Loading...
HomeMy WebLinkAboutBUILDING SITE PLANSA E I I I I I I I I I I I I I I I I I I I I I I I I a, ti4 I I ' I I I I I I I ' h I i I I > I a I I N � I I ' I I ' I I I I > I I I I I c I I I CLEAN 1 I I UT — � I 3Y4" I i i (NAT�R METER I I I I I I I I CONST. 60 LF OF 18" RCP/W MITERED ENDS PER I DOT 272 I I I I I I I 35 1 i 1 I I I I I I I I I I � R/W LINE I I I Q 21 75.00' 22 550.00' 94.50" `L EXISTING TREES TO REMAIN (TYPICAL) ,A+ .y EXISTING TREES TO REMAIN (TYPICAL) 44" SANITAVSEWE N 89'36'20" E 75.35' 14,00'I 1 11\ 21.30 � I � N I 21.00 \ L ovrllr7y EXISTING ELEVATION (TYPICAL) a WAREHOUSE ` 0 0 PO.� F.F.EL. 22.50 0 D EXISTNG FURROW (TYPICAL) N 94.50' LEVEL GRADE Q C7 C7 C7 v 50.00' 22 $ OFFICE 8 00 �1 o- N F.F.EL. 22.50 N ti+ 9► P 50.00' 12' INV. 19.70 f I EXISTING DITCH TC BE FILLED 3 I 00 I � N I O I .4 (\ Z I I X I EXISTING CABBAGE PALMS TO REMAIN i �+ I 1 o' I V RETENTION AREA I Cl+ R/W LINE 1. 1" TYPE S-3 ASPHALTIC CONCRETE 2. 6" LIMEROCK OR CEMENTED COQUINA SHELLROCK, PRIMED 3. 8" STABILIZED SUBGRADE, (75 PSI FBV) s COMPACTED TO 98% OF MAXIMUM DENSITY AS PER AASHTO T-180 TYPICAL PAVEMENT SECTION �5 1.00 C7 C7 C7 0 I o- o TREES IN THIS AREA NOT SHOWN FOR CLARITY N 1 \ NC4 14 O 00 , acres 174t N m 174452 sq. ft. A LIMITS OF CLEARING moo+ - 18 5 OUTFALL (EXISTING GROVE DITCH 17.0 3ns 6' VIBURNUM HEDGE (TYPICAL) OAK TREE (TYPICAL) 551.49' S 89'49'03" W PAVING AND DRAINAGE NOTES 1. The Contractor and/or construction surveyor shall verify the elevation of the benchmark shown on construction plans. Verify all elevations of existing pavement, stubouts, and structures before starting construction and notify the Engineer if any discrepancy in elevations exist. 2. All construction to be in accordance with the Florida Department of Transportation and/or St. Lucie County requirements and specifications, as applicable. 3. Roadwork within the Rock Road right-of-way is subject to permitting and approval by the governmental authority having jurisdiction. 4. Disturbed areas shall be restored to their original condition. All unpaved and unsodded areas disturbed during the construction shall be seeded and mulched in accordance with Section 570 of the Florida Department of Transportation Specifications. Sod shall meet the requirements of Section 578 and Section 981 of the Florida Department of Transportation Specifications. 5. Materials for roadway paving & drainage construction shall meet applicable requirements for roadway construction as outlined in the Florida Department of Transportation (FDOT) Standard Specifications, latest edition. 6. On -site striping shall be 4" white traffic paint (Type T-1) in accordance with the Florida Department of Transportation Standard Specifications for Reflective Traffic Paint (Section 971-12). C, CULPEPPER & TERPENING,iNc. CONSULTING ENGINEERS & LAND SURVEYORS 805 VIRGINIA AV., SUITE 15 FORT PIERCE, FLORIDA 34982 (407) 464-3537 30 1369.00' •m 6.00 acres t 261,150 sq. ft. n 816.82' 1368.32' 7. Signing shall be "engineer grade", in accordance with the Florida Department of Transportation Standard Specifications, Manual on Uniform Traffic Control Devices and St. Lucie County requirements. Stop signs shall be 3011 x 30". 8. Concrete for structures, curbs, wheel stops, parking, loading areas, and sidewalks shall have minimum 28 day compressive strength of 3000 psi. 9. All areas of fill, limerock, stabilization, subgrade, etc., shall be compacted to a minimum of 98% of maximum density, in accordance with AASHTO T-180. 10. The Engineer and St. Lucie County shall be notified for inspection of subgrade, base and asphalt, at least 24 hours in advance of subsequent construction. 11. Concrete pipe shall meet the requirements of the Florida Department of Transportation Standard Specifications for Road and Bridge Construction, latest edition, Section 430 and Section 941. 12. Upright handicapped signs to be provided at all handicapped parking spaces, in accordance with the Manual on Uniform Traffic Control Devices and St. Lucie County requirements. 13. The Florida Department of Transportation approved local cemented coquina shellrock is an approved alternative to limerock. BY DATE DESIGNED ylm/ 1-264'S. CALCS ((/ DRAWN _._.f✓' fit _..i-Z(,-93 DETAILED CHECKED APPROVED GRAPHIC SCALE l( 60 ( IN FEET ) 1 inch = 30 ft. 0 0 N IN O 0 0 O 120 SC N/vEo St. Lucie count., AMERICAN CONCRETE INDUSTRIES, INC. FORT PIERCE YARD SITE PAN 011 D TE: 11 20 92 H IZ. CALE: "=30' VER . SCALE: NONE JOB No. 9258 SHEET '� OF 1 R Tel 94'-6' i8'-0' 20'-0' 20'-0' 20'-0' y 12'-6' -8& 5'-0' 22'-4' 501-08 SCALE 1 1/4' = V-0' 0 ZD W z u o w Q a a v pC3 in U p m w m x a ❑ A P° z n _j w • u n F ~ Z Z � o ST. LUCIE COUNTY BUILDING DIViSiON EVI EWEI) FOR COMPLIANCE .-VIEWED BY , PLANS AND AND PER! Piff Cw 41 is i P,r Kf PT, C?N 11 R ()P 'ic°��ctvr�' E COW—Ff. PiEPTE PREVENTION BUREAU CODE COMPLIANC 54655 DATE -�i SUBJECT TO: FT. PIERCE FIRE PREVENTION CODE VM CODE-401 ASHACS R 8 R Interior Fnhh Flame Spread Rating EXost Ways C1&SS1a 11.wnw1w* Other Areas Class .. . IVlink w p ND Cry s-i DRAWN CHECKED DATE AtP21 L O2 , 1993 SCALE DRAWING NUMBER SHEET HUNDER or 5 S v F __1 F -1 F_ __1 F - -1 18'-0' 20'-0' 20'-0' 20'-0' D —� -- D D D- I A A A A D I II I II E� Z a C C c 0 0 C3 � a a 0 0 I S-1 D In z x o - I E� II 1 — f11 0 w CONCRETE STOOP D o A A A iu A L— - �- --- ;o D D D D D I D I D N CONCRETE STOOP to D \' D O �0 N N S-2 n i 0 22'-8' LA �B� I B 1 I D I _ —D i O i I i � I CONCRETE STOOP �5'-0• 50'-0' - FOUNDATION PLAN SCALE 1 1/4' = 1'-0' C i A A 0 D FE I 5'-0' IL IL a o D = o 0 I WOD F- I I LJ Ln x � z z zo u F I co W N O �I ^ o� � ~ U0 ! o ID 3'-0• (TYP) I �o %o I 0 T L — FOUNDATION NOTES: FOUNDATION DESIGN IS BASED ON A UNIFORM SOIL LOADING OF 2500 POUNDS PER SQUARE FOOT. A FLORIDA REGISTERED TESTING ENGINEER SHALL PROVIDE A SIGNED AND SEALED WRITTEN REPORT OF ON SITE BORINGS VERIFYING ACTUAL SOIL BEARING VALUES GREATER THAN 2500 POUNDS PER SQUARE FOOT. IN ABSENCE OF SUCH REPORT, THE FOUNDATION DESIGN AND DETAILS SHOWN HEREON ARE VOID. FOUNDATION SCHEDULES: S-1 5" THICK 4000 PSI POURED CONCRETE WITH 6" x 6", #10/10 GA. WELDED WIRE MESH ON 6 MIL VISQUEEN OVER TREATED COMPACTED FILL. S-2 4" THICK 2500 PSI POURED CONCRETE WITH 6" x 6", #10/10 GA. WELDED WIRE MESH ON 6 MIL VISQUEEN OVER TREATED COMPACTED FILL. A 13'-6" x 5'-0" x 2'-0" DEEP 3000 PSI POURED CONCRETE FOOTING WITH #5 BARS @ 6" O.C. BOTH WAYS TOP AND BOTTOM. HOOK ANCHOR BOLTS UNDER MAT @ BOTTOM. B 4'-0" x 4'-0" x 2'-0" DEEP 3000 PSI POURED CONCRETE FOOTING WITH # 4 BARS @ 6" O.C. BOTH WAYS BOTTOM AND WITH # 4 BARS @ 1'-0" O.C. BOTH WAYS TOP. HOOK ANCHOR BOLTS UNDER MAT @ BOTTOM. C 1'-6" x 0'-10" DEEP 3000 PSI INTERGRAL POURED CONCRETE TIE -ROD FOOTING WITH 3 # 5 BARS CONTINUOUS. HOOK ENDS AROUND COLUMN ANCHOR BOLTS, TYPICAL EACH END. Z W o a- - C3 a � Cv� a C3 U m m c'I x a o A Ao z C3 • U U 4 ZZ y O d I! D 1'-6" x 0'-10" DEEP 3000 PSI INTEGRAL s-! POURED CONCRETE MONOLITHIC FOOTING WITH 3 # 5 BARS CONTINUOUS THROUGH ADJACENT ('.ly FOOTINGS. E 6'-0" x 6'-0" x 2'-0" DEEP 3000 PSI POURED CONCRETE FOOTING WITH # 4 BARS @ 0- 6" O.C. EACH WAY BOTTOM AND WITH #4 BARS C[ @ 1'-0" O.C. EACH WAY TOP. HOOK ANCHOR BOLTS UNDER MAT @ BOTTOM. DRAWN F 5'-6" x 5'-6" x 2'-0" DEEP 3000 PSI POURED CONCRETE FOOTING WITH # 4 BARS @ --- 6" O.C. EACH WAY BOTTOM AND WITH #4 BARS CHECKED @ 1'-0" O.C. EACH WAY TOP. HOOK ANCHOR BOLTS UNDER MAT @ BOTTOM. _- DATE G 4'-0" x 4'-0" x" 2'-0' DEEP 3000 PSI AMIL OZ, 199't POURED CONCRETE FOOTING WITH # 4 BARS @ 6" O.C. EACH WAY BOTTOM AND WITH #4 BARS SCALE @ 1'-0" O.C. EACH WAY TOP. HOOK ANCHOR BOLTS UNDER MAT @ BOTTOM. DRAWING NUMBER `� EET EN��iu NER 5 MEEM NORTH SCALE 1 1/8' = 1'-0' ELEVATION METAL ROOF urr w� ennr METAL ROOF m I cu fU METAL SIDING METAL SIDING g SOUTH ELEVATION SCALE 1 1/8' = 1'-0' n EAST ELEVATION SCALE 1 1/8' = 1'-0' METAL ROOF WEST ELEVATION SCALE 1 1/8' = 1'-0' L111 w I nnnr D I J Z W o u M W Q d L o U OD m OD M xa o A Z o O J M W i ♦ F u u V � n F- N 0 0 U d ml O N c RI on L N a IL 'C g g i U 4 f IL � Ma Y LL DRAWN CHECKED DATE APKIL 02, 1993 SCALE DRAWING NUMBER SHEET HURNFI- 3 OF 5 SHEETS 2' WHITE VINYL FACED INSULATION WITHIN CEILING OF WAREHOUSE METAL ROOF / GUTTER AND DOWN SPOUT SYSTEM i s i PRE - ENGINEERED STEEL STRUCTURE METAL SIDING i 8' GIRT METAL ROOF R-19 INSULATION 2' WHITE REINFORCED VINYL FACED INSULATION WITHIN WALLS OF WAREHOUSE 2 x 2 ACOUSTIC CEILING SUSPENDED FROM STRUCTURE R-11 INSULATION > 5/8' TYPI_ 'X' DRYWALL BOTH SIDE-S, 1 HOUR FIRE WALL SEPARATION `— 2 x 4 STUDS 2 16' O,C, SLAB AS --, SLAB AS SCHEDULED / SCHEDULED FOUNDATIONS AS SCHEDULED WALL SECTION "A" SCALE 1 1/2' = 1'-0' METAL ROOF - PRE - ENGINEERED STEEL - STRUCTURE ,- R-19 INSULATION 2 x 2 ACOUSTIC CEILING SUSPENDED FROM STRUCTURE R-11 INSULATION- 1/2' DRYWALL SLAB AS — SCHEDULED FOUNDATIONS AS SCHEDULED GUTTER AND DOWN SPOUT SYSTEM - METAL SIDING N n i If 9 1/2' GIRT 2 x 4 STUDS 2 16' O.C. FINISH GRADE WALL SECTION "B" SCALE 1 1/2' = 1'-0' PRE STRL WALL S SCALE 1 1/2' = 1'-D' 2' WHITE VINYL FACED INSULATION WITHIN CEILING OF WAREHOUSE ER AND DOWN T SYSTEM ECTION " C" aL SIDING Z Ua dUWImx ix vacAWa ❑ ZM o J� ❑F u L.Wr- Z o 2 METAL ROOF PURLIN R-19 INSULATION 2 x 2 ACOUSTIC CEILING SUSPENDED FROM STRUCTURE m� c .c o yl l v F_3 w c 1/2' DRYWALL BOTH SIDES °D ON 2 x 4 STUDS 2 16' O.C. a le SLAB AS SCHEDULED m v si WALL SECTION "D" SCALE 1 1/2' = 1'-O' �H CL DRAWN CHECKED DATE APIZI L 02, 199 > SCALE DRAWING NUMBER 4 B-11 B-24 I �> A-1 A-2 B-13 PC 1 B-9 1 B-26 ® B-7 CEE] 0 O.P 9LF61 To FAA'NLL \ ' eLvh eY FP!. ELECT. . METER FMFIR B-7 PANEL JB- COND. FFW/H:; A/C m "� IEF CONCRETE PAD aS 10 WELDER 208 V B-15,17 _ --- -- B-22 c 20 TON HOIST .,O B-12 i B-7 �FO 0 0 O B-13 PC 0 O :.' WELDER WELDER 208 V 208 V X, B--19,21 B 23,25 B 20 �,/ 400 n PANEL'. 'A! MAINS. CIM.L.O. MAiN BR 1q TYPE. SQ. I I D " or ITE BUS RATING, 0 w MOUNTING. LI RECESS $I SURFACE VOLTAGE, 22144#0 3/a0 KT. p 0 AMPS DESCRIPTION CKT N0, JPOUdAMPSI DESCRIPTION ci SD �O"jo.- mol"I (2o«v) 2 3 Qo to ioN A61sT (louv� 3 4 5 6 7 Z 90 �C �p FAnEL'6`(7.M tF� 8 ZU :YC 'K is 9 10 l 1 12 13 1 10 SpN c6 14 15 16 18 20 22 k 24 26 28 y 30 E-1 2 2 0 O GFI EF i 2 B-3 - - - 6 6 FI AO AO AO 2' F -- LIGHTING FIXTURE SCHEDULE A LIGHTOLIER XT2GVA 440-LE WITH (4) - F40 T12 CW. B LIGHTOLIER XTIFVA 240 - LE WITH (2) - F40 T12 CW. C LIGHTOLIER 5488 WITH (2) - F40 T12 CW. D LIGHTOLIER 6919 WITH (2) PL-13, 2700K. E LIGHTALARMS UXE8WRW - FL F LIGHTALARMS CA-2. G LIGHTOLIER 1100 IC/1178SH WITH 40W A19. H STONCO WP250MA WITH 250W M.H.-r OcloBELL 0FERATED- J LIGHTOLIER KWS 296SL - LE - KNA - AH5 WITH (2) - F96 T12 CW - MOUNT AT HEIGHT SELECTED. j 10 TON HOIST NOTE 1 PROVIDE POWER BUS TRACK FOR HOIST POWER (TYPICAL). Yp •1P aY^+ �J) B-14 O B-7 PANEL: I'5" MAINS. JAM.L.O. AMAIN BR TYPE. SQ. "D" or ITE BUS RATING. w 5� MOUNTING, Zi RECESS SURFACE VOLTAGE, o 0 KT. p 0 AMPS DESCRIPTION CKT NO. P AMPS DESCRIPTION 20 L-T,, 2 to kE�pi'5 3 4 5 6 7 B 9 10 11 12 13 W 14 15 Z SD wtiv��:d 16 17 19 2 5p 21 23 2 50 L2817- 25 27 2 30 N T 7,, A o APd29 31 2 A/c- G.II 32 FA G.E 34 35 I 2p S F" EF 36 37 38 39 40 =V4cE y 42 0 ELECTRICAL FLOOR PLAN SCALE 1 1/4' = 1'-0' U ELECTRICAL NOTES: CL ALL ELECTRICAL INSTALLATIONS ANDEQUIPMENT SHALL BE IN ACCORDANCE WITHroTHE FZ3 REQUIREMENTS OF THE N.E.C. (NFPANO. 70) AS AMENDED, AND ALL LOCAL &STATE CODES IN FORCE AT THE TIME OFoCONSTRUCTION. M GROUND SYSTEM IN ACCORDANCE WITHLARTICLE 250 N.E.C.B-18 SYSTEM VOLTAGE SHALL BE 277/480 AND120/208 VOLT SINGLE AND THREE PHASE. a PANELBOARDS AND LOAD CENTERS SHALL BE IITE, SQUARE 'D' OR APPROVED EQUAL. ALL CONDUCTORS AND BUS BARS SHALL BE immumommmommmmmmmmmemm COPPER. IALL MATERIAL SHALL BE U.L. APPROVED. PROVIDE ALL NECESSARY PREMITS REQUIRED. n / PROVIDE TEMPORARY SERVICE FOR USE BY ALL TRADES DURING CONSTRUCTION. PROVIDE A TYPEWRITTEN DIRECTORY FOR EACH PANELB ARD OR LOAD CENTER. Fl CONTRACTOR SHALL MAKE FINAL ARRANGEMENT FOR ELECTRICAL AND TELEPHONE ERVICE. VERIFY TRANSFORMER LOCATION At D SERVICE POINTS FOR ALL UTILITIES P IOR TO BIDS. PROVIDE PULL STRING IN LL EMPTY TELEPHONE AND SOUND SYSTEM CONDI IT. PROVIDE LI HTNING ARRESTOR ON MAIN SERVICE - I E OR EQUAL. J 29 FEEDER SCHEDULE: MAIN SERVICE (4) - 500 MCM THW IN 3-1/2" C MA1� SE(?�IGE FEED XMFR (F1) 3 # 3 THW IN 1-1/4" C FEED PANEL B (F2) 4 # 3/0 THWN & #4 CU GRND IN 2" C F� ?AµiL rA N E L a rc wv J 7SkvA yIFZ PI NFR- 2��/4•e � PIL1 sew [}'I4OU5EKEE►lL41 17/a 7 #`f cLi ya„p. ELECT. DIST. DRAWN CHECKED DATE API''-1L 02, 1991 SCALE DRAWING NUMBER SHEET NUMBER OF `� MFEYS