HomeMy WebLinkAboutPRODUCT REPORT0
Compliant with Florida Building Code 2017 (61h ed.)
Compliant with Florida Product Approval Rule # 611320-3
Compliant: Keystone Certifications
2160 SW Porria Drive
Palm City, Fl. 34990
SQANNEQ
St Luce County
Product: 1" Nailstrip 26GA Steel Roof Panel FBC Sec. 1507.4.2
Yield strength: 50 ksi min.; Attached to min.15/32" plywood or
Wood Deck w/ 0.42 specific gravity with 16" Coverage (Max.)
Rib Height 1"
Corrosion Resistant Compliant: FBC Sec. 1507.4.3
Fastener 1: #10 x 1" (min.) Pancake Head Wood Screw to penetrate 3/16" (min.) thru
bottom of support.
Adhesive/Sealant : Bostik 915' Chem -Chalk one component, polyurethane adhesive with
3/16" continuous bead application along base of male rib vertical flange at each panel
seam.
Underlayment: To be compliant with FBC Sec 1507.1.1
Slope: Shall be in compliance with FBC Sec. 1507.
Install Details:. Table A Allowable Loads
METHOD i
METHOD 2
DESIGN PRESSURE*
_
:-85 PSF Mainfield
-97.25 PSF Perimeter
FASTENER SPACING _
6" O.C.
6" O.C.
SEAM ADHESIVE
Not required
3/16" continuous bead
(see details
Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527
UL 580-06 & UL 1897-04 TEST REPORT D8133.01-450-18 06/30/15 Specimen #1 & #2
EQUIVALENCY: UL1897-04 is equivalent to Test Standard ULI897-12. *Design -Pressure margin of safety_2;1_
Certificate of Independence:
Locke Bowden, P.E. does not have, not will acquire a financial �gNftAn ggycompany manufacturing or distributing products
under this evaluation. ��``%L g�v(i• ��i,
Locke Bowden, P.E. is not owned, operated, or controlle rIMp? f, 0arip1paurer, or distributing products under this
report. V Y . • '• ,..
• '• ' seal
o
•• STATE OF ; •C� i
Limitations:
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 61, ad..
2. Minimum slope to be compliant with Florida Building Code 2017 611 ed., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D
4. Engineering analysis for "project specific approval by local authorities wlurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6t' ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 far Structural
Loading.
7. This report does not imply warranty; installation, recommended product use outside of this report
FL 17022.5 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel - Details
16"
Panel Profile
16" o.c.
—I-
3/4"
J
Deck:
-15/32" or greater Plywood, or
- Wood plank
Integral Snap Lock
For METHOD 2:
Apply 3116" Bead Bostik 915T1d Sealant
Continuous Along Male Rib Vertical Flange
Fastener
#10 x 1" Min. per Table "A"
Pancake Head Wood Screw
(Typical Fastening Pattern Across Width)
1"
FL-17022.5 1.0 Nail -Strip (26GA Steel),-16"Wide Roof Panel --Details
15/k" or greater Plywood, or
- Wood plank
Fngtpnzr
Isometric View
Apply 3/16" Bead Bostik 915TM Sealant
Continuous Along Male Rib Vertical Flange