HomeMy WebLinkAboutMISC LETTER FROM ARCHITECTONICArchitectonic Inc
January 30, 2019
Saint Lucie County Building Department
Attn: Roof Permit Plan -Review
2300 Virginia Avenue
Ft. Pierce, FL 34982
SCANNED
BY
St. Lucie County
Re: Roofing specification prepared for the St. Lucie County Building Dept. for the structure
located at 2427 Atlantic Beach Blvd., Saint Lucie County, Florida
Manufacturer:
Extreme Metal Fabricators, LLC
Profiles:
1" Nail Strip 0.032" Alum. Roof Panel, FL# 17022.6
Code:
FBC 2017; Section R 1507.4.2
Wind Speed:
165 MPH; Ultimate Design Wind Speeds
Exposure:
C
Mean Roof Height:
30' Maximum
Pitch:
2 /12 Minimum
Required Design Pressure:
Zone1:30.9 Zone 2:-51.5 Zone 3:-77.3
Maximum Uplift Pressure:
78.5 @ 6" o.c. Row Spacing & Fastener Spacing 16" o.c.
Fasteners:
#10 x 1" Pancake Head Wood Screw (or of sufficient length to meet
3/16" min. penetration through deck
Underlayment:
Polyglass Underlayment, FL# 5959-R28(self-adhering)
Roof Decking:
Existing 5/8" plywood sheathing to be nailed w/8d x 2" ring shank
@ 6" D.C. thru out zone 1, 4" O.C. perimeter, and 6" O.C. field zone 2,
and 4" O.C. thru out zone 3.
The above approved, as per Florida Building Code Compliance acceptances, 2017 Florida Building
Code, and the Manufacturer's recommendations.
806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com