Loading...
HomeMy WebLinkAboutBUILDING SITE PLANS, — — — — — — — — — — — — — — — — — — — — — — — — — — — FND 4"x4" CM --- ------------------------------------------------- x FND 4"X4" CM PRIA LS 2391 PRM LS 2391 0.04' S, 0.06' W 0.02' W I LjJ l I DRIVEWAY �r­ PRDPOSED 10 /'_WATER SERVICE EXISTING POND 1 5 57�33 PROPOSED WELL 1 691.56' L0 x 4D ICD I LOT 7 lu� VACANT IN 0 (U x x VACANT PASTURE C14 0-- 180.00, ItV P r1 -- ----- 1050 GAL. SEPTIC TANK (1b 0 0 M0 I ", x x 0 I � FILE COPti� _/ -------------------------------------------- ---------------------------- x 01 xq; 0' D.U.E. — — — — — — 10' — — — — — — — — — — — — — — D.U.E. S89*28'28"W — — — — — — — — — — — — 929.83' — — — — -- — — — — — — — — — — — — — — — — — -- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — - 11, BENCHMARK SET 5/8-IR&C 500 S.F. DRAINFIEL LB 4286 (44) QUICK4 INFILTRATORS FDOH in St. Lucie County 750 S.F. I \-SET 5/8"IR&C UNOBSTRUCTED AREA Environmental Health LOT 6 LB 4286 Site Plan Approved for Construction VACANT Supersedes All Previous Site Plans for OSTDS#5-6-SI5-1 tllz-'.f & Well #5`)-2 Date: Revie er. NOTES: 1) Not valid without the signature and the original raised seal of a Florida LEGAL DE�c_-;CRIPTION Licensed Surveyor and Mapper. 2) Description shown hereon provided by the client and/or their agent. LOT 7, ACCORDING TO THE PLAT OF DRAWDY/BROCKSMITH ROAD SUBDIVISION, 3) The last date of field work was October 18, 2017. AS RECORDED IN PLAT' BOOK 75, PAGE 23, PUBLIC RECORDS OF ST. LUCIE 4) Overall parcel contains 5.01 Acres, more or -less. COUNTY, FLORIDA. 5) Lands shown hereon were not abstracted by this office for right —of— LEGEND ways, Reservations, Agreements, and/or Easements of Record. Such CONTAINING 5.01 ACRES, MORE OR LESS. information should be obtained and confirmed by others through FIND DENOTES FOUND appropriate title verification, LB DENOTES LICENSED BUSINESS 6) Bearings shown hereon are relative to the East right—of—way fine of OE DENOTES OVERHEAD ELECTRIC Brocksmith Road having a bearing of N00'02'02"W. D.U.E. DENOTES DRAINAGE & UTILITY EASEMENT 7) Underground utilities, utility services, foundations and improvements PILS DENOTES PROFESSIONAL LAND SURVEYOR were not located as a part of this survey. CM DENOTES CONCRETE MONUMENT 8) Flood Note: By graphic plotting only, this property is In Flood Zone IR&C DENOTES 5/8"IRON ROD & CAP "X", according to the Flood Insurance Rate Map, Community Panel O.R.B. DENOTES OFFICIAL RECORDS BOOK No.12111CO165 J and an effective date of February 16, 2012. No DENOTES PLUS OR MINUS additional search of the public records has been performed. There may No. DENOTES NUMBER be additional map amendments affecting this property. PRM DENOTES PERMANENT REFERENCE MONUMENT 9) Additions or deletions to survey maps or reports by other than the DENOTES WOOD POWER POLE signing party or parties Is prohibited without written consent of the DENOTES signing party or parties. GUY ANCHOR LB DENOTES LICENSED BUSINESS ROWRTfIqi:jnHW I '-` , 'E'YOR,& MAPPER -__ Nd. 6540 SIGNATURE DATE CULPEPF)ER & TERPENING, INC CONSULTING ENGINEERS I LAND SURVEYORS 2980 SOUTH 25Lh STREET * FORT PIERCE, FLORIDA 34981 PHONE 772-464-3537 - FAX 772-464-9497 - v xt-engxom 151 SW FLAGLER AVENUE I STUART, FLORIDA 34994 PHONE 772-220-3376 . FAX 772-464-9497 * w xt-engxom STATE OF FLORIDA CERTIFICATION N. LB 4286 -REVI S I O N S- By I DATE ADD .,WATER, SERYI C.E.. ....... ...................... .......................................... ..................... ..................................... C.O.N.E.CTI.VITY... ..... .. ... I ..................... ..... ............ ..... ....... ....... I ...... ....... ........ ......... ................ ....... I ....... . 1—— ... 11 ... I' ... RNJ.. ......... 11 ..... I .............. ...................... , .111P/19. ............ ....... BY DATE FIELD .... 1 ................................ CALCS. .... ... ........ DRAWN OF 12-17-18 .... ............ ... ..... ...... DETAILED CHECKED APPROVED SEPTIC SYSTEM PLOT PLAN PREPARED FOR CHRIS DAY ftj� ()boq DATE: 12-17-2018 HORIZ. SCALE:1"=40' VERT. SCALE: N\A JOB No. 18-121 [SHEET I OF 70'-0" 24'-0" 12'-8" 24'-0" 9'4" 9'-6" T-I1" 4'-3" 3'-10" 4'-4" l'-4" 3'-2" 5'-9" T-10" 3'-10" 4'-9" 1'-4" 4'-11" 4'-5" 25 s.h. L-1 25 s.h. L-1 Egress Egress 0 o 0 0 00 0 4' 0" 4' 8" 4" 14'-0" o 0 °° ------------- -- ------ ----M L'-7 In U O ter° Master Bdrm. L-1 ❑ 25 s.h. 25 L-1 s.h.❑ i i Porch u" L-6 ❑ 0 o 0 O CI ' ' 0 9'-4" Ceiling = 9' 4" Cing. ~ from FFE — ~ 8" 3' 0" 5' Cafe Q L-2 � 00 Header at 96" 9'-4" Ceiling o � m C� �:. u �° L-1 L-1 25 25 L-1 Tem . Glass pp �� s on 42" Tall s.h. s.h. s.h. H34 O [] L-5 •• 0 O s.h. 2680 M s:. Wall ` O O 2680 o Pocket ~ Header I p Ot 4' 4,� 3, 3„ 11'-5"JN5'-4" Y. 8�� 1 1 at 96" 4 7�_ 5'_0,� I 20'-0" 1:1'-0" O L-1 36" x 72" Tub Unit _ o0 _ 9'-4" Cing. I B drm 2 25 s.h. . Glass ZL i i I Ic 9'-4" Ceiling ____� d.w. Family 0 3'-6" 25 s.h. HB Td 2880 co i i I 11'-4" Ceiling o E ress g L-1 Lnd. 4�, o tib a ❑ Clrl g Range & h Exh. Hood r P. VTR � i� � � N 112" 5'-8" 12" ^ m Q 9 4 ❑ Cing. i 11 it r; Header • ❑ e � Kitchen i i at 96" ❑ 1 Header o L-2 4 9'-4" Ceiling at 96" Oo r o Wall Ref�ater `n 2080 H34 s.h. SafeL NU Oven Header -- �O o 0 Glass Bollard R11 batt insul. at 96" ne —__= N F. ti� 2880 _—_ in adj. walls Pocket ❑ 9'_4" « 9'-4" 9'-4" 3'-8" 1'-6" 3 0" Cing.�0 2680 Cing. 11 2880 13'-0" 12' 12'-0" N T-8" 2'-0" 8.4" I'-8" 3'-6" 5'-6" H34 f-----------1 Header i i O ❑ s.h. at 96" 1 1 lt-----------� N Dining it O 22.5 x 54 Attic N Bdrm. 4 LQL Access with ~ 9 -4' Ceiling Ladder 9'-4" Ceiling ~ HB O [V \p N Q L-3I N 00 00 L-4 3080 Dr. L-L L-1 d and (2) 12" ImpactSide tib� 1 Lites � 25 ( 2❑2 Egress Egress 0 L-1 a s.h. s,h. 18,E 23'_8„ 8" E. ° I9'-4" Bdrm. RY Garage L-1 Ceiling from FFE 9'-4" Ceiling ❑ O -- - --- ---- --- ------- -------- --- -------------- - --- - _ = 9'4" Ceiling ° ° _ ° ° ° v from FFE -- -------------- ---- --- L-9 --- ------ --- -------------- L 9 --- -- 81i 1T_0" 8, 0 0 Ell 25 0 M ir, L-1 s.h. El IMF=lil L-1 h ❑ O 0 25 Egress L-1 s. 5'-9" 5'-9" 6-9" 6-9" 1'-8" T-5" 1 4'_2" T-5" 1'-8" 3'-6" 3'-6" 1'-8" T-5" 1 4'_2" 1 2'-5" 1 P-8" 11'-6" 13'-6" 12'-4" T-0" 12'-4" 25'_0" 31'-8" 13'-4" Floor Plan Scale: 1/4" = 1'-0" Project Data Project Name: Day Residence Street Address: T.B.D. City: Ft. Pierce County: St. Lucie State: Florida Scope of Work Design Loads Roof Live Load: 30.0 p.s.f. Wind Speed: 160 MPH Wind Importance Factor: 1.0 Building Category: R Wind Exposure: C Internal Pressure Coefficent:.18 Structure Designed: Enclosed Soil bearing capacity: 2000 p.s.f. New One level CBS Single Family residence Area Tabulation Building Code Living: 2656Garage: 625 2017 Florida Building Code: Residential Porch: 267 20++? ational Electrical Code: NFPA 70 Entry: 213 Bulldlna Data Occupancy Type: Group R Construction Type: V Number of Stories: One Project Area: 3746 s.f. Total: 3761 Total Cubic Volume: 25,726.4 Climatic & Geographic Design Criteria Weathering: Negligible Termite Area: Very Heavy Flame Spread Index & Smoke Developed Index Insulation Flame Spread: Not to exceed 25 Insulation Smoke Developed Index: Not to exceed 450 Wall Finishes: Not greater than 200 Ceiling Finishes: Not greater than 200 Spray Foam Insulation- 9'-4" *- T.O.B. --- 1/2" d.w. 1 x 4 p.t. Firestop Two Course Perimeter Beam with (1) #5 Rebar in each course, Filled with Grout 1 x 2 p.t. furring strips 24"o.c. —, with R4.1 Foil insulation 1/2" d. #5 vert. rebar in grout filled cell See Floor Plan for Locations 4" 3000# Fibermix Cone. on .006 Vapor Bearier on Clean, Compacted, Termite Treated Fill —\ F.F.E. ` (2) #5 Rebar 5V Metal Panels over 30# Felt on 19/32" c.d.x. plywood fastened as per nailing schedule Pre Engineered Wood Roof Trusses 24"o.c. Shop Drawings by Others See Connector Schedule 12 Galy. Drip Edge Varies over 1 x 3 p.t. U F--•i °O � M Q W v U c� a bQ 00 00 Q� CJ o w j U a W � � a d- > Ct U Uoz� � CIS pp M I�1 W � 2 x 8 R.S. Pine W Fascia Board U z P-6" Stucco Soffit Over High Ribbed Wire Q (, Lath w Install one layer of 15# d! felt to framing prior to W ,� installing wire lath 8x16x8 U /- CMU Typ. a/ W Light Textured CJ Stucco Finish ,� ^ Lap Siding Look w F—I Qn Stucco Pattern on Front Elevation W 6 1/2" Exposure -a L7 z #5 Vert. Rebar with 10" Hook and 30" Lap. Tie to Vert. Rebar In Cells z I Grade ~ Typical Wall Section drawn 0. checked s.l. date 1123119 scale as noted job number 18058 sheet A-1 0 M N a vn v co 70'-0" 24'-0" 12� 8�� ?A'-O" 9,4' 5'-0" 4'-8" 3'-10" 5'-8" 4'-10" 2'-4" 3'-10" 3'-10" T-5" 3 V-4" 6-10" 4'-0" 3'-10" 3'-10" T-10" 1'4" T-9" 4'-0" T-7" m m F-1 Ld I] ME F- - - - - - --------------------� 1 28" x 28" x 18" Pad Ftng. withI28"x2"xIS I F-I 1 o r om F-1 m —_ ❑Or------- F 3 (1)#Srebar6"o.c. I I----� ---- ---- ---- --- -- Each Wal i F-1i F-� I F13 Ell I o N I m m F-1 m E m l i m m m m F-1 m L------------------ — — — 36" x 36" x 18" I F-1 Pad Ftng. with 4" I (1) #5 rebar 6"o.c. I o o I I 1 _ Each Wal I al F12 I I I o f IF-2 I l 0 I 1 2'- „ 11'-6" 5'-4" 12'-2" 5'-10" 1 4, I F-3 I ❑ i _______ 10121 LEMF-2 0 0 F-3 nr3 m(I l 0 o I I l i Verify Tub Drain I I I i Location with I I I Mfg. Specs. I I 4 I I F-1 1 ❑ t,�'_--' I L------=-J I I I m II I I II � I I I ❑ I I II I 0 I I F-11 N I I 4" 3000# FIBERMIX CONC. 1 1 OVER .006 VAPOR BARRIER ON CLEAN, COMPACTED, ❑ I TERMITE TREATED FILL I 1 m t-------------F3 ----------- --� 1 ASSUMED F.F.E. 0.00' I I FJ3 I. F0 L O 1 j 11ir 1 I m 8 22'-6" I 1 I 1 I I 1 I 1 Slope 2" 4" I F�3 I 1 1 Slope for I 36" x 36" x 18" — — — — — — — — — — — — Gara e Dr. g I Pad Ftn with (1) #5 r bar 6"o.c. I m F-2 O O I I EM I Each Wal I I I I _ I L M 4" F-2L---- j F-1 N -- ----- F-2 F-2 ---_-- r —, 7 28" x 28" x 18" 1 1 I p i p ••------IF-2 p O [7 O .. p Pad Fing. with 1 I I I n I (1) #5 rebar 6"o.c. I O 14" I I I o I L — Each Wal cJ 12" I 1 8„ I F-21 1 n oi FLI4 1--- I ------ --5- - -- 1 1 ❑ Fro =-----rF 5 F 0_ - - - - - - F--------� 1 I I F14 I F-1 I I m o m m L---------- --d L-------------I Concrete Steps `"' F-1 m 0 m 4'-10" m 1'-8" 4'-0" 4'-0" 12'_4" tl 1'_8" 1'-8" 4'-0" T-0" 4'-0" 1214" o P111'_8" 4'-9" 3'-10" 0 m 4'_9" 3'-10" Y-10" 3'-10" 4'-10" 3'-10" 11'-6" 13'_6" 25'-0" 31'-8" 13'_4" T Foundation & Footing Plan Scale: 1/4" = F-0" SOIL STATEMENT: Foundation has been designed for a soil bearing capacity of 2000 p.s.i. Fill shall be laid in layers of 6". Each layer to be compacted to 95% compaction. If the contractor encounters, while digging the foundation, any discrepancy to suggest the soil may be inadecuate, he must immediately report it to the owner and the Architect or Engineer so as to order a soil boring test. Dowel Rod Repair Note In the event vertical steel has been omitted from the down pour locations, drill 5" into concrete (no closer than 3 3/4" from edges and 5" from ends of cap walls) Remove dust per manufacturers instructions and use Two part epoxy to anchor the #5 rebar in place. Use either "Hill C-100" or Simpson Epoxy -Tie. 0 0 h �n N in N �n cn F-1 F-3 18" x 18" mono. footing 8" x 8" thick edge with (2) #5 rebar cont. with (1) #5 rebar con. 4" 4" 4" �- - 18" 4"_ f 8, 18" MONO. EDGE FOOTING EDGE FOOTING F-2 F-4 18" x 18" mono. footing with (2) #5 rebar cons. 18" x 18" mono. footing with (2) #5 rebar coot. 8° 4 4" 4„ slope 4" 14' 14 18" 18" STEP FOOTING CURB FOOTING Typ. Nosing 10" 11 Typ, Cast In Place cone. Steps with 3000# mix F.F.E. _ Riser Hght, not to exceed 7 3/4" NZ IN #5 Rebar 12"o.c. \ 25" #5 Rebar \ �'� 80 TYp Driveway Conc. Step Detail Entry '00.0 _0- F=E F._ - M - cr I FORMWORK & SHORING No structural concrete shall be stripped until it has reached at least 80% of the 28 day design strength. Design, Erection, & Removal of all formwork, shores, & reshores shall meet the ACI Standards 347 and 301 Contractor to verify all building setbacks prior to the start of construction. A formboard survey shall be submitted to the building department for approval prior to pouring concrete. (2) #5 Top (2) #5 Middle (2) #5 Bottom - — - -4" #3 Vert. 16"o,e. n it it •I I I Grade II II _25" n u It u \ II II N 12" F-S GENERAL FOUNDATION NOTES Concrete shall be a minimum of 4" thick over clean, compacted, termite treated fill and 6 mil polyethylene vapor barrier. If concrete slab contains 6" x 6" 10/10 WWM provide 1" coverage Concrete shall have at minimum compressive strength of not less than 3,000 p.s.i. All 90% hooks are to be extended 10" minimum beyond the turn. Field bends are to be done cold and the diameter of the bend, measured on the inside of the bar, is not to be less than six bar diameters. Minimum coverage for rebar shall be 3" in footings and 1 1/2" in bond beams. Hooks may be rotated horizonitally if required to achieve minimum coverages. Rebar overlap shall be 48 bar diameters. 30" for #5 rebar The foundation design assumes that the soil has a minimum load carrying capacity of 2000 p.s.f. In the event the soil bearing capacity falls below 2000 p.s.f. This foundation plan may be superceded by Foundation Design Engineer. Satisfactory compaction test of fill does not verify lower soils are adequate. All specifications and dimensions to be verified by contractor. All exterior slabs shall slope a minimum 1/8" per foot for drainage U 1-1 � 0 W � � z v bjb . ,_4 W W ago N v cV W Q U � H C Cn o W U C7 O 44 L ^W�l _) U r> �j Ir O U Qz 00 M U z W Q � 7a C� U U M drawn S.I. checked s.1. date 1/23119 scale as noted job number 1805E sheet A-2 Scare: 1/4 - r -U 211 +33.5 +33.5 +33.5 +33.5 36.3 36.3 36.3 -36.3 Rear Elevation Scale: 1/4" = V-0" 27" x 27" "Blacked +33.5 +33.5 +33s -36.3 -36.3 -44.s Two Coat Stucco over CBS block Product Approval Affidavit Form Category Subcategory Approval Numbers Manufacturer Model Number Trlase yP Attachment Method Building Design Pressures Product Rated Design Pressures EXTERIOR DOORS Swinging FL#: 17184.17 Plastpro Fiberglass Impact Head & Sill: 6" from corners. Jambs: 6" from corners and 14"o.c. max. Use 1/4" dia. Tapcons with 1 1/4" embedment in concrete +33.5 -36.3 +50.0 -55.0 Swinging (French) FL#: 17184.2 Plastpro Fiberglass Impact Head: 4" from corners & 5" & 9" from center. Jambs: 4" from corners and 18.5"o.c. max. Use 1/4" dia. Tapcons with 1 1/4" embedment in concrete +33.5 -36.3 +50.0 -55.0 Garage Overhead FL#: 15371.2 DAB Door Company p y Hurricane Master 824/811 N A Flag Bracket Angle (3) total 5/16" x 1 518" lag screws. (7) total Bracket 7-0" height (1) 5/16" x 1 5/9" lag screws per bracket. +27 9 -31.2 +36.0 -44.0 WINDOWS Singlehung FL#: 239.7 PGT 5500 Impact Head & Sill: 6" from corners and 15"o.c. Jambs: 6" from corners and 14" o.c. Max. 4" from meeting rail. Use 3/16" Tapcon with 1 114" embed, into concrete +33.5 -44.9 +50 / -50 Fixed FL#: 243.10 PGT 5540 Impact Head & Sill: 6" from comers and 8"o.c. Jambs: 6" from corners and 8" o.c. Use 3/16" Tapcon with 1 3/4" embeded into concrete +33.5 -36.3 +/- 70.0 ROOFING PRODUCTS 5 V Crimp Roofing FL#: 17443.1 JA Taylor 5 V Crimp #9-15 or #10-14 x 2" Long wood screw with washer at each Rib 16"o.c. -57.5 -69.25 Underlayment FL#: 9777.7 Owens Corning Speeciaallty Direct Attachent to plywood SIDING FL#: 13192.2 James Hardie Hardie Plank Fasteners shall be ET&F block nail .30 Head dia..14 Shank dia. and 1 1/4" long. 21 "o.c. malt. -50.0 -92.0 +33.5 36.3 .tr. t --0- lsa-o'." god 1. icals corative Corbett ,le to be Selected - - - - T.O_B 914" Window Head _ -0- 8' 0" x 8 Trim hive Header o be Selected Connector Schedule Truss Bearing Truss Connector QntY Connector Fasteners Point Uplift ID Uplift (2) 34' ATR Drill & B03 9 6790 HGT-3 1 10,530# Epoxy with 12" min. Embed. & (16) 10d 3 Ply 16 4506 to Truss 16 4352 Drill& (2)o3/4"with CO3 HGT-3 1 10,530# 12" min. 9 6359 3 My Embed. & (16) 1Od to Truss (1) 5/8" ATR Drill & 6 3219 MGT 1 3,965# Epoxy with 12" min. D04 Embed. & (22) IOd 2 my to Truss 10 2300 RETA20 2 2,500# (6) 16d per strap All trusses Each <1910 HETA20 1 1810# (9) 10d x 1 1/2" to CBS Bring. <1810 HETA20 1 1810# 1 (9) 10d x 1 1/2" All trusses Each <1000 MTS18 1 1000# (9) 10d x 1 1/2" to Frame Brng. <1000 MTS18 1 1000# (9) 10d x 1 1/2" Valley Supporting Framing (4) lOd Trusses <250# VTCR 1 370# valley Truss (3) lOd x 1 1/2" Connector Notes: Do not substitute connectors Do not sheath trusses before all straps are in place Attach valley trusses and piggy back trusses, if present, to main trusses per truss manufacturer drawing. Truss to truss connection by truss company, installed F.F.E. per manufacturers specs. I x 4 Corner Lateral forces perpendicular and parallel to wall has been Trim considered (less than 300 p.l.f.) Non Impact mutters Two Coat Stucco Finish over paper backed wire lath over House Wrap over 19/32" c.d.x. plywood fastened as per Nailing Schedule 2" v.t.r. 1 1 Plumbing contractor to provide a water hammer & shut off valve at each fixture Insulate all hot water lines Plumbing Riser Diagram Cast Crete Lintel Schedule Contractor to approve temporary bracing to prevent toppling of trusses, see HIB-9. Other specs, if different from above, have priority. A.T.R. = All Treaded Rod Drill and Epoxy Set all A.T.R. Use either "Hilti" C-100 or Simpson Epoxy Tie Epoxy Provide equal number of studs under girders equal to the number of plys. All Rebar to be #5 Grade 60 min. MARK LENGTH OF LINTEL ALLOWABLE GRAVITY LOAD APPLIED GRAVITY LOAD ALLOWABLE UPLIFT LOAD APPLIED UPLIFT LOAD BEAM SPECS. L-1 4'-6" 6113 1580 2724 550 817161BAT L-2 3'-8" 6113 408 l 3079 70 8F16 MAT L-3 174" 1326 ' 9 77 732 _ � 8F201B/2T L-4 7-0" 2459 1322 1462 478 8RF14 lB/lT L-5 8'-0" 1568 788 931 277 8RF141BAT L-6 4'-4" 5206 320 2635 105 SRF141B/lT L-7 3'-8" 6113 250 3079 100 SF161BAT L-8 22'-8" j 450 J 195 316 55 8F16113/2717 L-9 11'-4" 1366 173 798 33 817161BAT L-10 10'-4" 1533 173 914 33 8F161B/1T Mini. Beam depths shown, beams may be increased without convent At Lintels over 24 deep provide (1) #4 vertical rebar tied to Horiz. steel at 24"o.c. along length of lintel to sewer system Quaniry of p5 Aber t bottom of lime) ic; F=flletl grw[ eviry cc z wiarea� I 8F16-1B/1T .}IIII. T 5/8' 45 r,W atb... m aIJ iebar altop5 orl,mA. y "illh Lintel Type Designation Safe Load Table Notes 1. All values based on minimum 4" nominal bearing. Exception: Safe loads for unfilled U lintels must be reduced by 201/o if bearing length is less than 6 1/2". 2. N.R. = Not Rated 3. Safe loads are superimposed allowable loads. 4. One #7 rebar may be substituted for two #5 rebar in 8 inch U lintels only. 5. All safe loads in units of pounds per linier foot. 6. All safe loads are based on simply supported span. 7. Safe load ratings based on rational design analysis per ACI 318 and ACI 530. Composite U Lintel Materials 1. Grout per ASTM C476 fg=3000 psi with maximum 3/8 inch aggregate and 8 to 11 inch slump. 2. Rebar per ASTM A615 Grade 60 3. Concrete masonry units (CMU) per ASTM C90 with minimum net area compressive strength = 1900 psi 4. Mortar per ASTM C270 Type M or S Installation Notes 1. Installation of lintels must comply with architectural and/or structural drawings. 2. U lintels can be field cut to the required length. 3. Cast in place concrete may be provided in composite U lintel in lieu of concrete masonry units. 4. The exterior surface of U lintels installed in exterior concrete masonry walls shall have a coating of stucco applied in accordance with ASTM C-926 or other approved coating. 5. Concrete masonry units used in composite U lintel shall be laid in a running bond. 6. Shore composite lintels as required. 7. U lintels are manufactured with a 5 1/2" long notch at both ends to accomodate vertical cell reinforcing and grout. Cast in place sill or Tie Beam Option In the event that precast products are damaged in the field cast in place sills and tie beams may be used (not to exceed 5'-10") Typical cast in place tie beam to be a min. 8" x 12" with (2) #5 top and (2) #5 bottom PLUMBING NOTES: Plumber to consult with contractor and equipment ordered for rough in dimensions. Verify all dimensions with the floor plan. The floor plan dimensions dictates all other dimensions on other sheets. Do not scale drawings, if any conflicts arise, contact the Architect or Engineer for clarification prior to construction, All sanitary lines 2" or less shall have a slope of 1/4" per foot minimum. All sanitary lines above 2" shall have a slope of 1/8" per foot minimum. Provide Anti -Scalding Valve in all showers Lowest living area floor elevation (refered as 0.00') to be set by a professional land surveyor to the required building department elevation, but not less than 18" above the crown of the road. U H � � M O W N � z � to u+J � Q U .,>, o w Q U Q O CCj r--t U L N Uaz00 00 n/ M U z Cd Q U N a Q pw V' z Cn drawn s.1. checked 6.1. date 1/23/19 scale as noted job number 18058 sheet A-3 Roof Plan Scale: 1 /8" = l'-0" 4' Wind Zone - Roof Plan Wind Zone's - Walls Attic Vents Calculation ENTRY, PORCH, and GARAGE Attic Area: 1105 s.f. / 150 = 7.36 s.f. required. soffit area = 84.0 l.f. x 1.3 = 109.2 s.f. Venting Provided: 8 x 16 soffit vent: 85 sq. in. each vent 13 Vents along overhang = 1,105 sq. in. 1,105 sq. in. / 144 = 7.67 s.f. Total Ventilation Provided: 7.67 sq. ft. �I i' i III i N h•—•I O0 � 1n a w � w � z v GQ I •� Q w v Q a ■ E z Two Coat Stucco15 over CBS block 279-36.3 Left Elevation Scale: 1/4" = 1'-0" M Hardie Plank Siding over T,1 House Wrap over 19/32" ram{ A _. _t_.._.._,.a _ U n/ U C) f cC o�00 m M Right Elevation Scale: 114" = 1'-0" Cross Section Scale: 1/4" = 1'-0" w U z Q � N o � � a V' w w a z drawn s.l. checked s.l. data 1/23/19 scale as noted job number 18058 sheet A-4 STEP 5 Apply Horizontal Peel Stick Fashing over Window Fin and Tyvek STEP 2 Window Fin Secured to wood framing as per manufacturers recomen- dations STEP 3 TYVEK Building Wrap over plywood up to Fin of window STEP 4 Apply Vertical Peel & Stick Fashing over Window Fin & Tyvek STEP 3 TYVEK Building Wrap over plywood up to Fin of window STEP 1 TYV> K nuiiotng wrap --. oval' plywood up to Apply Sill Peel & Stick Fin Of window Fas Ing over Plywood. Extend flashing back full width of Jamb Frame Wail Window Flashing 2 x 4 diagonal "X" bracing at 8'-0"o.c. starting from ridge Galy. drip edge with (3) 12d each % min. 4" lap end -i, / 2 x 4 blocking at 4'-0"o.c. starting from ridge between both top and bottom cords for two truss spaces from gable end See truss shop— - drawings span. Nail wrtn (Z) roa l each truss btm. COM Continuous 2 x 4 bracing fastened to beans with 5/8" x 6" wedge bolts with 1/8" x 2" washer 24"o.c. Gable End Bracing Detail 0 o d In .trr.m rn,d hrarinv 10'-0" Bottom Cord Lateral Bracing 1 x 3 p.t. over 2 x 6 Paint Grade Fascia Gable end truss by truss mfgr. 19/32" c.d.x. plywood with 8d nails 4"o.c. Cover with House Wrap 2x "L" web stiffener as required by the truss mfgr. "Simpson" HETA16 truss to bond beam with (14) 10d x 1 1/2" located at each truss vertical Concrete Bond Beam 2" d Pipe Set bal from a� Galv. (4) 1/4" x 2 1/4" % \-Typical Conc. Tapeons foundation Bollard Detail 6" C.M.U. WITH CELLS FILLED i GROUT & (1) #5 VERT. EL P.T. 2 x 6 AT (3) SIDES OF OPENING, FASTEN TO BLOCK AS NOTED. DOOR SIDES 1/2" x 6" REDHEADS WITH MIN. 2" x 1/8" WASHER 12" FROM ENDS AND 24"o.c. MAY. DOOR HEAD 1/4" x 2 3/4" TAPCONS STAGGERED 24"o.c. OR 5/9" x 6" Redheads with Min. 2" x 1/8" washer 12" from ends and 28"o.c. max. OR 1/4" x 1 1/4" min. embedment spaced at 7 1/2"o.c. with I" O.D. washers spaced bottom anchor at 3 1/2" from bottom of 2 x 6 and top anchor at least as high as the door opening. Garage Door Buck Detail Alum. window corrosive resistant frame Tapcon concrete 3/8" continuous bead of srews installed as caulk (back bedding) behind specified in window shim to prevent liquid passage manufacturers product approval 1/4" struct. shim window sill set flange in continuous bead of caulk across the entire face of buck perimeter caulk stucco finish Gunable sealants shall comply with ASTM C 920 Class 25 n grade or greater for proper joint expansion and contraction precast cone. sill 3/8" continuous bead of caulk (back bedding) behind Typical Precast Conc. Sill Detail buck to prevent liquid passage set flange in continuous bead of caulk across the entire face of buck CBS Min. 1 1/4" embedment w ° a at windows and min. �. c 1 1/2" embedment at t Id IVxd/- sl. gl. doors a e a c�v 1/2" drywall QU8 ° ac M stucco finish perimeter caulk 1/4" max. struct. shim Attach p.t. buck7at with $d coil nail caulk12"o,c, attach as per Typ. Alum. manufacturers Jamb or sliding glass product approvals doorjamb NOTE: Method of attachment and Gunable sealants shall comply with waterproofing procedures are the AS TM C 920 Class 25 grade or same at poured concrete sill. greater for proper joint expansion and contraction Coat Bucks with DryLock Waterproofing after they have been installed and Chaulked DESIGNED TO MEET THE REQUIREMENTS OF FBCR 2014 703.8 (FMA-AAMM 200) "FLASHING" Window & Door Flashing Detail at CBS Wall Includes Buck Attachment Method GENERAL ROOFING NOTES Roofing to be composed of and attached to pre manufactured wood trusses as follows: Felt underlayment (min. ASTM 0 226 Type 11) with 4" min. side and end laps, fasten with coorosion resistant annular ring shank nails at 6"o.c. in laps and in staggered rows sppaced 12"o.c. in field. If roof pitch is < 4/12 install (2) layers 15# felt. If roof pitch is 4/12 or greater, install (1) layer 30# felt. 19/32" plywd. sheathingg or equal installed with staggered joints & GI clips, nailed to trusses with 8d corrosion resistant annular ring shank nails spaced max. 6"o.c. throughout, except max. 4"o.c. at gable ends. All roof trusses are to be pre -manufactured assemblies provided by a licensed wood truss fabricator with seperate drawings and data prepared for actual project conditions by a Florida registered proTessional engineer certified for truss design. Any deviation from the proposed plans as shown regarding placement or bearing shall be brought to the attention of the truss engineer prior to fabrication of the trusses. The truss manufacturer's certified layout shall govern after fabrication. The handling, erection, and fixing of wood trusses shall be in accordance with the specifications contained on the certified mfgr's. drawings and data. All engineered headers and truss hangers to be provided by the truss manufacturer. Splitting or cracking of structural components due to installation of hardware is not permitted. Unless otherwise noted, the installation of specified hardware shall conform to the truss manufacturers installation instructions and standard practice. BUCK ATTACHMENT NOTES AT DOORS USE P.T. PINE OR SPRUCE AND ATTACH BUCKS TO BLOCK WITH 1/4" DIA. TAPCONS WITH 1 1/4" EMBEDMENT INTO C.B.S. SET A 6" FROM CORNERS AND AT 12"o.c. MAX. AT WINDOWS USE P.T. PINE OR SPRUCE AND ATTACH BUCKS TO BLOCK WITH 8d CASED HARD COIL NAILS OR "T" NAILS" 4" FROM ENDS AND 12"o.c. USE WOOD SHIMS MINIMUM DURING DOOR INSTALLATION SHEATHING NAILING NOTES Nailing Pattern Zone 1: 8d at 6"o.c. field & 4"o.c. edges Zone 2: 8d at 4"o.c. edges & field Zone 3: 8d at 4"o.c. edges & field Pneumatic Nails Pneumatic or mechanicalp driven nails will be accepted under the following conditions: Min. nails size 8d or larger ring shank with Min. shank diameter: . 113 Min. Length: 2" Min. Head Diameter:.280 Full Round Min. Ring Diameter .012 over shank dia. Min. 16 to 20 Rings per Inch Note Gun nails shall be permitted as an acceptable fastener from any manufacturer Wood screws meeting the same size requirement may be used in lieu of nails without comment Nailing Schedule ROOF & FLOOR DIAGRAM Use sheathing with #8 gun nails at 6"o.c, at supported panel edges and #8 gun nails at 6"o.c, at intermediate supports. ROOF SHEATHING TO GABLE END FRAME Use #8 gun nails at 4"o.c. EXTERIOR SHEATHING Use #8 gun nails at 4"o.c. at panel edges and #8 gun nails at 4"o.c. at panel top and bottom and 6"o.c. in field THRESHOLD NOTE At egress door (see floor plan) the max. hgth. of the threshold shall be 1/2" corner bars at beam (outside only) (2) comer bars at footing (min.) — verf dowel lapped with wall reinforcing, all laps 25" (min ) in grout filled cell all corner bars to be the same size, number, and spacing as horizomial bars ' I in footing, beams, and walls ��—� — — — — — -- 41 I I 22 1/2" leo min. Corner Reinforcing Detail STRUCTURAL NOTES: All reinforcing steel shall be high strength billet steel and shall conform to ASTM A-615 grade 60 specifications. Lap continuous reinforcing 48 bar diameters or 30" in beams and in slabs. Lap bottom steel over supports and top steel at midspan. Hook discontinuous ends of all top bars. Reinforcing steel shall have a minimum of 1" concrete cover, or as follows: BOTTOM TOP SIDES I Beams: 11/2" 11/2" 11/2" Slab on Grade: 1 1/2" 1" _ Structural Poured: 3/4" 3/4" Poured Walls: _ 3/4" Slabs exposed to the weather 3/4" 1" Reinforcing steel shall be detailed and fabricated in accordance with the "Manual of Standard Practice of Detailing Reinforcing Concrete Structures" and the current "ACI Building Code 318' All structural steel shall conform to current ASTM Specification A-36 All wood in contact with masonry shall be pressure treated or approved seperating material. All dimensions shall be verified in field by the contractor. If there are any discrepancies the Architect or Engineer shall be notified before proceeding. i No slump over 5" shall be permitted for any structural concrete without the Architect or Engineer approval. All Design and Construction shall be inaccordance with the current American Concrete Institute (ACI). and the American Institute of Steel Construction (AISC), The Florida Building Code and all applicable local codes. Structural Concrete shall attain a minimum ultimate compressive strength' (Fe') in 28 days as follows: Column Footing and Wall Footing: 3000 p.s.i. Column and walls from foundation to roof: see column schedule. All other concrete: 3000 p,s.i. Footing sizes and reinforcing are based on allowable soil bearing capacity of 2000 p.sd. All footings shall bear in virgin soil. If this is not the case, the Architect or Engineer shall be notified before proceeding with the work, Timber (Heavy Timber Construction) (a) Truss manufacturer shall submit a signed and sealed shop drawings by a registered Engineer. (b) Wood rafters to have a Stress Grade of Fb=1200 p.s.i. (c) Roof members should be secured to the beams or other structural components with hurricane anchors for wind uplift. All wood members shall have a minimum fiber stress in bending of 1200 p.s.i. with 1/360 max. deflection. All bolted connections shall be 1/2" Cadmium plated or better. Lag bolts to be used only in shear connections with minimum 4" threaded penetration past steel plate. Lag bolted conditions shall be drill tapped no larger than the internal thread diameter and shall not be hammer driven. Under Girder Trusses provide equal number of studs as girder plys at frame bearing locations GENERAL REQUIREMENTS All work to be as per the current edition of the Florida Building Code and meet or exceed all applicable local requirements. General contractor is responsible for all labor, materials, utilities, testing, waste removal, storage, securing of site, accomodation, transport/freight, and all other cost related to the completion of this project., unless explicitly identified here. Owner is responsible for all municipal related charges such as impact fees, and water connection, except building permit fees, which are to be included in the construction bid. General contractor to check all drawings for errors and ommissions and bring them to the attention of the architect prior to starting any work, or ordering any materials of the respective division of work. If such errors and ommissions are not reported in writingto the architect, any resulting damages or costs shall be born entirely by the general contractor. Architect is not responsible for the contractors method or means of construction. General contractor is to keep the site in a clean and safe state through out the course of construction. On building turnover, general contractor to clean all surfaces so as to be free of dust, grease, stains, scuffs, etc. Unless otherwise noted, the installation of specified hardware shall conform to the manufacturers instructions and standard practice. All plans and drawings are not considered complete until they have been reviewed And approved by the St. Lucie County Building Department and the building permit has been issued. EXTERIOR CEILING & SOFFIT NOTE 7/8" Stucco finish over 3/8" high ribbed galv. wire lath fastened to framing members with No. 11 guage nails with 1 3/4" embed. with 3/8" dia. head 6"o.c. max. edges to be tied and nailed at 9"o.c. Provide one layer of 15# felt to framing prior to installing wire lath. INTERIOR WALL FRAMING NOTE Interior non bearing walls to be 2 x 4 studs 24"o.c. Spruce, Pine, Fir (SPF) #2 Grade lumber or better or metal studs (25 Ga.) Crimper may be used in lieu of screws. tr 00 FBI � M P; rC) L7 �; � W O .-• P "C3 a > � w ��CC3l W a� LU V A 0 � W o �✓ O Ct ;> U Z Ug 00 a 0 1 U W � w Y U �I at U w Q COO C7 drann checked 5,L date 1/23/19 scale As Noted job number 18058 sheet A-5 5/8" dia. x 10'-0" long ground rod 'dt 3 3W Electrical. Load Calculations 2656 Living S.F. at 3 VA 7968 watts Two 20 Amp Appliance Ckts. 3000 watts One Laundry Cit. @ 1500 watts 1500 watts One Range 9000 watts One Dishwasher not One Disposal @ 1500 watts each 3000 watts One Microwave @ 2000 watts 2000 watts One Water Heater @ 4.5 kw 4500 watts One Wall Oven 8000 watts One Dryer @ 5 kw 5000 watts One Ref. @ 1500 watts 1500 watts Three Baths @ 1500 watts each 4500 watts Total 49,968 watts First 10 KVA at 100% 10,000 watts Remainder at 40% 15,587 watts Total 25,587 watts One AC Heat at 100% 10,000 watts Total 35,587 watts 35,587 W / 240 V = 148.2 Amps Use 200A Service Smoke detectors wired to 120V Bathroom lights Non Switcbable, Non GFI Electrical contractor to verify all equipment loads prior to start of cdtlstruction. Electrical contractor to recalculate electrical schedule if loads are to be modified (3) #2/0 (THW) copper and (1) #4 ground (THW) copper in 2" galy. conduit Panel: 200 A.M-C B I 200 Amp l,e, 3W 40 Circuit Panel 120/240 Volt disc. 3/4" copper water pipe 8, i1„ (3) #2/0 (THW) copper and (1) #4 ground (THW) copper in 2" galy. conduit Wall F.P.L. service (if overhead service) G (3) #2/0 (THW) copper and (1) #4 ground (THW) copper in 2" galy. conduit F.P.L. service (if underground service) ground wire footing rebars Electrical Riser Diagram ELECTRICAL LEDGEND RECESSED C IGHT WITH LENS @ EXTERIOR & WET LOCATIONS SURFACE MOUNTED LIGHT FIXTURE SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE UNDER CAHINET FLUORESCENT FIXTURE RECESSED INCANDESCENT LIGHT FIXTURE WITH EXHAUST FAN CEILING FAN EXHAUST FAN OUTLET THERMOSTAT DUPLEX OUTLET -SWITCHED DUPLEX OUTLET 220 V OUTLI?T SWITCH THREE WAY SWITCH SMOKE & CARBON MONOXIDE DETECTOR -l+ TELEVISION TELEPHONE l PUSH BUTTON y} DIMISAER SWITCH D NOTE: RECEPTACLES IN KITCHEN & BATH AREAS TO BE 46" A.F.F. ALL 120V SINGLE PHASE 15 & 20 AMP BRANCH CIRCUITS SUPPLYING OUTLETS THAT ARE? NOT GFCI MUST BE AFCI. Electrical Notes 1. All loads to be checked by a Florida Licensed Electrician 2. All work to meet the National Electrical Code 3. Calculations and panels below are for sizing conduit and overall building load requirements only 4. All conductors to be copper; all insulation to be THHN. Conduit as follows: PVC below ground, Rigid from underground to service box for exterior lights on building; AC, MC, or EMT conduit elsewhere. 5. Ensure min. 36" clear between equipent and disconnects, Typical. 6. Protective ratings shall comply with NEC 110-9 & NEC 110-10 7. Ensure panels have main disconnect at meter pack per NEC 230-70-A-1 TAMPER PROOF RE( EPTICALES MUST BE INSTALLED IN 120 VOLT, SINGLE PHASE 15 & 20 AMP BRANCH CIRCUITS To Switch Scale: 1/4" = l'-0" at Foyer a\ � M Con w W N U OC • r..,t W W OC V •� ~ .>coo U [-� 3-t -1 W Q C) rrCt � Q � o W N C7 O O ct t—i H � U cC O N 00 �/ M W W U W d) -a � � w a� v a V' w drawn sl. checked s.l. date 1/23119 scale as noted job number 18058 sheet A- 6 0 �O v a H34 s.h. 25 s.h. Safety Glass FIB 70'-0" 24'-0" 12'-8" 24'-0" 9'_4" 1 F-7" 9.6" 2'-11" 4'-3" 3'-10" 4'-4" 3 T-4" 3'-2" 5'-9" 3'-10" 3' l0" 4'-9" 1'-4" 4'-11" 4'-5" 25 s.h. 25 s.h. Egress Egress 4" 14'0" 8" T M-------------- M ----- - -------------- ---------- --- o Master Bdrm. sh. M ! ! " s.h Porch 9'-4" Ceiling 9'41 Cing. from FEE 8" 3'-0" 5' 4" o � LJ M O N Cafe o 0 - Header °° 9'-4" Ceiling at 96" o 0 O p w 25 s.h. 25 s.h. 25 s.h. on 42" Taa�s Wall o0 2680 (�460) Header ( Pocket 4' 4" 3'-3" 1'-5"\5'-4" 3' 8" at 96" o T-8" 5'-0" I j 20'-0" 12'-0" 8" 36" x 72" 00 914" i I Tub Unit Cing. Bdrm.2 _ 9'-4" Ceiling _ r. I I I II I d.w. 1 1 I Family d. — I 3'-6" 8'-6" 2880 I 11'-4" Ceiling d1l 26ao 9'-41' b� i I Cing. i` Range & o Exh. Hood I VTR N P° T= �12" 5'-8" 12" ^ r 9'4" ;p i I I I i Cln Header Kitchenat 96" Header I I O 9'-4" Ceiling at 96" _ cv N----- o Wall Ref O 2080 o Bollard N U Oven Header --------- ato L. R11 bau insul. in at 96" ime v do 0 F. 2ock L9�-4" =_ adj. walls __= Pocket = I'-6-' 3 9'_4" Y-8" 9'-4" 0^ 1 1 Clog. ti� eC Clog. 2880 8"1 9'-8" 13'-0" 12' 12'-0" j 7-8" 2'-0" 8 -4" 1'-8" 3'-6" 51_6" 2'-8" N F-----------i Header `D at 96" I w o I I �-----------J N Dinin g 22.5 x 54 Attic B rm.v 4 I Access with 9'-4" Ceiling g - Ladder = 9'-4" Ceiling I � i Ulm,� I I I M N o0 M 3080 Dr. and (2) 12" V v Impact Side ti6R I M Lites I 25 s.h. 25 s.h. 25 25 s.h. s.h. Egress Egress 8" 23'-8" 8" E. N Bdrm° 3 Garage 9'-4" Ceiling from FEE 9'-4" Ceiling 9'-4" Ceiling - --- - --- --------------- from FFE -- --- --_- - ------ --- -------------- -- ----- 8" I T-0" 8" 25 M n s.h. 25 25 s.h. s.h. Egress 5'-9" 5'-9" 6.9" 6-9" 1'-8" 2'-5" 4'_2" 2'-5" 1'-8" 3'-6" 3'-6" 1'-8" T-5" T-2" 2'-5" 1'-8" 11'-6" 13'-6" 12'-4" T-0" 12'_4" 6'-8" 6-8" 25-0" 31'-8" 13'_4" Floor Plan Scale: 1/4" = F-0" 25 s.h. Egress H34 s.h. Safety Glass H34 s.h. HB Proiect Data Project Name: Day Residence Street Address: T.B.D. City: Ft. Pierce County: St. Lucie State: Florida Scope of Work New One level CBS m Single Family residence Building Code 0 2017 Florida Building Code: Residential 26i 4 National Electrical Code: NFPA 70 Building Data Occupancy Type: Group R Construction Type: V Number of Stories: One Project Area: 3746 s.f. Design Loads Roof Live Load: 30.0 p.s.f. Wind Speed: 160 MPH Wind Importance Factor: 1.0 Building Category: II Wind Exposure: C Internal Pressure Coefficent:.18 Structure Designed: Enclosed Soil bearing capacity: 2000 p.s.£ Area Tabulation Living: 2656 Garage: 625 Porch: 267 Entry: 213 Total: 3761 Total Cubic Volume: xxxx Climatic & Geographic Design Criteria Weathering: Negligible Termite Area: Very Heavy Flame Spread Index & Smoke Developed Index Insulation Flame Spread: Not to exceed 25 Insulation Smoke Developed. Index: Not to exceed 450 Wall Finishes: Not greater than 200 Ceiling Finishes: Not greater than 200 5V Metal Panels over 30# Felt on 19/32" c.d.x. plywood fastened as per nailing schedule Pre Engineered Wood Roof Trusses 24"o.c. Shop Drawings by o Others See Connector 1Schedule 0 N Spray Foam Insulation J �n 9' 4„ T.O _B. - — - 1/2" d.w. 1 x 4 p.t. Firestop Two Course Perimeter Beam with (1) 45 Rebar in each course, Filled with Grout 1 x 2 p.t. flaring strips 24"o.c. with R4.1 Foil insulation 1/2" & #5 vert. rebar in grout filled cell See Floor Plan for Locations 4" 3000# Fibermix Conc. on .006 Vapor Bearier on Clean, Compacted, Termite Treated Fill -- F_F.E. v (2) #5 Rebar 0 M 12 a Varies o, ^ J�•1 M r� F-1 � � w a "o d 110 v� w tA Q W r ° ¢ U ..>. z Q 4E U Q � � o W N C7 o . I. FDOH in St. Lucie County Environmental Health Site Plan Approved for Construction Supersedes All Previous Site Plans for OSTDS -sF- lglllZ q & Well # 59 1 �( Date* Reviewer: L Galv. Drip Edge over 1 x 3 p.t. 2 x 8 R.S. Pine Fascia Board F-6" Stucco Soffit Over High Ribbed Wire Lath Install one layer of 15# felt to framing prior to installing wire lath 8x16x8 CMU Typ. Light Textured Stucco Finish Lap Siding Look Stucco Pattern on Front Elevation 6 1/2" Exposure #5 Vert. Rebar with 10" Hook and 30" Lap. Tie to Vert. Rebar In Cells I �D Grade 11 it • O Typical Wall Section drawn checked s.l. date 1ona/ls scale as noted job number 18058 sheet A-1 SCANNED BY St. Lucie County 12 Contractor Copy H34 s.h. 25 s.b. Safety Glass 0 Co 70'-0" 24'-0" 12,_8., 24,_0n 9.•4„ 11'-7" 9-6" T-11" 4'-3" Y-10" V-4" -4" 3'-2" 5'-9" T-10" 3'-10" 4'-9" 1'.4" 4'-11" 4'-5" 25 s.h. 25 s h. Egress Egress 8 n 14'-0" o-------------- 4,_0n 4 ----- - -------------- --------- ---------- ----_ ---°° _ 50 t Master Bdrm. 25 s h. 25 S h. 1 1 1 ' C " Porch ? " I I I U ' ° w O N 9'4" Ceiling = 914" Cing. from FFE 8" 3,_0n 5, n QNY N Cafes u o° I Header " 00 9 -4' piling ` at 96 •� 5t� Tem 3 LXI� c w 25 25 25 +� .Glass 4 " lA $ 00 i it, s.h. s 1L s iL 2680 in ��; W ca lU 00 c 8Q ii Header o�� 1 I ocket n 4 n� kL 3._3n F-5n 5,-4n T. 8n , I at 96" c -8. 5.-0„ { 20'-0" �,dn,t 1 -0" $n T RrT T\ I I M ( A �y'tJ+—c 36" x 72" Tub Unit 00 vw 9'-4" Cing. ail ^ i ib t �p r D 2 . -F I i 11 ----•� � I �'� t✓�9'-4" ..piling 11 I d.w. it ' Family d. v tw.fLnd.2880 y ao (a1 00i11' 4n Ce1CrTs ; ; I ivtL"jge140 I 00 ofb P: V i i iZ,1 t i C ~• Il2" It 5'-8" 12" a 'v �,91-41 C1 %r ng. • ; I I 1 1 I I >i` Kitchen M "a 9V II I Header 1 I O `r 9'-4" Ceiling at 96" _ II —•-- - t� Header 2080 ( I 00 cw a0 Wall Bollard R1 I bait jnsul_ N Oven I iw L. in add. walls at M --- F • ti� ) n r lA 80 P et -- F-6" 3 9'-4" 3' 8" I1 " i i 9'-4" Cing. dry$ r n ,6 Cln . 2880 C 8n 9._g„ 13'-0" 12 12,_On ` 7._8„ 2,_On �n 1, 3, n 5.-0n�g o r--�-------- Header 101"`' 4-� t _ v , at96" • 1 > 8----------j - g 1 1 22.5 x 54 Attic N B drm. 4 v o Access with 9'-4 Ceiling i $ Ladder }(v^ 9'-4" Ceiling �$ i c� 13 3080 Dr. and (2) 12" 4d Impact Side yb I , lri Lites t 25 25 25 s.h. 25 s.h. { s.h. s.h. I I Egress Egress pp 18„ 23,_8„ 8n I EiV k 1 � t"^ h - B drm. 3 b 9'-4" Ceiling ' Garage from FFE 9'-4" Ceiling 9'-4-1 Ceiling -- -- --_ ----------- ---- ---------- ------------- ---- --- ---' -------- ------ --- --__ _--------- --- - ------------ - --- --- from FFE _ _ 8" 12'-0" 8" • 25 M = s.h. o0 25 35 s.h. s.h. Egress 5'-9" 6-9" 6'-9" 1'-8n 2,_5n 4,_2n 2,_5n 1,_8n 3,_6n 3,_6n 1._8„ 2,_5n 4,_7n 2.-5" 11_8n 1l'-6" 13'-6" 12'4" 7'-0" 12'-4" 6-8" 6-8" 25'-0" 31'-8" 13'-4" r Floor Plan Scale: 1/4" = I'-0" r e., Project Data Project Name: Day Residence Street Address: T.B.D. City: Ft. Pierce County: St. Lucie State: Florida Scope of Work New One level CBS Single Family residence - Building Code 2017 Florida Building Code: Residential 20t4-National Electrical Code: NFPA 70 Building Data Occupancy Type: Group R Construction Type: V Number of Stories: One Project Area: 3746 s.f Design Loads Roof Live Load: 30.0 p.s.f. Cq Wind Speed: 160 MPH f--^ � Wind Importance Factor: 1.0 en Building Category: 11 uo j Wind Exposure: C () Internal Pressure Coefftcent:.18 Structure Designed: Enclosed Soil bearing capacity: 2000 p.s.f. Cz7 a Area Tabulation W Q w 00 N Living: 2656 Garage: 625 - ;a. v Porch: 267 q Entry: 213 CIS z W O F" Total: 3761 Total Cubic Volume: xxxx d� W o Climatic & Geographic Design Criteria Weathering: Negligible Termite Area: Very Heavy Flame Spread Index & Smoke Developed Index Insulation Flame Spread: Not to exceed 25 Insulation Smoke Developed Index. Not to exceed 450 Wall Finishes: Not greater than 200 25 s.h. Ceiling Finishes: Not greater than 200 5V Metal Panels Egress over 30# Felt on 19/321, c.d.x. plywood fastened as per nailing schedule Pre Engineered Wood Roof Trusses 24"o.c. o � wings by 0O rs See Connector Schedule 4 12 over Drip Edge FILE COPY Spiny F� �] Varies over 1 x 3 p.t H4 s.h. Insulation Glass 9141f_ T.O.B. 1/2" d.w.✓ ; EI 'i 2 x 8 R.S. Pine 4 s.L 1 x 4 p.t Fascia Board Firestop 1' 6" Stucco Soffit Over -�- Two Course Perimeter „ High Ribbed Wire ab HB Beam with (1) #5 Rebar ii' in each course, Filled ii Install one layer of 15# With Grout;j fait to &arcing prior to installing wire lath i x 2 p.t. furring ,I 8 x 16 x 8 strips 24"o.c. CMU Typ. _ with R4.1 Foil insulation Light Textured 1/2" d. ;i Stucco Finish #5 vert. mbar in i Lap Siding Look grant filled cell Stucco Pattern: on Front Elevation See Floor Plan for Locations ;; 6 1/2" Exposure , 4" 3000# Fibermix Conc. _ II ,.1 #5 Vert. Rebar with _ on .006 Vapor Bearier on T;;; ;;i 10" Hook and 30" Clean, Compacted, Termite Lap. Tie to Vert. Treated Fill --\ �;; Rebar In Cells Cw1cr cr'(CS- I- . cA-UY i(.o-)l I 0.00'- F.F.E. -_ ;li 'v ;i toGrade it \ 'CD (2) #5 Rebar Typical Wall Section ai checked t.L dale 101E Fl18 scale "Mted job nwnber 18058 sheet A.- i 8CANN� J St Lucie COunl, C O 0 0 tt a r` LO [' 70 00 !1n CRIAERRVAE TRUSS END DETA AIIL PWME C0 GWILIEVER s TRUSS CONNECTION LIST QTY PRODUCT LUS24 35 HTU26 HTU28 HHUS26-2 3 HGUS28-2 HGUS26-3 HGUS26-3 NO PSF LL 'BE NOTES: 1.)REFER TO HIB 91 (RECOMMENDATIONS FOR HANDLING INSTALATION AND TEMPORARY BRACING.) REFER TO ENGINEERED DRAWINGS FOR PERMANENT BRACING REQUIRED. 2.)AII TRUSSES (INCLUDING TRUSSES UNDER VALLEY FRAMING) MUST BE COMPLETELY DECKED OR REFER OR DETAIL V105 FOR ALTERNATE BRACING REQUIREMENTS. 3.)ALL�'�YAIS TO BE CONV T Y UILDER. 4.)ALL TRUSSES ARE DESIGNED FOR 2' o.c. MAXIMUM SPACING UNLESS OTHERWISE NOTED. 5.)ALL WALLS SHOWN ON PLACEMENT PLAN ARE CONSIDERED LOAD BEARING UNLESS OTHERWISE NOTED. 6.)SY42 TRUSSES MUST BE INSTALLED WITH THE TOP BEING UP. 7.)BEAM/HEADER/LINTEL (HDR) TO BE FURNISHED BY BUILDER. Jacksonville PHONE:904-772-6100 FAX:904-772-1973 Tampa PHONE: 813-621-9831 FAX:813-628-8956 Freeport PHONE:850-835-4541 FAX:850-835-4532 BUILDER; BY --- St. Lucie County TREFELNER CONST LEGAL ADDRESS: 3148 BROCKSMITH ROAD FORT PIERCE, FLORIDA MODEL: I Revision: DAY RES Rev. By: p( e erenc ,D .10 V" v� IK DATE: Drawn By: 01-04-2019 Jim W MITEK PLATE APPROVAL #'s 2197.2 - 2197.4, WEYERHAUSER PRODUCT #'s 1630.2 - 1630.10 1593771 1593771