HomeMy WebLinkAboutEVALUATION REPORT►%��%��J - RECEI-VED-- --
V EXTERIOR RESEARCH th DESIGN, I.I.C.
FEB 0420119 Certificate of Authorization #9503
TRINITY 353 Christian Street
ERD ST. Lucie County, Permltting Oxford, CT 06478
(203)262-9245
EVALUATION REPORT
TRI-BUILT Materials Group, LLC Evaluation Report A42970.10.12-R2
PO Box70 FL16027-R2
Rutherford, NJ 07070 Date of Issuance:10/23/2012
(800) s16-1485 CONCEALED cn F MSD PyRevision 2: 09/25/2017
ARE E
SCOPE: bNTRACTOR OR RECORD
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evalu�t�dBfNED f
compliance with the 6th Edition (2017) Florida Building Code sections noted herein. 9
DESCRIPTION: TRI-BUILT Modified Bitumen Roof Systems St. LUcB COUfIty
IABEUNG: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUEDCOMPUANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words 'Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at thejob site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 4, plus a 26-page Appendix. -
—rKESE PLANS AND ALL PROPOSED WORK
Prepared by:
ARE SUBJECT TO ANY CORRECTIONS
,t �•�'•'' ,;.
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
ry?-Re.sa+ea`
COMPLY WITH ALL APPLICABLE CODES.
Robert J.M. Nieminen P.E.
`,°` �• r+
ua�`-a.•`
Tie faom esealavGeari g a,as autlaerked by 0.obercNieminen,
TThhdcesmtsemasanele
Florida Registration No. 59166, Florida DCA ANE1993
.;a,�3
P.LeesonS/3017. vniallysigned
documeac
CERTIFICATION OF INDEPENDENCE:
1. Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest
in any company manufacturing or distributing products it evaluates.
2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or
distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, Is/was used for permitting or design guidance unless retained
specifically for that purpose.
ST. LUCIE COUNTY
PLANS AND PERMIT MUST BE KEPT
SITE OR NO INSPECTION(S) WILL I
1A-1
SA-2
1B
1C
1D
1E-1
1E-2
1F
2A
2B
I —
2C'
Wood
New or Reroof (Tear -Off)
Wood
New, Reroof (Tear -Off) or Recover
Wood
New, Reroof (Tear -Off) or Recover
Wood
New, Reroof (Tear -Off) or Recover
Wood
New, Reroof (fear -Off) or Recover
Wood
New or Reroof(Tear-Off)
Wood
New, Reroof (Tear -Off) or Recover
Wood
New or Reroof (Tear -Off)
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
Steel or Structural concrete
New, Reroof (Tear-Offl or Recover
VTRINITY
A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 4
A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5
B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 5
C Mech. Attached Insulation, Bonded Roof Cover 6
D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 6
E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 7
E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover I g -
F Non -Insulated, Bonded Roof Cover I g +
B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 9
C Mech. Attached Insulation. Bonded Roof Cover i o
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
; 10
3A
Structural concrete
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
1 11-14
3B
Structural concrete
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
1 14
4A
LWIC
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
115-16
4B
LWIC
New or Reroof (Tear -OM
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover'
1 16
4C
LWIC
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover -
1 17-19
-in
wvr
mew or neMOT t r ear-un)
A-1
Bonded Insulation, Bonded Roof Cover .I�.._i
20
5B
CWF
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
21
SC
CWF
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded'Roof Cover
22
-,SD
CWF
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover .3 -' •
22
SE
CWF
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover, G =,
22
6A
Gypsum
. New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
23
6B
_ Gypsum
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof CpVer
24
6C
Gypsum
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover i7 } :+,
24
_ 6D
' Gypsum
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Covet
24
7A
: Various
Recover
A-1
Bonded Insulation, Bonded Roof Cover
25-26 -
- 7B
`_ Various
Recover
F
Non -Insulated, Bonded Base Sheet, Bonded Roof Cover - -
26
-- The following notes apply
to the systems outlined herein:
_
1.
The roof system evaluation herein pertains to above -deck roof components.
Roof decks and structural members shall be In accordance with FBC requirements to fire satisfaction of the Authority Having.lurl4ctlon.
Load resistance of
the roof deck shall be documented through proper codified and/or FBC Approval documentation. ..
2.
Insulation / base sheet fasteners shall be of sufficient length for the following
deck engagement:
D Wood:
Minimum 0.75-inch penetration.
'
➢ Steel:
Minimum 0.75-Inch penetration and engage the top flute of the steel deck.
D Structural concrete: Minimum 1-Inch embedment Into pilot hole In accordance with fastener manufacturers published Installation Instructions.
3.
Unless otherwise
noted, Insulation may be any one layer or combination
of polyisocyanurate,
polystyrene; wood fiberboard, perllte, gypsum -based roof board or mineral -wool
roof board that meets the CIA
requirements of F.A.C.
Rule 61G20-3 and is documented as meeting FBC 1505.1
and, forfoam plastic, FBC Chapter 26, when Installed with the roof cover.
_
Exterior Research and Design, LLC. d/b/a Trinity(ERD Evaluation Report A42970.10.12-R2 for FL16027-R2 `
Certificate of Authorization #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 '
Prepared by: Robert Nleminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-149S Appendix 1, Page i1 of 26
15.
1_u
\! TRINITY
ERD
Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications.
'd5 %.'F:,,}n I 't#i
nr%:�ti',",'al4'ia'As,w1�,',lak+an3,->37,�z�twr'7ABt
1�iRL�UIkTIRUOF,Co1%Bs''°+eT..;
F .. V . 72 }�
m:�+�.,*.`.r}.pr+..,,�x
{ 4. ,
,,"$'"r;r"i
cart. «. ... ...... .. i'ie.. 4i i e.rf.
Reference
layer
Material
Application
BP -AA
Base Ply
FBC Approved ASTM D4601, Type II
(Base and Ply sheets, Asphalt -Applied)
HA at 2040lbs/square
Ply
FBC Approved ASTM D2178, Type IV or VI
SBS-AA
Cap Ply
TriBuilt SBS Granular
HA at 2040 Ibs/square !
(SBS, Asphalt -Applied)
!
-
iSBS'T
Cap PI
-c+M. t;p:.Y. '1=-•-.� I
7'ri6b71CS8SGrandl-- fe
v
(SBS:R'brpti;AppJ...
Y
;• ' II
t.T�o¢rc'M�pple
y=.L�+r r.. '6
SBS-SA
Base Ply
TdBuiIt SASBS Base
- - -'
Self -Adhering I
(SBS, Self -Adhering)
Cap Ply
THBuilt SA SBS Cap
APP-TA
Base Ply or Ply
TriBullt APP Smooth
Torch -Applied
Cap Ply
TriBulit APP Smooth, TriBuil[ APP Granular
(APP, Torch -Applied)
APP-SA
Cap Ply
TriBuilt SA APP Cap
Self -Adhering
(APP, Self -Adhering)
16. Vapor barrier options for use over structural concrete deck followed by adhered Insulation carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MDP listings below vs. those in Table 3A
applies:
y'yyVAPORBAAiIkOPT10Ni:STRUCfURAL'`�Sl(1G4f4QEflf',xA�OHEREU�INSU
Option#
Primer
Vapor Barrier
Insulation Adhesive
MDP(pr sf)
Type
Attach
VB-1.
ASTM D41
TriBuilt SA SBS Base
Self -Adhering
Inta-Stik or CR-20, 12-inch o.c.
-60.0
VB-2.
ASTM D41
TdBuilt SA SBS Cap
Self -Adhering
Insta-Stik, 12-Inch o.c.
-75.0
VB-3.
ASTM D41
TriBuilt SA SBS Cap
Self -Adhering
Millennium One Step Foamable Adhesive, 12-Inch o.c.
-157.5
VB-4.
ASTM D41
TriBullt SA SBS Cap
Self -Adhering
CR-20, 12-Inch o.c.
7270.0
VB-S.
ASTM D41
TdBuilt SA SBS Base
Self -Adhering
Millennium One Step Foamable Adhesive, Millennium PG-1 Pump Grade
Adhesive, OlyBond 50D or CR-20, 12-Inch o.c.
290.0
17. Dens Deck shall be field -primed with PGI00 priorto self -adhering membrane application. Refer to tables herein for other priming requirements.
18. "MDP" = Maximum Design Pressure Is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads.
Exterior Research and Design, U.C. d/b/a Trinity]ERD
Certificate of Authorization #9503 6'a EDITION (2017) FBC NON-HVHZ EVALUATION
Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516.1485
I
I
Evaluation Report A42970.30,12-R2 for FL36027-R2
Revision 2: 09/25/2017
Appendix 1, Page 3 of 26
\! I KINIW J ERD
.,�fi�-�iSk �".sj.,
��Y.s �<y �rsh`�.�w'�Yet,�3�i
2,�WUODgECKS—.NE17VCONiTRUCt10N ERdDFY _FaR`gF�IoG;REco41¢a
,"4 kAAs,,.: ,�,.�,. nn�
,,. a1..ors.n-.:.•�}r2w�.�.C,:Se,»a'�(,ta
Y.ey`idk.�`.5�.u:K,at+4.nn.rl�:.tPt.w."»,^"§,'}�dY/r'f�.._•Y?'f.:+t
,�,'-�SYSTkMTYi!F,E,y�lf�ll`INS,UtA7ED'},rylf�HAIfGAbLY1J1T`,HF,iB,,HWBONbEORtlD'F,1V;R?'•�.�,,�„,,�a;c+�'a{�y�?
nsfv , ^ va
Roof Cover (Note 15)
System
Deck (Note 1)
Base Sheet
MOP
No.
Base
Fasteners
Attach
Base Ply
Cap Ply
i(psf)
Min. inch
Polyglass Elastobase, Polyglass Elastobase
Poly, Polyglass nTeed
OMG Flat Bottom Plates (square) with
12-inch o.c. in 4-Inch lap and 12-Inch
(Optional) One or
)
W 1
od at
plywood at max.
o e MB Base,
Glasbase, Firestone MB Base,1M Per ma-
Roafgrip #14, Hex with Dekfart #14
two, equally spaced, staggered
more BP -AA or
SBS-AA, SBS- .
TA APP TA
52.5
24-Inch spans
Ply 28, Tamko Glass Base or GAFGLAS #75
-3 with
or TruFast MP-3 with TruFast HD
a
center rows
center
APP-TA
W-2
Min. 19/32-Inch
plywood at max.
Polyglass Elastbbase or Polyglass
Dekfast Hex with Dekfasi #14 or TruFast MP-
12-Inch o.c. in 4-Inch lap and 12-Inch
One or more SBS-
SBS-SA, APP-
Elastobase Poly with poly top surface
3 with TruFast HD
o.c, In two, equally spaced, staggered
SA
SA, SBS-TA or
?52.5
24inth spans
center rows
APp TA
W-3
Min. 19/32-inch
plywood at max.
Polyglass Elastobase or Polyglass
OMG Flat Bottom Plates (square) with
12-Inch o.c. in 4-Inch lap and -inch
(Optional) One or
SBS-AA, 5B5-
2 4-Inch
Elastobase Poly
Roafgrip #12
o.c. In two, equally spaced, staggered
more BP -AA or
TA APP-TA
�60.0
spans
center rows
APP-TA
W4
Min. 19/32-Inch
at max.
Polyglass Elastobase or Polyglass
Yg yB
OMG Flat Bottom Plates (square) with
(q )
12-Inch o.c. in 4-Inch lap.and 12-Inch
One or more SBS
SBS-SA, APP-
1
plywood
24-Inchs span
Elastobase Poly with poly top surface
Roofgrip#12
o.c. In two, equally spaced, staggered
SA
SA, SBS-TA or
?60.0•
P
center rows
App-TA
'Y.
*
�� 1i�4. (l..
N''*.iABEe'FsYf)tGICi.+"tlt if+l4 �lf $c U b 1,.,r *y+'r° '•(e �"' t? "'
Ottt.,F )7 P� miElt(Jp R 1 a x
}(r+5�,5I�C. "'#"K�'Ye✓Ft. �erttURtiL..�tiA ..N-!,..,�S.8A4`_.Y,^r ..f... .a..h�:i 4wMFa qg���`5 �.. ��ti� ���?Y�,.
1
ir,,.
�`L'
System
Deck
Primer
Roof Cover (Note 15)
'MOP
Joint Treatment
Base Ply
Ply
Cap Ply
No.
(psf)
W-5
Min. 15/32-inch plywood
at max. 24-Inch spans
(Optional) ASTM D41
None
SBS-SA
(Optional) SBS-SA or
APP-TA
SBS-SA, APP-SA, SBS-TA
I or APP-TA-90.D
W 6
Min. 15/32-Inch plywood
at max. 24-inch spans
(Optional)ASTM D41
Plywood Joints are covered with 4-Inch wide strips of TriBuilt SA
SBS Base, rolled Into place to create continuous bond.
TriBullt SA SBS Base
(Optional) SBS-SA or
qpp-TA
SBS-SA, APP-SA, SBS-TA
of APP-TA
-97.5
Exterior Research and Design, U.C. d/b/a TrmIty) ERD
Certificate of Authorization #9503
Prepared by: Robert Meminen, PE-59166
e EDITION (2017) FBC NON-HVHZ EVALUATION
TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485
Evaluation Report A42970.30.12-R2 for FL16027-R2
Revision 2: 09/25/2017
Appendix 1, Page 8 of 26
�4
\NTINITYERD
REPORT
FEB 0 4 2019
ST. Lucie Co'inty,
OR RESEARCH & DESIGN, LLC.
Cert1ficote of Authorization 19503
353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
(203)262-9245
Owens.CEirning Evaluation Report 037940.02.12-RB
One Owens CorningPerkw LE COPY FL30674-R33
Toledo, OH 43659 Date of Issuance: 07/06/2012
(740) 404-7829 ^i/ 1q Revision 8: 10/09/2017
SCOPE: _I �%I � l 1 61— BO
This Evaluation RRftport is issued under Rule 61G20-3 and the appftcable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6tb Edition (2017) Florida Building Code
sections noted herein.
DEscRIPnoIv '7Ow C rnrigAseha"It Roof=Sti ngles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1 / R905.2.6.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words `Trinity] ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user_by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
The Facsimile seal appearing was authorized by Robert
Nieminen, P.E. on 10/09/2017. This does not serve as an
electronically signed document
CERTIFICATION OF INDEPENDENCE:
1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, Is/was used for permitting or design guidance unless retained
specifically for that purpose.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
V IRININ ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated
compliance with the following sections of the 6`h Edition (2017) Florida Building Code and Florida Building Code,
Residential Volume through testing in accordance with the following Standards. Compliance is subject to the
Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS: '
Section
Property
Standard
Year
1507.2.5, R905.2.4
Physical Properties
ASTM D3462
2010
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D3161
2016
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D7158
2011
3. REFERENCES:
Entity
Examination
Reference
Date
UL LLC (CER9626)
Physicals & Wind Resistance
File R2453, Vol.3
02/15/2007
UL LLC (CER9626)
Physicals & Wind Resistance
20120516-R2453
05/16/2012
UL LLC (TST9628)
Physical Properties
06CA20263
04/18/2006
UL LLC (TST9628)
Wind Resistance
11CA34308
02/18/2012
UL LLC (TST9628)
Physicals & Wind Resistance
4786093137
02/01/2014
UL LLC (TST9628)
Wind Resistance
4786126532
02/10/2014
UL LLC (TST9628)
Physical Properties
Classification letter
02/13/2014
UL LLC (TST9628)
Physical Properties
Classification letter
10/02/2015
Miami -Dade (CER1592)
FBC HVHZ Compliance
Various NOAs
Various
UL LLC (QUA9625)
Quality Control
Service Confirmation
Exp. 05/16/2020
4. PROOucr DESCRIPTION:
4.1 Asphalt Shirfkles '
4.1.1 Classic and Supreme are fiberglass reinforced, 3-tab asphalt roof shingles.
4.1.2 Berkshire are fiberglass reinforced, 4-tab asphalt roof shingles.
4.1.3 Devonshirem are fiberglass reinforced, 5-tab asphalt roof shingles.
4.1.4 Duration, TruDefinition Duration, Duration Premium Cool, TruDefinition Duration Designer Color
Collection, TruDefinition Oakridge, Oakridge and WeatherGuarde HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 His) & Ridge Shingles:
4.2.1 Berkshire Hip & Ridge Shingles, High Ridge, WeatherGuard HP Hip & Ridge Shingles, ProEdge Hip & Ridge
Shingles and Duraltidge'" Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles.
4.3 Accessory Starter Strips:
4.3.1 Starter Strip Shingle, Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZjurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-118
rerVpscte o)Authoriwtion"S03 6'EDITION (2D17)FBC NON-HVHZEVALUATION F1.30674-1133
Owens Coming Asphalt Roof Shingles Revision 8: 10/09/2017
Page 2 of 8
4-
- - - \JI R1N1V ERD
5.4 Wind Classification:
5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable
for use in all wind zones up to Vaal = 150 mph (V h = 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip -Shingle and Starter Strip Plus noted herein are
Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D31611 Class F, indicating the
shingles are acceptable for use in all wind zones up to V„d =150 mph (Vuil =194 mph). Refer to Section 6 for
installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean
roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3.
6. INSTALLATION:
6.1 Underiavment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval, or be Locally Approved per Rule 61G20-3, per FBC 1507.2.3,1507.2.4 or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following
exceptions:
➢ Berkshire shingles require minimum five (5) nails per shingle.
➢ WeatherGuare HP shingles require minimum six (6) nails per shingle.
➢ Devonshire'" shingles require minimum six (6) nails per shingle.
➢ Starter Strip Shingle and Starter Strip Plus require minimum five (5) nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
2507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing —Starter Strip Shingle and Starter Strip Plus:
Exterior Research and Design, L.I.C. Evaluation Report 937940.02.12-Rg
Certificate ofAuthedzotion Mail Sn'EDITION (2017)FeC NON-HVHZ EVALUATION FL10674-R13
Owens Coming Asphalt Roof Shingles Revision 8: 10/09/2017
Page 3 of 8
6.2.6 Minimum Nailing —Classic®&Supreme:
Wind Am& High 111flad
A1w pan rbnfow nwmam Ar wbneu / g
Fe,Wo.urn ' t
FwOosfoidn
6.2.7 Minimum Nailing —Berkshire®:
1•
SaabrtsWp
412a4aa640o
Standard Fastenine Pattern
�l TRINITY ERD
Normal
Am js�
bgh «
AnilPmwbnfowo bw Anws vbnmw Orereas
I--4•—L.—L_J t•
E 6/6',E>paun
E>wcgeldn
Exterior Research and Design, U.C.
Cer0fnwte ofAutharbodon 49503 6`"EDITION (2017)FBC NON-HVHZ EVALUATION
Owens Coming Asphalt Roof Shingles
6olunawip
4dnMaWdar
Vi' I a k" I 8lh• ' 8 Lh• 1•
G-Nail Fastening Pattern
Evaluation Report 037940.02.12-R8
FL30674-R33
Revision 8:10/09/2017
Page 4 of 9
ERD
TRINITY
6.2.8 Minimum Nailing—Devonshirerm:
5bl5' exposure
B�osWiinde5b/8pplg
UblrsddndidsdWw
IIIIeM
Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern
6.2.9 Minimum Nailing — Duration®, TruDefinitionO Duration, Duration® Premium Cool & TruDet3nition
Duration Designer Color Collection:
. atla0 Fastening PeBarn
ns.xaro�aaaimp
M%mm
r +r m
Standard Fastening Pattern
Mansard or Steep Slope Fastening Pattern
6-Nail Fastening Pattern
Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-R8
Cerdficate ojAuthorizoRon 09503 CH EDITION (2017) FBC NON-HVHZ EVALUATION FL30674-R13
Owens Coming Asphalt Roof Shingles Revision 8: 10/09/2017
Page 5 of 8
6.2.1 Minimum Nailing—TruDefinition`OakridgeO,OakridgeO:
'd Nail Rattan
FSgvenv im/dams,
Standard Fastening Pattern
r—
�l TRINITY I ERD
&.Nall Pdturn
EspozIa=Sdaws
r
Ir Q
661a"Ew 0�6 66I6"Egiosvw
B�fi[snQa66lapdg Fiporfd5eds66/Bpog
Mansard or Steep Slope Fastening Pattem
6.2.1 Minimum Nailing —WeatherGuard® HP:
6-Nail
�. 7• -_�� 7 ajdE�iYl� VIII�
e i:..:ar :� iLi(isrt7Yws�sFlYYw
ming Pattern
Exterior Research and Design, U.C. Evaluation Report 037900.02.12-118
Cerdprote ofAuthorimdon a9503 6ry EDITION (2017) FBC NON-HVHZ EVALUATION FL10674R13
Owens Coming Asphalt Roof shingles Revision 8: 10/09/2017
Page 6 of 8
\, TRINITY ERD
6_3 Hip & Ridge Shingles:
6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuard HP Hip and Ridge Shingles
and Pro Edge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions,
using four (4) nails per shingle. Installation of DuraRidge'm Hip & Ridge Shingles shall comply with the
Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning
published information on wind resistance and installation limitations, including the use of hand -sealing for
wind warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing — Berkshire® Hip & Ridge and High Ridge:
6.3.4 Minimum Nailing — WeatherGuard® HP Hip and Ridge:
Fig. A
v,anmgebo
�—alntlbn' -
MW
Fig. C Hip & RldgeShingle Fastening
neg�a.
tape WQ3
r
a• 2•
p 1•
-r 1
s nyawn
Exterior Research and Design, U.C.
Certfflmt"fAu05oritatlon#9503 6mEDITION (2017)FBC NON-HVHZ EVALUATION
Owens Coming Asphalt Roof Shingles
Evaluation Report 037940.02.12-118
FL10674-R13
Revision 8: 10/09/2017
Page 7 of 8
21
6.3.5 Minimum Nailing - ProEdge Hip & Ridge Shingles:
Pnvafiing
Wind DirOCdon Su4nt 8trlp
,, I MITY ERD
Stendard
FFassUUnMB
* hI r
368but
lye'
6.3.6 Minimum Nailing— DuraRidgeTM Hip & Ridge Shingles:
Note: The drawings below pertain to minimum, as -tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1 / R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named CA entity for information on which plants produce products covered by Florida Rule 9N-3 CIA
requirements.
10. QUALiTYAssURANCEENTRY:
UL LLC—QUA9625 ; (631) 546-2458; Kanchi.Agrawala-Dokania@ul.com
- END OF EVALUATION REPORT-
Exterior Research and Design, U.C. Evaluation Report 03794D.02.12-Rg
Certificate ofAuthorkadon p9503 eEDITION (2017)FBC NON-HVHZ EVALUATION FL30674-R13