Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017S Cn DV FLORIDA ENERGY EFFICIENCY O 1¢LC17 N CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: SMITH ADDITION Street: 6105 PINE TREE DRIVE Builder Name: VAN WAL HOMES, INC. Permit Office: ST. LUCIE COUNTY SCANNED City, State, Zip: FT. PIERCE, FL, Permit Number. By Owner: WILLIAM SMITH Jurisdiction: ST. LUCIE COUNTY St. Lucie Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2) County 1. New construction or existing Addition 9. Wall Types(320.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Frame - Wood, Exterior R=13.0 320.00 ft' b. N/A R= ft' 3. Number of units, if multiple family 1 c. WA R= k 4. Number of Bedrooms(Bedrms In Addition) 0(0) d. N/A R= k' 5. Is this a worst case? No 10. Ceiling Types (204.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 204.00 ft' 6. Conditioned floor area above grade (W) 204 b. WA R= ft' Conditioned floor area below grade (W) 0 c. WA R= ft' 11. Ducts R ft' 7. Windows(52.8 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 40 a. U-Factor: Dbl, U=0.65 40.00 ft' SHGC: SHGC=0.25 b. U-Factor: Dbl, U=0.65 12.83 ft' 12. Cooling systems kBtulhr Efficiency SHGC: SHGC=0.30 a. Central Unit 42.0 SEER:14.00 c. U-Factor. N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft' a. Electric Strip Heat 34.0 COPA.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.262 14. Hot water systems - None required 8. Floor Types (204.0 sqft.) Insulation Area a. Cap: N/A a. Raised Floor R=30.0 204.00 ft' b. Conservation features EF: 0.000 b. N/A R= ft2 c. N/A R= ft' 15. Credits CF, Pstat Glass/Floor Area: 0.259 Total Proposed Modified Loads: 9.62 PASS Total Baseline Loads: 9.98 1 hereby certify that the plans and specifications covered by Review of the plans and SHE STgj� this calculation are in compliance with the Florida Energy specifications covered by this OF Code. calculation indicates compliance yttl ii„ with the Florida Energy Code. PREPA By: DATE: Before construction is completed this building will be inspected for r O O y compliance with Section 553.908 * ° I hereby certify that this building, as designed, is in compliance Florida Statutes. !) with the Florida Energy Co GOp WE L¢� �� �-� OWNER/AGENT: I 1 BUILDING OFFICIAL: DATE: 9 is - t ti DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R 0 envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). MAR S 2019 Permitting Department 2/26120197:56 AM EnergyGauge®USA Section R405.4.1 Compliant Software St. Lucie COUP-f;; I-L FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT • PROJECT - Title7 Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: SMITH ADDITION - - —Bedrooms: 0 User Conditioned Area: 204 WILLIAM SMITH Total Stories: 1 1 Worst Case: No VAN WAL HOMES, INC. Rotate Angle: 0 ST. LUCIE COUNTY Cross Ventilation: ST. LUCIE COUNTY Whole House Fan: Single-family Addition Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: 6105 PINE TREE DRIV County: St. Lucie City, State, Zip: FT. PIERCE, FL, CLIMATE / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 204 1632 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 ADDITION 204 1632 No 1 1 Yes Yes Yes FLOORS # Floor Type Space R-Value Area Tile Wood Carpet 1 Raised Floor ADDITION — — 204 ft' 30 0 0 1 ROOF / V # Type Roof Gable Roof Materials Area Area Color Solar SA Emitt Emitt Deck Pitch Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 221 ft' 0 ft' Medium 0.6 No 0.9 No 0 22.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 204 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) ADDITION 30 Blown 204 ft' 0.11 Wood 2/26/2019 7:56 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS - Adjacent - -- - apace Caviy — t-Width Height Sheathing Framing Solar Belo w —1 N 2 E 3 W Exterior Frame - Wood Exterior Frame -Wood Exterior Frame - Wood ADDITION 13 20 8 160.0 ft' 0 0.25 0.6 ADDITION 13 10 8 80.0 ft' 0 0.25 0.6 ADDITION 13 10 8 80.0 ft' 0 0.26 0.6 0 0 0 WINDOWS Orientation shown is the entered, Proposed orientation. / V # Wall Ornt ID Frame Panes Overhang NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 2 N 1 Metal Low-E Double Yes 0.65 0.25 N 40.0 ft' 2 ft 0 in 1 ft4 in Drapeslblinds W 3 Metal Low-E Double Yes 0.65 0.3 N 12.8 ft' 2 ft 0 in 1 ft 4 in Drapesiblinds None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 190.4 10.45 19.66 .2678 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/Existing/co None COPA 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/Supplemental for None SEER: 14 42 kBtu/hr 1260 cfm 0.85 1 sys#1 SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF ft' DUCTS / V # — Supply— Location R-Value Area — Return — Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT ON RLF HVAC # Heat Cool 1 Attic 6 40 ft' Attic 10 ft' Default Leakage Attic (Default) (Default) 1 1 2/26/2019 7:56 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES - Programabltre�,Thermostatt:: Y- - -- Cffei]]ling Fans: - - - - Coollng Janr[X,] Venting Mar Mar Apr May Jun �X- [ Jul [ ] [X] Aug [X] ] Sep [ ] L 1 r[X,] Nov Dec rt-)C,) Dec [ j Jan [ ]Feb [X] [ ] Jun I Jul [ ]Aug E ]Sep Lxl Octct[X] [ ] Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft' 0 ft 0.3 ADDITION Name: Rating Compant: Date: a-0-Cp- -As 2/26/2019 7:56 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 4 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER -AND -INSULATION -INSPECTION COMPONENT CRITERIA Project Name: SMITH ADDITION Builder Name: VAN WAL HOMES, INC. Street: 6105 PINE TREE DRIVE Permit Office: ST. LUCIE COUNTY City, Stale, Zip: FT. PIERCE, FL, Permit Number. x U Owner: WILLIAM SMITH Jurisdiction: ST. LUCIE COUNTY w x Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ceiling/soffit y the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. In addition, inspection of log walls shall be in accordance with the provisions of [CC-400. 2/26/2019 7:57 AM EnergyGaugeO USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. Addition 12. Duds, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location AttictAttic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 0 13. Cooling system: Capacity 42.0 a) Split system SEER 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 204 d) Room unit/PTAC EER e) Other 14.0 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.262 14. Heating system: Capacity 34.0 c) Area 7c. 52.8 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. b) Wood, raised (R-value) 9b. 30.0 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. 13.0 e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 0 Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans Yes a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit 0 Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not I certify that this home has complied with the Florida Building Code, Energy Conservation, through tl saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, display card will be completed based on installed code compliant features. Builder Signature 115 -W ':�d J--at9- I Address of New Home: 6105 PINE TREE DRIVE City/FL Zip: k MAR S 2019 armittinq Departm, St. Lucie County, F 2/26/2019 7:56:59 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 + wrightsoft• Project Summary o te, Entire House BT. QUICK-CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phore: 772-466-6799 Emit: OUICKCALCS@AOL.COM For. WILLIAM RSMITHADDITION 6105 PINE TREE DR., FT.. PIERCE, FL Notes: Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Insidedb 70 OF Insidedb 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr4b Heating Summary Sensible Cooling Equipment Load Sizing Structure 15357 Btuh Structure 21476 Btuh Duds 6145 Btuh Ducts 8769 Btuh Central vent (0 ctm) 0 Btuh Central vent (0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 21502 Btuh Use manufacturer's data n Rate/swin multiplier 0.95 Infiltration Equipment sensible load 28733 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3095 Btuh Duds 2561 Btuh Central vent (0 cfim) 0 Btuh Area(fl2) Heating Coolingg (none) 1831 1831 Equipment latent load 5655 Btuh Wlume 16479 16479 Airchan�ge�sthour Equiv.AVF 0.38 020 Equipment Total Load ((Sen+Lat) 34388 Btuh (ctm) 104 55 Req. total capacity at 0.70 SHR 3.4 ton Heating Equipment Summary Cooling Equipment Summary Make Make Heil Trade Trade EXISTIG SYSTEM Model Cond R4A448GKA10 AHRI ref Coil ENA4X48L21A1+G9MVE0801716AA1 AHRI ref Efficiency 100 EFF Efficiency 12.0 EER,14 SEER Heating input 6.4 kW Sensible cooling 29400 Btuh Heating output 21953 Btuh Latent cooling 12600 Btuh Temperature rise 50 OF Total cooling 42000 Btuh Actual airflow 400 ctm Actual airflow 1400 cfm Airflowfador 0.019 chit tuh Air flow factor 0.046 dim/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.84 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. _ Ad- wrightsotC 201&Feb-2607.4937 •.•- RigflSUriverm1201919.0.01 RSU09101 Pagel ...CKDoa rls%Wrigtl»ftWACLSMrrH,WILLIAMnp CaIc=M16 FrortOoorfaces NE Wrightsoft' Right-M Worksheet Job: Entire House pate: ar QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL34M Phore: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Roan name Fed vsll Rcan fleigM Roan dimensore Roanarea Errore Home 240.0 ft 9.0 It 1831.0 ft' f-)WASt 144.0 ft 9.0 a heatcnd 41.0 x 31.0 ft 1271.0 ft' Ty CoshxDon number U-wlue (BhHf2-°F) Or HTM (Btuhfi2) Area (f2) or perimeter (fl) Loci (Bluh) Area (M or perimeter (fl) Load (Bfuh) Heat Cod Gros NrPfS Heat Cod Gras NrP)S Heat Cod 6 11 �-D 12C-0 4A5-20b JlD0 12C4)W 4A5-20b 4A54ob 12GOsv , 4A540b 't 4A5-2ob 4A5-20,A 12C-Ow 4A5-2ob 4A5-2ad 0.091 0.560 ne ne _he. s 6e se Sv w sv -sv. nw m+ mw 255 15.68 1.96 33.75 10.34. 549 60 466 0 1192 941 229 918 2025 21721 369 60 288 0 -21 239 0 20 287 0 0 30 239 0 0 - 734 941 -,_.229 609 0 627 732 0 0 1074 609 627 0 563 2025 -217. 468 0 1006 '-562 0 0 ,1881. 468 1350 0 �G �C _0.390 0.091 0.560 0.560 -0.091 0.560 0.560 -0.470 0.091 0.560 0_470 _10.92 255 15.68 15_68 2.55 16.68 15.68 13,16 255 15.68 13.16 1.96 16.16 2.5.15_ " 1.96 25.15 25.15 23.05 1.96 33.75 2829 _21 531 13 40 549 20 20 -82 631 40 54 -21 478 13 20 426 - 10 10 ____30 437 0 0 1218 204 627 1090 307 314 1074 1112 627 716 935 210 1006 837 493 603 `1881 am 1350 1539 279 0 40 9 9 0 0 �82 279 40 0 _ T� C_ F_ F _16s3-mR 19A-30bam -1W30bsp =O.b32 0.034 =MW - _0.90 1.60 wi- 1271 _200 =1414147,1. =1318 1015 _160 _2354 544 _86 911 1_271 = 911 1271 =Cis =1458 544 - = 0.80 =0.80 0.43 =0:43 1271 =20b -�- 0 =0 _1015 0 _ o 6 C) AED a waon 1903 721 Emelope lossIgain 12145 17651 8014 11262 12 a) Infiltration b) Room %entilatim 3212 0 906 0 1927 0 543 0 13 lnbmd gains Osirpanfs@ 230 Applanomk2w 4 920 20001 4 9m 2000 Subk:lal Qirxs6to13) 15357 21476 9941 14725 14 15 Lesademalload Lestansfer Redstibutian Subtlal Dudloads 40°h 41% 0 0 0 15357 6145 0 0 0 21476 8769 40% 41% 0 0 0 9941 3978 0 0 0 14725 6012 Totalroan load Air requiretl(Qm) 21502 400 30245 1400 13919 259 20737 960 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrightsoit- 2019-Feb-2607A937 A&I Rigf-SUte9Uriwema1201919.0.01 RSLI08101 Page l -.CKOOa r&WrigNmftWAC%SMrn4.WILLIAMnp Calc=MIB Frort Doorf w&NE + vdrightsoft' Right-M Worksheet Job: Entire House Date: sy: QUICK CALCS,-INC. 317 ST LUCIE LANE, FORT PIERCE, FL34946 Phone: 772466-6799 Email: QUICKCALCS@AOLCOM 1 2 3 4 5 Roan name Exposed%Wl Ram height Room dimensions Roan area EXIST MASTER 56.0 it 9.0 it heaVmol 20.0 x 18.0 8 360.0 fe NEWWIC 16.0 It 9.0 a heaVond 6.0 x 10.0 it 60.0 it Ty Cordon number U-value (SWh4l2_*q Or HTM (BWh4n Area (1F) a perimeter (ft) Load (BWh) Area (IF) or perimeter (ft) Load (BWh) Heat I Cod Gross N/P/S Heat Cool Gros WP/S Heat Cod 6 11 12C-0sv 4A5-20b 1100 12C-Ow 4AS2ob 4AS20b 12C-DS 4A5-2ob 4AS2ob 4A5-.2M 12C-Ow 4A5-2ob 4AS-2md 168-30ad 19AJ0bsm 19AJObsp 0.091 0.560 ,_0,390 0.091 0.560 0.560 0.091 0.560 0.560 _0.470 0.091 Os60 0.470 ne ne ne- se se se sv sv sv 9N- m nw mx 255 15.68 -11.96 33.76 1C 0 180 0 459 0 352 0 0 0 0 - 0 0 0 0 6 0 0 �G I--G _10.92 255 15.68 15_68 255 15.68 15.68 13.15 255 15.68 13.16 _10.34 1.96 16.16 2515. 1.96 25.15 25.15 _,23.05 1.96 33.75 2829 -0 162 0 0 ______0 162 0 0 -0 413 0 0 317 0 0 -0-0-0 0 0 0 0 0 0 0 0 0 0 0 0 "0 0 0 0 0 0 - 0 0 0 0 0 0 0 54 0 0 0 64 0 0 138 0 0 106 0 0 I� V1/ I�-GG C` F �F_ „0 162 0 54 _____`0 108 0 0 -0 274 0 716 v323 0 211 0 1539 90 0 0 -0-0 90 0 0 229 0 0 -0. 176 0 0 _0032 0.034 _0.034 - =. _0.90 , 0.80 �0.80 1.80 �0.43. -�0.43 _360. =360 0 i0 =576 0 60 0 _60 _60 0 =60 -9 0 ! 96 0 =25 �0 _0 0. 0 =748 6 c)AED e=rson 632 0 Envelope loss/gain 2184 36W 469 403 12 a) Witation b) Room ventilation 749 0 211 0 214 0 60 0 13 Internal gains OOawnls@ 230 Appliarces/dher 0 0 0 0 0 0 Subblal Qines6 to 13) 2933 3838 683 464 14 15 LesseAmalload Lestansw RedisnGNon Subtotal Dudloads 40% 41% 0 0 0 29M 1174 0 0 0 3838 1667 40% 41% 0 0 0 663 273 0 0 0 464 189 Trial room load Airrequired(dm) 4107 76 5405 250 956 18 653 30 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. _ - wrighisoit- 2019-Feb2607:4937 RigFRSdte®thiMM1201919.0.01 RSU08101 .9C P....CKrpoamerls\WdgttsoftWACSMrrH,WILLt4Mnp CaIc=MJ8 FmnDoorfaees NE Paget wrightsoft• Right- J® Worksheet Job: Entire House pale: QUICK CALCS,-INC. By 3175L LUCIE LANE, FORTPIERCE, FL34946 Phone: 772466-6799 Email: OUICKCALCS@AOL.COM 1 2 3 4 5 Rocm name Flposedmdl Rc height Room dimere Roomarea NEWSIITING 24.0 It 9.0 It heaVmd 14.0 x 10.0 It 140.0 ft' Ty Cmstrlxtion number U-value (BWh@i°F) Or HTM (BIJAV) Area (M a pedmehx (ft) Load (BhWh) Area a perimeter Load Heat Cod Gross NOS Heat Cool Grass NIPS Heal Cool 6 Tfc 0 4AS201b ,1100 0.091 0.560 _0.390 ne ne -ne. Z55 15.68 10.92 - 1.96 33.75 `10.34 0 0 —0 0 0 0 0 0 0 0 0 0 11 �1 I--(i �G 12C-0av 4AS20b 4A5-2ob 12C-0sx 4A5-20b 4A5-20b 4A5-2oW 12C-OW 4AS2ob 4A5-2oW 188 30ad. 19A-30bSw JW30tx 0.091 0.560 0.560 0.091 0.560 0.560 —0.470 0.091 0.560 0.470 `0.032 6e M se sv w w _w, M nw w 255 15.68 15.68 265 15.68 15.68 _1316 255 15.68 13.16 1.96 16.16 25.15 90 13 0 77 13 0 196 204 0 151 210 0 �—G 1.98 25.15 25.15 _23.05 1.96 33.75 2829 125 20 20 - 86 10 10 220 307 314 169 493 503 0 I—C 4)/ _0 0 0 0 —0 0 0 0 _0 0 0 0 0 0 0 C_ F .F= =. —0.— 0.80 _0.80 11.60 0_43 =140 0 140 - 40 0 =125 0 112 1224 0 0.034 10.034 - ,d0.43 =140 =60 6 c)AEDaa uson 550 Ern Lope loss/gain 1478 2359 12 a) Infiltration b) Rcom %entilatm 321 0 91 0 13 IMemal gains Oaalpants@ 230 Appliarc s(dher 0 0 0 Subbla Qms6to13) 1799 2449 14 15 Lewwte alload Lesstrarsfer RecrisbibiAw SubN1al Cludloads 40% 41% 0 0 0 17% 720 0 0 0 2449 1000 Total mom load Air required (dm) I 1 2519 47 34W 160 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -FW =191 sort- 2013Feb2607:4937 AC k RighISdte®Udve=1201919.0.01 RSU08101 Page -.CKIDo rtslWdgttsoftWACGMRH,WILLIAMnp Catc=MB FmrtDoorfaees NE Duct System Summary Job: wrightsoft y ry Dale: _ _Entire House B_T. QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Ptcm: 772-466-6799 Emil: QUICKCALCS@AOL.COM For. WILLIAM R SMITH ADDITION 6105 PINE TREE DR., FT. PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest fiction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.080 in/100ft 400 cfnT 103 ft Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.080 iN100ft 1400 cliin Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) HxW (in) Dud Mat! Actual Ln (ft) Ftg.Egv Ln (ft) Trunk EISRMASTER C 2703 38 125 0.080 8.0 Ox0 VIFx 0 0 E)GSITMASTER-A C 2703 38 125 0.080 8.0 Ox0 VIFx 0 0 EXST19 C 3457 43 160 0.080 9.0 Ox0 VIFx 0 0 EXST1e-A C 3456 43 160 0.080 9.0 Ox0 VIFx 0 0 ExsT.tz-6 C 3456 43 160 0.080 9.0 Ox0 VIFx 0 0 EXSTASIC C 3456 43 160 0.080 9.0 Ox0 VIFx 0 0 ExsT.lst-o C 3456 43 160 0.080 9.0 Ox0 VIFx 0 0 EXST.1sFE C 3456 43 160 0.080 9.0 Ox0 VIFx 0 0 NEWSITING C 3450 47 160 0.080 8.0 Ox0 VIFx 11.7 90.0 st1 NEW WIC C 653 18 30 0.080 5.0 Ox0 VIFx 12.9 90.0 st1 Name Trunk Type Htg (Crm) Clg (dm) Design FIR Meloc (fpm) Diam (in) H x W (in) Dud Material Trunk st1 PeakAVF 65 190 0.080 348 10.0 0 x 0 VInIFIX Return Branch Detail Table Name Grille Size (in) Htg (dm) Clg (dm) TEL (ft) Design FR Meloc (fpm) Diam (n) H x W (in) Stud/Joist Opening (in) Dud Mat! Trunk rb1 Ox0 400 1400 0 0 0 0 Ox 0 VIFx Wrightsof l 2019-Feb2607.57:36 + •.•+-..v.�, NgIVSute4DUriv =1201919A.01 RSU06101 Page 1 ACCI\ _CK1DoamertslWngttsoR HVAClSM1rH, WILLIAMnq CaIc=MI6 Fort Door faces NE