Loading...
HomeMy WebLinkAbout350 NORTH ROCK ROCK PAPERWORKT F%tr 9FFICEl7SE;ONL'Y: WAal:floc 45 Bab DATE FILED: 414 PLAN REVIEW FEE: 4a R CEIPT NO.: CONCURRENCY FEE: RECEIPT NO.: `-- ---1, PERMIT NUMBER" - ALL 'INFO MAST BE COMPLETE at FILLED IN TO BE ACCEPTED ��e coy ST. LUCIE COUNTY PUBLIC WORKS BUILDING & ZONING DEPARTMENT- SCANNED 2300VIRGINIAAVE NUE _ BY O tOp FORT PIERCE, FL 34982=5652 St, Lucie County 561-462-1553 APPLICATION for BUILDING PERMIT CERTIFICATE of CAPACITY/ZONING'COMPLIANCE PROJECT INFORMATION 1. LOCATION/SITEAD/D/RESS: 3tJ0 ROGK ROAD, YT ��/2�, /—G 2. S/D NAME: SITE PLAN NAME: .oat z/4AIV 4;ON64kEr2F 141.0. 3. PROPERTY TAX ID 4. LEGAL DESCRIPTION (attach extra sheets If necessary): S��' I&W/Eb 7. BLOCK, , 8„ LOT BOOK NO. NO. , :_ �_" \ NO. _ 9. PARCEL SIZE: ACRES/SQ FT. It-OQGwl LOT DIMENSIONS 10. DESCRIPTION OF CONSTRUCTION PROJECT OR,WORK,ACTIVITY: GoNI1aUGT /IIEGV 1141A.,rdAnfr 4", .1AdA//.Q`TG tl: 0.iw%/a `A .,Z/7Y' 11. SETBACKS (ACTUAL) FRONT: 9�, BACK: Oy! 181DET' SEFT DE: �/• O r 12. TYPE OF CONSTRUCTION (Check all appropriate boxes) NEW CONSTRUCTION [ ] RESIDENTIAL [ ] OTHER (SPECIFY) [ ] EXPANSION/ADDITION [ ] COMMERCIAL [ ]. INTERIOR RENOVATION [ ] INDUSTRIAL 13. DESCRIPTION OF,PROPOSED USE:. wNGf�C7•G . (�A57//VC7,\ �/i�/L/.% J 14. Sq. Ft./CONSTRUCTION: 16. VALUE OF CONSTRUCTION % $�� 00 The value of construction is used to determine the amount of permit fees to be assessed. St Lurie County reserves the right to question and/or modify the Indicated value of construction if it is demonstrated that the submitted figures are not coitsistent with similar types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted with this application. 1#Ics -,VA i d I SLCCDV Form No.: 001-02 THE AVERAGE PROCESSING TIME FOR MOST BUILDING PERMITS IS TEN (10) WORKING DAYS OWNER INFORMATION: NAME: ADDRESS: _ /yu N. W/UK t^gAV CITY: rG'�QG�/ STATE: 04seglDld ZIP S 9� PHONE (DAYTIME): rr.6I1 Y,�l18 / IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE, PLEASE FILL IN NAME AND ADDRESS BELOW. FEE SIMPLE TITLEHOLDER: RoPJ �• __SwOWE _ ADDRESS: CITY: Ooar Sr L�G�e PHONE (DAYTIME): (56/_ i/87_ CONTRACTOR INFORMATION• ST. of FL REGJCERT #: BUSINESS NAME:. QUALIFIERS NAME: ADDRESS: CITY: PHONE (DAYTIME): ARCHIT/ENGINEER: ADDRESS: CITY: PHONE (DAYTIME): BONDING COMPANY: ADDRESS: CITY: r5�iS �f6/- S 3 3y VERo .6b/1 51�9-/25� • A6 STATE: A�ZQ/DA '$T'. LUCIF-COUNTY CERT #:•- FAX NO. �J6�'• 7�f✓7' T SPATE: • /�ra�UH ' •ZIP STATE: ZIP MORTGAGELENDER: , • f IASL 1*1aAl A,,,47-161Y,4G ,DANK Or 1440F21PA ADDRESS: CITY: �ar /ri'�' _ STATE:. Aliapwm ZIP �V050 IMPORTANT NOTICE: When a permit is issued and it Is not picked up within 60 days after notification it will be voided and returned to you by mail. CERTIFICATION: This application is hereby made to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits may be required for ELECTRICAL, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AND AIR CONDITIONERS, ETC., not otherwise included with this building permit application. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures (all types), swimming pools, fences,.walls, signs, screen rooms,'utility substations & accessory uses to another non- residential use. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPLICANT: AS THE APPLICANT FOR THIS BUILDING PERMIT, IF IT IS NOT YOUR RIGHT, TITLE, AND INTEREST THAT IS SUBJECT TO ATTACHMENT; AS A CONDITION OF THIS PERMIT YOU PROMISE IN GOOD FAITH TO DELIVER A COPY OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. r\I I OWNER/C NTRACTOR SIGNATURE CONTRACT R SIGNATURE STATE OF FLORIDA COUNTY OF S7 LUe!& The foregoing inment was acknowledged before me this 2 day of AfA)L, 20-0/ , by �&(AU5 DAUI S , who is personally known to mgor who 7has roduced as identification: ignature of Notary ao&,op- A Awo(r Type or Print Name of Notary Notary Public Title STATE OF FLORIDA COUNTY OF S% Zbe,10 The foregoing in was acknowledged before me this =� day of c 4 . 200/ , by f//4W MV/f , who is personally known to me or Mo has produced as identification. ,$igfiature of Notary e4&&AQ. d GR"''fir Type of Print Name of Notary Notary Public Title GCg758T Commission Number Commission Number nt ,``tiPArp"�4 Ro �r A. del®t�E o``� d"%Roger A Ari®et (seal) _ ° �� Comt�slon # CC 971597 (seal) Commisslon # CC 971597 seal g seal ,. cy a� Expires Nov. 7,2004 a� ExPlm Nov. 7,2004 Bonded Thra Bonded Ttun ,�ii�`• Atlantic Bonding Co., Inc. �i9;',rj�� Atlantic Bonding Co., Inc. NOTE: TWO (2) SIGNATURES ARE REQUIRED. EACH SIGNATURE MUST BE NOTARIZED. IF APPLYING FOR THIS BUILDING PERMIT AS AN OWNEW- BUILDER, THE OWNER MUST PERSONALLY APPEAR TO SIGN THIS APPLICATION IN THE OFFICE LISTED ON THE FRONT OF THIS APPLICATION. BP #: d 1Q,6'0394 IN SECTION: J TOWNSHIP: 35 RANGE: •J' MAP NO.: v ZONING: / ! / LAND USE: LOT CVG %: TAZ NO.: FLOOD ZONE: FIRM MAP #: 1ST FLR ELV: MAX HGT: CST TYPE: OCCP TYPE: MAX. OCCP: # OF FURS: WATER: S ER: SPRINKLERS STORMWATE R LOT OF REC (befr 1/90) LOT OF REC (aftr 1/90) LOT SPLIT LOT SPLIT REQ'D APPRV'D DECAL LIBRARY PARKS PERMIT NUMBER IMPACT FEE IMPACT FEE FEE REPORT n ( PUBLIC BLDG. / ([ 1 0 HABITABALE FYADON FEE �r CODE U �p` !/ IMPACT FEE n.. lb D AREA I (RADON) .I,00 G L CREDIT Y N TOTAUROAD ROAD 111 {M QSS,ROAD D IMPACT ZONE 11VMMM'"'___/ IM ACT FEE" J IM♦iACT'FEE' DUE SCHOOL CREDIT ',' �. TOTAL IMPACT FEE - SCHOOL " IMPACT FEE POLICE FEE FIRE FEE pD, MISC FEES: TOTAL POLICE/FIRE/ ' ... 1.. ,, MISC.,-FEES Y N l ADDITIONAL SPECIFY: `'� tag ` TOTAL ALL PERMITS FEES REQ'D IJ L,� C_ REVIEWS'. ZONING ZONING PLANS VEGETATION.. SEA''"''. MANGROVE REVIEWED BY EXAMINING TURTLE ,i DATE• 1i COMPLETE I INITIALS �� �iN�aiGAN GONE- /N0. ST. I.UCI�COUNTY PUBLIC WORKS BUILDING & ZONING DEPARTMENT BUILDING PERMIT SUB -CONTRACTOR SUMMARY SCANNEU BY St. Lucie COuntV %AVI f 6',a7NX GoRP• will be using the (companylndividualname) Z3//- following sub -contractors for the project located atGYiIY ROAD (street address or property tax ID #) It is understood that if there is any change of status regarding the participation of any of the sub -contractors listed below, I will immediately advise the Building and Zoning Department of St. Lucie County. Trade Name of Company/Contractor St. Lucie County/ State of Florida License Number al06039 Plumbing SA/EED PI-IIA IAtl', INC. 9// OS6E611-A I>Q• G�Go�j02( 9070 .�/S Electrical 1�0ES �GyGGj�z/G y�i �jiQGNE,e PL. �QQ,�9122 04z267 7 HVAC/Machaniral S�Aao�i�/,e CeAlp voNlN6 5207 ND(/,StR/AG 310 fr GQGlo A *" ,828 3 .392 Roofing i�/ZE- LNG/N�E�D �T�. �ooa � AQo !f 1Qll/s e oewo-• GG Go33g y'� Gas St. Lucie County/ Trade Name of Company/Contractor State of Florida License I II r �%/GAN GONG INO• Sr. LUCIE COUNTY DEPARTMENT OF COMMUNITY DEVEwPMENTS Q 3UrLDING PERbW St. ute SUB -CONTRACTOR AG iT St l u�, (59,Y ' , SG Lode Cowny Camraaor Cert flmWon Nwnber. Srme of Florida Cetfieffiion Nwnber 0 q*A W): SNEED PLUMBING, INC. the PLUMBING Mawu7oaimu for the project larared at 9070 CF C043026 has agreed to be sub-eorttractor for R�G�P A' AWIZr &FNlr —^ pwe. of rlr pdrm oerRActa� !-• /30 _0000 -L9wll Of . B is understood that. if there is any change of status regarding our participation with the above mentioned project, I will immediately adviis the Community Development . Departmern (Growth Management D'nnision) of St. Lucie County by personally cling a Change of Contractor Form (SLC=V FOAM NO. )iD44q. BUSINESS QUALIFIER dogm:•t: GLENN M SNEED bushum name: address: CKYA Air. per: paw 0 1 1 Sam aM y4 ot/oi das o4l wewir Come-mrx Iwo ST. LUCIE COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING PERMIT SUB -CONTRACTOR AGREEMEN St. Lucie County Contractor Certification Number: State of Florida Certification Number (if applicable): or- S/ I -ye £ (companyfindividual name) T SCq j4 ED 3t �4cie r%_ o y�6 i y F P boo 91'z2 has agreed to be the i AGZ/ora L sub -contractor. for 2 K• Drw r S. (type of construction trade) (name of the prime contractor) 231! '1 0- 0000.&M/1 for the project located at 3-150 Ab C-k AW D It is understood that, (street address or property tax ID #) if there is any change of status regarding our participation with the above mentioned project, I will immediately advise the Community Development Department (Growth Management Division) of St. Lucie County by personally filing a Change of Contractor Form (SLCCDV FORM NO. 004-00). •HNMf111NRNRRMNN11f1fINN111MIRIfMIMN11RMRf 111f»1»1«f»b«ff If«11f BUSINESS QUALIFIER (original signatures required): signature print name ate business name: address: city,state,zip: phone: SLCCDV FORM NO.: 002-00 PERMIT # I I ISSUE DATE �iyl�RiGAN GONG . /ND ST. LUCIE COUNTY DEPARTMENT OF COMMUNTTY DEVELOPMENT BUILDING PERMIT SUB -CONTRACTOR AGREEMENT S�gNNEp 3t Lucie C01117tv St. Lucie County Contractor Certification Number: State of Florida Certification Number (if applicable): K.HNf1111Nf1R.HHf11111k111Hfilt11Nf1f. , SEA. CAST AifL ayMoAlikc has agreed to be (companyMdividual name) the "VAC sub -contractor for Q 1�-r ' AV'S C*NST aAp' (type of construction trade) (name of the prime contractor) for the project located at 35o N t496& AMP It is understood that, (street address or property tax ID #) if there is any change of status regarding our participation with the above mentioned project, I will immediately advise the Community Development Department (Growth Management Division) of St. Lucie County by personally filing a Change of Contractor Form (SLCCDV FORM. NO. 004-00). 1fifHNIf11HH1N111N1N1tliHfif1111N11Nif11N1H11fINN1N1K111111H1NK1K ' USI ESS/QUALIFIER (original signatures required): 4 .Leh.► V. Lkntc,�t� 05 O/ O/ signatu print name �6ate business name: �� �n CoNDI RoAtfdC� address: 3207 Wea5T/LM-r— 3/5r ST. city,state,zip: Fat / FL 3N9�fla phone: W0W/' 3' )5T/ SLCCDV FORM NO.: 00: PERMIT # ISSUE DATE 00 A fwcaN Go oturaE INP • ST. LUCIE COUNTY PUBLIC WORKS BUILDING & ZONING DEPARTMENT BUILDING PERNUT SUB -CONTRACTOR AGREEMENT St. Lucie County Contractor Certification Number. State of Florida Certification Number (if applicable): SC q St 4Uci8Co�0 — 4htY cG GO-'355:_ /•C'GV/AAP Ir, AA1115 CORP- has agreed to be (company/individual name) the &67A6 AMG/NCB sub -contractor for lllmfi _L 11�cr (type of construction trade) (name of the prime contractor) 23//— cry/i for the project located at i55Q Al Ajg�-k- A4-6 It is understood that, (street address or property tax ID 0) if there is any change of status regarding our participation with the above mentioned project, I will immediately advise the Building and Zoning Department of St. Lucie County by personally filing a Change of Contractor Form (SLCCDV FORM NO. 004-00). BUSINESS QUALIFIER (original signatures required): %Ol/GGAI AAA Ild 05 Ol p/ signature Print name Date business name: R6114,eD At' 44W Go VWX c"4AR- address: P• O• /AA city,state,zip: XA O MA phone: 6/-116/-AS96 DFFICE?USEPNVY: SLCCDV FORM NO.: 002 PERMrr 9 ISSUE DATE 00 L 1WA14A/V 61WA572,5 /ND. ST. LUCIE COUNTY PUBLIC WORKS BUILDING & ZONING DEPARTMENT 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 561-462-1553 FILLED LANDS AFFIDAVIT SCQyNFO St tUCie COpn ty I, the undersigned, am the owner of the following described property, 350 i1/ ��X !?aAn 2--►1- l30- I (tax IDnegal descriptioNaddress) for which I have applied to St. Lucie County for a Final Development Permit. In accepting this Final Development Permit, BP Number a/ . I acknowledge that as owner of the above described property, and in accordance with Section 7.04.01(D), St. Lucie County Land Development Code, I shall be responsible for assuring adequate drainage so that the immediate community WILL NOT be adversely affected. I further acknowledge that in granting this permit for the development of this property, St. Lucie County is neither obliged nor liable to provide for, or maintain in any form, adequate drainage off my property which will not adversely affect the immediate community. lzongpr L. x 05/01101 Property Owner Property Owner Date (Print) (Signature) STATE OF FLORIDA, COUNTY OF JT 416146 SWORN TO AND SUBSCRIBED BEFORE ME THIS DAY OF �ilY , 206" , BY Od�2T G • Uii%OH�E WHO IS PERSONALLY KNOWN TO ME OR WHO HAS PRODUCED AS IDENTIFICATION (seal) 10 TURE OF NOTARY TYPE OR PRINT NAME OF NOTARY l ;,tVllU� Roger A. Priest Co XPIMoNo . 79715ti7 NOTARY PUBLIC TITLE CC97/5B 7COMMISSION NUMBER �0 a� Explras Nov. 7,2004 �9 Hooded TLm O�Fan�i�P , Ad4n0e Bonding 0o. B10. SLCCDV FORM NO.: 011-00 LEGAL DESCRIPTION: BEGINNING at a Concrete Monument at the Southeast earner of the Northwest 114 of the Northeast 114 of Section 11, Township 35 South, Range 39 East,, St. Lucie County, Florida; thence run South 89 degrees 49'03" West, along Ilse South line of the said Northwest 114 of the Northeast 114, a distance of 1368.32 feet, to a Concrete Monument on the East right-of-way of Rock Road and being 25 feel East of the West line of the said Northwest 114 of the Northeast 114; thence run North 00 degrees 07'28" West, along the said East right-of-way, a distance of 31S.74 feet, to a Concrete Monument; thence run North 89 degrees 36'20" East, a distance of 1369.00 feet, to a Concrete Monument on the East line of the said Northwest 114 of Ilse Northeast 114; thence run South 00 degrees 00'17" East, along the East line of the said Northwest 114 of the Northeast 114, to the POINT OF BEGINNING, all lying and being in Section 11, Township 35 South, Range 39 East, St. Lucie County, Florida, containing 10.00 acres, more or less. TOGETHER with a nonexclusive easement for drainage purposes across the East 20 feet of the following described real property: The Northwest 114 of th'e Northeast 114 of Section 11, Township 35 South, Range 39 East, excepting therefrom all rights of way for drainage canals and public roads, and less and excepting therefrom the following described property: BEGINNING at a Concrete Monument at the Southeast corner of the Northwest 114 of the Northeast 114 of Section 11, Township 35 South, Range 39 East, St. Lucie County, Florida; thence run South 89 degrees 49'03" West, along the South line of the said Northwest 114 of the Northeast 114, a distance of 1368.32 feet, to a Concrete Monument on the East right-of-way of Rock Road and being 25 feet East of the West line.of the said Northwest 114 of the Northeast 114; thence run North 00 degrees 07'28" West, along the said East right-of-way, a distance of 315.74 feet, to a Concrete Monument; thence run North 89 degrees 36'20" East, a distance of 1369.00 feet, to a Concrete Monument on the East line of the said Northwest 114 of the Northeast 1/4; thence run South 00 degrees 00'17" East, along the Past line of the said Northwest 114 oflhe Northeast 114, to POINT OFBEGINNING, all lying and being in Township 35 South, Range 39 East, St. Lucie County, Florida, and containing 10.00 acres, more or less. 19HT-11—eU01 11J+09 WLLIMU bKUWH G IHLUWCLL J01 Coo O4.o JOANNE HOLMAN, CLERK OF THE CIRCUIT COURT - SAINT LUCIE CUUNI'Y o° hnr?' 1 File Number: 1912281 OR'OOOK 1391 PAGE 1770 cD Rel.Nrded;05i3.1/01 09:21 PREPARED BY: Richard K. Davis Construction Corp. STATE OF FLORMA P. 0. Box 186 ST. LUCIE 000 NTY Ft. Pierce, FL 34954 THIS ISTOCERTIFY THAT THIS ISA � ;. /• 1LE'I'URN T0: TRUE AND CORRECT COPY OF THE ORIGINAL. o • ,w ,i; '0'' i'�I'* '{ Sc.QA, Calvin B. Brown, Fsy. C� •{.�%�? �VV x '-' •;15 �' �' F� Collins, Brown, Caldwell, JoAN E HOL IC +,• ;, "> Barkett & Gamvaglia, Charlcmed ' '`'r . r !f C�C� P. O. Box 64.3686 R. (y C e't'e Ov K erx? , Vero Beach, FL 32964-3686 " — I Date~� I�����> ' Permit No. Slate Or �L0Q1 NOTICE OF COMMENCEMENT Tax ID 2011-lAv"i9ex- I County Of .S. 610 Till: UNDERSIGNED hereby gives notice that improvement will be made to certain real property, and in accordance with Chaptcr 713, Florida Statutes, the following Information is provided In this Notice' of Commencement, Legal Description of property and street address, if available_sa Yifl}iGWIO Iff-W S1 T;%r i Surety _AMA Phone Address Fax H Amount of Bond E Phone H Fax ff_ Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13 (1) (a) 7., Florida Statutes: Name -` Ph6e0 Address Fax H In addition to himself, owner designates of (Phone H Fax H ) to receive a copy of the Lienor's Notice as provided in Section 713.13(l)(b), Florida Statutes. Expirallon date of notice oreommenccment is one year from the dale of recording unless a different date is specified. OWNERS SIGNATURES STATE OF FLOIUDA, COVNTYOF Sr L//(i/� Acknowledged before me this [ day of A,f4y_, 20pL,by.R0�IE>=i L•>.�iil/_f, who is personally known In me or who has produced as identification. sea$O ! A. PlletR 41-- i,A&11 TUAE OF NOTARY cdoodccs71de7 .4o6E.Q A• F?3/FJT • �-c BooAed jy = TYPE OR PRINT NAME OF NOTARY N4ulle MaAln1 6. Ina NONPUBLIC TITLE 46ffZe=7 COMMISSION NUMBER Post-IrFax Nato 7671 pa+er , . 1 _. wo.>► • ,—ter To Fromal comeFt. Cn. nxane a Fl+Mu N rw a (� I 1 C OO Fax a ST LUCIE COUNTY ROAD IMPACT FEE CALCULATION FORM DATE NAME OF FEEPAYER ADDRESS: PERMIT #: "",/ 050394� ROADIMPACT SCq St Cobh THE IMPACT FEE CALCULATED HEREIN HAS BEEN DETERMINED BASED ON THE FEE SCHEDULE ADOPTED ON 5-09-00, EFFECTIVE 10-01-00. IMPACT FEE CALCULATIONS t�� LAND # OF UNITS: v USE TYPE: # SQ FEET (PER 1000): /J0 (# SQ FT - BY 1000) X ( FEE PER UNIT) = ($) /1oe6 x .�" = $ -6490 PUBLIC BUILDINGS: /5 x 3�_$ egoCIO FIRE / EMSV,�Q X /�S °� _$ adZS `O St. Lucie County Property Record Card Page 1 of 4 St. Lucie County Property Appraiser Geographic Information Services Real Property Record for Parcel Number: 23l_11,2300010006 Record Number: 1 of 3 Location: 350 N ROCK RD CTY ### Section: 11 Township: 35S Range: 39E s C Show Location Mau Owner, Legal Description, Deed & Total Assessment Name: SNOWE, Legal: 1135 39 BEG AT SE COR OF NW 1/4 ROBERT L OF NE 1/4 RUN S 89 DEG 49 MIN 03 Address: 10115 Bay Tree SEC W ALG S LI OF SD NW 1/4 OF Ct NE 1/41368.32 FT TO E R/W OF Port St Lucie, FL 34986- ROCK RD,TH N 00 DEG 07 MIN 28 SEC W ALG SD E R/W 3201 315.74 FT,TH Book: 0775 Page: 2661 Sale Date: 1992-01-31 00:00:00 Sale Amt: 250000 Sale/FT: 52.63/SgFt. Insp. Date: By: Date Valued: Permits: C95-110628 Exempt.: 0 Land: 196000 Improve.: 180900 Class: 0 Total:376900 Taxable:376900 Neighborhood & Use lilSubdivName: Neighborhood:490 Map-ID:23/11N IDOR Use: 4000 General Building Data Type:ID EE Year Built: 1993 Eff: 993 Baths: 0 ��❑❑❑ Bedrms: 0 Pool: N Fp1c: N Air: N Living Area: 4750 SgFt. Wall: Sheet Metal Building Perimeter Sketch and Photograph m r, aa, a � Improvements Improvements / Extra Features No. Code/Cat Size 0 OHD - 452 1993 No. Code/Cat Size BAS -BASE AREA 4750 0 ASPl- 8580 1993 http://www.pasle.org/webmap/scripts/Pre.pl?l 1472539,231112300010006 5/21/2001 0 REQUEST FOR 30 DAY TEMPORARY POWER RELEASE DATE: PERMIT NUMBER: v 00 r PROPERTY ADDRESS: MOVEE M EN 2 2 2002 St, Lucle County Public Works ST. LUCIE COUNTY BLDG. & ZONING 2300 VIRGINIA AVE FORT PIERCE, FL 34952-5652 Ph. (561) 462-2165 AX (561) 462-1148 SCANNED St.. L x, County THE UNDERSIGNED HEREBY REQUEST RELEASE OF ELECTRICAL POWER TO THE ABOVE DESCRIBED PROPERTY, FOR A PERIOD NOT TO EXCEED THIRTY (30) DAYS, FOR THE PURPOSE OF TESTING SYSTEMS AND EQUIPMENT IN PREPARATION FOR FINAL INSPECTION. IN CONSIDERATION OF APPROVAL OF THE REQUEST WE HEREBY ACKNOWLEDGE AND AGREE AS FOLLOWS: 1. This temporary power release in requested for the above stated purpose only, and there will be no occupancy of any type, other than that permitted by construction during this time period. 2. As witness by our signatures, we hereby agree to abide by all terms and conditions of this agreement, including Building Division Policy, which is incorporated herein by reference. 3. All conditions and requirements listed in the attached document entitled "Requirements for 30 Day Power for Testing" have been fulfilled and the premises is.ready for compliance inspection. WE HEREBY RELEASE AND AGREE TO HOLD HARMLESS, ST. LUCIE COUNTY, AND THEIR EMPLOYEES FROM ALL LIABILITIES AND CLAIMS OF ANY TYPE OF NATURE WHICH MAY ARISE NOW OR IN THE FUTURE OUT OF THIS TRANSACTION, INCLUDING ANY DAMAGES WHICH MAY BE INCURRED DUE TO THE DISCONNECTION OF ELECTRICAL POWER IN THE EVENT OF VIOLATION OF THIS AGREEMENT. OWNER SIGNATURE ��HARo P4111f CttaN(r Cow GENERAL CONTRACTOR-SIG5A7URE , is ELECTRICAL CONTRACTOR 5614657665 R.K. DAVIS February 27, 2002 -Mr. Dennis Grin INAA711A 'Code Compliance Manager St. Lucie County Building Department 2300 Virginia Avenue Fort Pierce, Florida 34982 841 P01 FEB 27 102 10:48 Oa 00130u4 • P.O. BOX 100 • FT. PI@ROH, FLORIOA 340R4 . Zr; Am-,rican Coii'crete Industries Building Permits # li850499 & 21050394 Dear Dennis: i1. K. Davis Construction Corporation would like to request an extension on the 30-day temporary power to the above referenced permits so that we can resolve some site improvement issues and obtain final site inspections for a Certificate of Completion. This request is for a fourteen -day extension only. We anticipate that the site issues are going to be resolved by next Wednesday, March 6th and final site inspection will be cquested thereafter. Please do not hesitate to call on me with any questions or concerns you may have. S,.ereiy> f Roger A. Priest Project Manager Cc. Robert L. Snowe American Concrete Industries A19S119 FEB 2 7 2002 st, Lucie County Public Works -- VA=T:N,. ST. LVCIE$61-401-0330 • INDIAN RIVER 001-770-0180 -FAX 661-406-7600 • WWW.RKOAVIB.COM �h$ '� Al-�;�-4 0 /cJ`os%7 - b E &T DUNKELBERGER ENGINEERING & TESTING, INC. , 1 M Project Name: New Manufacturing Building Report t�UCle y 08-24-01 American Concrete Industries Facility County Client Name: American Concrete Industries 350 N. Rock Road Project No.: 01-10-1053 Ft. Pierce, FL 34954 Date Tested: 07-24-01 Technician Initials: SM Attn: Mr. Bob Snowe Progress Report No.: 2 Sheet 2 of 6) Laborator r Proctor Field Tests Test No. Probe Depth in Maximum Dry Density c Optimum Moisture % Dry Density c Cone Resistance' is Moisture % Minimum Required Compaction % Percent Maximum Density Test Result 1 12 110.7 12.4 109.5 ... 12.9 95 98.9 Pass 2 12 110.7 12.4 110.2 ... 12.2 95 99.5 Pass 3 1 12 1 110.7 12.4 109.8 ... 12.5 95 99.2 Pass Type of Field Density Test: ( X ) ASTM D 2922 ( ) ASTM D 2937 Minimum Required Compaction Based on: (X) AASHTO T-180 (ASTM D 1557) ( ) AASHTO T-99 (ASTM D 698) Compaction percent estimated from cone penetrometer reading obtained with a Brainard-Kilman Model S-214 hand-held cone penetrometer. Test No. Soil Type Elevation Test Location 1 10 0-12 Footing, line A between lines 2 and 3 RETEST of #1, 07-19-01 2 10 0-12 Footing, line A between lines 6 and 7 RETEST of #2, 07-19-01 3 10 0-12 Footing, line A between lines 10 and I I RETEST of #3, 07-19-01 Elevation Referenced to: ( ) NGVD ( ) MSL Soil Type 1 Structural Fill 2 Final Grading Fill 3 Mass Grading Fill 4 Utility Backfill - Sanitary 5 Utility Backfill - Water 6 Utility Backfill - Storm 7 Roadway Subgrade 8 Stabilized Subgrade 9 Base Course 10 Other: Footing Excavation cc: PUG � 8 2pp1 (X) Other Inches below bottom of footing �O� uo�e CoCraig E. Dunkelb FL Registration 1 523A NW Enterprise Drive, Port St. Lucie, Florida 34986 • Phone: (561) 343-9787 • Fax: (561) State of Florida Board of Professional Engineers Authorization No. 6870 D E &T DUNKELBERGER ENGINEERING & TESTING, INC. SOIL DENSITY TEST REPORT Project Name: New Manufacturing Building Report Date: 08-24-01 American Concrete Industries Facility Client Name: American Concrete Industries 350 N. Rock Road Project No.: 01-10-1053 Ft. Pierce, FL 34954 Date Tested: 08-1-01 Technician Initials: SM Attn: Mr. Bob Snowe Progress Report No.: 2 Sheet 3 of 6 Laborator r Proctor Field Tests Test No. Probe Depth in Maximum Dry Density c Optimum Moisture % Dry Density c Cone Resistance' is Moisture % Minimum Required Compaction % Percent Maximum Density Test Result 1 12 110.7 12.4 114.1 - - - 11.5 95 100+ Pass 2 12 110.7 12.4 113.2 --- 12.1 95 100+ Pass 3 12 110.7 1 12.4 112.5 - - - 12.6 95 100+ Pass Type of Field Density Test: ( X ) ASTM D 2922 ( ) ASTM D 2937 Minimum Required Compaction. Based on: ( X ) AASHTO T-180 (ASTM D 1557) ( ) AASHTO T-99 (ASTM D 698) 'Compaction percent estimated from cone penetrometer reading obtained with a Brainard-Kilman Model S-214 hand-held cone penetrometer. Test No. Soil a Elevation Test Location 1 10 0-12 Footing, line D between lines I and 2 2 10 0-12 Footing, line Dbetween lines 5 and 6 3 10 0-12 Footing, line D between lines 9 and 10 Elevation Referenced to: ( ) NGVD ( ) MSL Soil Type 1 Structural Fill 2 Final Grading Fill 3 Mass Grading Fill 4 Utility Backfill - Sanitary 5 Utility Backfill - Water 6 UtilityBacktill - Storm 7 Roadway Subgrade 8 Stabilized Subgrade 9 Base Course 10 Other: Footing Excavation cc: (X) Other Inches below bottom of footing UCraig E. Dunkelberg FL Registration No. BUG 2 7 1/ 523A NW Enterprise Drive, Port St. Lucie, Florida 34986 • Phone: (561) 343-9787 • Fax: (561) State of Florida Board of Professional Engineers Authorization No. 6870 ��// D E &T DUNKELBERGER ENGINEERING & TESTING, INC. SOIL DENSITY TEST REPORT Project Name: New Manufacturing Building Report Date: 08-24-01 American Concrete Industries Facility Client Name: American Concrete Industries 350 N. Rock Road Project No.: 01-10-1053 Ft. Pierce, FL 34954 Date Tested: 08-09-01 Technician Initials: SM Attn: Mr. Bob Snowe Progress Report No.: 2 Sheet 4 of 6 Laborator r Proctor Field Tests Test No. Probe Depth in Maximum Dry Density c Optimum Moisture % Dry Density c Cone Resistance' is Moisture 0/U Minimum Required Compaction % Percent Maximum Density Test Result 1 12 110.7 12.4 112.8 - - - 10.2 95 100+ Pass 2 12 110.7 12A 112.2 - - - 7.2 95 100+ Pass 3 12 110.7 12.4 112.3 - - - 8.2 95 100+ Pass 4 12 110.7 12.4 110.3 -.- 8.4 95 99.6 Pass 5 12 110.7 12.4 --- 35+ --- 1 95 1 95 Pass 6 12 110.7 12.4 --- 35 --- 95 95 Pass Type of Field Density Test: ( X ) ASTM D 2922 ( ) ASTM D 2937 Minimum Required Compaction Based on: ( X ) AASHTO T-I80 (ASTM D 1557) ( ) AASHTO T-99 (ASTM D 698) 'Compaction percent estimated from cone penetrometer reading obtained with a Brainard-Kilman Model 5-214 hand-held cone penetrometer. Test No. Soil Type Elevation Test Location 1 1 0-12 Slab on grade, between lines A to B by I to 2 2 1 0-12 Slab on grade, between lines C to D by 4 to5 3 1 0-12 Slab on grade, between lines B to C by 8 to 9 4 1 0-12 Slab on grade, between lines C to D by 10 to 11 5 1 12-24 5' north and 10' east of southwest building comer RETEST of #1, 07-06-01 6 1 24-36 5' north and 10' east of southwest building comer RETEST of #2, 07-06-01 Elevation Referenced to: ( ) NGVD ( ) MSL Soil 1 Structural Fill 2 Final Grading Fill 3 Mass Grading Fill 4 Utility Backfill - Sanitary 5 Utility Backfill - Water 6 Utility Backfill - Storm 7 Roadway Subgrade 8 Stabilized Subgrade 9 Base Course 10 Other: cc: (X) Other Inches below top of final fill FL Registration A, Au � 523A NW Enterprise Drive, Port St. Lucie, Florida 34986 • Phone: (561) 343-9787 • Fax: (561) State of Florida Board of Professional Engineers Authorization No. 6870 - D E &T DUNKELBERGER ENGINEERING & TESTING, INC. SOIL DENSITY TEST REPORT Project Name: New Manufacturing Building Report Date: 08-24-01 American Concrete Industries Facility Client Name: American Concrete Industries 350 N. Rock Road Project No.: 01-10-1053 Ft. Pierce, FL 34954 Date Tested: 08-15-01 Technician Initials: SM Attn: Mr. Bob Snowe Progress Report No.: 2 Sheet 5 of 6 Laborator i Proctor Field Tests Test No. Probe Depth in Maximum Dry Density c Optimum Moisture % Dry Density c Cone Resistance' is Moisture % Minimum Required Compaction % Percent Maximum Density Test Result 1 12 110.7 12.4 111.5 --- 10.8 95 100+ Pass Type of Field Density Test: ( X ) ASTM D 2922 ( ) ASTM D 2937 Minimum Required Compaction Based on: ( X ) AASHTO T-I80 (ASTM D 1557) ( ) AASHTO T-99 (ASTM D 698) 'Compaction percent estimated from cone penetrometer reading obtained with a Brainard-Kilman Model S-214 hand-held cone penetrometer. Test No. I Soil Type Elevation Test Location 1 1 0-12 Slab on grade, 10' north and 25' east of southwest corner of slab Elevation Referenced to: ( ) NGVD ( ) MSL Soil Type 1 Structural Fill 2 Final Grading Fill 3 Mass Grading Fill 4 Utility Backtill - Sanitary 5 Utility Backtill - Water 6 Utility Backfill - Storm 7 Roadway Subgrade 8 Stabilized Subgrade 9 Base Course 10 Other: cc: (X) Other Inches below top of final fill Craig E. Dunkelbe q, P.E. FL Registration o. 9932 523A NW Enterprise Drive, Port St. Lucie, Florida 34986 • Phone: (561) 343-9787 • Fax: State of Florida Board of Professional Engineers Authorization No. 6870 �JUILD1A1& f'tPNIT A16. 2-105o39�JUL, 2 0 NOT J•`. , D E &T DUNKELBERGER ENGINEERING & TESTING, INC. SOIL DE Project Name: New Manufacturing Building Report Date: 07-13-01 American Concrete -Industries Facili Client Name: �merican-Concrete-Industries es JUL 2 3 2001 350 N. Rock Road Project No.: 01-10-1053 Ft. Pierce, FL 34954 Date Tested: 07-06-01 Attn: Mr. Bob Snowe St. Lucie County Pu hnician Initials: RM ess Report No.: 1 A (Sheet 1 of 3) Laborator Proctor Field Tests Test No. Probe Depth in Maximum Dry Density c Optimum Moisture % Dry Density c Cone Resistance' is Moisture % Minimum Required Compaction % Percent Maximum Density Test Result 1 2 3 4 5 6 12 12 12 12 12 12 110.7 110.7 110.7 110.7 1 110.7 110.7 12.4 12.4 12.4 12.4 12.4 12.4 107.5 1 110.1 111.6 40+ - - - --- 40 40+ 7.5 8.9 6.6 --- 95 95 95 95 95 95 97.1 95+ 99.4 100+ 95 95 Pass Pass Pass Pass Pass Pass Type of Field Density Test: ( X ) ASTM D 2922 ( ) ASTM D 2937 Minimum Required Compaction Based on: (X) AASHTO T-I80 (ASTM D 1557) ( ) AASHTO T-99 (ASTM D 698) Compaction percent estimated from cone penetrometer reading obtained with a Brainard-Kilman Model S-214 hand-held cone penetrometer. Test No: Soil Tvne Elevation Test Location 1 1 0-12 10' north and 10' west of southern -most southeast building corner 2 1 24-36 10' north and 10' west of southern -most southeast building comer 3 1 0-12 5north and 10' east of southwest building corner 4 11 0-12 At northwest building corner 5 1 12-24 At northwest buildingcomer 6 1 24-36 At northwest building comer Elevation Referenced to: () NGVD () MSL Soil Type 1 Structural Fill 2 Final Grading Fill 3 Mass Grading Fill 4 Utility Backfill - Sanitary 5 Utility Backfll - Water 6 Utility Backfill - Storm 7 Roadway Subgrade 8 Stabilized Subgrade 9 Base Course 10 Other: (X) Other Inches below top of fill cc: Client ... (1) R. K. Davis Construction Corp ... (1) (Attu: Mr. Roger Priest) 523AINW Enterprise Drive, Port St. Lucie, Florida 34986 • Phone: (561) 343-9787 • Fax: (561) 343-9404 State of Florida Board of Professional Engineers Authorization No. 6870 i D E &T DUNKELBERGER ENGINEERING & TESTING, INC. \ SOIL DENSITY TEST REPORT Project Name: New Manufacturing Building Report Date: 07-13-01 American Concrete Industries Facility Client Name: American Concrete Industries 350 N. Rock Road Project No.: 01-10-1053 Ft. Pierce, FL 34954 Date Tested: 07-06-01 Technician Initials: RM/KM i' r Laborator r Proctor Field Tests Test No. Probe Depth in Maximum Dry Density c Optimum Moisture % Dry Density c Cone Resistance' is Moisture % Minimum Required Compaction % Percent Maximum DensityResult Test 7 12 110.7 12.4 105.5 - - - 9.1 95 95.3 Pass 8 12 110.7 12.4 --- 35 --- 95 95+ Pass 9 12 110.7 12.4 - - - 40 - - - 95 95+ Pass 10 12 110.7 12.4 112.6 --- 7.4 95 1 100+ Pass 11 12 110.7 12.4 --- 40 --- 95 95+ Pass 12 12 110.7 12.4 - - - 40 - - - 95 95+ Pass 13 12 110.7 12.4 111.5 7.6 95 100+ Pass 14 12 110.7 12.4 --- 35 --- 95 95+ Pass 15 12 110.7 12.4 - - - 40 - - - 95 95+ Pass Type of Field Density Test: ( X ) ASTM D 2922 ( ) ASTM D 2937 Minimum Required Compaction Based on: ( X ) AASHTO T-180 (ASTM D 1557) (' ) AASHTO T-99 (ASTM D 698) 'Compaction percent estimated from cone penetrometer reading obtained with a Brainard-Kilman Model 5-214 hand-held cone penetrometer. Test No. Soil Type Elevation Test Location 7 1 0-12 100' east and 25' south of northwest building corner 8 1 12-24 1 00'east and 25' south of northwest building corner 9 1 24-36 1 00'east and 25' south of northwest building corner 10 1 0-12 10' west and 5' south of northeast building corner I 1 1 12-24 10' west and 5' south of northeast building corner 12 1 24-36 10' west and 5' south of northeast building comer 13 1 0-12 20' west and 10' north of southeast building comer 14 1 I2-24 20' west and 10' north of southeast building comer 15 1 24-36 20' west and 10' north of southeast building comer Elevation Referenced to: ( ) NGVD ( ) MSL Soil Type 1 Structural Fill 2 Final Grading Fill 3 Mass Grading Fill 4 Utility Backfill - Sanitary 5 Utility Backfill - Water 6 Utility Backfill - Storm 7 Roadway Subgrade 8 Stabilized Subgrade 9 Base Course 10 Other: cc: (X) Other Inches below top of fill Craig E. Dunkel FL Registration i I523A NW Enterprise Drive, Port St. Lucie, Florida 34986 • Phone:. (561) 343-9787 • Fax �! (�5611) State of Florida Board of Professional Engineers Authorization No. 6870 DRY UNIT WEIGHT POUNDS PER CUBIC FOOT 8 10 12 14 16 18 WATER CONTENT --- PERCENT OF DRY WEIGHT Sample Location: In -place pad fill Sample Description: Light brown medium to fine SAND, trace silt mixed with clayey sand (-200: 6.5%) 1ESULTS T-180 110.7 12.4 Sp -SC 3424 ly inv[o• UAm - "ZiVaII l K&L g11Uiv'Y"jP New Manufacturing Building American Concrete Industries Facility St. Lucie County, Florida UUNKELBERGER ENGINEERING& TESTING, INC. DET Cwkchniwl•Mueriak TaanQaorpeeaon•Environmwtal Tested By: KM Date: 07-05-01 Project: 01-10-1053 Checked By: CD Date: 07-13-01 Sheet: P.R. IA (Sheet 3 of 3; 1053dt32 1 ST LUCIE COUNTY FIRE DISTRICT BUREAU OF FIRE PREVENTION PLAN REVIEW 2400 Rhode Island Avenue Telephone: 561-462-2312 �Ft Pierce, FL 34950 FAX: 561462-2323 (M<ew Improvement ( )Addition ( )Renovation/alterations ( )Shell Only Construction ( )Tenant Jurisdiction: SLC F.P:B.: B-01-133 Occupancy: American Concrete Building Dept: 21050394 Address: 350 N. Rock Rd Number of stories: 1 Contractor RK-Davis Construction Phone# 561-461-8335 Contractor's Address: PO Box 186 City: Ft. Pierce Architect/Engineer: ML Engineering Phone # 561-569-1257 Building Owner. Review Date: 6/28/2001 Occupancy Type: Industrial Automatic sprinklers: Gross sq ft: /6000 Net sq ft: Occupant Load: Based On: Construction Type: SBCCI Type: IV unp • NOTE 1. All revisions must be in compliance before the final inspection. 2. The Fire Marshal requires 24 hour notice on all inspections. 3. The respective Building Department shall schedule all final inspections through the Fire Marshal's Office. 4. Permit fees are required to be paid in full prior to any inspections. 5. Failed inspections require payment of fee prior to rescheduling of further inspections. 6. A copy of the required revision/s have been transmitted to the Architect () Contractor ( ). 7. Penetrations through rated assemblies shall be of proper UL design. 8. UL design criteria shall be submitted with the construction plans. REVISIONS REQUIRED KNOX BOX IS REQUIRED( ) KNOX KEY SWITCH REQUIRED ( ) 1. Provide portable fire protection throughout. Reviewed by: Date: 6/28/2001 -'4 � 1 ST. LUCIE COUNTY CHECKLIST SUMMARY L*21050394*PLAN.BL BUILDING DIVISION CHECKLIST STATUS DATE OP ID DESCRIPTION / COMMENTS NO 06/12/01 BLD32 3. Building Department Review Complete COMMENT 6/12/01 l.fire dept review at completion of plan review. 2.electrical review at completion of plan review. 3.energy calc's reqd. 4.bathroom partition detail reqd. fire blocking reqd. 5.door sched. with sizes reqd. doors must comply w/ sbc 1012.1.2 and 1022.3 6.anchor bolt must be specified with embedment specified. 7.Anthony Lue must provide shop drawing review and approval of butler building dwgs as a/e of record. 8. plumbing dwgs reqd. 9. florida accessibility code details reqd. restroom turning circle must also comply with 4.23. Accessible route, parking etc. 10.Letterfrom owner reqd re:occupant content per shift. ll.hvac dwgs and specifications reqd. if applicable. 0 0, I G , \J qq of - RECOMMENDED PROCEDURES TO FOLLOW TO USE THE STANDARD BUILDING CODE 1. Determine Occupancj' / Classification of the structure. Select occupancy classification which most accurately fits the use of the building. (Chapter 3) 2. Determine actual physical properties of building. (a) Determine building area each floor. (Area definition Chapter 2) 1 (b) Determine grade elevation for building. (Grade definition Chapter 2) t (c) Determine building height in feet above grade. (Height definition Chapter 2) 2- `� • S (d) Determine building height in stories. (Story definition Chapter 2) 1 (e) Determine separation distance from exterior walls to assumed and common property lines. (Property line definition Chapter 2) k-( ( 1 (f) Determine percent of exterior openings per floor. 3. Determine minimum Type of Construction necessary to accommodate proposed structure Chapter 6) s-L,t . (a) Determine maximum allowable heights and floor areas for Types of Construction and Occupancy classification. (Table 500) S5 t t S pocp M (b) Check allowable height and area increases permitted. (Chapter 5) 4. Check detailed Occupancy requirements. (Chapter 4) 5. Check detailed Construction requirements. (a) Fire Protection of Structural Members (Chapter 6 and Table 600) / (b) Fire Protection Requirements (Chapter 7 and Table 705.1.2) (c) Means of Egress Requirements (Chapter 10) (d) Special restrictions if in Fire District. (Appendix F. The provisions of Appendix F are applicable only where specifically adopted by ordinance.) 6. Review design as related to standards. (Chapters 16-26) 7. Check other requirements as necessary. (a) Construction projecting into public property (Chapter 32) (b) Elevators and conveying systems (Chapter 30) (c) Sprinklers, standpipes and alarm systems (Chapter 9) (d) Use of combustible materials on the interior (Chapter 8) (e) Roofs and roof structures (Chapter 15) (f) Light, ventilation and sanitation (Chapter 12) (g) Other These steps are naturally varied in sequence by individual preferences; however, the first three are standard steps which should be followed in proper order to assist in design or review of buildings. SI V 4ty0 O 104' STANDARD BUILDING CODE* 1997 vll BOARD OF COUNTY COMMISSIONERS JL�E BOG PUBLIC WORKS • �" • DEPARTMENT �ORI�P TRANSMISSION COVER FORM Fax # (561)462-1148 IDATE: �'-11Z117S IFAX#:�k-q(�5-7CnCS COMPANY/DEPARTMENT: ' J RE: 2. 0 5 3 g y A MjgVL . co Y e F NUMBER OF PAGES SENT (INCLUDING COVER): 7/ SENDER: (� Y PHONE: S% (G 7— — 21 LS (K) For Your Information ( ) Original Will Follow in Mail ( ) Per Your Request COMMENTS: SPECIAL INSTRUCTIONS• ����� 3 ' o o 51;.- (XJ Take Appropriate Action 10 ( ) Please Call on This % � tti ( ) Please respond aG �l ASAP ( ) RUSH -1N D. BRUHN, District No. 1 • DOUG COWARD, District No. 2 • PAULA A. LEWIS, District No. 3 • FRANNIE HUTCHINSON, District No. 4 • CLIFF BARNES, District No. 5 County Administrator - Douglas M. Anderson 2300 Virginia Avenue • Fr. Pierce, FL 34982 Public Works: (561) 462-1485 • FAX (561) 462-2362 DivJ n of Engineering: (561) 462-1707 Fax 462-2362 • Division of Rood G Bridge: (561) 462-2511 FAX 462-2363 Division of Solid Wasre: (561) 462-1768 FAX 462-6987 • TDD (561) 462-1428 TRANSMISSION VERIFICATION REPORT 4 TIME : 06/12/2001 10:03 DATE,TIME 06/12 10:02 FAX NO./NAME 815614657665 DURATION 00:00:34 PAGE(S) 02 RESULT OK MODE STANDARD ECM R w n,. RM CORPORATION June 21, 2001 Mr. Geoffrey Vanore Plans Examiner St. Lucie County Building Dept. 2300 Virginia Avenue Fort Pierce, Florida 34982 Re: American Concrete Industries Bldg. Permit No. 21050394 Dear Mr. Vanore: CO 0013084 • P.D. BOX 186 • FT. PIERCE, FLORIDA 34864 :vj'*Q The following is in response to your plans review comments of June 12, 2001 for the above referenced permit application: Item #1: Fire department review at completion of plan review. No response necessary. Item #2: Electrical review at completion of plan review. No response necessary. Item #3: Energy calc's reqd. This warehouse building is not air conditioned or heated It is insulated to reduce the noise of rain and heat gain. An energy cale. is not required Item #4: Bathroom partition detail reqd. fire blocking reqd. A blow up restroom floor plan is now shown on page WA-2 along with a wall construction detail for this space - Item #5: Door sched. with sizes reqd. doors must comply w/ she 1012.1.2 and 1022.3. A door schedule has been added to page WA-l. Item #6: anchor bolt must be specified with embedment specified. An anchor bolt schedule has been added to page WS-l. Item #7: Anthony Lue must provide shop drawing review and approval of butler building dwgs. As a/c of record. Approve Butler shop drawings are provided Item #8: Plumbing dwgs reqd. A plumbing riser diagram has been included on page WA-2. Item #9: Florida accessibility code details reqd. restroom turning circle must also comply with 4.23. Accessible rout, parking etc. Handicap restroom details have been corrected and shown on page WA-2. The turning circle within the restroom has been correctly shown. All dimensions of the restrooms are now shown. A paved driveway will access this building from the main parking lot A concrete 301 MARTIN 68T. LUCIE 681-481-8338 • INDIAN RIVER 801-778-0188 • FAX 801-488-7685 • WWW.RKDAVIS.COM - KE> sidewalk will connect the personnel door beside the handicap restrooms to the paved driveway. ~ Item # 10: Letter from owner read. re: occupant content per shift. Letter from the owner is attached Item #11: HVAC dwgs and specifications regd. if applicable. This warehouse building is not heated or air conditioned, thus RVAC drawings should not be required Thank you for your comments. Please call should you have any further concerns we need to address. Sine ely, g A. Priest roject Manager ~ . �-W12/2001 10:02 5614621148 STLUCIECOUNT PAGE 02/02 ST. LUCIE COUNTY CHECKLIST SUMMARY L*21050394*PLAN.BL BUILDING DIVISION CHECKLIST ST}LTUS DATE OP ID DESCRIPTION / COMMENTS NO 06/12/01 BLD32 3. Building Department Review Complete COMMENT 6/12/01 l.fire dept review at completion of plan review. 2.electrical review at completion of plan review. 3.energy calc's reqd. ".bathroom partition detail reqd. fire blocking reqd. iS.door ached. with sizes reqd. doors must comply w/ sbc 1012.1.2 and 1022.3 v6.anchor bolt must be specified with embedment specified. 7.Anthony Lue must provide shop drawing review and approval of butler building dwgs as a/e of record. v� plumbing dwgs reqd. �9. florida accessibility code details reqd. restroom turning circle must also comply with 4.23. Accessible m�ute, parking etc. ilO.Letterfrom owner reqd re:occupant content per shaft. 11.hvac dwgs and specifications reqd. if applicable. Ks AMERICAN CONCRETE MU5TR1ESI INC. 350 NORTH ROCK ROAD FORT PIERCE, FLORIDA 34945 (561) 464-1187 • FOX (561) 595-9050 Y June 14, 2001 W Geoffrey Vanore Plans Examiner St Lucie County Building Department 2300 Virginia Avenue Fort Pierce, Florida RE: American Concrete Dear Sir: There will be six to eight employees working one shift in the new warehouse. Sincerely. IRobertL. Snowe President a RLS/maj e ��� ` Thi for I a wal the ST. LUCIE COUI.. 7 DEPARTMENT OF COMMUNITY DEVELOPMENT 2300 VIRGINIA AVENUE FT. PIERCE, FL. 34982-5652 561-462-1553 DESIGN CERTIFICATION FOR WIND LOAD COMPLIANCE CLertification is to be completed by the project design architect or engineer. This Certification must be submitted with all applications Aiding permit involving the construction of new residence (single or multRamily), residential addition, any accessory structure requiring ilding permit, and any nonresidential structure. This Certification shall not apply to interior renovations (provided that no structural columns or other similarcomponent is being effected) and certain other minor building permits. For further assistance, please contact luilding Inspection Office at 462-1553 or 462-2172: NAME O I PERMITNUMBER x- F(EP1.F . Ft- 3 4 9 4-7 --<V >W ��-�pE Mu ti$EnV— CERTIFICATION STATEMENT: vAczlO�' vvy 04ysyE I CERTIFY THAT, TO THE BEST OF MY KNOWLEDGE AND BELIEF, THESE PLANS AND SPECIFICATIONS HAVE BEEN DESIGNED TO COMPLY WITH THE APPLICABLE STRUCTURAL PORTION OF THE BUILDING CODES CURRENTLY ADOPTED AND ENFORCED BY ST. LUCIE COUNTY. I ALSO CERTIFY THAT STRUCTURAL ELEMENTS DEPICTED ON THESE PLANS PROVIDE ADEQUATE RESISTANCE TO THE WIND LOADS AND FORCES SPECIFIED BY CURRENT CODE PROVISIONS. DESIGN PARAMETERS AND ASSUMPTIONS USED: (please checkthe approprite box) 1. STANDARD BUILDING CODE 1997 EDITION ASCE 7-95 _ OTHER (SPECIFY) 2. BUILDING DESIGN IS (CHECK ONE) ENCLOSED PARTIALLY ENCLOSED _ OPEN BUILDING 3. BUILDING HEIGHT:_ FT 4. WIND SPEED USED IN BUILDING DESIGN: MPH 5. WIND EXPOSURE CLASSIFICATION (REFER TO EXPOSURE TABLES IN BUILDING CODE IDENTIFIED IN LINE 01): ♦U A 6. AVERAGE WIND VELOCITY PRESSURE ON EXTERIOR FACES OF STRUCTURE: Jr PSF PEAK WIND VELOCITY PRESSURE ON EXTERIOR FACES OF STRUCTURE: 45- PSF 8. IMPORTANCETUSE FACTOR (OBTAIN FROM BUILDING CODE): b o 9. LOADS: FLOOR AEO PSF ROOF/DEAD: b PSF ROOFA.IVE: 20//6//2-PSF 10. - -WERE SHEAR WALLS CONSIDERED FOR STRUCTURE (CHECK ONE) YES _ NO If NO, why? (attach explaination) l/PFtB—ENCIIN'VaiM/Wn MS'01— DI.Vlq W I•T•)} E>p ar V FftprvlEs) 11. I IS A CONTINUOUS LOAD PATH PROVIDED (CHECK ONE) YES ✓ NO _ If NO, why? (attach explaination) 12. I ARE COMPONENT AND CLADDING DETAILS PROVIDED (CHECK ONE) YES! NO _ If NO, why? (attach explaination) 13. I MINIMUM SOIL BEARING PRESSURE: �✓ Gb PSF -� \ AS WITNESSED BY MY SEAL, I HEREBY CERTIFY THAT THE INFORMATION INCLUDED WITH THIS CERTIFICATION IS TRUE AND CORRECT, TO THE BEST OF MY KNOWLEDGE AND BELIEF. ; NAME'. CERTIFICATION NO: DATE: 4152a I M: I N E51 [SEAL HERE] DESIG�i IRM L- �,,1G 4�w 1.l(� , • . I I SLCCDV FORD NO. 02GM I COMMERCIAL & MULTI FAMILY CHECKLIST + A yY Dale ( Reviewed By ��� Bldg No Permit No �-1 0 3 ' J AAA•.ss _�¢�a �` • � -2oc�,t� F •?Zc rc-gL, Project Name G,,m en • C's�t.► C.. I 9 C 3ctor owner'>v-1 - 1av� Occupancy V No of Occup i SQ Const Type Spk-\&,, Prot , -�SL L Sq Figs (see last page) C, L'2 HeighCz S" Stories l Units Miscellaneous 1. DATE OF APP ALS 5. k.Energy Code 9 P/Z LEng X 6. Notice of Com enc LRECD. Water X 7. Soil Tests: A�B . C D FIR ��� ellfield 8. Truss Layout: Manu DesgnrEng ? BCHD �t SFWMD> 9. Plans s/s by Lam 2 � L �� Hotel, Restaurant 10. Developer Agreement Other 11. Special Insp Form #1 #2 � 2. Application Com ei- 12. Value ) 3. Flood Dev Zone FF ft. 13. Designer Cert Form n 4. Survey Site Plan �Q 14. Spec Book 4' �a. DACS food establishment Info 15. IPS: Prod Appr Eng PR3.96 Check ifrequiiements of ALL appropriate sections are met. ti0� CHAPTER 3 OCCUPANCY TYPE Classification IF Subclassification CHAPTER 4 SPECIAL OCCUPANCY requirements met $ C Primary Occupancy Type (grandstand, automotive, etc). G� on Comments CHAPTERS HEIGHT AND AREA requirements met (Attach separate sheet for square footage breakdown, total and value of building.) 9F+ S �54� 503.2 Height Modifications: Roof Top Mezzanlne i� Basement OUnlimiled Helgltt 503.3 Area Modification Used: Sec Increase Amnl 504 Bldg on Same Lot /�- TABLE 500 Occupancy t ConstType Spk Prot_ Proposed: Sq Fig per Fir t O QD O Total Bldg .�"� 2 Height r Stories Allowed: Sq Fig per Fir l a J Total Bldg = 00d Height S s Stories Z Table 500 Notes Used Comments CHAPTER 6 CONSTRUCTION TYPES requirements met 1/ Proposed 609.2.4 Partition 610.1` Mxad Const Type %1�- (. __ _f Height Limits & 610.3 Open Prk Strclr / V V -L)E 600 REQUIRED FIRE RESISTANCE met 4111 Const Type � P/Unp _ Party/Fire Wall Nonbrg Wall_ hr Typ Sec hr Typ Section Bms, Gders, etc hr Typ Section Roof and Ceiling _ Exterior Bearing Wall Exterior Nonbrg Wall Design Ref Numbers. Notes Used �mehls CHAPTER 7 hr Typ Section hr Typ Section hr Typ Section Inl Brg Wall hr Typ Section Columns hr. Typ Section Floor/Ceiling hr' Typ Section % Openings % Openings RESISTANT MATERIALS AND CONSTRUCTION requirements met 701.3 Column Fite Resistance 701.5 Excepllons Used 1 Y 703 Materials for Fire Resistance r TABLE 704.1 OCCUPANCY SEPARATION REQUIREMENTS (List occupancy of each area) Occupancy Separation hr Occupancy � Separation hr Occupancy Separation hr Occupancy Separation hr 7 '.2 AccessoryOccupancy Section used for P Y 7 . .3 Special Occupancy Separation used for TABLE 704.1.4 HAZARD OCC P�SEPARATION�E ENTS () Occu _ H1 2 H3. H4 Excaption Sec s 704.2 Interior Wall, Partition Sec(s) for occup 704.3 Tenant Fire Separation 704.4 Townhouse 704.5 Fire Wall/Pi 705.1.1.3 Protection f Opening: Ext Wall �Exception Int Wall — Comments \ 705.1.3. Fire Window, Door, Shutter: Class Rated S 7^s 4112.2 Fire Dampers Comments T 705.1.3.E WIRE GLASS LIMIT: Class RatingMa i Comments TABLE 700 MINIMUM FIRE RESISTANCE Component Shaft Eric (stories Refuse Stride Fire Walls Inl Tenant Partitions Tenant Separation Horizontal Exit Exit Access Corridor Smoke Barriers OCCUPANCY SEPARTN Notes used 705.2.1.4 Fire 705.2.3 Shaft Eric C, tents 7 5.3.1 Fireblocking, , raftst TABLE 705.3.1.4 PENETRA 705.2.2 Shaft En .Exception # U, elf Closing x Area X Max 705.1.5 Stairway Enclo, Component ; Refuse,Lndry Chute Access Incinerator Rooms Refuse;Lndry Chute End Hazardous Occup Clrl Area High Rise Buildings Covered Mall Buildings Assembly Buildings Bathrooms, Restrooms Exterior Walls Exception # Used 705.2.4 RefuselLndry Chute Y Conduit, Pipe, Tube Location N h Dudis Location C h Fclry Bit Vent, Chimney Location C N Cables, Wires Location C N _ A 705.4 PENETRATION OF IR - RESISTAN A MBLIES 705.4.3 Walls, Shaft Enc Method 705.4.4 Floor, Roof, CellingMelhod TABLE 705.4.4 PENETRATION PROTECTION OF FIRE RESISTANT -ASSEMBLY Conduit, Pipe Tube Location Ducts Location Fctry Bit Vent, Chimney Location Cables, Wires Location 706 Combustible In Fire Rated Assembly 707 in G 709 Calculated Fire Resistance req'mnts met for F rs Columns Beams C TER 8 INTERIOR FINISHES requirements met C '-,B _Method C /N N _ 707.2 in Plenums Walls Width r used 2 .y �r,Cxn_ �� Access /\ Other 6 Floor FiOish'— 803.8 Inl Finish T--Comment IAPTER 9 FIRE PROTECTION SYSTEMS requirements met V-Q J 13 Sprinklers Req'd per Sec(s) for Occupancy 04 Standpipe 905.1 Manual Fire Alarm 905.2 Auto Fire Detection omments • 'CHAPTER 10 MEANS OF EGRESS requirements met TABLE 1003.1 MINIMUM OCCUPANT LOAD (Write on floor plan the occupant load of each area) Primary Use V-7 Area SgFt�OC' 00 er Occup Q 0 = IS O 1003.2 Measuremnt M of E - 3 <<2� ZF opacity M of E 1004.1 Exit Number, Arran�t.�a TABLE 1004 TRAVEL.. CD END, EXIT, MEANS OF EGRESS Occup MaxT@f'� 6°'� dEnd Egress Width Corridor Clear Opening Stair UnsR yt��''. �1yd orrldor Level Stair or Aisle Exit Doors a� by 3 � •O� / Noe �y d nde`c(o ents TA LB E 1004.11sed 1004.2 Minimum # of Exits (check each area) 1004.3 Access'ble of E 1004.3.5 Areas of Refuge Comment SPECIAL EXIT REQMNT 1005.1 Boiler, etc 1005.2 Dead -End 1005.3 Exit Acc Corridor �t Coments 1005.4 Emer Egress Opng 1005.5 Smo4prr Enc 1005.6 Mezz Exits req'd _%� TABLE 1 STAIRWAY PROTECTION 100 .1 Eric osed Stair_ 1006.2 Exl Exit Stair Co STAIRWAY CONSTRUCTIO�Nf Typical Section 1007.1 General 1007.5 Handrail 1007.8 Special Stair Type 1009 Horizontal Exits 1011 Fire Escape Garage Door Sizes —y 1013 Ramp 1015 Guardrail EXIT REQUIREMENT BY 1019 Assembly 1020 Business 1005.6.3 Egress 1005.7 Burglar ar Exception # 1007.3 Treads, Risers iL 1007.4 Landing 1007.6 Width 1007.7 Headroom Y 1008 Access to reef 1012 Door At Discharge / \ oor Schedule cy�2 Anchoring 1014 Balcony, etc \ W r-�0 7> Guardrail Detail 1016 Exit Sign (for primary and secondary occupancies) Seating Layout_ x 1021 Education+ 1022 Factory -Industrial 1023 Hazardous 1024 Institutional 1025 Merchantil 1026 Residential 1027 Storage_ CHAPTER 11 ACCESSIBILITY (see Florid Accessiblity Code) CHAPTER 12 INTERIOR ENVIRO NT reuuirements met 1203 Light, Ventilation 1204 Sanitation 1205 Rodent Proof CHAPTER 13 ENERGY CONSERVATION (See Florida Model Energy CHAPTER 14 EXTERIOR WALL COVERING requirements met e 1403.2 Masonry Vane 1403.5 Glass Veneer 1403.8 Stucco 1404 Trim, Balcony, etc 403.4 Metal Veneer 1405 F/D Access In Ext Wall Comments_ CHAPTER 15 ROOF AND ROOF STRUCTURES requirements met 1503 Penthouse Type 1504 Tanks 1505 Cooling Tower 1506 Other 1507 Parapet Wall 1508 Gutter/Leader 1509 Roof Covering Requirements met Type of Roof Code Section Class Slope Underlayment Fastening Flashing Menu Specs CHAPTER 16 STRUCTURAL LOADS r Irements met 1603 Dead Load 1604 Live Load TABLE 1604.1 LIVE LOADS Occupancy X Live Loads Occupancy_ Live Load_ TABLE 1604.3 MIN CONCENTRATED LOAD TBL 1604.6 ROOF LIVE LOAD Slope 1604.7 Impact Loads 1606 Wind Load requirements t <60 ft high = 1606.2 1606.3 Roof Systems V \\ '' 1606.4_Imnaci Prnteclinn KAPOhnd 'X Load for = psf _ Trl Mary Area sf = 2— psf L.L 1604.8 Walkway Support Coastal Const Zone • it high = ASCE 7_ Xi TABLE 1606 Use Factor F— C i TABLE 1606.2A VELOCITY PRESSURE Height? c� n pee CHAPTER 17 STRUCTURAL TESTS AND INSPECTIONS requirements met --------_..._ — --I a Rt+l k I A \=> JT�L Vk--PCV". 1 5'5 e� e ,.a � v� gclJ S f CHAPTER 18 FOUNDATIONS AND f�TAI ING WALLS requlreme0ks met tr �. � r � n_ 1804.4 Ftg Design -Type \ /Size Bars ✓ Lap TABLE 1804.6 Fdtn Wall Thickness Maxl um depth of FIII 1804.6.3 Crawl Space 04.2.7 Soil Tests _ CartIOcatlon/DensiIy 1805 PILE Type and Code Secll s 1605.1 Investigation Z T 1806.8 Spacing 1805.10 Caps C 1805.14 Location Minimum Sizes A Reinforcement Concrete Coverage 1814 Water/Dampproof Comments CHAPTER 19 CONCRETE rl' F Specifications__F Reinforcement U CHAPTER 20 LIGHT M CHAPTER 21 MASONf 2105 Shear Walls 2108.2 Parapet_ 2110 Anchorage 2113 Chimney Mortar/Grout 1908.6 Coverage Slab requirements met tj met _ ?` 2101.2 Specs 2108 Wall Thickness Waterstop _Column Detail Beam Detail 2111 Masonry Const 2112 Glass Block 2114 Fireplace/BBO CHAPTER 22 STEEL requirements met • • IAPTER 23 WOOD requirements met )1.7 Moisture, Grade )4.3 Crawl Space Wis: Exterior Interior D5 Fireblocking 2304.1.5 Soil Treatment 2304.5 Walls 2304.2.3 Clearance Rated Wall Design No 8, Detail 2305.2 Draftstopping Connectors Specified at: Bottom Top Roof Headers Beams Misc ,BLE 2306.1 (Addendum) FASTENING SCHEDULE 07 Floor Framing 2308 Vertical Framing orders (Tables 2308 2309 Roof, Ceiling Framing 09.6 Attic Access uss Manu Layout )mments Engineering 2309.7 Attic Vent Diaphragms 1APTER 24 GLASS AND GLAZING requirements met ichoring Specified 105.2 Hazardous Location 105.3.1 Vertical Table_ 07 Sloped Shop Drwgs Type Thickness Construction Detail Section 2405.3.2 Sloped Table _ 2405.5 Railings HAPTER 25 GYPSUM BOARD,'PLASTER requirements met Lathe Underlaymenl HAPTER 26 PLASTIC requirements met HAPTER 28 ELECTRICAL SYSTEMS requirements met _ HAPTER 28 MECHANICAL SYSTEMS requirements met 304 Chimney: Type Detail :uj-. B08 Barbecue MBING SYSTEMS requirements met Doors 2810 Fresh Air Intakes HAPTER 30 ELEVATORS AND CONVEYING SYSTEMS requirements met 003.1 Elevators Enclosure 3003.1.7 Construction 003.4 Stretcher Reqmnts 003.6 Vents :omments 3003.5 Standby Power 3003.7 Machine Room Access :HAPTER 31 SPECIAL CONSTRUCTION requirements met 104 Covered/Enclosed Walkways 3106 Exterior Wall Canopies ,401 Flood Plain Elevations 3108 Signs :NAPTER 32 CONSTRUCTION IN PUBLIC RIGHT OF WAY requirements met _- X\Jx 1204 Marquees, Canopies, Awnings 1206 Projections 3205 Roof Drainage 3207 Under Public P :HAPTER 33 SITE WORK, DEMOLITION, CONSTRUCTION F�nspectlId�44�G�~ CHAPTER 34 EXISTING BUILDINGS requirements met :$ ra: re Ely 3403 Assessibllity 3404 Grandstand, BleaclWj S. O Comments *IDA ACCi ESSIBILITY CODE FOR BUILDING CONS equirements met 4.1 Accessible Elements, Spaces 4.2 Space Allowance, R ach Range _ L�,23 ,ecesslbte Route / 4.4 ding Objects round, Floor Surface 4.6 Parking :urb Ramps 4. amps Rairs 4.9.4 Handrails �levalors 4.11 Platform Lifts J �oors Hardware 4.14 Entratt�e Fountain 4.16 Water Closet 4.17 Toilet Stall Urinal 4.19 Lavatory, Mirror 4. 0 Bath Shower c �e 4.22 Tm�Yet Room 3 Bathroom Sinks 4.25 Storage 4.26 Handrail, Grab Bar 4.28, 4.29, 4.30, 4.31, 4.34, 5.5 - 5.8 field checked. O b� b Seating 4.33 Assembly Area 4.35 Qrgs r rf�t o! testaurants, Assembly 6.0 Medical Care _ 7.0 Bye. a„^ .Ibrary 9.0 Transient Lodging _Jo TA o� , nls .r nb o IONAL ELECTRIC CODE 22 1996 requirements met 41 -gi O v , v— r� Meter Location Panel Location R13DIagram Ice Size Total Per Unit Recepticles n' 2 GFI mnecls Exit Lights Calculatlor y ty d Layout Smoke Detector a ant ter Location menls VDARD PLUMBING CODE requirements me .E 407 Facilities Required: ppanc 1— 4 `1 Male Persons Female Diagram Specs _ 'Load Cafes it ;e Hood, Duct System Water Closet Slab Layout rga.. MIR lulrements met SEER Mechanical Closet Duct Specs Duct Insulation Penetrations RATE PERMITS REQUIRED FOR: DRAWINGS REQUIRED FOR: Lavatories Miscellaneous Htr Locallori Type KW Attic Access _ Grill Size Misc 6 'w Y T i i C'E�tANEOUS f Mi _f • I