HomeMy WebLinkAboutPLANSGeneral Notes A. CONCRETE & FOUNDATION DESIGN: 1. ALL CONCRETE GRADE BEAMS AND FOOTINGS SHALL BE 3000 PSI MINIMUM. 2. ALL CONCRETE FILLED SUPPORTED SLABS SHALL BE 2500 PSI ,MINIMUM, 3 1/2' NOXIINAL THICKNESS. 3. FIBERMESH (314" PER CUBIC YARD MIN.) MEETING APPROPRIATE ACI AND ASTM REQUIREMENTS MAY BE USED IN LIEU OF WELDED WIRE MESH 4. ALL SLABS ON GRADE SHALL BE 4" THICK WITH FIBERMESH. 5. ALL REINFORCING SHALL CONFORM TO ASTM A615, BE GRADE 60 (60 KSI MIN.) DEFORMED BARS, #3 BARS MAY BE GRADE 40 6. ALL OVER POUR CONCRETE FILLED SUPPORTED SLABS SHALL BE 3000 PSI MIN, 2" MINIMUM. THICKNESS. 7. SOIL BEARING PRESSURE SHALL BE A MINIMUM OF 1500 PSF. S. THE CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING: OPC (PORTLAND CEMENT TYPE 1,- ASTM C 150). AGGREGATES - 96 STONE, ASTM C 33 SIZE NO.67 LESS THAN 3/4". AIR ENl'RAINING+/- 1%- ASTM C 260. WATER REDUCING AGENT - ASITA C 494. CLEAN POTABLE WATER. OTHER ADMIXTURES SHALL NOT BE PERMITTED. 9. METAL WELDED WIRE SHALL CONFORM TO ASTM A 185. 10. PREPARE & PLACE CONCRETE ACCORDING TO AMERICAN CONCRETE INSTITUTE MANUAL STANDARD PRACTICE, PART 1, 2, & 3 ALONG WITH HOT WEATHER CONDITIONS RECOMMENDATIONS. 11. IF UTILIZING EXISTING CONCRETE FOR FOUNDATION, CONCRETE SHALL BE A MINMUM OF 4" IN THICKNESS, VISIBLY FREE OF ANY STRUCTURAL EXCESSIVE CRACKING, SPALLING OR OTHER DETERIORATION. B. MASONRY: I. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALT, BE 1900 PSI MINIMUM EASED ON TYPE M OR S MORTAR 2. ALL MORTAR SHALL BE OF TYPE M OR S. 3. ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 4.PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS S-0" IN HEIGHT. C. ALUMINUM: 1. ALL STRUCTURAL ALUMINUM SHALL CONFORM TO THE MINIMUM REQUIREMENTS OF 6005-TS FOR ALLOY WITH A MINIMUM THICKNESS OF 0.040" FOR SUPPORTING MEMBERS. 2. WHERE HICK PLATES ARE USED A MINIMUM THICKNESS OF 0.024" SHALL APPLY. 3. STRUCTURAL ALUMINUM DESIGN CONFORMS TO "PART 1-A - SPECIFICATIONS FOR ALUMINUM STRUCTURES - ALLOWABLE STRESS DESIGN" OR "PART 1-B - SPECIFICATIONS FOR ALUMINUM STRUCTURES - BUILDING LOAD AND RESISTANCE FACTOR DESIGN" OF THE ALUMINUM DESIGN MANUAL PREPARED BY THE ALUMINUM ASSOCIATION, INOWASHINGTON D.C. THE FLORIDA BUILDING CODE 61h EDITION ( CHAPTER 16 STRUCTURAL DESIGN & CHAPTER 20 ALUMINUM). 4. WHERE ALUMINUM COMES INTO CONTACT WITH STEEL, OR PRESSURE TREATED LUMBER PROVIDE DIELECTRIC SEPARATION. 5. ALUMINUM MEMBERS SHALL BE STITCHED WITH NO LESS THAN 410 SMS 6" FROM THE ENDS AND 12" ON CENTER, IF USING N12 SPACING MAY BE 24" ON CENTER. 6. VINYL AND ACRYLIC PANELS SHALL BE REMOVABLE. THEY SHALL BE IDENTIFIED WITH A DECAL ESSENTIALLY STATING "REMOVABLE PANEL SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH". DECAL SHALL BE PLACED SO IT IS VISIBLE WHEN PANEL IS INSTALLED. 7. 1"X2"X0.045" NON-STRUCTURAL MEMBERS SHALL BE ATTACHED TO HOST WITH 114"0 X 1-3/4" EMBEDMENT & 24" O.C. MASONRY SCREW FOR CONCRETE & EQUIVALENT SIZE WOOD SCREW WHEN IN WOOD & #LOX 1/2" EMBEDMENT SMS OR TEK SCREWS IN ALUMINUM MEMBERS TYPICAL. D. FASTENERS: 1. ALL LAG BOLTS SHALL CONFORM TO STAINLESS STEEL TYPE 300 18-9, WITH STANDARD FLAT WASHER UNLESS MANUFACTURER GALVANIZES BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD. 2. HEX BOLTS HAS':'= -•_ ASTM A 325, PLATED WITH STANDARD ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED FLAT WASHERS AND NUTS. HOME. 3. ALL CONCRETE SCREWS SHALL BE, SIMPSON, HE.TI, RAWL, 2. IF ENCLOSURE CONTAINS A SWIMMING POOL OR SPA, THE TAPCON, REDHEAD, DYNABOLT, PORTECT OR APPROVED ENCLOSURE SHALL COMPLY WITH RESIDENTIAL SWIM IING- - - - EQUAL. - - - BARRIER REQUIREMENTS OF THE FLORIDA BUILDING CODE 6Ui 4. ALL METAL TIES AND ASSOCIATED ACCESSORIES SHALL BE EDITION R 4501.17IN ITS ENTIRETY. HOT DIPPED GALVANIZED. 3. DOOR LOCATIONS MAY BE DETERMINED IN THE FIELD BY 5. ALL LAG BOLTS SHALL HAVE A MINIMUM EMBEDMENT OF 8X CONTRACTOR BOLT DIAMETER INTO STRUCTURAL FRAMING (G=.42 MIN.). 4. IF PAVERS ARE UNDER ALUMINUM MEMBERS THEY SHALL 6. LAG BOLTS AND SCREWS INTO WOOD FRAMING SHALL BE HAVE EPDXY ADHESIVE TO CONCRETE OR IF USING GROUT, PROVIDED WITH PILOT HOLES HAVING A DIAMETER NOT ENSURE BONDING AGENT IS USED FIRST. GREATER THAN 70 PERCENT OF THE THREAD DIAMETER OF 5. SCREENING MATERIAL SHALL BE 18X14X0.013 OR THE BOLT OR SCREW. ALL LAG BOLTS AND SCREWS SHALL BE EQUIVALENT DENSITY SCREEN MESH ONLY UNLESS NOTED INSERTED IN PILOT HOLES BY TURNING AND UNDER NO ON DRAWING 8-2. CIRCUMSTANCES BY DRIVING WITH A HAMMER 6. PLEASE NOTE: 2x2 (tyP) DIAGONAL BRACING SHALL BE 7. ALL EXPANSION ANCHORS. SHALL BE DESIGNED IN 2"X2"XO.055"-MATERIAL, UNLESS OTHERWISE NOTED ON S-2. ACCORDANCE WITH THE SPECIFIC MANUFACTURER'S REQUIREMENTS AND ALLOWABLE LOADS AND SHALL ONLY BE APPLIED IN CONDITIONS ACCEPTABLE TO MANUFACTURER. FASTENERS SHALL BE A MINIMUM OF SAE GRADE #5 OR BETTER ZINC PLATED. S. ALL FASTENERS CONNECTING ALUMINUM COMPONENTS OR PRESSURE TREATED LUMBER ARE STAINLESS STEEL TYPE 300 DESIGN DATA: 18-8, UNLESS MANUFACTURER GALVANIZED BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD, OR 1. ULTIMATE DESIGN WIND SPEED Vult, (3 SECOND GUST): OTHERWISE NOTED ON PLANS. NOMINAL DESIGN WIND SPEED Vnd: 9. ALL FASTENERS SHALL COMPLY WITH ASTM A153. 2. RISK CATEGORY: 10. ALL CONNECTORS SHALL COMELY WITH ASTM A653 3. WIND EXPOSURE: CLASS G-185. 4. WINDLOADS: 11. FOR SMS, THE MINIMUM CENTER -TO -CENTER SPACING SCREEN ROOF: 9 PSF SHALL BE 3/4" AND MINIMUM CENTER -TO -EDGE SHALL BE 1/2" - SCREEN WALLS: 31 PSF UNLESS NOTED OTHER WISE. SOLID ROOF (SCREEN WALL): N/A COMPONENTS AND CLADDING LOAD: N/A E. REFERENCE STANDARDS: ASTM E 119 ASTM E 1300 CURRENT ASCE 7 CURRENT ALUMINUM DESIGN MANUAL -AA ASM35, AND SPEC. FOR ALUMINUM PART 1-A, & 1-B ASTM C94 ASTNI C150 ASTM C33 ASTM C260 ASTM C494 ASTM A615 ASTM A185 FLORIDA BUILDING CODE 68, EDITION (CHAPTERS 16,20 & 23). F.ABBREVIATIONS: THE FOLLOWING LIST OF ABBREVIATIONS IS NOT INTENDED TO REPRESENT ALL THOSE USED ON THESE DRAWINGS, BUT TO SUPPLEMENT THE MORE COMMON ABBREVIATIONS. 1. TYP--TYPICAL 2. SIM -- SIMILAR 3. UON-- UNLESS OTHERWISE NOTED 4. CONT-CONTINUOUS 5. VIF-VERIFY IN FIELD G. RESPONSIBILITY: 1. ALL SITE WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDINANCES, ETC. 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND DETAILS, NOTIFYING ENGINEER OF ANY DISCREPANCIES BETWEEN DRAWINGS, FABRICATED ITEMS, OR ACTUAL FIELD CONDITIONS. 3. THESE DRAWINGS REPRESENT THE ACCEPTABILITY OF THE 'SUNROOM' ROOM ADDITION ELEMENTS AS PROVIDED BY THE CONTRACTOR. 4. ALL DETAILS ON THESE DRAWINGS ARE ENGINEERED BASED ON INFORMATION PROVIDED BY THE CONTRACTOR AND MANUFACTURER. 5. ANY DETAILS NOT SHOWN ARE TO BE ENGINEERED BY A LICENSED P.E. IN ACCORDANCE WITH STANDARD A. MISCELLANEOUS: 1. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPARATE 4TH WALL SUPPORT SYSTEM MUST BE ENGINEERED SO THAT NO 150 MPH 116 MPH 1 B 5. THIS STRUCTURE COMPLIES WITH FBCE. 1103.2 AND THEREFORE HAS NO ADVERSE AFFECT ON THE EXISTING STRUCTURE. 6. FACTOR APPLIED TO SCREEN WIND LOADS FOR 18X14X0.013 OR EQUIVALENT DENSITY SCREEN MESH: 0.89 7. FACTOR APPLIED TO SCREEN WIND LOADS FOR ALLOWABLE STRESS DESIGN: 0.6 8. LIVE LOAD: 3001b. VERTICAL DOWNLOAD ON PRIMARY SCREEN ENCLOSURE MEMI3ERS. 2001b. VERTICAL DOWNLOAD ON SCREEN ENCLOSURE PURLINS. S. EXISTING SLAB AND OR FOOTING MEETS THE REQUIREMENTS TO RESIST THE UPLOADS FOR TH1,7 PROPOSED STRUCTURE. 9, SCREEN ROOF TYPE: MANSARD -FLAT 10. SOLIDROOFTYPE: N/A ALUMINUM STRUCTURAL MEMBERS HOLLOW SECTIONS 2 x 2: --------•----------------2„ x 2" x 0.044" 2 x 3:---------------------------------------2" x 3" x 0.050" 2 x 4---------------------------------------- 2" x 4" x 0.050" 2 x 5---------------------------------------- 2" x 5" x 0.050„ 3 x 3:----------------------------------r--3" x 3" x 0.125" OPEN BACK SECTIONS 1 x 2:---------------------------------------- 1"x 2" x 0.040" 1 x 3:-------------------------------------- - 1" x 3" x 0.045" SNAP SECTIONS 2 x 2 SMS----------------------------------2" x 2" x 0.045" 2 x 3 SMS:---------------------------------2" x 3"x 0.072" 2 x 4 SMS: ------------- •------------------- 2"x 4" x 0.045" 3 x 3 SMS: ---------•I--------------------- 3" x 3" x 0.090„ $ELF•MATING (SMB) 2 x 4 SMB:---------------------- 2" x 4" x 0.044" x 0.100" 2 x 5 SMB:------•---•----------- 2" x 5" x 0.050" x 0.118" 2 x 6 SMB:---------------------- 2" x 6" x 0.050" x 0.120" 2 x 7 SMB:-------•------•--•---- 2" x 7" x 0.057" x 0.120" 2 x 8 SMB:---••--� •••-•------• 2" x 8" x 0.072"x 0.224" 2 x 9 SMB:---------r----------- 2" x 9" x 0.072" x 0.224" 2 x 10 SMB ----------------- 2" x 10" x 0.092" x 0.374" TUBE SECTIONS 2 x 2: ----•----- ----------------2" x 2" x 0.090" RECEIVED FEB 0 4 2019 Permitting Department St. Lucie C0141'.t1, ST. LUCIE COUNTY BUILDING DIVISION FOR PLANS AND PERf)RiT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE THESE P"NS AN kLL PROPOSED WoRiI ARE SUEtcCT TO ANY COMECMN9 REOUIRED ON FIELD INSPECTORS THAT UY NE NMERfAAY IN ORDER TO CaiJciY'11TH:! L:,PrI1C �ODfS. CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD r>LA/ Oe ° No.7066', O ' STATE OF �s • °" OR0", liA.9®SIB 6I�'^ ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P FLORIDA LICENSE: 38654 Mark R. Dunn P.E. FLORIDA LICENSE: 73968 Joel Falardeau P.E. FLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans & Engineeril Services, Inc. 6272 AbbottStation Dr. Unit 101 Zephyrhills, FL 33542 Ph# (813)788.5314 Fax# 1-(866)824-7894 E-mail-erb@lbcplans.coln W ebsite-WwW.tbcplans.com C.O.A: #29054 DATE: 1/6/2019 DRAWN BY: TLK REVISION: DAT9Q I-AiAlAir RD 1 RO 2 CC RO 3 RO 4 Job# 18 1226_74 PROJECT ADDRESS: MAY 2503 DYER RD DORT ST. LUCIE, FL 34952 ]ONTRACTOR: K & S INDUSTRIES, INC. 1379 SW BILTMORE ST. PORT ST LUCIE, FL 34983 NOTES PART WTHOUT UPRESSED WRITTEN PERMISSION OF TRAC DESIGN, 1X2 1 2X2(typ) 2X2(typ) I I I S_3 S-4 I I � 2X2(typ) 2X2(typ) IN I I N N I 123 V g 00 00 00 I X N X S-3 N X N 2X2 t 2X2(typ) 2X2(typ) CO CO CO �+ S-3 X X X N N N 2X2 J_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ O ��/ \\ I \ / 1X2 \\ N N N N N N N �p X �p 2X2 t 2X2 t 2X2 t N N N N 0 I to 1X2 �•rri S-4 S-4 �2'-6" ' Od ;v No. 706; 7 s <o STATE O ' C 'NA - David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P.E FLORIDA LICENSE: 38654 Mark R. Dunn P.E. FLORIDA LICENSE: 73968 Joel Falardeau P.E. fLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE; 77605 FBC Plans & Engineerinl Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph# (813)788.5314 Fax# 1-(866)824-7894 E-mail-erb@fbcplans.com W ebsite-urwW,Pocplans.com C.O.A. #29054 DATE: 1/6/2019 DRAWN BY: TLK REVISION: DATE: RO 1 RO 2 RO 3 RO 4 Job# 18_1226_74 PROJECT ADDRESS; DYER RD ST. LUCIE, FL 34952 K & S INDUSTRIES, INC. 1379 SW BILTMORE ST. PORT ST LUCIE, FL 34983 PL00RPLAN S-2 BE REPRODUCED IN WHOLE OR IN 3/16" ALUMINUM GUSSET 2"x_PURLINS (SEE A-1 PLATE FOR SIZE)ATTACHED TO B #12 SMS BEAM w/MIN (4) #30 x 1 j," _ -SMS- \ N'Of 0 0 • \ � do N • 'L \ \ i3`EgRA 6i BEAM "B" "N" "Sl" "S2" "S3" "S4" 2X4 12 4 3/4" 1 " 16" 3.7S" 2X5 12 4 3/4" 1 16" 4.7S" 2X6 16 5 1" 14" 19" 5.75" 2X7 20 6 1" i 22' 6.75" 2XB 24 7 1" 1 23" 7.75" 2X9 24 7 1" 1 " 23" 8.75" 2X10 28 8 1" 1-j" 24" 9.7S" BI EAVE NOTES: 1."N"NUMBEROFSCREWSINANY DIRECTION. 2. TOTAL NUMBER OF SCREWSPER JOINT EQUALS 4 TIMES"B". 3. PLATE WIDTH SHALL BE DETERMINED FROM ANGLE OF BEAM AND MIN. SPACE REQUIRED. 4. GUSSET PLATES MAY BE INTERNAL OF EXTERNAL. S. INTERNAL SCREWS FOR PURLIN CONNECTION MAY BE INCLUDED IN TOTAL NUMBER OF SCREWS. 6. GABLE SPLICE WILL HAVE THE SAME PATTERN. BEAM SPLICE GUSSET DETAIL TYPICAL S SCALE: NTS (1) 3/8.0 THRU BOLT W/ NYLON LOCKING NUT OR THREAD LOCKING MATERIALAPPLIED HINGE (2) #10X3" SMS CROSS SCREWING BRACE TO BEAM OR 2"x2"1 EAVE MEMBER (.I: HACKING PLATE USED) ROOF 2"eZ"x.125" FLAT BAR (typ) HINGE OPTIONAL Z-BRACKET 0.250" 5.OR 7"X 6" WIDTH X 0.250" EXTRUDED GUTTER BRACKET @ EA. BFAM W/ (4) #12 X3/4"— SMS INTO GUTTER LIP 1" x 2" x 0.045" OPEN BACK W/ (4)#14X 1-1/2" INTO CUTTER & (1)#14X 1-1/2' @ 24" O.C. poBEAM 2" x 2" x %" X ALUMINUM ANGLE w/ (4) #14 x 3/4", SMS INTO BEAM ON EA SIDE EA. LEG 2'X2"XO.062" RECENING CHANNEL W/ (2) #10X 3/4" EA SIDE TO COVER EXPOSED BEAM NOTE: 2X4 SMB BEAM ONLY REQUIRES 4" WIDTH GUTTER BRACKEP W/W/ (2) 3/8" LAGS (4) 3/8" LAG SCREWS @ 1-1/2" SPACING @ EA. GUTTER BRACKET & @ 12" O.C. MAX- MIN EMBEDMENT SHALLBE2" THE HOST STRUCTURE SHALL HAVE AT LEAST A 2"X4" SUPER GUTTER FASCIA AND ROOF TRUSS [VERIFY (5"OR 7-) SYSTEM. CONTRACTOR SHALL THIS AND IF #1Z x3/4'SMS SMALLER -CONTRACTOR _(4) INTO GUTTER EA SIDE SHALL BRING STRUCTURE UP TO A 2"X4" FASCIA AND ENSURE LESS THAN A 2'-0' OVERHANG. A GUTTER BRACKET& BEAM ATTACHMENT DETAIL S_3 N.T.S. DOOR x 2" EXTRUSION NOTES: 1. HINGES SHALL BE ATTACHED TO STRUCTURE W/ (3) #10 x 518" SMS MINIMUM. 2. DOOR SHALL BE ATTACHED TO ENCLOSURE w/(2) HINGES MINIMUM. 3. HINGES SHALL BE ATTACHED TO DOOR WITH (3)#10 x 5/8" SMS. FASTEN A 1" x 2" x 0.044" TO UPRIGHT W/# 12 x 1" SMS @ 12" O.C. AND WITHIN 3" FROM END OF THE UPRIGHT. ROOF BRACING CONNECTION DETAIL S_3 SCALE: N.T.S. F TYPICAL SCREEN DOOR CONNECTION DETAIL S' 3 SCALE: NTS UPRIGHT WEB LAPPED OVER PURLIN W/(2)#12X3/4"SMS EACH SIDE THRU UPRIGHT & PURLIN 2"XZ'MEMBER ATTACHED TO UPRIGHT W/ (3) #10XI.1/2' SMS- INTO SCREW BOSS 1"X2"XO.045"OPEN BACK ATTACHED TO PURLIN W/ (2)_ #1OX1-1/2" SMS INTO SCREW BOSS 1"X2"XO.045" OPEN BACK ATTACHED TO 2"X2'Xo.045' FAVE RAIL MEMBER• #IOXI-1/2"SMS @ 24" O.0 C SLOPED OR FLAT PURLIN UPRIGHT LAP DETAIL S'3 SCALE: NTS BEAM SCREWS 2"X4"SMB 6 2'X5"SMB 6 2"X6"SMB 8 2"X7"SMB 8 2"X e"SMB 10 2"X9"SMB 30 2"X 10'SMB 12 FOR SLOPED BEAMS, MAINTAIN ALL SCREW SPACING FROM EDGE OF BEAM 2"x 2" EAVE RAIL SECTION (UNLESS OTHERWISE SHOWN r - ATTACHED TO BEAM w/ (3) 1OX 2" SMS INTO SCREW BOSS 1'X 2' OPEN BACK EAVE RAIL ATTACHED TO #10x 1y,"SMS INTO SCREW BOSS \-2"NOTCH OF INSIDE BEAM #10 X 1 X" SMS 24" C/ TO SLIDE OVER UPRIGHT #14X 3/4" SCREWS (SEE TABLE ABOVE) " (MINI) UPRIGHT ( U \ UPRIGHT TO BEAMCONNECI'ION-ALL WIND ZONES S_ l SCALE: NTS i 'SELF -MATING BE/ -SHALL BE NOTCH �5/1 FORUPRIGHT OOiIa. 9 oil ,LA ENS, No. 706' 7 ° o STATE F ° `ID%gas®fIIIA°�`@ e hNUINCER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P. FLORIDA LICENSE: 38654 Mark R. Dunn P.E. FLORIDA LICENSE: 73968 Joel Falardeau P.E. FLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans & Engineeril Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph# (813)788-5314 Fax# 1-(866)824-7894 E-mail-erb@fbcplans.com W ebsi[e-W ww.ibcplans.com C.OA: #29054 DATE: 1/6/2019 DRAWN BY: TLK REVISION: DATE: RO 1 RO 2 RO 3 RO 4 )Db# 161226 74 PROJECT ADDRESS: 3 DYER RD T ST. LUCIE, FL 34952 ;ONTRACTOR: K & S INDUSTRIES, INC. 1379 SW BILTMORE ST. PORT ST LUCIE, FL 34983 DETAILS S-3 THIS DOCUMENT -- - - —- - I- --- - - - - — - - - OPTIONAL 5" OR 7"-X 0.250" EXTRUDED GUTTER Z-BRACKET 0.250!:j' BRACKET 2' GUTTER BRACKET REQUIRED AT PURLIN ATTACHMENT POINTS w/ (2) #12 X 3/4" SMS INTO GUTTER LIP 1" x 2" x 0.045" OPEN BACK W/(2)#14X 1-1/2" @ ANGLE & (1)#12X 2-1/2" @ 24'� O.C. OR OPTIONAL 2"X2°Xo.04s" PURLIN LAG SCREWS @ FA GUTTER - & (1) @ 12" O.C. MAX- MIN ENT SHALL BE 2" I I THE HOST STRUCTURE SHALL 2" x 2' x Y," X ALUMINUM HAVE AT LEAST A 2"X4' NGLEW/ (4) #12 x3/4" FASCIA AND ROOF TRUSS SMS INTO PURLIN ON EA SYSTEM. CONTRACTOR SHALL SIDE VERIFY THIS AND IF & (4)12X3-1/2" INTO SMALLER- CONTRACTOR GUTTER SHALL BRING STRUCTURE UP TO A 2'X4' FASCIA AND ENSURE LESS THAN A 2'-0" OVERHANG. Al GUTTER BRACKET& PURLIN ATTACHMENT DETAIL S 4 N.T.S. SECONDARY ANGLE MIN - - — - (4) #SO X 3/4" SMS 0.125" THICK (NOT FASTENING SECONDARY REQUIRED FOR 2X3 ANGLE•TO COLUMN MEMBER) EACH SIDE) PRIMARY 2"X 2" OPTION #1 X 0.125" ANGLE TE SCREW1 ANCHOR INTO SECONDARY I (2)#10 X 3/4'SMS FASTENING I COLUMN TO PRIMARY ANGLE 0x 1M'SMS INTO I I OPTION #2 ANGLE(TYP EACH SIDE) (SEE O (TYP EACH SIDE) SCREW BOSSES TABLE) O O 1' X 2" BASE MEMBER =____ (TYP EACH SIDE) — ANCHORSPA (MIN) (TYP)(SEB TABL) (I)- CONCRETE SCREW (SEE 'd TABLE) ANCHOR INTO PRIMARY 2"X2"OR 2"X3' I I 0.062"ALUMINUM INTERNAL OR MEMBER EXTERNAL RECEIVING CHANNEL W/ (4) #10 X3/4" INTO INTO LBEAM OR UPRIGHT. (2) # 14X 3/4" I EALEGINTOGIRTORPURLIN- (0.062" ANGLE CLIPS w/ (2) I #140/4" SMS EA LEG) UPRIGHT OR BEAM -SNAP OR SELF MATING OR HOLLOW PURLIN OR GIRT TO BEAM OR_ POST DETAIL S 4 SCALE: NTS DOUBLE 4" 3/8" 0 x 3" ANCHOR( Column Size 1/4"& 3/8" 0 Concrete Screw Anchor B Min. Spa 2x3-1 4 2x4-1 4 1 2x6-3 4 2X9- 2 IVx1U_j/k5' 1 2 OPTION # 1- A-36 STEEL CLIP MAY BY PLACED ON S. TOPORSIDEOFDECKW/ (2) 3/8"X3" SLEEVE TOP OF ANGSIOR CONCRETE d Q' a a• a' a 2500 PSI CONCRETE W/ OPTION#1 WELDED WIRE OR (4 SLAB ONLY) FIBERMESH ' 0.125" STAINLESS STEEL CABLE 2500 PSI CONCRETE W/ TOP OF rWELDED WIRE OR a l' 4"NOMINAL SLAB d MINIMUM a O Q a ' a 1-1/2'X5-1/2'ALUMINUM OPTION#2 STRAP W/ (2) 3/8 "0 X3" (USE WITH FOOTING) MASONRY ANCHOR (MIN 3-3/4" 1BEDMENT) J1 CABLE TO FOUNDATION CONNECTION DETAIL S_A SCALE: NTS ANGLE AND @ 1/4" 0 CONCRETE 3"(MIN) SCREWANCHOR@ 24' O,C. BETWEEN COLUMNS NOTES: (TYP EACH SIDE) 1. NUMBER OF ANCHORS "B" IS EACH SIDE INTO THE SECONDARY ANGLE AND DOES NOT INCLUDE THE ANCHOR INTO THE 1X2. 2. MINIMUM EMBEDMENT OF ANCHORS INTO CONCRETE FOOTING SHALL BE 2-3/4" AT AT ALL UPRIGHT LOCATIONS. ALL SCREW LENGTHS AT UPRIGHT CONNECTIONS SHALL BE OF SUFFICIENT LENGTH FOR REQUIRED EMBEDMENT INTO CONCRETE FOOTING .° WHEN A PAVER DECK IS PRESENT. 3. CONCRETE SCREW ANCHOR DESIGNS ARE BASED ON THOSE LISTEI ON S-1, D. FASTENERS, OTHER BRAND &TYPE SHALL BE APPROVED BY ENGINEER. 4.2X3W/SX2 CORNER POST SHALL REQUIRE SAME BASE CONNECTIONS AS 2X4 SHOWN IN TABLE. ( \2"x3" OR LARGER UPRIGHT TO CONCRETE W/WO PAVERDETAILS S-4 SCALE:NTS NOTE: WHEN USING OPTION #2 CONNECTION CABLE MUST BE WITHIN 6" OF CORNER OR PRIMARY MEMBER. 1" X 2"X 1/8" ANGLE (4) #12 X 3/4" SMS e e (TYPTOPAND SIDI • WO I \�1/8ELCABTAINLESS LE 3/8" WELDED STAINLESS STEEL EYE BOLT (8) #14 X 3/4 SMS side View 1" 0 (MIN] WASHER BENEATH NUT i Top View • II OPTION #2 5" P� t"A " No. 706 7 -o ^ STATE C F' L A-LORI %,DNA'- ° David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P FLORIDA LICENSE: 38654 Mark R, Dunn P.E. FLORIDA LICENSE: 73968 Joel Falardeau P.E. FLORIDA LICENSE: 70667 Erik Stuart P,E. FLORIDA LICENSE: 77605 FBC Plans & Engineering Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph#(813)788.5314 Fax# 1-(866)824-7894 E-mail-erb@fbcplans.com W ebsite-www.fbcplan s.com C.O.A. #29054 � �Z 1/8"ALUMINUMI PLATE @ 45° DATE: 1 6 2019 ANGLEW/1" I I BREAK 09U- W/ DRAWN BY: TLK 5/16" EYE BOLT W/LOCKNUT& REVISION: DATE: WASHER EA SID rC9)4X3/4 SM RO1 C O.C. RO 2 RO 3 OPTION #3 RO4 '0 ADJUSTABLE EYE T FOR CABLE TENSION O STAINLESS L CABLE PERIMETER FRAMING- 2"X2"X 1/8' EXTRUDED ANGLE ON 45" ANGLE Side View OPTION #1 J2 CABLE CONNECTION AT CORNER S 4 SCALE:NT5 )ob# 18_1226 74 PROJECT ADDRESS: 3 DYER RD T ST. LUCIE, FL 34952 "ONTRACTOR: K & S INDUSTRIES, INC. 1379 SW BILTMORE ST. PORT ST LUCIE, FL 34983 DETAILS S4 DESIGN,