Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNI�T_HE GRAND CARLTON Builder Name: WYNNE BUILDING COPR. Street: \%­k \ kz) Permit Office: ST. LUCIE COUNTY 4GC/ e.v�Q City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: WYNNE BUILDING CROP Design Location_ Jurisdiction: ST. LUCIE COUNTY COI. FL, Fort Pierce _ County:: St. Lucie (Florida Climate Zone 2) 1. New construction or existing New (From Plans) 9. Wall Types (1442.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R=11.0 192.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling Types (1446.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1446.00 ft= 6. Conditioned floor area above grade (ft2) 1446 b. N/A R= ft2 Conditioned floor area below grade (W) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(141.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 250 a. U-Factor: Sgl, U=0.36 101.25 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 34.8 SEER:15.00 c. U-Factor. N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.239 14. Hot water systems 8. Floor Types (1445.5 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft2 b. Conservation features EF: 0.970 b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.098 Total Proposed Modified Loads: 47.17 PASS Total Baseline Loads: 48.08 1 hereby certify that the plans and specifications covered by Review of the plans and HE Srgls this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance q ii„''' ;f;� .n with the Florida Energy Code. � nm.. ••••. •^;:; ; ;,,:• „ O PREPAR D Y' Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 2 O y ° I hereby certify that this building, as designed, is in compliance Florida Statutes. l,1, with the Florida Energy Code. t''0 WE OWNER BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FILE r% t'ooply 4/17/2018 4:06 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 PROJECT Title; WYNNE THE GRAND CARL Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1446 Lot # Owner Name: WYNNE BUILDING CROP Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180 Street: Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, - .New/Existing: -New-(From Plans) - — -- - - - - - -- Comment: CLIMATE _ / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1446 11568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 301 2408 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS S moor I ype Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 301 ft' 0 1 0 2Slab-On-Grade Edge Insulatio WIC 1 ft 0 63 ft' ___ 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft' 0 1 0 4Slab-On-Grade Edge Insulatio KITCHEN 1 ft 0 192 ft' _-_ 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft' 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 It 0 203.6 ft' -_ 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft' ____ 0 1 0 4/17/2018 4:06 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 FLOORS # - Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 ____ 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft2 ___ 0 1 0 ROOF / Roof Gable Roof Solar SA Emilt Emitt Deck Pitch V # Type. - - Materials - Area Area Color Absor. Tested- Tested Insul. (deg) 1 Gable or Shed Metal 1524 ft2 240 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1446 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Free Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 301 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NE=>SW Exterior Concrete Block - Ext Ins®EDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 2 SW=>NE Exterior Concrete Block - Ext Ins®EDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.6 0 3 NW=>SE Exterior Concrete Block - Ext Ins®EDRGOM 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0 4 SW=>NE Exterior Concrete Block- Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 5 NE=>SW Exterior Concrete Block- Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.6 0 6 NE=>SW Exterior Concrete Block - Ext InfiffDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.6 0 7 SE=>NW Exterior Concrete Block - Ext InfiffDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 _ 8 S=>N Exterior Concrete Block - Ext InEEDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.6 0 9 SW=>NE Exterior Concrete Block - Ext InMEDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 10 SE=>NW Exterior Concrete Block -Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.6 0 12 SW=>NE Exterior Concrete Block - Ext Insd1AUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 13 NE=>SW Exterior Concrete Block- Ext InsGREAT/DINT 4.1 26 0 8 0 208.0 ft2 0 0 0.6 0 14 NW=>SE Exterior Concrete Block- Ext InsOREAT/DINI 4.1 20 0 8 0 160.0 ft2 0 0 0.6 0 15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft2 0.23 0.6 0 4/17/2018 4:06 PM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 DOORS # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft' WINDOWS Orientation shown is the entered orientation => chanced to Worst Case. / Wall V # Omt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE-3- —Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW13 Metal 5 NW=>SE14 Metal tow-E-Single --Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes 0.36 0.25 -N 32.9 ft' 1 ft-0 in 1 ft 4 in 0.36 0.25 N 6.9 ft' 1 It 0 in 1 ft 4 in 0.36 0.25 N 24.0 ft' 6 ft 0 in 1 ft 4 in 0.36 0.25 N 37.5 ft' 1 ft 0 in 1 It 4 in 0.65 0.21 N 40.0 ft' 8 ft 0 in 1 ft 4 in Drapes/blinds None None None Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft' 315 ft' 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1349.6 74.09 139.34 .2598 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF CapUse SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft' 4/17/2018 4:06 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 DUCTS J. — Supply — -- Return — Air CFM 25 CFM25 HVAC # it Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 250 ft' Attic 65 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programablre'Thermostat: Ceiling Fans: - Heat ng - -[X] Jan ']Y - -1 Feb [[ � [X] Mar [ ] -[ ]-AAp� -j May r[[ ]J] rl Jun- r ]] Jul-- [[ ]] [x] Aug [[ ]] !XJ Sep OOctt Oct Nov H Dec Vents [[ ]1 Jan [ 1 Feb l IIX1l Mar [X] [ L [ 1 Jun [ Jul lXJ II 11 Aug I[ 11 Sep X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 8o 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4/17/2018 4:06 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR. Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind ninino and wirmno Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire. Rnrinkler cover plates and walls or ceilinas a. In addition, inspection of log walls shall be in accordance with the provisions of IGG-400. 4/17/2018 4:06 PM EnergyGaugeO USA- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. - -- FT. PIERCE, FL, - 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft' b. Frame -Wood, Adjacent R=11.0 192.00It' 3. Number of units, if multiple family 1 c. N/A R= fP 4. Number of Bedrooms 2 d. N/A R= fP 5. Is this a worst case? Yes 10. Ceiling Types Insulation Area a. Under Attic (Vented) R=30.0 1446.00 ft' 6. Conditioned Floor area (ft') 1446 b. N/A R= ft' 7. Windows" Description Area c. N/A R= ft' a. U-Factor: Sgl, U=0.36 101.25 ft' 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic R ft' 6 250 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 40.00 ft' SHGC: SHGC=0.21 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft' a. Central Unit 34.8 SEER:15.00 SHGC: d. r: N/A ft' SHGC: SHGC: 13. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 3.832 ft. a. Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average SHGC: 0.239 8. Floor Types Insulation Area 14. Hot water systems a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft' a. Electric Cap: 40 gallons b. N/A R= ft' EF: 0.97 c. N/A R= ft' b. Conservation features None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant feat w_s Builder Signature: Date: \ Address of New Homer=k �� �,¢� City/FL Zip: \ • ��C2 ­4�t4 S 'Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. "Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/17/2018 4:06 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 + wrightsoft° ' Project Summary Entire House QUICK CALCS, INC. Job: Date: By: For. THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL a0Ae Notes: Weather. Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Fort Pierce, FI US Heating Summary Structure 17848 Btuh Ducts 5654 Btuh Central vent (0 cfm) 0 Btuh (nave) Humidification 0 .Btuh Pi in Equipment load 23503 Btuh ` Infiltration Method Construction quality Fireplaces Simplified Average 0 Area ftz Hea144g CoaMt Volume (ftj 12511 12511 Air changesthour 0.45 0.23 Equiv. AVF (cfm) 94 48 Heating Equipment Summary Make Cartier Trade CARRIER AIR CONDITIONING Model 25HBC536MO30 AHRI ref 7914585 8.5 HSPF 34600 Btuh @ 47°F 27 OF 1160 cfm 0.049 cfm/Btuh 0.60 in H2O point = 32 OF Backup: Input = 7 kW, Output = 23009 Btuh, 100 AFUE 'St LUCie cou ty .Summer Design Conditions Outside db 90 OF Inside db 75 OF. Design TD 15 OF Daily range L Relative humidity 50 %. Moisture difference 61 gr/lb Sensible Cooling EquipmentLoad Sizing Structure 17520 BtuhDuct 8530 _ Central vent (0 cfm) Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swirigg multipplier Equipmertf sensible toad 0.95 24753 Btuh Latent Cooling Equipment Load Sizing Structure 3203 Btuh Ducts 2318. Btuh Central vent (0 cfm) 0 Btuh (none)' Equipment latent load 5521 Btuh Equipment total load 30274 Btuh Req. total capacity at 0.70 SHR 2.9 ton Cooling Equipment Summary Make Cancer Trade CARRIER AIR CONDITIONING Cond 25HBC536A*030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800. Btuh Actual airflow 1160. cfm Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.83 meet all requirements of * wrightsoft RightSuiteO Universe 1201717.0.14 RSU08101 ...uick CaleslDoouments\THE GRAND CARLTON.1446.rup Calo = MJ8 Front Door faces: N J 8th Ed. 2017-Apr-11 09:29:38 Page 1 + wrightsoft' RighWO Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LLICIE I.N., FT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Emil: OUCKCALCSC&AOL.COM I Room new, Entire House BEDROOM 2 Spmed wall 156.2 It 49.0 It 3 Room height 8.7 It d 8.0 ft heal/Cool 4 Room dimensions 1.0 x 297.0 ft 6 Room area 1445.5 ft2 297.0 ft2 Ty Construction U-Value Or HTM Area (ft5 Load Am (ft2) Load _I number atuhi`I`V�F) w (Btu" or perimeter (ft) (Btuh) or perimeter _ (ft)_ (Btuh) Heat FC-T Gross NIPIS Heat cool Gross N/PIS Heat cool 6 13A4ocs4 0 - 143 n 4.00 255 503 465 1862 1184 72 %'72 2BB -183 4A6-2omr,. :O.iib —n 21.56 19.31 38 T815 .730 �0 0 �O 0 V�j 13A4ocs 0.143 e 4.00 255 128 83 333 212 0 0 0 0 1A-cIcm 1270 e 35.56 87.29 24 2 848 2082 0 0 0 0 11 11DO 0.390 e 10.92 11.31 21 21 229 238 0 0 0 0 ,W.�Jz '1144=: �:0.143 use-. 4.00 ZS -34 136 ....... 86 .0 ,o 0 Y—a 13A-4ocs 0.143 s 4.00 255 300 353 1414 899 216 - - 216 865 '��o 550 1A-clam 1270 s 35.56 34.77 7 7 247 241 0 0 0 0 6.143 -'v 4:00 �255 310 603 104 72 288 183 -1.270 35.56 ��5521 32 2 T -Aw �1 7�70 32 2 1140 �—,",1770 .7m w -2156 19 31 -'41 41 - "" I'0 -;,o 5�'� _ P 12C-Gsw -,j6X3ftd, 6.091 2.55 1.28 192 192 489 246 0 0 0 C O.W 0.g0 232 1446 1446 1295 3354 297 297 266 669 F 22A-tpl 0.989 27.69 0.00 1446 156 4325 0 297 49 1357 0 z 6 c)AED ooLvelm 918 627 Ermlope loss/gain 14961 13349 4204 4003 12 a) infiltration 2987 791 848 232 b) Roonnvardilation 0 0 0 0 13 Interrkl gains: Occupants @ 230 6 1380 3 690 Appliances/other 2000 0 Subtotal pines 6 to 13) 17848 175M Sm 492 . 5 Less wdemal load 0 01 0 0 0 Less bander 0 0 0 0 Redistribution 0 0 0 0 0 0 14 Stbotal 17M8 17520 5MF 4926 1151 Duct loads 320% 49% 5654 8536 32-1.1 490% 160, 00 2400 Total room load 235M 26056 6653 7325 Air required (cfm) 116D 1160 328 326 Calculations approved by ACCAItoaieet all requirements of Manual J 8th Ed. Right-SufteO Universal 2017 17.0. 14 RSU08101 2017-Apr-11 09:29:38 ...nick CalcS\D0cUmntS\THE GRAND CARLTON-1446.mp Calc=MJ8 FrontDoorfaces: N Pagel wrightsoft Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT, PIERCE, FL 34946 Phone: 772-466E799 Fax 772466-6796 Email: OUICKCALCS@gOL.COM 1 Room name WIC IQTCHEN 2 EVMedwall Oft . Oft 3 Room height 8.0 If heat/cool 8.0 ft heal/cool 4 . Room dimensions 6.0 x 9.0 It 1.0 x 172.0 R 5 Room area 54.0 ft2 172.0 ft' Ty Construction U-%,Aue Or HTM Area (ft0 Load Area Load number I (Btuh/ft-F) (BtuMft2) or perimeter (ft) (Btuh) or perimeter - (ft). _ , (Bluh) Heat Cod Gross NIPIS Heat Cool Gross WPIS Heat Cod 6 ! 13A-0acs - `•0143 n - 400 - .,255 .0 0 - 0,, :.0. a .... 0 "p0 4 2am ". + :'. -.D.770 ;. n: - 21.56 " , 19.31 :.::0 . .0 _ ._, 0" 0' . , 0 ,0 4'0.' " 0 , •,'-0 III--G im4ccs 0.143 a- 4.00 2.55 0 0 0 0 0 0 0 0 1Actom 1270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 I--D 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W'^. 13Aocs'::' -- '- - ' 0143 se`.- 4.00 :: r255 :. 0. '0 .-0.-..:: 0. 0 0 '-:0 �` 0 ,•',;1 i^:;0 Vy 13AAocs 0143 s 4.00 255 0 0 0' 0 0- 0 0 I- .G 1A-cl m 1270 s 3556 34.77 0 0 0 0 0 0 0 0 -- 13A46cs L.'.J0143 w, - 400 ;255 0; D 0 - 0 '0- `0 -- 0 0 10.c1om 1270 w -: 3566 .:65.21 0 <: 0 :- ': 0 _; p 0 0 ;. O r 10 4AS2om - •.0.770 w "21.56 - .99:310 0:;- .'0 °. -".0 0- .0. 0 P 12C-0sw 0.091 - 255 1.28 0 0 0 0 64 64 163 82 C ..16A30md 0.032 - -0.90 232 54 64 -._ 48 125 172 172 154 F 22AADI 0.989 27.69 0.00 54 0 0 0 172 0 0 . ,399 0 6 c)AED mumim -g -170 Emelope lmstgain 48 117 317 311 12 a) IMiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 internal gains: Occupants @ 230 0 p p 0 Applianceslother p 2000 Subtotal (lines 6 to 13) 48 117 317 2311 Less mdemal load 0 0 D 0 Less transfer 0 0 0 0 Redistribution 0 0 14 Subtotal 48 117 317 23'I� 15 Duct loads 32% 49% 15 57 32% 49% 100 1126 Total mom load 64 174 418 3437 Air required (cfm) 3 8 21 163 Calculations approved byACCA to meet all requirements of Manual J 8th Ed A wri htsof-v Right -Suite® Universal 2017 17.0.14 RSU08101 B 2017-Apr-11 09:29;38 ...ulcK CalcslDocumentslTHE GRAND CARLTON4446.mp Calc=MJB Front Door faces: N Page 2 4 wrightsoft Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 1 Room name WH BEDROOM 2 F�plosed wall 5.0 ft 34.2 ft 3 Rcom height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 9.0 x 5.0 ft 1.0 x 203.5 R 5 Room. area 45.0 ft2 203.5 ft- Ty Construction U-wlue Or HTM Area (W) Load Area (fl2) - Lnad - - number. — - - - - (BtuNftk'F) - - (Btuh/ft2) a_perime_ter (ft) _ Btuh)_ -(_ or _ Perimeter (ft). - - - _ (Btuh) - - - Heat Cod Gnus WP/S Heat Cool Gross WP/S Heat Cool 6 13Aaocs .: �. ;0143 ,n .4.00 `-- -Z55 40 P: 40 160 • s102 128 ' 128' S13 =. 326 ;0.770 n .^':. 2156 �, _ 19.31 ,." : 01. . .:0... ; 0' ,. • ; ` "0 0 ... p ._•;. p ;0 V 13A-4ocs 0.143 a 400 255 0 0 0 0 80 58 225 - 143 �LCD 1Aclom 1.270 a 3556 87.29 0 0 0 0 24 2 848 2082 11 11DO 0.390 a 10.92 11:31 0 0 0 0 0 0 0 0 ;13A40CA-- -. . - :... 0.143 ''se - , ` 4.00 ' 2.55 . .' `,.0 - . 0 <.._ '0 =- ,. - 0 <: 34 34 --.. 136 .....z '88 V!/ 13A-0ocs 0.143 s a00 2.55 0 0 . 0. 0 32 .32 `- 128 -,. 81 l—G 1Actorn 1270 s 3556 34.77 0 0 0 0 0 0 0 0 13A-0acs .. -:0143 w - 400 2.55 0'- 0 0 0 -' 0 0 0 - ;0 1"lcfn - 1270 w :' 3556 55i21 0 0 0 _0 0 0 -" 0 :0 >2156 ..19.31 0 : ._ W .: 0 , 0 rla:0 P 12C-0sw 0.091 - - 2.55 1.28 0 0 0 0 0 0 0 -- 0 C - 16430ind .. 0.032 - 0.90 232 - 45 45 40 104 204 204 182 ', 472 F 2244ol _ . 0.989 V.69 0.00 45 5 138 0 204 34 946 0 Envelope loss/gain 1- 3391 190 2978 3106 12 a) Mitration - 87 24 593 162 b) Room ventilation 0 0 0 0 13 Internal gams: Occupants @ 230 0 0 1 230 Appliances/other p 0 Subtotal Oines Etc 13) 425 214 3571 3498 Less odemal load 0 0 - 0 0 Less transfer 0 0 0 0 Redistribution 14 Subtotal 425 214 3571 3498 15 Duct loads 32% 49% 135 104 32% 49% 1131 1704 2 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed ,&A 4t- wrightts ft- RlghtSufteO Universal 2017 17.0.14 RSU08101 2017-Apr-11 09:29:38 ...ulck CalcstDocwments%THE GRAND CARLTON-1446.mp Colc = MJ8 Front Door faces: N Page 3 m O x �nv nOo ooOoo�opo �m a.. .. ",FN OJ O d N aSf 1t�0000000�OpO�N. -' - - Ht4�7 N e y O OO OO OO OO.O- � lV N V T b �d 000 oOO!N000- OES�m o N d e aori N c 000 ooA�oaO;4 `�ivv o e �t7N NM N�mn NlCl f7NM0 '$ NmNm�ciN�Nu���No , U 1pp�� �O (m�Gp {{yy nOn Oppp� �� 000 000 o dddo � 65 o o MShi �°m� �^��'3��a Nis p ra _ •:.. �NMON N N N N �P I + wrightsoftRight-M Worksheet Job: Entire House Date: • QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone; 772-4686799 Fas 772-4666796 Email' OUICKCALCS@AOL.COM 1 Room name FOYER M. BATH 2 EVosed wall 7.0 ft 8.0 ft 3 4 Room height Room dimensions 8.0 ft heat/cool 8.0 ft heat/cocl 5 Room area 1.0 x 50.0 ft 50.0 ft- 7.0 x 8.0 ft 56.0 ft- Ty Construction U-value Or HTM Area (ft' Load Area (ft.) Load number (Btulyftk*F) (BtulVft2) or perimeter (ft)_ Mtuh) a perimeter- (ft)- _(Btuh) -_ Heat Cool Gnus WP/S Heat Cool Gross WP/S Heat Cool 6 . - 13A-0ocs 0143 t, n 400 2.65 ' 8 .8 32 -. 20 `..... .-. 0 0':` .. 0 -- pAS2am.....i` ;0770 _ n.; ; 2156 :� .49.31 0-. 0 : .0 0 `. ,- 00 V 13A 40CS 0.143 a 4.00 Z55 48 27 108 69 0 0 0 0 1Aclom 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 11D0 '.13A-0acs. ..� 0.390 "'_0.143 a 10.92 11.31 ' 21 21 229 238 0 0 0 0 se .4.0D 'Z55, �0: �0 .:, ., O C '..'0.. 0 .0' p r. -:;sp Y}/ 13AAccs 0.143 s 4.00 2.55 0 0 0 0 64 87 228 145 1Ac1om 1270 s 3556 34.77 0 0 0 0 7 7 247 241 If- 13A-0ces ;0143 w, ,. " 400 ' 2.55 0 0 .. 0 0 0 . 0 0 :0 1Actom '`., 1270 w 3556 .. 55:21 i 0-:. 0 0 . -0 ...o' 0', 0 ,, +�:0 P ;4A-20m 12C-0sw .;0770 0.091 w ;-�2156' 19:31 0: 0 0^-. 0 ,. o. '0 0. Sr'0. ". - Z55 1.28 72 72 183 92 0 0 0 0 C 16A-30md 0.032 - 0.90 2.32 50 5o 45 116 56 56 50 F 27A•tpl 0.989 - 27.69 0.00 50 7 194 0 56 8 222 _.13p 0 6 c)AED excursion -39 46 Envelope loss/gain 792 496 747 478 12 a) Infiltration 12 33 13 38 b) Room ventilation 0 0 0 0 0 13 hernial gains: Occupants @ 23D 0 p 0 Apprianceslother 0 p 0 Subtotal pines 6 to.13) 913 529 8&5 516 Less edamal load 0 0 0 Less transfer . 0 0 0 Redistribution 0 0 0 0 14 15 Sutotal Duct loads 913 529 0 885 0 516 32% 49% 289 258 32% 49% 280 251 Total room load Air required(cfm) 1259 787 1158 768 59 35 58 34 Calculations approved byACCA to meet all requirements of Manual J 8th R. ' wrightsoft• 2017• r-11 09:29:38 RlghtSulteO Universal 2017 17.0.14 RSU08101 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Cale = MJB Front Door faces: N page 5 -- wrightsoft° Duct System Summary EntireDate: House Dat QUICK CALCS, INC. 317 ST. LUCIE LN.. FT. PIERCE, FL 34946 Phone: 772466-6799. Fax 77246"796 Email OUICKCALCS AOLCOM For. THE GRAND CARLTON WYNNE DEVELOPMENT,. FT. PIERCE, FL - - Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply / return available pressure 0.250 / 0.250 in H2O 0.250 / 0.250 in H2O Lowest friction rate 0.285 in/100ft 0.285 in/100ft Actual airflow 1160 cfm 1160 cfm Total effective length (TEL) 176 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (In) H x W (in) Duct Mat] Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 560 28 14 0.364 4.0 Ox0 VIFx 22.4 115.0 SO BEDROOM 2 h 4702 232 232 0.360 7.0 Ox0 VIFx 23.9 115.0 st1 BEDROOM -A h 3327 164 163 0.300 6.0 Ox0 VIFx 31.8 135.0 St2 REDROOM43 h 3327 164 163 0.285 6.0 Ox0 VIFx 40.6 135.0 st2 FOYER h 1202 59 35 0.505 4.0 0x0 VIFx 4.0 95.0 GREAWDINING h 3946 195 169 0.300 7.0 Ox0 VIFx 31.8 135.0 st2 GREATIDINING-A h 3946 195 169 0.300 7.0 OxO VIFx 31.8 135.0 st2 KITCHEN c 3437 21 153 0.379 6.0 Ox0 VIFx 17.0 115.0 st1 LAUNDRY h 846 42 20 0.361 4.0 Ox0 VIFx 23.3 115.0 st1 M•BATI-FA h 768 58 34 0 0 0x0 VIFx 0 0 wic c 174 3 8 0.309 4.0 Ox0 VIFx 27.0 135.0 st2 Trunk Htg Clg Design Veloc Diann H x W Duct Name Type (cfm) (cfm) FR (fpm) pn) (n) Material Trunk st2 Peak AVF 721 672 0.285 918 12.0 0 x 0 VinlFix st1 st1 PeakAVF 1043 1091 0.285 1020 14.0 0 x 0 VInIF[x � + wrighttsofY 2o17-Apr-11 09:29:38 RlghtSuite® Universal 2017 17.0.14 RSU06101 Page 1 ...uick CaloMDocumenls\THE GRAND CARLTON-1446.mp Calc=MJ8 Front Door faces: N Name Grille Size (in) I Htg (cfm) FCmg) TEL (ft) Design FR Veloc (fpm) Diam (n) HxW (n) StudlJoist Opening (in) Duct Matl Trunk rb1 Ox0 1160 1160 0 0 0 0 Ox 0 VIFx Wrightsoi' 2017-Apr-11 09:29:38 RightS7D Uni versal 1017 77.0.14 RSU08701 Page 2 ...ulck Calcs\Docamnts%TFE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N