Loading...
HomeMy WebLinkAboutNOAcoullTr SCgyNED St Lucie Co DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Unty BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Sheet, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidadc eov/economy Owens Corning Roofing and Asphalt, LLC One Owens Corning Parkway Toledo, OH 43659 THESE PLANS AND ALL PROPOSED WORK SCOPE: FILE C®'1 REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO This NOA is being issued under the applicable rules and regulations governing(Rf�EkY(W T &6&nPri18T0i1�6s ODES_ documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Duration®, Duration® Premium, TruDefinition® Duration®, and TruDefinition® Duration® Designer Colors Collection 1zVV,hfi"P"4o2-DI`f - LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manu shall be available for inspection at the job site at the request of the Building Official. %W�W�tp"" ACHMENTS RESPONSIBILITY OF THE This NOA renews NOA No. 12-0309.01 and consists of pages I through 6. OR OR RECORD The submitted documentation was reviewed by Gaspar J Rodriguez. lob ­ Ids V I MIAM4DADE COUNTY 5 LUCIE COUNTY BUILD G DI NOA No.: 16-0425.01 REVIEWED FOR C0 PLIANC Expiration Date: 07/19/21 REVI�Approval REVI Y Date: 07/21/16 DAT Page 1 of 6 PLANS AND PERMtr MUST BE KEPT JOB SITE OR»»NO INSPECTION(S) WIL MADE ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Asphalt Shingles Materials: Laminate Deck Type: Wood SCOPE - This approves a roofing system using Owens Corning Duration® and Duration® Premium asphalt shingles manufactured by Owens Corning as described in Section 2 of his Notice of Acceptance. PRODUCT DESCRIPTION Product Dimensions Test Specifications Duration® 13 '/4" x 39 3/$ - Manufacturing Locations #1, 2 Duration® Premium; 13 '/4" x 39 3/8" TruDefinition® Duration®; TruDefinition® Duration® Designer Colors Collection Manufacturing Location #1, 2, 3, 4 Duration® 13 %" x 39 3/e" Manufacturing Location #1, 2, 3 Duration® Premium; 13 '/4" x 39 3/8" TruDefinition® Duration®; TruDefinition® Duration® Designer Colors Collection Manufacturing Location #1, 2, 3, 4 MANUFACTURING LOCATION 1. Jacksonville, FL 2. Memphis, TN 3. Savannah, GA 4. Irving, TX Product Description TAS 11 o A heavy weight, fiberglass reinforced four tab asphalt shingle with continuous bead of sealant. TAS 110 A heavy weight, fiberglass reinforced four tab asphalt shingle with large nail area with continuous bead of sealant. TAS 110 A heavy weight, fiberglass reinforced four tab asphalt shingle with dashed bead of sealant. TAS 11 o A heavy weight, fiberglass reinforced four tab asphalt shingle with dashed bead of sealant. MIAMMADECOUNTY NOA No.: 16-0425.01 Expiration Date: 07/19/21 Approval Date: 07/21/16 Page 2 of 6 EVIDENCE SUBMITTED Test oency Test I_ d_ e_ ntifier Test Name/Reoort PRI Asphalt Technologies, Inc. �— Date OCF-157-02-01 OCF-102-02-01 TAS 100 10/26/10 OCF-156-02-01 TAS 100 TAS 100 11/12/07 OCF463=02-01 TAS-100 10/26/10 OCF-164-02-01 TAS 100 12/10/10 OCF-098-02-01 TAS 100 12/10/10 OCF-099-02-01 TAS 100 02/22/07 OCF-102-02-01 TAS 100 02/26/07 OCF-172-02-01 TAS 100 11/12/07 Underwriters Laboratories, Inc. OCF-179-02-01 TAS 100 05/26/11 02/02/12 07CA39536 03NK04954 TAS 107 11/11/07 03NK04954 TAS 107 TAS 107 03/28/03 1ONK13947 TAS 107 /11/ 1111/12/10 1ICA15662 TAS 107 05/27/11 11NB21712 TAS 107 02/18/12 07CA02026 ASTM D 3462 01 6/ /207 12CA12180 ASTM D 3462 0//07 LIMITATIONS I. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. INSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail 'A', attached. 5. Nailing shall be in compliance with Detail 'B', attached. LABELING L Shingles shall be labeled with the Miami -Dade Seal as seen below, or the wording "Miami -Dade County Product Control Approved". MIAMI•DADE COUNTY MIAMIOADE COUNTY NOA No.: 16-0425.01 Expiration Date: 07/19/21 Approval Date: 07/21/16 Page 3 of 6 Buu,DING PERMIT REQUIREMENTS 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. DETAIL A MIAWDADE COUNWIE NOA No.:i46-0425.01 Expiration Date: 07/19/21 Approval Date: 07/21/16 Page 4 of 6 DETAIL B DURATION & TRUDEFINITION® DURATION® (SEALANT MAY 13E CONTINUOUS OR DASHED. NOT SHOWN IN THE DETAIL DRAWINGS) D� va mz a a— c g �m MAMMADE COUNTY NOA No.: 16-0425.01 Expiration Date: 07/19/21 Approval Date: 07/21/16 Page 5 of 6 a t`daii pattern F-Sgwma do 6 cb ryas b 51E" sure S Str tit= expostci6n s1l*F" 'a faslenEng we.2 width Ara3 dodavas SuraWja CL-Mvs MAXIMUM SLOPE 21:12 S sm- Fxpowrw% 6 5/8" de eVosac56n Fastening for Slopes Greater Than 21:12 SureNailO fastening area width Nail, Typical 12" I F F, 12" 6.1f8" 5-5/8" eiposme � - , Four V Spots of Asphalt Roofing Cement SLOPE GREATER THAN 21:12 END OF THIS ACCEPTANCE )l MLAMFDADE COUNTY NOA No.: 16-0425.01 Expiration Date: 07/19/21 Approval Date: 07/21/16 Page 6 of 6 MIAMI•E� MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC R ES ) ^ qqq 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DMSIONo Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA)�i M 9 U ' W( www.miamidade.eov/economy GAF FsTIL_4­��Wlw"�, ECEIV 1 Campus Drive SCANNED Parsippany, NJ. 07054 EB 15 Z019 Sk Lucie unty SCOPE: leCoamlCO This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Cobra® Exhaust Vent for Roof Ridge LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 14-1224.18 and consists of pages 1 through 3. The submitted documentation was reviewed by Jorge L. Acebo. NOA No. 18-0619.02 Expiration Date: 11/09/19 Approval Date: 11/15/18 Page 1 of 3 ROOFING COMPONENT APPROVAL Category Roofing Sub -Category: Ventilation Materials: Plastic TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: _ Test -Product Product Dimensions Specification Description GAF Cobra® Exhaust Vent 3/4" x 10 1/2" x 20' TAS-100 Low profile attic ridge vent for installation for Roof Ridge under ridge shingles. GAF Cobra® Exhaust Vent 5/8" x 10 1/2" x 20' TAS-100 Low profile attic ridge vent for installation for Roof Ridge under ridge shingles. (For nail guns) EVIDENCE SUBMITTED: 1. Acworth, GA. EVIDENCE SUBMITTED: Test Agency/Identifier Name Intertek - Architectural Testing TAS 100(A) ASTM D 1929 ASTM D 635 ASTM D 2843 MIAMI-DADE COUNTY F.W. 1 Report Date I3223.01-109-18 06/06/18 13223.02-106-18 RI 07/20/18 13223.02-106-18 RI 07/20/18 I3223.02-106-18 Rl 07/20/18 NOA No. 18-0619.02 Expiration Date: 11/09/19 Approval Date: 11/15/18 Page 2 of 3 APPROVED APPLICATIONS Tradename: GAF Cobra® Exhaust Vent for Roof Ridge System Type: Mechanical attachment of static vent over asphalt shingle roof systems only. Cutout: Cut a 2" slot along the ridge of the roof by cutting 1" on each side of the ridge. Leave uncut sheathing area of 6" at each end of the ridge. Cut through sheathing only, avoiding roof trusses. In buildings with a ridge board, cut 1-3/4" slot on each side. Installation: Roll out ridge vent centered over the slot, and secured 6" o.c. on each side of the ridge with included 2-1/2" corrosion resistant galvanized roofing nails or 1-3/4" collated corrosion resistant galvanized roofing nails (for nail guns) to hold it in place until ridge shingles can be installed. (Polyurethane sealant shall be used to seal the perimeter of the vent to the roof shingles.) Extend to the rake edge. Roll ends or cut joints shall be butted together and caulked with an approved polyurethane sealant. Ridge Shingle: Install pre -manufactured or field -cut ridge shingles over the ridge vent in compliance with the shingle manufacturer's Notice of Acceptance (NOA) and the installation instructions. Ring shank nails shall be corrosion resistant and long enough to penetrate through the wood deck a minimum of 3/16". Apply a bead of polyurethane sealant in between adjacent cap shingles to seal the caps. Net Free Area: Refer to manufacturers published literature. LIMITATIONS: 1. Refer to applicable building codes for required ventilation. 2. This acceptance is for installations over asphalt shingle roof systems only. 3. GAF Cobra® Exhaust Vent for Roof Ridge shall not be installed on roof mean heights greater than 33 feet. 4. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 5. All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state and following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. END OF THIS ACCEPTANCE NOA No. 18-0619.02 Expiration Date: 11/09/19 Approval Date: 11/15/18 Page 3 of 3 MIAMI = �S NNEC mom St.I BY DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) LuC1e COUnty BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) RECEIVED CertainTeed CR555 20 Moores RoaMalvern, PA 1 &T. MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786)315-2590 F (786) 31525-99 w "v.miamidade.eov/economy FEB I5 2019 SCOPE: ----� This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: CertainTeed Modified Bitumen Roofing Systems over Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 17-1003.04 and consists of pages 1 through 49. The submitted documentation was reviewed by Alex Tigera. NOA No.: 18-1127.18 Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 1 of 49 ROOFING SYSTEM APPROVAL Category' Roofing Sub -Category: Modified Bitumen Material: APP/SBS Deck Type: Wood Maximum Design Pressure: -127.5 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Sheet Flexiglas Base Sheet Roll weight: 70 lbs. (2 squares) 39 3/8" x 98'9'; Roll weight: 90 lbs. (3 squares) Test Product II base sheet. ASTM D 4601, Type Modified Bitumen coated fiberglass II base sheet. Flintlastic Base 20 39 3/8' x 49' 6' ; Roll ASTM D 6163, Modified Bitumen coated fiberglass weight: 901bs. Grade S, Type I base sheet. (1.5 squares) int as y 4'3 '.r 39 3{$" x 164'7 $oll ASTM D 2178 �yp�. Fiber lass as halt im re ated plp,shee weight: 381bs. IV (5 squares) UL Type Gl Flintglas Premium Ply 6 eFlintlastic STA Flintlastic GTA 39 3/s" x 164'7'; Roll weight: 40 lbs. (5 squares) 39 3/sn x 32' 10' ; Roll weight: 87 lbs. (1 square) 39 3/8" x 32' 10'; Roll weight: 105 lbs. (1 square) ASTM D 2178, Type Fiberglass, asphalt impregnated ply VI sheet. UL Type GI ASTM D 6222, Smooth surfaced APP Modified Grade S, Type I Bitumen membrane with non -woven polyester mat reinforcement for torch application. ASTM D 6222, Granule surfaced APP Modified Grade G, Type I Bitumen membrane with non -woven polyester mat reinforcement for torch application. Flintlastic GTA-FR 39 3/8' x 32' 10' ; Roll ASTM D 6222, Granule surfaced APP Modified weight: 105 lbs. Grade G, Type I Bitumen membrane with non -woven (1 square) polyester mat reinforcement for torch application. NOA No.: 18-1127.18 Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 2 of 49 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description Flintlastic FR-P 39'/8" x 32' 10"; Roll ASTM D 6164, Fire resistant, granule surfaced SBS weight: 101 lbs. Grade G, Type I Modified Bitumen Membrane with - - —(I-square) -- — - - non -woven -polyester mat reinforcement for mop application. Flintlastic Premium FR-P 39'/8" x 32' 10'; Roll ASTM D 6164, Fire resistant, granule surfaced SBS weight: 101 lbs. Grade G, Type H Modified Bitumen Membrane with (1 square) non -woven polyester mat reinforcement for mop application. Flintlastic FR Dual Cap 39'/8" x 32' 10' ; Roll ASTM D 6162, Granule surfaced SBS modified weight: 103 lbs. Grade G, Type II bitumen membrane with a nonwoven (1 square) polyester/fiberglass composite mat reinforcement for use in cold or mop applications. Flintlastic Cap 30 39 3/8' x 32' 10' ; Roll ASTM D 6163, Granule surfaced SBS Modified weight: 86 lbs. Grade G, Type I Bitumen membrane with fiberglass mat (I square) reinforcement for mop applications. Flintlastic FR Cap 30 39 3/8' x 32' 10'; Roll ASTM D 6163, Fire resistant, granule surfaced SBS weight: 86 lbs. Grade G, Type I Modified Bitumen membrane with (1 square) fiberglass mat reinforcement for mop applications. Flintlastic FR Cap 30 T 39-3/8" x 32' 10"; Roll ASTM D 6163, Granule surfaced SBS Modified weight: 100 lbs. Grade G, Type I Bitumen membrane with fiberglass (1 square) mat reinforcement for torch application. Flintlastic Base 20 T 39-3/8" x 33'; Roll ASTM D 6163, Modified Bitumen, coated fiberglass Weight: 81 lbs. Grade S, Type I base sheet for torch application. (1 square) Flintlastic Ultra Poly SMS 39'/a" x 32' 10'; Roll ASTM D 6164, Smooth surfaced SBS Modified Base Sheet weight: 90 lbs. (1 Grade S, Type I Bitumen Membrane with non -woven squares) polyester mat reinforcement for mop or torched applications. Glasbase Base Sheet 36" x 98' 9'; Roll ASTM D 4601, Type Asphalt coated, fiberglass base sheet. weight: 75 lbs. II (3 squares) Flintlastic Poly SMS Base 39'/8" x 64' 3' ; Roll ASTM D 4601, Modified Bitumen coated polyester Sheet weight: 90 lbs. Grade S, Type II base sheet. (2 squares) NOA No.: 18-1127.18 Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 3 of 49 i TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description Yosemite Venting Base Sheet 39 3/8" x 32' 10'; Roll ASTM D 3909 Mineral Surfaced fiberglass reinforced weight: 85 tbs. ASTM D 4897, Type buffer sheet. Flintlastic APP Base T 39 3/s" x 65' 4'; Roll weight: 1001bs. (2 squares) Flintlastic Ultra Glass SA 39 3/8" x 33' 11' ; Roll weight: 73 tbs. (1 square) Black DiamondTM Base Sheet 36" x 68'7' ; Roll weight: 78 lbs. (2 squares) Flintlastic SA P1yBase 39 3/8" x 66'6"; Roll weight: 861bs. (2 squares) Flintlastic SA Mid Ply F1intBond Brush 39 3/8" x 32' 1"; Roll weight: 621bs. (1 square) 5 gallon pails UL Type G3 ASTM D 6509 Modified Bitumen coated fiberglass base sheet. ASTM D 1970 Self -adhering, fiberglass reinforced, SBS modified bitumen base/ply sheet. ASTM D 1970 Self -adhering fiberglass reinforced ASTM D4601 Type I modified bitumen base sheet ASTM D 4601, Self -adhering, fiberglass reinforced, Grade S, Type ll I SBS modified bitumen base/ply sheet. ASTM D 1970 ASTM D 6163, Self -adhering, polyester reinforced, Grade S, Type 1 SBS modified bitumen ply sheet. ASTM D 3019 Cold applied, SBS polymer modified asphalt adhesive. NOA No.: 18-1127.18 Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 4 of 49 1 APPROVED INSULATIONS: Product Name . TABLE2 Product Description FlintBoard ISO Polyisocyanurate foam insulation FlintBoardx ISO Polyisocyanurate foam insulation_ F1intBoard ISO Cold Polyisocyanurate foam insulation ACFoam-II Polyisocyanurate foam insulation ACFoam-III Polyisocyanurate foam insulation DensDeck Water resistant gypsum board DensDeck Prime Water resistant gypsum board H-Shield Polyisocyanurate foam insulation ENRGY 3 Polyisocyanurate foam insulation ENRGY 3 25 PSI Polyisocyanurate foam insulation Multi -Max FA-3 Polyisocyanurate foam insulation SECUROCK Gypsum -Fiber Roof Board homogenous fiber reinforced Structodek High Density Fiberboard High Density Wood Fiber Insulation Roof Insulation board FescoBoard Expanded perlite and fiber insulation Manufacturer (With Current NON) CertainTeed Corp. CertainTeed Corp._ CertainTeed Corp. Atlas Roofing Corp. Atlas Roofing Corp. Georgia Pacific Gypsum LLC Georgia Pacific Gypsum LLC Hunter Panels LLC Johns Manville Corp. Johns Manville Corp. RMax Operating, LLC USG Corp. Blue Ridge Fiberboard, Inc. Johns Manville Corp. NOA No.: 18-1127.18 Expiration Date: 06/1923 Approval Date: 01/17/19 Page 5 of 49 APPROVED FASTENERS/ADHESIVES: Fastener Product Number Name 1. Trufast #12 DP Fastener 2. Trufast 3" Metal Insulation Plate 3. F1intFast 912 4. FlintFast 3" Insulation Plate 5. F1intFast #14 6. 7. 8. 9. 10. 11. 12. 13. 14. Simplex MAXX Cap #12 Standard Roofgrip OMG 3" Galvalume Steel Plate Trufast #14 HD Fastener OMG Heavy Duty 3 in. Round Metal Plate AccuTrac Hextra AccuTrac Plate AccuTrac Flat Bottom Plate Millennium One Step Foamable Adhesive Millennium One Step Green Foamable Adhesive Millennium PG-1 Low Viscosity Insulation Adhesive Insta Stik Quik Set Insulation TABLE 3 Product Description Insulation fastener for wood and steel decks Galvalume steel plate Coated, carbon steel screw Galvalume AZ50 steel plate Insulation fastener for wood and steel decks Polymer fastner Insulation fastener for wood and steel. Galvalume stress plate Insulation fastener for wood and steel decks Insulation and membrane fastener Galvalume AZ50 steel plate Carbon steel fastener Galvalume stress plate. A2-SS aluminized steel plate Polyurethane two component high rise insulation adhesive Polyurethane two component high rise insulation adhesive Polyurethane two component low rise insulation adhesive Polyurethane one component moisture curing adhesive Manufacturer Dimensions (With Current NOA) various Altenloh, Brinch & Co. U.S., Inc. 3" round Altenloh, Brinch & Co. U.S., Inc. various CertainTeed Corp. 3" round CertainTeed Corp. various CertainTeed Corp. I" long Simplex Nails, Inc. various OMG, Inc. 3" round OMG, Inc. various Altenloh, Brinch & Co. U.S., Inc. Various OMG, Inc. 3" round OMG, Inc. Various OMG, Inc. 3" square OMG, Inc. 3" square OMG, Inc. 1.5 liters H.B. Fuller Company 1.5 liters H.B. Fuller Company 1.5 liters H.B. Fuller Company It is supplied The Dow Chemical Company in pressurized cylinders with a net weight of 23 lbs., with a total unit weight of 30 lbs. NOA No.: 18-1127.18 Expiration Date: 06/19/23 Approval Date: O1/17/19 Page 6 of 49 t APPROVED FASTENERS/ADHESIVES: Fastener Product Number Name 19. OMG OlyBond 500 Adhesive 20. OMG OlyBond 500 Green Adhesive TABLE 3 Product Description Spray polyurethane foam insulation adhesive Spray polyurethane foam insulation adhesive Dimensions 10 gal. bag -in - box set and SpotShot cartridge 10 gal. bag -in - box set and 1.5 liters SpotShot cartridge Manufacturer (With Current NOA) OMG, Inc. OMG, Inc. APPROVED SURFACING/COATING OPTIONS: TABLE 4 Chosen components must be applied according to manufacturer's application instructions. Any coating, listed below, used as a surfacing, must be listed within a current NOA. System Number Manufacturer Application 1. Generic Gravel applied at 400 lbs/sq., adhered with flood coat of asphalt at 60 lbs/sq. 2. Generic Slag applied at 300 lbs/sq., adhered with flood coat of asphalt at 60 lbs/sq. 3. Karnak Corp. Karnak (#97 AF) Fibrated Aluminum Roof Coating applied at an application rate of 1.5 gal/sq. 4. CertainTeed Corp. F1intCoat A-150 applied at an application rate of 1.5 gal/sq. 5. Gardner Asphalt Corp. APOC #212 Fibered Aluminum Roof Coating applied at an application rate of 1.5 gal/sq. 6. Gardner Asphalt Corp. APOC #400 Sunbrite applied at an application rate of 3 gal./sq. NOA No.: 18-1127.18 Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 7 of 49 v EVIDENCE SUBMITTED: Test Agency/Identifer Name Report Date Factory Mutual Research Corp. FM 4470 3Y8A1.AM 03/23/96 FM 4470 OD3A3.AM 04/04/97 FM 4470 1D7A4.AM 11/09/98 FM 4470 2DOAO.AM 12/23/98 -- FM 4470 3024311 11101-106 FM 4470 3031350 09/27/07 FM 4470 3036182 07/31/09 FM 4470 3039046 06/15/10 FM 4470 3048520 09/19/13 Underwriters Laboratories, Inc. UL 790 R11656 01/11/13 United States Testing Company ASTM D 5147 97-457-2R 12/02/87 ASTM D 5147 97-4574 06/03/88 Momentum Technologies, Inc. ASTM D 6164 AX31G8F 06/05/09 TrinitylERD TAS 114 (J) 3507.08.99-1 04/18/01 TAS 114 (J) 3504.06.01-1 06/05/01 TAS 114 3521.07.04 07/29/04 TAS 114 3533.01.06 01/06/06 TAS 114 (H) Letter 04/05/06 TAS 117 (B) 3503.10.06 10/10/06 TAS 117 (13) 06490.04.07-R1 06/27/07 TAS 117 (B) / ASTM D 6862 C8500SC.11.07 11/30/07 FM 4470, TAS 114, FM 4470, C8370.08.08-R1 10/05/09 TAS 114 (J) TAS 114 (H), TAS 117 (B), TAS C30560.06.10 06/10/10 114 (J) FM 4470, TAS 114 C32830.07.10 07/20/10 ASTM D 6164 / D 4798 C31410.01.11-2 01/10/11 TAS 117 B C35500.02.11 02/09/11 FM 4470 (K) / TAS 114 (J) 03515.07.03-1-R1 06/27/12 ASTM D 1876, TAS 114 (14), C42110.08.12 08/13/12 TAS 117 (B) FM 4474 / TAS 114 C39670.08.12 08/20/12 ASTM D 4601 C40050.09.12-1 09/28/12 ASTM D 1970 C40050.09.12-2 09/28/12 ASTM D 5147 / D 4798 C31410.10.10-R1 11/O1/12 ASTM D 5147 / D 4798 C31410.01.11-1-R1 11/O1/12 ASTM D 4798 C31410.01.11-2A-Rl 02/21/13 ASTM D 4798 C31410.12.13 12/05/13 ASTM D 6222 C40050.12.13-R1 12/31/13 TAS 117, TAS 114 C30310.12.09-R1 03/07/14 ASTM D 2178 C47250.03.14 03/26/14 ASTM D 1876, TAS 114 (H), C45620.03.14 03/27/14 FM 4474 NOA No.: 18-1127.18 Expiration Date: 06/19/23 Approval Date: O1/17119 Page 8 of 49 EVIDENCE SUBMITTED: Test Agency/Identifier Name Report Date ASTM D4601 CTR-SC8740.04.15-R2 04/21/15 ASTM D 1876, TAS 114 (H), C47320.03.14-R1 04/O1/15 FM 4474 ASTM D 1876 C35460.05.11-R1 05/20/15 FM-4474-(D) /-UL 1897_/ TAS -CT-R-SC10420.01.16- - 01/25/16 114 (J) FM 4474 / TAS 114 (J) CTR-SC9175.0916-2 09/06/16 FM 4470 (K) / UL 1897 / TAS CTR-SC11590.08.16- 09/06/16 114 (J) RI ASTM D 4601-04 (2012), Type lI CTR-SC11145.09.16- 09/19/16 3C ASTM D 4601-04 (2012), Type II CTR-SCI 1145.09.16- 09/19/16 3A ASTM D 6163 CTR-SC11145.09.16- 09/19/16 5A ASTM D 6222 CTR-SC11145.09.16- 09/19/16 7A PRI Construction Materials ASTM D 6163 CTC-056-02-01 08/25/10 Technologies LLC ASTM D 6163 CTC-066-02-01 08/09/11 ASTM D 6222 CTC-071-02-01 08/08/11 ASTM D 6164 / D 4798 CTC-093-02-01 08/09/11 ASTM D 4601 CTC-126-02-01 03/12/12 ASTM D 2178 CTC-123-02-01 03/13/12 ASTM D 4601 CTC-127-02-01 03/13/12 ASTM D 6163 CTC-128-02-01 06/11/12 ASTM D 6163 CTC-129-02-01 06/11/12 ASTM D 6164 CTC-132-02-01 06/11/12 ASTM D 6164 CTC-161-02-01 05/09/13 ASTM D 6162 CTC-183-02-01 10/02/13 ASTM D 6164 CTC-190-02-01 12/02/13 ASTM D 1970 CTC-199-02-01 01/22/14 ASTM D 6163 CTC 319-02-01 08/22/17 NOA No.: 18-1127.18 Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 9 of 49 APPROVED ASSEMBLIES: Membrane Type: APP Modified Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 6" o.c. at wood joists spaced maximum 24" o.c. System Type-A(1):—Anchor-sheet-mechanically-fastened, all layers -of -insulation adhered -with -approved -asphalt. All General and System Limitations apply. Anchor Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet or Flintglas Premium Ply 6 mechanically attached as detailed below. Fastening: Anchor sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c. One or more layers of any of the following insulations. Insulation Laver Insulation Fasteners Fastener able 3 Density/ft2 ACFoam-11, ACFoam-III, F1intBoard ISO, FlintBoard ISO Cold, Multi -Max FA-3, ENRGY 3,13-Shield, FlintBoarda ISO Minimum 1.5" thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ff. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Base Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered to the insulated substrate. Ply Sheet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS, Glasbase Base Sheet, (Optional) Flexiglas Base Sheet, Flintlastic Base 20 or Flintlastic Poly SMS Base or one or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to the base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or Flintlastic STA or Flintlastic APP Base T torch adhered. Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR- P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base or ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR Cap 30 T torch adhered. Or One ply of Flintlastic GTA or Flintlastic GTA-FR torch adhered to base or ply sheet. NOA No.:,18-1127.18 Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 10 of 49 Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -52.5 psf (See General Limitation #7) Pressure: NOA No.: 18-1127.18 MIAM4nAn, COUNTY Expiration Date: 06/1923 Approval Date: O1/17/19 Page 11 of 49 Membrane Type: SBS Modified Deck Type 1I: Wood, Insulated Deck Description: i9/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 6" o.c. at wood joists spaced maximum 24" o.c. System Type A(2): Anchor sheet mechanically fastened; all layers of insulation adhered with approved asphalt. All General and System Limitations apply. Anchor Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet or Flintglas Premium Ply 6 mechanically attached as detailed below. Fastening: Anchor sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c. One or more layers of any of the following insulations. Insulation Laver Insulation Fasteners Fastener Table 3 ' Density/ftx ACFoam-II, ACFoam-III, FlintBoard ISO, FlintBoard ISO Cold, ENRGY 3, ENRGY 3 25 PSI, H-Shield, FlintBoarda ISO Minimum 1.5" thick N/A N/A FescoBoard Minimum %" thick N/A N/A Structodek High Density Fiberboard Roof Insulation Minimum''/2" thick N/A N/A DensDeck, DensDeck Prime Minimum''/," thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ftz. Please refer to Roofing Application Standard PAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Base Sheet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet adhered to the insulated substrate in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq NOA No.: 18-1127.18 MAMFDADE COUNTY ... � � Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 12 of 49 Ply Sheet: One ply of All Weather/Empire Base Sheet, Glasbase Base Sheet, Flexiglas Base Sheet, (Optional) Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or one or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq. or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or Flintlastic Ultra Poly SMS Base Sheet torch applied. Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base/ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR Cap 30 T torch adhered to base or ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -52.5 psf (See General Limitation #7) Pressure: NOA No.: 18-1127.IS Expiration Date: 06/19/23 Approval Date: O1/17/19 Page 13 of 49 Membrane Type: APP Modified Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 6" o.c. at wood joists spaced maximum 24" o. c. System Type A(3): Anchor sheet mechanically fastened; all layers of insulation adhered with approved asphalt. All -General and -System Limitations apply. Anchor Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet, Flintglas Premium Ply 6 mechanically attached as detailed below. Fastening: Anchor sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c. One or more layers of any of the following insulations. Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft2 ACFoam-H, ACFoam-HI, FlintBoard ISO, FlintBoard ISO Cold, Multi -Max FA-3, ENRGY 3, H-Shield, FlintBoardn ISO Minimum 1.5" thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 2040 lbs./100 fe. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Base Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered to the insulated substrate. Ply Sheet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase (Optional) Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20 or Flintlastic Poly SMS Base, Sheet or one or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to the base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq. or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or Flintlastic STA or Flintlastic APP Base T torch adhered. Membrane: Flintlastic GTA or Flintlastic GTA-FR torch adhered to base or ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -60 psf. (See General Limitation /t7) Pressure: NOA No.: 18-1127.18 Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 14 of 49 Membrane Type: SBS Modified Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 6" o.c. at wood joists spaced maximum 24" o. c. System Type A(4): Anchor sheet mechanically fastened; all layer of insulation adhered with approved asphalt. All -General and -System Limitations apply. - Anchor Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet or Flintglas Premium Ply 6 mechanically attached as detailed below. Fastening: Anchor sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c. One or more layers of any of the following insulations. Insulation Laver Insulation Fasteners Fastener Table 3 Density/ff ACFoam-H, ACFoam-III, FlintBoard ISO, FlintBoard ISO Cold, ENRGY 3, ENRGY 3 25 PSI, H-Shield, FlintBoardn ISO Minimum 1.5" thick N/A N/A FescoBoard Minimum'/<" thick N/A N/A Structodek High Density Fiberboard Roof Insulation Minimum''/z" thick N/A N/A DensDeck, DensDeck Prime Minim am %" thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-401bs./100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Base Sheet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet adhered to the insulated substrate in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. NOA No.: 18-1127.18 Expiration Date: 06/19/23 Approval Date: O1/17/19 Page 15 of 49 Ply Sheet: One ply of All Weather/Empire Base Sheet, Glasbase Base Sheet, Flexiglas Base Sheet, (Optional) Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or one or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to the base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq. or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or Flintlastic Ultra Poly SMS Base Sheet torch applied. Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR- P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base or ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR Cap 30 T torch adhered to base/ply sheet. Surfacing: Any of the approved sw facing/coating options listed in Table 4. (Optional) Maximum Design . -60 ps£ (See General Limitation #7) Pressure: NOA No.: 15-1127.18 Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 16 of 49 Membrane Type: APP Modified Deck Type 1I: Wood, Insulated Deck Description: 15/32" or greater CDX plywood or wood plan attached with #8 screws spaced 6" o.c. at wood joists spaced maximum 24" o.c. System Type B(1): Base layer of insulation mechanically fastened, top layer adhered with approved adhesive. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft' ACFoam-II, ACFoam-HI, FlintBoard ISO, FlintBoard ISO Cold, H-Shield, FlintBoarda ISO Minimum 1.5" thick 1,3 1:1.33 ftz Note: Base layer shall be mechanically attached with fasteners and density described above. Insulation panels Hated are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be increased maintaining the same fastener density (See Roofing Application Standard RAS 117 for fastening details). Too Insulation Laver Insulation Fasteners Fastener able 3 Density/ft2 ACFoam-H, ACFoam-III, FlintBoard ISO, FlintBoard ISO Cold, H-Shield, FlintBoarda ISO Minimum 1.5" thick N/A N/A Note: Top layer of insulation shall be adhered with Millennium One Step Foamable Adhesive, Millennium One Step Green Foamable Adhesive, Millennium PG-1 Low Viscosity Insulation Adhesive in 3/4" — 1" wide beads spaced 12 inch o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA, self -adhered to the insulated substrate. Ply Sheet: One or more plies of Flintlastic APP Base T or Flintlastic STA, torch adhered to the base sheet. Membrane: One ply of Flintlastic GTA or Flintlastic GTA-FR torch adhered to the ply sheet. Surfacing: Any of theapproved surfacing/coating options listed in Table 4. (Optional) Maximum Design -67.5 psf (See General Limitation #7) Pressure: NOA No.: 18-1127.18 Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 17 of 49 Membrane Type: APP Modified Deck Type 1I: Wood, Insulated Deck Description: 15/32" or greater CDX plywood or wood plank attached with #8 screws spaced 6" o.c. at wood joists spaced maximum 24" o.c. System Type B(2): Base layer of insulation mechanically fastened, top layer adhered with approved All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Laver Insulation Fasteners Fastener able 3 Density/ft' ACFoam-H, ACFoam-III, F1intBoard ISO, FlintBoard ISO Cold, H-Shield, FlintBoarda ISO Minimum 1.5" thick 1,3 1:1.33 fe Note: Base layer shall be mechanically attached with fasteners and density described above. Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be increased maintaining the same fastener density (See Roofing Application Standard RAS 117 for fastening details). Top Insulation Laver SECUROCK Gypsum -Fiber Roof Board Minimum'/4" thick Insulation Fasteners Fastener able 3 Density/W N/A N/A Note: Top layer of insulation shall be adhered with Millennium One Step Foamable Adhesive, Millennium One Step Green Foamable Adhesive, Millennium PG-1 Low Viscosity Insulation Adhesive, Insta-Stik Quik Set Insulation Adhesive, OMG OlyBond 500 Adhesive or OMG OlyBond 500 Green Adhesive in 3/4" — 1" wide beads spaced 12 inch o.c. Please refer to Rooting Application Standard RAS 117 for insulation attachment. Base Sheet: One ply of Flintlastic STA or Flintlastic APP Base T, torch adhered to the insulated substrate. Ply Sheet: One ply of Flintlastic STA or Flintlastic APP Base T, torch adhered to the base sheet. (Optional) Membrane: One ply of Flintlastic GTA or Flintlastic GTA-FR, torch adhered to base or ply sheet. Surfacing: Any of the approved surfacingicoating options listed in Table 4. (Optional) Maximum Design -90 psf (See General Limitation #7) Pressure: MIAMFDADECOUN7Y ...ll NOA No.: 18-1127.18 Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 18 of 49 Membrane Type: SBS/APP Modified Deck Type 1I: Wood, Insulated Deck Description: 15/32" or greater APA rated CDX plywood or wood plank attached with 8d ring shank nails spaced 6" o.c. at wood joists spaced maximum 24" o.c. System Type C(1): All layers of insulation simultaneously attached. All -General -and -System -Limitations -apply. One or more layers of any of the following insulations. Base Insulation Laver (Optional) Insulation Fasteners Table 3 ACFoam-II, ACFoam-III, FlintBoard ISO, FlintBoard ISO Cold Minimum 1.5" thick N/A Note: All layers shall be simultaneously fastened; see top -layer below for fasteners and density. Too Insulation Laver Insulation Fasteners Table 3 ACFoam-II, ACFoam-III, FlintBoard ISO, FlintBoard ISO Cold Minimum 1.5" thick 2 with 9 or 4 with 5 Fastener Density/fe N/A Fastener Density/ft2 1:1.6 ft2 Note: Top insulation layer shall be mechanically attached using the fastener density listed above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Insulation fasteners shall be tested for withdrawal resistance in compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load requirements. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Primer: FlintPrime primer applied at a rate of 0.5 gal/sq and allowed to dry prior to application of base sheet. *Required only for Flintlastic SA PlyBase or Flintlastic SA Mid Ply. Base Sheet: One ply of Flintlastic SA PlyBase or Flintlastic SA Mid Ply, self -adhered to the insulated substrate. *Requires use of self -adhering sheet overtop. Or One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA, torch applied to the insulated substrate. *Requires use of torch -applied sheet overtop. Ply Sheet: One ply of Flintlastic SA P1yBase or Flintlastic SA Mid Ply, self -adhered to the base sheet. (Optional) *Requires use of self -adhering sheet overtop. Or One ply of Flintlastic Ultra Poly SMS Base Sheet, Flintlastic Base 20 T, Flintlastic APP Base T or Flintlastic STA torch adhered to the base sheet. *Requires use of torch -applied sheet overtop. NOA No.: 18-1127.18 Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 19 of 49 Membrane: Flintlastic FR Cap 30 T, Flintlastic GTA or Flintlastic GTA+R torch adhered to base or ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) -Maximum Design52.5_psf(See-General-Limitation47) Pressure: NOA No.: 18-1127.18 Expiration Date: 06/19/23 Approval Date: O1/17/19 Page 20 of 49 Membrane Type: APP Modified Deck Type 1I: Wood, Insulated Deck Description: 15132" or greater CDX plywood or wood plank attached with #8 screws spaced 6" o.c. at wood joists spaced maximum 24" o.c. System Type C(2): All layers of insulation simultaneously attached. All -General -and System -Limitations app . One or more layers of any of the following insulations. Base Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft2 ACFoam-II, ACFoam-HI, FlintBoard ISO, FlintBoard ISO Cold, H-Shield, FlintBoardu ISO Minimum 1.5" thick N/A N/A Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Too Insulation Laver Insulation Fasteners Fastener able 3 Density/ff SECUROCK Gypsum -Fiber Roof Board Minimum 1/4' thick 1,3 1:1.33 ftz Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Insulation fasteners shall be tested for withdrawal resistance in compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load requirements. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: One ply of Flintlastic STA or Flintlastic APP Base T, torch adhered to the insulated substrate. Ply Sheet: One ply of Flintlastic STA or Flintlastic APP Base T, torch adhered to the base sheet. (Optional) Membrane: One ply of Flintlastic GTA or Flintlastic GTA-FP, torch adhered to base or ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -67.5 psf (See General Limitation #7) Pressure: NOA No.: 18-1127.18 MIAMMADE COUNTY - , Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 21 of 49 Membrane Type: APP Modified Deck Type 1I: Wood, huulated Deck Description: 15/32' or greater CDX plywood or wood plank attached with #8 screws spaced 6" o.c. at wood joists spaced maximum 24" o.c. System Type C(3): All layers of insulation simultaneously attached. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft' ACFoam-II, ACFoam-III, FlintBoard ISO, FlintBoard ISO Cold, H-Shield, FlintBoardn ISO Minimum 1.5" thick N/A N/A Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Ton Insulation Laver Insulation Fasteners Fastener Table 3 Density/fe ACFoam-Il, ACFoam-HI, FlintBoard ISO, FlintBoard ISO Cold, H-Shield, FlintBoardn ISO Minimum 1.5" thick 1, 3 1:1.33 fe Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Insulation fasteners shall be tested for withdrawal resistance in compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load requirements. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA, self -adhered to the insulated substrate. Ply Sheet: One or more plies of Flintlastic APP Base T or Flintlastic STA, torch adhered to the base sheet. Membrane: One ply of Flintlastic GTA or Flintlastic GTA-FR torch adhered to ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -75.0 psf (See General Limitation #7) Pressure: NOA No.: 18-1127.18 MIAMI-DADECOUNTY • .. � � Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 22 of 49 Membrane Type: SBS Modified Deck Type 1I: Wood, Insulated Deck Description: 15/32" or greater APA rated CDX plywood or wood plank attached with 8d ring shank nails spaced 6" o.c. at wood joists spaced maximum 24" o.c. System Type D(1): All layers of insulation and base sheet simultaneously attached. —All General and System Limitations apply. One or more layers of any of the following insulations. Insulation Laver Any Approved Polyisocyanurate Listed in Table 2 Minimum 1.5" thick Insulation Fasteners Fastener Table 3 Densitv/fe N/A N/A Note: Insulation layer shall have preliminary attachment, prior to the installation of the base sheet, at an application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and four fasteners for any insulation board having no dimension greater than 8 ft. All layers of insulation and base sheet shall be simultaneously fastened. See base sheet below for fasteners and density. Base Sheet: One ply of Glasbase Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Yosemite Venting Base Sheet, Flintlastic Poly SMS Base Sheet and Flintlastic Ultra Poly SMS Base Sheet, mechanically attached as described below. Fastening #1: Trufast #12 DP Fasteners or Trufast #14 HD Fasteners with Trufast 3" Metal Insulation Plates, F1intFast #12 fasteners or F1intFast #14 fasteners with F1intFast 3" Insulation Plates spaced 8" o.c, at the 4" wide laps and 8" o.c. in three, equally spaced staggered center rows. Ply Sheet: One ply of Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly (Optional) SMS Base Sheet applied in FlintBond Brush at a rate of 1.0 — 1.5 gal/sq to the base sheet. Membrane: One ply of Flintlastic Cap 30, Flintlastic FR Cap 30, Flintlastic FR Dual Cap, Flintlastic FR- P, Flintlastic Premium FR-P or Flintlastic GMS applied in FlintBond Brush at a rate of 1.0 — 1.5 gal/sq to base or ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -52.5 psf (See General Limitation #7) Pressure: NOA No.: 18-1127.18 Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 23 of 49 Membrane Type: Deck Type 1I: Deck Description: System Type D(2): SBS Modified Wood, Insulated 15/32" or greater APA rated plywood or wood plank attached with #10 wood screws spaced 6" o.c. at wood joists spaced maximum 24" o.c. All layers of insulation and base sheet simultaneously attached. All General and System Limitations apply. One or more layers of any of the following insulations. Insulation Laver Any Approved Polyisocyanurate Listed in Table 2 Minimum 1.5" thick Insulation Fasteners Fastener able 3 Density/ftz N/A N/A Note: Insulation layer shall have preliminary attachment, prior to the installation of the base sheet, at an application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and four fasteners for any insulation board having no dimension greater than 8 ft. All layers of insulation and base sheet shall be simultaneously fastened. See base sheet below for fasteners and density. Base Sheet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet, mechanically attached as described below. Fastening #1: Fastened with Trufast #14 HD Fasteners with Trufast 3" Metal Insulation Plates or F1intFast #14 Fasteners with FlintFast 3" Insulation Plates spaced 8" o.c. at the 4" wide laps and 8" o.c. in three, equally spaced staggered center rows. Ply Sheet One ply of Glasbase Base Sheet, All Weather/Empire Base Sheet, Flexiglas Base Sheet, (Optional): Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet adhered to base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq. or one ply of Glasbase Base Sheet, All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Base 20 T or Flintlastic Ultra Poly SMS Base torch applied to base sheet or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered to the base sheet. Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR- P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base or ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or one ply of Flintlastic FR Cap 30 T torch adhered to base or ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -97.5 psf. (See General Limitation #7) Pressure: NOA No.: 18-1127.18 Expiration Date: 06/1923 Approval Date: 01/17/19 Page 24 of 49 Membrane Type: SBS Modified Deck Type 1: Wood, Non -insulated Deck Description: 15/32' or greater CDX plywood or wood plank attached with 8d ring shank nails spaced 6" o.c at wood joists spaced maximum 24" o.c. System Type E(1): Base sheet mechanically fastened. All -General and System -Limitations apply. - - Base Sheet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, All Weather / Empire Base Sheet, Flintlastic Base 20 or Flintlastic Poly SMS Base Sheet mechanically attached as detailed below. Fastening #1: Fastened with Simplex MAXX Cap fasteners spaced 9" o.c. in the 2" side lap and 12" o.c. in two evenly divided, staggered rows in the center of the sheet. Membrane: One ply of Flintlastic Cap 30, Flintlastic FR Cap 30, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-P or Flintlastic GMS adhered to the base sheet with approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs/sq. or one ply of Flintlastic FR Cap 30 T,torch-applied to base sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -52.5 psf (See General Limitation #9) Pressure: NOA No.: 18-1127.18 Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 25 of 49 Membrane Type: APP Modified Deck Type 1: Wood, Non -insulated Deck Description: 15/32 " or greater CDX plywood or wood plank attached with 8d ring shank nails spaced 6" o.c. at wood joists spaced maximum 24" o.c. System Type E(2): Base sheet mechanically fastened. AllGme—ral a�ltn -System Limitations apply. Base Sheet: One ply of Flintlastic APP Base T mechanically attached as detailed below. Fastening #1: Fastened with Simplex MAXX Cap fasteners spaced 9" o.c. in the 2" side lap and 12" o.c. in two evenly divided, staggered rows in the center of the sheet. Membrane: One ply of Flintlastic FR Cap 30, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-P or Flintlastic GMS adhered to the base sheet with approved mopping asphalt applied within the EVT range and at a rate of 2040 lbs/sq. or one ply of Flintlastic FR Cap 30 T, torch - applied to base sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -52.5 psf (See General Limitation #9) Pressure: NOA No.: 18-1127.18 Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 26 of 49 Membrane Type: APP Modified Deck Type 1: Wood, Non -Insulated Deck Description: 19/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 6" o.c. at wood joists spaced maximum 24" o.c. System Type E(3): Base sheet mechanically fastened. All General and System Limitations apply. Base Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet or Flintglas Premium Ply 6 mechanically attached as detailed below. Fastening #1: Base sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c. Ply Sheet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase (Optional) Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or one or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to the base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq. or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or Flintlastic STA or Flintlastic APP Base T torch adhered. Membrane: Flintlastic GTA or Flintlastic GTA-FR torch adhered to base or ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -52.5 psf. (See General Limitation #7) Pressure: NOA No.: 18-1127.18 Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 27 of 49 F embiane', vL3en , S Modied� rDeckTq j;. %354d,Nondmulated-� Deck Description: 19/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 6" o.c. at wood joists spaced maximum 24" o.c. System Type E(4): Base sheet mechanically fastened, All General -and System Limitations apply. Base Sheet: - One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet or Flintglas Premium Ply 6 mechanically attached as detailed below. Fastening #1: Base sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c. Ply Sheet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase (Optional) Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or one or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to the base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of20-40 lbs./sq. or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or Flintlastic Ultra Poly SMS Base Sheet torch adhered. Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR- P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base or ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR Cap 30 T torch adhered to base or ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -52.5 psf. (See General Limitation #7) Pressure: A No�8=1127.18 Expir lion��D..a,te D6 9/23 ApprovarD [ wig Page:2� 49 Membrane Type: SBS Modified Deck Type 1: Wood, Non -Insulated Deck Description: 15/32" or greater CDX plywood or wood plank attached with #8d ring shank nails spaced 6" o.c. at wood joists spaced 24" o.c. System Type E(5): Base sheet mechanically fastened. All General dud -System Limitations apply. Base Sheet: One ply of Glasbase Base Sheet or Yosemite Venting Base Sheet, mechanically attached as described below. Fastening #1: Fastened with FBC HVHZ nails and tin caps spaced 6" o.c. at the 3" lap and 6" o.c. in four, equally spaced staggered center rows. Ply Sheet: One or more plies of Glasbase Base Sheet, All Weather/Empire Base Sheet, Flexiglas Base (Optional) Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet adhered to the base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one or more plies of Flintlastic Base 20 T or Flintlastic Ultra Poly SMS Base Sheet, torch applied. Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR- P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base or ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or one ply of Flintlastic FR Cap 30 T torch adhered to base or ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -52.5 psf. (See General Limitation #7) Pressure: NOA No.: 18-1127.18 Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 29 of 49 Membrane Type: SBS Modified Deck Type 1: Wood, Non -Insulated Deck Description: 15/32" or greater APA rated CDX plywood or wood plank attached with 8d ring shank nails spaced 6" o.c. at wood joists spaced maximum 24" o.c. System Type E(6): Base sheet mechanically fastened All General and System Limitations apply. Base Sheet: One ply of Glasbase Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Yosemite Venting Base, Flintlastic Poly SMS Base and Flintlastic Ultra Poly SMS Base, mechanically attached as described below. Fastening #1: Trufast #12 DP Fasteners or Trufast #14 HD Fasteners with Trufast 3" Metal Insulation Plates, F1intFast #12 fasteners or F1intFast #14 fasteners with F1intFast 3" Insulation Plates spaced 8" o.c. at the 4" wide laps and 8" o.c. in three, equally spaced staggered center rows. Ply Sheet One ply of Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS (Optional): Base Sheet applied in FlintBond Brush at a rate of 1.0 — 1.5 gal/sq. to the base sheet. Membrane: One ply of Flintlastic Cap 30, Flintlastic FR Cap 30, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-P or Flintlastic GMS applied in F1imBond Brush at a rate of 1.0 — 1.5 gal/sq to base or ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -52.5 psf. (See General Limitation #7) Pressure: NOA No.: 18-1127.18 Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 30 of 49 Membrane Type: Deck Type 1: Deck Description: APP Modified Wood, Non -Insulated 19/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 4" o.c. at wood joists spaced maximum 24" o.c. System Type E(7): Base sheet mechanically fastened. All General and System Limitations apply. Base Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet or Flintglas Premium Ply 6 mechanically attached as detailed below. Fastening #1: Base sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c. Ply Sheet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase (Optional) Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or one or more Flintglas Ply 4 or Flintlgas Premium Ply 6 adhered to the base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or Flintlastic STA or Flintlastic APP Base T torch adhered. Membrane: Flintlastic GTA or Flintlastic GTA-FR torch adhered to base or ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -60 psf. (See General Limitation #7) Pressure: NOA No.: 18-1127.18 MIAMIUU COUNTY • • • , , Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 31 of 49 Membrane Type: SBS Modified Deck Type 1: Wood, Non -Insulated Deck Description: 19/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 4" o.c. at wood joists spaced maximum 24" o.c. System Type E(8): Base sheet mechanically fastened. All General and System Limitations apply. Base Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet or Flintglas Premiam Ply 6 mechanically attached as detailed below. Fastening #1: Base sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c. Ply Sheet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase (Optional) Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or one or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to the base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or Flintlastic Ultra Poly SMS Base Sheet torch adhered. Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR- P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base or ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR Cap 30 T torch adhered to base or ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -60 psf. (See General Limitation #7) Pressure: Mu1MMALDE COUNTY NOA No.: 18-1127.18 •, , Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 32 of 49 Membrane Type: SBS Modified Deck Type 1: Wood, Non -Insulated Deck Description: "/32" or greater plywood or wood plank attached with #8 wood screws spaced 6" o.c. at wood joists spaced at maximum 24" o.c. System Type E(9): Base sheet mechanically fastened All General and System Limitations apply. Separation Sheet: One or more plies of Glasbase Base Sheet, loose laid. (Optional) Base Sheet: One or more plies of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexibase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet, mechanically attached as described below. Fastening #1: Anchor sheet shall be fastened with FBC HVHZ nails and tin caps spaced 6" o.c. at the 3" lap and 6" o.c. in four, equally spaced staggered center rows. Ply Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA, self -adhered to the base sheet. Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR- P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR Cap 30 T torch adhered to ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -60 psf (See General Limitation #7) Pressure: MIAM4DADE COUNTY NOA No.: 18-1127.18 . • • •, � Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 33 of 49 Membrane Type: APP Modified Deck Type 1: Wood, Non -Insulated Deck Description: 19/32" or greater plywood or wood plank attached with #8 wood screws spaced 6" o.c, at wood joists spaced maximum 24" o.c. System Type E(10): Base sheet mechanically fastened All General and System Limitations apply. Separation Sheet: One or more plies of Glasbase Base Sheet, loose laid. (Optional) Base Sheet: One or more plies of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexibase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet, mechanically attached as described below. Fastening #1: Anchor sheet shall be fastened with FBC HVHZ nails and tin caps spaced 6" o.c. at the 3" lap and 6" o.c. in four, equally spaced staggered center rows. Ply Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA, self -adhered to the base sheet. Membrane: One ply of Flintlastic GTA or Flintlastic GTA-FR torch adhered to ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -60 psf (See General Limitation #7) Pressure: NOA No.: 18-1127.18 nu+nEonoe courm Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 34 of 49 Membrane Type: SBS Modified Deck Type 1: Wood, Non -Insulated Deck Description: 19/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 6"o.c. at wood joists spaced maximum 24" o.c. System Type E(11): Base sheet mechanically fastened All General and System Limitations apply. Separation Sheet: One or more plies of Glasbase Base Sheet, loose laid. (Optional) Base Sheet: One or more plies of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet, mechanically attached as described below. Fastening #1: OMG #12 Standard Roofgrip fasteners with OMG 3" Galvanized Steel Plates or AccuTrac Plates or Trufast #12 DP fasteners with Trufast 3" Metal Insulation Plates or Flintfast 912 fasteners with Flintfast 3" Insulation Plates spaced 7" o.c. at the 4" wide laps and 7" o.c. in two, equally spaced staggered center rows. Ply Sheet: One ply of Flintlastic Ultra Glass SA, self -adhered to the base sheet. Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR- P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR Cap 30 T torch adhered to ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -67.5 psf. (See General Limitation 47) Pressure: ML4MIAADE COUNTY NOA No.: 18-1127.18 • • • � � Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 35 of 49 Membrane Type: SBS Modified Deck Type 1: Wood, Non -Insulated Deck Description: - 15/32" or greater APA rated plywood or wood plank attached with #8 screws spaced 6" o.c. at wood joists spaced maximum 24" o.c. System Type E(12): Base sheet mechanically fastened All General and System Limitations apply. Base Sheet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet, mechanically attached as described below. Fastening #1: Cap nails: 1" diameter, 0.032" thick metal cap with 0.120" shank diameter, annular ring shank nails spaced 6" o.c. at the 4" wide laps and 6" o.c. in five, equally spaced staggered center rows. Ply Sheet One ply of Glasbase Base Sheet, All Weather/Empire Base Sheet, Flexiglas Base Sheet, (Optional): Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet adhered to base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one ply of Glasbase Base Sheet, All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Base 20 T or Flintlastic Ultra Poly SMS Base torch applied to base sheet. Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR- P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base or ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or one ply of Flintlastic FR Cap 30 T torch adhered to base or ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -67.5 psf. (See General Limitation #7) Pressure: NOA No.: 18-1127.18 Expiration Date: 06/1923 Approval Date: 01/17/19 Page 36 of 49 Membrane Type: SBS Modified Deck Type 1: Wood, Non -Insulated Deck Description: 19/32" or greater plywood or wood plank attached with #8 wood screws spaced 6" o.c. at wood joists spaced maximum 24" o.c. System Type E(13): Base sheet mechanically fastened All General and System Limitations apply. Base Sheet: One or more layers of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or All Weather/Empire Base Sheet, mechanically attached as described below. Fastening #1: Anchor sheet shall be fastened with HVHZ nails and tin caps spaced 6" o.c. at the 3" lap and 6 o.c. in four, equally spaced staggered center rows. Ply Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered to the base sheet. Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR- P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR Cap 30 T torch adhered to ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -82.5 psf (See General Limitation #7) Pressure: NOA No.: 18-1127.18 Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 37 of 49 Membrane Type: APP Modified Deck Type 1: Wood, Non -Insulated Deck Description: 19/32" or greater plywood or wood plank attached with #8 wood screws spaced 6" o.c. at wood joists spaced maximum 24" o.c. System Type E(14): Base sheet mechanically fastened All General and System Limitations apply. Base Sheet: One or more layers of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or All Weather/Empire Base Sheet, mechanically attached as described below. Fastening #1: Anchor sheet shall be fastened with HVHZ nails and tin caps spaced 6" o.c. at the 3" lap and 3 o.c. in four, equally spaced staggered center rows. Ply Sheet: One ply of Black Diamond Base Sheet, self -adhered to the base sheet. Membrane: One ply of Flintlastic GTA or Flintlastic GTA-FR torch adhered to ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -82.5 psf (See General Limitation #7) Pressure: MAMMADE COUNTY NOA No.: 18-1127.18 FR , Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 38 of 49 Membrane Type: SBS Modified Deck Type 1: Wood, Non -Insulated Deck Description: 15/32" or greater CDX plywood or wood plank attached with #10 wood screws spaced 6" o.c. at wood joists spaced maximum 24" o.c. System Type E(15): Base sheet mechanically fastened. All General and -System Limitations apply.. Base Sheet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, All Weather / Empire Base Sheet, Flintlastic Base 20 or Flintlastic Poly SMS Base Sheet mechanically fastened with Simplex MAXX Cap fasteners spaced 6" o.c. in the 2" side lap and 6" o.c. in two evenly divided, staggered rows in the center of the sheet. Membrane: One ply of Flintlastic FR Cap 30, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-P, Flintlastic Cap 30 or Flintlastic GMS adhered to the base sheet with approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs/sq. or one ply of Flintlastic FR Cap 30 T, torch -applied to base sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -90 psf. (See General Limitation #9) Pressure: NOA No.: 18-1127.18 Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 39 of 49 Membrane Type: APP Modified Deck Type 1: Wood, Non -Insulated Deck Description: 15/32" or greater CDX plywood or wood plank attached with # 10 wood screws spaced 6" o.c. at wood joists spaced maximum 24" o.c. System Type E(16): Base sheet mechanically fastened. All -General and System Limitations apply. Base Sheet: One ply of Flintlastic APP Base T mechanically fastened with Simplex MAXX Cap fasteners spaced 6" o.c. in the 2" side lap and 6" o.c. in two evenly divided, staggered rows in the center of the sheet. Membrane: One ply of Flintlastic GTA or Flintlastic GTA-Flt, torch -applied to the base sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -90 psf. (See General Limitation #9) Pressure: NOA No.: 18-1127.18 MIAMI-DADECOUNW Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 40 of 49 Membrane Type: SBS Modified Deck Type 1: Wood, Non -Insulated Deck Description: 15/32" or greater CDX plywood or wood plank attached with #10 wood screws spaced 6" o.c. at wood joists spaced maximum 24" o.c. System Type E(17): Base sheet mechanically fastened. All General and -System Limitations apply Base Sheet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet mechanically attached as described below. Fastening #1: Fastened with Trufast #12 DP Fastener or Trufast #14 HD Fastener with Trufast 3" Metal Insulation Plate, OMG Heavy Duty fasteners with 3 in. Round Metal Plates, OMG AccutTrac Hextra with AccuTrac Flat Bottom plates, FlintFast #12 fasteners or FlintFast #14 fasteners with FlintFast 3" Insulation Plates spaced 6" o.c. at the 4" lap and 6" o.c, in three, equally spaced staggered center rows. Ply Sheet: One or more plies of Glasbase Base Sheet, All Weather/Empire Base Sheet, Flexiglas Base (Optional) Sheet, Flintlastic Base 20, Flintlastic Ultra Poly SMS Base Sheet adhered to the base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq. or one or more plies of Flintlastic Base 20 T or Flintlastic Ultra Poly SMS Base Sheet, torch applied. Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR- P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base or ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 401bs./sq. or one ply of Flintlastic FR Cap 30 T torch adhered to base or ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -97.5 psf. (See General Limitation #7) Pressure: NOA No.: 18-1127.18 Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 41 of 49 Membrane Type: SBS Modified Deck Type 1: Wood, Non -Insulated Deck Description: 15/32" or greater APA rated plywood or wood plank attached with # 10 wood screws spaced 6"o.c. at wood joists spaced maximum 24" o.c. System Type E(18): Base sheet mechanically fastened All General and System Limitations apply Base Sheet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet, mechanically attached as described below. Fastening #1: Fastened with Tmfast # 14 HD Fasteners with Trufast 3" Metal Insulation Plates or FlintFast #14 Fasteners with FlintFast 3" Insulation Plates spaced 8" o.c. at the 4" wide laps and 8" o.c. in three, equally spaced staggered center rows. Ply Sheet One ply of Glasbase Base Sheet, All Weather/Empire Base Sheet, Flexiglas Base Sheet, (Optional): Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet adhered to base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one ply of Glasbase Base Sheet, All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Base 20 T or Flintlastic Ultra Poly SMS Base torch applied to base sheet or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered to base sheet. Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR- P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base or ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or one ply of Flintlastic FR Cap 30 T torch adhered to base or ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -97.5 psf. (See General Limitation #7) Pressure: NOA No.: 18-1127.18 Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 42 of 49 Membrane Type: SBS Modified Deck Type 1: Wood, Non -Insulated Deck Description: 15/32" or greater CDX plywood or wood plank attached with # 10 wood screws spaced 4" o.c. at wood joists spaced maximum 24" o.c. System Type E(19): Base sheet mechanically fastened. All General and System Limitations apply Base Sheet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, All Weather / Empire Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet mechanically fastened with Simplex MAXX Cap fasteners spaced 6" o.c. in the 2" side lap and 6" o.c. in three evenly divided, staggered rows in the center of the sheet. Membrane: One ply of Flintlastic FR Cap 30, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-P, Flintlastic Cap 30 or Flintlastic GMS adhered to the base sheet with approved mopping asphalt applied within the EVT range and at a rate of 2040 lbs/sq. or one ply of Flintlastic FR Cap 30 T, torch -applied. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -105 psi (See General Limitation #9) Pressure: MIAMI•DADE COUNTY NOA No.: 18-1127.18 . • • • . , Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 43 of 49 Membrane Type: APP Modified Deck Type 1: Wood, Non -Insulated Deck Description: 15/32" or greater CDX plywood or wood plank attached with # 10 wood screws spaced 4"o.c. at wood joists spaced maximum 24" o.c. System Type E(20): Base sheet mechanically fastened. All -General and -System Limitations apply. Base Sheet: One ply of Flintlastic APP Base T mechanically fastened with Simplex MAXX Cap fasteners spaced 6" o.c. in the 2" side lap and 6" o.c. in three evenly divided, staggered rows in the center of the sheet. Membrane: One ply of Flintlastic GTA or Flintlastic GTA-FF, torch -applied to the base sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -105 psf. (See General Limitation #9) Pressure: NOA No.: 18-1127.18 Expiration Date: 06/1923 Approval Date: O1/17/19 Page 44 of 49 Membrane Type: SBS Modified Deck Type 1: Wood, Non -Insulated Deck Description: 19/32" or greater plywood or wood plank attached with #8 wood screws spaced 6" o.c. at wood joists spaced maximum 24" o.c. System Type E(21): Base sheet mechanically fastened All General and System Limitations apply. Base Sheet: One or more plies of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet, mechanically attached as described below. Fastening #1: Base sheet shall be fastened with OMG 12 Standard Roofgrip fasteners with OMG 3 in. Round Metal Plates or AccuTrac Plates or Trufast #12 DP fasteners with Trufast 3" Metal Insulation Plates or F1intFast #12 Fasteners with F1intFast 3" Insulation Plates spaced 7" o.c, at the 4" lap and 7 o.c. in three, equally spaced center rows. Ply Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered to the base sheet. Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR- P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR Cap 30 T torch adhered to ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -105.0 psf (See General Limitation 47) Pressure: MIAMFDADE COUNTY NOA No.: 18-1127.18 . • • • . � Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 45 of 49 Membrane Type: SBS Modified Deck Type 1: Wood, Non -Insulated Deck Description: 19/32" or greater plywood or wood plank attached with 48 wood screws spaced 6" o.c. at wood joists spaced maximum 24" o.c. System Type E(22): Base sheet mechanically fastened All General and System Limitations apply. Separation Sheet: One ply of Glasbase Base Sheet, loose laid. (Optional) Base Sheet: One or more plies of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexibase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet, mechanically attached as described below. Fastening #1: Base sheet shall be fastened with FBC HVHZ nails and tin caps spaced 4" o.c. at the 3" lap and 4" o.c. in four, equally spaced center rows. Ply Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA, self -adhered to the base sheet. Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR- P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 401bs./sq. or Flintlastic FR Cap 30 T torch adhered to ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -105 psf (See General Limitation 47) Pressure: NOA No.: 18-1127.18 MIAMI-DADE COUNTY ,.... � Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 46 of 49 Membrane Type: APP Modified Deck Type 1: Wood, Non -Insulated Deck Description: 19/32" or greater plywood or wood plank attached with #8 wood screws spaced 6" o.c. at wood joists spaced maximum 24" o.c. System Type E(23): Base sheet mechanically fastened -All General -and -System Limitations apply. - Separation Sheet: One ply of Glasbase Base Sheet, loose laid. (Optional) Base Sheet: One or more plies of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexibase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet, mechanically attached as described below. Fastening #1: Base sheet shall be fastened with FBC HVHZ nails and tin caps spaced 4" o.c. at the 3" lap and 4" o.c. in four, equally spaced center rows. Ply Sheet: One ply of Black Diamond Base Sheet, self -adhered to the base sheet. Membrane: One ply of Flintlastic GTA or Flintlastic GTA-FR torch adhered to ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -105 psf (See General Limitation #7) Pressure: NOA No.: 18-1127.18 Expiration Date: 06/19/23 Approval Date: O1/17/19 Page 47 of 49 Membrane Type: SBS Modified Deck Type 1: Wood, Non -Insulated Deck Description: "/32" or greater CDX plywood or wood plank attached with #10 wood screws spaced 4" o.c. at wood joists spaced maximum 24" o.c. System Type E(24): Base sheet mechanically fastened. All General and -System Limitation as pp y— Base Sheet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet mechanically attached as described below. Fastening #1: Fastened with Trufast #12 DP Fastener or Trufast 414 HD Fastener with Trufast 3" Metal Insulation Plate, OMG Heavy Duty fasteners with 3 in. Round Metal Plates, OMG AccutTrac Hextra with AccuTrac Flat Bottom plates, FlintFast #12 fasteners or FlintFast #14 fasteners with FlintFast 3" Insulation Plates spaced 6" o.c. at the 4" lap and 6" o.c. in four, equally spaced staggered center rows. Ply Sheet: One or more plies of Glasbase Base Sheet, All Weather/Empire Base Sheet, Flexiglas Base (Optional) Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet adhered to the base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one or more plies of Flintlastic Base 20 T or Flintlastic Ultra Poly SMS Base Sheet, torch applied. Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR- P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base or ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or one ply of Flintlastic FR Cap 30 T torch adhered to base or ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -127.5 psf. (See General Limitation #7) Pressure: MIAMI-DADE COUNTY �Fj.... NOA No.: 18-1127.18 Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 48 of 49 VJ WOOD DECK SYSTEM LIMITATIONS: A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LIMITATIONS: 2.- 3. to 5. 22 91 .0 10. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. Insulation may be installed -in multiple Iayers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psE Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 Ibf insulation attachment shall not be acceptable. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS It 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended comers and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. MIAMI.�FjDADE COUNTY .... l END OF THIS ACCEPTANCE NOA No.: 18-1127.18 Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 49 of 49