HomeMy WebLinkAboutMISC LETTER FROM ARCHITECTONICArchitectonic Inc January 30, 2019 Saint Lucie County Building Department Attn: Roof Permit Plan -Review 2300 Virginia Avenue Ft. Pierce, FL 34982 SCANNED BY St. Lucie County Re: Roofing specification prepared for the St. Lucie County Building Dept. for the structure located at 2427 Atlantic Beach Blvd., Saint Lucie County, Florida Manufacturer: Extreme Metal Fabricators, LLC Profiles: 1" Nail Strip 0.032" Alum. Roof Panel, FL# 17022.6 Code: FBC 2017; Section R 1507.4.2 Wind Speed: 165 MPH; Ultimate Design Wind Speeds Exposure: C Mean Roof Height: 30' Maximum Pitch: 2 /12 Minimum Required Design Pressure: Zone1:30.9 Zone 2:-51.5 Zone 3:-77.3 Maximum Uplift Pressure: 78.5 @ 6" o.c. Row Spacing & Fastener Spacing 16" o.c. Fasteners: #10 x 1" Pancake Head Wood Screw (or of sufficient length to meet 3/16" min. penetration through deck Underlayment: Polyglass Underlayment, FL# 5959-R28(self-adhering) Roof Decking: Existing 5/8" plywood sheathing to be nailed w/8d x 2" ring shank @ 6" D.C. thru out zone 1, 4" O.C. perimeter, and 6" O.C. field zone 2, and 4" O.C. thru out zone 3. The above approved, as per Florida Building Code Compliance acceptances, 2017 Florida Building Code, and the Manufacturer's recommendations. 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1