product Created by Independent Third Party: Yes particulars. 15213.7 g. Smooth/Wood Grain/White Wood V8 "Impact" Opaque Fiberglass Double Door with Sidelites Grain/Rustic/Mahogany Series utilizing "Snap Frame" Glazing - Inswing/Outswing (OXXO - Fiberglass Door Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FI 15213 R3 II (a) Inst 15213 7 odF Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15213.7 for Design Pressure Ratings, any FI 15213 R3 AE (a) Eval 15213 7 vclf additional use limitations, installation Instructions and product Created by Independent Third Party: Yes particulars. 15213.8 h. Smooth/Wood Grain/White Wood 6'e'Impact' Opaque Fiberglass Double Door with Sidelites Grain/Rustic/Mahogany Series utilizing "Lip Lite" Glazing - Inswing/Outswing (OXXO - Flberglass Door Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 II fa) Inst 15213.8.Ddf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15213.8 for Design Pressure Ratings, any FL15213 R3 AE (a) Eval15213 8 df additional use limitations, Installation instructions and product Created by Independent Third Party: Yes particulars. 15213.9 1. Smooth/Wood Grain/White Wood 5'B "Non -Impact" Glazed Fiberglass Single Door utilizing Grain/Rustic/Mahogany Series "Snap Frame" Glazing - Inswing/Outswing (X - Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: No FI 15213 R3 11 (a) 105t 15213 9 ndf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15213.9 for Design Pressure Ratings, any FI IS213 R3 AE (a) Eyal 15213 9 odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15213.10 7. Smooth/Wood Grain/White Wood 6'B "Non -Impact" Glazed Fiberglass Single Door with Sldelite Grain/RustiUMahogany Series utilizing "Snap Frame" Glazing - Inswing/Outswing (OX or XO Fiberglass Door - Configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 II (a) In t 15213 30 odf .Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15213.10 for Design Pressure Ratings, any FI IS213 R3 AE (a) Eval 15213 10.odf additional use limitations, Installation instructions and product Created by Independent Third Party: Yes particulars. 15213.11 k. Smooth/Wood Grain/White Wood 6'B "Non -Impact" Glazed Fiberglass Single Door with Sidelites Grain/Rustic/Mahogany Series utilizing "Snap Frame" Glazing - Inswing/Outswing (OXO - Fiberglass Door Configuration) Limits of Use Installation Instructions Approved for use In HVHZ: No FI 15213 R3 11 (a) Inst 15213 11 df Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15213.11 for Design Pressure Ratings, any FI 15213 R3 AE (a) E al 15213 11 odf additional use limitations, installation Instructions and product Created by Independent Third Party: Yes , particulars. 15213.12 I. Smooth/Wood Grain/White Wood 6'8 "Non -Impact" Glazed Fiberglass Double Door utilizing 3min/Rusti4Mahogany Series N "Snap Frame' Glazing - Inswing/Outswing (XX - Fiberglass Door Configuration) Florida Building Code Online Page 4 of 5 Limits of Use Installation Instructions Approved for use In HVHZ: No FL15213 R3 II fat Inst 15213 12 odF Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15213.12 for Design Pressure Ratings, any FL15213 R3 AE (a) Eval 15213.12.Ddf additional use limitations, Installation Instructions and product Created by Independent Third Party: Yes particulars. 15213.13 m. Smooth/Wood Grain/White Wood 6'8 "Non -Impact° Glazed Fiberglass Double Door with Grain/Rustic/Mahogany Series N Sidelites utilizing "Snap Frame" Glazing - Inswing/Outswing Fiberglass Door (OXXO - Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FLI 5213 R3 11 (a) Inst 15213.13.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15213.13 for Design Pressure Ratings, any FLIS213 R3 A (a) Eval15 13.13.Ddf additional use limitations, Installation Instmctlons and product Created by Independent Third Parry: Yes particulars. ' 15213.14 n. Smooth/Wood Grain/White Wood 6'8 "Non -Impact" Glazed Fiberglass Single Door utilizing "Lip Grain/Rustic/Mahogany Series N Lite" Glazing - InswIng/Outswing (X - Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use In HVHZ: No Approved for use outside HVHZ: Yes FL15213 R3 II fal Inst 15213.14.od( Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15213.14 for Design Pressure Ratings, any FL15213 R3 AE (a) Eval 15213.14.ndf additional use limitations, installation Instructions and product Created by Independent Third Parry: Yes particulars. 15213.15 o. Smooth/Wood Grain/White Wood 6'8 "Non -Impact" Glazed Fiberglass Single Door with Sidelite Grain/Rustic/Mahogany Series N utilizing "Lip Ute" Glazing - Inswing/Outswing (OX or XO - Fiberglass Door Configurations) Limits of Use Installation Instructions Approved for use In HVHZ: No FL15213 R3 II (a) Inst 15213.15.odf Approved for use outside HVHZ: Yes Verified. By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15213.15 for Design Pressure Ratings, any FLIS213 R3 AE (a) Eval 15213.15.0df additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15213.16 p. Smooth/Wood Grain/White Wood Grain/Rustic/Mahogany Series N 6'8 "Non -Impact" Glazed Fiberglass Single Door with Sidelites utilizing "Up Ute" Glazing = Inswing/Outswing (OXO - Fiberglass Door Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 I. (a) Inst 15213.16 ndf Approved for use outside HVHZ: Yes 'Verlfled By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15213.16 for Design Pressure Ratings, any FL15213 R3 AE (a) Eval 15213.16 ndf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15213.17 q. Smooth/Wood Graln/White Wood 6'8 "Non -Impact" Glazed Fiberglass Double Door utilizing "Up Grain/RustUMahogany Series N Ute" Glazing - Inswing/Outswing (XX - Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use In HVHZ: No Approved for use outside HVHZ: Yes FL15213 R3 11 (a) Inst 15213.17.odf Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15213.17 for Design Pressure Ratings, any FLIS213 R3 AE (a) Eval 15213.17.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15213.18 r. Smooth/Wood Grain/White Wood 6'8 "Non -Impact" Glazed Fiberglass Double Door with Grain/Rustic/Mahogany Series N Sidelites utilizing "Lip Ute" Glazing - Inswing/Outswing Fiberglass Door (OXXO - Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No - FL15213 R3 II (a) Inst 15213.18.od Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: INST 15213.18 for Design Pressure Ratings, any FL15213 R3 AE (a) Eval 15213.18.pdf additional use limitations, Installation instructions and product Created by Independent Third Party: Yes particulars. Art 17/72/7f1IR Florida Building Code Online Page 5 of 5 15213.19 - - s. Smooth/Wood Grain/White Wood 8'0."Impact° Opaque Fiberglass Single Door- G rdin/Rustic/Mahogany Series N Inswing/Outswing (X - Configuration) )Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: No FLIS213 R3 II (a) Inst 15213.19.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Parry: Yes Design Pressure: N/A Evaluation Reports Other: INST 15213.19 for Design Pressure Ratings, any FI 15213 R3 AF (a) F al 15213 19 odF additional use limitations, installation Instructions and product Created by Independent Third Party: Yes particulars. 15213.20 t. Smooth/Wood Grain/White Wood 8'0 "Impact" Opaque Fiberglass Single Door with Sldellte Grain/Rustic/Mahogany Series N utilizing "Snap Frame" Glazing - Inswing/Outswing (OX or XO Fiberglass Door - Configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FI 15213 R3 Il () I st 15213 20 ndf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: INST 15213.20 for Design Pressure Ratings, any FLIS213 R3 AE (a) Eval 15213.20.odf additional use limitations, installation instrucdons and product Created by Independent Third Party: Yes particulars. Go to Page = Back Next a a Page l/20 0 Contact .:: 26018ar Ronr 0.oaE Ta aM1ase R iJ?99 Phone: 850-487-1 BJ4 The State of Hard. Is an Aq/EEO employes Cowr aM 2007-2013 State of norlde :: Pdvaw statement:: AttesslblllN Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your a -mall address released In response to a public -records request, do not send electronic mall to [hls entity. Instead, contact the office by pbo re or by traditional mall. If you have any questions, please contact 850.487.1395. 'Pursuant to section 455.275 (1), Fiords Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalls provided may be used /or official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please pmvlde the Department with an email address which son be made available to the public To determine If you are a limnsee under Chapter 455, F.S., please dick here . product Approval Accepts: W19 99. M "SmurivmE,jucs. plastpro 5200 W. CENTURY BLVD. LOS ANGELES, CA 90045 Smooth / Wood Grain / White Wood Grain Rustic / Mahogany Series Fiberglass Door INSWING / OUTSWING wMracr, GENERAL NOTES I. This product has been evaluated and is in compliance with the 6th Edition (2017) Florida Building Code (FBC) structural mqulremenis excluding the "I igh Velocity Hurricane Zone' (HVF¢(. 2. Pmducl anchors shag be as fisted and spaced as shovm on detols.Anchor embedment to base material shol be beyond wail dressing or stucco. 3. When used In areas requiring wind bome debris protection this product complIes with FBC Sections 1609.1.2 & R3012.12 and does not require an Impact resistant covering. This product meets rintwle level "W end Includes Wind Zone 4 as defined in ASTM E1996 and FBC Sections 1609.122 & R3012.12.1. 4. For 2xsfud framing construction, anchoring of these units shag be the some as thatshovm fm2x buckmasonsy consirucfian. S. Site conditions that deviate from the detaiis of INS drawing require further engineodngamary byaicemedengineermregisteredmchilecl. TABLE OF CONTENTS SHEET# DESCRIPTION 1 Typical elevation. design pressures.& general notes 2 Dow panel delaBs 3 Hoironlalaonsectlem 4 Vedical wss wcflons 5 Buck and (come onchoMg- 2% bx:kmosory construction 6 Frame onchc"-I%buck MOSOn mmWalion 7 Bi of materials & wm onenls 37-W1,11AXO AIDIH 0 �i i � o or o H" 0 Do -' --"��.��- = SWING_ _" .�bVERA(L=� r"s.FRAME_=-- DESLGLJ PRESSURE (PSFJ POS JOG - INSWING 37.50°x 82.00" +65.0 -70.0 ouTSWING 37.50' x 80.37- +65.0 -65.0 N-z E02 IB 12 £ rr N.T.S. °+ _ a en JK m w LFS ; �1T91Qf 2 FL-15213,1 n — o . 79.25 a IO z T FW 2 110119117 UPWE TO 6TM W. 201) MC t}5 1 4/22 19 UPMiE i0 9TN E0. 2014 fHC JK NO DAT — �T" O ao1 a n.w. emwwo coxeursAxry Ixv. Im OOOR PANEL OEMLS T 0 / N4.43409 Br 19, 2077 9: 1.434091ae ��.;�C i BUIMNO-CONSULTANTS. INC. P.O. S.. 230. V.M... G 33595 ph. . N..: 813,659.9197 1-1/,'MIN. 1 2\\\\\ ....... EMS. ITYP.1 4 4 :�0�`' .. •V�� 2 4 12 23 1 1_i e' y. z 30 • � ���•, �� � inn E 16 40 INTERIOR m 3 1B 8W ' O 32 31 EXTERIOR ? m B 21 & eHORIZONTAL CROSS SECTION o 3 o MOM W/IA Wb Ck 3 ^ 14/4'MW. 4 4 1-114'MIN. o z q EMS. (IYP.) EMS. 111'P.) o a 5 6 r CSINK CSMK ----{{ (nP.) PP.) I 6 12 23 23 12 z • 6 9 (3 � y 6� 16 40 INTERIOR INTERIOR 16 as o z 0 0 31 a ove 0211 12 i 5 EXTERIOR EXTERIOR 1S 3 B 21 40 414 1 uHe: N.T.S. 4 oxc. a JK m 1 2 HORIZONTAL CROSS SECTION 1 HORIZONTAL CROSS SECTION o vuc. xo. LFS ; rc ab 3 Wbvrieg slwwn-imveing 3 s� a3wn-hsNng FL-15213.1 0 also aPfxoved s m 3 w 7 ° 6 — A e S '•° �ms ;• 10 5 1A a>o a° o M N Z P P 0 •° P lO = O p • • .iti N a (lYP.J a a 1-1/4°MIN. EMB. (IYP.) • � N • , g � A N • as � tij e �s A �O f1 50 2 H .TI 0 w i5 e. a 1-1/4°MIN. EMB. (TYP.) `4tuu a gryrr / I• Nd.43409 ' October 19, 2017 3 •. tg� T $y g yt PRODUCT; a —mW Wapv oy. i - . 4 B h Lyndon F. S.hmldt %ilc •• •F:��t'•' • �� A N E 9 Z N FIBERGLASS P�PRC) INC DOOR P.E No. 4]s09 NAL4�,. PART OR ASSEMBLY: J 4 BUILDING"GONSULTANIS. INC. v 1" ro VUMCAL CROSS SECTIONS UV P.O. eoe MO. Valnm, r W595 EVISIO 5 PM1vne N., 813.659.9197 FT3PE CA Nv. 9813 O zerz w.w. ew�ewv evueuvuee run_ 3 t0 19 1] UPBATE 10 6Bi Ee. 301> i13G LFS 1 9 T i3 UPOAIE ie S1N E0. (TOH F9G JN NO GATE" - B1' TYP. HEAD & JAMBS 2X - BUCK MASONRYI Q OPENING z 0 LED BUCKANCHORING HfNGEJAMB CONCRETEANrHOR NO 1. Concrete an&IDCGIMW of the comers maybe acrjusted to maIntoln the min. edge d1slance to mutorldinis. 2. Concrete anchoriccations noted as'MAX. ON CEWER'mwt be acausted to maintain the rain. edge cr4ance, to mortwjofnfs, adcriffonal concrete anchors maybe required to ensure the "MAX. ON CENIEW` offmanslon are not exceeded. 3. Concrete anchor table: .. ri . .TYPE . E 2e -ADACE JTW 4" TA ON® ELCO 4" WRACON WOOD SCREW INSTAULAITON NOTES: id crafance, & to O.C. spacing of T.Tnt.ln 1 1. itmurn 518, edge distance. I ., ,,odscrem to prevent the spatting of "ad. 2x BUCK FRAME MASONRY OPENING '. HEAD & JAMBS FRAMEANCHORING Masonry 2XbUckwmWctlon HINGEJAMB SWrEJAMB STRIKEPLAMDETAIL LFL— 1521 Ead, 1 3D TYP. HERO e, JAMBS Ix BUCK MASONRY OPENING _ i O �e HINGE JAMB FRAMEANCHORING Masonry Ix buck construclion CONCRETEANCHOR NOTES: 1. Concrete anchorloculiom of The comers may be 007usted to molntafn the rNn. edge distance tomodar/oink. I Concrete anchorlomlions noted ar "MAX ON CENTER'must be adjusted to maintain the min. edge d9tonce to modarJaints• additional concrete anchors maybe requled to ensure the WAX ON CENTER'dimenslan on, not esceeded. B. Concrete anchorfobfe: fANCN(yRANGHOH ? MINr �, •' MIN.CLEARANCE MIN.GLEARANtE, ' TYPESIZE 'EMBEDMENT i0 A1g30NRY TOAOJAC(NT ' SEDGE ANCHOR` AITW IfW m 1/4' 1-1/4' 2' 4' ELCO ULTRACON 1/4" 1-1/4" 1" 4' Ins m 3/16' 1.1/4' S' 1-1/r TAPCON WOOD SCREW INSiAL1ADON NOTES: Maintain a minimum 5 B'etl a tlRlance, I' entl distance, & 1°o.c, spacing of 'I I. g woad screws to prevent the spBHNg of wood. STRIKE JAMB HINGEJAMB STRIKE PLATE DETAIL JJYii i * ==-w+P •fT4W`g� n •........ him Tnt all a FFF�, R g g @w �6N71 r mM1n� \• mD� i! A-0 i c 02116112 _ ,u N.T.S. s. e: JK i e LFS s Ima xw u FL-15213.1 � a S all: BILL OF MATERIALS ITEM DESCRIPTION MATERIAL I MASONRY -3.ODO PSI MIN. CONCRETE CONFORMING TO ACI 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE 2 1X BUCK SG>=0.55 WOOD 3 2XBUCKSG>=0.55 WOOD 4 1/4" MAX. SHIM SPACE 5 1/4" X 2-3/4" PFH ELCO OR ITW CONCRETE SCREW STEEL 6 4110x2-1/2'PFH WOOD SCREW 1.15'MIN. EMBEDMEKTI STEEL 8 09x3/4" PFH WOOD SCREW STEEL 9 DOOR SKIN MIN. 0.075' THICK FIBERGLASS 10 INSWING VINYL DOOR BOTTOM SWEEP BY ENDURA VINYL TOA VINYL DOOR BOTTOM SWEEP #362 BBY HOLM IND. VINYL I REINFORCEMENT WOOD FOR LOCK WOOD 12 FINGER JOINTED PINE JAMB WOOD 13 #9x2.1/4"PF ODSCREW STEEL 14 BOTTOM RAIL CELLULAR PVC 15 INSWING ADJUSTABLE THRESHOLD BY ENDURA ALUM. / WOOD 15A INSWING ADJUSTABLE ALUMINUM THRESHOLD BY DLP ALUM./WOOD 16 FORCE5WEATHER STRIPPING BY ENDURA FOAM I6A COMPRESSION WEATHER STRIP QLON 650 BY SCHLI: EM FOAM 17 KWIKSETKEYFD ENTRY-SIGNANRESERIES STEEL 18 KWIKSET DEADBOLT- SIGNATURE SERIES I/5UJ STD 0 POLYURETHANE FOAM BY NANYA POLYURETHANE TF 4"x4"BUTT HINGE STEEL 23 POLYFIBERJAMB COMP./VINYL 24 HINGE&LATCH STILE CELLULAR PVC 25 TOP RAIL CELLULAR PVC 26 DEADBOLT STRIKE PLATE STEEL 27 LATCH STRIKE PLATE STEEL 28 0 TSWING BUMPTHRFSHOLD ALUM./WOOD 29 HINGE & LATCH STILE REINFORCEMENT LVL 30 1 /4" X 3-3/4" PFH ITW CONCRETE SCREW STEEL 31 #9 x 1"PFH WOOD SCREW STEEL 32 1/4" x 3-1 4' PFH UW CONCRETE SCREW DEL 93 3116"13I/4°PFH IPNCONCRETESCREW STD 40 DOOR PANEL -SEE DOORPANEL DETAIL SHEET FOR CONSTRUCTION DETAILS n �-y F-- 4.56' I I LEMP2 .-1-T 1 - 2.43' I2 JAMB ISA AOJUSIABIE INSWIN ILL N I-� 456" I-- 2.47 23 OYFlBERJAMB rFjry1 4.56" 28 01L19N7NG SUMP 7NRESHOLO W. FL-15213.1