HomeMy WebLinkAboutNOAcoullTr
SCgyNED
St Lucie Co
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Unty
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Sheet, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.miamidadc eov/economy
Owens Corning Roofing and Asphalt, LLC
One Owens Corning Parkway
Toledo, OH 43659 THESE PLANS AND ALL PROPOSED WORK
SCOPE: FILE C®'1 REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
This NOA is being issued under the applicable rules and regulations governing(Rf�EkY(W T &6&nPri18T0i1�6s ODES_
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Duration®, Duration® Premium, TruDefinition® Duration®, and TruDefinition® Duration®
Designer Colors Collection
1zVV,hfi"P"4o2-DI`f -
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manu
shall be available for inspection at the job site at the request of the Building Official. %W�W�tp"" ACHMENTS
RESPONSIBILITY OF THE
This NOA renews NOA No. 12-0309.01 and consists of pages I through 6. OR OR RECORD
The submitted documentation was reviewed by Gaspar J Rodriguez.
lob
Ids
V I
MIAM4DADE COUNTY
5 LUCIE COUNTY BUILD G DI
NOA No.: 16-0425.01
REVIEWED FOR C0 PLIANC
Expiration Date: 07/19/21
REVI�Approval
REVI Y
Date: 07/21/16
DAT
Page 1 of 6
PLANS AND PERMtr MUST BE KEPT JOB
SITE OR»»NO INSPECTION(S) WIL MADE
ROOFING ASSEMBLY APPROVAL
Category:
Roofing
Sub -Category:
Asphalt Shingles
Materials:
Laminate
Deck Type:
Wood
SCOPE -
This approves a roofing system using Owens Corning Duration® and Duration® Premium asphalt shingles
manufactured by Owens Corning as described in Section 2 of his Notice of Acceptance.
PRODUCT DESCRIPTION
Product Dimensions Test Specifications
Duration® 13 '/4" x 39 3/$ -
Manufacturing Locations #1, 2
Duration® Premium; 13 '/4" x 39 3/8"
TruDefinition® Duration®;
TruDefinition® Duration®
Designer Colors Collection
Manufacturing Location #1, 2, 3, 4
Duration® 13 %" x 39 3/e"
Manufacturing Location #1, 2, 3
Duration® Premium; 13 '/4" x 39 3/8"
TruDefinition® Duration®;
TruDefinition® Duration®
Designer Colors Collection
Manufacturing Location #1, 2, 3, 4
MANUFACTURING LOCATION
1. Jacksonville, FL
2. Memphis, TN
3. Savannah, GA
4. Irving, TX
Product Description
TAS 11 o A heavy weight, fiberglass reinforced
four tab asphalt shingle with
continuous bead of sealant.
TAS 110 A heavy weight, fiberglass reinforced
four tab asphalt shingle with large nail
area with continuous bead of sealant.
TAS 110 A heavy weight, fiberglass reinforced
four tab asphalt shingle with dashed
bead of sealant.
TAS 11 o A heavy weight, fiberglass reinforced
four tab asphalt shingle with dashed
bead of sealant.
MIAMMADECOUNTY NOA No.: 16-0425.01
Expiration Date: 07/19/21
Approval Date: 07/21/16
Page 2 of 6
EVIDENCE SUBMITTED
Test oency
Test I_ d_ e_ ntifier
Test Name/Reoort
PRI Asphalt Technologies, Inc.
�—
Date
OCF-157-02-01
OCF-102-02-01
TAS 100
10/26/10
OCF-156-02-01
TAS 100
TAS 100
11/12/07
OCF463=02-01
TAS-100
10/26/10
OCF-164-02-01
TAS 100
12/10/10
OCF-098-02-01
TAS 100
12/10/10
OCF-099-02-01
TAS 100
02/22/07
OCF-102-02-01
TAS 100
02/26/07
OCF-172-02-01
TAS 100
11/12/07
Underwriters Laboratories, Inc.
OCF-179-02-01
TAS 100
05/26/11
02/02/12
07CA39536
03NK04954
TAS 107
11/11/07
03NK04954
TAS 107
TAS 107
03/28/03
1ONK13947
TAS 107
/11/
1111/12/10
1ICA15662
TAS 107
05/27/11
11NB21712
TAS 107
02/18/12
07CA02026
ASTM D 3462
01 6/ /207
12CA12180
ASTM D 3462
0//07
LIMITATIONS
I. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61 G20-3 of the Florida Administrative Code.
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail 'A', attached.
5. Nailing shall be in compliance with Detail 'B', attached.
LABELING
L Shingles shall be labeled with the Miami -Dade Seal as seen below, or the wording "Miami -Dade County
Product Control Approved".
MIAMI•DADE COUNTY
MIAMIOADE COUNTY
NOA No.: 16-0425.01
Expiration Date: 07/19/21
Approval Date: 07/21/16
Page 3 of 6
Buu,DING PERMIT REQUIREMENTS
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
DETAIL A
MIAWDADE COUNWIE NOA No.:i46-0425.01
Expiration Date: 07/19/21
Approval Date: 07/21/16
Page 4 of 6
DETAIL B
DURATION & TRUDEFINITION® DURATION®
(SEALANT MAY 13E CONTINUOUS OR DASHED. NOT SHOWN IN THE DETAIL DRAWINGS)
D�
va
mz
a
a—
c g
�m
MAMMADE COUNTY NOA No.: 16-0425.01
Expiration Date: 07/19/21
Approval Date: 07/21/16
Page 5 of 6
a t`daii pattern
F-Sgwma do 6 cb ryas
b 51E" sure
S Str tit= expostci6n
s1l*F" 'a faslenEng we.2 width
Ara3 dodavas SuraWja
CL-Mvs
MAXIMUM SLOPE 21:12
S sm- Fxpowrw%
6 5/8" de eVosac56n
Fastening for Slopes Greater Than 21:12
SureNailO fastening area width
Nail, Typical
12" I F F, 12"
6.1f8" 5-5/8"
eiposme � - ,
Four V Spots of Asphalt Roofing Cement
SLOPE GREATER THAN 21:12
END OF THIS ACCEPTANCE
)l
MLAMFDADE COUNTY NOA No.: 16-0425.01
Expiration Date: 07/19/21
Approval Date: 07/21/16
Page 6 of 6
MIAMI•E�
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC R ES ) ^ qqq 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DMSIONo Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA)�i M 9 U ' W( www.miamidade.eov/economy
GAF FsTIL_4��Wlw"�,
ECEIV
1 Campus Drive SCANNED
Parsippany, NJ. 07054 EB 15 Z019
Sk Lucie unty
SCOPE: leCoamlCO
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Cobra® Exhaust Vent for Roof Ridge
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No. 14-1224.18 and consists of pages 1 through 3.
The submitted documentation was reviewed by Jorge L. Acebo.
NOA No. 18-0619.02
Expiration Date: 11/09/19
Approval Date: 11/15/18
Page 1 of 3
ROOFING COMPONENT APPROVAL
Category
Roofing
Sub -Category:
Ventilation
Materials:
Plastic
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
_ Test -Product
Product Dimensions Specification Description
GAF Cobra® Exhaust Vent 3/4" x 10 1/2" x 20' TAS-100 Low profile attic ridge vent for installation
for Roof Ridge under ridge shingles.
GAF Cobra® Exhaust Vent 5/8" x 10 1/2" x 20' TAS-100 Low profile attic ridge vent for installation
for Roof Ridge under ridge shingles.
(For nail guns)
EVIDENCE SUBMITTED:
1. Acworth, GA.
EVIDENCE SUBMITTED:
Test Agency/Identifier Name
Intertek - Architectural Testing TAS 100(A)
ASTM D 1929
ASTM D 635
ASTM D 2843
MIAMI-DADE COUNTY
F.W. 1
Report Date
I3223.01-109-18
06/06/18
13223.02-106-18 RI
07/20/18
13223.02-106-18 RI
07/20/18
I3223.02-106-18 Rl
07/20/18
NOA No. 18-0619.02
Expiration Date: 11/09/19
Approval Date: 11/15/18
Page 2 of 3
APPROVED APPLICATIONS
Tradename: GAF Cobra® Exhaust Vent for Roof Ridge
System Type: Mechanical attachment of static vent over asphalt shingle roof systems only.
Cutout: Cut a 2" slot along the ridge of the roof by cutting 1" on each side of the ridge. Leave uncut
sheathing area of 6" at each end of the ridge. Cut through sheathing only, avoiding roof trusses.
In buildings with a ridge board, cut 1-3/4" slot on each side.
Installation: Roll out ridge vent centered over the slot, and secured 6" o.c. on each side of the ridge with
included 2-1/2" corrosion resistant galvanized roofing nails or 1-3/4" collated corrosion resistant
galvanized roofing nails (for nail guns) to hold it in place until ridge shingles can be installed.
(Polyurethane sealant shall be used to seal the perimeter of the vent to the roof shingles.) Extend
to the rake edge. Roll ends or cut joints shall be butted together and caulked with an approved
polyurethane sealant.
Ridge Shingle: Install pre -manufactured or field -cut ridge shingles over the ridge vent in compliance with the
shingle manufacturer's Notice of Acceptance (NOA) and the installation instructions.
Ring shank nails shall be corrosion resistant and long enough to penetrate through the wood deck
a minimum of 3/16". Apply a bead of polyurethane sealant in between adjacent cap shingles to
seal the caps.
Net Free Area: Refer to manufacturers published literature.
LIMITATIONS:
1. Refer to applicable building codes for required ventilation.
2. This acceptance is for installations over asphalt shingle roof systems only.
3. GAF Cobra® Exhaust Vent for Roof Ridge shall not be installed on roof mean heights greater than 33 feet.
4. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
5. All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the
manufacturer's name or logo, city and state and following statement: "Miami -Dade County Product Control
Approved" or the Miami -Dade County Product Control Seal as shown below.
END OF THIS ACCEPTANCE
NOA No. 18-0619.02
Expiration Date: 11/09/19
Approval Date: 11/15/18
Page 3 of 3
MIAMI = �S NNEC
mom St.I BY
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) LuC1e COUnty
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA) RECEIVED
CertainTeed CR555
20 Moores RoaMalvern, PA 1
&T.
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786)315-2590 F (786) 31525-99
w "v.miamidade.eov/economy
FEB I5 2019
SCOPE: ----�
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: CertainTeed Modified Bitumen Roofing Systems over Wood Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No. 17-1003.04 and consists of pages 1 through 49.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 18-1127.18
Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 1 of 49
ROOFING SYSTEM APPROVAL
Category'
Roofing
Sub -Category:
Modified Bitumen
Material:
APP/SBS
Deck Type:
Wood
Maximum Design Pressure:
-127.5 psf.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Sheet
Flexiglas Base Sheet
Roll weight: 70 lbs.
(2 squares)
39 3/8" x 98'9'; Roll
weight: 90 lbs.
(3 squares)
Test Product
II base sheet.
ASTM D 4601, Type Modified Bitumen coated fiberglass
II base sheet.
Flintlastic Base 20 39 3/8' x 49' 6' ; Roll ASTM D 6163, Modified Bitumen coated fiberglass
weight: 901bs. Grade S, Type I base sheet.
(1.5 squares)
int as y 4'3 '.r 39 3{$" x 164'7 $oll ASTM D 2178 �yp�. Fiber lass as halt im re ated plp,shee
weight: 381bs. IV
(5 squares) UL Type Gl
Flintglas Premium Ply 6
eFlintlastic STA
Flintlastic GTA
39 3/s" x 164'7'; Roll
weight: 40 lbs.
(5 squares)
39 3/sn x 32' 10' ; Roll
weight: 87 lbs.
(1 square)
39 3/8" x 32' 10'; Roll
weight: 105 lbs.
(1 square)
ASTM D 2178, Type Fiberglass, asphalt impregnated ply
VI
sheet.
UL Type GI
ASTM D 6222,
Smooth surfaced APP Modified
Grade S, Type I
Bitumen membrane with non -woven
polyester mat reinforcement for torch
application.
ASTM D 6222,
Granule surfaced APP Modified
Grade G, Type I
Bitumen membrane with non -woven
polyester mat reinforcement for torch
application.
Flintlastic GTA-FR 39 3/8' x 32' 10' ; Roll ASTM D 6222, Granule surfaced APP Modified
weight: 105 lbs. Grade G, Type I Bitumen membrane with non -woven
(1 square) polyester mat reinforcement for torch
application.
NOA No.: 18-1127.18
Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 2 of 49
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test
Product
Product
Dimensions
Specification
Description
Flintlastic FR-P
39'/8" x 32' 10"; Roll
ASTM D 6164,
Fire resistant, granule surfaced SBS
weight: 101 lbs.
Grade G, Type I
Modified Bitumen Membrane with
-
- —(I-square) --
— -
- non -woven -polyester mat
reinforcement for mop application.
Flintlastic Premium FR-P
39'/8" x 32' 10'; Roll
ASTM D 6164,
Fire resistant, granule surfaced SBS
weight: 101 lbs.
Grade G, Type H
Modified Bitumen Membrane with
(1 square)
non -woven polyester mat
reinforcement for mop application.
Flintlastic FR Dual Cap
39'/8" x 32' 10' ; Roll
ASTM D 6162,
Granule surfaced SBS modified
weight: 103 lbs.
Grade G, Type II
bitumen membrane with a nonwoven
(1 square)
polyester/fiberglass composite mat
reinforcement for use in cold or mop
applications.
Flintlastic Cap 30
39 3/8' x 32' 10' ; Roll
ASTM D 6163,
Granule surfaced SBS Modified
weight: 86 lbs.
Grade G, Type I
Bitumen membrane with fiberglass mat
(I square)
reinforcement for mop applications.
Flintlastic FR Cap 30
39 3/8' x 32' 10'; Roll
ASTM D 6163,
Fire resistant, granule surfaced SBS
weight: 86 lbs.
Grade G, Type I
Modified Bitumen membrane with
(1 square)
fiberglass mat reinforcement for mop
applications.
Flintlastic FR Cap 30 T
39-3/8" x 32' 10"; Roll
ASTM D 6163,
Granule surfaced SBS Modified
weight: 100 lbs.
Grade G, Type I
Bitumen membrane with fiberglass
(1 square)
mat reinforcement for torch
application.
Flintlastic Base 20 T
39-3/8" x 33'; Roll
ASTM D 6163,
Modified Bitumen, coated fiberglass
Weight: 81 lbs.
Grade S, Type I
base sheet for torch application.
(1 square)
Flintlastic Ultra Poly SMS
39'/a" x 32' 10'; Roll
ASTM D 6164,
Smooth surfaced SBS Modified
Base Sheet
weight: 90 lbs. (1
Grade S, Type I
Bitumen Membrane with non -woven
squares)
polyester mat reinforcement for mop or
torched applications.
Glasbase Base Sheet
36" x 98' 9'; Roll
ASTM D 4601, Type Asphalt coated, fiberglass base sheet.
weight: 75 lbs.
II
(3 squares)
Flintlastic Poly SMS Base
39'/8" x 64' 3' ; Roll
ASTM D 4601,
Modified Bitumen coated polyester
Sheet
weight: 90 lbs.
Grade S, Type II
base sheet.
(2 squares)
NOA No.: 18-1127.18
Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 3 of 49
i
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test Product
Product Dimensions Specification Description
Yosemite Venting Base Sheet 39 3/8" x 32' 10'; Roll ASTM D 3909 Mineral Surfaced fiberglass reinforced
weight: 85 tbs. ASTM D 4897, Type buffer sheet.
Flintlastic APP Base T 39 3/s" x 65' 4'; Roll
weight: 1001bs.
(2 squares)
Flintlastic Ultra Glass SA 39 3/8" x 33' 11' ; Roll
weight: 73 tbs.
(1 square)
Black DiamondTM Base Sheet 36" x 68'7' ; Roll
weight: 78 lbs.
(2 squares)
Flintlastic SA P1yBase 39 3/8" x 66'6"; Roll
weight: 861bs.
(2 squares)
Flintlastic SA Mid Ply
F1intBond Brush
39 3/8" x 32' 1";
Roll weight: 621bs.
(1 square)
5 gallon pails
UL Type G3
ASTM D 6509 Modified Bitumen coated fiberglass
base sheet.
ASTM D 1970 Self -adhering, fiberglass reinforced,
SBS modified bitumen base/ply sheet.
ASTM D 1970 Self -adhering fiberglass reinforced
ASTM D4601 Type I modified bitumen base sheet
ASTM D 4601, Self -adhering, fiberglass reinforced,
Grade S, Type ll I SBS modified bitumen base/ply sheet.
ASTM D 1970
ASTM D 6163, Self -adhering, polyester reinforced,
Grade S, Type 1 SBS modified bitumen ply sheet.
ASTM D 3019 Cold applied, SBS polymer modified
asphalt adhesive.
NOA No.: 18-1127.18
Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 4 of 49
1
APPROVED INSULATIONS:
Product Name .
TABLE2
Product Description
FlintBoard ISO
Polyisocyanurate foam insulation
FlintBoardx ISO
Polyisocyanurate foam insulation_
F1intBoard ISO Cold
Polyisocyanurate foam insulation
ACFoam-II
Polyisocyanurate foam insulation
ACFoam-III
Polyisocyanurate foam insulation
DensDeck
Water resistant gypsum board
DensDeck Prime
Water resistant gypsum board
H-Shield Polyisocyanurate foam insulation
ENRGY 3 Polyisocyanurate foam insulation
ENRGY 3 25 PSI Polyisocyanurate foam insulation
Multi -Max FA-3 Polyisocyanurate foam insulation
SECUROCK Gypsum -Fiber Roof Board homogenous fiber reinforced
Structodek High Density Fiberboard High Density Wood Fiber Insulation
Roof Insulation board
FescoBoard
Expanded perlite and fiber insulation
Manufacturer
(With Current NON)
CertainTeed Corp.
CertainTeed Corp._
CertainTeed Corp.
Atlas Roofing Corp.
Atlas Roofing Corp.
Georgia Pacific Gypsum LLC
Georgia Pacific Gypsum LLC
Hunter Panels LLC
Johns Manville Corp.
Johns Manville Corp.
RMax Operating, LLC
USG Corp.
Blue Ridge Fiberboard, Inc.
Johns Manville Corp.
NOA No.: 18-1127.18
Expiration Date: 06/1923
Approval Date: 01/17/19
Page 5 of 49
APPROVED FASTENERS/ADHESIVES:
Fastener Product
Number Name
1. Trufast #12 DP Fastener
2. Trufast 3" Metal
Insulation Plate
3. F1intFast 912
4. FlintFast 3" Insulation
Plate
5. F1intFast #14
6.
7.
8.
9.
10.
11.
12.
13.
14.
Simplex MAXX Cap
#12 Standard Roofgrip
OMG 3" Galvalume Steel
Plate
Trufast #14 HD Fastener
OMG Heavy Duty
3 in. Round Metal Plate
AccuTrac Hextra
AccuTrac Plate
AccuTrac Flat Bottom
Plate
Millennium One Step
Foamable Adhesive
Millennium One Step
Green Foamable Adhesive
Millennium PG-1 Low
Viscosity Insulation
Adhesive
Insta Stik Quik Set
Insulation
TABLE 3
Product
Description
Insulation fastener for wood
and steel decks
Galvalume steel plate
Coated, carbon steel screw
Galvalume AZ50 steel plate
Insulation fastener for wood
and steel decks
Polymer fastner
Insulation fastener for wood
and steel.
Galvalume stress plate
Insulation fastener for wood
and steel decks
Insulation and membrane
fastener
Galvalume AZ50 steel plate
Carbon steel fastener
Galvalume stress plate.
A2-SS aluminized steel plate
Polyurethane two component
high rise insulation adhesive
Polyurethane two component
high rise insulation adhesive
Polyurethane two component
low rise insulation adhesive
Polyurethane one component
moisture curing adhesive
Manufacturer
Dimensions (With Current NOA)
various Altenloh, Brinch & Co. U.S.,
Inc.
3" round Altenloh, Brinch & Co. U.S.,
Inc.
various CertainTeed Corp.
3" round CertainTeed Corp.
various CertainTeed Corp.
I" long Simplex Nails, Inc.
various OMG, Inc.
3" round OMG, Inc.
various Altenloh, Brinch & Co. U.S.,
Inc.
Various OMG, Inc.
3" round OMG, Inc.
Various OMG, Inc.
3" square OMG, Inc.
3" square OMG, Inc.
1.5 liters H.B. Fuller Company
1.5 liters H.B. Fuller Company
1.5 liters H.B. Fuller Company
It is supplied The Dow Chemical Company
in pressurized
cylinders with
a net weight
of 23 lbs.,
with a total
unit weight of
30 lbs.
NOA No.: 18-1127.18
Expiration Date: 06/19/23
Approval Date: O1/17/19
Page 6 of 49
t
APPROVED FASTENERS/ADHESIVES:
Fastener Product
Number Name
19. OMG OlyBond 500
Adhesive
20. OMG OlyBond 500 Green
Adhesive
TABLE 3
Product
Description
Spray polyurethane foam
insulation adhesive
Spray polyurethane foam
insulation adhesive
Dimensions
10 gal. bag -in -
box set and
SpotShot
cartridge
10 gal. bag -in -
box set and
1.5 liters
SpotShot
cartridge
Manufacturer
(With Current NOA)
OMG, Inc.
OMG, Inc.
APPROVED SURFACING/COATING OPTIONS:
TABLE 4
Chosen components must be applied according to manufacturer's application instructions. Any coating, listed
below, used as a surfacing, must be listed within a current NOA.
System Number Manufacturer Application
1. Generic Gravel applied at 400 lbs/sq., adhered with flood coat of asphalt at
60 lbs/sq.
2. Generic Slag applied at 300 lbs/sq., adhered with flood coat of asphalt at 60
lbs/sq.
3. Karnak Corp. Karnak (#97 AF) Fibrated Aluminum Roof Coating applied at an
application rate of 1.5 gal/sq.
4. CertainTeed Corp. F1intCoat A-150 applied at an application rate of 1.5 gal/sq.
5. Gardner Asphalt Corp. APOC #212 Fibered Aluminum Roof Coating applied at an
application rate of 1.5 gal/sq.
6. Gardner Asphalt Corp. APOC #400 Sunbrite applied at an application rate of 3 gal./sq.
NOA No.: 18-1127.18
Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 7 of 49
v
EVIDENCE SUBMITTED:
Test Agency/Identifer Name Report Date
Factory Mutual Research Corp.
FM 4470
3Y8A1.AM
03/23/96
FM 4470
OD3A3.AM
04/04/97
FM 4470
1D7A4.AM
11/09/98
FM 4470
2DOAO.AM
12/23/98
--
FM 4470
3024311
11101-106
FM 4470
3031350
09/27/07
FM 4470
3036182
07/31/09
FM 4470
3039046
06/15/10
FM 4470
3048520
09/19/13
Underwriters Laboratories, Inc.
UL 790
R11656
01/11/13
United States Testing Company
ASTM D 5147
97-457-2R
12/02/87
ASTM D 5147
97-4574
06/03/88
Momentum Technologies, Inc.
ASTM D 6164
AX31G8F
06/05/09
TrinitylERD
TAS 114 (J)
3507.08.99-1
04/18/01
TAS 114 (J)
3504.06.01-1
06/05/01
TAS 114
3521.07.04
07/29/04
TAS 114
3533.01.06
01/06/06
TAS 114 (H)
Letter
04/05/06
TAS 117 (B)
3503.10.06
10/10/06
TAS 117 (13)
06490.04.07-R1
06/27/07
TAS 117 (B) / ASTM D 6862
C8500SC.11.07
11/30/07
FM 4470, TAS 114, FM 4470,
C8370.08.08-R1
10/05/09
TAS 114 (J)
TAS 114 (H), TAS 117 (B), TAS
C30560.06.10
06/10/10
114 (J)
FM 4470, TAS 114
C32830.07.10
07/20/10
ASTM D 6164 / D 4798
C31410.01.11-2
01/10/11
TAS 117 B
C35500.02.11
02/09/11
FM 4470 (K) / TAS 114 (J)
03515.07.03-1-R1
06/27/12
ASTM D 1876, TAS 114 (14),
C42110.08.12
08/13/12
TAS 117 (B)
FM 4474 / TAS 114
C39670.08.12
08/20/12
ASTM D 4601
C40050.09.12-1
09/28/12
ASTM D 1970
C40050.09.12-2
09/28/12
ASTM D 5147 / D 4798
C31410.10.10-R1
11/O1/12
ASTM D 5147 / D 4798
C31410.01.11-1-R1
11/O1/12
ASTM D 4798
C31410.01.11-2A-Rl
02/21/13
ASTM D 4798
C31410.12.13
12/05/13
ASTM D 6222
C40050.12.13-R1
12/31/13
TAS 117, TAS 114
C30310.12.09-R1
03/07/14
ASTM D 2178
C47250.03.14
03/26/14
ASTM D 1876, TAS 114 (H),
C45620.03.14
03/27/14
FM 4474
NOA No.: 18-1127.18
Expiration Date: 06/19/23
Approval Date: O1/17119
Page 8 of 49
EVIDENCE SUBMITTED:
Test Agency/Identifier
Name
Report
Date
ASTM D4601
CTR-SC8740.04.15-R2
04/21/15
ASTM D 1876, TAS 114 (H),
C47320.03.14-R1
04/O1/15
FM 4474
ASTM D 1876
C35460.05.11-R1
05/20/15
FM-4474-(D) /-UL 1897_/ TAS
-CT-R-SC10420.01.16- -
01/25/16
114 (J)
FM 4474 / TAS 114 (J)
CTR-SC9175.0916-2
09/06/16
FM 4470 (K) / UL 1897 / TAS
CTR-SC11590.08.16-
09/06/16
114 (J)
RI
ASTM D 4601-04 (2012), Type lI
CTR-SC11145.09.16-
09/19/16
3C
ASTM D 4601-04 (2012), Type II
CTR-SCI 1145.09.16-
09/19/16
3A
ASTM D 6163
CTR-SC11145.09.16-
09/19/16
5A
ASTM D 6222
CTR-SC11145.09.16-
09/19/16
7A
PRI Construction Materials
ASTM D 6163
CTC-056-02-01
08/25/10
Technologies LLC
ASTM D 6163
CTC-066-02-01
08/09/11
ASTM D 6222
CTC-071-02-01
08/08/11
ASTM D 6164 / D 4798
CTC-093-02-01
08/09/11
ASTM D 4601
CTC-126-02-01
03/12/12
ASTM D 2178
CTC-123-02-01
03/13/12
ASTM D 4601
CTC-127-02-01
03/13/12
ASTM D 6163
CTC-128-02-01
06/11/12
ASTM D 6163
CTC-129-02-01
06/11/12
ASTM D 6164
CTC-132-02-01
06/11/12
ASTM D 6164
CTC-161-02-01
05/09/13
ASTM D 6162
CTC-183-02-01
10/02/13
ASTM D 6164
CTC-190-02-01
12/02/13
ASTM D 1970
CTC-199-02-01
01/22/14
ASTM D 6163
CTC 319-02-01
08/22/17
NOA No.: 18-1127.18
Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 9 of 49
APPROVED ASSEMBLIES:
Membrane Type: APP Modified
Deck Type 1I: Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 6" o.c. at
wood joists spaced maximum 24" o.c.
System Type-A(1):—Anchor-sheet-mechanically-fastened, all layers -of -insulation adhered -with -approved -asphalt.
All General and System Limitations apply.
Anchor Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base
Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base
Sheet or Flintglas Premium Ply 6 mechanically attached as detailed below.
Fastening: Anchor sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved
tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c.
One or more layers of any of the following insulations.
Insulation Laver Insulation Fasteners Fastener
able 3 Density/ft2
ACFoam-11, ACFoam-III, F1intBoard ISO, FlintBoard ISO Cold, Multi -Max FA-3, ENRGY 3,13-Shield,
FlintBoarda ISO
Minimum 1.5" thick N/A N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the
EVT range and at a rate of 20-40 lbs./100 ff. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer
of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be
used as a top layer placed with the polyisocyanurate side facing down.
Base Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered to the
insulated substrate.
Ply Sheet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS, Glasbase Base Sheet,
(Optional) Flexiglas Base Sheet, Flintlastic Base 20 or Flintlastic Poly SMS Base or one or more plies of
Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to the base sheet in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one ply of
Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or Flintlastic STA or
Flintlastic APP Base T torch adhered.
Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-
P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base or ply sheet with approved
mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR
Cap 30 T torch adhered.
Or
One ply of Flintlastic GTA or Flintlastic GTA-FR torch adhered to base or ply sheet.
NOA No.:,18-1127.18
Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 10 of 49
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -52.5 psf (See General Limitation #7)
Pressure:
NOA No.: 18-1127.18
MIAM4nAn, COUNTY Expiration Date: 06/1923
Approval Date: O1/17/19
Page 11 of 49
Membrane Type: SBS Modified
Deck Type 1I: Wood, Insulated
Deck Description: i9/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 6" o.c. at
wood joists spaced maximum 24" o.c.
System Type A(2): Anchor sheet mechanically fastened; all layers of insulation adhered with approved asphalt.
All General and System Limitations apply.
Anchor Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base
Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase
Base Sheet or Flintglas Premium Ply 6 mechanically attached as detailed below.
Fastening: Anchor sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and
approved tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c.
One or more layers of any of the following insulations.
Insulation Laver Insulation Fasteners Fastener
Table 3 ' Density/ftx
ACFoam-II, ACFoam-III, FlintBoard ISO, FlintBoard ISO Cold, ENRGY 3, ENRGY 3 25 PSI, H-Shield,
FlintBoarda ISO
Minimum 1.5" thick N/A N/A
FescoBoard
Minimum %" thick N/A N/A
Structodek High Density Fiberboard Roof Insulation
Minimum''/2" thick N/A N/A
DensDeck, DensDeck Prime
Minimum''/," thick N/A N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the
EVT range and at a rate of 20-40 lbs./100 ftz. Please refer to Roofing Application Standard PAS 117 for
insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer
of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be
used as a top layer placed with the polyisocyanurate side facing down.
Base Sheet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase
Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet
adhered to the insulated substrate in a full mopping of approved asphalt applied within the
EVT range and at a rate of 20-40 lbs./sq
NOA No.: 18-1127.18
MAMFDADE COUNTY
... � � Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 12 of 49
Ply Sheet:
One ply of All Weather/Empire Base Sheet, Glasbase Base Sheet, Flexiglas Base Sheet,
(Optional)
Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet
or one or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to base sheet in a
full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq.
or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or
Flintlastic Ultra Poly SMS Base Sheet torch applied.
Membrane:
One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium
FR-P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base/ply sheet with approved
mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic
FR Cap 30 T torch adhered to base or ply sheet.
Surfacing:
Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -52.5 psf (See General Limitation #7)
Pressure:
NOA No.: 18-1127.IS
Expiration Date: 06/19/23
Approval Date: O1/17/19
Page 13 of 49
Membrane Type: APP Modified
Deck Type 1I: Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 6" o.c. at
wood joists spaced maximum 24" o. c.
System Type A(3): Anchor sheet mechanically fastened; all layers of insulation adhered with approved asphalt.
All -General and -System Limitations apply.
Anchor Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base
Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base
Sheet, Flintglas Premium Ply 6 mechanically attached as detailed below.
Fastening: Anchor sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved
tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c.
One or more layers of any of the following insulations.
Insulation Laver Insulation Fasteners Fastener
Table 3 Density/ft2
ACFoam-H, ACFoam-HI, FlintBoard ISO, FlintBoard ISO Cold, Multi -Max FA-3, ENRGY 3, H-Shield,
FlintBoardn ISO
Minimum 1.5" thick N/A N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the
EVT range and at a rate of 2040 lbs./100 fe. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer
of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be
used as a top layer placed with the polyisocyanurate side facing down.
Base Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered to the
insulated substrate.
Ply Sheet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase
(Optional) Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20 or Flintlastic Poly SMS Base, Sheet or one
or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to the base sheet in a full
mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq. or one
ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or Flintlastic STA
or Flintlastic APP Base T torch adhered.
Membrane: Flintlastic GTA or Flintlastic GTA-FR torch adhered to base or ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -60 psf. (See General Limitation /t7)
Pressure:
NOA No.: 18-1127.18
Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 14 of 49
Membrane Type: SBS Modified
Deck Type 1I: Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 6" o.c. at
wood joists spaced maximum 24" o. c.
System Type A(4): Anchor sheet mechanically fastened; all layer of insulation adhered with approved asphalt.
All -General and -System Limitations apply. -
Anchor Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base
Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base
Sheet or Flintglas Premium Ply 6 mechanically attached as detailed below.
Fastening: Anchor sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved
tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c.
One or more layers of any of the following insulations.
Insulation Laver Insulation Fasteners Fastener
Table 3 Density/ff
ACFoam-H, ACFoam-III, FlintBoard ISO, FlintBoard ISO Cold, ENRGY 3, ENRGY 3 25 PSI, H-Shield,
FlintBoardn ISO
Minimum 1.5" thick N/A N/A
FescoBoard
Minimum'/<" thick N/A N/A
Structodek High Density Fiberboard Roof Insulation
Minimum''/z" thick N/A N/A
DensDeck, DensDeck Prime
Minim am %" thick N/A N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the
EVT range and at a rate of 20-401bs./100 ft2. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer
of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be
used as a top layer placed with the polyisocyanurate side facing down.
Base Sheet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase
Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet adhered
to the insulated substrate in a full mopping of approved asphalt applied within the EVT range
and at a rate of 20-40 lbs./sq.
NOA No.: 18-1127.18
Expiration Date: 06/19/23
Approval Date: O1/17/19
Page 15 of 49
Ply Sheet: One ply of All Weather/Empire Base Sheet, Glasbase Base Sheet, Flexiglas Base Sheet,
(Optional) Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or
one or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to the base sheet in a
full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq. or
one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or Flintlastic
Ultra Poly SMS Base Sheet torch applied.
Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-
P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base or ply sheet with approved
mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR
Cap 30 T torch adhered to base/ply sheet.
Surfacing: Any of the approved sw facing/coating options listed in Table 4.
(Optional)
Maximum Design . -60 ps£ (See General Limitation #7)
Pressure:
NOA No.: 15-1127.18
Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 16 of 49
Membrane Type: APP Modified
Deck Type 1I: Wood, Insulated
Deck Description: 15/32" or greater CDX plywood or wood plan attached with #8 screws spaced 6" o.c. at wood
joists spaced maximum 24" o.c.
System Type B(1): Base layer of insulation mechanically fastened, top layer adhered with approved adhesive.
All General and System Limitations apply.
One or more layers of any of the following insulations.
Base Insulation Laver Insulation Fasteners Fastener
Table 3 Density/ft'
ACFoam-II, ACFoam-HI, FlintBoard ISO, FlintBoard ISO Cold, H-Shield, FlintBoarda ISO
Minimum 1.5" thick 1,3 1:1.33 ftz
Note: Base layer shall be mechanically attached with fasteners and density described above. Insulation panels
Hated are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be
increased maintaining the same fastener density (See Roofing Application Standard RAS 117 for fastening
details).
Too Insulation Laver
Insulation Fasteners Fastener
able 3 Density/ft2
ACFoam-H, ACFoam-III, FlintBoard ISO, FlintBoard ISO Cold, H-Shield, FlintBoarda ISO
Minimum 1.5" thick N/A N/A
Note: Top layer of insulation shall be adhered with Millennium One Step Foamable Adhesive, Millennium One
Step Green Foamable Adhesive, Millennium PG-1 Low Viscosity Insulation Adhesive in 3/4" — 1" wide beads
spaced 12 inch o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Base Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA, self -adhered to the
insulated substrate.
Ply Sheet: One or more plies of Flintlastic APP Base T or Flintlastic STA, torch adhered to the base sheet.
Membrane: One ply of Flintlastic GTA or Flintlastic GTA-FR torch adhered to the ply sheet.
Surfacing: Any of theapproved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -67.5 psf (See General Limitation #7)
Pressure:
NOA No.: 18-1127.18
Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 17 of 49
Membrane Type: APP Modified
Deck Type 1I: Wood, Insulated
Deck Description: 15/32" or greater CDX plywood or wood plank attached with #8 screws spaced 6" o.c. at
wood joists spaced maximum 24" o.c.
System Type B(2): Base layer of insulation mechanically fastened, top layer adhered with approved
All General and System Limitations apply.
One or more layers of any of the following insulations.
Base Insulation Laver Insulation Fasteners Fastener
able 3 Density/ft'
ACFoam-H, ACFoam-III, F1intBoard ISO, FlintBoard ISO Cold, H-Shield, FlintBoarda ISO
Minimum 1.5" thick 1,3 1:1.33 fe
Note: Base layer shall be mechanically attached with fasteners and density described above. Insulation panels
listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be
increased maintaining the same fastener density (See Roofing Application Standard RAS 117 for fastening
details).
Top Insulation Laver
SECUROCK Gypsum -Fiber Roof Board
Minimum'/4" thick
Insulation Fasteners Fastener
able 3 Density/W
N/A N/A
Note: Top layer of insulation shall be adhered with Millennium One Step Foamable Adhesive, Millennium One
Step Green Foamable Adhesive, Millennium PG-1 Low Viscosity Insulation Adhesive, Insta-Stik Quik Set
Insulation Adhesive, OMG OlyBond 500 Adhesive or OMG OlyBond 500 Green Adhesive in 3/4" — 1" wide
beads spaced 12 inch o.c. Please refer to Rooting Application Standard RAS 117 for insulation attachment.
Base Sheet: One ply of Flintlastic STA or Flintlastic APP Base T, torch adhered to the insulated substrate.
Ply Sheet: One ply of Flintlastic STA or Flintlastic APP Base T, torch adhered to the base sheet.
(Optional)
Membrane: One ply of Flintlastic GTA or Flintlastic GTA-FR, torch adhered to base or ply sheet.
Surfacing: Any of the approved surfacingicoating options listed in Table 4.
(Optional)
Maximum Design -90 psf (See General Limitation #7)
Pressure:
MIAMFDADECOUN7Y
...ll
NOA No.: 18-1127.18
Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 18 of 49
Membrane Type: SBS/APP Modified
Deck Type 1I: Wood, Insulated
Deck Description: 15/32" or greater APA rated CDX plywood or wood plank attached with 8d ring shank
nails spaced 6" o.c. at wood joists spaced maximum 24" o.c.
System Type C(1): All layers of insulation simultaneously attached.
All -General -and -System -Limitations -apply.
One or more layers of any of the following insulations.
Base Insulation Laver (Optional) Insulation Fasteners
Table 3
ACFoam-II, ACFoam-III, FlintBoard ISO, FlintBoard ISO Cold
Minimum 1.5" thick N/A
Note: All layers shall be simultaneously fastened; see top -layer below for fasteners and density.
Too Insulation Laver Insulation Fasteners
Table 3
ACFoam-II, ACFoam-III, FlintBoard ISO, FlintBoard ISO Cold
Minimum 1.5" thick 2 with 9 or 4 with 5
Fastener
Density/fe
N/A
Fastener
Density/ft2
1:1.6 ft2
Note: Top insulation layer shall be mechanically attached using the fastener density listed above. The insulation
panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be
increased maintaining the same fastener density. Insulation fasteners shall be tested for withdrawal resistance
in compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load
requirements. Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Primer: FlintPrime primer applied at a rate of 0.5 gal/sq and allowed to dry prior to application of base
sheet.
*Required only for Flintlastic SA PlyBase or Flintlastic SA Mid Ply.
Base Sheet: One ply of Flintlastic SA PlyBase or Flintlastic SA Mid Ply, self -adhered to the insulated
substrate.
*Requires use of self -adhering sheet overtop.
Or
One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA, torch applied to the
insulated substrate.
*Requires use of torch -applied sheet overtop.
Ply Sheet: One ply of Flintlastic SA P1yBase or Flintlastic SA Mid Ply, self -adhered to the base sheet.
(Optional) *Requires use of self -adhering sheet overtop.
Or
One ply of Flintlastic Ultra Poly SMS Base Sheet, Flintlastic Base 20 T, Flintlastic APP Base T
or Flintlastic STA torch adhered to the base sheet.
*Requires use of torch -applied sheet overtop.
NOA No.: 18-1127.18
Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 19 of 49
Membrane: Flintlastic FR Cap 30 T, Flintlastic GTA or Flintlastic GTA+R torch adhered to base or ply
sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
-Maximum Design52.5_psf(See-General-Limitation47)
Pressure:
NOA No.: 18-1127.18
Expiration Date: 06/19/23
Approval Date: O1/17/19
Page 20 of 49
Membrane Type: APP Modified
Deck Type 1I: Wood, Insulated
Deck Description: 15132" or greater CDX plywood or wood plank attached with #8 screws spaced 6" o.c. at
wood joists spaced maximum 24" o.c.
System Type C(2): All layers of insulation simultaneously attached.
All -General -and System -Limitations app .
One or more layers of any of the following insulations.
Base Insulation Laver Insulation Fasteners Fastener
Table 3 Density/ft2
ACFoam-II, ACFoam-HI, FlintBoard ISO, FlintBoard ISO Cold, H-Shield, FlintBoardu ISO
Minimum 1.5" thick N/A N/A
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Too Insulation Laver Insulation Fasteners Fastener
able 3 Density/ff
SECUROCK Gypsum -Fiber Roof Board
Minimum 1/4' thick 1,3 1:1.33 ftz
Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The
insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners
shall be increased maintaining the same fastener density. Insulation fasteners shall be tested for withdrawal
resistance in compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load
requirements. Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Base Sheet: One ply of Flintlastic STA or Flintlastic APP Base T, torch adhered to the insulated substrate.
Ply Sheet: One ply of Flintlastic STA or Flintlastic APP Base T, torch adhered to the base sheet.
(Optional)
Membrane: One ply of Flintlastic GTA or Flintlastic GTA-FP, torch adhered to base or ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -67.5 psf (See General Limitation #7)
Pressure:
NOA No.: 18-1127.18
MIAMMADE COUNTY -
, Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 21 of 49
Membrane Type: APP Modified
Deck Type 1I: Wood, huulated
Deck Description: 15/32' or greater CDX plywood or wood plank attached with #8 screws spaced 6" o.c. at wood
joists spaced maximum 24" o.c.
System Type C(3): All layers of insulation simultaneously attached.
All General and System Limitations apply.
One or more layers of any of the following insulations.
Base Insulation Laver Insulation Fasteners Fastener
Table 3 Density/ft'
ACFoam-II, ACFoam-III, FlintBoard ISO, FlintBoard ISO Cold, H-Shield, FlintBoardn ISO
Minimum 1.5" thick N/A N/A
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Ton Insulation Laver Insulation Fasteners Fastener
Table 3 Density/fe
ACFoam-Il, ACFoam-HI, FlintBoard ISO, FlintBoard ISO Cold, H-Shield, FlintBoardn ISO
Minimum 1.5" thick 1, 3 1:1.33 fe
Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The
insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners
shall be increased maintaining the same fastener density. Insulation fasteners shall be tested for withdrawal
resistance in compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load
requirements. Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Base Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA, self -adhered to the
insulated substrate.
Ply Sheet: One or more plies of Flintlastic APP Base T or Flintlastic STA, torch adhered to the base sheet.
Membrane: One ply of Flintlastic GTA or Flintlastic GTA-FR torch adhered to ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -75.0 psf (See General Limitation #7)
Pressure:
NOA No.: 18-1127.18
MIAMI-DADECOUNTY
• .. � � Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 22 of 49
Membrane Type: SBS Modified
Deck Type 1I: Wood, Insulated
Deck Description: 15/32" or greater APA rated CDX plywood or wood plank attached with 8d ring shank nails
spaced 6" o.c. at wood joists spaced maximum 24" o.c.
System Type D(1): All layers of insulation and base sheet simultaneously attached.
—All General and System Limitations apply.
One or more layers of any of the following insulations.
Insulation Laver
Any Approved Polyisocyanurate Listed in Table 2
Minimum 1.5" thick
Insulation Fasteners Fastener
Table 3 Densitv/fe
N/A N/A
Note: Insulation layer shall have preliminary attachment, prior to the installation of the base sheet, at an
application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and
four fasteners for any insulation board having no dimension greater than 8 ft. All layers of insulation and base
sheet shall be simultaneously fastened. See base sheet below for fasteners and density.
Base Sheet: One ply of Glasbase Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Yosemite
Venting Base Sheet, Flintlastic Poly SMS Base Sheet and Flintlastic Ultra Poly SMS Base
Sheet, mechanically attached as described below.
Fastening #1: Trufast #12 DP Fasteners or Trufast #14 HD Fasteners with Trufast 3" Metal Insulation
Plates, F1intFast #12 fasteners or F1intFast #14 fasteners with F1intFast 3" Insulation Plates
spaced 8" o.c, at the 4" wide laps and 8" o.c. in three, equally spaced staggered center rows.
Ply Sheet: One ply of Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly
(Optional) SMS Base Sheet applied in FlintBond Brush at a rate of 1.0 — 1.5 gal/sq to the base sheet.
Membrane: One ply of Flintlastic Cap 30, Flintlastic FR Cap 30, Flintlastic FR Dual Cap, Flintlastic FR-
P, Flintlastic Premium FR-P or Flintlastic GMS applied in FlintBond Brush at a rate of 1.0 —
1.5 gal/sq to base or ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -52.5 psf (See General Limitation #7)
Pressure:
NOA No.: 18-1127.18
Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 23 of 49
Membrane Type:
Deck Type 1I:
Deck Description:
System Type D(2):
SBS Modified
Wood, Insulated
15/32" or greater APA rated plywood or wood plank attached with #10 wood screws spaced 6"
o.c. at wood joists spaced maximum 24" o.c.
All layers of insulation and base sheet simultaneously attached.
All General and System Limitations apply.
One or more layers of any of the following insulations.
Insulation Laver
Any Approved Polyisocyanurate Listed in Table 2
Minimum 1.5" thick
Insulation Fasteners Fastener
able 3 Density/ftz
N/A N/A
Note: Insulation layer shall have preliminary attachment, prior to the installation of the base sheet, at an
application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and
four fasteners for any insulation board having no dimension greater than 8 ft. All layers of insulation and base
sheet shall be simultaneously fastened. See base sheet below for fasteners and density.
Base Sheet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, All Weather/Empire Base
Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic
Ultra Poly SMS Base Sheet, mechanically attached as described below.
Fastening #1: Fastened with Trufast #14 HD Fasteners with Trufast 3" Metal Insulation Plates or F1intFast
#14 Fasteners with FlintFast 3" Insulation Plates spaced 8" o.c. at the 4" wide laps and 8" o.c.
in three, equally spaced staggered center rows.
Ply Sheet One ply of Glasbase Base Sheet, All Weather/Empire Base Sheet, Flexiglas Base Sheet,
(Optional): Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet
adhered to base sheet in a full mopping of approved asphalt applied within the EVT range and
at a rate of 2040 lbs./sq. or one ply of Glasbase Base Sheet, All Weather/Empire Base Sheet,
Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Base 20 T or Flintlastic Ultra Poly SMS
Base torch applied to base sheet or one ply of Black Diamond Base Sheet or Flintlastic Ultra
Glass SA self -adhered to the base sheet.
Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-
P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base or ply sheet with approved
mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or one ply of
Flintlastic FR Cap 30 T torch adhered to base or ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -97.5 psf. (See General Limitation #7)
Pressure:
NOA No.: 18-1127.18
Expiration Date: 06/1923
Approval Date: 01/17/19
Page 24 of 49
Membrane Type: SBS Modified
Deck Type 1: Wood, Non -insulated
Deck Description: 15/32' or greater CDX plywood or wood plank attached with 8d ring shank nails spaced 6" o.c at
wood joists spaced maximum 24" o.c.
System Type E(1): Base sheet mechanically fastened.
All -General and System -Limitations apply. - -
Base Sheet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, All
Weather / Empire Base Sheet, Flintlastic Base 20 or Flintlastic Poly SMS Base Sheet
mechanically attached as detailed below.
Fastening #1: Fastened with Simplex MAXX Cap fasteners spaced 9" o.c. in the 2" side lap and 12" o.c. in
two evenly divided, staggered rows in the center of the sheet.
Membrane: One ply of Flintlastic Cap 30, Flintlastic FR Cap 30, Flintlastic FR Dual Cap, Flintlastic FR-P,
Flintlastic Premium FR-P or Flintlastic GMS adhered to the base sheet with approved mopping
asphalt applied within the EVT range and at a rate of 20-40 lbs/sq. or one ply of Flintlastic FR
Cap 30 T,torch-applied to base sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -52.5 psf (See General Limitation #9)
Pressure:
NOA No.: 18-1127.18
Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 25 of 49
Membrane Type: APP Modified
Deck Type 1: Wood, Non -insulated
Deck Description: 15/32 " or greater CDX plywood or wood plank attached with 8d ring shank nails spaced 6" o.c.
at wood joists spaced maximum 24" o.c.
System Type E(2): Base sheet mechanically fastened.
AllGme—ral a�ltn -System Limitations apply.
Base Sheet: One ply of Flintlastic APP Base T mechanically attached as detailed below.
Fastening #1: Fastened with Simplex MAXX Cap fasteners spaced 9" o.c. in the 2" side lap and 12" o.c. in
two evenly divided, staggered rows in the center of the sheet.
Membrane: One ply of Flintlastic FR Cap 30, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium
FR-P or Flintlastic GMS adhered to the base sheet with approved mopping asphalt applied
within the EVT range and at a rate of 2040 lbs/sq. or one ply of Flintlastic FR Cap 30 T, torch -
applied to base sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -52.5 psf (See General Limitation #9)
Pressure:
NOA No.: 18-1127.18
Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 26 of 49
Membrane Type: APP Modified
Deck Type 1: Wood, Non -Insulated
Deck Description: 19/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 6" o.c. at
wood joists spaced maximum 24" o.c.
System Type E(3): Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base
Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base
Sheet or Flintglas Premium Ply 6 mechanically attached as detailed below.
Fastening #1: Base sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin
caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c.
Ply Sheet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase
(Optional) Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or one
or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to the base sheet in a full
mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq. or one
ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or Flintlastic STA
or Flintlastic APP Base T torch adhered.
Membrane: Flintlastic GTA or Flintlastic GTA-FR torch adhered to base or ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -52.5 psf. (See General Limitation #7)
Pressure:
NOA No.: 18-1127.18
Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 27 of 49
F embiane', vL3en , S Modied�
rDeckTq j;. %354d,Nondmulated-�
Deck Description: 19/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 6" o.c. at
wood joists spaced maximum 24" o.c.
System Type E(4): Base sheet mechanically fastened,
All General -and System Limitations apply.
Base Sheet: - One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base
Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base
Sheet or Flintglas Premium Ply 6 mechanically attached as detailed below.
Fastening #1: Base sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin
caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c.
Ply Sheet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase
(Optional) Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or one
or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to the base sheet in a full
mopping of approved asphalt applied within the EVT range and at a rate of20-40 lbs./sq. or one
ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or Flintlastic Ultra
Poly SMS Base Sheet torch adhered.
Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-
P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base or ply sheet with approved
mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR
Cap 30 T torch adhered to base or ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -52.5 psf. (See General Limitation #7)
Pressure:
A No�8=1127.18
Expir lion��D..a,te D6 9/23
ApprovarD [ wig
Page:2� 49
Membrane Type: SBS Modified
Deck Type 1: Wood, Non -Insulated
Deck Description: 15/32" or greater CDX plywood or wood plank attached with #8d ring shank nails spaced 6" o.c.
at wood joists spaced 24" o.c.
System Type E(5): Base sheet mechanically fastened.
All General dud -System Limitations apply.
Base Sheet: One ply of Glasbase Base Sheet or Yosemite Venting Base Sheet, mechanically attached as
described below.
Fastening #1: Fastened with FBC HVHZ nails and tin caps spaced 6" o.c. at the 3" lap and 6" o.c. in four,
equally spaced staggered center rows.
Ply Sheet: One or more plies of Glasbase Base Sheet, All Weather/Empire Base Sheet, Flexiglas Base
(Optional) Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base
Sheet adhered to the base sheet in a full mopping of approved asphalt applied within the EVT
range and at a rate of 20-40 lbs./sq. or one or more plies of Flintlastic Base 20 T or Flintlastic
Ultra Poly SMS Base Sheet, torch applied.
Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-
P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base or ply sheet with approved
mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or one ply of
Flintlastic FR Cap 30 T torch adhered to base or ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -52.5 psf. (See General Limitation #7)
Pressure:
NOA No.: 18-1127.18
Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 29 of 49
Membrane Type: SBS Modified
Deck Type 1: Wood, Non -Insulated
Deck Description: 15/32" or greater APA rated CDX plywood or wood plank attached with 8d ring shank nails
spaced 6" o.c. at wood joists spaced maximum 24" o.c.
System Type E(6): Base sheet mechanically fastened
All General and System Limitations apply.
Base Sheet: One ply of Glasbase Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Yosemite Venting
Base, Flintlastic Poly SMS Base and Flintlastic Ultra Poly SMS Base, mechanically attached as
described below.
Fastening #1: Trufast #12 DP Fasteners or Trufast #14 HD Fasteners with Trufast 3" Metal Insulation Plates,
F1intFast #12 fasteners or F1intFast #14 fasteners with F1intFast 3" Insulation Plates spaced 8"
o.c. at the 4" wide laps and 8" o.c. in three, equally spaced staggered center rows.
Ply Sheet One ply of Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS
(Optional): Base Sheet applied in FlintBond Brush at a rate of 1.0 — 1.5 gal/sq. to the base sheet.
Membrane: One ply of Flintlastic Cap 30, Flintlastic FR Cap 30, Flintlastic FR Dual Cap, Flintlastic FR-P,
Flintlastic Premium FR-P or Flintlastic GMS applied in F1imBond Brush at a rate of 1.0 — 1.5
gal/sq to base or ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -52.5 psf. (See General Limitation #7)
Pressure:
NOA No.: 18-1127.18
Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 30 of 49
Membrane Type:
Deck Type 1:
Deck Description:
APP Modified
Wood, Non -Insulated
19/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 4" o.c. at
wood joists spaced maximum 24" o.c.
System Type E(7): Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base
Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base
Sheet or Flintglas Premium Ply 6 mechanically attached as detailed below.
Fastening #1: Base sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin
caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c.
Ply Sheet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase
(Optional) Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or one
or more Flintglas Ply 4 or Flintlgas Premium Ply 6 adhered to the base sheet in a full mopping
of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one ply of
Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or Flintlastic STA or
Flintlastic APP Base T torch adhered.
Membrane: Flintlastic GTA or Flintlastic GTA-FR torch adhered to base or ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -60 psf. (See General Limitation #7)
Pressure:
NOA No.: 18-1127.18
MIAMIUU COUNTY
• • • , , Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 31 of 49
Membrane Type: SBS Modified
Deck Type 1: Wood, Non -Insulated
Deck Description: 19/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 4" o.c. at
wood joists spaced maximum 24" o.c.
System Type E(8): Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base
Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base
Sheet or Flintglas Premiam Ply 6 mechanically attached as detailed below.
Fastening #1: Base sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin
caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c.
Ply Sheet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase
(Optional) Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or one
or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to the base sheet in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one
ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or Flintlastic Ultra
Poly SMS Base Sheet torch adhered.
Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-
P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base or ply sheet with approved
mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR
Cap 30 T torch adhered to base or ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -60 psf. (See General Limitation #7)
Pressure:
Mu1MMALDE COUNTY NOA No.: 18-1127.18
•, , Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 32 of 49
Membrane Type: SBS Modified
Deck Type 1: Wood, Non -Insulated
Deck Description: "/32" or greater plywood or wood plank attached with #8 wood screws spaced 6" o.c. at wood
joists spaced at maximum 24" o.c.
System Type E(9): Base sheet mechanically fastened
All General and System Limitations apply.
Separation Sheet: One or more plies of Glasbase Base Sheet, loose laid.
(Optional)
Base Sheet: One or more plies of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexibase Base
Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base
Sheet, mechanically attached as described below.
Fastening #1: Anchor sheet shall be fastened with FBC HVHZ nails and tin caps spaced 6" o.c. at the 3" lap
and 6" o.c. in four, equally spaced staggered center rows.
Ply Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA, self -adhered to the base
sheet.
Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-
P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to ply sheet with approved mopping
asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR Cap 30
T torch adhered to ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -60 psf (See General Limitation #7)
Pressure:
MIAM4DADE COUNTY NOA No.: 18-1127.18
. • • •, � Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 33 of 49
Membrane Type: APP Modified
Deck Type 1: Wood, Non -Insulated
Deck Description: 19/32" or greater plywood or wood plank attached with #8 wood screws spaced 6" o.c, at wood
joists spaced maximum 24" o.c.
System Type E(10): Base sheet mechanically fastened
All General and System Limitations apply.
Separation Sheet: One or more plies of Glasbase Base Sheet, loose laid.
(Optional)
Base Sheet: One or more plies of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexibase Base
Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base
Sheet, mechanically attached as described below.
Fastening #1: Anchor sheet shall be fastened with FBC HVHZ nails and tin caps spaced 6" o.c. at the 3" lap
and 6" o.c. in four, equally spaced staggered center rows.
Ply Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA, self -adhered to the base
sheet.
Membrane: One ply of Flintlastic GTA or Flintlastic GTA-FR torch adhered to ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -60 psf (See General Limitation #7)
Pressure:
NOA No.: 18-1127.18
nu+nEonoe courm Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 34 of 49
Membrane Type: SBS Modified
Deck Type 1: Wood, Non -Insulated
Deck Description: 19/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 6"o.c. at
wood joists spaced maximum 24" o.c.
System Type E(11): Base sheet mechanically fastened
All General and System Limitations apply.
Separation Sheet: One or more plies of Glasbase Base Sheet, loose laid.
(Optional)
Base Sheet: One or more plies of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet,
Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet,
mechanically attached as described below.
Fastening #1: OMG #12 Standard Roofgrip fasteners with OMG 3" Galvanized Steel Plates or AccuTrac
Plates or Trufast #12 DP fasteners with Trufast 3" Metal Insulation Plates or Flintfast 912
fasteners with Flintfast 3" Insulation Plates spaced 7" o.c. at the 4" wide laps and 7" o.c. in two,
equally spaced staggered center rows.
Ply Sheet: One ply of Flintlastic Ultra Glass SA, self -adhered to the base sheet.
Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-
P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to ply sheet with approved mopping
asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR Cap 30
T torch adhered to ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -67.5 psf. (See General Limitation 47)
Pressure:
ML4MIAADE COUNTY
NOA No.: 18-1127.18
• • • � � Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 35 of 49
Membrane Type: SBS Modified
Deck Type 1: Wood, Non -Insulated
Deck Description: - 15/32" or greater APA rated plywood or wood plank attached with #8 screws spaced 6" o.c. at
wood joists spaced maximum 24" o.c.
System Type E(12): Base sheet mechanically fastened
All General and System Limitations apply.
Base Sheet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, All Weather/Empire Base
Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic
Ultra Poly SMS Base Sheet, mechanically attached as described below.
Fastening #1: Cap nails: 1" diameter, 0.032" thick metal cap with 0.120" shank diameter, annular ring shank
nails spaced 6" o.c. at the 4" wide laps and 6" o.c. in five, equally spaced staggered center rows.
Ply Sheet One ply of Glasbase Base Sheet, All Weather/Empire Base Sheet, Flexiglas Base Sheet,
(Optional): Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet
adhered to base sheet in a full mopping of approved asphalt applied within the EVT range and
at a rate of 20-40 lbs./sq. or one ply of Glasbase Base Sheet, All Weather/Empire Base Sheet,
Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Base 20 T or Flintlastic Ultra Poly SMS
Base torch applied to base sheet.
Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-
P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base or ply sheet with approved
mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or one ply of
Flintlastic FR Cap 30 T torch adhered to base or ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -67.5 psf. (See General Limitation #7)
Pressure:
NOA No.: 18-1127.18
Expiration Date: 06/1923
Approval Date: 01/17/19
Page 36 of 49
Membrane Type: SBS Modified
Deck Type 1: Wood, Non -Insulated
Deck Description: 19/32" or greater plywood or wood plank attached with #8 wood screws spaced 6" o.c. at wood
joists spaced maximum 24" o.c.
System Type E(13): Base sheet mechanically fastened
All General and System Limitations apply.
Base Sheet: One or more layers of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base
Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base
Sheet or All Weather/Empire Base Sheet, mechanically attached as described below.
Fastening #1: Anchor sheet shall be fastened with HVHZ nails and tin caps spaced 6" o.c. at the 3" lap and 6
o.c. in four, equally spaced staggered center rows.
Ply Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered to the base
sheet.
Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-
P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to ply sheet with approved mopping
asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR Cap 30
T torch adhered to ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -82.5 psf (See General Limitation #7)
Pressure:
NOA No.: 18-1127.18
Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 37 of 49
Membrane Type: APP Modified
Deck Type 1: Wood, Non -Insulated
Deck Description: 19/32" or greater plywood or wood plank attached with #8 wood screws spaced 6" o.c. at wood
joists spaced maximum 24" o.c.
System Type E(14): Base sheet mechanically fastened
All General and System Limitations apply.
Base Sheet: One or more layers of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base
Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base
Sheet or All Weather/Empire Base Sheet, mechanically attached as described below.
Fastening #1: Anchor sheet shall be fastened with HVHZ nails and tin caps spaced 6" o.c. at the 3" lap and 3
o.c. in four, equally spaced staggered center rows.
Ply Sheet: One ply of Black Diamond Base Sheet, self -adhered to the base sheet.
Membrane: One ply of Flintlastic GTA or Flintlastic GTA-FR torch adhered to ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -82.5 psf (See General Limitation #7)
Pressure:
MAMMADE COUNTY NOA No.: 18-1127.18
FR , Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 38 of 49
Membrane Type: SBS Modified
Deck Type 1: Wood, Non -Insulated
Deck Description: 15/32" or greater CDX plywood or wood plank attached with #10 wood screws spaced 6" o.c. at
wood joists spaced maximum 24" o.c.
System Type E(15): Base sheet mechanically fastened.
All General and -System Limitations apply..
Base Sheet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, All
Weather / Empire Base Sheet, Flintlastic Base 20 or Flintlastic Poly SMS Base Sheet
mechanically fastened with Simplex MAXX Cap fasteners spaced 6" o.c. in the 2" side lap and
6" o.c. in two evenly divided, staggered rows in the center of the sheet.
Membrane: One ply of Flintlastic FR Cap 30, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium
FR-P, Flintlastic Cap 30 or Flintlastic GMS adhered to the base sheet with approved mopping
asphalt applied within the EVT range and at a rate of 20-40 lbs/sq. or one ply of Flintlastic FR
Cap 30 T, torch -applied to base sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -90 psf. (See General Limitation #9)
Pressure:
NOA No.: 18-1127.18
Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 39 of 49
Membrane Type: APP Modified
Deck Type 1: Wood, Non -Insulated
Deck Description: 15/32" or greater CDX plywood or wood plank attached with # 10 wood screws spaced 6" o.c. at
wood joists spaced maximum 24" o.c.
System Type E(16): Base sheet mechanically fastened.
All -General and System Limitations apply.
Base Sheet: One ply of Flintlastic APP Base T mechanically fastened with Simplex MAXX Cap fasteners
spaced 6" o.c. in the 2" side lap and 6" o.c. in two evenly divided, staggered rows in the center
of the sheet.
Membrane: One ply of Flintlastic GTA or Flintlastic GTA-Flt, torch -applied to the base sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -90 psf. (See General Limitation #9)
Pressure:
NOA No.: 18-1127.18
MIAMI-DADECOUNW
Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 40 of 49
Membrane Type: SBS Modified
Deck Type 1: Wood, Non -Insulated
Deck Description: 15/32" or greater CDX plywood or wood plank attached with #10 wood screws spaced 6" o.c. at
wood joists spaced maximum 24" o.c.
System Type E(17): Base sheet mechanically fastened.
All General and -System Limitations apply
Base Sheet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flintlastic Base 20, Flintlastic
Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet mechanically attached as
described below.
Fastening #1: Fastened with Trufast #12 DP Fastener or Trufast #14 HD Fastener with Trufast 3" Metal
Insulation Plate, OMG Heavy Duty fasteners with 3 in. Round Metal Plates, OMG AccutTrac
Hextra with AccuTrac Flat Bottom plates, FlintFast #12 fasteners or FlintFast #14 fasteners
with FlintFast 3" Insulation Plates spaced 6" o.c. at the 4" lap and 6" o.c, in three, equally
spaced staggered center rows.
Ply Sheet: One or more plies of Glasbase Base Sheet, All Weather/Empire Base Sheet, Flexiglas Base
(Optional) Sheet, Flintlastic Base 20, Flintlastic Ultra Poly SMS Base Sheet adhered to the base sheet in a
full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq. or
one or more plies of Flintlastic Base 20 T or Flintlastic Ultra Poly SMS Base Sheet, torch
applied.
Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-
P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base or ply sheet with approved
mopping asphalt applied within the EVT range and at a rate of 20 to 401bs./sq. or one ply of
Flintlastic FR Cap 30 T torch adhered to base or ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -97.5 psf. (See General Limitation #7)
Pressure:
NOA No.: 18-1127.18
Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 41 of 49
Membrane Type: SBS Modified
Deck Type 1: Wood, Non -Insulated
Deck Description: 15/32" or greater APA rated plywood or wood plank attached with # 10 wood screws spaced
6"o.c. at wood joists spaced maximum 24" o.c.
System Type E(18): Base sheet mechanically fastened
All General and System Limitations apply
Base Sheet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, All Weather/Empire Base
Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic
Ultra Poly SMS Base Sheet, mechanically attached as described below.
Fastening #1: Fastened with Tmfast # 14 HD Fasteners with Trufast 3" Metal Insulation Plates or FlintFast
#14 Fasteners with FlintFast 3" Insulation Plates spaced 8" o.c. at the 4" wide laps and 8" o.c.
in three, equally spaced staggered center rows.
Ply Sheet One ply of Glasbase Base Sheet, All Weather/Empire Base Sheet, Flexiglas Base Sheet,
(Optional): Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet
adhered to base sheet in a full mopping of approved asphalt applied within the EVT range and
at a rate of 20-40 lbs./sq. or one ply of Glasbase Base Sheet, All Weather/Empire Base Sheet,
Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Base 20 T or Flintlastic Ultra Poly SMS
Base torch applied to base sheet or one ply of Black Diamond Base Sheet or Flintlastic Ultra
Glass SA self -adhered to base sheet.
Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-
P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base or ply sheet with approved
mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or one ply of
Flintlastic FR Cap 30 T torch adhered to base or ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -97.5 psf. (See General Limitation #7)
Pressure:
NOA No.: 18-1127.18
Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 42 of 49
Membrane Type: SBS Modified
Deck Type 1: Wood, Non -Insulated
Deck Description: 15/32" or greater CDX plywood or wood plank attached with # 10 wood screws spaced 4" o.c. at
wood joists spaced maximum 24" o.c.
System Type E(19): Base sheet mechanically fastened.
All General and System Limitations apply
Base Sheet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, All
Weather / Empire Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet
mechanically fastened with Simplex MAXX Cap fasteners spaced 6" o.c. in the 2" side lap and
6" o.c. in three evenly divided, staggered rows in the center of the sheet.
Membrane: One ply of Flintlastic FR Cap 30, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium
FR-P, Flintlastic Cap 30 or Flintlastic GMS adhered to the base sheet with approved mopping
asphalt applied within the EVT range and at a rate of 2040 lbs/sq. or one ply of Flintlastic FR
Cap 30 T, torch -applied.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -105 psi (See General Limitation #9)
Pressure:
MIAMI•DADE COUNTY
NOA No.: 18-1127.18
. • • • . , Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 43 of 49
Membrane Type: APP Modified
Deck Type 1: Wood, Non -Insulated
Deck Description: 15/32" or greater CDX plywood or wood plank attached with # 10 wood screws spaced 4"o.c. at
wood joists spaced maximum 24" o.c.
System Type E(20): Base sheet mechanically fastened.
All -General and -System Limitations apply.
Base Sheet: One ply of Flintlastic APP Base T mechanically fastened with Simplex MAXX Cap fasteners
spaced 6" o.c. in the 2" side lap and 6" o.c. in three evenly divided, staggered rows in the center
of the sheet.
Membrane: One ply of Flintlastic GTA or Flintlastic GTA-FF, torch -applied to the base sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -105 psf. (See General Limitation #9)
Pressure:
NOA No.: 18-1127.18
Expiration Date: 06/1923
Approval Date: O1/17/19
Page 44 of 49
Membrane Type: SBS Modified
Deck Type 1: Wood, Non -Insulated
Deck Description: 19/32" or greater plywood or wood plank attached with #8 wood screws spaced 6" o.c. at wood
joists spaced maximum 24" o.c.
System Type E(21): Base sheet mechanically fastened
All General and System Limitations apply.
Base Sheet: One or more plies of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet,
Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet,
mechanically attached as described below.
Fastening #1: Base sheet shall be fastened with OMG 12 Standard Roofgrip fasteners with OMG 3 in. Round
Metal Plates or AccuTrac Plates or Trufast #12 DP fasteners with Trufast 3" Metal Insulation
Plates or F1intFast #12 Fasteners with F1intFast 3" Insulation Plates spaced 7" o.c, at the 4" lap
and 7 o.c. in three, equally spaced center rows.
Ply Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered to the base
sheet.
Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-
P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to ply sheet with approved mopping
asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR Cap 30
T torch adhered to ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -105.0 psf (See General Limitation 47)
Pressure:
MIAMFDADE COUNTY NOA No.: 18-1127.18
. • • • . � Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 45 of 49
Membrane Type: SBS Modified
Deck Type 1: Wood, Non -Insulated
Deck Description: 19/32" or greater plywood or wood plank attached with 48 wood screws spaced 6" o.c. at wood
joists spaced maximum 24" o.c.
System Type E(22): Base sheet mechanically fastened
All General and System Limitations apply.
Separation Sheet: One ply of Glasbase Base Sheet, loose laid.
(Optional)
Base Sheet: One or more plies of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexibase Base
Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base
Sheet, mechanically attached as described below.
Fastening #1: Base sheet shall be fastened with FBC HVHZ nails and tin caps spaced 4" o.c. at the 3" lap and
4" o.c. in four, equally spaced center rows.
Ply Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA, self -adhered to the base
sheet.
Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-
P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to ply sheet with approved mopping
asphalt applied within the EVT range and at a rate of 20 to 401bs./sq. or Flintlastic FR Cap 30
T torch adhered to ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -105 psf (See General Limitation 47)
Pressure:
NOA No.: 18-1127.18
MIAMI-DADE COUNTY
,.... � Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 46 of 49
Membrane Type: APP Modified
Deck Type 1: Wood, Non -Insulated
Deck Description: 19/32" or greater plywood or wood plank attached with #8 wood screws spaced 6" o.c. at
wood joists spaced maximum 24" o.c.
System Type E(23): Base sheet mechanically fastened
-All General -and -System Limitations apply. -
Separation Sheet: One ply of Glasbase Base Sheet, loose laid.
(Optional)
Base Sheet: One or more plies of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexibase Base
Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS
Base Sheet, mechanically attached as described below.
Fastening #1: Base sheet shall be fastened with FBC HVHZ nails and tin caps spaced 4" o.c. at the 3"
lap and 4" o.c. in four, equally spaced center rows.
Ply Sheet: One ply of Black Diamond Base Sheet, self -adhered to the base sheet.
Membrane: One ply of Flintlastic GTA or Flintlastic GTA-FR torch adhered to ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -105 psf (See General Limitation #7)
Pressure:
NOA No.: 18-1127.18
Expiration Date: 06/19/23
Approval Date: O1/17/19
Page 47 of 49
Membrane Type: SBS Modified
Deck Type 1: Wood, Non -Insulated
Deck Description: "/32" or greater CDX plywood or wood plank attached with #10 wood screws spaced 4" o.c. at
wood joists spaced maximum 24" o.c.
System Type E(24): Base sheet mechanically fastened.
All General and -System Limitation as pp y—
Base Sheet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flintlastic Base 20, Flintlastic
Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet mechanically attached as
described below.
Fastening #1: Fastened with Trufast #12 DP Fastener or Trufast 414 HD Fastener with Trufast 3" Metal
Insulation Plate, OMG Heavy Duty fasteners with 3 in. Round Metal Plates, OMG AccutTrac
Hextra with AccuTrac Flat Bottom plates, FlintFast #12 fasteners or FlintFast #14 fasteners
with FlintFast 3" Insulation Plates spaced 6" o.c. at the 4" lap and 6" o.c. in four, equally
spaced staggered center rows.
Ply Sheet: One or more plies of Glasbase Base Sheet, All Weather/Empire Base Sheet, Flexiglas Base
(Optional) Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base
Sheet adhered to the base sheet in a full mopping of approved asphalt applied within the EVT
range and at a rate of 20-40 lbs./sq. or one or more plies of Flintlastic Base 20 T or Flintlastic
Ultra Poly SMS Base Sheet, torch applied.
Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-
P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base or ply sheet with approved
mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or one ply of
Flintlastic FR Cap 30 T torch adhered to base or ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -127.5 psf. (See General Limitation #7)
Pressure:
MIAMI-DADE COUNTY
�Fj....
NOA No.: 18-1127.18
Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 48 of 49
VJ
WOOD DECK SYSTEM LIMITATIONS:
A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet.
GENERAL LIMITATIONS:
2.-
3.
to
5.
22
91
.0
10.
Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
Insulation may be installed -in multiple Iayers. The first layer shall be attached in compliance with Product Control
Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the
EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer
All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size
shall be 4' x 4' maximum.
An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations
when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot
mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at
each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the
strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt
application of either system shall be at a minimum rate of 12 lbs./sq.
Note: Spot attached systems shall be limited to a maximum design pressure of -45 psE
Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as
tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below
275 Ibf insulation attachment shall not be acceptable.
Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum
fastener resistance value in conjunction with the maximum design value listed within a specific system. Should
the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing,
prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered
Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value
taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application
Standard RAS It 7.
Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener
densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing
Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional
Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred
within this NOA, General Limitation #9 will not be applicable.)
All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to
Roofing Application Standard RAS 111 and applicable wind load requirements.
The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field,
perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at
enhanced pressure zones (i.e. perimeters, extended comers and corners). (When this limitation is specifically
referred within this NOA, General Limitation #7 will not be applicable.)
All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
MIAMI.�FjDADE COUNTY
.... l
END OF THIS ACCEPTANCE
NOA No.: 18-1127.18
Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 49 of 49