HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017S Cn DV
FLORIDA ENERGY EFFICIENCY O 1¢LC17 N CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: SMITH ADDITION
Street: 6105 PINE TREE DRIVE
Builder Name: VAN WAL HOMES, INC.
Permit Office: ST. LUCIE COUNTY
SCANNED
City, State, Zip: FT. PIERCE, FL,
Permit Number.
By
Owner: WILLIAM SMITH
Jurisdiction: ST. LUCIE COUNTY
St. Lucie
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate
Zone 2) County
1. New construction or existing Addition
9. Wall Types(320.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Frame - Wood, Exterior
R=13.0 320.00 ft'
b. N/A
R= ft'
3. Number of units, if multiple family 1
c. WA
R= k
4. Number of Bedrooms(Bedrms In Addition) 0(0)
d. N/A
R= k'
5. Is this a worst case? No
10. Ceiling Types (204.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 204.00 ft'
6. Conditioned floor area above grade (W) 204
b. WA
R= ft'
Conditioned floor area below grade (W) 0
c. WA
R= ft'
11. Ducts
R ft'
7. Windows(52.8 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 40
a. U-Factor: Dbl, U=0.65 40.00 ft'
SHGC: SHGC=0.25
b. U-Factor: Dbl, U=0.65 12.83 ft'
12. Cooling systems
kBtulhr Efficiency
SHGC: SHGC=0.30
a. Central Unit
42.0 SEER:14.00
c. U-Factor. N/A ft'
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor. N/A ft'
a. Electric Strip Heat
34.0 COPA.00
SHGC:
Area Weighted Average Overhang Depth: 2.000 ft.
Area Weighted Average SHGC: 0.262
14. Hot water systems - None required
8. Floor Types (204.0 sqft.) Insulation Area
a.
Cap: N/A
a. Raised Floor R=30.0 204.00 ft'
b. Conservation features
EF: 0.000
b. N/A R= ft2
c. N/A R= ft'
15. Credits
CF, Pstat
Glass/Floor Area: 0.259 Total Proposed Modified Loads: 9.62
PASS
Total Baseline
Loads: 9.98
1 hereby certify that the plans and specifications covered by
Review of the plans and
SHE STgj�
this calculation are in compliance with the Florida Energy
specifications covered by this
OF
Code.
calculation indicates compliance
yttl ii„
with the Florida Energy Code.
PREPA By:
DATE:
Before construction is completed
this building will be inspected for
r O
O y
compliance with Section 553.908
* °
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
!)
with the Florida Energy Co
GOp WE L¢�
��
�-�
OWNER/AGENT: I 1
BUILDING OFFICIAL:
DATE: 9 is - t ti
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R 0
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
MAR S 2019
Permitting Department
2/26120197:56 AM EnergyGauge®USA Section R405.4.1 Compliant Software St. Lucie COUP-f;; I-L
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
•
PROJECT
- Title7
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
SMITH ADDITION - - —Bedrooms: 0
User Conditioned Area: 204
WILLIAM SMITH Total Stories: 1
1 Worst Case: No
VAN WAL HOMES, INC. Rotate Angle: 0
ST. LUCIE COUNTY Cross Ventilation:
ST. LUCIE COUNTY Whole House Fan:
Single-family
Addition
Address Type: Street Address
Lot #
Block/Subdivision:
PlatBook:
Street: 6105 PINE TREE DRIV
County: St. Lucie
City, State, Zip: FT. PIERCE,
FL,
CLIMATE
/
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39 90
70 75 299 62 Low
BLOCKS
Number
Name
Area Volume
1
Blockl
204 1632
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms Infil ID Finished Cooled Heated
1
ADDITION
204 1632 No 1
1 Yes Yes Yes
FLOORS
#
Floor Type
Space R-Value
Area Tile Wood Carpet
1 Raised Floor
ADDITION — —
204 ft' 30 0 0 1
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Solar SA Emitt Emitt Deck Pitch
Absor. Tested Tested Insul. (deg)
1
Hip Composition shingles 221 ft' 0 ft' Medium
0.6 No 0.9 No 0 22.6
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 150 204 ft' N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
ADDITION 30 Blown
204 ft' 0.11 Wood
2/26/2019 7:56 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
-
Adjacent - -- -
apace Caviy — t-Width Height Sheathing Framing Solar Belo w
—1 N
2 E
3 W
Exterior Frame - Wood
Exterior Frame -Wood
Exterior Frame - Wood
ADDITION 13 20 8 160.0 ft' 0 0.25 0.6
ADDITION 13 10 8 80.0 ft' 0 0.25 0.6
ADDITION 13 10 8 80.0 ft' 0 0.26 0.6
0
0
0
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
V #
Wall
Ornt ID Frame Panes
Overhang
NFRC U-Factor SHGC Imp Area Depth Separation Int Shade
Screening
1
2
N 1 Metal Low-E Double Yes 0.65 0.25 N 40.0 ft' 2 ft 0 in 1 ft4 in Drapeslblinds
W 3 Metal Low-E Double Yes 0.65 0.3 N 12.8 ft' 2 ft 0 in 1 ft 4 in Drapesiblinds
None
None
INFILTRATION
# Scope
Method
SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000356 190.4 10.45 19.66 .2678 7
HEATING SYSTEM
#
System Type
Subtype Efficiency Capacity Block
Ducts
1
Electric Strip Heat/Existing/co
None COPA 34 kBtu/hr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit/Supplemental for
None SEER: 14 42 kBtu/hr 1260 cfm 0.85 1
sys#1
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
ft'
DUCTS
/
V #
— Supply—
Location R-Value Area
— Return — Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT ON RLF
HVAC #
Heat Cool
1
Attic 6 40 ft'
Attic 10 ft' Default Leakage Attic (Default) (Default)
1 1
2/26/2019 7:56 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 4
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
- Programabltre�,Thermostatt:: Y- -
--
Cffei]]ling Fans: - -
-
-
Coollng Janr[X,]
Venting
Mar
Mar
Apr
May
Jun
�X-
[ Jul
[ ]
[X] Aug
[X]
] Sep
[ ]
L 1 r[X,]
Nov
Dec
rt-)C,)
Dec
[ j Jan
[ ]Feb
[X]
[
]
Jun
I Jul
[ ]Aug
E ]Sep
Lxl Octct[X]
[ ]
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s
.ft.
0 ft'
0 ft
0.3
ADDITION
Name:
Rating Compant:
Date: a-0-Cp- -As
2/26/2019 7:56 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 4
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER -AND -INSULATION -INSPECTION COMPONENT CRITERIA
Project Name: SMITH ADDITION Builder Name: VAN WAL HOMES, INC.
Street: 6105 PINE TREE DRIVE Permit Office: ST. LUCIE COUNTY
City, Stale, Zip: FT. PIERCE, FL, Permit Number.
x
U
Owner: WILLIAM SMITH Jurisdiction: ST. LUCIE COUNTY
w
x
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in an dropped ceiling/soffit
y
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
a. In addition, inspection of log walls shall be in accordance with the provisions of [CC-400.
2/26/2019 7:57 AM EnergyGaugeO USA FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 96
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. Addition
12. Duds, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location AttictAttic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
0
13. Cooling system: Capacity
42.0
a) Split system SEER
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
204
d) Room unit/PTAC EER
e) Other
14.0
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.650
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.262
14. Heating system: Capacity
34.0
c) Area
7c.
52.8
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
b) Wood, raised (R-value)
9b.
30.0
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
13.0
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
0 Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
Yes
a) Under attic
11a.
30.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
0 Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not
I certify that this home has complied with the Florida Building Code, Energy Conservation, through tl
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise,
display card will be completed based on installed code compliant features.
Builder Signature 115 -W ':�d
J--at9- I
Address of New Home: 6105 PINE TREE DRIVE City/FL Zip:
k
MAR S 2019
armittinq Departm,
St. Lucie County, F
2/26/2019 7:56:59 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
+ wrightsoft• Project Summary o te,
Entire House BT.
QUICK-CALCS, INC.
317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phore: 772-466-6799 Emit: OUICKCALCS@AOL.COM
For. WILLIAM RSMITHADDITION
6105 PINE TREE DR., FT.. PIERCE, FL
Notes:
Weather. Fort Pierce, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db
42
OF
Outside db
90
OF
Insidedb
70
OF
Insidedb
75
OF
Design TD
28
OF
Design TD
15
OF
Daily range
M
Relative humidity
50
%
Moisture difference
61
gr4b
Heating Summary
Sensible Cooling Equipment Load
Sizing
Structure
15357
Btuh
Structure
21476
Btuh
Duds
6145
Btuh
Ducts
8769
Btuh
Central vent (0 ctm)
0
Btuh
Central vent (0 cfm)
0
Btuh
none
(none)
Humidification
0
Btuh
Blower
0
Btuh
Piping
0
Btuh
Equipment load
21502
Btuh
Use manufacturer's data
n
Rate/swin multiplier
0.95
Infiltration
Equipment sensible load
28733
Btuh
Method
Simplified
Latent Cooling Equipment Load Sizing
Construction quality
Average
Fireplaces
0
Structure
3095
Btuh
Duds
2561
Btuh
Central vent (0 cfim)
0
Btuh
Area(fl2)
Heating
Coolingg
(none)
1831
1831
Equipment latent load
5655
Btuh
Wlume
16479
16479
Airchan�ge�sthour
Equiv.AVF
0.38
020
Equipment Total Load ((Sen+Lat)
34388
Btuh
(ctm)
104
55
Req. total capacity at 0.70 SHR
3.4
ton
Heating Equipment Summary
Cooling Equipment Summary
Make
Make Heil
Trade
Trade EXISTIG
SYSTEM
Model
Cond R4A448GKA10
AHRI ref
Coil ENA4X48L21A1+G9MVE0801716AA1
AHRI ref
Efficiency
100 EFF
Efficiency 12.0 EER,14 SEER
Heating input
6.4
kW
Sensible cooling
29400
Btuh
Heating output
21953
Btuh
Latent cooling
12600
Btuh
Temperature rise
50
OF
Total cooling
42000
Btuh
Actual airflow
400
ctm
Actual airflow
1400
cfm
Airflowfador
0.019
chit tuh
Air flow factor
0.046
dim/Btuh
Static
pressure
0.50
in H2O
Static pressure
0.50
in H2O
Space thermostat
Load sensible heat ratio
0.84
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
_ Ad- wrightsotC 201&Feb-2607.4937
•.•- RigflSUriverm1201919.0.01 RSU09101 Pagel
...CKDoa rls%Wrigtl»ftWACLSMrrH,WILLIAMnp CaIc=M16 FrortOoorfaces NE
Wrightsoft' Right-M Worksheet Job:
Entire House pate:
ar
QUICK CALCS, INC.
317 ST. LUCIE LANE, FORT PIERCE, FL34M Phore: 772-466-6799 Email: QUICKCALCS@AOL.COM
1
2
3
4
5
Roan name
Fed vsll
Rcan fleigM
Roan dimensore
Roanarea
Errore Home
240.0 ft
9.0 It
1831.0 ft'
f-)WASt
144.0 ft
9.0 a heatcnd
41.0 x 31.0 ft
1271.0 ft'
Ty
CoshxDon
number
U-wlue
(BhHf2-°F)
Or
HTM
(Btuhfi2)
Area (f2)
or perimeter (fl)
Loci
(Bluh)
Area (M
or perimeter (fl)
Load
(Bfuh)
Heat
Cod
Gros
NrPfS
Heat
Cod
Gras
NrP)S
Heat
Cod
6
11
�-D
12C-0
4A5-20b
JlD0
12C4)W
4A5-20b
4A54ob
12GOsv ,
4A540b 't
4A5-2ob
4A5-20,A
12C-Ow
4A5-2ob
4A5-2ad
0.091
0.560
ne
ne
_he.
s
6e
se
Sv
w
sv
-sv.
nw
m+
mw
255
15.68
1.96
33.75
10.34.
549
60
466
0
1192
941
229
918
2025
21721
369
60
288
0
-21
239
0
20
287
0
0
30
239
0
0
- 734
941
-,_.229
609
0
627
732
0
0
1074
609
627
0
563
2025
-217.
468
0
1006
'-562
0
0
,1881.
468
1350
0
�G
�C
_0.390
0.091
0.560
0.560
-0.091
0.560
0.560
-0.470
0.091
0.560
0_470
_10.92
255
15.68
15_68
2.55
16.68
15.68
13,16
255
15.68
13.16
1.96
16.16
2.5.15_
" 1.96
25.15
25.15
23.05
1.96
33.75
2829
_21
531
13
40
549
20
20
-82
631
40
54
-21
478
13
20
426
- 10
10
____30
437
0
0
1218
204
627
1090
307
314
1074
1112
627
716
935
210
1006
837
493
603
`1881
am
1350
1539
279
0
40
9 9
0
0
�82
279
40
0
_
T�
C_
F_
F
_16s3-mR
19A-30bam
-1W30bsp
=O.b32
0.034
=MW
-
_0.90
1.60
wi-
1271
_200
=1414147,1.
=1318
1015
_160
_2354
544
_86
911
1_271
= 911
1271
=Cis
=1458
544
-
=
0.80
=0.80
0.43
=0:43
1271
=20b
-�- 0
=0
_1015
0
_ o
6
C) AED a waon
1903
721
Emelope lossIgain
12145
17651
8014
11262
12
a) Infiltration
b) Room %entilatim
3212
0
906
0
1927
0
543
0
13
lnbmd gains Osirpanfs@ 230
Applanomk2w
4
920
20001
4
9m
2000
Subk:lal Qirxs6to13)
15357
21476
9941
14725
14
15
Lesademalload
Lestansfer
Redstibutian
Subtlal
Dudloads
40°h
41%
0
0
0
15357
6145
0
0
0
21476
8769
40%
41%
0
0
0
9941
3978
0
0
0
14725
6012
Totalroan load
Air requiretl(Qm)
21502
400
30245
1400
13919
259
20737
960
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
wrightsoit- 2019-Feb-2607A937
A&I Rigf-SUte9Uriwema1201919.0.01 RSLI08101 Page l
-.CKOOa r&WrigNmftWAC%SMrn4.WILLIAMnp Calc=MIB Frort Doorf w&NE
+ vdrightsoft' Right-M Worksheet Job:
Entire House Date:
sy:
QUICK CALCS,-INC.
317 ST LUCIE LANE, FORT PIERCE, FL34946 Phone: 772466-6799 Email: QUICKCALCS@AOLCOM
1
2
3
4
5
Roan name
Exposed%Wl
Ram height
Room dimensions
Roan area
EXIST MASTER
56.0 it
9.0 it heaVmol
20.0 x 18.0 8
360.0 fe
NEWWIC
16.0 It
9.0 a heaVond
6.0 x 10.0 it
60.0 it
Ty
Cordon
number
U-value
(SWh4l2_*q
Or
HTM
(BWh4n
Area (1F)
a perimeter (ft)
Load
(BWh)
Area (IF)
or perimeter (ft)
Load
(BWh)
Heat
I Cod
Gross
N/P/S
Heat
Cool
Gros
WP/S
Heat
Cod
6
11
12C-0sv
4A5-20b
1100
12C-Ow
4AS2ob
4AS20b
12C-DS
4A5-2ob
4AS2ob
4A5-.2M
12C-Ow
4A5-2ob
4AS-2md
168-30ad
19AJ0bsm
19AJObsp
0.091
0.560
,_0,390
0.091
0.560
0.560
0.091
0.560
0.560
_0.470
0.091
Os60
0.470
ne
ne
ne-
se
se
se
sv
sv
sv
9N-
m
nw
mx
255
15.68
-11.96
33.76
1C
0
180
0
459
0
352
0
0
0
0
- 0
0
0
0
6
0
0
�G
I--G
_10.92
255
15.68
15_68
255
15.68
15.68
13.15
255
15.68
13.16
_10.34
1.96
16.16
2515.
1.96
25.15
25.15
_,23.05
1.96
33.75
2829
-0
162
0
0
______0
162
0
0
-0
413
0
0
317
0
0
-0-0-0
0
0
0
0
0
0
0
0
0
0
0
0
"0
0
0
0
0
0
- 0
0
0
0
0
0
0
54
0
0
0
64
0
0
138
0
0
106
0
0
I�
V1/
I�-GG
C`
F
�F_
„0
162
0
54
_____`0
108
0
0
-0
274
0
716
v323
0
211
0
1539
90
0
0
-0-0
90
0
0
229
0
0
-0.
176
0
0
_0032
0.034
_0.034
-
=.
_0.90
, 0.80
�0.80
1.80
�0.43.
-�0.43
_360.
=360
0
i0
=576
0
60
0
_60
_60
0
=60
-9
0
! 96
0
=25
�0
_0
0.
0
=748
6
c)AED e=rson
632
0
Envelope loss/gain
2184
36W
469
403
12
a) Witation
b) Room ventilation
749
0
211
0
214
0
60
0
13
Internal gains OOawnls@ 230
Appliarces/dher
0
0
0
0
0
0
Subblal Qines6 to 13)
2933
3838
683
464
14
15
LesseAmalload
Lestansw
RedisnGNon
Subtotal
Dudloads
40%
41%
0
0
0
29M
1174
0
0
0
3838
1667
40%
41%
0
0
0
663
273
0
0
0
464
189
Trial room load
Airrequired(dm)
4107
76
5405
250
956
18
653
30
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
_ - wrighisoit- 2019-Feb2607:4937
RigFRSdte®thiMM1201919.0.01 RSU08101
.9C P....CKrpoamerls\WdgttsoftWACSMrrH,WILLt4Mnp CaIc=MJ8 FmnDoorfaees NE Paget
wrightsoft• Right- J® Worksheet Job:
Entire House pale:
QUICK CALCS,-INC. By
3175L LUCIE LANE, FORTPIERCE, FL34946 Phone: 772466-6799 Email: OUICKCALCS@AOL.COM
1
2
3
4
5
Rocm name
Flposedmdl
Rc height
Room dimere
Roomarea
NEWSIITING
24.0 It
9.0 It heaVmd
14.0 x 10.0 It
140.0 ft'
Ty
Cmstrlxtion
number
U-value
(BWh@i°F)
Or
HTM
(BIJAV)
Area (M
a pedmehx (ft)
Load
(BhWh)
Area
a perimeter
Load
Heat
Cod
Gross
NOS
Heat
Cool
Grass
NIPS
Heal
Cool
6
Tfc 0
4AS201b
,1100
0.091
0.560
_0.390
ne
ne
-ne.
Z55
15.68
10.92
- 1.96
33.75
`10.34
0
0
—0
0
0
0
0
0
0
0
0
0
11
�1
I--(i
�G
12C-0av
4AS20b
4A5-2ob
12C-0sx
4A5-20b
4A5-20b
4A5-2oW
12C-OW
4AS2ob
4A5-2oW
188 30ad.
19A-30bSw
JW30tx
0.091
0.560
0.560
0.091
0.560
0.560
—0.470
0.091
0.560
0.470
`0.032
6e
M
se
sv
w
w
_w,
M
nw
w
255
15.68
15.68
265
15.68
15.68
_1316
255
15.68
13.16
1.96
16.16
25.15
90
13
0
77
13
0
196
204
0
151
210
0
�—G
1.98
25.15
25.15
_23.05
1.96
33.75
2829
125
20
20
- 86
10
10
220
307
314
169
493
503
0
I—C
4)/
_0
0
0
0
—0
0
0
0
_0
0
0
0
0
0
0
C_
F
.F=
=.
—0.—
0.80
_0.80
11.60
0_43
=140
0
140
- 40
0
=125
0
112
1224
0
0.034
10.034
-
,d0.43
=140
=60
6
c)AEDaa uson
550
Ern Lope loss/gain
1478
2359
12
a) Infiltration
b) Rcom %entilatm
321
0
91
0
13
IMemal gains Oaalpants@ 230
Appliarc s(dher
0
0
0
Subbla Qms6to13)
1799
2449
14
15
Lewwte alload
Lesstrarsfer
RecrisbibiAw
SubN1al
Cludloads
40%
41%
0
0
0
17%
720
0
0
0
2449
1000
Total mom load
Air required (dm)
I
1
2519
47
34W
160
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
-FW =191 sort- 2013Feb2607:4937
AC k RighISdte®Udve=1201919.0.01 RSU08101 Page
-.CKIDo rtslWdgttsoftWACGMRH,WILLIAMnp Catc=MB FmrtDoorfaees NE
Duct System Summary Job:
wrightsoft y ry Dale:
_ _Entire House B_T.
QUICK CALCS, INC.
317 ST. LUCIE LANE, FORT PIERCE, FL34946 Ptcm: 772-466-6799 Emil: QUICKCALCS@AOL.COM
For. WILLIAM R SMITH ADDITION
6105 PINE TREE DR., FT. PIERCE, FL
External static pressure
Pressure losses
Available static pressure
Supply / return available pressure
Lowest fiction rate
Actual air flow
Total effective length (TEL)
Heating
0.50
in H2O
0
in H2O
0.50
in H2O
0.250 / 0.250
in H2O
0.080
in/100ft
400
cfnT
103 ft
Cooling
0.50
in H2O
0
in H2O
0.50
in H2O
0.250 / 0.250
in H2O
0.080
iN100ft
1400
cliin
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FIR
Diam
(in)
HxW
(in)
Dud
Mat!
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
EISRMASTER
C 2703
38
125
0.080
8.0
Ox0
VIFx
0
0
E)GSITMASTER-A
C 2703
38
125
0.080
8.0
Ox0
VIFx
0
0
EXST19
C 3457
43
160
0.080
9.0
Ox0
VIFx
0
0
EXST1e-A
C 3456
43
160
0.080
9.0
Ox0
VIFx
0
0
ExsT.tz-6
C 3456
43
160
0.080
9.0
Ox0
VIFx
0
0
EXSTASIC
C 3456
43
160
0.080
9.0
Ox0
VIFx
0
0
ExsT.lst-o
C 3456
43
160
0.080
9.0
Ox0
VIFx
0
0
EXST.1sFE
C 3456
43
160
0.080
9.0
Ox0
VIFx
0
0
NEWSITING
C 3450
47
160
0.080
8.0
Ox0
VIFx
11.7
90.0
st1
NEW WIC
C 653
18
30
0.080
5.0
Ox0
VIFx
12.9
90.0
st1
Name
Trunk
Type
Htg
(Crm)
Clg
(dm)
Design
FIR
Meloc
(fpm)
Diam
(in)
H x W
(in)
Dud
Material
Trunk
st1
PeakAVF
65
190
0.080
348
10.0
0 x 0
VInIFIX
Return Branch Detail Table
Name
Grille
Size (in)
Htg
(dm)
Clg
(dm)
TEL
(ft)
Design
FR
Meloc
(fpm)
Diam
(n)
H x W
(in)
Stud/Joist
Opening (in)
Dud
Mat!
Trunk
rb1
Ox0
400
1400
0
0
0
0
Ox 0
VIFx
Wrightsof l 2019-Feb2607.57:36
+ •.•+-..v.�, NgIVSute4DUriv =1201919A.01 RSU06101
Page 1
ACCI\ _CK1DoamertslWngttsoR HVAClSM1rH, WILLIAMnq CaIc=MI6 Fort Door faces NE