HomeMy WebLinkAboutCOMPACTION TEST1q oa - tt y 0Z-U031-) EI & TESTING, INC. Phone: (866) 781-6889 *Fax: (866) 784-8550 i1-ivw.tloridaengineeringandtcsting.com 250 S.W.131b Avenue Pompano Beach, FL 33069 PROCTOR COMPACTION TEST DATE SAMPLED: 3/29/2019 DATE TESTED: 4/3/2019 ORDER #: 19-1668 CLIENT: Delahunty Construction ADDRESS: 906 N.W. Sassafras Terrace Jensen Beach, Florida 34957 PROJECT: Proposed One Story Addition SCANNED ADDRESS: 4479 Indian River Drive Fort Pierce, Florida Gf I „rip r.Gunty MATERIAL DESCRIPTION: Brown Fine Sand SAMPLED BY: W.B. SPECIFICATION GOVERNING: TESTED BY: P.T. . ASTM D-1557, Method C LAB NO: RESULTS OF TEST: P-1668 The following compaction test was conducted in accordance with the Standard Methods of Moisture Density Relations of soil using a 10 Ib. Hammer and an 18" drop as per the above specified method. MOISTURE % 8.3 10.2 12.5 14.7 Optimum Moisture (Percentage): 11.9 % Maximum Dry Density (Ibs./cu.ft.) 107.8 (PCF) Respectfully Mark A. MesiaiU Florida Engines=rr. Florida Reg. No. Certificate of Aul WET DENSITY (PCF 1111111/// �N IyFs iENSF •.Z9y�ii i 4820'1 113.1 118.0 121.2 119.7 112 111 110 Ei 109 a 108 Z 107 O 106 } p 105 104 103 + 7 DRY DENSITY (PCF 104.4 107.1 107.7 104.4 8 9 10 11 12 13 14 15. MOISTURE % "I/11111111V4• As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, contusions or extracts from or regarding our reports is reserved pending our written approval. Quaktq ��jG��f� ✓Lssurnnee ENGINEERING & TESTING, INC. Phone: (866) 781-6889 •Faa. (866) 784-8550 wii w.floridaengineeringandtesting.com 250 S.W.13" Avenue Pompano Beach, FL 33069 REPORT OF FIELD COMPACTION TESTS DATE: 3/29/19 ORDER NO: 19-1667 PERNHTNO. S�-D CLIENT: - Delahunty Construction - — St ,UCI BY ADDRESS: 906 N.W. Sassafras Terrace Jensen Beach, Florida 34957 County PROJECT: Proposed One Story Addition ADDRESS: 4479 Indian River Drive Fort Pierce, Florida MATERIAL DESCRIPTION: Brown Fine Sand PROCTOR VALUE (PCF): 107.8 OPTIMUM MOISTURE (%): 11.9 % COMPACTION REQ'D BY SPECS: 95* LABORATORY NO: P-1667 NUCLEAR GAUGE SERLAL #: ❑ 29793 (Model 3440) ® 533 (Model 3450) ❑ 20500 (Model 3440) PROCTOR METHOD: ® ASTM D-1557 ❑ ASTM-D698 ❑ AASHTO T-180 ❑ AASHTO T-99 ASTM D 6938 METHOD A Test k Location: Lift ElevJ Depth of Test Dry Density C19 Moisture (%) Percent Compaction (%) Pass/ Fail 1 Center of S. End of Slab SOG 12" 102.4 4.7 95.0 P 2 Center of Slab SOG 12" 100.6 4.6 93.3 F 3 Center of N. End of Slab SOG 12" 105.8 7.1 1 98.1 P 4 E. Column Pad BOF 1 12" 89.2 10.1 82.7 F 5 N. Column Pad BOF 12" 84.5 11.8 78.4 F 6 7 8 9 10 REMARKS: A subsoil investigation bas not been performed by F.E.T. *95% compaction per client. TESTED BY: W.B. CHECKED BY: P.T. Respectfullysubri0folll/tfjjiAN �� Notes: NNNN 1" ::.. 41, Method A - Direct Transmission unless otherwise noted.��i PR - Proof Roll BOF - Bottom of Footing (! A 2 2 `O TOB - Top of Base SG - Subgrade MARK A. 7' O61 . . * SOG - Slab on Grade Florida Enawkng & Asting, 4 As a mutual protection to clients, the public and ourselves, all reports Florida Reg '.48Z� oP are submitted as the confidential property of clients, and authorization Certificate ofor ublication of statements, conclf D1cgII�3 ourreports is reserved pending ourusions written approvaor lfrom or regarding//ONA1,��NN �A& �'rY Quality � Qt1 Jlsstss ar:ce 4 AL ENGINEERING & TESTING, INC. Phone: (866) 781-6889 •Fax: (866) 784-8556 w,a-w.noridaengineeringandtesting.com 250 S.W.13`s Avenue Pompano Beach, FL 33069 REPORT OF FIELD COMPACTION TESTS DATE: 4/2/19 ORDER NO: 19-1668 CLIENT: PERMIT NO. .. � .�'�� ADDRESS: 906 N.W. Sassafras Terrace Jensen Beach, Florida 34957 CO/g,,� Y PROJECT: Proposed One Story Addition ADDRESS: 4479 Indian River Drive Fort Pierce, Florida MATERIAL DESCRIPTION: Brown Fine Sand PROCTOR VALUE (PCF): 107.8 % COMPACTION REQ'D BY SPECS: 95* NUCLEAR GAUGE SERIAL #: ® 29793 (Model 3440) PROCTOR METHOD: ® ASTM D-1557 ❑ ASTM-D698 OPTIMUM MOISTURE (%): 11.9 LABORATORY NO: P-1667 ❑ 533 (Model 3450) ❑ 20500 (Model 3440) ❑ AASHTO T-180 ❑ AASHTO T-99 1/ 1 SlCli1/1_410_:_C13 W. Test # Location: Retest Lift Elev./ Test Dry Density Densof Moisture ("�o) Percent Co paction Pass/ Fail 1 N. Column Pad BOF 12" 105.7 4.3 98.1 P 2 E. Column Pad BOF 12" 103.1 5.6 95.6 P 3 Center of Slab SOG 12" 105.2 6.9 97.6 P 4 5 6 7 8 9 10 REMARKS: A subsoil investigation has not been performed by F.E.T. *95% compaction per client TESTED BY: J.R. CHECKED BY: P.T. Respectfully sul�", 1811111/J11 . J\\ PAN Notes: _ �\ �10Ey8• ;Sj Method A -Direct Transmission unless otherwise noted. 1---� . PR - Proof Roll BOF - Bottom of Footing SYtI yNo. 48209 ` O TOB - Top of Base SG - Subgrade MARK A. j1AN0, ,,V.E. SOG - Slab on Grade Florida Eng*gTg 8TP'] g,14* As a mutual protection to clients, the public and ourselves, all reports Florida Reg.102 N are submitted as the confidential property of clients, and authorization Certificate of,Li�2aAi�ig\� for publication a lica statements, onclusinso extracts from or regarding ' ouris roervedpendingapproval. xe a U�Q Ul Qualify �\yA�� assurance