Loading...
HomeMy WebLinkAboutPERMIT WORKSHEETJ 5• R• ` .VERMIT NUMBER installer %�ioncay , C_ J n..vLicense 0 bA dress r home _37oS �n,,,t G7 / 7-.r7haWled LcrG/c FL. Manufacturer . I -Iakfe,/ Ummh x width 2Z 19 X 611 607M • ff home 1s a aktgle wide W1 out one half of the blooldng plan tthotge lsa triple or quad wide sketch in remaindercf home I understand Worst Arm Systems cannot be used on arty home (new or used) where the sldewall ties exceed 5 ft 4 In: c ' Instances rnhials QE yploW pier Spacing - LLI ti 56ow locations of Lon9bdinal and Lateral Systems U ® (use dark lines to show these locations) LULU m SCANNED r PERMIT WOFIKSHEET BY St. Lucie County page 0of 2 New Home . 1 �i] Used home ❑ Home installed to the Manufacturer's Installation Manua! [� . Homa Is Installed In acoordanos wlih Rule 16.0 ❑ MAID wide ❑ Wind Zone II Iff Wind Zone III ❑ Double wide ' [2 Installation Decal 8 Triple/Quad ' ❑ Sedal d PIER SPACING TABLE FOR ttaPn untuee Load Footer bwrkg sty qP5* (sq R) 1GxiC (z661 toVP'xiet/2, (34� ;'� : -: ----- •WxW (�)' Wxv (676)` . 2e xW (616) P 6a. g &1ntB=WM 6 PIER PAD S¢ES _A — -- I-beampier Pad size /7XZTXI Perimeter pier pad size Otherplerpadsbae ^��A (required by the mfg.) ®Omw the approximate locattons of maniage WWI openings 4 toot or greater. Use this symbol to show the plats• List all marriage wall open@igs greater than 4 foot and.lhelr pier pad sizes below. Opening ANCHORS Pier pad size (7,fKzf /7r?, 4It it ' FRAneEnes Within 2 of end of home Spaced at G 4' co ,_ TIEpOWN COMPONENTS OTHER ES Lonyhudlnal Stab! Manufacture i Aor" r `asr,, i�C � (j p Ntattber dewall S'y a Lon9SudlnalW1*b11Wng Device w/ feral Arms Manu(poturer_,MIAewaA rriaganPitudlnai - • `• ;CA BNY ED PERIIT WORKSHE PERMITNUMBkrt E� Lucie ...... . Cou my O The pboket m :frometertesta are rounded down to �DoO pet or check here•tb declare 10We Ib soil wifhota testktg X� X^ X_ POCKET PENETROMETER TESTING METHOD 1. Test the perimeter of the hoiho at 6 locations. 2. Take the reading at the depth of the fcoter. S. Using SOD lb, litoremetde, tape the lowest reading and round down to that Increment. 11.11 PROBE The results of the torque probe test Ir;< 29 D "pounds or check here ff you ere dedadng 5 andmre wdtitout tasting _mcA test showlitg 275 inch pounds or leas will require 5 foot eees Nato: A slate approved lateral arm system Is being used and 4 it. -anchors are allowQd at the sldewall locatlons6 I uddemiand a it anthers are required at all centerline tie pointy More the torque test reading Is 276or lase and where the mobile }tome manufacturer may requires anchors with 4000 Ib holding cup sa _ 7-4 Ins} see Inklais ALL TESTS MUST BE PERFORMED BY A LICENSED INSTALLIM Installer NamO Date Tested i Fc6 rf Zoy 9 enact electrical,conduotors between muiti-wide [mils, but not to the main power curse Thle•Ino luden the bonding wUe between muff -wide unts. Pg. _ d1D flurabina - enact all sewer dmkw to tin =Wing sewer tap oreeptic Tank Pg. 416 onneot all trolable; water supply piping to an sedating water meter, water tap, or other rdependegt water supply systems Pa._� page 2 of 2 . Site P aza an Debris and organic, material removed V- Waterdreinape IJatural SWala�_�Ped Other_ n murtl wl a units Roor. Type Fastener 3�1. Length: S� /i ' wv Wails: Type Fastener 71 Spacing Roof: Type Fastener. Length: S.5 spacintr �` ,� Leng{h:_ sAadn For.Ilsed homes a min So gaups, S' wld, , m�t� will be centered'over the peak o} the roof and fastened with gale. rooting mills at 2° on center an both sides of the contorting, -. Oedte �.�..-nm6vrr01 ••• I understand a propedy installed gasket le a requlrwn I o1 all n andaw used homes and that condensation, mold meldew and buooned marriage wells era a result of a poorly installed or no gasket being installed I understand a strip of tape will not naive as a gasket. Installer's Initials Type gasket �" r' trvL Installed: Pp. �—Ig_ Between Floors Yes Between Walls Yes �"-- Bottom of ridgabeam Yes v The bottomboard will be repaired and/or taped. Yes ✓ pg 2.93 — Siding on units is Installed to manufacturer's apeoHloetfona ea r✓ Fireplace chimney Installed so as not to allow intrusion of rain water etas ./% sous Skleflnn fn he lnclve W Vw._ '✓ u_ --....._._.�.. ...-.._.���......o... o...uu,N. ens ryrA � . es supported at 4 foot krtervals�s L/ _ I orossovers protected Yee ls: accurate and true based'on