HomeMy WebLinkAboutREVISION - BUILDING PERMITOFFICE USE ONLY:
DATE FILED: PERMIT #
REVISION FEW ` RECEIPT #
PLANNING & DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DMSION
2300 VIRGINIA AVENUE
FORT PIERCE FL 34982.5652
(772)462.1553
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
SCANNED
LOCATION/SITEpy
St Lucie County
ADDRESS:
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
trod
0w.ar
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #:
BUSINESS NAME:
QUALIFIERS NAME:
ADDRESS:
CITY: STATE: _
PHONE (DAYTIME):
OWNER/BUILDER INFORMATION:
NAME:
ADDRE S- — p
CITY: ST
PHONE (DAYTIME:
ARCHITECT/ENGINEER INFORMATION:
NAME:
ADDRESS:
CITY:
PHONE (DAYTIME):
SLCCC: 9123109
Revised 06130/17
STATE:
ST. LUCIE CO CERT. #:
FAX:
FAX:
FAX:
ZIP:
ZIP:
ZIP:
illorida Building Code On -
Page 1 of 2
aCIS Home i Wit in i user Repistmnon I Hot Topins I Submit SUMhaMe ; suits a Fads I Pub i.d.mo I coned es I ms sits Map 1,99E, A t$raTl�D
dt','
a V VLICi �tlIYfCO
r rsr Product Approval
s USER: p M=Ds=r St. Lucie County
�==p
Pmdua poorovM Menu > Product or Aoo* ration search > A,rripron List > ApParanon Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
FL2533-R23
Revision
2017
Approved
(J
CertainTeed Corporation -Roofing
20 Moores Road
Malvern, PA 19355
(610) 893-5400 `
mark.d.harner@saint-gobain.com
Mark Hamer
mark.d.harner@saint-gobain.com
ST. LUCIE COUNTY
BUILDING DIVISION
REVIEWED
FOR C CE
REVIEWED BY
DATE
PLANS AND PERM
MUST BE KEPT ON JOB OR
NO INSPECTION WILL BE MADE
Mark D. Hamer
18 Moores Road
MalvernPA 19355
,
(610) 651-584747 ZV18110N
Mark.D.Hamer@sai t 9 i
Roofing
Modified Bitumen Roof System
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC T'i f
Quality Assurance Contract Expiration Date 11/13/2022
Validated By John W. Knezevich, PE
9 Validation Checklist- Hardcopy f}PceHeld..3�.�� �1y� �"�yl �.�•
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
FL2533 R23 COI 2019 01 COI NIEMINEN.odf
Standard
Year
ASTM D6162
2008
ASTM D6163
2008
ASTM D6164
2011
ASTM D6222
2011
ASTM D6509
2009
FM 4470
2012
FM 4474
2011
https://www. floridabuilding. org/prlpr_app_dtl.aspx?param=wGEV XQwtDgvweIwR FXR... 11 /21 /2019
Florida Building Code On',`Page 1 of 1
BOS Home i W,1n i User Ra9ktratlan Hot Topics Submit Surchar0e i Stats&Facts i Publications Contact Us acts Site We i-mis I Search
dRDfICid ;y fy •'r Product Approval
R USER: Public User
PubductApproval Menu > product or Application Search > Application list
Search Criteria
Code Version
2017
Application Type
ALL
Category
ALL
Application Status
ALL
Quality Assurance Entity
ALL
Product Model, Number or Name
ALL
Approved for use in HVHZ
ALL
Impact Resistant
ALL
Other
ALL
Search Results - Aoolications
Refine Search
FL#
2533
Product Manufacturer
ALL
Subcategory
ALL
Compliance Method
ALL
Quality Assurance Entity Contract Expired
ALL
Product Description
ALL
Approved for use outside HVHZ
ALL
Design Pressure
ALL
FL#
Tvoe
Manufacturer
Validated By
to s
FL2533-R23
Revision
CertainTeed Corporation -Roofing
John W. Knezevich, PE
Approved
History
Category: Roofing
(954] 772-6224
Subcategory: Modified Bitumen Roof System
*Approved by Cali Approvals by Cabo shall be reviewed and ratified by Me POC and/or the Commission If necessary.
Coined Us :: 2501 Blair Stone Rued. Tallaha=sec Fl 32399 phone: 850-487-1824
The State of Flonda is an WEED emplayer. Cowtlont 2007-2013 State of Florida.:: privacy Statement :: Accessibility Statement :: Rehmd Statement
Under Florida law, email addresses are public records. If you do not want your a -mall address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395.'pursuant to Section 455.275
(1), Florida Statutes, efledive 0nober 1, 2012, licensees licensed under Chapter 455, F.S. must provide Me Department with an email address a they have one. The
emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please provide Me Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please
dick here.
produce Approval Accepts:
® = 0_; Ed M
Credit Card
Safe
W: ZZI
I;. ��r .,
59
AIMT,
=xey*ll
https://www.floridabuilding.org/t) r_app_lst.aspx 11/21/2019
,Florida Building Code Or''
Page 2 of 2
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
I
Method 1 Option D
06/20/2019
06/20/2019
06/22/2019
08/13/2019
FL #
Model, Number or Name
Description
2533.1
Flintlastic Modified Bitumen
Modified Bitumen Roof Systems
Roof Systems
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL2533 R23 II 2012 06 EINAL Al ER C RTAI TE D MODBIT FL 33
R2
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen, PE PE-59166
Design Pressure: +N/A/-635
Created by Independent Third Party: Yes
Other: 1.) Refer to ER Section 5 for Limits of
Evaluation Reports
Use. 2.) The design pressure noted in this
EL2533 R23 AE 2019 06 FINAL ER CERTAINTEED MODBIT FL2533-
R23.pddf
application relates to one specific system. Refer
to the ER Appendix for all systems and max
Created by Independent Third Party: Yes
design pressures.
Back Next
contact :: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 850-482-1824
The State of Florida a as AA/EEO employer. CowrI 2002-2013 State of Florida :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Honda law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mail to this entity. Instead, contact nee office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant N section 455.275
(1), Honda Statutes, effective October 1, 2012. licensees licensed under chapter 455, F.S. must provide the Deportment wine an email address if May have one. the
emails provided may be used for official communication with the licensee. However email addresses are public mmm. It you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to Me public To determine It you are a licensee under chapter 455, F.S., please
ctick ere-.
Proi Approval Accepts:
W9 ICI gnn
Credit Card
Safe
i� 3iA '' `
p y f 1 � h 4
T
!1
https://www.floridabuilding. org/pr/Pr_app_dtl.aspx?param=wGE V XQwtD gvweIwRFXR... 11 /21 /2019
k �
OONEMO etc.
TABLE
DECK
APPLICATION
TYPE
DESCRIPTION
PAGE
1A
Wood
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
5
�B
Wood
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Banded Insulation, Bonded Roof Cover
6-8
C
Wood
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
9
D
Wood
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
30-11
E
Wood
New, Reroof (Tear -Off) or Recover
D
Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
12-14
-' d
ew, Re .Ter -Oft)
Non-1 a ffied, Mec , Attac ed &TSCS t, Bonded Roo Cover
1
-2
Wood
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
18-19
#G
Wood
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
19
A
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
20-22
B
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
23-27
jC
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
D
Insulated, Mech. Attached Base Sheet, Banded Roof Cover
28-30
i'A
Structural concrete
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
31-38
B
Structural concrete
New or Reroof (Tear -Off)
A-3
Bonded Temp Roof/Vapor Barrier, Bonded Insulation, Bonded Roof Cover
38
C
Structural concrete
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
39
4A
Lightweight concrete
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
40.43
4B
Lightweight concrete
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
44-46
4
Lightweight concrete
New, Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
47-52
4
Lightweight concrete
Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
52
5
Cementitious wood fiber
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
53
5
Cementitious wood fiber
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
54
5
Cementitious wood fiber
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
55
56
Cementitious wood fiber
New, Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
55
6A
Existing gypsum
Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
56-58
6
Existing gypsum
Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
58-59
Ed,
Existing gypsum
Reroof (Tear -Off)
C
Mech. Attached Insulation, Bonded Roof Cover
59
6
Existing gypsum
Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
60
7q
Various
Recover
A-1
Bonded Insulation, Bonded Roof Cover
61-67
7131
Various
Recover
F
Non -Insulated, Bonded Roof Cover
67
NEMO C, LLC
Certific to of Authorization 032455
Prepare by: Robert Nieminen, PE-59166
6`" EDITION (2017) FBC NON-HVH2 EVALUATION
CertainTeed Flintlastic° Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R24 for FL2533-R23
Revision 24: 06/20/2019
Appendix 1, Page 1 of 67
2.
3.
NNEMO etc.
roof system evaluation herein pertains to above -deck roof components. Roof decks shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof
: shall be documented through proper codified and/or FBC Approval documentation.
!ss otherwise noted, fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements:
Wood Deck: OMG #14 Roofgrip with Flat Bottom Plate (Accutrac), ON G HD with OMG 3 In. Galvalume Steel Plate, Dekfast 914 with Hex Plate or 3" Round Insulation Plate, Trufast HD with Trufast 3"
Metal Insulation Plates or FlintFast #14 Fastener with FlintFast 3" Insulation Plates. Minimum 0.75-inch plywood penetration or minimum 1-inch wood plank embedment.
Steel Deck: OMG #12 or H14 Roofgrip with Recessed or Flat Bottom Plate (Accutrac), OMG #12 Standard or HD with OMG 3 in. Galvalume Steel Plate, Dekfast #12 or H14 with Hex Plate or 3" Round
,Insulation Plate, Trufast DP or HD with Trufast 3" Metal Insulation Plates or FlintFast P12 or #14 Fastener with FlintFast 3" Insulation Plates. Minimum 0.75-inch steel penetration and
engage the top flute of the steel deck.
Structural Concrete: OMG #14 Roofgrip with Recessed or Flat Bottom Plate (Accutrac), OMG HD or CD-10 with OMG 3 in. Galvalume Steel Plate, Dekfast H14 or DekSpike with Hex Plate or 3" Round Insulation
'Plate, Trufast HD or CF with Trufast 3" Metal Insulation Plates or FlintFast #14 Fastener with FlintFast 3" Insulation Plates. Minimum 1-inch embedment. Fasteners Installed with a pilot
-hole in accordance with the fastener manufacturer's published installation instructions.
!ss otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, GlasRac Roof Board or gypsum -based roof board that meets the OA requirements
A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover.
4. lVinimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for, or installed beneath rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover),
hereby the base sheet screws and plates are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck
listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper
codified and/or FBC Approval documentation.
S. Freliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016).
6. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturers published instructions
D
Hot asphalt.(HA):
Full coverage at 25-30lbs/square
➢
Ashland Pliodeck(A-PD):
Continuous 0.75 inch wide ribbons, 12-inch o.c. Ribbons of subsequent layers shall be perpendicular to those in the layer below.
D
Dow INSTA-STIK Quik Set Insulation Adhesive (D-IS):
Continuous 0.75 to 1 Inch wide ribbons, 12-inch o.c.
D
ICP Adhesives Polyset BOARD -MAX:
Continuous 3-inch ribbons,12-Inch o.c.
D
ICP Adhesives Polyset CR-20:
Continuous 2.5 to 3-Inch wide ribbons, 12-inch o.c.
➢
Millennium One Step Foamable Adhesive(M-OSFA):
Continuous 0.25 to 0.5-inch wide ribbons, 12-Inch o.c.
➢
Millennium PG-1 Pump Grade Adhesive (M-PG3):
Continuous 0.5 to 0.75-Inch wide ribbons, 12-inch o.c.
D
OMG OlyBond 500 or OlyBond Green (OB500):
Continuous 0.75-inch wide ribbons,12-inch o.c. (PaceCart or SpotShot)
D
Note: When multiple loyers(s) of insulation and/orcoverboard areInstalled in ribbon-opplled adhesive, boards shall be staggeredfrom layer-to-loyer.
D
Note: The maximum edge distance from the adhesive ribbon to the edge of the Insulation board shall be not less than one-half the spedJled ribbons spacing.
7.
nless
otherwise noted, all insulations are flat -stock or taper board of the minimum thickness noted. Tapered polylsocyanurate at the following thickness limitations may be substituted with the following Maximum
(
esign
Pressure (MDP) limitations. In no case shall these values
be used to 'increase' the MOP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the
' thinner
board listed below maybe used as a drop -in for the equivalent thicker material listed in the table:
➢
Ashland Pliodeck (A-PD) @ 12-Inch o.c.
MDP -105.0 psf (Min. 1.0-Inch)
➢
Ashland Pliodeck (A -PO) @ 6-Inch o.c.
MDP -277.5 psf (Min. 1.0-inch)
D
Dow INSTA-STIK Quik Set Insulation Adhesive (D-IS):
MDP -120.0 psf (Min. 1.0-Inch)
D
ICP Adhesives Polyset CR-20:
MDP -117.5 psf (Min. 1.0-Inch)
➢
Millennium One Step Foamable Adhesive(M-OSFA):
MDP -157.5 psf (Min. 1.0-Inch)
➢
Millennium PG-1 Pump Grade Adhesive(M-PGS):
MDP -157.5 psf (Min. 1.0-Inch)
D
OMG OlyBond 500 (013500):
MDP -45.0 psf (Min. 0.5-Inch Multi -Max FA3)
D
OMG OlyBond 500 (OB500):
MDP -187.5 psf (Min. 0.5-inch ISO 95+GL)
D
OMG OlyBond 500 (OB500):
MDP -315.0 psf (Min. 0.5-Inch ENRGY 3)
D
OMG OlyBond 500 (08500):
MDP -487.5 psf (Min. 0.5-inch ACFoam II)
NEMO
C, LLC
i
Evaluation Report 3520.03.04-R24 for FLZ533-RZ3
Certificate
of Authorization #32455
6r"EDITION (2017) FBC NON-HVHZ EVALUATION Revision 24: 06/20/2019
Prepared
by: Robert Nieminen, PE-59166
CertainTeed Flintlastic• Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 2 of 67
*NEMOrI � etc.
8. Bonded polyisocyanuratelnsulation boards shall be ma
9. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC
Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD3, FM Loss Prevention
Data Sheet 1-29 and Roofing Application Standard RA5 117. Assemblies marked with an asterisk` carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3
enhancements.
10. For assemblies with all components fully bonded In place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no
rational analysis is permitted.
11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum
requirements for the system. 'Testing and analysis shall be in accordance with AN51/SPRI FX-1 or Testing Application Standard TAS 105.
12. or existing substrates in a bonded recover or re -roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing
oaf system (for recover) shall be capable of resisting project design pressures on Its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with
NSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124.
13. or Concrete Deck or Recover Applications using System Type D, the insulation is optional.
14. ightweight Insulating Concrete (LWC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWC
Product Approval for specific deck construction and limitations. For systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat thickness Is 2-Inches.
Ior LWC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. For "pre-existent" LWC references, listings were established through testing over lightweight concrete cast using only foaming
gent (ASTM C896), water and Portland cement (ASTM C150), with no proprietary additives, in accordance with procedures adopted by Miami -Dade BCCO (FBC CER1592). Unless otherwise noted, use of these listings
I new construction or re -roof (tear -off) applications is at the discretion of the Designer of Record and Authority Having Jurisdiction.
15. L+nless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications.
lf a
REFERENCE
LAYER
MATERIAL
APPLICATION
BP -AA
(Base and Pry sheets, Asphalt -Applied)
Base
Glasbase; All Weather/Empire Base; Flexiglas Base; Flintlastic Base 20
Hot asphalt at 20-40 lbs/square
Ply
One or more Flintglas Ply 4; Flintglas Premium Ply 6
BP-AA2
(Base, Sppt-Asphalt-Applied)
Base
Yosemite Venting Base
Hot asphalt in 24-inch diameter spots in
30-Inch grid pattern
BP-AA3
(Base, Spot -Asphalt Applied)
Base
Yosemite Venting Base
Hot asphalt in 9-Inch diameter spots in grid
pattern noted herein.
BP-AA4
lease. Strip -Asphalt -Applied)
Base
Yosemite Venting Base
Hot asphalt in 9-Inch wide ribbons spaced
as noted herein.
BP-CA2
Base/Ply
Glasbase; All Weather/Empire Base; Flexiglas Base; Flintlastic Base 20
Henry #903 Adhesive at 1.5 gal/square
BP-CA3
Base/Ply
Glasbase; All Weather/Empire Base; Flexiglas Base; Flintlastic Base 20
Millennium Hurricane Force Membrane
Adhesive, beads spaced 6-Inch o.c.
SBS-AA
ISBS, Asphalt -Applied)
Base
Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
asphalt at 20-401bs/square
Ply
One or more Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
Cap
Flintlastic FR Cap 30; Flintlastic FitHot
Cap 30 CoolStar; Flintlastic FR Dual Cap; Flintlastic FR-P; Flintlastic FR-P
CoolStar; Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar, Flintlastic GMS; Flintlastic GMS CoolStar
NEMO SIC, LLC
Certificate of Authorization #32455
Prepare I
by: Robert Bl eminen, PE-59166
6'" EDITION (2017) FBC NON-HVHZ EVALUATION
CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R24 for FL2533.R23
Revision 24: 06/20/2019
Appendix 1, Page 3 of 67
16. V
i
�5
� tir
v
v,
Y
®MEMO I etc.
REFERENCE
LAYER
MATERIAL
APPLICATION
Base
Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
Note:
Base ply cures overnight prior to application of the ply or cap ply.
SBS-CAI
(SBS,Ctxd-Applied)
ply
Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
Cold
Emcee nd Brush or Karnak No. 81Adhesive
Process Modified Bitumen Adhesive Brush
Grade at 1 gal/square
Cap
Flintlastic FR Cap 30; Flintlastic FR Cap 30 CoolStar; Flintlastic FR Dual Cap; Flintlastic FR-P; Flintlastic FR-P
CoolStar; Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar, Flintlastic GMS; Flintlastic GMS
CoolStar
Base
Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
SBS-CA2
Pas. Cold Applied)
Ply
Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
Henry #903 Adhesive at 1.5 gal/square.
Cap
Flintlastic FR Cap 30; Flintlastic FR Cap 30 CoolStar; Flintlastic FR Dual Cap; Flintlastic FR-P; Flintlastic FR-P
CoolStar; Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar, Flintlastic GMS; Flintlastic GMS CoolStar
Base
Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
SBS-CA3
Ply
Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
Millennium Hurricane Force Membrane
(SBS, Cold Applied)
Adhesive, beads spaced 6-Inch o.c.
Cap
Flintlastic FR Cap 30; Flintlastic FR Cap 30 CoolStar; Flintlastic FR Dual Cap; Flintlastic FR-P; Flintlastic FR-P
CoolStar, Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar, Flintlastic GMS; Flintlastic GMS Coo(Star
Base
Flintlastic Ultra Poly SMS Base; Flintlastic Base 20 T
SBS-TA
(SBS,Torch-Applied)
Torch -Applied
Ply
One or more Flintlastic Ultra Poly SMS Base; Flintlastic Base 20 T
Cap
Flintlastic FR Cap 30 T; Flintlastic FR Cap 30 T CoolStar; Flintlastic GTS-FR; Flintlastic GTS-FR CoolStar
Base
One or more Flintlastic APP Base T; Flintlastic STA; Flintlastic STA Plus
APP-TA
(App, Torch -Applied)
Torch -Applied
Cap
Flintlastic STA; Flintlastic STA Plus; Flintlastic GTA; Flintlastic GTA CoolStar; Flintlastic GTA-FR; Flintlastic GTA-FR
CoolStar
SBS-SA-H
(505, Se16Adhedng, Hybrid Systems)
Base/Ply
Black Diamond Base Sheet; Flintlastic Ultra Glass SA
Self -Adhering
SBS-SA
Isar Self-Adhedng)
Base
Flintlastic SA PlyBase; Flintlastic SA Mid Ply
Self -Adhering
Ply
Flintlastic SA PlyBase; Flintlastic SA Mid Ply
Cap
Flintlastic SA Cap; Flintlastic SA Cap FR CoolStar, Flintlastic SA Cap FR; Flintlastic SA Cap FR CoolStar
por barrier options for use over structural concrete deck followed by adhered insulation carry the following MDP limitations. The lesser of the MOP listings below vs. those in Table 3A applies:
e. rADHERED g. •
OPTION PRIMER,
It
VAPOR BARRIER
INSULATION ADHESIVE
MDP (PSF)
TYPE
ATTACH
VB-1.
FIIntPrime
Flintlastic SA PlyBase
Self -adhering
OB500, 12-inch o.c.
-82.5
VB-2.
FIintPrime
Flintlastic GTA
Torch -applied
M-OSFA or M-PG3, 12-inch o.c.
-420.0
VB-3.
FIIntPrime
Flintlastic Base 20 T, Flintlastic FR Cap 30 T or Flintlastic GTS
I Torch -applied
M-OSFA or M-PG3, 12-Inch o.c.
-495.0
17. " DP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads.
NEMO ETC, LLC Evaluation Report 3520.03.04-R24 for F1.2533-1323
Certificate of Authorization 032455 6r" EDITION (2017) FBC NON-HVH2 EVALUATION Revision 24: 06/20/2019
Prepare I
by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 4 of 67
11
0
®
*NEMO
etc.
WOOD .REROOF
(TEAR -OFF)
SYSTEM TYPE NON -INSULATED,
MECHANICALLY ATTACHED
BASE SHEET, BONDED ROOF COVER
5Ystem
Oeck (.
- '�,0ase Sheet
. Roof Cover (Note 15) MDP
o•
,(Note 11
Base
- 174t¢ ers
Attach
Ply
Cap
(Psf) '
W.
8
/32-Inch plywood at
Glasbase; Flexiglas; Flintlastic
Base 20; All Weather/ Empire
t'�b
32 ga.,1-5/8-igch dia. tin caps
..
8-inch o.c. at 4-Inch lap and 8-inch o.c. in three
BP -AA, SBS-AA,
SBS-AA, 585-TA
4-inch spans
Base; Poly SMS Base; Ultra Poly
with 11 ga: annular ring shank
r -a.
(3), equally spaced, staggered center rows
SBS-TA or APP-
or APP-TA
-60.0
SMS Base; Yosemite Venting Base
nails
S1
TA
Glasbase; Flexiglas; Flintlastic
Cap riails�i'inch diameter,
9
Min. 15/32-inch plywood at
Base 20; All Weather/ Empire
0.032-inch thick metal cap with
6-Inch o.c. at 4-Inch lap and 6-inch o.c. at five
onal) BP-
(Optional)
or SBS-
max 24-Inch spans
Base; Poly SMS Base; Ultra Poly
0.120-Inch shank diameter,
(5) equally spaced, staggered center rows
,(OSBS-AA
AA, SBS-AA or
TA
-67.5
SMS Base; Yosemite Venting Base
annular ring shank nails.
Glasbase; Flexiglas; Flintlastic
Se c
1119 ca s
BP -AA, SBS-AA,
VIRMQW-1
a_
nails a a
_ u
s[a ere c nt row
SMS Base; Yosemite Venting Base
Glasbase; Flexiglas; Flintlastic
8I
Min. inch exterior grade
Base 20; All Weather/ Empire
Simplex MA%%Cap
6-Incho.c.s lap and 6-inch o.c. in two
(Optional) BP -
SBS-AA, SBS-TA
od at
plywood
plywood at max. 24-inch spans
Base; Poly SMS Base; Yosemite
aced,
(2) equally spaced, staggered center rows
AA, SBS-AA, SBS-
or APP-TA
-90.0
Venting Base
7A °r APP-TA
W 8
Min. 15/32-inch exterior grade
Flintlastic APP Base T
Simplex MAXX Ca
p p
6-inch o.c. at 2-inch lap and 6-inch o.c. in two
(Optional) APP-
APP-TA
plywood at max. 24-inch spans
(2), equally spaced, staggered center rows
TA
-90.0
W-g
Min. 19/32-inch plywood at
Glasbase; Flexiglas; Flintlastic
Base 20; All Weather/Empire
32 ga., tin caps
s
1-5/8-Inch dla. p,
4-inch o.c. at 3-Inch lap and 4-Inch o.c. in four
BP -AA SBS-AA,
SBS-AA, SBS-TA
max 24-inch spans
Base; Poly SMS Base; Ultra Poly
with 11 ga. annular ring shank nails
(4), equally spaced, staggered center rows
-TA or APP-
or APP-TA
-105.0
SMS Base; Yosemite Venting Base
TABS
Glasbase; Flexiglas; Flintlastic
W-8
Min. I5/32-Inch exterior grade
Base 20; All Weather/ Empire
Sim
Simplex MAXX Cap
6-inch o.c. at 2-Inch lap and 6-inch o.c. in three
(Optional) BP -
AA, SBS-AA, SBS-
SBS-AA, SBS-TA
plywood at max. 24-Inch spans
Base; Poly SMS Base; Yosemite
(3), equally Spaced, staggered center rows
or APP-TA
-105.0
I
Venting Base
TA °r APP-TA
w 85I
Min. 15/32-inch exterior grade
24-Inch
Flintlastic APP Base T
Simplex MA%X Ca
p p
6-Inch o.c. at 2-inch lap and 6-inch o.c. in three
(Optional) APP-
APP-TA
-105.0
plywood at max. spans
(3), equally spaced, staggered center rows
TA
NEMO
ETC, LLC
Evaluation Report 3520.03.04-R24 for FLZ533-RZ3
Zertifica
a of Authorization d32455
6 "EDITION (2017) F8C NON-HVHZ EVALUATION
Revision 24: 06/20/2019
'repave
by: Robert Nieminen, PE-59166
Certaln7eed Flintlastic* Modified Bitumen Roof Systems; (610) 651-SO47
Appendix 1, Page 17 of 67
r.
ONEMO I etc.
TA . .. ... E
SiSTEMTYPEE: KON-INSULATED; MECHA�ICAULY ATTACHED BASE SHEET, BONDED ROOF COVER
sytem
Dec
Base Sheet'
Roof Cover (Note 15)
MDP
o.
(Na
Base Fasteners,;`,` Attach
Ply Cap
(PSf)
SE-AOHERINGSYSTEMS:
.-tz>
8-Inch o.c. at min. 3-inch lap and 8-inch o.c. in
W. 6
Min. 1 lywood
Flintlastic SANailBase
Note �J
two (2), equally spaced, staggered center rows.
(Optional)
SBS-SA
-82.5'
at max 2 - spans
-:J
Stress plates shall be primed with FlintPrime
SBS-SA
(ASTM D41) primer or FlintPrime SA
Flintfast 3 in. Insulation Plates with
6-inch o.c. at min. 2-Inch lap and 6-Inch o.c. in
W 7
Min. 15/32-inch plywood
Flintlastic SA NailBase
FlintFast #12 or #14; Trufast 3" Metal
three (3), equally spaced, staggered center rows.
(Optional)
SBS-SA
-97.5'
at max 24-inch spans
Insulation Plates with DP or 1-10; OMG 3
Stress plates shall be primed with FlintPrime
SBS-SA
In. Round Metal Plates with OMG #14 HD
(ASTM D43) primer or FlintPrime SA.
_
Flintfast 3 in. Insulation Plates with
6-Inch o.c. at min. 2-Inch lap and 6-Inch o.c. in
W-7Min.
W 8
15/32-inch plywood
'I
Flintlastic SANailBase
FlintFast #12 or #14; Trufast 3" Metal
four (4), equally spaced, staggered center rows.
(Optional)
5B5-SA
-127.5'
at max 24-Inch spans
Insulation Plates with DP or HD; OMG 3
Stress plates shall be primed with FlintPrime
SBS-SA
In. Round Metal Plates with OMG #14 HD
(ASTM D41) primer or FlintPrime SA.
HYB Ia
SYSTEMS:
Glasbase; Fleziglas; Flintlastic
Flintfast 3 in. Insulation Plates with
6-inch o.c. at 4-inch lap and 6-inch o.c. In three
W-SI
Min. 15/32-inch plywood
Base 20; Poly SMS Base; Ultra
FlintFast N12 or lt14; Trufast 3" Metal
(3), equally spaced, staggered center rows.
SBS-SA-H
SBS-AA, SBS-
-97.5
at max 24-inch spans
poly SMS Base
Insulation Plates with DP or HD; OMG 3
Stress plates shall be primed with FlintPrime
TA or APP-TA
in. Round Metal Plates with OMG #14 HD
(ASTM D41) primer or FlintPrime SA.
W 90
Min. 19/32-Inch I
plywood
Glasbase; Fleziglas; Flintlastic
Base 20; Poly SMS Base; Ultra
Note 2
7-inch o.c. at 3-inch lap and 7-Inch o.c. in three
5B5-SA-H
SBS-AA, SBS-
-105.0
a[ max 24-inch spans
Poly SMS Base
(3), equally spaced, staggered center rows
TA or APP-TA
Glasbase; Fleziglas; Flintlastic
Flintfast 3 in. Insulation Plates with
6-inch O.C. at 4-Inch lap and 6-Inch o.c. in four
W 9
Min. 15/32-inch plywood
Base 20, Poly SMS Base; Ultra
FlintFast #12 or #14; Trufast 3" Metal
(4), equally spaced, staggered center rows.
SB5-SA-H
5B5-AA, SBS-
-127.5
at max 24-inch spans
Poly SMS Base
Insulation Plates with DP or HD; OMG 3
Stress plates shall be primed with FlintPrime
TA or APP-TA
I
in. Round Metal Plates with OMG 414 HD
(ASTM D41) primer or FlintPrime SA.
CONY
NTIONAL SYSTEMS: -
Min.23/32-inch exterior
Glasbase; All Weather/Empire
BP-AA,SBS-
W-9
grade plywood at max.
Base; Fleziglas Base; Flintlastic
Note 2
12-Inch at 4-Inch lap and 36-inch in two
AA, SBS-TA or
SB A, SBS-
-30.0'
24-inch spans
Base 20; Yosemite Venting Base
ally roo.ws
(2), equally spaced, staggered center rows
APP TA
or
TA or APP-TA
Min. 23/32-inch exterior
Glasbase; All Weather/Empire
BP-AA,SBS-
W-93
grade plywood at max.
Base; Flexiglas Base; Flintlastic
Note 2
12-inch o.c. at 4-Inch lap and 24-inch o.c. in two
SBS-TA or
SBS-AA, SBS-
-q5.0'
24-inch spans
Base 20; Yosemite Venting Base
(2), equally spaced, staggered center rows
APP-TA
TA or APP-TA
W-94
Min. 23/32-Inch exterior
grade plywood at max.
Poly SMS Base; Ultra Poly SMS
Note 2
12-Inch o.c. at 4-inch lap and 36-inch o.c. in two
BP -AA, SBS-
AA, 5B5-TA or
SBS-AA, SBS-
-45.0'
24-inch spans
Base
(2), equally spaced, staggered center rows
APP-TA
TA ar APP-TA
NEMO C, LLC
Certifica a of Authorization #32455
Prepared by: Robert Nieminen, PE-59166
6'"EDITION (2017) FBC NON-HVH2 EVALUATION
CertainTeed Flintlastic• Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R24 for FL2533-R23
Revision 24: O6/20/2019
Appendix 1, Page 18 of 67
�r u
G1
NEMOetc.
WOOD DEC
SYSTEM TYPE E; NON -INSULATED, MECHANICALLY ATTACHED Bes, —HFFT, BONDED ROOF COVER
Sy
tem Deck �,'-a�' Base Sheet Roof Cover (Note 15) MDP
o•
' (Note l)
Base Sv
.Fasteners
- Attach
Ply
Cap
IPA
Glasbase; Flexigla�F(intlastic
Flintfast 3In. Insulation Plates with
(Optional) BP-
W.
95
Min. 15/32-Inch plywood
Base 20; Poly SMS Base; Ultra
FIIntFast #12 or #14; Trufast 3" Metal
6-' h o.c. at 4-inch lap and 6-Inch o.c. in three
AA, SBS-AA,
SBS-AA, SBS-
at max 24-inch spans
Poly SMS Base; Yosemite Venting
Insulation Plates with DP or HD; OM
, equally spaced, staggered center rows
SBS-TA or
TA or APP-TA
g7 5
Base
in. Round Metal Plates with OMG _
APP-TA
W
6
Min. 15/32-Inch plywood
Flintlastic APP Base T
OMG 3In. Round Metal Plates wit G
6-Inch o.c. at 4-inch lap and 6-Inch o.c. in three
at max 24-Inch spans
#14 HD
(3), equally spaced, staggered center rows.
APP-TA
APP-TA
-97.5
Glasbase; Flexiglas; Flintlastic
Base 2 All Weather/ Empire
Flintfast 3 in. Insulation Plates with
8-inch o.c. at 4-inch lap and 8-inch o.c. at three
(Optional) BP -
SBS-AA or
W
7
at max 24-Inch s ans
at x 24-i ch spans
p
o
Base; Poly SMS Base; Ultra Poly
y Y
Trufast 3° Metal Insulation
wth
(3) equally spaced, staggered center rows
AA, SBS-AA or
585-TA
-97.5
SMS Base; Yosemite Venting Base
Plates T
Plates with Trufast HD
SBS TA
Glasbase; Flexiglas; Flintlastic
W
8
Min. 19/32-inch plywood
Base 20; Poly SMS Base; Ultra
7-inch o.c. at 3-inch lap and 7-inch o.c. in three
BP-AA,SBS-
5B5-AA, SBS-
at max 24-inch spans
P
Poly SMS Base; Yosemite Venting
Y g
Note 2
(3), equally spaced, staggered center rows
AA, SBS-TA or
TA or APP-TA
-105.0
Base
APP TA
W
9
/32-inch
Min. 19/32-Inch plywood
Flintlastic APP Base T
OMG 3 in. Round Metal Plates with OMG
#14 HD or Dekfast Hex Plate with Dekfast
7-Inch o.c. at 3-inch lap and 7-Inch o.c. in three
APP-TA
APP-TA
at max spans
P
#14
(3), equally spaced, staggered center rows
-SO5.0
Glasbase; Flexiglas; Flintlastic
Flintfast 3 in. Insulation Plates with
(Optional) BP-
W-1
0
Min. 15/32-Inch plywood
Base 20; Poly SMS Base; Ultra
FlintFast H12 or 414; Trufast 3' Metal
6-inch o.c. at 4-Inch lap and 6-Inch o.c. in four
AA, SBS-AA,
SBS-AA, SBS-
at max 24-Inch spans
Poly SMS Base; Yosemite Venting
Insulation Plates with DP or HD; OMG 3
(4), equally spaced, staggered center rows
SBS-TA or
TA or APP-TA
-127.5
Base
in. Round Metal Plates with OMG #14 HD
APP-TA
W-1
1
Min. 35/32-Inch plywood
Flintlastic APP Base T
OMG 3 in. Round Metal Plates with OMG
6-Inch o.c. at 4-Inch lap and 6-Inch o.c. in four
at max 24-Inch span,
#14 HD
(4), equally spaced, staggered center rows.
APP-TA
APP-TA
-127.5
_.CO
-APPLIED SYSTEM,:
Glasbase; Flexiglas Base;
W-1Q2
Min. 15/32-inch wood
plywood
Flintlastic Base 20; All Weather/
Empire Base; Yosemite Venting
Flintfast 3In. Insulation Plateswith
FIIntFast #12 or #14; Trufast 3" Metal
8-inch o.c. at 4-Inch lap and 8-Inch o.c. in three
(Optional)
)
at max 24-Inch spans
Base; Flintlastic Poly SMS Base;
Insulation Plates with DP or HD
(3), equally spaced, staggered center rows
SBS-CAI
SBS-CAI
-52.5
Flintlastic Ultra Poly SMS Base
SYSTEM TYPE F:
s BONDED ROOF COVER
Sy
tem` �'I' Deck - -
Primer -
Roof Cover(Note 15) -
o. _ ,i. " (Note 1)
'Base
PIY
MOP (psf)
Cap _
W-1
3 Min. 15/32-Inch plywood at max 24-Inch spans
FlintPrime or FIIntPrime SA
SBS-SA-H
(Optional) SBS-TA, APP-TA
SBS-TA, APP-TA -112.5
W-1
4 Min. 15/32-Inch plywood at max 24-Inch spans
FlintPrime or FlintPrime SA
SBS-SA
(Optional) SBS-SA
SBS-SA -127.5
LLC
by: Robert Nleminen, PE-59166
6TM EDITION (2017) FBC NON-HVHZ EVALUATION
CertainTeed Flintlastic• Modified Bitumen Roof Systems; (610) 6SI-5847
Evaluation Report 3520.03.04-R24 for FL2533.RZ3
Revision 24: 06/20/2019
Appendix 1, Page 19 of 67
w