HomeMy WebLinkAboutTRUSS PAPERWORKA-1 ROOF
_ TRUSSES
A FLORIDA CORPORATION
Lumber design values are in accordance with ANSI/TPI 1-2014 section 6.3
These truss designs rely on lumber values established by others.
RE: Job 75775 r 1 A.1i�oof Trusses
445;�t Lucie Blvd
Site Information:
Fort Pierce, FL 34946
Customer Info: HERITAGE CONSTRUCTION SERVICES Project Name: CLEMONS RESIDENCE
Lot/Block: Model:
Address: 1405 LONE PINE DRIVE, FORT PIERCE 349821ivision:
City: County: St Lucie State: FL SCANNED
Name Address and License # of Structural Engineer of Record, If there is one, for the building. BY
Name: BOWDOIN G. HUTCHINSON License #: 70878
Address: 806 DELAWARE AVE. St. Lucie County
City: FT. PIERCE, FL 34946
General Truss Engineering Criteria Design Loads (Individual Truss Design Drawings Show Special Loading
Conditions):
Design Code: FBC 2017 RES / TPI 2014 Design Program: Alpine Engineered Products
Wind Code: ASCE 7-10 Wind Speed: 160
Rbof Load: 50.0 psf Floor Load: 55.0 psf
This package includes 44 individual, dated Truss Design Drawings and 16 Additional Drawings.
'With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61 G15-31.003,section 5 of the Florida Board of Professional Engineers Rules.
No.
Seq #
Truss Name
Date
No.
Seq #
Truss Name
Date
No.
Seq #
Truss Name
Date
1
10914
FG01
4/11119
13
10942
FL07
4/11119
25
10751
A05G
4/11/19
2
11000
FG02
4/11/19
14
11034
FL07A
4/11/19
26
10625
B01
4/11/19
3
11006
FG03
4/11/19
15
10939
FL07G
4/11/19
27
10636
B02
4/11/19
4
11076
FG04
4/11/19
16
10969
FL08
4/11/19
28
10795
B02A
4/11/19
5
10900
FL01
4/11/19
17
10951
FL09
4/11/19
29
10662
B03
4/11/19
6
10962
FL02
4/11/19
18
10948
FL10
4/11/19
30
11073
B04
4/11/19
7
11040
FL03
4/11/19
19
10918
FL11
4/11/19
31
11064
B05G
4111119
8
10906
FL04
4/11/19
20
10741
A01
4/11119
32
10805
C01
4111/19
9
11070
FL05
4/11/19
21
10757
A02
4/11119
33
10786
CO2
4111/19
10 111067
1
FL05A
4/11119
22
10693
A02A
4/11/19
34
10789
CO2A
4/11/19
11 111028
1
FL05B
4/11/19
23
10763
A03G
4111/19
35
10609
MVA
4/11/19
12
10903
FL06
4/11/19
24
10706
A04
4/11/19
36
10612
MVB
4/11/19
drawing(s) referenced have been prepared byAlpme Erxpneered Products, Inc. under mydirectsuperwslon based on the parameters provided byA-1 RoofTrusses, Lhf.
Truss Design Engineer's Name: Anthony Tombo III
My license renewal date forthe state of Florida is February 28,2021.
NOTE.'The seal on these drawings indicate acceptance of professional engineering
responsibility solelyforthe truss components shown.
al
The suitability and use ofcorrponents forany partiwlarbu7ding Is the responsibility of the building APR 2 2 2019
deslgner,perANSIrrP61 Sec.2
The Truss Design Drawing(s)(rDD[s]) referenced have been prepared based on the constructlo
documents(also referred toattimesas'Stuctuml Engineering Documents'] provided bythe BuO�di gT. Lucie County, PrrP
Designerindicating the natureand characterofthework
The design criteria therein have been transferred to AnthonyTornbo D PEby IA1 Roof Trusses orspecific
location]. These TDDs (also referred to attunes as'Structural Delegated
Engineering Documents) are specialty structural component designs and maybe partof the pmject's
deferred orphaned submittals. As a Truss Design Engmeer(Le, specialty D '�Cz
Englneer),the seal here and on the TDD represents an acceptance ofprofes;Ional engineering Anthony T. Tombo M£� '+211.
responsb0'dyforthe design of the single Truss depicted on the TDD onIK The Building Designerls
responsbleforand shallwordinate and review theTDDs for oz xaw,ln
corrpatibirdywiththelrwdttenenginwringmqubemenM PleasereviewalTDDsandatirelatednotes.
Ir.
NVg1OW :11111
t
4d36b989999e20a51b6cde8e
Page 1 of 2
A16AA-1 ROOF
M TRUSSES
AFLORIOACORPORATION
RE: Job 75775
No.
Seq #
Truss Name
Date
37
10568
MVC
4/11/19
38
10571
MVD
4/11/19
39
10576
MVE
4/11119
40
10579
MVF
4/11/19
41
10582
MVG
4/11/19
42
110588
1 MVH
4/11/19
43
10603
MVJ
4/11/19
44
10600
MVK
4/11/19
45
STDL01
STD. DETAIL
4/11/19
46
STDL02
STD. DETAIL
4/11/19
47
STDL03
STD. DETAIL
4/11/19
48
STDL04
STD. DETAIL
4/11/19
49
STDL05
STD. DETAIL
4/11/19
50
STDL06
STD. DETAIL
4/11/19
51
STDL07
STD. DETAIL
4/11/19
52
STDL08
STD. DETAIL
4/11119
53
STDL09
STD. DETAIL
4/11/19
54
STDL10
STD. DETAIL
4/11/19
55
STDL11
STD. DETAIL
4/11/19
56
STOL12
STD. DETAIL
4/11/19
57
STDL13
STD. DETAIL
4/11/19
58
STDL14
STD. DETAIL
4/11/19
59
STDL15
STD. DETAIL
4111119
60
STDL16
STD. DETAIL
4111/19
Lumber design values are in accordance with ANSI/fPI 1-2014 section 6.3
These truss designs rely on lumber values established by others.
Page 2 of 2
Job Truss Truss Type Dry Ply 04/1012019
75775 I FG01 I FLAT 11 13 I 10914
18,154 SS ttan ZeMs' 18864 Issas
I. 1'3' 1JaB 1TB�Y1�iTBY14'4�Y�1---2�Yt Y•�
14X<(R)
ft4X6 1133<3 m4X4 aXaIR1
t0X10
SEAT PIATE REp.
I^16938p] 1
8 958C 958tl {-fB8>3pIs-
9]3tl1Be 3 {-189]Sb f 9f
Loading Criteria (ps0
Wind Criteria
TCLL: 30.00
Wind Std: ASCE 7-10
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: C Kzt: NA
Des Ld: 50.00
Mean Height: 15.83 ft
NCBCLL. 0.00
TCDL: 5.0 psf
Load Duration: 1.25
BCDL: 5.0 psf
Spacing: 24.0 °
MWFRS Parallel Dist 0 to h/2
C&C Dist a: 3.00 it
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Top chord 2x6 SP 2400f-2.0E :T2 2x6 SP #2:
Bot chord 2x6 SP #2
Webs 2x4 SP #3 :W1 2x8 SP 2400f-1.8E:
:W2 20 SP M-30:
Nailnote
Nail Schedule:0.131"x3", min. nails
Top Chord: 2 Rows @ 3.00" o.c. (Each Row)
Bot Chord: 2 Rows @ 5.00" o.c. (Each Row)
Webs :1 Row @ 4" o.c.
Repeat nailing as each layer is applied. Use equal
spacing between rows and stagger nails in each row
to avoid splitting.
(1)112" bolts may be used for
(2)0.131°x3", min. nails on
Either The Top or Bottom Chords.
Special Loads
---(Lumber Dur.Fac =1.25 / Plate Dur.Fac =1.25)
TC: From 80 plf at 0.00 to 80 pit at 18.00
BC: From 20 plf at 0.00 to 20 plf at 18.00
TC: 1885 lb Cone. Load at 1.25, 9.56,11.56,13.56
15.56.17.56
TC: 2236 lb Conc. Load at 2.63. 7.88
TC: 1189 lb Conc. Load at 4.25, 6.25
BC: 958 lb Conc. Load at 1.71, 3.71, 5.71, 7.60
17.60
BC: 539 Ito Conc. Load at 5.94, 7.94, 9.94,11.94
13.94
BC: 872 lb Conc. Load at 9.60,11.60,13.60,15.60
BC: 804111 Conc. Load at 15.94
Wind
Wind loads and reactions based on MWFRS.
End verticals not exposed to wind pressure.
Code I Misc Criteria
Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
DeffIC81 Criteria
PP Deflection in loc L/de8 L/#
VERT(LL): 0.120 C 999 361
VERT(CL): 0.199 C 999 241
HORZ(LL): 0.027 A - -
HORZ(TL): 0.045 A - -
Creep Factor. 2.0
Max TC CSI: 0.879
Max BC CSI: 0.963
Max Web CSI: 0.977
Wgt: 491.41bs
VIEW Ver. 18.02.01A.0205.20
Pudins
In lieu of structural panels or rigid Ceiling use puriins
to laterally brace chords as follows:
Chord Spacing(In oc) Stari(ft) End(ft)
BC 120 0.00 18.00
Apply pudins to any chords above or below fillers
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- I Rh I Rw I U / RL
L 15029 /• I• /- 15309 !-
M 16704 /- I- /- /5900 !-
Wind reactions based on MWFRS
L Big Width = 6.3 Min Req = 5.9
M Big Width = 8.0 Min Req = 6.6
Bearings L & M are a rigid surface.
Bearings L 8 M require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A - B 1226 -3474 D - E 1614 "-4572
B - C 1614 -4572 E - F 1257 -3562
C - D 1614 -4572
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
at 24' OC unless shown otherwise above.
L - K
0 0
I - H
3719 -1314
The TC of this truss shall be braced with attached spans at
24" o I Jlieu o 1286
T.
H - G
0 0
structural sheathing.
-1286
Blocking
Maximum Web Forces
Per Ply (Ibs)
Full Height Blocking reinforcement required to
Webs
Tens.Comp.
Webs
Tens. Comp.
prevent buckling of members over the bearings:
A- L
1716 -4827
I - E
1401 -493
bearing 1located at 0.00'
A-K
5353-1890
E-H
1051 -2897
Additional Notes
K-B
1100-3034
H-F
5490 -19M
Truss must be installed as shown with top chord up.
B - I
1534 -539
F - G
1793 -5045
C-1
485-1318
"WARNING" Please ftmughly reviewthe-A-1 ROOF TRUSSES('SELLER'), GENERALTERMS and CONDITIONS CUSTOMER
Velf(y design earameters end read notes on Nis Truss Design Drawing (TDD) and the Antheny T. Tombo ill, P.E. Rsferenca Sheet before use. U
use
h,uMOHM WNrvn Tnwnnan mmucelrn MM1 Rmf Tnee-MIMnvT.T=hn III. PE.
AA-1 RDOF
TRLLS5E5
Anthony T, Tombo III, P.E.
# 80083
4451 St. Lucie Blvd.
Fort Pierce, FL 34946
Job
75775
Truss Truss Type
FG02 I FLAT
1ty I PI
Y 04/10/2019
11000
T
io
1
1876# 1876 1876# 1876 1876# 1876 1876#
2'1 "12 ,---�— 2' — -- 2' -- -- 2' — -- 2' -- --_ 2' _ 2' �� 1'tY-1
=4X8
=4X4
III1.5X4 =4X4
=4X8
1114X6 =bxlU =4xi3 =Jxlu =4xts =anlu U
1114X6
SEAT PLATE REQ.
Loading Criteria (pan
Wind Criteria
TCLL: 40.00
Wind Std: NA
TCDL: 10.00
Speed: NA mph
BCLL: 0.00
Enclosure: NA
BCDL: 5.00
Category: NA
EXP: NA Kzt: NA
Des Ld: 55.00
Mean Height: NA ft
NCBCLL: 10.00
TCDL: NA psf
Load Duration: 1.00
BCDL: NA pat
Spacing: 24.0"
MWFRS Parallel Dist: NA
C&C Dist a: NA It
Loc. from endwall: NA
I: NA GCpi: NA
Wind Duration: NA
Lumber
Top chord 2x6 SP 2400f-2.OE
Bot chord 2x6 SP 2400f-2.0E
Webs 2x4 SP M-30 :W1 2x8 SP 2400f-1.8E
:W3 2x4 SP #3:
Nallnote
Nail Schedule:0.131"x3", min. nails
Top Chord: 2 Rows @ 2.50" o.c. (Each Row)
Bot Chord: 1 Row @12.00' D.C.
Webs : 1 Row @ 4" D.C.
Repeat nailing as each layer is applied. Use equal
spacing between rows and stagger nails in each row
to avoid splitting.
(1)1/2' bolts may be used for
(2) 0.131"x3", min. nails on
Either The Top or Bottom Chords.
Special Loads
—(Lumber Dur.Fac. 1.001 Plate Dur.Fac.=1.00)
TC: From 100 plf at 0.00 to 100 plf at 15.10
BC: From 10 pit at 0.00 to 10 plf at 15.10
TC: 1876lb Conic. Load at 2.15, 4.15,,6.15, 8.15
10.15,12.15,14.15
Code I Misc Criteria
Code: FBC 2017 RES
TPI Sid: 2014
Rep Factors Used: Yes
FT/RT:1O(0V10(10)
Plate Type(s):
WAVE
15'1 "4
Deb/CSI Criteria
PP Deflection in loc Udell Lf#
VERT(LL): 0.283 D 639 48i
VERT(CL): 0.390 D 465 36�
HORZ(LL): 0.046 A - -
HORZ(TL): 0.064 A - -
Creep Factor. 2.0
Max TC CSI: 0.490
Max BC CSI: 0.695
Max Web CSI: 0.938
Wgt: 315.0lbs
VIEW Ver. 18.02.01A.0205.20
Additional Notes
Truss must be installed as shown with top chord up.
Purllns
In lieu of structural panels or rigid ceiling use pudins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.00 15.10
Apply pudins to any chords above or below fillers
at 24" OC unless shown otherwise above.
The TIC of this truss shall be braced with attached spans at 24" oc in lieu of
structural sheathing.
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ I R- I Rh / Rw 1 U ! RL
N 6879 I- 1- !--
O 7912l-
N Brg Width = 7.3 Min Req = 1.9
O Brg Width = 6.0 Min Req = 2.2
Bearings N & O are a rigid surface. _
Bearing N requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 0-49M D-E 0 -8921
B-C 0-7860 E-F 0 -7924
C-D 0-8921 F-G 0 -5068
Maximum Sot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
N- M 223 0 K- J 8231 0
M- L 5489 0 J -1 5643 0
L-K 8182 0 I-H 251 0
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
A-N
0-2124
D-K
0 -709
A-M
5051 0
E-J
0 -1140
M- B
0 -2074
J- F
2553 0
B-L
2654 0
F-I
0 -2132
L-C
0-1194
I-G
5168 0
C-K
815 0
G-H
0 -2462
K - E
761 0
"WARNING" Please thoroughly review ere-A-1 ROOF TRUSSES("SELLER'), GENERAL TERMS and CONDITIONS CUSTOMER('aUYER) ACKNOWLEDGMENT font.
erilydesign parameters and read notes on Wariness Design Dree ng (TOD) and the An Mwy T. Tomho III, P.E. Reference Sheet before use. Unless oNenalse stated on Me TDD, only Air
erred., pates shell be used for the TOD W be valid. M a Truss Desion Enalmodm fl.e. SDecialw Enalneer). Me seal m anv T00 represents en acceotanm of Me professional engineer
In the center of Me IRC. Me IBC. loyal buddina rude and TPI4. The
tm+FtrAMWMedIM Wm,vcW ~RWTnu—Mlh+""T. TmmM III. P.E.
A-1 ROOF
TFI 5 ETii
Anthony T. Tombo III, P.E.
# 80083
4451 St. Lucie Blvd.
Fort Pierce. FL 34946
Job
75775
Truss Truss Type I'll
Ply
FG03 I FLAT I 1 12
04/10/2019
11006
Loading Criteria (pq
TCLL: 40.00
TCDL: 10.00
BCLL: 0.00
BCDL: 5.00
Des Ld: 55.00
NCBCLL: 10.00
Load Duration: 1.00
Spacing: 24.0 "
T
SO
1883# 1872# 2129##
F611� 2 1872 2 2' 1872 1'10"12 414
1114Y�4(R) 1111LM 1114X64(R)
3 =4X10 =3X10 =4X10
Wind Criteria
Wind Sid: NA
Speed: NA mph
Enclosure: NA
Category: NA
EXP: NAKzt: NA
Mean Height: NA It
TCDL: NA psf
BCDL: NA psf
MWFRS Parallel Dist: NA
C&C Dist a: NA It
Loc. from endwall: NA
1: NA GCpi: NA
Wind Duration: NA
Lumber
Top chord 2x6 SP 240oF2.OE
Bot chord 2x6 SP 24001-2.0E
Webs 2x4 SP M-30:W1 2x6 SP #2:
03 2x4 SP #3:
Nailnote
Nail Schedule:0.131"x3', min. nails
Top Chord: 2 Rows @ 2.00" o.c. (Each Row)
Bot Chord: 1 Row @12.00' o.c.
Webs : 1 Row @ 4" o.c.
Use equal spacing between rows and stagger nails
in each row to avoid splitting.
(1)1/2" bolts may be used for
(2) 0.131"x3", min. nails on
Either The Top or Bottom Chords.
Special Loads
—(Lumber Dur.Fac. 1.00/ Plate Dur.Fac. 1.00)
TC: From 100 plf al 0.00 to 100 plf at 8.83
BC: From 10 plf at 0.00 to 10 plf at 8.83
TC: 1883 Ib Conc. Load at 0.54
TC: 1872 Ib Conc. Load at 2.54, 4.54, 6.54
TC: 2129 lb Gone. Load at 8.44
Code / Misc Criteria
Code: FBC 2017 RES
TPI Sid: 2014
Rep Factors Used: Varies by Ld
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
8'1011
Defl/CSI Criteria
PP Deflection in too Udell L#t
VERT(LL): 0.070 C 999 48
A-:RT(CL): 0.097 C 999 36
HORZ(LL): 0.014 A - -
HORZ(TL): 0.019 A - -
Creep Factor. 2.0
Max TC CSI: 0.263
Max BC CSI: 0.413
Max Web CSI: 0.662
Will: 114.8 lbs
VIEW Ver. 18.02.01A.0205.20
Truss must be installed as shown with top chord up.
Purlins
In lieu of structural panels or rigid ceiling use purilns
to laterally brace chords as follows:
Chord Spacing(m oc) Stad(fl) End(ft)
BC 106 0.00 8.83
Apply purling; to any chords above or below fillers
at 24' OC unless shown otherwise above.
The TC of this truss shall be braced with attached spans at 24" oc in lieu of
structural sheathing.
"WARNING^ Please thoroughly review the -A-1 ROOF TRUSSES
edfy design Parameters and read notes on this Truss Design Drawing (TDr
vmeGor plates shall be used forNe TDD to be valid. AsaTmss DesignE
sponslGllity for[he tlesign M [na sirele Truss deoltled on Ne TOD eNv. on
All ppilalbod m ms are m dented In WiFl.
Is PE. RmM,vlm NMixhnmN.lnmvlmm.
♦Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- 1 Rh / Rw / U / RL
J 5077 /- /-!-
K 5522 /- I-/-
J Brg Width = 6.0 Min Req = 2.1
K Brg Width =8.0 Min Req=2.3
Bearings J & K are a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 0-3358 C-D 0 -4630
B-C 0 -4630 D-E 0 -3379
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
J-1 71 0 H-G 3850 0
I-H 3825 0 G-F 74 0
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
A-J
0-2406
H-D
889 0
A-1
3631 0
D-G
0 -1745
1-8
0-1732
G-E
3651 0
B-H
917 0
E-F
0 -2626
C-H
0 -8W
3AL TERMS and CONDITIONS CUSTOMER (°BUYER°) ACKNOWLEDGMENT fo,m.
Tambo 111. RE Reference Sheet before use. Unless eUmry stated on the Too. only All
illy Emmert. the seal on any Too renresents an am.,ntanen of Me nmfaeannnl Anninnen
1-1 defines the responsibdifies and duties of to T
Involved. The Tmss Design Engineer is NOT the
A-1 RMTnyy^e-ATfimvT. T=M lit. PE
e
Anthony T. Tombo III, P.E.
# 80083
4451 St. Lucie Blvd.
Foil Pierce, FL 34946
Job
75775
Truss
FG04
Truss Type
MONO
1ty 12y I U4/11r2U19
11076
Loading Criteria (psq
TCLL: 40.00
TCDL: 10.00
BCLL: 0.00
BCDL: 5.00
Des Ld: 55.00
NCBCLL: 10.00
Load Duration: 1.00
Spacing: 24.0 "
T
1
J
Wind Criteria
Wind Std: NA
Speed: NA mph
Enclosure: NA
Category: NA
EXP: NAKzt: NA
Mean Height: NA It
TCDL: NA psf
BCDL: NA psf
MWFRS Parallel Dist: NA
C&C Dist a: NA It
Loc. from endwall: NA
I: NA GCpi: NA
Wind Duration: NA
Lumber
Top chord 2x6 SP 2401
Bot chord 2x6 SP 2400f-2.0E
Webs 2x4 SP #2 :W1 2x6 SP #2:
:W3 2x4 SP #3:
1897
#-- 189 # 18 #
=dx4 1111 Fxd =4X4
8'3"8
7'10"4
200#
Naiinote
Nail Schedule:0.131"x3°, min. nails
Top Chord: 2 Rows @ 3.00" o.c. (Each Row)
Bot Chord:1 Row @12.00'o.c.
Webs : 1 Row @ 4° o.c.
Use equal spacing between rows and stagger nails
In each row to avoid splitting.
(1) 1/2' bolts may be used for
(2)0.131"x3°, min. nails on
Either The Top or Bottom Chords.
Special Loads
—(Lumber Dur.Fac =1.00 / Plate Dur.Fac=1.00)
TC: From 100 plf at 0.00 to 100 plf at 8.29
SC: From 10 plf at 0.00 to 10 plf at 8.29
TC: 958 lb Cone. Load at 0.44
TC: 1897 lb Gone. Load at 2.44, 4.44, 6.44
BC: 200 lb Come. Load at 0.44
Code I Misc Criteria
Code: FBC 2017 RES
TPI Sid: 2014
Rep Factors Used: No
FT/RT:10(0v10(10)
Plate Type(s):
WAVE
DefIICSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.057 C 999 48(
VERT(CL): 0.079 C 999 36(
HORZ(LL): 0.011 A - -
HORZ(TL): 0.015 A - -
Creep Factor. 2.0
Max TC CSI: 0.252
Max BC CSI: 0.354
Max Web CSI: 0.864
Wgt: 114.8 Ibs
VIEW Ver. 18.02.01A.0205.20
Truss must be installed as shown with top chord up.
Puffins
In lieu of structural panels or rigid ceiling use puffins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 99 0.00 8.29
Apply pudins to any chords above or below fillers
at 24' OC unless shown otherwise above.
The TC of this truss shall be braced with attached spans at 24' oc in lieu of
structural sheathing.
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity -
Loc R+ / R- / Rh / Rw / U / RL
J 4198 1- !- /- /- /-
K 3563 I-l-
J Big Width = 6.0 Min Req = 1.7
K Brg Width = 5.5 Min Req = 1.5
Bearings J 8 K are a rigid surface. _
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 0-2798 C-D 0 -3922
B-C 0-3922 D-E 0 -2796
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
J-1 59 0 H-G 3212 0
I- H 3206 0 G- F 59 0
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
A-J
0-1895
H-D
824 0
A-1
3062 0
D-G
0 -1541
I-B
0-1515
G-E
3060 0
B-H
830 -35
E-F
0 -1654
C-H
2 -825
"WARNING" Please thoroughly revlew the Wil ROOF TRUSSES("SELLER-), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER') ACKNOWLEDGMENT' farm.
reriry design peremetars and mad noteson this Truss Design Drewing Crop) and the Anthony T. Tombo III, P.E. Reference Shoot before use. Unless athenvise stated an the TDD, onlyA;
cmredarplatesshallbeuwdfarthe TDDtobevalid. Asa Truss Design EnginmAng(x.spedalty Engineer),thesealmany TDDrepresentsana=ptanmofthepee onalengineer)
asponsibility for the design of the single Tmss dWicted an the Too only, under TPl-1. The design assumptions, loading opntlNons, suitability and use of this Truss fumy Building Is rue
Nllding a Me responsibilityofthe Owneg the Oxmets authorized agent orthe Building Designer, In the mntea of the IRC, the IBC, local building wtle and TFIA. Theapprovalofthe
esponsibillry of the Owner, the Owners euMarlzed agent or the Building Designer. in the cordso ofthe IRC, the IBC, brat building code and TPI-l. Theapprovalottha TDDandanygeld
se arwre Tmss, Induding la ndling, suaage, installation and bracing shall bathe responsibilily of the Building Designerard Coneedar. All notes set out in the TDD end the practices end
uldelines ofthe Building Component Safety Intonnedon(BSCI) published by TPI and SSCA are referenced for general guvJanos. TP4ldefina eresponbiligwwddWe ofthe True
bsigner, Truss Design Englneerand Truss Manufacturer, unless athenow defined by a Contract agreed upon In writingbyall pandas Invohetl. The Truss Design Engineer is NOT the Buih
Iazylner or Tian System Engineer of any buildlrg. All ®Wlarmetl terms are as defined in TPI-l.
gym", 0201e MI RmITn¢ara-MMmvT. T—ho III. P E. WmMrrlmdvr.. rnt'vr—mon.. noon..., I... wmLNm all WW1in-MawivT. TanM In. PE.
A#�"UME5
Anthony T. Tombo III, P.E.
# 80083
4451 St. Lucie Blvd.
Fort Pierce, FL 34946
Jab ITruss Truss Type City Ply 04/10/2019
75775 FL01 I SY42 14 I 1
10900
~2c16YPj
—710'8 1 10' 1 17'9° •} 2N9'i 26'1018i 34.10.8 -�
-1.SX4(R) sei
3'1 AF
m
-3X6
SEAT PLATE REQ.
C
-3X3 -3X4
D E
W=3X6 -4X8
F G H
02X4 -3X10 W=3X6
I J K L
=3X4 -3X3
M N
O
-3X6-1.5X4(
P OR
AD
AC AS
AA Z
YM X W
V U
T
-3X8
-3X10
-4X10 W=3X6
-3X8
-3X6
W=3X6
-4X8
34'10'8
SEAT PLATE REG.
16'11'4 JA
Loading Criteria (ps0 Wind Criteria
Code / Misc Criteria
Deg/CSI Criteria
A Maximum Reactions (Ibs)
TCLL: 40.00 Wind Sid: NA
Code: FBC 2017 RES
PP Deflection in loc Udell L/#
Gravity Non -Gravity
TCDL: 10.00 Speed: NA mph
TPI Std: 2014
VERT(LL): 0.272 AC 780 48
LOG R+ I R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: NA
Rep Factors Used: Yes
VERT(CL): 0.369 AC 575 36
AE 903 /- /-/-
BCDL: 5.00 Category: NA
FT/RT:10(Ov10(10)
HORZ(LL): 0.046 S - -
Y 2138 1- l-l-
EXP: NAKzt: NA
Des Ld: 55.00
Plate Type(s):
HORZ(TL): 0.062 S - •
S 860 /- /- A
Mean Height: NA ft
WAVE
Creep Factor. 2.0
AE Br Width = 7.3 Min Re = 1.5
9 q —
NCBCLL: 10.00 TCDL: NA psf
MaxTCCSI: 0.891
Y Brg Width=4.0 Min Req=1.5
Load Duration:4.01.00 NA psf
S Brg Width = 7.3 Min Req = 1.5
Spacing: MWFBCD
Spacing: 24.0 ° MWFRS Parallel Dist: NA
Max BC CSI: 0.800.
Bearings AE, Y, & S are a rigid surface.
C8C Dist a: NA It
Max Web CSI: 0.716
Max
AE & S require a seat plate.
Lac. from endwall: NA
Wgl: 189.0 Ibs
Maximum Top Chord Forces Per Ply (Ibs)
I: NA Gatio NA
Chords Tens.Comp. Chords Tens. Comp.
- Wind Duration: NA
VIEW Ver. 18.02.OtA.0205.20
Lumber
A-B 0 0 1-1 1540 0
Top chord :T24x2 SP#2:
B-C 0-2337 J-K 183 -1513
rd4x2SPM-30
gotC-D
chord 4x2 SP M•30:B24x2 SP#2:
0-2337 K-L 183 -1613
We
Webs 4x2 SP #3
D-E 0-2603 L-M 183 -1513
E-F 0-1910 M-N 0 -2329
Plating Notes
F-G 0-1910 N-O 0 -2184
All plates are 1.5X4 except as noted.
G-H 0-1910 O-P 0 -2184
H-1 1540 0 P-Q 0 0
Puffins
In lieu of structural panels or rigid ceiling use puriins
Maximum got Chord Forces Per Ply (Ibs)
to laterally brace chords as follows:
Chords Tens.Comp. Chords Tens. Comp.
Chord Spacing(in oc) Starl(ft) End(ft)
B120 0.19 34.69
AE-AD 1432 0 Y-X 289 -637
Applyy to any chords shove or below fillers
AD -AC 2605 0 X-W 289 -637
OC unless
at 24' OC unless shown otherwise above.
AC -AB 2603 0 W - V 2324 0
AB -AA 2599 0 V - U 2329 0
Additional Notes
AA-Z 756 -328 U-T 2332 0
+ 2x6 Continuous strengback.
Z-Y 756 -32B T-S 1352 0
Truss must be installed as shown with top chord up
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
AF-AE
0 -117
Y-J
0 -1479
A-AF
0 -106
J-W
1504
0
AE-B
0-1625
K-W
30
-269
B -AD
1027 0
W- M
0
-1128
C-AD
0 -319
M-V
225
0
AD-D
155 -509
U-N
35
-187
D-AC
66 -161
N-T
258
-379
AS-E
195 -31
O-T
0
-329
E-AA
0-1017
T-P
944
0
G-AA
22 -275
P-S
0
-1535
AA-H
1408 0
Q-R
0
-10B
H-Y
0-1989
S-R
0
-6
I-Y
0 -249
R-S
0
-112
"WARNING" Please thoroughly review lhe'A-1 ROOF TRUSSES("SELLER'), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER') ACMOWLEDGMENP form.
e
'eriy design parametersend reatl na% on this Truss Design Dmwing(TDO) and the Anthony T. Tombo ill, P.E. Reference Sheetbefore use. Unless otherwise stated an the TOD, onlyAlpin
onne mplatesshallbeusedfwthe TDDtobevefd. As a Truss Design Engineering i.e. Spedaly Engineer), the seal on any TOO represents an acceptance M the professional engineedn
nponsollityfor the design ofthe single Truss derided on the TOO orsy, under TPI-1. The design assumptions, reading conditions, sultabmy and use ofglis Truss for any Building is Via
Aq ROOF
uilding is the responsibility of the Owner. the Owne(s authorized agent crthe Building Designer. In the cenmAcd the IRO, the IBC. brat building code and TP1-1. Theappmvalofthe
TR055E$
rsponslbiliyoftbs Ow r.the Ownahauthorizad agentorUm Building Dasigner,inNeconteatoftha IRC, lire ISO, ran[ building code and P]A. TheapPmvaloftha TDDandanyrreld
the Tress, including handling,
on y
Anthony•Tombo ill. P.E.
se of storage, Installation and bracing shall be the msponsibiliry of the Building Designer and Contractor. All notes sat out in lira TDD and the pmctices end
addines ofthe Building Competent Safety Information (SSCI)pubilshed by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties blithe Truss
480083
esgner, Truss Design Engineer and Truss Maneachaer, unless otherwise defined bya Conrad agreed upon In wrlfing by all series lmohed. The Tmss Design Engineeris NOT the Buildir
g 4451 St. Lucie Blvd.
esigner"Truss System Erglneer of any builOhg. At mpltaOTed I. ere ea defined in TPI-1.
nn YitO'M1fi A1aMTnwuu-MHmvT. TrmMn1. P.E. amv,WN'um ANiahnvrvint mwrvfrun.krurAlhOrtl WMnd Nnwlnen ramJUNnNA.1PMTn�va-MPmvT T,vnM I11. P.E.
Fort Pierce, FL 34946
Job Truss Truss Type City Ply 04/11/2019
75775 FL02 SY42 14 11 0962
T10'8 I to, 1 177 I 24'11'4 I27'0'121 34'11"4
m 1.SX4(R) =4X6 =3X3 sa3X4 W=3X6 =4X8 012X4 =3X10 W=3X6 a33X4 a3X3 =3X6
EA B C D E F G H I J K L M N O isQ
F3 71-1 A
ADI I AC AB AA Z V
ee3X6 m3X8 =3X10 e
W=3X6
SEAT PLATE REO.
17'11'4
f 34'1
Loading Criteria tpso Wind Criteria
TCLL: 40.00 Wind Sid: NA
TCDL: 10.00 Speed: NA mph
BCLL: 0.00 Enclosure: NA
BCDL: 5.00 Category: NA
EXP: NAKzt: NA
Des Ld: 55.00 Mean Height: NA it
NCBCLL: 10.00 TCDL: NA psf
Load Duration: 1.00 BCDL: NA psf
Spacing: 24.0MWFRS Parallel Dist: NA
CSC Dist a: NA it
Lob. from endwall: NA
I: NA GCpb NA
Wind Duration: NA
Lumber
Top chord 42 SP M-30 :T2 4x2 SP #2:
Bot chord 42 SP M-30 :B2 4x2 SP #2:
Webs 4x2 SP #3
Plating Notes
All plates are 1.5X4 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purling
to laterally brace chords as follows:
Chord Spacing(in oc) Start(fl) End(it)
BC 120 0.19 34.94
Apply pudins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Additional Notes
+2x6 Continuous strongback.
Truss must be Installed as shown with top chord up.
Code / Misc Criteria
Code: FBC 2017 RES
TPI Sid: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
"WARNING" Please thoroughly re'Aew the 'A-1 ROOF TRUSSES
'erify design parameters and mad notes on this Truss Design Ordwing CME
onnestor plates shall be used for the TOD to he valid. As a Truss Deal S
ss,nmability for the design of the single Truss deploted on the TOD only, on
Wilding Is the res,umsbilily, of the Ovmer, the Owners authorized agent or
W V U T S R
W=3X6 m3X8 =3X6
=4X8
17'
DeflICSI Criteria
PP Deflection in Too Udall L/#
VERT(LL): 0.272 AS 779 48
VERT(CL): 0.369 AS 575 36
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity -
Loc R+ / R- / Rh l Rw I U 1 RL
AD 901 1--
HORZ(LL): 0.046 R - -
X 2158 /-l-
HORZ(TL): 0.063 R - -
R 863 I -/-
Creep Factor. 2.0
AD Brg Width = 7.3
Min Req = 1.5
Max TCCSI: 0.919
X Brg Width =4.0
Min Req =1.5
Max BC CSI: 0.805
R Brg Width =-
Min Req = -
Max Web CST: 0.714
Bearings AD 8 X are a rigid
surface.
Wgl: 186.2 Ibs
VIEW Ver. 18.02.01A.0205.20
GENERAL TERMS and CONDITIONS CUSTOMER
cony T. Tombo III, P.E. Referents, Sheet before use. U
Spedally Engineer), the seal many TOD represents t
deslon ea.marsons. loading mndilioea. suitabilhv and
Searing AD requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
—A-B
0 0
1-1
1577 0
B-C
0-2329
J-K
156 -1588
C-D
0-2329
K-L
156 -1588
D-E
0-2588
L-M
156 -1588
E- F
0 -1888
M- N
0 -2393
F-G
0-1888
N-O
0 -2237
G-H
0-1888
O-P
0 -2237
H-1
1577 0
P-Q
0 0
Maximum But Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
AD -AC
1427
0
X-W
369
-610
AC -AB
2590
0
W - V
369
-610
AB -AA
2588
0
V - U
2388
0
AA- Z
2584
0
U- T
2393
0
Z- Y
731
-372
T- S
2396
0
Y- X
731
-372
S- R
1400
0
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Coni Webs Tens. Camp
AE-AD
0 -117
I-X
0
-259
A-AE
0 -106
X-J
0
-1590
AD- B
0 -1620
J- V
1498
0
B-AC
1023 0
K-V
29
-270
C-AC
0 -320
V-M
0
-1123
AC- D
164 -501
M - U
224
-1
D-AB
65 -163
T-N
38
-186
AA-E
198 -29
N-S
255
-395
E-Z
0-1027
O-S
0
-328
G- Z
22 -275
S- P
950
0
Z-H
1415 0
P-R
0
-15W
H-X
0-1992
Q-R
0
-109
parties Involved. The Truss Design Engineer is 1
h &Y lP Tnn a-4MMnvT. Thrihn ln. PE_
farm.
dy Alpi
L 5E5
s,
9T
one
Anthony T. Tombo ill, P.E.
rinse
# 80083
Build!
4451 St. Lucie Blvd.
Fart Pierce. FL 34946
Job Truss Truss Type City Ply 04/11/2019
75775 I FL03 I SY42 11 11
11040
r4-
r4-
f-3•—{?,T.4�-
IT34 iT146
� r 33'6'e
'141-4
a3X3
1=1.5X4(R)
W=3X6 W=3X6
03X3
A B C D E
F G H I J K L M N OP O R S T U V W X Y
Z AA AB AC AD
3'1 BI
BH BIG SF BE BD
BC BS BA AZ AY AXAWAV AUATAS AR AQAPAO AN AM AL AK AJ
AI AH AG AF A
Ilf(R) e3X3
W=3X6 W=3X6
103X3
SEATPLATEREO.
34'11'4
Loading Criteria Msri
Wind Criteria
Code l Misc Criteria
TCLL: 40.00
Wind Sid: NA
Code: FBC 2017 RES
TCDL: 10.00
Speed: NA mph
TPI Sid: 2014
BCLL: 0.00
Enclosure: NA
Rep Factors Used: Yes
BCDL: 5.00
Category: NA
FT/RT:10(0)/10(10)
EXP: NAKzt: NA
Plate Type(s):
Des Ld: 55.00
Mean Height: NA R
WAVE
NCBCLL: 10.00
TCDL: NA psf
Load Duration: 1.00
BCDL: NA psf
Spacing: 24.0
MWFRS Parallel Dist: NA
C&C Dist a: NA it
Loc. from endwall: NA
I: NA GCpi: NA
Wind Duration: NA
Lumber
Top chord 4x2 SP #2
Bot chord 4X2 SP #2
Webs 4x2 SP #3
Bracing
Sheathing is required for any longitudinal(dmg) farces. All connections to be
designed by the building designer.
Plating Notes
All plates are 1.5X4 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use puffins
to laterally brace chords as follows:
Chord Spacing(In oc) Stad(ft) Enil
BC 120 0.19 34.94
Apply pudins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Additional Notes
Truss must be installed as shown with top chord up.
DeflICSI Criteria
♦ Maximum Reactions (Ibs), or •=PLF
PP Deflection in loc Udefl
L#f Gravity
Non -Gravity
VERT(LL): 0.000 AD
999 48 Loc R+ / R- / Rh
/ Rw / U
/ RL
VERT(CL): 0.000 AD
999 361 AE•109 /- /-
P!-
HORZ(LL): 0.000 AD
- - AE Brg Width = 419
Min Req = -
HORZ(TL): 0.000 AD
- - Beating BH Is a dgid surface.
Creep Factor. 2.0
Bearing BH requires a seat plate.
Max TC CSI: 0.124
Maximum Top Chord Forces Per Ply (Ibs)
Max BC CSI: 0.028
Chords Tens.Comp.
Chords Tens. Camp.
Max Web CST: 0.032
A-B 0 0
P-Q
0
0
Wgt: 186.2 lbs
B-C 6 0
Q-R
0
0
C-D 0 0
R-S
0
0
VIEW Ver. 18.02.01A.0205.20 D-E 0 0
S-T
0
0
E-F 0 0
T-U
0
0
F-G 0 0
U-V
0
0
G-H 0 0
V-W
0
0
H-1 0 0
W-X
0
0
1-1 0 0
X-Y
0
0
J-K 0 0
Y-Z
0
0
K-L 0 0
Z-AA
0
0
L-M 0 0
AA -AB
0
0
M- N 0 0
AB -AC
6
0
N-O 0 0
AC -AD
0
0
O-P 0 0
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
BH-BG
0
0
AS -AR
0
0
BG-BF
5
0
AR-AQ
0
0
BF -BE
0
0
AQ-AP
0
0
BE -BD
0
0
AP -AO
0
0
BD -BC
0
0
AO -AN
0
0
BC -BB
0
0
AN -AM
0
0
BB -BA
0
0
AM -AL
0
0
BA -AZ
0
0
AL -AK
0
0
AZ -AY
0
0
AK-AJ
0
0
AY-AX
0
0
AJ-AI
0
0
AX-AW
0
0
AI-AH
0
0
AW-AV
0
0
AH-AG
0
0
AV -AU
0
0
AG-AF
6
0
AU -AT
0
0
AF-AE
0
0
AT -AS
0
0
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
BI-BH 0 -59 AG -AC 0 -18
A-BI 0 -48 AD-AE 0 -45
"WARNING" Please thoroughly review the`A-1 ROOFTRUSSES('SELLER'), GENERALTERMS and CONDITIONS CUSTOMER(°BUYER")ACKNOW_EDGMENr form.
edfyrisagn pamrretersand read notes on Ibis Truss Design Growin;(TDD) and tie Aaftn T.Tomb, ill, P.E.Referenm Sheet before use. Unless aNervAse stated on Ne TOD, only Npin
mneMrplatesshallbeusedfor NeTDWbe lid. Marron Design Erginewagile. Specialty Engineer), Mussel on amy TOD represenow, eewptanceof NepMessionatangles A4 ROOF
sponsi tityfor the design of Me single Truss depicted onto Too only, under TPI.1. The design assumptions, loading conditions, suitability and use of this Truss for any Buildingis Me �TRO55E5
wlding is Me responsibility&the Owner, the OwnelsauMer4edagentor Me Building Designer, in the earlextofte,IRC. Me IBC, local building oaduand TPl-1. Truer, valor Ma
eaponsibllity of Me Owner, Me Ow,ear's authorized agent onto Building DnIgner, MO. contextof the IRC, the IBC, local bulling code and TPI-1. The appmJdl of Ne TOD and anyfleld
as oflhe Truss, In,Juding hendrug,storage, installation and bmtlrg shall be Me respossItatity of Me Sutding Designer and Canrecter. Alirlotessetp hMe TDDand Mepmtll send Anthony T. Tombo ill, P.E.
uiddlnesof Me Building Component Saretylnformagon(BSCI)pubishedby TPiand SBCAAmmfemncedfargenemlguidance. TPI-1 defines Me mi,onsibilides and Man ofdle Truss #80083
augow, Truss Design Engineerand Truss Manufacturer. unless othentise derided bya Contract agreed upon In wtlting by all parties lnvotoed. Thu Tmss Design Engiaceris NOT1he Burdi 44$1 St. Lucia Blvd.
esigneror Truss S,stem EaMr.erofanybulding. Alleapnalixedtermsareesdernedln TPl-1.
novnnl,lOaela p-1RMTn¢we-ANI,nry T.TmmMIIL PE. RwWlzsmnfffh LnmwM1 M v awn. d oMniM WWANn uMv, mini Xl RMTrnc -p vT. T=MIn PE- Fort Plerm. FL 34946
Truss Truss Type
FL03 I SY42
Qty Pry 0411/2019 11040
1 1 '
i
B-BF 0 -17
"WARNING" Please thamugNy review line-A-1
TERMS and CONDmONS
use.
Maximum Gable Forces Per Ply (Ibs)
Gables Tens.Comp. Gables Tens. Comp
BG-B
0 -125
P-AS
0
-77
BF-C
0 -128
Q-AR
0
-137
D-BE
0 -135
R-AQ
0
-133
E-BD
0 -133
S-AO
0
-133
F-BC
0 -133
T-AN
0
-133
G-BB
0 -133
V-AM
0
-133
H-BA
0 -133
W-AL
0
-133
1-AZ
0 -133
X-AK
0
-133
K-AY
0 -133
Y-AJ
0
-133
L-AX
0 -133
Z-AI
0
-133
M -AV
0 -133
AA-AH
0
-135
N-AU
0 -137
AB -AG
0
-124
O -AT
0 -77
AC-AF
0
-137
ACIW0WLEOGMENT form.
r refersnoeiforgenerslguidarwe. TPI-1degnae NerespansibWJesenddutles
Id agreed upon In wsigng by all panes Involved. Tie Twss Design Engll risI
p mNtiMM u fl fna"smn.,nxw,NA-1 Rm Tnu-MMnnvT. Tn III, P E.
r
A-1 ROOF
�TR055F5
Anthony T. Tombo III, P.E.
# 80083
4451 St. Lucie Blvd.
Fort Pierce, FL 34946
Job ITruss
75775 IFL04
}— 7'5.12
=3X6
A B
T
=4X4
Loading Criteria (,.q
TCLL:
40.00
TCDL:
10.00
BCLL:
0.00
BCDL:
5.00
Des Ld: 55.00
NCBCLL: 10.00
Load Duration: 1.00
Spacing: 24.0"
Tmss Type
SY42
I- 2'6' --I
(T'!P)
�1 974 ---�
=3X3 =3X4 W=3X6
C D E F G
S R Q P O
=3X8 =3Xl0
W=3X6
Wind Criteria
Wind Bid: NA
Speed: NA mph
Enclosure: NA
Category: NA
EXP: NAKzt: NA
Mean Height: NA ft
TCDL: NA psf
BCDL: NA psf
MWFRS Parallel Dist: NA
C&C Dist a: NA ft
Loc. from endwall: NA
I: NA GCpi: NA
Wind Duration: NA
Lumber
Top chord 4x2 SP #2
Bat chord 4x2 SP #2 :B2 4x2 SP M-30:
Webs 4x2 SP #3
Plating Notes
All plates are 1.5X4 except as noted.
Purlins
In lieu of stmctuml panels or rigid ceiling use pudins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.00 21.31
Apply purling to any chords above or below fillers
at 24' OC unless shown otherwise above.
Code I Misc Criteria
Code: FBC 2017 RES
TPI Sid: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Additional Notes
+ 2x6 continuous strongback.
Negative reaction(s) of -3954 MAX. from a non -wind load case requires uplift
connection. See Maximum Reactions.
Truss must be installed as shown with top chord up.
Qty y 111411012019
4 11
17'4'4 21'6' --{
=3X10 1112X4 =3X4 =-1.5X4(R)
H I J KL 3"1
DegICSI Criteria
PP Deflection in loc Udefl L/#
VERT(LL): 0.265 Q 790 48
VERT(CL): 0.358 Q 585 36
HORZ(LL): 0.043 B - -
HORZ(TL): 0.061 B - -
Creep Factor. 2.0
Max TC CSI: 0.796
Max BC CSI: 0.770
Max Web CSI: 0.627
Wgt: 120.4 Ibs
VIEW Ver. 18.02.01A.0205.20
"WARNING** Please thoroughly review the 'A-1 ROOF TRUSSES("SELLER'). GENERAL TERMS and CONDITIONS CUSTOMER
"design parameters and read notes on Mis Tmss Design Drawing(Too) and Me Anthany T. Tombo ill, P.E. Refemnce Sheet before Mos.0
annector plates shall be used for Me Too to be valid. As a Truss Design Engineering Ike. Specialty Engineer), Me seal on any TDO ropmeords
Tl1'8
10906
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- !Rh /Rw IU IRL
T 872 1- /-
/- /- P
N 1675 A /-
/- I. I-
M 101 /-395 /-
/- I- P
T Brg Width =-
Min Req =-
N Brg Width = 4.0
Min Req = 1.5
M Brg Width = 3.5
Min Req = 1.5
Bearings N & M are a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
Chords Tens. Comp.
A-B 0 0
F-G 0 -1774
B-C 0-2203
G-H 0 -1774
C-0 0-2203
H-1 1197 0
D-E 0-2468
I-J 1197 0
E-F 0-1774
J-K 0 0
Maximum Sot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
T- S 1296 0 P- O 2464 0
S-R 2470 0 O-N 617 0
R- Q 2470 0 N- M 7 -588
Q - P 2468 0
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
A-T
0 -95
O-H
1317
0
T-B
0-1501
H-N
0
-1898
B- S
1030 0
I- N
0
-264
C-S
0 -297
N-J
0
-899
S-D
0 -478
J-M
727
-9
D-Q
63 -123
K-L
0
-81
P-E
158 -28
M-L
0
-6
E-O
0 -820
L-M
0
-86
G-O
3 -274
i ruse. uucmg naming. Manage, mstan2allre auen and abe Me sponsitlity, of Me sulking Designer and Conbactor. Alnotessetout in Me TDDandtlepre
of Me Building Component Safety Mfmreatim(BSCI)IPublished by TPI and SBCA are referencetl for general guidance. T l-ldeFn Meresponsbi4tiesendduti
Truss Design Engineer and Truss Menufacemi, unless othermse derined by a Conlrad agreed upon In unions by all ladies imohred. TheTmss Design Engineou-1 f
m Trues System Engineer Manybuliditg. Al ppilalxetl tails ere as defulM in TPI-i.
)211e M1Rif Tnuye_MM T.TnNnIII. 111 RpuryevNnb Wxhnimmt Naml[um.dryNMI1M u91WdgnynXm rcmJWm N0.1 RrcJTnw"w_Mltunv T.TmYn IIL RE.
101 A-1 RODF
TRU55E5
Anthony T, Tombo III, P.E.
# 80083
4451 St. Lucie Blvd.
Fort Pierce, FL 34946
Job
75775
Truss
FL05
I Was Type City I-ly
SY42 4 1 1
04Itvs0ia
11070
H 3n1
Loading Criteria(psti
TCLL: 40.00
TCDL: 10.00
BCLL: 0.00
BCDL: 5.00
Des Ld: 55.00
NCBCLL: 10.00
Load Duration: 1.00
Spacing: 24.0' ,
I--2-6---I
(TYP)
1111.5X4 =3X8
A B
1.5X4(R)
III1.5X4
1111.5X4 =3X4 =3X4 W=3X4
C D E F G
1T9"11 r{
==3X8 1111.5X4
H I
II� `IM
IMI.%,7'bMhh�
EPP"` `Ili
e _
W=H0308
SEAT PLATE RED.
17711
Wind Criteria
Wind Std: NA
Speed: NA mph
Enclosure: NA
Category: NA
EXP: NAKzt: NA
Mean Height: NA It
TCDL: NA psf
BCDL: NA psf
MWFRS Parallel Dist: NA
CB.0 Dist a: NA ft
Lac. from endwall: NA
I: NA GCpi: NA
Wind Duration: NA
Top chord 4x2 SP #2
Bot chord 4x2 SP 42:B24x2 SP M-30:
Webs 4x2 SP #3
Purlins
In lieu of structural panels or rigid ceiling use puriins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.19 17.81
Apply pudlns to any chords above or below fillers
at 24' OC unless shown otherwise above.
Hangers! Ties
(J) Hanger Support Required, by others
Additional Notes
+ 2x6 Continuous strongbacic
Truss must be installed as shown with top chord up.
Code I Misc Criteria
Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE, HS
De6IC81 Criteria
PP Defection in loc L/defl L/#
VERT(LL): 0.272 M 778 48
VERT(CL): 0.378 M 559 36
HORZ(LL): 0.041 B - -
HORZ(TL): 0.062 B -
Creep Factor. 2.0
Max TC CSI: 0.714
Max BC CSI: 0.889
Max Web CSI: 0.558
Wgb 95.2 lbs
VIEW Ver. 18.02.01 A.0205.20
♦ Maximum Reactions (III
Gravity Non -Gravity
LOG R+ ! R- / Rh / Rw I U I RE
P 977 /- /- /- A P -
J 969/-
P Brg Width = 7.3 Min Req = 1.5
J Brg Width = - Min Req = -
Bearing P is a rigid surface.
Bearing P requires a seat plate.
Maximum Top Chord Forces Per Ply (III
Chords Tens.Comp. Chords Tens. Comp.
A-B 0 0 E-F 0 -2600
B-C 0-2603 F-G 0 -2600
C- D 0 -2603 G- H 0 -2600
D-E 0-3077 H-1 0 0
Maximum Bot Chord Forces Per Ply (III
Chords Tens.Comp. Chords Tens. Comp
P- O 1570 0 M- L 3077 0
O- N 3077 0 L- K 3077 0
N- M 3077 . 0 K- J 1567 0
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
Q-P
0 -116
L-E
140
-110
A-Q
0 -105
E-K
0
-766
P-B
0-1782
G-K
2
-290
B-O
1173 0
K-H
1172
0
C-O
2 -290
H-J
0
-1779
O-D
0 -762
I-J
0
-105
D-M
138 -110
f
"WARNING" Please alomughly review lhe'A-1 ROOF TRUSSES(°SELLER'), GENERAL TERMS and CONDITIONS CUSTOMER (CUTER) ACKNOWLEDGMENT' form.
eny design parameters and read notes on this Truss Design DmAng (Too) and the Anthony T. Tombo III, P.E. Reference Sheet before use. Unless oNerxise stated on rue Too, only AI{
Truss Design Engineer and Tress Manutaeiurer. unless otherndse donned by a Contract agreed upon In wrNng by all padles Involved. The Truss Design Engineer is f
"Truss System Engineerofeny bunding. All rapitaAzed teems are as defined in TPl-1.
f4mfl R.t RmfTn ttvu!Z.82T.Tn IWRE RnmdzY &Ih� Mom Wm. d vNvMedu dtlh,u remd OAA RmfTna -AnMnv T. TmmM Is, RE
A
AAM N SSE5
Anthony T•Tombo III, P.E.
# 80083
4451 St. Lucie Blvd.
Fort Pierce. FL 34946
Job Truss Truss Type
75775 FL05A SY42
f- 2'6' -I
(TYP)
7'10'8
H
1111.5X4
A
31 =1.5X4(R)
P
Qly Ply
7 I1
04/1112019
10, -} 1T8.1
1111.5X4
=4X6 1111.5X4 ==3X4 =3X4 W=3X4
B C D E F G
11067
=4X6 1111.5X4
H I
�l�
� �Sihiil
SEAT PLATE REQ.
W=H0308
17'8'1
'
Loading Criteria (Pap Wind Criteria
Code / Misc Criteria
De0/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 40.00 Wind Std: NA
Code: FBC 2017 RES
PP Deflecton in too L/defl L#t
Gravity Non -Gravity
TCDL: 10.00 Speed: NA mph
TPI Sid: 2014
VERT(LL): 0.268 M 783 48
Loc R+ / R- / Rh / Rw / U / RL
-
BCLL: 0.00 Enclosure: NA
Rep Factors Used: Yes
VERT(CL):, 0.376 M 558 36C
p 970
BCDL: 5.00 Category: NA
FT/RT:10(0)/10(10)
HORZ(LL): 0.040 B - -
J 962/-
EXP: NAKzt: NA
Des Ld: 55.00 Mean Height: NA ft
Plate Type(s):
WAVE, HS
HORZ(TL): 0.061 B - -
P Brg Width = 7.3 Min Re 1.5
NCBCLL: 10.00 TCDL: NA pat
Creep Factor. 2.0
J B Width =- Min Req
r9 q = -
'
Load Duration: 1.00 BCDL: NA psf
Max TC CSI: 0.728
Bearing P Is a rigid surface.
Spacing: 24.0' MWFRS Parallel Dist: NA
Max BC CSI: 0.881
Bearing P requires a seal plate.
C8C Dist a: NA ft
Max Web CSI: 0.566
Maximum To Chord Forces Per PI Ibs
P Y (Ibs)
Loc. from endwall: NA
Chards Tens.Comp. Chords Tens. Comp.
I: NA GC I: NA
P
Wgt: 95.2lbs
A-B 0 0 E-F 0 -2532
Wind Duration: NA
VIEW Ver. 18.02.01A.0205.20
B - C 0 -2577 F - G 0 -2532
Lumber
C-D 0-2577 G-H 0 -2532
Top chord 4x2 SP#2
D-E 0-3030 H-1 0 0
Bot chord 4x2 SP #2 :B2 4x2 SP M-30:
Webs 4x2 SP #3
Maximum Bat Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
Purlins
In lieu structural panels or rigid ceiling use puriins
P- O 1556 0 M- L 3030 0
al
to laterally brecechords follows:
O - N 3029 0 L - K 3029 0
c)
Chard Spacing(In oc) St0.19 En.67
,
N-M 3029 0 K-J 1484 0
BC 120 0.19 17.67
Apply pudins to any chords above or below fillers
Maximum Web Forces Per Ply (Ibs)
at 24' OC unless shown otherwise above.
Webs Tens.Comp. Webs Tens. Comp.
Hangers/Ties
Q-P 0 -116 L-E 144 -104
(J) Hanger Support Required, by others
A-Q 0 -105 E-K 0 -779
P-B 0-1766 G-K 3 .290
Additional Notes
3-0 1158 0 K- H 1189 0
+ 2x6 continuous stmngback
C - O 0 -291 H - J 0 -1706
Truss must be installed as shown with top chord up.
O-D 0 -742 1-J 0 -98D
- M 133 -114
-WARNING'• Please ihomaghly review the -A-1 ROOF TRUSSES(°SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER') ACKNOWLEDGMENT' fame.
enlydesign Parameters ead need notes on W s Truss Design Dreu%,ng from and theM pony T. Tombo III, P.E. Refe enm Sheet before use. Unless alhervAse stated on the Too only All
annoMr dates shall be used for Me TDD to be valid. As a Truss Design EnglneerNg (i.e. Spedelty Engineer), Me seal on any TDD reonesenM an...ttense of Me DMICad0nal enaineed
rrefenenoedforgenerelguidanee. TPI-1 defines Me responsibilities and Mines
Id agreed upon In wridrg byall parties InwNed. The Truss Design Engineer Is t
kn hftMV 4Nnwnlw,mmti M41Rro Tnauv-Anfh—T Tm IILP.E.
A
AA-/ ROOF
TRUSSF
Anthony T•Tombo III, P.E.
# 80083
4451 St. Lucie Blvd.
Fort Pierce. FL 34946
Job 1 Was I was I ype ury rly uan Ulu tie 11028
75775 FL05B SY42 I 1 1 1 '
�1'4`� Pfl0-j f.. 1T
(TYP) (TYP) (rYP)
2W4 T11"4 T " gT5 101115
�—
=3X3
A B C
971 _1.5X4(
NIL
17'8"1
W=3X4
D E F G H I J K L M N O P
i
II r
I
r
r r
r
r
I
r
r
r
r r
1112X4(R) AE
Loading Criteria (wq
Wind Criteria
TCLL: 40.00
Wind Std: NA
TCDL: 10.00
Speed: NA mph
BCLL: 0.00
Enclosure: NA
BCDL: 5.00
Category: NA
EXP: NAKzt: NA
Des Ld: 55.00
Mean Height: NA ft
NCBCLL: 10.00
TCDL: NA psf
Load Duration: 1.00
BCDL: NA psf
Spacing: 24.0 "
MWFRS Parallel Dist: NA
C&C Dist a: NA ft
Loc. from endwall: NA
I: NA GCpI: NA
Wind Duration: NA
AC AB AA Z Y X W V U I K
W=3X4
SEAT PLATE REQ.
— 17'8"1 —
t
Code I Misc Criteria
Def11CSl Criteria
♦ Maximum Reactions (Ibs), or `=PLF
Code: FBC 2017 RES
PP Deflection in roc
Udefl L/#
Gravity Non -Gravity
TPI Sid: 2014
VERT(LL): 0.001 P
999 480
Loc R+ / R- / Rh I Rw / U / RI!*
Rep Factors Used: Varies by Ld C
VERT(CL): 0.001 P
999 360
Q. 221 P P P I- /-
FT/RT:10(0)/10(10)
HORZ(LL):-0.000 AE
- -
Q Erg Width = 212 Min Req = -
_
Plate Type(s):
HORZ(TL): 0.000 AE
- -
Bearing AF is a rigid surface.
WAVE
Cheep Factor. 2.0
Bearing AF requires a seat plate.
Max TC CSI: 0.301
Maximum Top Chord Forces Per Ply (Ibs)
Max BC CSI: 0.029
Chords Tens.Comp. Chords Tens. Comp.
Max Web CSI: 0.076
A-B 0 0 I-J 0
0
Wgt: 98.0 Ibs
B-C 13 0 J-K 0
0
C-D 0 0 K-L 0
0
VIEW Ver. 18.02.01A.0205.20
D-E 0 0 L-M 0
0
E-F 0 0 M-N 0
0
F-G 0 O N-0 0
0
Top chord 4x2 SP #2
G- H 0 0
O- P
0
0
Bad chord 4x2 SP #2
H-I 0 0
Webs 4x2 SP#3
Bracing
Maximum Bat Chord Forces Per
Ply (Ibs)
Sheathing is required for any longitudinal(dmg) forces. All Connections to be
Chords Tens.Comp.
Chords
Tens. Comp.
designed by the building designer.
AF-AE 0 0
X- W
0
0
Plating Notes
AE-AD 12 0
W- V
0
0
AD -AC 0 0
V- U
0
0
All plates are 1.5X4 except as noted.
AC -AB 0 0
U - T
0
0
AB -AA 0 0
T-S
0
0
Purlins
AA-Z 0 0
S-R
0
0
In lieu of slmctural panels or ngld calling use pudins
Z - Y 0 0
R- Q
0
0
to laterally brace chords as follows:
Y-X 0 0
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0A9 17.67
Apply pudins to any chords above or below fillers
Maximum Web Forces Per Ply (Ibs)
at 24" OC unless shown otherwise above.
Webs Tens.Comp.
Webs
Tens. Comp.
Additional Notes
AG-AF 0 -121
B-AD
0
-37
Provide for Complete drainage of roof.
A -AG 0 -104
P-Q
0
-115
Truss must be installed as shown with top chord up.
I F P PI
lb
Maximum Gab a arms er y ( s)
Gables
Tens.Comp.
Gables Tens. Comp.
AE-B
0 -Z73
I-W
0 -247
AD-C
0 -279
J-V
0 -300
D-AC
0 -294
L-U
0 -288
E-AB
0 -288
M-T
0 -293
F-Z
0 -300
N-S
0 -282
G-Y
0 -247
C-R
0 -328
H-X
0 -147
lh "WARNING" Please amughlyleviewthe'A-1 ROOFTRUSSES('SELLER'), GENERALTERMS and CONDITIONS CUSTOMER
Verify design parameters and lead note on this Thwa Design Drewmg (MD) and the Anthony T. Tomas III, P.E. Reference Sheet before use. U
use
At cadwitred terms are as defined in TPI-1.
la. PE FwMu9MNMUNn'mu't In a,rvlmm. YnrNLW .0 aw.mmXulnnMAtR Tn.-M.T.Tvho III.PE.
e
A I�ROOF
Anthony T•Tombo III, P.E.
# 80083
4451 St. Lucie Blvd.
Fort Pierce, FL 34946
Job I111SS Truss Type pry Ply 04/10/2019
75775 FL06 I SY42 I5 I1 I 10903
H
Loading Criteria (peg
. TCLL: 40.00
TCDL: 10.00
_ BCLL: 0.00
SCOL: 5.00
Des Ld: 55.00
NCBCLL: 10.00
Load Duration: 1.00
Spacing: 24.0"
I- 2'6' ---I
(T1'P)
T5"12-----1 97.4 j 17'4"15
1111.5X4
1111.5X4 =4X6 III1.5X4 =3X4 =3X4 W=3X4 =4X6
A B C D E F G H
1111.5X4
P
O N
M L K
J
=3X6
=-3X8
1111.5X4 III1.5X4 =3X8
=3X6
W=H0308
17'4"15
Wind Criteria
Code! Misc Criteria
Deb/CSI Criteria
♦ Maximum Reactions
(Ibs)
Wind Sid: NA
Code: FBC 2017 RES
PP Deflection in Too Lldefl L/#
Gravity
Non -Gravity
Speed: NA mph
TPI Sid: 2014
VERT(LL): 0.265 L 787 480
Loc R+ / R- / Rh
/ Rw / U ! RL
p 958/-
Enclosure: NA
Rep Factors Used: Yes
VERT(CL): 0.373 L 559 360
Category: NA
FT/RT:10(0)/10(10)
HORZ(LL): 0.038 B - -
J 958!-
EXP: NA Kzl: NA
Plate Type(s):
HORZ(TL): 0.059 B - -
P Big Width =-
Min Req = -
Mean Height: NA it
WAVE, HS
Creep Factor. 2.0
J Big Width =-
9
Min Re q = -
TCDL: NA psf
BCDL: NA psf
Max TC CSI: 0.736
Maximum Top Chord Forces
Per Ply (Ibs)
MWFRS Parallel Dist: NA
Max BC CSI: 0.855
Chords Tens.Comp.
Chords Tens. Comp.
A-B 0 0
E-F 0 -2559
CBC Dist a: NA it
Max Web CST: 0.571
Loc. from endwall: NA
Wgt: 92.4 Ihs
B - C 0 -2498
F - G 0 -2559
I: NA GC I: NA
p
C - D 0 -2498
G- H 0 -2559
VIEW V., 18.02.01A.0205.20
Wind Duration: NA
D-E 0-3004
H-1 0 0
Top chord 4x2 SP #2
Bot chord 4x2 SP #2 :B2 4x2 SP M-30:
Webs 4x2 SP #3
Purlins
In lieu of structural panels or dgid ceiling use pudlns
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(fl)
BC 120 0.00 17.41
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Hangers I Ties
(J) Hanger Support Required, by others
Additional Notes
+2x6 continuous strongback.
Truss must be installed as shown with top chord up.
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
P- O 1442 0 M- L 3004 0
O- N 3003 0 L- K 3004 0
N- M 3003 0 K- J 1546 0
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
A-P
0 -95
L-E
132
-115
P-B
0 -1670
E-K
0
-735
8-0
1198 0
G-K
0
-291
C-O
3 -291
K-H
1150
0
O-D
0 -762
H-J
0
-1755
D-M
144 -102
I-J
0
-105
"WARNING- Please ftneughly revlawthe-A-1 ROOFTRUSSES("SELLER°), GENERAL TERMS and CONDITIONS CUSTOMER("BUYERJAC"OWLEDGMENT"fonn.
stify design Parameters and read notes an Nis Toss Design DraMng (TOO) and the Amhony T. Teraina Ill, P.E. Refemnw Sheet belom use. Unless atherc m slated on the TOD, orlly Alr
amadorplatess llbeusedfor Ne TDDtobevalid. Asa Truss Design Enoimodnad.e.SwdalNEnaineer).Nesealonanv TDDmpreenMana.oranraof M.Rmfe nnAannineed
NmYUTWM ft un wnMn nnmL dMl RnnTn,uu—Mn—vT. Tmm III. PE.
S
AA•1 ROOF
"USS S
Anthony T. Tombo III, P.E.
# 80083
4451 St. Lucie Blvd.
Fort Pierce. FL 34946
Job Truss Truss Type City Ply 04/10/2019'
10942
75775 FL07 SY42 11 1
I-- 2'6° -I
(TYP)
�— 7'10°8 10' 16711 �I
III1.5X4
A
=1.5X4(R)
P
1111.5X4
=4X6 1111.5X4 =3X3 =3X4 W=3X4 =4X6 1111.5X4
B C D E F G H I
is �/ ``I
M
`I
� I�
SEAT PLATE REQ.
Loading Criteria (pap
Wind Criteria
Code / Misc Criteria
TCLL: 40.00
Wind Bid: NA
Code: FSC 2017 RES
TCDL: 10.00
Speed: NA mph
TPI Sid: 2014
BCLL: 0.00
Enclosure: NA
Rep Factors Used: Yes
BCDL: 5.00
Category: NA
FT/RT:10(0Y10(10)
EXP: NAKzt: NA
Plate Type(s):
Des Ld: 55.00
Mean Height: NA ft
WAVE, HS
NCBCLL: 10.00
TCDL: NA psf
Load Duration: 1.00
BCDL: NA psf
Spacing: 24.0'
MWFRS Parallel Dist: NA
C&C Dist a: NA fit
Loc. from endwall: NA
I: NA GCpi: NA
Wind Duration: NA
Lumber
Top chord 4x2 SP #2
But chord 4x2 SP #2 :B2 4x2 SP M-30:
Webs 4x2 SP #3
Purllns
In lieu of structural panels or rigid ceiling use purling
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.19 16.81
Apply pudins to any chords above or below fillers
at 24' OC unless shown otherwise above.
Additional Notes
+2x6 continuous strongback.
Truss must be installed as shown with top chord up.
'•WARNING^ Please thoroughly, reNeu, Me -A-1 ROOF TRUSSES
the Too
1111.5X4
16711
De8/CSI Criteria
PP Deflection in loc L/defl Lt#
VERT(LL): 0:254 M 785 48
VERT(CL): 0.370 D 539 36
HORZ(LL): 0.039 B - -
HORZ(TL): 0.061 B - -
Creep Factor. 2.0
Max TC CSI: 0.821
Max BC CSI: 0.927
Max Web CSI: 0.611
Wgt: 91.0 Ibs
VIEW Ver. 18.02.01A.0205.20
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ I R- / Rh / Rw ! U / RL
P 922 1- /- !- /- /-
J 914 A/-
P Brg Width =7.3 Min Req=1.5
J Brg Width =- Min Req = -
Bearing P is a rigid surface.
Bearing P requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 0 0 E-F 0 -2091
B-C 0-2407 F-G 0 -2091
C-D 0-2407 G-H 0 -2091
D-E 0-7726 H-1 0 0
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
P- O 1468 0 M- L 2726 0
O- N 2727 0 L- K 2723 0
N-M 2727 0 K-J 960 0
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
Q-P
0 -116
L-E
16B
-68
A-Q
0 -105
E-K
0
-863
P-B
0-1667
G-K
10
-288
B- O
1065 0
K- H
1284
0
C-O
0 -298
H-J
0
-1281
O-D
0 -615
I-J
0
-50
D-M
99 -134
GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER') ACKNOWLEDGMENT• form.
an, T. Tamba III,P.E. Reference Sheet before use. Unless or ise slai on the TOO, only Air
. Spedalty Engineer), the seal an any TOD represents an acceptance of Q e professional eagineed
design aesurepuerls, leading conditions, suitability and use of Itlis Truss or any Building is ale
signer, in the mnteW of Ne IRC, the IBC, brat buiWing rude and WP 1. The approval of the
onteMol Ne IRC.Ihe IBC, I.W building coda end TPl-1. The approval of die TDD and anygeld
liliy of 1Ee Building Desgnerand Conimder. All notes selout in deTOD and the produces and
AalerefeencedfargenemlguWance. TPI-idefims NerespansibilidesanddutsdMe Tmss
Anuad agreed upon In w Ung byall parties Involved. The Tmss Design Engineeris NOT the Builk
1.
Wm.dvtluT W dIMwIX,n,n,mi¢[YndFlRMTnN-MMVIVT.T=MIIIP.E.
L ATfl 59E5
Anthony T. Tombo III, P.E.
# 80083
4451 St. Lucie Blvd.
Fort Pierce. FL 34946
Job I Truss Tmss Type City Ply 04/1112019
75775 FL07A I SY42 11 11
11034
3n1 zn1.5X4(I
f-1'4'-I 1-1'4'-1
(TYP) (TYP)
13—�2'7°4i 7'11'4 P, A 15'4°15—}-16'9°--{
=3X3 W=3X4
A B C D• E F G H I J K L M N O
i
ii�l\
dl
—
1
i
I�I�I�ENINININ
i
r
i
r
i li
1
1
i
r
i
r
i
1
1
1
r r
Loading Criteria fps0
Wind Criteria
TCLL: 40.00
Wind Std: NA
TCDL: 10.00
Speed: NA mph
BCLL: 0.00
Enclosure: NA
BCDL: 5.00
Category: NA
EXP: NAKzt: NA
Des Ld: 55.00
Mean Height: NA ft
NCBCLL: 10.00
TCDL: NA psf
Load Duration: 1.00
BCDL: NA psf.
Spacing: 24.0
MWFRS Parallel Dist: NA
C&C Dist a: NA ft
Loc. from endwall: NA
I: NA GCpi: NA
Wind Duration: NA
Lumber
Top chord 4x2 SP #2
Bot chord 4x2 SP #2
Webs 42 SP #3
m y
W=3X4
Code I Misc Criteria
Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(Op10(10)
Plate Type(s):
WAVE
Bracing
Sheathing is required for any longitudinal(drag) forces. All connections to be
designed by the building designer.
Plating Notes
All plates are 1.5X4 except as noted.
Puriins
In lieu of structural panels or rigid ceiling use pudins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.19 16.81
Apply putting to any chords above or below fillers
at 24' OC unless shown otherwise above.
Additional Notes
Truss must be installed as shown with top chord up.
SEAT PLATE REQ.
—16'9"11 —
Defl/CSI Criteria
♦ Maximum Reactions (Ibs), or •=PLF
PP Deflection in roc L/defl
L/#
Gravity Non -Gravity
VERT(LL): 0.000 O
999 480
Loc R+ / R- ! Rh / Rw / U / RL
p• 109 /_ /_ /_ /_
VERT(CL): 0.000 O 999 360
HORZ(LL):-0.000 B
- -
P Brg Width = 201 Min Req = -
HORZ(TL): 0.000 B
- -
Bearing AD is a rigid surface.
Creep Factor. 2.0
Bearing AD requires a seat plate.
Max TC CSI: 0.118
Maximum Top Chord Forces Per Ply (Ibs)
Max BC CSI: 0.029
Chords Tens.Coni Chords Tens. Comp.
A-B 0 0 H-1 0
0
Max Web CSI: 0.034
Wgt: 93.81bs
B-C 6 0 1-1 0
C-D 0 0 J-K 0
D-E 0 0 K-L 0
E-F 0 0 L-M 0
0
0
0
0
VIEW Ver. 18.02.01A.0205.20
F-G 0 0 M-N 0
0
G-H 0 0 N-O 0
0
Maximum Bet Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
AD -AC
0
0
W- V
0
0
AC -AB
5
0
V-.0
0-
0
AB -AA
0
0
U-T
0
0
AA-Z
0
0
T-S
0
0
Z-Y
0
0
S-R
0
0
Y-X
0
0
R-Q
0
0
X-W
0
0
Q-P
0
0
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
AE-AD 0 -59 B-AB 0 -17
A-AE 0 -48 O-P 0 .41
Maximum Gable Forces Per Ply (Ibs)
Gables Tens.Comp. Gables Tens. Comp
AC-B
0 -126
H-V
0
-103
AS-C
0 -128
1-U
0
-138
D-AA
0 -135
J-T
0
-in
E-Z
0 -132
L-S
0
-134
F-X
0.-138
M-R
0
-130
G-W
0 -103
N-Q
0
-149
"WARNING" Please thoroughly review Me-A-1ROOF TRUSSES ("SELLER°), GENERALTERMS and COMMONS CUSTOMER('BUYER') ACKNOWLEDGMENT' room.
unity design parameters and read ad. on Ws Tmss Design Dral MD) and the Anthony T. Tombo III, P.E. Reference Sheet before use. Unless ofaerWse slated an Me TDD, only All
mnedor dates shall be used fortbe TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), Me seal on arty TOD represents an acceptance of the professional englneed
Isposelblityforthe design of Me single Truss depicted on Me TDD only, under TPI-t.The design assumptions, loading conditions, sumbllhy and use of this Truss forany Building Is Me
Wilding is the responsibility ofthe Owner, the Owners authorized agent orthe Building Designer. In the conte,dof be IRO. Me IBC. beat buildina sodeand TPl-1. The aoomval of the
rug nanaung, storage, Installatmn and blades shall be Me responsibllily of the Building Designer and Contractor. All notes set oat in Ne TDD and the pro
lof the Building Component Safety lnformstion(BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the respousLilims and does
Truss Design EnglneeraMTeuss Manufadumt unlessotheoulse dented bye Contrsdegreed upon Invading byall parms Involved. TheTmss Design Englneerlst
v TrussSystem Enginearof a ybullding. A➢ ppitaraed terms areas dewed In TPI-1.
l2nmMtRMTnw•wv_Mt T.Tnr,nh. Ps Fxr '—nfur Er,nmwp Fvmlmm.lx ruMIM111M vi1M01Mw,illnn mnnlcW,NilflMTnvux_MMmrT. TrvnM III. PE.
3
',,�a
'I-A-1 RDOF
ar TTRRUSSES
Anthony T•Tombo III, P.E.
# 80083
4451 St. Lucie Blvd.
Fort Pierce, FL 34946
Job
75775
I fuss
FL07G
I fuss Iype
SY42
wry, I Fly
D41il/Lino
10939
R
�— 7'11.4
�— 2'6'
(TyP)
7'10'8
011.5X4
A
3e1 al ml.5X4(R
=4X8
B
300#
011.5X4 =3X6
C D
8'10'7
10,--1 16'9'11 —j
1111.5X4
=3X4 W=3X4 =4X8 101.5X4
E F G H I
11% \I%
1
ter%
CS
011.5X4
SEAT PLATE REQ.
16711
Loading Criteria (par)
Wind Criteria
Code I Misc Criteria
De81CS1 Criteria
TCLL: 40.00
Wind Std: NA
Code: FBC 2017 RES
PP Deflection in loc Udefl L/#
TCDL: 10.00
Speed: NA mph
TPI Std: 2014
VERT(LL): 0.319 M 624 48�
BCLL: 0.00
Enclosure: NA
Rep Factors Used: No
VERT(CL): 0.439 M 454 36i
BCDL: 5.00
Category: NA
FT/RT:10(Oy10(10)
HORZ(LL): 0.045 J - -
EXP: NA Kzt: NA
Plate Type(s):
HORZ(TL): 0.062 J - -
Des Ld: 55.00
Mean Height: NA ft
WAVE, HS
Creep . 2
NCBCLL: 10.00
TCDL: NA psf
Max TC CSI:SI: 0602
Load Duration: 1.00
BCDL: NA psf
.
Spacing: 24.0"
MWFRS Parallel Dist: NA
Max BC CSI: 0.873
C&C Dist a: NA it
Max Web CSI: 0.871
Loc. from endwall: NA
Wgt: 95.2Ids
I: NA GCpi: NA
VIEW Ver. 18.02.01 A.0205.20
Wind Duration: NA
Lumber
Top chord 4x2 SP M-30 :T2 4x2 SP #2:
Bot chord 4x2 SP M-30
Webs 4x2 SP #3
'
Special Loads
—(Lumber Dur.Fac. 1.00 / Plate Dur.Fac.=1.00)
TC: From 100 plf at 0.12 to 100 plf at 6.44
TC: From 284 plf at 6.44 to 284 plf at 9.44
TC: From 100 plf at 9.44 to 100 plf at 16.81
BC: From 10 pif at 0.00 to 10 pif at 16.81
Purlins
In lieu of structural panels or rigid ceiling use putting
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.19 16.81
Apply puffins to any chords above or below fillers
at 24' OC unless shown otherwise above.
Loading
Truss checked for 300# movable concentrated load along Top Chord, between
7-11-4 to 7.11-4, nonconcurrent with design gravity loads.
Additional Notes
+2x6 continuous sbongbacic
Provide for Complete drainage of roof.
Truss must be installed as shown with top chord up.
4
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- IRh /RW /U /RL'
P 1217 /- /- !- /- /- -
J 1171 A l-!-
P Brg Width =7.3 Min Req=1.5
J Brg Width =- Min Req = -
Bearing P is a rigid surface.
Bearing P requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B .0 0 E-F 0 -2866
B-C 0-3512 F-G 0 -28%
C-D 0.3512 G-H 0 -2866
D-E 0-3962 H-1 0 0
Maximum got Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
P- O 2010 0 M- L 4329 0
O- N 4329 0 L- K 3937 0
N- M 4329 0 K- J 1254 0
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
Q-P
0 -118
D-L
0 -441
A-Q
0 -107
L-E
273 0
P-B
0-2282
E-K
0 -1216
S-O
1704 0
G-K
0 -248
C- O
0 -324
K- H
1829 0
O-D
0 -922
H-J
0 -1673
D-M
31 0
1-1
0 -45
"WARNING" Please thoroughly review Be 'A-1 ROOF TRUSSES('SELLER'), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER') ACKNOWLEDGMENT farm.
Verify design parameters and read notes on this Truss Design Drawing COD) and the Amhony T. Tambo III, P.E. Reference Sheet before use. Unless onanxiss stated an the Too, only All
connector plates shall be used for ale MD to be varid. Asa Tmss Design Engineering p.e. Spadelty Engineer), the seal on any TDD mpresenb an a=pgnw of the pmfessional engineen
responibillty forthe design of the single Truss depicted on Ne TDD only, under TPI-1. The design assumption, loading candaiore, suitability and use of Nis Truss (wary Building ism
Buildnr is the reemnsihilihv fthe �ec the Ownela a,Medxed anent or the Ruileina OPeformn in the mnlext of fire IRC. the IBC. real buldina code and TP1-1. Theaoploval of lha
Illation and among shall be the responsibility ofthe Building Designer and Cartrdetw. AenotessetoutinammDandlhepraclicesand
nation(ESCI)published by TPI and SBC.Aare referenced fwgeneralgudalsm. TPI-1 defines the responsibilidesend dales ofthe Tlut
Aacturep unless otherwise dented by a Contract agreed upon in wum ng by all parties involved. The Truss Design Engineeris NOT Ne Bt
Ail cepitaored terms are as defined In TPl-1.
In PE Rm UmffidagMM munlTruM111. PE.
e
4�A4 ROOF
1TRU55E5
Anthony T•Tombo III, P.E.
# 80083
4451 St. Lucie Blvd.
Fort Pierce, FL 34946
Job Truss Truss Type
75775 FL08 SY42
f ^ 2'6- ---{
(TYP)
r 77
1111.5X4 =4X6 1111.5X4
A B C
Loading Criteria (purl
TCLL: 40.00
TCDL: 10.00
BCLL: 0.00
BCDL: 5.00
Des Ld: 55.00
NCBCLL: 10.00
Load Duration: 1.00
Spacing: 24.0 °
Qty y 104/10/2019
3 I i
9-10.8 ---1 16'107
III1.5X4
=3X3 =3X4 W=3X4 =4X6 1111.5X4
D E F G H I,
P O N M L K J
=3X6 =-3X8 W=HO308 1111.5X4 =-3X10 =3X4
1111.5X4
Wind Criteria
Wind Std: NA
Speed: NA mph
Enclosure: NA
Category: NA
EXP: NA Kzt: NA
Mean Height: NA it
TCDL: NA psf
BCDL: NA psf
MWFRS Parallel Dist: NA
C&C Dist a: NA it
Loc. from endwall: NA
1: NA GCpi: NA
Wind Duration: NA
Lumber
Top chord 4x2 SP #2
Bot chord 4x2 SP #2 :B2 4x2 SP M-30:
Webs 4x2 SP #3
Purley,
In lieu of structural panels or rigid ceiling use pudins
to laterally brace chords as follows:
Chord Spacing(In oc) Start(ft) End(ft)
BC 120 0.00 16.87
Apply pudins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Hangers I Ties
(J) Hanger Support Required, by others
Additional Notes
+2x6 continuous slrongback.
Truss must be installed as shown with top chord up.
16'10°7
10969
Code I Misc Criteria
DegICSI Criteria
• Maximum Reactions (Ibs)
Code: FBC 2017 RES
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TPI Sid: 2014
VERT(LL): 0.262 M 771 480Loc
R+ / R- / Rh / Rw / U / RL
p 928 /- /- /- /- /-
Rep Factors Used: Yes
VERT(CL): 0.379 D 534 360
FT/RT:10(0yl0(10).
HORZ(LL): 0.040 B - -
J 928 /- /- /- /- /-
PlateType(s):
HORZ(TL): 0.062 B - -
P Big Width= - Min Req=-
WAVE, HS
Creep Factor. 2.0
J Erg Width =- Min Req = -
Max TC CSI: 0.817
Maximum Top Chord Forces Per Ply (Ibs)
Max BC CSI: 0.999
Chords Tens.Comp. Chords Tens. Comp.
A-B 0 0 E-F 0 -2197
Max Web CSI: 0.606
Wgt: 89.61bs
B-C 0-2473 F-G 0 -2197
C-D 0-2473 G-H 0 -2197
VIEWVer.18.02.01A.0205.20
D-E 0-2812 H-1 0 0
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
P-O 1524 0 M-L 2812 0
O-N 2813 0 L-K 2BO9 0
N-M 2813 0 K-J 1077 0
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
A-P
0 -108
L-E
165
44
P-B
0-1721
E-K
0
-855
B-O
1077 0
G-K
9
-2B9
C-0
0 -296
K-H
1272
0
O-D
0 -637
H-J
0
-1371
D-M
104 -132
I-J
0
-62
"WARNING" Please thoroughly review the-A-1ROOF TRUSSES("SELLER-), GENERAL TERMS and CONDITIONS CUSTOMER (BUYER-) ACKNOWLEDGMENT- farm.
arty design Parameters and read notes on this Truss Design Drawing (TDD) end the Anthony T. Tombo III, P.E. Reference Sheet beforeuse. Unless other stated on the TDD, onlyAll
mnedor dates shag be used forthe TDD to bo valW. As a Tmw Design Engineadnp g.e. Sp delty Emw eer). Na seal m anv TDO represents an a=Dtanm cf Ma nmfeseinnA eneineed
In
Willa nwwlRm M,M all NM1 aMTn,ww-Mavnv T. TtMn III. P E.
9
A-1 ROOF
TRUSSES;
Anthony T. Tombo III, P.E.
# 80083
4451 St. Lucie Blvd.
Fort Pierce, FL 34946
Job Truss Truss Type Cry Ply 04/11/2019 10951
75775 1 FL09 I SY42 1 1
�-- 1-11"12 --1— 4'1 n4 1 6-4-12 — - {
1111RX4 =IX3 11118X4
1.5X4(R;
■
�ill F
n 1 e■
imI I..:■
■1 u�llll
=3X6
1112X4(R)
SEAT PLATE REC.
6'4°12
Loading Criteria (asp
Wind Criteria
Code I Mlsc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 40.00
Wind Std: NA
Code:FBC 2017 RES
PP Deflection in loc L/defl L/#
Gravity Non -Gravity -
TCDL: 10.00
Speed: NA mph
TPI Sid: 2014
VERT(LL): 0.027 C 999 480
Loc R+ I R- / Rh / Rw / U / RL
1 339 /- /-- /- /- h
BCLL: 0.00
Enclosure: NA
Rep Factors Used: Yes
VERT(CL): 0.042 C 999 360
BCDL: 5.00
Category: NA
FT/RT:10(0Y10(10)
HORZ(LL):-0.011 D - -
F 339 /- /--
EXP: NA Kzt: NA
Plate Type(s):
HORZ(rL): 0.017 D - -
I Brg Width = 7.3 Min Req = 1.5
Des Ld: 55.00
Mean Height: NA ft
WAVE
Creep Factor. 2.0
F Brg Width = 3.5 Min Req = 1.5
NCBCLL: 10.00
TCDL: NA psi
Max TC CSI: 0.290
Bearings I & F are a rigid surface. _
Load Duration: 1.00
BCDL: NA psi
Max BC CSI: 0.260
Bearing I requires a seal plate.
Spacing: 24.0"
MWFRS Parallel Dist: NA
Max Web CSI: 0.193
MaxTens.Comp.
Maximum Top Chord Forces Per Ply (Ibs)
G Dist a: NA it
Chords Tens. Comp.
Lo
Lo c. from l: NA
Wgt: 44.81bs
I: NA GCpj: i: NA
A-B 0 0 C-0 0 -332
VIEW Ver. 18.02.01A.0205.20
Wind Duration: NA
B - C 0 -342
Lumber
Top chord 4x2 SP #2
Maximum Bat Chord Forces Per Ply (Ibs)
Bot chord 4x2 SP #2
Chords Tens.Comp.
Chords Tens. Comp.
Webs 4x2 SP#3
I-H 341 0
G-F 0 0
Purlins
H-G 342 0
In lieu of structural panels or rigid ceiling use pudins
Maximum Web Forces Per Ply (Ibs)
to laterally brace chords as follows:
Chord Spacing(in oc) Stari(ft) End(ft)
Webs Tens.Comp.
Webs Tens. Comp.
BC 72 0.19 6.21
Apply pur ins to any chords above or below fillers
J - I 8 -
G - D 405 0
at 24" OC unless shown otherwise above.
A - J 9 -75
D - E 0 -317
s
I-S 0 -430
F-E 0 -6
Additional Notes
'B -H 70 0
E-F 0 -322
Truss must be installed as shown with top chard up.
C - G 0 -223
"WARNING" Please Nomughly mNm the -A-1
audlodzed
h
TERMS and
use
rue
Lv NM TXM viaua0 RwwiXmnamixW�NA.t RWTnu -MO vT.Tm 3.PE
�QA-I RGGF
DTRn55E5
Anthony T•Tombo III, P.E.
# 80083
4451 St. Lucie Blvd.
Fort Pierce. FL 34946
Job
75775
Truss
FL10
Truss Type
SY42
Cry 4 I Ply
10411112019
10948
Loading Criteria has
TCLL: 40.00
TCDL: 10.00.
BCLL: 0.00
BCDL: 5.00
Des Ld: 55.00
NCBCLL: 10.00
Load Duration: 1.00
Spacing: 24.0"
Top chord 4x2 SP 42
Sot chord 4x2 SP #2
Webs 4x2 SP #3
(TYP)
�-- 2-0"8 —1 4'2° -{ 6'5"8 --�
1111A5X4 EEjX3 1111�X4 =3b3
Wind Criteria
Wind Std: NA
Speed: NA mph
Enclosure: NA
Category. NA
EXP: NAKzt: NA
Mean Height: NA it
TCDL: NA psf
BCDL: NA psf
MWFRS Parallel Dist: NA
C&C Dist a: NA ft
Loc. from endwall: NA
I: NA GCpi: NA
Wind Duration: NA
Mill
'lip
,J4
Purlins
In lieu of structural panels or rigid ceiling use purling
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) Erl
BC 75 0.00 6.27
Apply pudins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Additional Notes
Truss must be installed as shown with top chord up.
"WARNING" Please thoroughly review the -A-1
on the TDD
1.5X4(R) 3"1
1112X4(R)
6'5"8
Code I Misc Criteria
DeflICSI Criteria
♦ Maximum Reactions (Ibs)
Code:FBC 2017 RES
PP Deflection In Ioc L/defl L#f Gravity Non -Gravity
TPI Std: 2014
VERT(LL): 0.025 C
999 480 LOG R+ / R- / Rh / Rw / U / RL
Rep Factors Used: Yes
VERT(CL): 0.039 C
999 360 1 345
FTIRT:10(Ou10(10)
HORZ(LL): 0.011 B
- - F 353/-
Plate Type(s):
WAVE
HORZ(TL): 0.017 B
- - I Brg Width =- Min Req = -
Creep Factor. 2.0
F Brg Width = 3.5 Min Req = 1.5
Max TC CSI: 0.278
Bearing F is a rigid surface.
Max BC CSI: 0.242
Maximum Top Chord Forces Per Ply (Ibs)
Max Web CSI: 0.211
Chords Tens.Comp. Chords Tens. Comp.
Wgt:42.01bs
A-B 0 0 C-D 0 -364
B - C 0 -375
VIEW Ver. 18.02.01A.0205.20
Maximum Sot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
I-H 374 0 G-F 0 0
H - G 375 0
Maximum Web Forces Per Ply (Ibs)
Webs _ Tens.Comp. Webs Tens. Comp
A-1 0 -90 G-D 444 0
I-B 0 -451 D-E 0 -335
B-H 69 -9 F-E 0 -6
C-G 0 -232 E-F 0 -341
1 !- TERMS and CONDITIONS CUSTOMER('BUYER°) ACKNOWLEDGMENT- form.
Tombo ill, P.E. Reference Sheet before use. Unless otherwise slated on the MO. only Alp
rrefereacedsorgenemlguidance. TPI-1 defrnestheresponsibilides and duties
uA agreed upon In "Uh, byalt padles involved. The Truss Design Engineeris I
MNMs,Med dq" ff-Mln!1 MdA.1RMTnww.e-Ma vT Tm 111. GE.
d
"11�A-f RRDF
mTRU55E5
Anthony T. Tombo III, P.E.
# 80083
4451 St. Lucie Blvd.
Fort Pierce. FL 34946
Job Truss
75775 FL11
Truss Type
SY42
Cry Ply
10411012019
10918
�-- 1'8"11 --�
(TYP)
1 3715 —�
1111A.5X4 =3BX3 1111.5X4
1.5X4( D
3"1
F E
=3X3
=3X6
3715
r
Loading Criteria (psp Wind Criteria
Code I Misc Criteria
DeIIICSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 40.00 Wind Sid: NA
Code: FBC 2017 RES
PP Deflection in loc L/defl L/# Gravity Non -Gravity
TCDL: 10.00 Speed: NA mph
TPI Sid: 2014
VERT(LL): 0.004 B
999 480 Lee R+ I R- / Rh / Rw / U I RL
BCLL: 0.00 Enclosure: NA
Rep Factors Used: Yes
VERT(CL): 0.005 B
999 360 F 200 /- /- /- ' /-
BCDL: 5.00 Category: NA
FT/RT:10(0y10(10)
HORZ(LL): 0.001 E
- - E 208 /- /- A l- I-
EXP: NA Kzt: NA
Plate Type(s):
HORZ(TL): 0.001 E
- - F Brg Width = - Min Req = -
Des Ld: 55.00 Mean Height: NA it
WAVE
Creep Factor. 20.
E Big Width = 3.5 Min Re 1.5
9 q =
NCBCLL: 10.00 TCDL: NA psf
Max TC CSI: 0.267
Bearing E Is a rigid surface. -
Load Duration: 1.00 BCDL: NA psf
Max BC CSI: 0.267
Maximum Top Chord Forces Per Ply (Ibs)
Spacing: 24.0 ° MWFRS Parallel Dist: NA
Max Web CSI: 0.047
Chords Tens.Comp. Chords Tens. Comp.
C&C Dist a: NAft
Loc. from endwall: NA
Wgt: 28.0lbs
A-B 0 0 B-C 0 0
I: NA GCpi: NA
Wind Duration: NA
VIEW Ver. 18.02.01A.0205.20 Maximum Sot Chord Forces Per Ply (Ibs)
Lumber
Chords Tens.Comp.
Top chord 4x2 SP#2
F-E 147 0
Bot chord 4x2 SP #2
Webs 4x2 SP #3
Maximum Web Farces Per Ply (Ibs)
Pudins
Webs Tens.Comp. Webs Tens. Comp.
In lieu of structural panels or rigid ceiling use pudins
A- F 0 -73 C - D 0 -69
to laterally brace chords as follows:
F - B 0 -184 E - D 0 -6
Chord Spacing(in oc) Start(ft) End(ft)
B-E 0 -186 D-E 0 -74
BC 44 0.00 3.64
Apply pudins to any chords above or below fillers
at 24' OC unless shown otherwise above.
Additional Notes
Truss must be installed as shown with top chord up.
"WARNING" Pleaseffenighlyrevieethe-A-1 ROOF TRUSSES("SELLER-), GENERALTERMS and CONDITIONS CUSTOMER(-BUYEW)ACMOWLEDGMENT-folm.
'a* design parameters end reed notes an this Truss Design DreU.ing CMD) and the Anthony T. Tomho 111. P.E.Refersom Sheet before Use. Unless otherwise stated on the Too, only All
TPI-1.
µry eeV dfj, ntt mmniWm of M1 Rmf TnM T. TmiM III, PE.
L�A-1 ROOF
/"�.d' TRU65E5
Anthony T.Tombo III, P.E.
# 80083
4451 St. Lucie Blvd.
Fort Pierce. FL 34946
Job
75775
Truss Truss Type
A01 IGABL
City
I Ply
104/10/2019
10741
Loading Criteria (pen
TCLL:
30.00
TCDL:
10.00
_ BCLL:
0.00
BCDL:
10.00
Des Ld: 50.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
1e94
Wind Criteria
Code I Misc Criteria
Wintl Std: ASCE 7-10
Code: FBC 2017 RES
Speed: 160 mph
TPI Sid: 2014
Enclosure: Closed
Rep Factors Used: No
Risk Category: II
FT/RT:10(Ov10(10)
EXP: C Kzb NA
Plate Type(s):
Mean Height: 21.74 It
WAVE
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.50 it
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP 24001-2.0E :T2 2x4 SP M-30:
Bot chord 2x4 SP 24001-2.0E
Webs 2x4 SP #3
Special Loads
--(Lumber Duffac =1.25 / Plate DunFac=1.25)
TC: From 234 pit at 0.00 to 234 pit at 33.54
BC: From 100 plf at -0.44 to 100 pit at 0.00
BC: From 20 plf at 0.00 to 20 pit at 2.10
BC: From 24 plf at 2.10 to 24 pit at 9.20
BC: From 20 pit at 9.20 to 20 pit at 24.34
BC: From 24 plf at 24.34 to 24 pit at 31.44
BC: From 20 plf at 31.44 to 20 pit at 33.54
BC: From 100 pit at 33.54 to 100 pit at 33.98
Plating Notes
All plates are 1.5X4 except as noted.
Purling
1a9Y
DeflfCSI Criteria
PP Deflection in roc Udell L/#
VERT(LL): 0.196 R 434 361
VERT(CL): 0.334 R 254 241
HORZ(LL):-0.128 X - -
HORZ(TL): 0.219 X - -
Creep Factor- 2.0
Max TC CSI: 0.739
Max BC CSI: 0.597
Max Web CSI: 0.449
Wgt: 191.8lbs
VIEW Ver. 18.02.01 A.0205.20
The maximum horizontal reaction is 494#
See STD DETAILS for gable wind bracing requirements.
axe(pn
♦ Maximum Reactions (Ibs), or •=PLF
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw l U I RL
A' 377 1- /-
/369 /157
1194
AL* 143 /- !-
/130 /59
/-
AH•346 /- !-
/283 /146
/-
AM•209 /- !-
/194 185
/-
AM`1 /-27 /-
/42 137
1-
AA /-241
Wind reactions based on MWFRS
A Brg Width =30.5
Min Req =-
AL Brg Width = 85.1
Min Req = -
AH Brg Width =181
Min Req = -
AM Brg Width = 85.1
Min Req = -
AM Brg Width = 30.5
Min Req = -
Bearings A, AL, AH, Y, & AM are
a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
A-B
304 -494
K-L
457
-179
B-C
270 -458
L-M
345
-122
C-D
373 -353
M-N
225
-fib
D-E
348 -339
N-O
139
-122
E-F
463 -223
O-P
142
-319
F - G
247 -279
P - Q
392
-146
G-H
212 -265
Q-R
227
-118
H-1
304 -170
R-S
140
-300
1-1
345 -226
S-T
190
-419
J-K
457 -209
T-U
115
-255
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
In lieu of structural panels or rigid ceiling use pur ins
A -AL
386 -230
AD -AC
453
-205
to laterally brace chords as follows:
AL -AK
333 -282
AC -AB
450
-198
Chord Spadng(in cc) Start(ft) End(ft)
AK-AJ
402 -275
AB -AA
449
-192
BC 31 0.00 2.54
BC 75 2.64
AJ-AI
931 -654
AA-Z
284
-68
4.64
78
BC 175
AI-AH
330 -278
Z-Y
294
-95
BC 75 4.78 31.88
34.42
AH-AG
282 -214
Y-X
254
-75
31.88
BC 31 31.88 34.42
AG-AF
449 -198
X - W
232
-118
Apply putting to any chords above or below fillers
AF-AE
450 -200
W - V
253
-190
at 24" CC unless shown otherwise above.
AE-AD
453 -205
V - U
260
-121
Wind
Maximum
Web Forces Per Ply (Ibs)
Wind loads based on MWFRS with additional C&C member design.
Webs
Tens.Comp.
Webs
Tens. Comp.
B -AL
246 -532
AA- P
391
.339
F-AG
332 -fib
V-T
434
-984
"WARNING" Please thoroughly revlew to-A-1ROOF TRUSSES('SELLER°), GENERAL TERMS and CONDITIONS CUSTOMER(°BUYER-) ACKNOWLEOGMENr torn.
e
adfy design parameters and read notes on this Truss Design Drs'Mg (MD) and No Anthony T. TomEo III, P.E. Reference Sheet before use. Unless 011, a stated on the MD, only Ali
3nnedwplatesshallbeusedfwMeTODtobevalid. As a Truss Design Engineering (i.e.Spedaiy Engineer), Me seal on any TDD represents an acceplanoo ofihe professional engineelin
mponsollity for the design ofthe single Truss depicted on the TDD only, under TPl-1. The design assumptions, loading conditions, suitability and use ofihis Truss forany Building is the
A RRDF
�TRr155E5
uilding is Me responsibility of the Owner, the Owners authorized agent or the Building Designer. In the context of the IRC, the IBC, local building rude and TPI-1. Theeppreval of the
IspOnsibility, of the owner, the Owners auWrtmd agent or the Building Designer, in Me wriest of the IRC, the IBC. local building code and TPI-1. The approval of the TDD and any Geld
se ofthe Truss, looming handling. storage. Installation and bracing shelf be the responsibirny ofthe Building Designer and Contractor. Minoessetoutmmem0andumprawcesand
Anthony TombO ill, P.E.
nY
uidellnes ofthe Building Component Safety lnformadon(BSCI)Published by TPI and SBCA are referenced for general guidance. TPI-ldefiwsthemsponsibilillesmdduti of Na Luse
#80083
tudgnar, Truss Design Engineer and Trues ManNacNrer, unless otherwise dented bye Contract agreed upon In vMing by all paNes involved. The Tmss Design Eegineerts NOTthe Buildi
4451 St. Lucie Blvd.
esigner 0r Truss System Eng4- of any I . All apilaAzed temaare asdented NTPI-1.
noMnM44a1fl0.1RMTn,w�rmv T,TpNTnnuN III, PE. nwrtNu]4nn(MIctlMVMnL4nmlmm.4rmlNiiIMWIMnIMwnnan narrnlxxllniNMl emlTn4uv._pnuvnr T. T"nminP.e
Fort Pierce, FL 34946
Truss Truss Type Oty Ply 04/10/2019 10741
A01 I GABL 2 1 1
Maximum Gable Farces Per Ply (lbs)
Gables
Tens.Comp.
Gables
Tens.
Comp.
C -AK
. 90 .140
AC- L
265
-524
D -AJ
306 -642
AB- M
243
-486
E -AI
158 -281
O -AA
93
0
AH-F
283 -582
P-Z
444
-970
AG-G
162 -310
Y-Q
154
-273
1-AF
235 -466
X-R
111
-168
J-AE
266 -526
W-S
91
-141
K -AD
207 .569
"WARNING" Please Nomughly review the'A-1 ROOF TRUSSES(°SELLER'), GENERAL TERMS and CONDITIONS CUSTOMER MUYER') ACMOWLEOGMENP toms.
Verify design parameters and need notes on We Twos Design Drewing (TOO) and to Anthony T. Tonnbo 111, P.E. Referenoa Sheet beforeuse. Unless oteraise staled on rue TDD, only Alp
The
os Manufacturer, unless oMendse darned by a Conrad agreed upon In willing by all pelves Involved. The Twos Design Engineer Is I
tabling. All capitaltrrms sl teare as dabbed In TPI-1.
I. T.IIL PE. RlvvMivLm Nqu Nvamxtl. Nano NvMiFitM u+llwn Tnvrltm re+mLcsim MMt Rmf Tnnsm-MMnv T.T(min1II.PE.
I.
,A-1 RODF
9TWUSSE5
Anthony T. Tombo III, P.E.
# 80083
4451 St. Lucie Blvd.
Fort Pierce. FL 34946
Job
75775
Truss Truss Type
A02 I COMN
City Ply 04/10/2019
17 1
10757
Loading Criteria (pan
TCLL: 30.00
TCDL: 10.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 50.00
NCBCLL: 10.00
- Load Duration: 1.25
Spacing: 24.0 "
Tj In-10 -I 1] 10�
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 21.91 ft
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.50 fit
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x6 SP 2400f-2.0E
Sot chord 2x6 SP 2400f-2.0E :B1 2x4 SP
2400f-2.0E:
Webs 2x4 SP #3:W2 2x4 SP #2:
:W4, W5 2x6 SP 2400f-2.OE:
Code I Misc Criteria
Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(OU70(10)
Plate Type(s):
WAVE, HS
Bracing
(a) Continuous lateral restraint equally spaced on member.
t'r6%film
De01CS1 Criteria
PP Deflection in lac Udell L#f
VERT(LL): 0.623 H 668 36(
VERT(CL): 1.081 H 385 24(
HORZ(LL): 0.663 N - -
HORZ(TL): 1.151 N - -
Creep Factor. 2.0
Max TC CSI: 0.381
Max BC CSI: 0.976
Max Web CSI: 0.934
Wgt 256.2 Ibs
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- I Rh l Rw I U / RL
A 1885 /- /- /933 /694 /510
M 1885 /- I- 1930 1696 /-
Wind reactions based on MWFRS
A Brg Width = 6.0 Min Req = 1.6
M Brg Width = 6.0 Min Req = 1.6
Bearings A & M are a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A - B 1715 -3726
G - H
2O25 -4380
VIEW Ver. 16.02.01 A.0205.20 B - C 3379 -8042
H - I
1834 -4323
Additional Notes C-D 3907-9856
1-1
1820 -4403
D - E 18 -4402
J - K
3907 -9858
WARNING: Furnish a copy of this DWG to the installation contrigeto Spe rP�
bee
K- L
3379 -8043
must be taken during handling, shipping and installation of buSS0-'_
"WARNING" note below. ' 2025 4379
L- M
1715 -3727
Maximum Bot Chord Forces Per
Ply (Ibs)
Chords Tens.Comp.
Chords
Tens. Comp.
Plating Notes
All plates are 6X8 except as noted.
(") 2 plate(s) require special positioning. Refer to scaled plate plot details for
special positioning requirements.
Purling
A - U
3169 -1414
Q - P
73Z -2525
U - T
3626 -1614
P - O
7883 -3055
T-S
7882-3OW
O-N
3627 -1614
S-R
7325-2525
N-M
3169 -1414
R-Q
2513 -449
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
In lieu of structural panels or rigid ceiling use pudins
B - U
831 -1690
G - Q
2452 -1108
4o laterally brace chords as follows:
B-T
3716-1278
Q-H
318 -291
Chord Spacing(in oc) Start(ft) End(ft)
T-C
466-1103
Q-J
1725 -4071
BC 34 0.00 2.83
BC 79
C - S
1596 -276
J - P
4524 .1697
BC 88 9.93 5.93
07
S - D
4523 -1697
P - K
1597 -276
BC 79 5.07 32.17
35.00
D - R
1725 -4071
K - O
466 -1103 '
32.17
BC 34 32.17 35.00
F-R
318 -291
O-L
3717 -1278
Apply pudins to any chords above or below fillers
R - G
2450 -1108
N - L
831 -1690
at 24" OC unless shown otherwise above.
Loading
Truss passed check for 20 psf additional bottom chord live load in areas with
42"-high x 24'-wide clearance.
Wind
Wind loads based on MWFRS with additional C&C member design.
"WARNING" Please thoroughly revimffie'XI ROOF TRUSSES("SELLER), GENERALTERMS and CONDITIONS CUSTOMER ('BUYER) ACWOWLEDGMEN form.
.r
'edfy design parameters and read notes an this Truss Design Draving(TDD) and theAnthany T. Tombo ill, P.E. Reference Sheet before use. Unless oNerWa, stated on Ne T00, only Alpi
arrestor plates shall be used for Me Too to be wild As a Truss Design Ergmeetlngna. Specialty Engineer), the seal on any Too represents an acceptance of Me pmfesabhat engineer.
L Act RODF
sporeflaity for the dtsignafibe single Truss depicted an the Too only, under TPI-I. The design assumptions, loading conditions, sullabildy and use arable Tress for.,Bulidingis Ne
/ TRr155E5
Old, is the responsibility ofthe Owner Me Owners auNodred agent orthe Building Designer, In Me cented of the IRC, the IBC. local building code and TPI-I. Theapprowl of Ne
asPonslbgit ibe Ownegthe OwnersauNorbed agentorthe Building Designer, In the center ofNe IRC, Me IBC, local building code and TPl4. TheapprovaloftheTDDandenygeld
Truss, including
Anthon LTombo ill, P.E.
y
se oflhe handling. storage, installation and bma ng shall be the responslbifrty, ctor ofthe Building Designerand Contre. Minotessetoulln Me TDDand Neprac icesentl
uldelines ofthe Building Component Safety Information(BSCI) published by TPI and SECA are referenced for general Vdance. TPI-1 defines Me respanslbiiitiesand dullesofthe Truss
#80083
ladgner, Truss Design Englnew aW Truss Manufacturer, unless oNervdse dermed bya Con agmed upon In wlidng byag pedies lnwlved. The Truss Design Engireer is NO"I Me Build
4451 St. Lucie Blvd.
esigneror Truss System Engineer of any building. AA mpilalood terms ere as definedIn TPI-1.
mMM101016A-IRm Tn,--Ann T.Tr ,11.PE. rt mxIMNMlaono eM1hmhW ihmrhhue Wnwd lMwwmrmiae4nn1M1 Rmf Tnuwa-MAmv T.Try III PE.
Fort Plerce. FL 34946
Job Truss Truss Type
75775 A02A COMN
?Y 173.1a
r I l 104110/2019
Dt5,6R)
m1.6YAF HIIt.sx4
I
12 /6"D J %6xa
S a al (a)
0"C K%3x6
- T IS R D P
oH0710(SRS) .5x10 -5x10 %H0710(SR3)
B T C L
s(O1)q Q 0 Mai%6(D1)
1 12
at u ,N6 e1
0Sx6
I-Zers 0 rl•2- I
Loading Criteria gosq
Wind Criteria
TCLL: 30.00
Wind Std: ASCE 7-10
TCOL: 10.00
Speed: 160 mph
SCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: C Kzt: NA
Des Ld: 50.00
Mean Height: 21.91 It
NCBCLL: 10.00
TCDL: 5.0 psf
Load Duration: 1.25
BCDL: 5.0 psf
Spacing: 24.0"
MWFRS Parallel Dist: 0 to h/2
-
C&C Dist a: 3.50 R
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x6 SP 24001-2.0E
Bot chord 2x6 SP 2400f-2.0E :61 2x4 SP
2400f-2.OE:
Webs 2x4 SP #3 :W2 2x4 SP #2:
:W4, W5 2x6 SP 2400f-2.OE:
Code I Misc Criteria
Code:FBC 2017 RES
TPI Sld: 2014
Rep Factors Used: No
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE, HIS
Bracing
(a) Continuous lateral restraint equally spaced on member.
Nailnote
Nail Schedule:0.131"x3", min. nails
Top Chord: 1 Row @12.00" o.c.
Bot Chord: 1 Row @12.00" o.c.
Webs : 1 Row @ 4" o.c.
Use equal spacing between rows and stagger nails
In each row to avoid splitting.
(1) 112" bolts maybe used for
(2) 0.131"x3", min. nails on
The Top Chord Only.
Special Loads
-(Lumber Dur.Fac =1.25
/ Plate Dur.Fac=1.25)
TC: From
134 plf at
0.20 to 134 plf at
34.80
BC: From
100 plf at
0.00 to 100 pIf at
0.20
BC: From
20 plf at
0.20 to 20 pIf at
2.83
BC: From
24 plf at
2.83 to 24 plf at
9.93
BC: From
20 plf at
9.93 to 20 plf at
16.34
BC: From
50 plf at
16.34 to 50 plf at
18.76
BC: From
20 plf at
18.76 to 20 plf at
25.07
BC: From
24 pIf at
25.07 to 24 pit at
32.17
BC: From
20 pit at
32.17 to 20 pit at
34.80
BC: From
100 pit at
34.80 to 100 pIf at
35.00
Plating Notes
All plates are 4X6 except as noted.
"WARNING^ Please thoroughly MI. the -A-1 ROOF TRUSSES
Vent' design parameters and read notes on We Truss Design Dniv ing (TDr
mmadorplatesshalibeusedforthe TDDbbevelid. MaTuss DesignE
Den/CSI Criteria
PP Deflection in too Udefl
VERT(LL): 0.461 H 903
VERT(CL): 0.790 H 527
HORZ(LL): 0.491 N -
HORZ(TL): 0.841 N -
Creep Factor: 2.0
Max TC CSI: 0.279
Max BC CSI: 0.660
Max Web CSI: 0.677
Wgt: 512.4 Ibs
10693
Fzfia-I "
♦ Maximum Reactions (Ibs)
L/# Gravity Non -Gravity
360 Loc R+ ! R- / Rh I Rw / U / RL
240 A 2750 /- I- 11799 /1092 /510
- M 2750 !- I- /1795 11092 /-
- Wind reactions based on MWFRS
A Brg Width =6.0 Min Req=1.5
M Brg Width=6.0 Min Req=1.5 -
Bearings A & M are a dgid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
VIEW Ver. 18.02.01A.0205.20
Purling,
In lieu of structural panels or
rigid calling use pudins
to laterally brace chords as follows:
Chord
Spacing(in oc)
Start(ft)
End(fl)
BC
34
0.00
2.83
BC
103
2.83
9.93
BC
120
9.93
25.07
BC
103
25.07
32.17
A - B
1088 -2730
G - H
1269 -3198
B - C
2338 -5883
H -1
1242 -3151
C - D
2864 -7208
I - J
1277 -3215
D - E
1277 -3215
J - K
2864 -7209
E-F
1242-3151
K-L
2338 -5884
F-G
1269-3197
L-M
1088 -2730
Maximum But Chord Forces Per
Ply (Ibs)
Chords
Tens.Comp.
Chords
Tens. Comp.
BC 34 32.17 35.00
A-U
2320 -923
Q-P
5355 -2125
Apply pudins to any chords above or below fillers
U-T
2646-1050
P-O
5758 -2280
at 24" OC unless shown otherwise above.
T - S
5758 -2280
O - N
2646 -1050
S-R
5355-2125
N-M
2321 -923
Wind
R-Q
1836 -731
Wind loads based on MWFRS with additional C&C member design.
Additional Notes
The maximum horizontal reaction Is 510#
GENERAL TERMS and CONDITIONS
cony T. Tombo III, P.E. Reference Steel
. Soedaltv Enoineerl. Me seal on env Tr
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
B-U
532-1254
G-Q
1777 -681
B-T
2712-1068
Q-H
159 -234
T-C
372 -828
Q-J
1193 -2984
C-S
1166 -465
J-P
3296 -1282
S - D
3296 -1282
P - K
1167 -466
D-R
1193-2984
K-O
372 -828
F - R
159 -234
O - L
2712 -1068
R-G
1776 -681
N-L
532 -1254
albuildingmdeend TPI-1. Thaapprovalorlte TDDandaoyw
aN Contredm. Mno[es set oulin the TDD end the practimse
guidance. TP4ldegnes Ueresponsibiliuesanddutiesof NeT
g by all PaNes Involved. The Truss Design Engineer Is NOT the
q „mISMVG uiIM+d pw vnin,nrarMa[NnNAt RMTn�cw-gnPumv T. train III. P.E.
A
"A A4 ROOF
Anthony T•Tombo III, P.E.
# 80083
4451 St. Lucie Blvd.
Fort Pierce, FL 34946
Job
75775
Truss Truss Type
A03G ICOMN
Qty I Ply 1 04/18/2019
10763
Loading Criteria (ppq
TCLL: 30.00
TCDL: 10.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 50.00
NCBCLL: 0.00
Load Duration: 1.25
Spacing: 24.0'
I-�e------ 4T
I--zae-1
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzb NA
Mean Height: 21.91 it
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.50 it
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Top chord 2x6 SP 2400f-2.OE
Bot chord 2x6 SP 2400f-2.0E :81 2x4 SP
2400f-2.0E:
Webs 2x4 SP #3:W2, W8 2x4 SP #2:
04, W5 2x6 SP 240Of-2.0E:
Code I Misc Criteria
Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: No
FT1RT:10(0)/10(10)
Plate Type(s):
WAVE, HS
Bracing
(a) Continuous lateral restraint equally spaced on member.
Nallnote
Nall Schedule:0.131"x3", min. nails
Top Chord: 1 Row @12.00" o.c.
Bot Chord: 1 Row @11.25"o.c.
Webs : 1 Row @ 4" o.c.
Use equal spacing between rows and stagger nails
in each row to avoid splitting.
(1)112" bolts may be used for
(2) 0.131"x3, min. nails on
The Top Chord Only.
Special Loads
--(Lumber Dur.Fac. 1.25 / Plate Dur.Fac. 1.25)
TC: From
45 plf at
0.20 to
45 plf at
11.85
TC: From
69 pit at
11.85 to
69 plf at
34.80
BC: From
85 pit at
0.00 to
85 Pf at
0.20
BC: From
20 plf at
0.20 to
20 plf at
2.83
BC: From
24 plf at
2.83 to
24 plf at
9.93
BC: From
20 pit at
9.93 to
20 pit at
16.34
BC: From
50 pit at
16.34 to
50 plf at
18.76
BC: From
20 plf at
18.76 to
20 plf at
22.08
BC: From
20 plf at
22.08 to
36 Pf at
25.07
BC: From
40 plf at
25.07 to
79 pit at
32.17
BC: From
75 plf at
32.17 to
89 plf at
34.80
BC: From
164 plf at
34.80 to
155 plf at
35.00
BC: 2277 lb Conc. Load at 22.08
De0/CSI Criteria
PP Deflection in too Udefl L#t
VERT(LL): 0.555 J 750 360
VERT(CL): 0.962 J 433 240
HORZ(LL): 0.561 N - -
HORZ(rL): 0.972 N - -
Creep Factor. 2.0
Max TC CSI: 0.466
Max BC CSI: 0.993
Max Web CSI: 0.897
Wgt: 512.4 Ibs
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- I Rh / Rw / U / RL
A 2282 /- /- 1988 11193 /510
M 3412 !- /- /1327 /1513 /-
Wind reactions based on MWFRS
A Brg Width = 6.0 Min Req = 1.5
M Brg Width = 6.0 Min Req = 1.5
Bearings A & M are a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 1227
VIEW Ver. 18.02.01A.0205.20 8-C 2765
Plating Notes C - D 3595
All plates are 6X8 except as noted. D - E 1719E - F 1694
(") 3 plate(s) require special positioning. Refer to scaled plate plot &tailsfpg2
special positioning requirements.
Pudins
In lieu of structural panels or rigid ceiling use puriins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 34 0.00 2.83
BC 103 2.83 9.93
BC 93 9.93 25.07
BC 96 25.07 32.17
BC 34 32.17 35.00
Apply pudins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS.
Additional Notes
The maximum hodzontal reaction is 510#
"WARNING" Pleasa iho.,inly W. the-A-1 ROOF TRUSSES("SELLER°), GENERAL TERMS and CONDITIONS CUSTOMER
sM of the IRC, tine IBC, local building code and TPIA.
Na IBC, local Wining coda and TPIA. The apyoval
2326
G - H
2153 -4351
5377
H -I
2136 -4333
7044
I-J
2162• -4366
3433
J - K
4831 -9923
3411
K - L
3610 -7594
3429
L- M
1567 -3396
Maximum Bet Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
A - U
1982 -1043
Q - P
7373 -3592
U - T
2260 -1184
P - O
7546 -3579
T-S
5311 -2735
O-N
3324 -1509
S - R
5289 -2690
N - M
2B96 -1333
R-Q
2221 -1105
Maximum Web Forces
Per Ply (Ibs)
Webs
Tens.Comp.
Webs
Tens. Comp.
B-U
593-1057
G-Q
3142 -1522
B - T
2657 -1346
Q - H
159 -154
T-C
460 -815
Q-J
1979 -4108
C - S
1436 -702
J - P
4758 -2257
S - D
3089 -1564
P - K
2005 -1049
D - R
1396 -2672
K - O
648 -1157
F - R
162 -151
O - L
3649 -1772
R-G
1411 -694
N-L
747 -1477
or .
A
In.p
Ineetin
'e
I
1M1�A-IRRDF
�tlTRl155E5
Ind
Anthony T. Tombo III, P.E.
nuss
# 80083
Nt ihilM WTmt Ihnw nnamI' al A,I RmITAw- A,tWv T Ta M III. P E.
r avudi,u 4451 St. Lucie Blvd.
Fort Pierce, FL 34946
Job
75775
Truss Truss Type Qty I Ply
A04 I SPEC 16 1
04/10/2019
10706
Loading Criteria (pan
TCLL: 30.00
TCDL: 10.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 50.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0"
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: ll
EXP: C Kzt: NA
Mean Height: 21.91 [t
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50
GCpI: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x6 SP #2
Bot chord 2x6 SP #2 :B1 2x4 SP #2:
Webs 2x4 SP #3
Code / Misc Criteria
Code: FSC 2017 RES
TPI Sld: 2014
Rep Factors Used: Yes
FTIRT:10(0)/10(10)
Plate Type(s):
WAVE
Bracing
(a) Continuous lateral restraint equally spaced on member.
Puriins
In lieu of structural panels or rigid ceiling use pudins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
Be 34 0.00 2.83
Be 53 2.83 9.93
Be 58 9.93 22.02
Apply pudins to any chords above or below fillers
at 24' OC unless shown otherwise above.
Loading
Truss passed check for 20 psf additional bottom chord live load in areas with
42' high x 24'-wide clearance.
Wind
Wind loads based on MWFRS with additional C&C member design.
Right end vertical not exposed to wind pressure.
-WARNING- Please thoroughly review Me-A-1ROOF TRUSSES
sty design parameters and head notes on Ihls Truss Design Drawing (ME
onaector dates shall be used forMe TDD to be valid. Asa TrussDeslan Ei
single
4M
t
Deg/CSI Criteria
♦ Maximum Reactions (Ibs)
PP Deflection in loc Udefl L#1
Gravity Nan -Gravity ,
VERT(LL): 0.251 K 999 360
Loc R+ / R- I Rh I Rw / U / RL
VERT(CL): OA29 K 611 240
A 1189 /- /- 1638 1361 1576,
HORZ(LL): 0.1461 - -
1 1214 /- /- l671 /600 !-
HORZ(TL): 0.249 1 - -
Wind reactions based on MWFRS
Creep Factor. 2.0
A Brg Width = 6.0 Min Req = 1.5
Max TC CSI: 0.405
1 Brg Width =- Min Req = -
Max Be CSI: 0.961
Bearing A is a rigid surface.
Max Web CSI: 0.955
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
Wgt 168.0 Ibs
A-B 782-2233 E-F 876 -1704
VIEW Ver. 18.02.01A.0205.20
13-C 2258-4434 F-G 1096 -1805
C-D 2677-4830 G-H 141 -116
D-E 882-1792
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A - M 1893 -1205 K - J 3732 -2274
M - L 2189 -1379 J -1 637 -308
L-K 4300-2677
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
B - M
727 -1005
D - J
1615 -2482
B - L
1867 -1135
F - J
372 -374
L-C
405 -477
J-G
1755 -1025
C-K
384 -191
G-1
542 -1115
K - D
2386 -1452
H -1
196 -198
GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACIMOWLEDGMEN tome.
ianv T.Tombolll. P.E.Reference Sheet before use. Unless odrerwlse stated on Me MD. only Ale
L min TI%tl vAeen� Itxwinq�enmu['vnNA1 RMTn�aw�e.NNNV T. TMIEII In. PE,
A-f ROOF
TRUSSES
Anthony T. Tombo, III. P.E.
# 80083
4451 St. Lucie Blvd.
Fort Pierce. FL 34946
Job Truss
75775 A05G
Truss Type
FLAT
QtY 3 I Ply I04/10/2019
10751
'
Loading Criteria (part
Wind Criteria
.
TCLL: 30.00
Wind Std: ASCE 7-10
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: C Kzt: NA
Des Ld: 50.00
Mean Height: 24.58 it
NCBCLL: 10.00
TCDL: 5.0 psf
'
Load Duration: 1.25
BCDL: 5.0 psf
Spacing: 24.0'
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50'
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x8 SP 2400f-1.8E
Bot chord 2x8 SP 24001-1.8E
Webs 2x4 SP #3
Special Loads
—(Lumber Dur.Fac =1.25 / Plate Dur.Fac. 1.25)
TC: From 405 pif at 0.00 to 405 pif at 5.00
BC: From 20 pif at 0.00 to 20 pif at 5.00
BC: 1214 Ib Conc. Load at 1.50, 3.50
I
F
BAX10(R) 03XAC
103X10 1113X10(R)
f-1'6-2' +'e I
12144 214
Code I Misc Criteria
Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: No
FT/RT:10(0v10(10)
Plate Type(s):
WAVE
Purllns
In lieu of structural panels or rigid ceiling use puriins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 60 0.00 5.00
Apply puriins to any chords above or below fillers
at 24' OC unless shown otherwise above.
The TC of this truss shall be braced with attached spans at 24' oc in lieu of
structural sheathing.
Hangers I Ties
(J) Hanger Support Required, by others
Wind
Wind loads and reactions based on MWFRS.
End verticals not exposed to wind pressure.
Additional Notes
Truss must be Installed as shown with lop chord up.
DeflICS1 Criteria
PP Deflection in loc Udell LJ#
VERT(LL): 0.004 B 999 361
VERT(CL): 0.006 B 999 241
HORZ(LL):-0.003 B - -
HORZ(TL): 0.004 B - -
Creep Factor. 2.0
Max TC CSI: 0.323
Max BC CSI: 0.540
Max Web CSI: 0.224
Wgt 44.8 Ibs
VIEW Ver. 18.02.01A0205.20
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ !R- /Rh /Rw /U /RL
D 2277 /- /- /- /1211 /-
C 2277 /- /- /- /1211 1-
Wind reactions based on MWFRS
D Brg Width = - Min Req = -
C Brg Width = - Min Req = -
Maxlmum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
A-B 7 -14
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
D-C 14 -8
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
A-D 590-1012 B-C 590 -1012
A-C 0 -1
"WARNING" Please thoroughly review Use'X1 ROOF TRUSSES("SELLER°), GENERAL TERMS and CONDTIONS CUSTOMER ('BUYER') ACKNOWLEDGMENT' rams.
edfy design rammotesa and read notes on We Truss Daslan D.Wra mom and the Anthanv T. Tambs III. P.E. Rsrerenm Shaet Mrnm uw_ Unlace arhuwlw %1ntM nn Iha TnD. nnly Air
nasan(BSCI) published by TPI and SBCAamneferenced forgenerelguldance. TPI-1 defines fbe responslbliitles and duBe9
facmren unless odleWse darned bye ConVxet agreed upon in writing by all Padies ilrvohred. The Tmss Design Engineer Is r
M cxFts ud aura ere es defused In TPI-1.
11. PE. RmuMnrM of Mies nnml N—f—Ln !!,MWIMn ff urtW oxr mnn MA4 RWTnn—n-A,I vT. Try III. PE.
'01kTR SSE9
Anthony T. Tombo III, P.E.
# 80083
4451 St. Lucie Blvd.
Fort Pierce. FL 34946
Job Tmss Truss Type Qty Ply 04/10/2019 10625
75775 B01 I GABL 11 I 1
10,11.1
I
1
Loading Criteria (pap Wind Criteria
Code I Misc Criteria Deff/CST Criteria ♦ Maximum Reactions (Its), or a=PLF
TOLL: 30.00 Wind Sld: ASCE 7.10
Code: FBC 2017 RES PP Deflection in loc Udefl L/# Gravity
Nan -Gravity
TCDL: 10.00 Speed: 160 mph
TPI Sid: 2014 VERT(LL): 0.017 M 999 360Loc R+ / R- / Rh
/ Rw / U / RL
BCLL: 0.00 Enclosure: Closed
Rep Factors Used: No VERT(CL): 0.030 M 999 24 y 337 /- /-
1208 /107 /26 -
BCDL: 10.00 Risk Category: II
FT/RT:10(0)110(10) HORZ(LL): 0.008 L - - N 901 /- /-
/632 /394 I• -
EXP: C Kzt: NA
Plate Type(s): HORZ(TL): 0.010 K - - Wind reactions based on MWFRS
Des Ld: 50.00 Mean Height: 15.00 it
WAVE Creep Factor. 2.0 Y Brg Width = 268
Min Req = -
NCBCLL: 10.00 TCDL: 5.0 psi
Max TC CSI: 0.754 N Brg Width = 8.0
Min Req = 1.5
Load Duration: 1.25 BCDL: 5.0 psf
°
Bearings Y & N are a rigid surface.
Max BC CSI: 0.336
24.0 MWFRS Parallel Dist: 0 to h/2
Bearings Y & N require
a seat plate.
C&C Dist a: 3.00 it
Max Web CSI: 0,418 -
Maximum Top Chord Forces Per Ply (Ibs)
Loc. from endwall: Any
Will:131.6 lbs Chords Tens.Comp.
Chords Tens. Comp.
GCpi: 0.18
Wind Duration: 1.60
VIEW Ver. 18.02.01A.0205.20 A-B 153 -73
H-1 974 -191
Lumber
Additional Notes B-C 710 -715
I-J 795 -149
C - D
-372
J - K -189
To chord 2x4 SP #2
The maximum horizontal reaction is 586# D-E 401 -306
K-L 417
Botchord 2x4 SP#2
See STD DETAILS for gable wind bracing requirements. E - F 609 -30fi
609
279 .182
L- M 279 -182
Webs 2x4 SP #3
:Stack Chord SC1 2x4 SP M-30:
Stacked top chord must NOT be notched or cut in area (NNL). OFopged topMr&258
M - N 500 -642
:Stack Chord SC2 2x4 SP M-30:
braced at 24' oc intervals. Attach stacked top chord (SC) to dro)fpedtop ch9din-228
N - O 153 -73
notchable area using 3x4 fle-plates 24' oc. Center plate on stacked/dropped chord
Special Loads
interface, plate length perpendicularto chord length. Splice top ANIANtAY-%ord Forces Per Ply (Ibs)
-(Lumber Dur.Fac=1.25I Plate Dur.Fac =1.25)
area using 3x6. Chords Tens.Comp.
Chords Tens. Comp.
TC: From 171 pIf at -2.00 to 171 pif at 0.00
TC: From 174 plf at 0.00 to 181 pif at 1.58
B - X 452 -195
T - S 489 -227
TC: From 331 pif at 1.58 to 370 pif at 11.50
X - W 464 -211
S - R 484 -219
TC: From 370 plf at 11.50 to 331 pif at 21.42
W - V 474 -216
R - Q 477 -210
TC: From 181 plf at 21.42 to 174 pif at 23.00
V - U 480 -222
Q - P 467 -198
TC: From 171 pIf at 23.00 to 171 pif at 25.00
U - T 489 -227
P - N 446 -178
BC: From 10 pif at 0.00 to 10 plf at 23.00
Plating Notes
Maximum Gable Forces Per Ply (Ibs)
Gables Tens.Comp.
Gables Tens. Comp.
All plates are 1.5X4 except as noted.
D - X 437 -720
S -1 607 -818
Purling
E-W 404 -670
R-J 346 -686
In lieu of structural panels or rigid ceiling use pudins
F - V 346 -686
Q - K 403 -670
to laterally brace chords as follows:
G - U 607 -818
P - L 438 -720
Chord Spacing(in oc) Start(ft) End(ft)
H-T 180 -732
TC 0 0.89 22.11
BC 75 0.29 22.71
Apply purling to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Truss designed to support 2-0-0 top chord outlookers and cladding load not to
exceed 8.00 PSF one face and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Wind
Wind loads based on MWFRS with additional C&C member
design.
-WARNING" Please Momughly review Me'A.1 ROOF TRUSSES ('SELLER'), GENERAL TERMS and CONDITIONS CUSTOMER('BUYER•) ACKNOWLEDGMENT toms.
Verify design parameters and read notes an this Truss Design Drawing (MD)
and Me An bony T. Tomb, ill, P.E. Reference, Sheet before use. Unless otherwise stated on Me MD, only Alpi
connector plates shall be used fit le TDD to be valid. MaTmss Design Engineedr o.e.Specialty Englneer),Mesealonar TDDmpresenManersepWnwof Nepmmslonalenglneerin
A ROOF
eslexcibllity for Me design of Mesingle Truss depicted on Me TOO only, underTPI-1. The design assumptions, loading conditions. suitability and use of this Truss formy Building is be
®TRD55E5
Building is Me responstbgiy date Owner, the Owners euNorized agent
or Ma Building Designer, in We conte#ef Me IRC, Me IBC, bcal building code and TPI-1. The approval of Me
rmxonmvn
responsibility ofWa Ovular, Me Owners authorized agent orthe Building
Designer, in Me content of Me IRC, Me IBC, local building code and TPl-1. Theappmvaloftna TDDandanygeld
Anthony
T•TOmbO III, P.E.
use of Me Twice, including handling. storage, installation and bred, shell be Me eserme ilbiliy of Me Building Designerarld Contractor. Allnotessetoutin Me TOOand Meprzcticesand
Na Truss
#80083
guldelines ofthe Building Component Safety Information(BSCI) published by TPl and SBCA ale, referenced forgeneral pdance. TPI-ldefi MeresponsibllNesanddutiesof
Designs, Truss Design Engineerand Tmss Manufacturer, unless otherwtsedegned bya Cantractagreed upon inwddngby all real" Involved. The Tmss Design Enginearis NOT Me Buidi
4451 St. Lucie Blvd.
DeslgnerarTmae System Engineer of any building. All repllalibed terms ere as dented in TPI-1.
r�wxioM 02I18MI RMTna AnI1v TTmm 111.PE.RmmM,nim MMutlmmw,t In env Mvm.LmYWOM WWnd tlu wlNn„n„nicxNnnr FlPmfTnuvw<-MWnvT. T�mtr, In PE
Fort Pierce. FL 34946
Job Truss Truss Type Qty Ply 04/10r2019
75775 B02 COMN 19 11 I 10636
Loading Criteria (asp
TCLL: 30.00
TCDL: 10.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 50.00
NCBCLL: 10.00
Load Duration: 1.25
Sparing: 24.0"
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
1 V6' ')11'6' �
SEAT PLATE RED. SEAT PLATE RED.
Wind Criteria
Wind Std: ASCE 7.10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 it
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 It
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Purllns
In lieu of structural panels or rigid ceiling use pudins
to laterally brace chords as follows:
Chord Spacmg(in oc) Start(ft) End(R)
BC 107 0.15 22.85
Apply pudins to any chords above or below fillers
at 24' OC unless shown otherwise above.
I
I
�—. T
Code / Misc Criteria
DeBICSI Criteria
♦ Maximum Reactions (Ibs)
Code: FBC 2017 RES
PP Deflection in roc Udefl LI#
Gravity Non -Gravity
TPI Sid: 2014
VERT(LL): 0.090 E 999 360
Loc R+ ! R- / Rh l Rw / U I RL
B 1383 /- /- /728 /435 1298
Rep Factors Used: Yes
VERT(CL): 0.147 E 999 240
FT/RT:10(0)/10(10)
HORZ(LL): 0.033 H - -
F 1383 /- /- /728 /435 /-
Plate Type(s):
HORZ(TL): 0.054 H - -
Wind reactions based on MWFRS
WAVE, HS
Creep Factor. 2.0
B Big Width = 8.0 Min Req = 1.6
Max TC CSI: 0.577
F Brg Width = 8.0 Min Req = 1.6
Max BC CSI: 0.991
Bearings B & F are a rigid surface.
Max Web CSI: 0.609
Bearings B & F require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Wgt: 109+21bs
Chords Tens.Comp. Chords Tens. Comp.
VIEW Vera 18.02.01A.0205.20
A-B 74 0 D-E 1384 -1975
B - C 1145 -2032 E - F 1144 -2032
C-D 1385-1975 F-G 74 0
Loading
Truss passed check for 20 psf additional bottom Chord live load in areas with
42"-high x 24'-wide clearance.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B-J 1708 -770 1-H 1170 -398
J-1 1170 -398 H-F 1709 -790
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
C - J 553 -461 D - H 850 -596
J - D 849 -596 H - E 553 -461
'-WARNING- Please thoroughly review Use "A-1 ROOF TRUSSES ("SELLER'), GENERAL TERMS and COMMONS CUSTOMER (-BUYER') ACgVOwLEDGMENT-form.
Vent' design parameters and read notes on this Toss Design Drawing TDD) and the Anthony T. TamCo ill, P.E.reference Sheet before use. Unless othenMse stated an she MD. any All
be
in the mntea
If the IRC, she
Us approval of the Too and any ileh
t out in the MD and the practkes end
km 11W WINW rM v ffu mnnvW MMt RWTnusav- MI —VT. Trvna Ill. P.E.
LA-/ ROOF
TR1155E5
Anthony T•Tombo III, P.E.
# 80083
4451 St. Lucie Blvd.
Fort Pierce. FL 34946
Job Truss Truss Type Qty Ply 04/10/2019 10795
75775 I B02A I COMN 11 I 1
Loading Criteria (pet)
TCLL: 30.00
TCDL: 10.00
SCLL: 0.00
BCDL: 10.00
Des Ld: 50.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 °
SEAT PLATE REO, SEAT PLATE REQ.
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 fl
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h2
C&C Dist a: 3.00 0
Loc. from endwall: Any
GCpl: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP M-30
got chord 2x4 SP M-30
Webs 2x4 SP #3
Special Loads
—(Lumber Dur.Fac =1.25 / Plate Dur.Fac. 1.25)
TC: From 132 plf at -2.00 to 132 pif at 25.00
EC: From 20 plf at 0.00 to 20 plf at 23.00
Purlins
In lieu of structural panels or rigid ceiling use pudins
to laterally brace chords as follows:
Chord Spacing(In oc) Start(ft) End(ft)
BC 100 0.15 22.85
Apply pudins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Code I Misc Criteria
Code: FBC 2017 RES
TPI Sid: 2014
Rep Factors Used: No
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE, HS
Wind
Wind loads based on MWFRS with additional C&C member design.
Additional Notes
The maximum horizontal reaction is 298#
DeflICSI Criteria
♦ Maximum Reactions (Ibs)
PP Deflection in loc L/de8
U# Gravity Non -Gravity, ,
VERT(LL): 0.103 E 999
360 Loc R+ / R. / Rh I Rw / U / RL
VERT(CL): 0.171 E 999
240 B 2017 1- /- /1403 /685 /298 -
HORZ(LL): 0.037 H -
- F 2017 /- /- /1403 /685 /-
HORZ(TL): 0.062 H -
- Wind reactions based on MWFRS
Creep Factor. 2.0
B Brg Width = 8.0 Min Req = 2.4
Max TC CSI: 0.574
F Brg Width = 8.0 Min Req = 2.4 ,
Max BC CSI: 0.975
Bearings B & F are a rigid surface.
Bearings B & F require a seat plate.
Max Web CSI: 0.608
-
Maximum Top Chord Forces Per Ply (Ibs)
Wgt• 109.2 lbs
Chorcla Tens.Comp. Chords Tens. Comp.
VIEW Ver. 18.02.01 A.0205.20
A-B 118 -53 D-E 1384 -2778
B - C 1144 -2866 E - F 1144 -2866
C-D 1384-2778 F-G 118 -53
Maximum But Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - J 2390 -769 I - H 1655 -542
J -1 1655 -542 H - F 2390 -789
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
C-J 552 -749 D-H 1148 -595
J-D 1148 -595 H-E 552 -749
-WARNING^ Please thoroughly mein the'A-1ROOF TRUSSES('SELLER'), GENERAL TERMS and CONDITIONS CUSTOMER('aUVEW) ACKNOWLEDGMENT' form.
faMy deaign parameters and read notes on this Truss Design Dmwthg (rDD) and the Anthony T. Tombo III, P.E. Reference Sheet before use. Unless othenuise stated on the TOO. only All
end TPI-1.
VaConbadagreedupon Iny Ungbyellpadlesinp . TheTruss Design Engleaeris1
n TPM.
Faminmi.NmNJNtM uiavarl nu, wriMnbmNreumN Al nmf Tn--Mau.T. Tm III. P.E.
N1 ROOF
Anthony T•Tombo III, P.E.
# 80083
4451 St. Lucie Blvd.
Fort Pierce. FL 34946
Job
75775
Truss Truss Type
B03 ATIC
1ty I Ply
104/1012019
10662
Loading Criteria (ps9
•
TCLL:
30.00
TCDL:
10.00
BCLL:
0.00
BCDL:
10.00
Des Ld: 50.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Soo
sou
r�
sEAr FLATe REo. SEAT PLATE REQ.
23'
z�-6'
Wind Criteria
Wind Std: ASCE7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: h to 2h
C&C Dist a: 3.00 IT:
Loc. from endwall: not in 9.00
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP M-30
Bot chord 2x8 SP 2400f-1.8E :B3 2x4 SP #2:
Webs 2x4 SP 43
Purlins
In lieu of structural panels or rigid ceiling use pudins
to laterally brace chords as follows:
Chord Spacing(In oc) Start(ft) End(ft)
BC 120 0.15 22.85
Apply pudins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Code I Misc Criteria
Code: FBC 2017 RES
TPI Sid: 2014
Rep Factors Used: Varies by Ld
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Collar -de braced with continuous lateral bracing at 24' Do. or rigid ceiling
Loading
Live loads applied in combination per ASCE 7 sec. 2.4.1 use 0.75 factor for multiple
live loads.
BC storage loading: LL = 30.00 psf, DL = 0.00 psf; from 6-0-0 to 17-0-0.
Mechanical Unit Loads Supported by this Truss
At Truss Unit Unit Supporting
X-Loc Piece Lbs. Width Trusses
8.00 TC 100.0 2.00 2
Wind
Wind loads based on MWFRS with additional C&C member design.
i
i
1'
V 1 ---
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
PP Deflection in loc
L/defl L/# Gravity Non -Gravity
VERT(LL): 0.330 D
825 360 Loc R+ / R- / Rh / Rw / U / RL
.�ERT(CL): 6.565 D
482 240 O 1487 /- /- /729 /181 /298
HORZ(LL): 0.151 D
- - J 1487 /- /- 1729 /181 /-
HORZ(TL): 0.264 D
- - Wind reactions based on MWFRS
Creep Factor. 2.0
0 Brg Width = 8.0 Min Req = 1.5
Max TC CSI: 0.998
J Brg Width = 8.0 Min Req = 1.5
Max SC CSI: 0.992
Bearings O & J are a rigid surface.
Max Web CST: 0.394
Bearings O & J require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Wgt: 141A lee
Chords Tens.Comp. Chords Tens. Comp.
VIEW Ver. 18.02.01A.0205.20 A-B 74 0 F-G 214 -162
B - C 708 -2651 G - H 660 -1850
C - D 644 -2296 H -1 643 -2296
D-E 661 -1850 I-J 707 -2651
E-F 214 -162 J-K 74 0
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B-M 2363 -471 L-J 2363 -491
M-L 1826 -333 -
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
C-M 201 -653 N-G 543 -1974
M-D 841 -28 H-L 841 -30
E-N 543-1974 L-I 201 -653
F-N 189 -50
-WARNING- Please lhamughly reWew the -A-1 ROOF TRUSSES("SELLER', GENERAL TERMS and CONDITIONS CUSTOMER('BU`(ER7) ACKNOWLEDGMENT" form.
only design paramete,s and read notes on this Trans Design Drawing(rDD) and the Anthony T. Tombo ill, P.E. Reference Sheet before use. unless cNenWse slated on Me Too, a* Ali
Dnnertor plates shell be used for Me TDD to be v Nd. As a Truss Design Engineering (i.e. Si Engineer), Me seal many TDD represents an arseptence of Me professional englueen
aponsibiliry for Me design of the single Tress derided on Me TOO only, under TPI-1. The design assumptions, loading wndifions, suitability and use arable Trues forany Building Is the
uilding is the responsibility ofthe Owner, Me Owners authanued agent., the Building Designer, in Me mntedefthe IRC, Me IBC, local building code and TPI-1. Thempmvalof Me
aMnsibility of the Owner, Me Owners suawdead agent w Me Building Designer, In Me tooted of the IRC. the IBC. 1=1 building code and TPM. The amnoval of Me TOO and env geld
All notes net outin Me TDD and Me oadoes and
viewAlAewnXnn mm,iuim NMf RWTrt-AnawrvT.Try III.PE.
e
A-f ROOF
TAO55E5
Anthony T•Tombo III, P.E.
480083
4451 St. Lucie Blvd.
Fort Pierce. FL 34946
Job
75775
Truss Truss Type
B04 I ATIC
Oty Ply
4 I1
04/11/2019
11073
Loading Criteria (asit
TCLL: 30.00
TCDL: 10.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 50.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0'
Z
lifr�
.10x10 s1axio
SE4TfMTE REQ. SEAT PLATE REQ
Wind Criteria
Wind Sld: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height 15.00 ft
TCDL: 5.0 psf
BCDL: 5.0 lost
MWFRS Parallel Dist: It to 2h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00
GCpi: 0.18
Wind Duration: 1.60
Top chord 2x4 SP 2400f-2.OE
Bot chord 2x8 SP 24001-1.8E :B3 2x4 SP #2:
Webs 2x4 SP #3
Purling,
In lieu of structural panels or rigid ceiling use putting
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.15 22.85
Apply pudins to any chords above or below fillers
at 24' OC unless shown otherwise above.
Code / Misc Criteria
Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Varies by Ld
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Collar -tie braced with continuous lateral bracing at 24' oc. or rigid ceiling
Loading
Live loads applied in combination per ASCE 7 sec. 2.4.1 use 0.75 factor for multiple
live loads.
BC storage loading: LL = 30.00 psf; OL = 0.00 Pat,, from 6-0-0 to 17-0-0.
Mechanical Unit Loads Supported by this Truss
At Truss Unit Unit
Supporting
X-Lac Piece Lbs. Width
Trusses
8.00 TC 100.0 2.00
2
Wind
Wind loads based on MWFRS with additional C&C member design.
DeflICSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.296 C 921 361
$>ERT(CL): 0.523 C 521 241
HORZ(LL): 0.136 C - -
HORZ(TL): 0.245 C - -
Creep Factor. 2.0
Max TC CSI: 6.908
Max BC CSI: 0.996
Max Web CSI: 0.408
Wgt: 135.81bs
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ ! R- / Rh l Rw 1 U / RL
M 1352 1- 1- /577 /149 1221.
1 1352 1• l- /577 1149 1-
Wind reactions based on MWFRS
M Brg Width =8.0 Min Req=1.5
1 Brg Width =8.0 Min Req=1.6
Bearings M & I are a rigid surface.
Bearings M & I require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
VIEWVer.18.02.01A.0205.20 A-B 870-2754 E-F 221 -146
B - C 757 -2381 F - G 728 -1905
C - D 728 -1905 G - H 757 -2381
D - E 221 -146 H - 1 870 -2754
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A - K 2461 -698 J -1 2461 - 697
K-J 1888 -466
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
B-K 291 -696 L-F 646 -2055
K-C 873 -88 G-J 873 -88
D - L 645 -2055 J - H 291 -696
E-L 196 -60
"WARNING" Please thoroughly review the -A-1 ROOF TRUSSES('SELLER'), GENERAL TERMS and CONDITIONS CUSTOMER('BUYER') ACKNOWLEDGMENT'form.
'edify design parameters and food notes w this Truss Design DrevAng (TDD) and rue Anthony T. Taoist III, P.E. Referenco Sheet before use. Unless otherwise stated on the TDD, onlyA¢
onnectorplates shall W used for the Too W W valid. As a Truss Design Engineering (i.e. Spedalty Engineer), the seal on any TOD represents an accoplanre of the professional engineer
ssponsiblityfor the design state single Truss depicted on the Too only, underTi The design assumptions. loading conditions, suitability and use of Mis Truss Warty Budding is rue
lulldmg is the responsibility alone Owner, the Owner's authorized agent orthe Building Designer, in rue cordent ofthe lRG the IBC, so l budding code and Ti Theappmvoloftha
asponsibility, of the Owner, one Owners authorized agent or Me Building Designer, In 0e context of rue IRC, be IBC, local building ones and TPI-1. The approval of the TDD end anygeld
seofthe Truss, Indudirg handling,storage, ustallatlan and Wool shall he be responsibility ofthe Building Designer and Contractor. Allnoteswtautinone TDDand Napmc ,and
uidellnes .1Ne Building Component Safetylnfonnadon (BSCI) WdLshed by TPI and SBCA ere referenced for general guidance. TPI-1 defines the responsfalilies and does of the Truss
resigner, Truss Design Engineer and Truss Manufacturer, unless observes defined by a Contract agreed upon in venting by A] panes involved. The Truss Design Engineer Is NOT the Buil,
les Liner or Toss System Engineer of any Wilding. Art esphelzed tornado as defined In TPI-1.
' tOM1e A-1RWTnu .Mtl T.Tt III. PE. RwMwYn Nouscla x,t hxmtmm.krM,Wedl WtMd flewlnx, rwmJaYm N Ml RmfTnuw-AnnmvT hmM III. P.E.
A-r ROOF
TRU55E5
Anthony T. Tombo III, P.E.
# 80083
4451 St. Lucie Blvd.
Fort Pierce. FL 34946
Job
75775
Truss Truss Type
B05G ICOMN
1ty 1y 104/11/2019
3
11064
Loading Criteria(pag
-
TCLL:
30.00
TCDL:
10.00
-
13CLL:
0.00
BCDL:
10.00
Des Ld: 50.00
NCBCLL: 0.00
Load Duration: 1.25
Spacing: 24.0'
11Y
uwn4 - 11114(at) atuxio a141014(+4) M4X4
SEATPLATEREe.
SEAT PLATE REQ.
~•175 1-F---�:�---2 �(- 2 �-- Z 9 2 -�--- 2 9-I- 2' 2' 2 -�- 2 -I-1 T-4 -�
86 0t a6340 653f1 928# 2 3,1540 J45d
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzb NA
Mean Height: 15.00It
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpI: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP M-30
Bot chord 2x8 SP 2400f-1.8E
Webs 2x4 SP #3:W3 2x4 SP 42:
05 2x4 SP M-30:
Code I Misc Criteria
Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE, HS
Bracing
(a) Continuous lateral restraint equally spaced on member.
Nallnote
Nall Schedule:0.131"x3', min. nails
Top Chord: 1 Row @12.00" o.c.
Bot Chord: 2 Rows @ 3.00" o.c. (Each Row)
Webs : 1 Row @ 4" o.c.
Repeat nailing as each layer is applied. Use equal
spacing between rows and stagger nails in each row
to avoid splitting.
(1) 112" bolts may be used for
(2) 0.131"x3", min. nails on
The Bottom Chord Only.
Special Loads
-(Lumber Dur.Fac=1.25I Plate Dur.Fac=1.25)
TC: From 82 pit at 0.00 to 82 plf at 23.00
BC: From 65 plf at 0.00 to 65 plf at 2.67
BC: From 1008 plf at 2.67 to1008 plf at 23.00
BC: 863 lb Conc. Load at 1 A0, 3.40, 6.40, 7.40
BC: 2750 lb Conc. Load at 2.13
BC: 928 lb Conc. Load at 9.40,11.40,13AO
BC: 345 lb Conc. Load at 15.40,17.40,19.40,21.40
Plating Notes
(++) - This plate works for both joints covered.
Wind
Wind loads and reactions based on MWFRS.
DeflICSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.293 K 929 36(
VERT(CL): 0.506 K 539 24(
HORZ(LL): 0.081 H - -
HORZ(TL): 0.139 H - -
Creep Factor. 2.0
Max TC CSI: 0.955
Max BC CSI: 0.768
Max Web CSI: 0.855
Wgt: 462.0 Ibs
VIEW Ver. 18.02.01 A.0205.20
Purlins
In lieu of structural panels or rigid ceiling use pudins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.15 22.85
Apply puriins to any chords above or below fillers
at 24" OC unless shown otherwise above.
"WARNING" Please thoroughly mMew the-A-1ROOF TRUSSES ('SELLER'). GENERAL TERMS and CONOI
ratty design parameters and rand notes on this Truss Design Drawing (Too) and the Amhany T. Tombo III, P.E. Refon nc
onnector plates sMll be used forthe TDD to be valid. As a Truss Design Eyireaft (i.e. SWolalty Engineer), Ne seal an
oNenNse
Ne aulldina Deshner arW ContreGor. All notes set eulin Me TDO
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ IR- /Rh IRw /U /RL
O 17147 /- /- /- /5310 /-
G 15781 /- /- /- /4851 I -
Wind reactions based on MWFRS
O Brig Width = 8.0 Min Req = 4.7
G Brg Width = 8.0 Min Req = 4.4
Bearings O & G are a rigid surface.
Bearings O & G require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Camp.
A - B 3455� 11098 D - E 2073 -6676
B - C 3140-10108 E - F 2897 -9388
C - D 2073 -6677 F - G 2994 -9728
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
A - N 9926 -3090 K - J 8212 -2534
N - M 9874 -3074 J -1 8692 -2677
M - L 9874 -3074 1- H 8692 -2677
L - K 8811 -2736 H - G 8707 -2680
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
N-B
644 -195
K-E
779 -2544
B-L
280 -868
E-J
2242 -656
L-C
2865 -866
J-F
100 -314
C-K
1006-3217
F-H
182 -61
D - K
5764 -1752
n,MIhWMthMd,MwV mrmiuMNAA RMTni-MtemrT.T=M III. PE.
4
A -I ROOF
TRU55E5
Anthony T. Tombo 111, P.E.
# 80083
4461 St. Lucie Blvd.
Fort Pierce, FL 34946
Job
75775
Truss
C01
Truss Type Qty I Ply
GABL 11 1
04/10/2019
10805
Loading Criteria (psn
TCLL: 30.00
TCDL: 10.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 50.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 °
I- z'o-12 --Al
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code: FBC 2017 RES
TPI Sld: 2014
Rep Factors Used: No
FT/RTAO(0Y10(10)
Plate Type(s):
WAVE
0'6'8
Deb/CSI Criteria
PP Deflection in loc Well L/#
VERT(LL):-0.010 B 999 36(
VERT(CL): 0.009 B 999 24(
HORZ(LL):-0.024 H - -
HORZ(TL): 0.025 H - -
Creep Factor. 2.0
Max TC CSI: 0.928
Max BC CSI: 0.075
Max Web CST: 0.566
Will: 83.3 lbs
VIEW Ver. 18.02.01A.0205.20
I
I
TE RED.
♦ Maximum Reactions (Ibs), or'=PLF '
Gravity Nan -Gravity
Loc R+ / R- / Rh / Rw / U / RL
P' 370 /- P /233 1252 /61 -
J 84 /- P /43/-
O /-309
Wind reactions based on MWFRS
P Brg Width = 131 Min Req = -
J Brg Width =0.8 Min Req=1.5
Bearings P & J are a rigid surface.
Bearings P & J require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
Lumber
Wind A-B 121 -57
E-F
98
-521
13-C 309 .197
F-G
81
-402
Top chord 2x4 SP 2400f-2.0E :T1 2x4 SP #2:
Wind loads based on MWFRS with additional C&C member des On.D 341 -100
G - H
94
-293
Bot chord 2x4 SP
Left end vertical exposed to wind pressure. Deflection meets L/3CU D 185 -972
H -1
84
-127
Webs 2x4 SP #3:M1 2x6 SP #2:
We
Right end vertical not exposed to wind pressure. D - E 80 -523
Special Loads
Additional Notes Maximum Bat Chord Forces Per
Ply (Ibs)
-(Lumber Dur.Fac =1.25 / Plate Dur.Fac=1.25)
The maximum horizontal reaction is 1067# Chords Tens.Comp.
Chords
Tens. Comp.
TC: From 168 plf at -2.06 to 168 plf at
0.00
See STD DETAILS for gable wind bracing requirements. P - O 339 -1217 M - L 16 -12
TC: From 343 pill at 1.78 to 193 pit at
TC: From 310 pill at 1.78 to 365 plf al
1.78
11.00
00
Stacked top chord must NOT be notched or cut in area (NNL �pppd topSigirch 135 L - K 9 -7
dro
BC: From 10 plf at 0.00 to 10 pit at
11.00
braced at 24' oc intervals. Attach stacked top chord (SC) to a op cho In -19 K - J 4 -5
chord
notchable area using 3x4 fie -plates 24" Do. Center plate on stacked/dropped
PlatingNotes
interface, plate length perpendicular to chord length. Splice top chord in notchable
Maximum Web Forces Per Ply (Ibs)
area using 3x6.
All plates are 1.SX4 except as noted.
++Anchorage req'd to prevent truss from slipping off bearing. Webs Tens.Comp.
('•)1 plate(s) require special positioning. Refer to scaled
plate plot details for C- N 1901 -519
special positioning requirements.
Purllns
In lieu of structural panels or rigid ceiling use pudins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 0 0.46 11.00
BC 120 0.00 11.00
Apply pudins to any chords above or below fillers
at 24' OC unless shown otherwise above.
Loading
Truss designed to support 2-M top chord outiookers and cladding load not to
exceed 8.00 PSF one face and 24.0' span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Maximum Gable Forces Per Ply (Ibs)
Gables Tens.Comp. Gables Tens. Comp.
P - B 1749 -1002 G - L 512 -692
O-C 618-1974 H-K 590 -800
N - E 337 -520 1- J 238 -307
F - M 569 -736
"WARNING" Please thoroughly review the 'A-1 ROOF TRUSSES("SELLER'), GENERALTERMS and CONDITIONS CUSTOMER ("BUYER') ACKNOWLEDGMENP tmm.
edty design parameters and read notes on this Trues Design Drawing Cron) and the Anthony T. Torahs ill, P.E. Reference Sheet before use. Unless othenalse stated on Ole MD. only Alp
and bradng shall
(BSCI) puNlshod
a Contract agreed
SW.ixwa-AnaunvT.Tm III.P.E.
A-1 ROOF
TR055E5
Anthony T•Tombo III, P.E.
480083 .
4451 St. Lucie Blvd.
Fort Pierce. FL 34946
Job
75775
Truss Truss Type P
CO2 (MONO IQ51y
I1ly
04/10/2019
10786
Loading Criteria (asq
• TCLL: 30.00
TCDL: 10.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 50.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0'
T
fV
1
SEAT PLATE RED.
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 it
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3 :W1 2x6 SP #2:
Purling
In lieu of structural panels or rigid ceiling use pudins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.00 11.00
Apply pudins to any chords above or below fillers
at 24' OC unless shown otherwise above.
Hangers I Ties
(J) Hanger Support Required, by others
Code I Mist; Criteria
Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Wind
Wind loads based on MWFRS with additional C&C member design.
Left end vertical exposed to wind pressure. Deflection meets L/360.
Right end vertical not exposed to wind pressure.
-WARNING•• Please thoroughly review the "A-1 ROOF TRUSSES
an the
Defl/CSI Criteria
PP Deflection in loc Udefl L/#
VERT(LL): 0.010 C 999 361
VERT(CL): 0.016 C 999 241
HORZ(LL):-0.004 C - -
HORZ(TL): 0.004 E - -
Creep Factor. 2.0
Max TC CSI: 0.646
Max BC CSI: 0.509
Max Web CSI: 0.454
Wgt: 74.9 Ibs
VIEW Ver. 18.02.01A.0205.20
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ IR- /Rh /Rw /U !RL
G 737 !- /- /400 /189 1288
E 539 /- !- 1311 1253 !-
Wind reactions based on MWFRS
G Brg Width = 7.3 Min Req = 1.5
E Brg Width =- Min Req = -
Bearing G is a rigid surface.
Bearing G requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 47 0 C-D 48 -96
B-C 258 -509
Maximum Bat Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
G-F 112 -470 F-E 434 -507
Maximum Web Forces Per Ply (Ibs)
Webs
Tens.Comp.
Webs
Tens. Comp.
B-G
676 -692
C-E
631 -541
B-F
457 -83
D-E
285 -171
F-C
149 -56
GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER') ACKNOWLEDGMENT" forth.
cony T.Tombolll, P.E. Reference Sheet berm use. Unless other se stated on the TOD, only All
Rm Tn.—An.T. Tanho III. P E.
e
111110��TRdJROE5
Anthony T. Tombo III, P.E.
# 80083
4451 St. Lucie Blvd.
Fort Pierce. FL 34946
Job
75775
Truss Truss Type
CO2A (MONO
City I ,)y 104/11/2019
10789
Loading Criteria (pA
TCLL: 30.00
TCDL: 10.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 50.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0'
SEAT PLATE REQ.
I- 2'0'12 -I
Wind Criteria
Wind Std: ASCE7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: ll
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP M-30
Bot chord 2x4 SP #2
Webs 2x4 SP #3 :W1 2x6 SP #2:
Special Loads
—(Lumber Dur.Fac=1.25I Plate Dur.Fac =1.25)
TC: From 131 plf at -2.06 to 131 plf at 11.00
BC: From 20 plf at 0.00 to 20 plf at 11.00
Purling
In lieu of structural panels or rigid ceiling use purling
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.00 11.00
Apply purling to any chords above or below fillers
at 24' OC unless shown otherwise above.
Hangers 1 Ties
(J) Hanger Support Required, by others
I
20
rn
Code / Misc Criteria
DefI1CSl Criteria
♦ Maximum Reactions (Ibs) ^
Code: FBC 2017 RES
PP Deflection in loc Udefl
L1# Gravity Non -Gravity -
TPI Std: 2014
VERT(LL): 0.014 C 999
360 Loc R+ / R- / Rh I Rw 1 U 1 RL
Rep Factors Used: No
VERT(CL): 0.023 C 999
240 G 1125 /- ^ !- 1'/88 1411 1288 -
FT/RT:10(0)/10(10)
HORZ(LL):-0.004 D -
- E 804 !- !- 1576 1264 1-
Plate Type(s):
HORZ(TL): 0.006 E -
- Wind reactions based on MWFRS
WAVE
Creep Factor. 2.0
G Big Width = 7.3 Min Req = 1.5
Max TCCSI: 0.610
E Big Width= - Min Req=-
Max BC CSI: 0.581
Bearing G is a rigid surface.
Max Web CSI: 0.678
Bearing G requires a seat plate.
Maximum Top Chord Farces Per Ply (Ibs)
Wgt: 74.9 lbs
Chords Tens.Comp. Chords Tens. Comp.
VIEW Ver. 18.02.01A.0205.20 A-B 76 -35 C-D 78 -141
B - C 258 -762
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
G-F 117 -470 F-E 648 -507
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
B - G 676 -1078 C - E 631 -807
B-F 681 -221 D-E 285 -277
F-C 158 -148
Wind
Wind loads based on MWFRS with additional C&C member design.
Left end vertical exposed to wind pressure. Deflection meets L1360.
Right end vertical not exposed to wind pressure.
Additional Notes
The maximum horizontal reaction is 567#
"WARNING** Please lhaaughly review due-A-1ROOF TRUSSESCSELLER'7, GENERAL TERMS and CONDITIONS CUSTOMER(-BUYEW) ACKNOWLEDGMENT'fomi.
edfy design parameters and raetl notes an this Truss Design Draining TOO) and the A hrhy T. Tombo 111, P.E. Reference Sheet before use. Unless oNerwisestated on the TDD, only Np
annector plates shall he used for the TDD to be valid M a Truss Design Engineering p.e. Spadaly, Engineer), the seal on any TDD represents an acceptensa of the professional engineery
sponsiblliyfor fire design of Ne single Truss depleted on fire TDD only, under TPM. The tlesign assumptions, loading wedbans, sultabiliy and use of Nis Truss Won, Building is fire
uiltline la ihw,wsmnsihitiN el Ne Wmcr. thw Owneta wulM1nmed anent er Ne BWtlino Oesiamr. in da mnha�I of Me IRG the IeC. oral builCm rode eM TPI-1. The aoarowal offhe
reli p.N.Involved. The Truss D.ign Eginmr is I
mmnceMn M0.1 aMTn.-An.-vT. Tvntn he PE.
A -I ROOF
TRUSaim
Anthony T•Tombo III, P.E.
# 80083
4451 St. Lucie Blvd.
Fort Pierce. FL 34946
Job Truss
75775 1 MVA
Truss Type Oty Ply
GABL 11 11
04/11/2019
10609
Loading Criteria (p ri
Wind Criteria
• TCLL: 30.00
Wind Std: ASCE 7-10
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP:C Kzt. NA
Des Ld: 50.00
Mean Height: 15.00 ft
_ NCBCLL: 10.00
TCDL: 5.0 psf
Load Duration: 1.25
BCDL: 5.0 psf
Spacing: 24.0
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00It
Loc. from endwall: Any
GCpl: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2
-
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Special Loads
—(Lumber Dur.Fac =1.25 / Plate Dur.Fac=1.25)
TC: From 312 pill at
0.00 to 351 plf at 7.44
BC: From 176 plf at
-0.44 to 176 plf at 0.00
BC: From 10 plf at
0.00 to 10 plf at 7.44
Plating Notes
All plates are 3X4 except as noted.
Purilns
In lieu of structural panels
or rigid ceiling use pudins
to laterally brace chords as follows:
Chord Spacing(in
oc) Start(ft) End(ft)
BC 95
0.00 7.88
Apply pudins to any chords
above or below fillers
at 24' OC unless shown otherwise above.
Code I Misc Criteria
Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: No
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Loading
Truss designed to support 2-0-0 top chord outlookers and cladding load not to
exceed 8.00 PSF one face and 24.0' span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Wind
Wind loads based on MWFRS with additional C&C member design.
Right end vertical not exposed to wind pressure.
Additional Notes
The maximum horizontal reaction is 1010#
See STD DETAILS for gable wind bracing requirements.
T&4 -I
E
Deb/CSI Criteria
PP Deflection in loc Udeft L/#
VERT(LL): -0.005 D 999 361
VERT(CL): 0.005 D 999 241
HORZ(LL):-0.024 D - -
HORZ(TL): 0.025 D - -
Creep Factor: 2.0
Max TC CSI: 0.302
Max BC CSI: 0.254
Max Web CSI: 0.261
Wgt: 42.0 Ibs
VIEW Ver. 18.02.01A.0205.20
♦ Maximum Reactions (Ibs), or'=PLF
Gravity Non -Gravity
Loc R+ I R- / Rh I Rw / U / RL
J' 312 I- /- /221 1312 /120
Wind reactions based on MWFRS
J Brg Width = 100 Min Req = -
Bearing A is a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A - B 255 -1073 C - D 204 -589
B-C 258 -913 D-E 164 -248
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A - I 977 -204 H - G 1002 -224
I-H 991 -217 G-F 1009 -228
Maximum Gable Forces Per Ply (Ibs)
Gables Tens.Comp. Gables Tens. Comp.
B-I 707 -5% D-G 1012 -759
C - H 902 -639 E - F 393 -299
'WARNING- Please thoroughly review the -A-1 ROOF TRUSSES ('SELLER), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER') ACKNOWLEDGMENT° term.
vent' design parameters and rand notes an Nls Tmss Deslgn Drawing CMD) and the Anthanv T. Tombo ill, P.E.Refinance Sheet before use. Unless othanxins salad! an the IDD. only Ah
d rvMTlltl WIMae tlavnnm mmM1Wnn of Mt Rml Tn,w•-AnIMmT. To nM H. PE
e
eAhAA-1 ROOF
TRU55Eg
Anthony T. Tombo III, P.E.
# 80083
4451 St. Lucie Blvd.
Fort Pierce, FL 34946
Job Truss
75775 1 MVB
Truss Type City Ply
VAL I 1 1 1
04/11/2019
10612
T4•T
Loading Criteria (psi)
Wind Criteria
Code I Misc Criteria
DeflIC81 Criteria
♦ Maximum Reactions (Ibs), or •=PLF
TCLL: 30.00
Wind Std: ASCE 7-10
Code: FBC 2017 RES
PP Deflection in loc Udefl
L14
Gravity Non -Gravity, -
TCDL: 10.00
Speed: 160 mph
TPI Sid: 2014
VERT(LL): -0.003 E 999
360
Loc R+ / R- / Rh I Rw / U I RL
D' 151 /- f- Jill /48 133 .
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: No
VERT(CL):-0.005 E 999
240
BCDL: 10.00
Risk Category: II
FT/RT:10(0Y10(10)
HORZ(LL):-0.005 C -
-
Wind reactions based on MWFRS
EXP: C Kzt: NA
Plate Type(s):
HORZ(TL): 0.006 C -
-
D Big Width = 88.4 Min Req = -
Des Ld: 50.00
Mean Height: 15.00 it
WAVE
Creep Fodor. 2.0
Bearing A is a rigid surface.
9
NCBCLL: 10.00
TCDL: 5.0 psf
Max TC CSI: 0.993
Maximum Top Chord Forces Per Ply (Ibs) -
Load Duration: 1.25
BCDL: 5.0 psf
Max BC CSI: 0.266
Chords Tens.Comp. Chords Tens. Comp.
Spacing:24.0 °
MWFRS Parallel Dist: 0 to h/2
A- B 196 -409 B - C 156 -233
CRC Dist a: 3.00 it
Max Web CSI: 0.151
Loc. from endwall: Any
Wgb 32.21bs
GCpi: 0.18
Maximum Bat Chord Forces Per Ply (Ibs)
Wind Duration: 1.60
VIEW Ver. 18.02.01A.0205.20
Chords Tens.Comp. Chords Tens. Comp.
Lumber
A-E 330 -90 E-D 346 -107
Top chord 2x4 SP #2
Bot chord 2x4 #2
Maximum Web Forces Per Ply (Ibs)
Webs 2x4 SP #3
We
Webs Tens.Comp. Webs Tens. Comp.
Special Loads
B-E 508 -717 C-D 205 -281
—(Lumber Dur.Fac =1.25I Plate Dur.Fac=1.25)
TC: From 134 plf at 0.43 to 134 plf at 7.37
BC: From 100 plf at 0.00 to 100 plf at 0.43
BC: From 20 pit at 0.43 to 20 plf at 7.37
Purlins
In lieu of structural panels or rigid ceiling use pudins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 88 0.00 7.37
Apply purlins to any chords above or below fillers
at 24' OC unless shown otherwise above.
Wnd
Wind loads based on MWFRS with additional C&C member design.
Right end vertical not exposed to wind pressure.
Additional Notes
The maximum horizontal reaction is 346#
See STD DETAILS for valley details.
"WARNING" Please Momughly review Ne-A-i
rX
in
TERMS and CONDITIONS CUSTOMER (-BUYER') AC10N0w1EDGMPNT' loin.
bo III, P.E. Reference Sheet before use. Unless oNervAse stated on the TDD, only Atl
actagreedupon1nwfirgbyailpardm Inw . TheTruss Design EngineerisI
M nNYMM Wtiv°,IIMwb�n mm°cvY,nNAt Rm Tft rt—A VT.T+ III. PE.
'AAW 5E5
Anthony T•Tombo III, P.E.
# 80083
4451 St. Lucie Blvd.
Fort Pierce. FL 34946
Job Truss
75775 I MVC
Truss Type
VAL
try y I oanlnols
1
10568
Loading Criteria (psq
Wind Criteria
TCLL: 30.00
Wind Std: ASCE 7-10
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: C Kzh NA
Des Ld: 50.00
Mean Height' 15.00 ft
NCBCLL: 10.00
TCDL: 5.0 psf
Load Duration: 1.25
BCDL: 5.0 psf
Spacing: 24.0 °
MWFRS Parallel Dist: 0 to hn
C&C Dist a: 3.00 ft
Loc. from endwall: not In 4.501
GCpi: 0.18
Wind Duration: 1.60
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Purling
In lieu of structural panels or rigid ceiling use putting
to laterally brace chords as follows:
Chord Spacmg(in oc) Start(ft) End(ft)
BC 70 0.00 5.87
Apply pudins to any chords above or below fillers
at 24' OC unless shown otherwise above.
3I 5'5'4�
Code I Misc Criteria
Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FTIRT:10(0)/10(10)
Plate Type(s):
WAVE
Wind
Wind loads based on MWFRS with additional C&C member design.
Right end vertical not exposed to wind pressure.
Additional Notes
See STD DETAILS for valley details.
I
1
DeflICSI Criteria
PP Deflection in loc Udell L#I
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.015 C - -
HORZ(TL): 0.025 C -
Creep Factor. 2.0
Max TC CSI: 0.587
Max BC CSI: 0.471
Max Web CSI: 0.215
Wgt: 23.8 Ibs
VIEW Ver. 18.02.01A.0205.20
♦ Maximum Reactions (Ibs), or •=PLF
Gravity Non -Gravity
Loc R+ / R- ! Rh I Rw / U ! RL
Ce 104 /- /- /64 128 /32
Wind reactions based on MWFRS
C Brg Width = 70.4 Min Req = -
Bearing A is a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
A-B 97 -145
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
A-C 244 -73
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp.
B - C 224 -205
"WARNING" Please thoreughlyrevlawihe'A-1 ROOF TRUSSES ("SELLER',GENERALTERMSend CONDITIONS CUSTOMER (°BUYER')ACKNOVY1EDGMENT'faml.
'wiry design parameters and read notes on this Truss Design Drawing (TDD) and me Mmony T. Tonal III, P.E. Reference Sheet before use. Unless ollrenxiss stated on me MO. only Alp
onneclor plates shallbe used for the TDD u be varM. As a Truss Design Englimenng (i.e. Specialty Engineer), me seal many Too represents an meepti of me professional engineeni
isponsibllity forth desgn of me single Truss depleted an the TDD only, under TPI-1. The design essumptons, loading conditions, suitebgHy and use of this Truss far any Building Is me
vilding is me responsiblliyofthe Owner, me Ownefs motherhood agent orthe Building Designer, in the mntaidefffe IRC, me IBC, kcal building code and TPI-1. Theappmvaloftha
eiparrsumiy, of the Chimer, the Ownees maksmed agent ate Building Designer, in ore context arms IRC, me IBC, local building We and TPI-I. The appmval of ee Too and any geld
se argue Tml including handling, storage, Installation and baring shall be the responsibility arms Balding Designer and Contractor. All notes set out le ale TDD and the pacdces end
mdefnos arms Building Component Safety Information(BSCI) published by TPI and SBCA ere referenced for general guidance. TPI-1 defines me responsibilities and duties arms Tmss
resigner, Tress Design Engineerand Tons Manufacturer, unless orherwlss defined bya Conbad agreed upon in writing by all parties Involved. The Truss Design Engineer is NOT me Bulk
^migner w Tmes System Emineerof any Witding. All aapltall:ed lama ere as darned in TPI-1.
wNrb]a1fl MtRMTnra-wx-MHrvry T.TrvnM III.PE. RxrnNivtim NgMMmm�N.in:svlmm dmmNNtMeiMnnIMwwnnc .WnNA1 Rml Tnnuu-MIMnvT TrmMIII.PE.
.409 A-1 ROOF
TRRUSSES
Anthony T•Tombo III, P.E.
# 80083
4451 St. Lucie Blvd.
Fort Pierce, FL 34946
Job Truss Iwas Type Ury I Fly U4/11/ZUIU
75775 MVD VAL 1 1 10571
Loading Criteria gup
Wind Criteria
TCLL: 30.00
Wind Std: ASCE 7-10
TCDL: 10.00
Speed: 160 mph
SCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: C Kzt: NA
Des Ld: 50.00
Mean Height: 15.00 it
NCBCLL: 10.00
TCDL: 5.0 psf
Load Duratton: 1.25
BCDL: 5.0 psf
Spacing: 24.0"
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.00 it
Loc. from endwall: not in 4.50
GCpl: 0.18 ,
Wind Duration: 1.60
Top chord 2x4 SP #2
Bol chord 2x4 SP #2
Webs 2x4 SP #3
Puriins
In lieu of structural panels or rigid ceiling use pudins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
SC 52 0.00 4.37
Apply pudins to any chords above or below fillers
at 24' OC unless shown otherwise above.
i
1
i 44'7
i4'0"15
f'
e
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs), or `=PLF
Code: FBC 2017 RES
PP Deflection in loc L/defl L1#
Gravity Non -Gravity ,
TPI Sid: 2014
VERT(LL): NA
Loc R+ / R- / Rh / Rw / U / RL
Rep Factors Used: Yes
VERT(CL): NA
C` 104 /- /- /62 126 131 -
FT/RT:10(Ov10(10)
HORZ(LL): 0.006 C - -
Wind reactions based on MWFRS
Plate Type(s):
HORZ(TL): 0.010 C - -
C Brg Width = 52.4 Min Req = -
WAVE
Creep Factor. 2.0
Bearing A is a rigid surface.
Max TC CSI: 0.300
Maximum Top Chord Forces Per Ply (Ibs)
Max BC CSI: 0.213
Chords Tens.Comp.
Max Web CSI: 0.109
A-B 74 -108
Wind
Wind loads based on MWFRS with additional C&C member design.
Right end vertical not exposed to wind pressure.
Additional Notes
See STD DETAILS for valley details.
Wilt: 18.2lbs
Maximum Bot Chord Forces Per Ply (Ibs)
VIEW Ver. 18.02.01A.0205.20 Chords Tens.Comp.
A-C 184 -54
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp.
B - C 166 -150
"WARNING" Please ttMmughly review the -A-1 ROOF TRUSSES('SELLER'), GENERAL TERMS and CONDITONS CUSTOMER ('BUYER') ACNNOVILEDGMENI' Iona.
Verify design paremetom and read notes as this Twu Design Drawing (rDD) and the Anthony T. Tombo III, P.E. Reference Sheet beforeuse. Unlew otherwise stated on theMD, only Mg
r, unle5 oMeN o doMM by a Ge d agreed upon In W11gng by all p Mlea Invelvea. TIIa Tlnse Cosign Englneerle I
iMll Mims are as dented h TPI-1.
RxvMivlimNiM1udn,mnl.mmfmm.krvMlltitMUAXweau,winen rem,IWmNp.1 RWTnuwn-� T.Tn Ill PE.
��TRLLSSIES
Anthony T•Tombo 111, P.E.
# 80083
4451 St. Lucie Blvd.
Fort Pierce. FL 34946
Job Tmss
75775 I MVE
Truss Type
VAL
Oty Ply
1 1 1
04/1V2019
10576
"
Loading Criteria (psp
Wind Criteria
•
TCLL: 30.00
Wind Std: ASCE 7-10
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: C Kzl: NA
Des Ld: 50.00
Mean Height: 15.22 ft
•
NCBCLL: 10.00
TCDL: 5.0 psf
Load Duration: 1.25
BCDL: 5.0 psf
Spacing: 24.0 "
MWFRS Parallel Dist: h/2 to It
C&C Dist a: 3.00 It
Loc. from endwall: not in 9.00
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Purlins
In lieu of stmctural panels or rigid ceiling use pudins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 34 0.00 2.87
Apply pudins to any chords above or below fillers
at 24" OC unless shown otherwise above.
I.. 3"{2'5"4 —�
B
I 2'l0.7
1 2'6"15 'P"'1
Code I Mist; Criteria
CDde:FBC 2017 RES
TPI Sid: 2014
Rep Factors Used: Yes
FT/RT:10(Oy10(10)
Plate Type(s):
WAVE
Wind
Wind loads based on MWFRS with additional C&C member design.
Additional Notes
See STD DETAILS for valley details.
1111.5X4
Defl/CSI Criteria
PP Deflection in toe L/defl L t#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.002 C - -
HORZ(TL): 0.003 C - -
Creep Factor. 2.0
Max TC CSI: 0.115
Max BC CSI: 0.098
Max Web CSI: 0.044
Wgt: 11.2 Ibs
VIEW Ver. 18.02.01A.0205.20
♦ Maximum Reactions (Ibs), or •=PLF
Gravity Non -Gravity
Loc R+ IR- /Rh /Rw /U /RL
C• 103 /- /- /59 /23 /29
Wind reactions based on MWFRS
C Erg Width = 34.4 Min Req = -
Bearing A Is a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
A-B 48 -67
Maximum Bot Chord Forces Per Ply (ibs)
Chords Tens.Comp.
A-C 118 -34
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp.
B-C 102 -95
-WARNING- Please thoroughly review the -A-1 ROOF TRUSSES("SELLER-). GENERAL TERMS and CONDITIONS CUSTOMER("SUYER") ACKNOWLEDGMENT' form.
Vedfy design parameters and read notes on this Truss Design Dmwing(m0) and the Mtholw T. Tomlx, ill. P.E.Refemnoa She.thefomuse.Unlessothery slatedonthe TOD.o nt
p InPiLMW dlhnm m,nt ~RMTnmxe-MMvT. TImM In, P.E.
d
,dAA-1 ROOF
Anthony T•Tombo III, P.E.
# 80083
4451 St. Lucie Blvd.
Fort Pierce. FL 34946
Job Truss
75775 1 MVF
Truss Type
VAL
City Ply
1 11
04/11/2019
10579
Loading Criteria (psq
Mind Criteria
TCLL: 30.00
Wind Sid: ASCE 7-10
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: C Kzl: NA
Des Ld: 50.00
Mean Height: 15.72 ft
NCBCLL: 10.00
TCDL: 5.0 psf
Load Duration: 1.25
BCDL: 5.0 psf
Spacing: 24.0
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.00 It
Loc. from endwall: not in 9.00
GCpI: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP 42
Puffins
In lieu of structural panels or rigid ceiling use pudins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 17 0.00 1.37
Apply pudins to any chords above or below fillers
at 24' OC unless shown otherwise above.
P 3 }-- 11 "4 --{
12
8 �7 B
Code I Misc Criteria
Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes.
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Wind
Wind loads based on MWFRS with additional C&C member design.
Additional Notes
See STD DETAILS for valley details.
-WARNING- Please thoroughly review Me-A-1
adfy design wremeters and read notes on this TThuss DI
r_c
1t4e7
DeflICSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.002 B 999 361
VERT(CL): 0.004 B 999 241
HORZ(LL): 0.001 B - -
HORZ(TL): 0.002 B - -
Creep Factor. 2.0
Max TC CSI: 0.022
Max BC CSI: 0.053
Max Web CSI: 0.000
Wgt: 5.6 Ibs
VIEW Ver. 18.02.01A.0205.20
♦ Maximum Reactions (Ibs), or'=PLF
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
C• 103 1- /- /51 /14 122
Wind reactions based on MWFRS
C Brg Width =16.4 Min Req = -
Bearing A is a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
A-B 0 -24
Maximum Sot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
A-C 44 -13
RAL TERMS and CONDRIONS CUSTOMER ('BUYER') ACMOWLEOGMENP forth.
Tombs ill, P.E. Referenos Sheet before use. Unless olhenviss stated on Me TOD, only All
ally Engineer), Me seal on any TDO represents an acoeptanoe of Me professional engineer
'assumptions. leading mndmmv, suitability and use of this Truss for any Building Is Me
in Me mnMMaf the IRC,Me IBC, oral buiitling cotle and TP41. The approval of the
of Me IRC, Me IBC, IOW building coda antl TPI-1. The approval o1Me TOD antl any geld
MeB tdins redone, eM Cen[ratlu. Mnntea set out in Me TOO and Me oral ions and
M reNTtihG viNru01M wrllm wmh[M bM1 Ra Iln v-MV—T_TmM In PE
'AgTRI SSE5
Anthony T•Tombo III, P.E.
# 80083
4451 St. Lucie Blvd.
Fort Pierce. FL 34946
Job
75775
Truss Truss Type Oty Ply
MVG VAL 11 I1
04/1112019
10582
Loading Criteria (peg
• TCLL: 30.00
TCDL: 10.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 50.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Top chord 2x4 SP #2
Bot chord 2x4 SP 42
Webs 2x4 SP #3
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.25 ft
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: h to 2h
C&C Dist a: 3.00 It
Loc. from endwall: not In 9.00
GCpi: 0.18
Wind Duration: 1.60
Puriins
In lieu of structural panels or rigid Calling use pudins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 58 0.00 4.83
Apply purling to any chords above or below fillers
at 24' OC unless shown otherwise above.
i_ 11"15 'i' 2'7"12 - 1 1-2"3 --
r
12
8 C
12 1111.5X
3.5 p
3X4B
r
2X4(DSR
1
DE
1111.5
4
ii 4'6"6 FA
Code I Misc Criteria
Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT1RT:10(Ou10(10)
Plate Type(s):
WAVE
Wind
Wind loads based on MWFRS with additional C&C member design.
Additional Notes
See STD DETAILS for valley details.
Deb/CSI Criteria
PP Deflection in loc Udell L/#
VERT(LL): 0.045 D 999 361
VERT(CL): 0.076 D 741 241
HORZ(LL):-0.021 C - -
HORZ(TL): 0.036 C - -
Creep Factor. 2.0
Max TC CSI: 0.314
Max BC CSI: 0.310
Max Web CSI: 0.089
Will: 16.8 lbs
VIEW Ver. 18.02.01 A.0205.20
-WARNING" Please thoroughly redew the "A-1 ROOF TRUSSES("SELLER•). GENERAL TERMS and CONDITIONS CUSTOMER
afydesign parameters ead read roles on this Truss Design Dravdng front and Me Mtbony T. Tambo III, P.E. Reference Sheet before use. U
and bracing shall b
(RSCI) published b
v, unless othe .
♦ Maximum Reactions (Ibs), or •=PLF
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
E' 101 /- /- 145 /9 /11
Wind reactions based on MWFRS
E Brg Width = 57.9 Min Req = -
Bearing A is a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 15 -68 B-C 67 -76
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
A-D 123 -15
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp.
C-D 145 -151
ACKNOWLEDGMENT' foml,
ise stated on Me TDD, orly Alp
,e of Me professional engineers
um ii,ft I do —ftmm nM NAARMT—R—An vT Tr in P.E.
,&4 11TA 5EE5
Anthony T•Tombo III, P.E.
480083
4451 St. Lucie Blvd.
Fort Pierce. FL 34946
Job Truss
75775 MVH
Tmss Type City Ply
VAL 1 1
04/112019
10588
Loading Criteria (psq
Wind Criteria
TCLL: 30.00
Wind Sld: ASCE 7-10
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: C Kzt: NA
Des Ld: 50.00
Mean Height: 15.00 it
NCBCLL: 10.00
TCDL: 5.0 psf
Load Duration: 1.25
BCDL: 5.0 psf
Spacing: 24.0 "
MWFRS Parallel Dist: h to 2h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00
GCpI: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP 93
Puriins
In lieu of structural panels or rigid ceiling use purtins
to laterally brace chords as follows:
Chord Spacing(in
cc) Start(fl) End(ft)
BC 75
0.00 8.25
Apply pudins to any chords above or below fillers
at 24" OC unless shown otherwise above.
11.15 6,0"14 1-173 —{
i 93"1
i 5'1"5
Code I Misc Criteria
Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT1RT:10(Ov10(10)
Plate Type(s):
WAVE
Wind
Wind loads based on MWFRS with additional C&C member design.
Right end vertical not exposed to wind pressure.
Additional Notes
See STD DETAILS for valley details.
-WARNING- Plaase Noreughly r mthe-A-1
A aTussI
I on Ne TDD
GENERAL TERMS and
cony T. T.1x, W. P.E. F
In
12
8 P�' D
3'1"12 {
Defl/CSI Criteria
PP Deflection in loc Lldefl L/#
VERT(LL): 0.035 F 999 36(
VERT(CL): 0.059 F 999 24(
HORZ(LL):-0.006 D - -
HORZ(TL): 0.010 D - -
Creep Factor. 2.0
Max TC CSI: 0.396
Max BC CST: 0.247
Max Web CST: 0.099
Wgt: 30.8 Ibs
i
1
♦ Maximum Reactions (Ibs), or •=PLF
G- 101 /- 10 /51 /12 /11 .
Wind reactions based on MWFRS
G Brg Width = 99.0 Min Req = -
Bearing A is a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs) -
Chords Tens.Comp. Chords Tens. Comp.
A-B 45 -156 C-D 42 -59
B-C 15 -65
VIEW Ver. 18.02.OIA.0205.20 1 Maximum got Chord. Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-F 185 -35 F-E 194 -39
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
B-F 332 -377 D-E 95 -76
Ireferencedforgeneralpidance. TPI-tdellnestbemspm,sibilitesanddiLes
3GegreeduDaalnwdtlngbyallpartlaaiavo d. TheTmss Design Eneneerisl
N rmliNNtl wfiM,llMwnXmuamicRknNAIRM TII,RVn�MgMVT. TM 111. PE.
' form.
only All
`"A -I Reef
�1mD55F5
Anthony T•Tombo III, P.E.
# 80083
4451 St. Lucie Blvd.
Fort Pierce. FL 34946
Job Truss Truss Type City Ply 04/11/2019
75775 I MVJ I VAL 11 11 I 1oso3
Loading Criteria fas0
TCLL: 30.00
TCOL: 10.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 50.00
_ NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 •
Top chord 2x4 SP 42
Bot chord 2x4 SP #2
Webs 2x4 SP #3
�I
1'8.3--�
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: It
EXP: C Kzt NA
Mean Height: 15.00 it
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: h to 2h
C&C Dist a: 3.00 it
Loc. from endwall: not in 9.00
GCpi: 0.18
Wind Duration: 1.60
Puriins
In lieu of structural panels or rigid ceiling use pudins
to laterally brace chords as follows:
Chord Spacing(In oc) Stari(ft) End(ft)
BC 75 0.16 10.00
Apply purling, to any chords above or below fillers
at 24. OC unless shown otherwise above.
Code / Misc Criteria
Code: FBC 2017 RES
TPI Bid: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Wind
Wind loads based on MWFRS with additional C&C member design.
Right end vertical not exposed to wind pressure.
Additional Notes
See STD DETAILS for valley details.
"WARNING•• Please thoroughly nwlew One -A-1 ROOF
'wiry design parameters and reed notes on this Truss Design Di
ire
or the Buildim Desianer. in
1'73 -{
12
8 F7
_
10,
DeB/CSI Criteria
PP Deflection in led Udell L/#
VERT(LL): 0.037 D 999 361
VERT(CL): 0.061 D 999 24(
HORZ(LL): 0.013 D - -
HORZ(TL): 0.021 D - -
Creep Factor. 2.0
Max TC CSI: 0.550
Max BC CSI: 0.228
Max Web CSI: 0.120
Wgt: 42.0 Ibs
♦ Maximum Reactions (Ibs), or,=PLF
Gravity Non -Gravity
Loc R+ I R- / Rh / Rw / U / RL
F' 114 /- /- /65 /27 115
Wind reactions based on MWFRS
F Brg Width = 120 Min Req = -
Bearing B is a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 37 0 C-D 20 -81
B-C 48 -192 D-E 77 -88
VIEW Ver. 18.02.01A.0205.20 I Maximum got Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - G 267 -63 G - F 273 -66
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
C - G 374 -452 E - F 154 -150
GENERALTERMS and CONOmONS CUSTOMER ('BUYER-) ACKNOWLEDGMENT' form.
lony T.Tambolll, P.E. Referen�Sheet before u�. Unless olhelwise slated on We TDO. oniv All
M
RWTm-AnIMnvT Tu IILP.E.
A-r ROOF
TRUSSES
Anthony T•Tombo III, P.E.
# 80083
4451 St. Lucie Blvd.
Fort Pierce, FL 34946
Job
75775
Truss
MVK
Truss Type
VAL
City I Ply
104/1112019
10600
Loading Criteria (ps0
TCLL: 30.00
TCDL: 10.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 50.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
IN
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.00 it
Loc. from endwall: not In 9.00
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4-SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3 :W 1 2x6 SP #2:
Puriins
In lieu of structural panels or rigid ceiling use pudins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 - 0.00 10.00
Apply pudins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Code I Misc Criteria
Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0U10(10)
Plate Type(s):
WAVE
Wind
Wind loads based on MWFRS with additional C&C member design.
Right end vertical not exposed to wind pressure.
Additional Notes
See STD DETAILS for valley details.
—WARNING-- Please thoroughly reAe Me -A-1 ROOF TRUSSES
vent' design parameters and read rates on tints Truss Design Dra Mng (To[
connector dates shag be used for Me TDo to be valid. As a Truss Deergn E
819'13 12
.3 _r
-�
12
8 F7
F
De01CSl Criteria
PP Deflection in too L/defl L/#
VERT(LL): 0.041 D 999 361
VERT(CL): 0.067 D 999 241
HORZ(LL):-0.107 D - -
HORZ(TL): 0.125 D - -
Creep Factor. 2.0
Max TC CSI: 0.567
Max BC CSI: 0.308
Max Web CSI: 0.222
Wgt: 49.0 lbs
VIEW Ver. 18.02.01A.0205.20
♦ Maximum Reactions (Ibs), or `=PLF
Gravity Non -Gravity
Loc R+ / R- I Rh / Rw l U I RL
F" 117 /- /- 167 /39 120 y
Wind reactions based on MWFRS
F Brg Width = 120 Min Req = -
Bearing H Is a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.. Chords Tens. Comp.
A-B 45 0 C-D 23 -83
B-C 56 -210 D-E 80 -87
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
H - G 279 -70 G - F 284 -72
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
B-H 317 -368 E-F 142 -146
C - G 420 -460
GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER") ACKNOWLEDGMENT' form.
wry T.Tombolll, P.E. Relerenw Sheet belore use. Unless oMenvisa slated an the TOD, only Alr
. Specialty Engineer), Me seal an any TOD represents an acceptance of rile professional engineeri
b mY Tit l uillwe Mv+Mn mm�iwNnrd A-t RmlTn�cw-AnrMnv T. TruNn OL V E
'0A-t HOOF
�THI155E5
Anthony T•Tombo III, P.E.
# 80083
4451 St. Lucie Blvd.
Fort Pierce, FL 34946
`JANUARY 17, 2017
TYPICAL HIP / KING JACK CONNECTION I STDTL01
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
CORNERSET GENERAL SPECIFICATIONS
MAX LOAD: 55 psf Roof Load, 175 mph, ASCE
7-10, Exp. B, C up to 60' Mean Roof Height
and Exposure D up to 30' Mean Roof Height.
Attach End Jack's
w/ (4) 16d Toe Nails @ TC
& (3) 16d Toe Nails @ BC
0
r
Attach King Jack w/ (3) 16d Toe
,Nails @ TC & 24" Strap w/ (6)
10d x 1.5" ea. end @ BC
ach Corner Jack's
(2) 16d Toe Nails
), TC & BC (Typ)
Attach Corner Jack's
w/ (2) 16d Toe Nails @ TC &
BC (Typ)
Antbwfl L7amho M,G.E
$ 60003
44515L hide Mid..
FWt?7 Ce,: FL' 34946:
FEBRUARY 17, 2017 1 ALTERNATE GABLE END BRACING DETAIL 1 STDTL03
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34945
772d0.9-1010
ALTERNATE DIAGONAL BRACING TO THE BOTTOM CHORD
DIAG. BRACE
AT 1/3 POINTS
IF NEEDED
IT IS THE RESPONSIBILITY OF THE BLDG.
DESIGNER OR THE PROJECT ENGINEER/ARCHITECT
TO DESIGN THE CEILING DIAPHRAGM AND ITS
ATTACHMENT TO THE TRUSSES TO RESIST ALL
OUT OF PLANE LOADS THAT MAY RESULT FROM
THE BRACING OF THE GABLE ENDS.
HORIZONTAL BRACE
(SEE SECTION A -A)
TRUSSSES e
F_ 24' O.C.
2X6 DIAGONAL BRACE SPACED 49'
D.C. ATTACHED TO VERTICAL WITH
(4) - 15d NAILS, AND ATTACHED TO
BLOCKING WITH (5) - IOd COMMONS.
NAIL DIAGONAL BRACE TO
PURLIN WITH TWO 16d NAILS.
2X4 PURLIN FASTENED TO -FOUR
TRUSSES WITH (2) - 16d NAILS
EACH. FASTEN PURLIN TO BLOCKING
W/ (2) - 16d NAILS (MIN.).
' PROVIDE 2X4 BLOCKING BETWEEN
THE TRUSSES SUPPORTING THE
\ BRACE AND THE TWO TRUSSES ON
\ EITHER SIDE AS NOTED. TOENAIL
\ BLOCKING TO TRUSSES WITH (2) -
\ 10d NAILS AT EACH ENO. ATTACH
DIAGONAL BRACE TO BLOCKING WITH
V(5) - 10d COMMON WIRE NAILS.
END WALL
CEILING SHEATHING
BRACING REQUIREMENTS FOR STRUCTURAL GABLE TRUSSES_
STRUCTURAL GABLE TRUSSES MAY BE BRACED AS NOTED:
METHOD 1: ATTACH A MATCHING GABLE TRUSS TO THE INSIDE FACE
OF THE STRUCTURAL GABLE AND FASTEN PER THE
FOLLOWING NAIL SCHEDULE.
METHOD 2: ATTACH 2X_ SCABS TO THE FACE OF EACH VERTICAL
MEMBER ON THE STRUCTURAL GABLE PER THE FOLLOWING
NAILING SCHEDULE. SCABS ARE TO BE OF THE SAME
SIZE, GRADE, AND SPECIES AS THE TRUSS VERTICALS. SCAB ALONG
NAILING SCHEDULE: VERTICAL
- FOR WIND SPEEDS 120 MPH CASCE 7-98, 02, 05), 150 MPH CASCE
7-10) OR LESS, NAIL ALL MEMBERS WITH ONE ROW OF 10d C131'
X 3') NAILS SPACED 6' O.L.
- FOR WIND SPEEDS GREATER 120 MPH (ASCE 7-9B, 02, 05), 150
MPH CASCE 7-10) NAIL ALL MEMBERS WITH TWO ROWS OF 10d
(131'X3') NAILS SPACED 6' O.C. (2X4 STUDS MINIMUM).
MAXIMUM STUD LENGTHS ARE LISTED ON PAGE 1. ALI
BRACING METHODS SHOWN ON PAGE 1 ARE VALID
AND ARE TO BE FASTENED TO THE SCABS OR
VERTICAL STUDS OF THE STANDARD GABLE TRUSS
ON THE INTERIOR SIDE OF THE STRUCTURE.
NOTE: THIS DETAIL IS TO BE USED ONLY FOR
STRUCTURAL GABLES WITH INLAYED
STUDS. TRUSSES WITHOUT INLAYED
STUDS ARE NOT ADDRESSED HERE.
STANDARD GABLE
\S /
oTUD
AN ADEQUATE DIAPHRAGM OR OTHER METHOD OF BRACING
MUST BE PRESENT TO PROVIDE FULL LATERAL SUPPORT OF
THE BOTTOM CHORD TO RESIST ALL OUT OF PLANE LOADS.
THE BRACING SHOWN IN THIS DETAIL IS FOR
VERTICAL/STUDS ONLY.
DULY 17, 2017 I STANDARD PIGGYBACK TRUSS I STDTL04
THIS DETAIL IS APPLICABLE FOR THE FOLLOWING WIND CONDITIONS:
ASCE 7-98, ASCE 7-02, ASCE 7.05, ASCE 7-10 WIND STANDARDS UNDER ALL ENCLOSURE AND EXPOSURE
CONDITIONS AS LONG AS NO UPLIFT EXCEEDS 377 LBS. REFER TO ACTUAL PIGGYBACK TRUSS DESIGN
DRAWING FOR UPLIFTS.
NOTE: THIS DETAIL IS VALID FOR ONE PLY TRUSSES SPACED 24' O.C. OR LESS.
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCER 34946
772-40SA010
PIGGYBACK TRUSS
REFER TO ACTUAL TRUSS DESIGN DRAWING FOR
ADDITIONAL PIGGYBACK TRUSS INFORMATION.
SPACE PURLINS ACCORDING TO THE MAXIMUM
SPACING ON THE TOP CHORD OF THE BASE TRUSS
(SPACING NOT TO EXCEED 24' D.C.) A PURLIN
TO BE LOCATED AT EACH BASE TRUSS JOINT.
ATTACH PIGGYBACK TRUSS TO THE BASE TRUSS WITH 2' X 8"
TEE -LOCK MULTI -USE CONNECTION PLATES SPACED 48'O.C. PLATES
SHALL BE PRESSED INTO THE PIGGYBACK TRUSS AT 48' O.C.
STAGGERED FROM EACH FACE AND NAILED TO THE BASE TRUSS WITH
FOUR (4) 6d (1.5- X 0.099-) NAILS IN EACH PLATE TO ACHIEVE A MAXIMUM
UPLIFT CAPACITY OF 377 LBS. AT EACH 2' X 8" TEE -LOCK MULTI -USE
CONNECTION PLATE (MINIMUM OF 2 PLATES)
ATTACH EACH PURLIN TO THE TOP CHORD OF
THE BASE TRUSS.
(PURLINS AND CONNECTION BY OTHERS)
BASE TRUSS
REFER TO ACTUAL TRUSS DESIGN DRAWING FOR
ADDITIONAL BASE TRUSS INFORMATION.
Anffimy T: Tombo III; P.E.
B 80083.
4451 SL Jude BNd,.
FoR Rlecn; FL 34945
JULY 17, 2017
TRUSSED VALLEY SET DETAIL - SHEATHED I-STDTL0b
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
VALLEYTRUSS
(TYPICAL)
SECURE VALLEY TRUSS
W/ ONE ROW OF 10d
NAILS 6' O.C.
GABLEEND,COMMON
TRUSS, OR GIRDER
TRUSS
DETAIL A
P 12
SEE DETAIL'A'
BELOW (TYP.)
GENERAL SPECIFICATIONS:
1. NAIL SIZE =3°X 0.131'=10d
2. WOOD SCREW = 4.5° WS45 USP OR EQUIVALENT.
3. INSTALL SHEATHING TO TOP CHORD OF BASE TRUSSES.
4. INSTALL VALLEY TRUSSES (24- O.C. MAXIMUM) AND
SECURE TO BASE TRUSSES AS PER DETAIL'A°
5. BRACE VALLEY WEBS IN ACCORDANCE WITH THE
INDIVIDUAL DESIGN DRAWINGS.
6. NAILING DONE PER NOS - 01.
7. VALLEY STUD SPACING NOT TO EXCEED 48° O.C.
BASETRUSSES
VALLEY TRUSS
(TYPICAL)
GABLE END, COMMON
TRUSS, OR GIRDER TRUSS
TRUSS CRITERIA:
WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH
WIND DESIGN PER ASCE 7-10: 170 MPH
MAX MEAN ROOF HEIGHT = 30 FEET
ROOF PITCH = MINIMUM 3112 MAXIMUM 6/12
CATERGORY II BUILDING
EXPOSURE
WIND DURATION OF LOAD INCREASE: 1.60
MAX TOP CHORD TOTAL LOAD = 50 PSF
ATTACH 2X4 CONTINUOUS #2 MAX SPACING = 24' O.C. (BASE AND VALLEY)
SYP TO THE ROOF W/ TWO USP MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES.
WS45 (1/4' X4.5°) WOOD SCREWS
INTO EACH BASE TRUSS.
Anftq V Tomho 1A; d.E.
SM83
4451Stlmle BfPd.
Fart ke`mi FL .349,46,
. JULY 17, 2017 I TRUSSED VALLEY SET DETAIL STDTL06
d GENERAL SPECIFICATIONS:
1. NAIL SIZE=3'X0.131'=10d
�I 2. WOOD SCREW =3' WS3 USP OR EQUIVALENT.
3. INSTALL VALLEY TRUSSES (24- O.C. MAXIMUM) AND SECURE PER DETAIL
.A.
4. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIUAL DESIGN
DRAWINGS.
� 5. BASE TRUSS SHALL BE DESIGNED WITH A PURLIN SPACING EQUIVALENT
TO THE RAKE DIMENSION OF THE VALLEY TRUSS SPACING.
A-1 ROOF TRUSSES 6. NAILING DONE PER NOS -01.
4461 ST. LUCIE BLVD. GABLE END, COMMON 7. VALLEY STUD SPACING NOT TO EXCEED 48' O.C.
FORT PIERCE, FL 34946 TRUSS, OR GIRDER
772409-1010 TRUSS
VALLEY TPRCUSS AL)ly II I I I I I BASE TR11 USSES
(TY
GABLE END, COMMON
TRUSS, OR GIRDER
VALLEY TRUSS TRUSS
P r 72 (TYPICAL)
SEE DETAIL'A'
BELOW (iYP.)
SECURE VALLEY TRUSS
W/ ONE ROW OF 10d
WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05:146 MPH
NAILS 6' O.C.
WIND DESIGN PER ASCE 7-10: 170 MPH
MAX MEAN ROOF HEIGHT = 30 FEET
ROOF PITCH = MINIMUM 3/12 MAXIMUM 6112
CATERGORY It BUILDING
EXPOSURE
WIND DURATION OF LOAD INCREASE: 1.60
ATTACH 2X4 CONTINUOUS 7l2 MAX TOP CHORD TOTAL' LOAD =50 PSF
SYP TO THE ROOF W/ TWO USP MAX SPACING = 24' O.C. (BASE AND VALLEY)
WS3(114-X 3')WOOD SCREWS MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES.
INTO EACH BASE TRUSS.
DETAIL A
(NO SHEATHING) N.T.S.
AnUmny T:T=bo 117; P.E.
9 800&3.
4451St. Lude Blvd.
"plert ,R. 34946
JULY 17, 2017 1 I\VJJI._LJ vr,%L.L.L_ I JL_ I vL_ I rl%1L-
(HIGH WIND VELOCITY)
' STDTLO'7
00
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
ATTAI
WIND DESIGN PER ASCE 7.98, ASCE 7.
WIND DESIGN PERASCE 7-10: 170 MP
MAX MEAN ROOF HEIGHT = 30 FEET
CATERGORY II BUILDING
EXPOSURE B OR C
WIND DURATION OF LOAD INCREASE:
MAX TOP CHORD TOTAL LOAD = 50 PS
MAX SPACING = 24' O.C. (BASE AND V/
SUYYUKI INU I KUbbLb UIKtU I LY UNUtKVALLtY IKU.=b MU61 Ht
DESIGNED WITH A MAXIMUM UNBRACED LENGTH OF 2' -10' ON AFFECTED
TOP CHORDS.
NOTES:
1. SHEATHING APPLIED AFTER INSTALLATION OF VALLEY TRUSSES.
2. THIS DETAIL IS NOT APPLICABLE FOR SPF-S SPECIES LUMBER.
NON -BEVELED
BOTTOM CHORD
FOR BEVELED BOTTOM
CHORD, CLIP MAY BE APPLIED
TO EITHER FACE.
CLIP MAY BE APPLIED
TO THIS FACE UP TO A
MAXIMUM 6112 PITCH
NON -BEVELED
BOTTOM CHORD
CLIP MUST BE APPLIED TO
THIS FACE WHEN PITCH
EXCEEDS 6/12 (MAXIMUM
12/12 PITCH)
Resq tcu!➢e¢:11ixrt�4'I1t1IN:Ib561'mL71&ititMlt(OarG$ItlCCY(CYtl1�itG1',@F4tPtva 1-4LYAaac+t cl�xmairimi8o-8,Cwsiii:7iM�teOotlk2RliKa»4x6Amlu YmGxpbleieRtIDAF¢
Wekwnlmn Mutkkg4mkld.11iklss4wPM=v¢a5 igkeiaQanylOamplt6roaury idmil�✓Ir�nPSPW iaatlN*a6+rry4UmM>pl®ktSm,mkigL u.bSp'tuiagu�,_�isimlm�.'mWtn
An%my T Tombo III, P.E.
virxdm➢1mlbmmktnklepw5Eg4k On2k].m'IeamP19�4 kwdgb ,,YM1uastlkp:.bRWk6! 'mugKiclMl. N WpiNmwsj
900083
'
km.g' nvmmti�Umwma®uwaaq�14q'- Ai�4m=Sid womm
4451 S4 Lude Blvd.
ctmxipi%l4r4'tvlpWip6a51gdl0nF td Bilmtk-opfic>�b{Jik14 EwWT n2in`g6m[ppedgl.Jtq 11tgblldmnwc&Sktc$.
Fort Pierce, R. 34946
� fusLbP�f➢1[LIHJA,v.ld�..T tri.N.➢f. irJaivJW M.®v:L�Mk.,31'aJdJ.�rL y..mwK,i,.6r1]lultc.�:➢ulv.i T..Yw➢t
FEBRUARY 17, 2017 1 STANDARD GABLE END DETAIL I STDTL08
A-1 ROOF TRUSSES
4461 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772409-1010
TYPICAL 2X4 L-BRACE
NAILED TO 2X4 VERTICALS
V/IDd NAILS, G' O.C.
VER
STUI
SECTION B-B
TRUSS GEOMETRY AND CONDITIONS
SHOWN ARE FOR ILLUSTRATION ONLY.
7-- DIAGONAL BRACE 4' - 0' O.C. MAX.
SEE INDIVIDUAL ENGINEERING DRAWINGS
FOR TRUSS DESIGN CRITERIA.
V
Q VARIES TO COMMON TRUSS
* DIAGONAL BRACING ** L - BRACING REFER
REFER TO SECTION A -A TO SECTION B-B
V
24' MAX.
NOTE:
1. MINIMUM GRADE OF #2 MATERIAL IN THE TOP AND BOTTOM CHORDS.
2. CONNECTION BETWEEN BOTTOM CHORD OF GABLE END TRUSS AND WALL TO
BE PROVIDED BY PROJECT ENGINEER OR ARCHITECT.
3. BRACING SHOWN IS FOR INDIVIDUAL TRUSS ONLY. CONSULT BLDG.
ARCHITECT DR ENGINEER FOR TEMPORARY AND PERMANENT BRACING OF ROOF
SYSTEM.
4. L' BRACES SPECIFIED ARE TO BE FULL LENGTH, SPF OR SP #3 OR
BETTER WITH ONE ROW OF IDd NAILS SPACED 6' O.C.
S. DIAGONAL BRACE TO BE APPROXIMATELY 45 DEGREES TO ROOF DIAPHRAGM
AT 4'-0' O.C.
E. CONSTRUCT HORIZONTAL BRACE CONNECTING A 2X6 AND A 2X4 AS SHOWN
WITH 16d NAILS SPACED 6' O.C. HORIZONTAL BRACE TO BE LOCATED AT
THE MIDSPAN OF THE LONGEST GABLE STUD. ATTACH TO VERTICAL GABLE
STUDS WITH (3) IDd NAILS THROUGH 2X4 (REFER TO SECTION A -A)
7 GABLE STUD DEFLECTION MEETS OR EXCEEEOS L/240
VERTICAL
2X6 SP OR SPF
STUDf2X4
#2 DIAGONAL
BRACE
(4) - 16d
NAILS16d
NAILS
SPACED 6' O.C.
(2) IDd NAILS
INTO 2XG2X6
SP OR
SPF #2
2X4 SP OR
SPF #2L
HORIZONTAL
NAILED TD
RTICALS
SECTION A -A
W/(4) - 10d NAILS
PROVIDE 2X4 BLOCKING BETWEEN
THE FIRST TWO TRUSSES AS NOTED.
TOENAIL BLOCKING TO TRUSSES
WITH (2) - 10d NAILS AT EACH END.
ATTACH DIAGONAL BRACE TO
BLOCKING WITH (5) - 10d NAILS
(4) Ed NAILS MINIMUM,
PLYWOOD SHEATHING TO
2X4 STO SPF BLOCK
B. THIS DETAIL DOES NOT APPLY TO STRUCTURAL GABLES. DIAG. BRACE
S. DO NOT USE FLAT BOTTOM CHORD GABLES NEXT TO SCISSOR TYPE AT 1/3 POINTS
TRUSSES. IF NEEDED
10. 10d AND 16d NAILS ARE 0131'X3.0' AND 0131'X3-9' COMMON WIRE NAILS
RESPECTIVELY.
11. SOUTHERN PINE LUMBER DESIGN VALUES ARE THOSE EFFECTIVE 06-01-12
BY SPIB/ALSC.
MINIMUM STUD
SIZE SPECIES
AND GRADE
STUD
SPACING
WITHOUT
BRACE
2X4
L - BRACE
DIAGONAL
BRACE
(2) DIAGONAL
BRACES AT
1/3 POINTS
MAXIMUM STUD LENGTH
2X4SPCSTUD
12'0.C.
3-8-10
5.6-11
6-6-11
11-1.13
2X4SP#31SIUD
16'0.C.
33-10
4-9.12
6&11
9-10-15
2X4SP#31STUD
24'0.C.
2-8-6
3-11-3
54-12
8-1-2
2X4 SP M2
12'O.C.
3-10-15
5-6-11
6&11
11-8.14
2X45P112
16'0.C.
3{r11
4-9-12
6-6-11
10-8-0
2x45Pz2
24'O.C.
3-1.4
3-11-3
6.2-9
9-3-13
DIAGONAL BRACES OVER 6' - 3' REQUIRE A 2X4 T-BRACE ATTACHED TO ONE
EDGE. DIAGONAL BRACES OVER 12' - 6' REQUIRE 2X4 I -BRACES ATTACHED TO
BOTH EDGES. FASTEN T AND I BRACES TO NARROW EDGE OF DIAGONAL BRACE
WITH 10d NAILS 6' Q.C., WITH 3' MINIMUM ENO DISTANCE. BRACE MUST COVER
907 OF DIAGONAL LENGTH. T OR I BRACES MUST BE 2X4 SPF #2 OR SP #2.
rom
ROOF
SHEATHING
(2) - 10d
NAILS
TRUSSES @ 24' D.C.
2X6 DIAGONAL BRACE
SPACED 48' D.C. ATTACHED
TO VERTICAL WITH (4) -
16d NAILS, AND ATTACHED
TO BLOCKING WITH (5) -
10d NAILS.
HORIZONTAL BRACE
(SEE SECTION A -A)
END WALL
IGHT= 30 FEET
STUD DESIGN IS BASED ON COMPONENTS AND CLADDING.
INCREASE: 1.60 CONNECTION OF BRACING IS BASED ON MWFRS.
FEBRUARY 17, 2017
WITH 2X BRACE ONLY
STDTL09
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 3494
772-409-1010
VOTES:
T-BRACING / I -BRACING TO BE USED WHEN CONTINUOUS LATERAL BRACING
;S IMPRACTICAL. T-BRACE / I -BRACE MUST COVER SOX OF WEB LENGTH.
PHIS DETAIL NOT TO BE USED TO CONVERT T-BRACE / I -BRACE WEBS TC
:ONTINUOUS LATERAL BRACED WEBS.
NAILING PATTERN
T-BRACE SIZE
NAIL SIZE
NAIL SPACING
2X4 OR 2X6 OR 2XB
10d
6' O.C.
NOTE NAIL ALONG ENTIRE LENGTH OF T-BRACE / 1-BRACE (ON
TWO-PLY TRUSSES NAIL TO BOTH PLIES)
BRACE
SIZE FOR ONE -PLY
TRUSS
SPECIFIED CONTINUOUS ROWS OF
LATERAL BRACING
WEB SIZE
1
2
2X3 OR 2X4
2X4 T-BRACE
2X4 I -BRACE
2X6
2X6 T-BRACE
2X6 I -BRACE
2XB
2X8 T-BRACE
2XB I -BRACE
BRACE
SIZE FOR. TWO-PLY
TRUSS
SPECIFIED CONTINUOUS ROWS
LATERAL BRACING
OF
WEB SIZE
1
2
2X3 OR 2X4
2X4 T-BRACE
2X4 I -BRACE
2XB
2XB T-BRACE
2X6 I -BRACE
2X8
2X8 T-BRACE
2X8 I -BRACE
T-BRACE / I -BRACE MUST BE SAME SPECIES
AND GRADE (OR BETTER) AS WEB MEMBER.
NAILS
WEB
NAILS
I -BRACE
1( NAILS
WEB
T-BRACE
SECTION DETAILS
FEBRUARY17,2017 1 LATERAL BRACING RECOMMENDATIONS I STDTI-10
f0 MINIMIZE VIBRATION COMMON TO ALL SHALLOW FRAMING SYSTEMS,
2XB 'STRONGBACK' IS RECOMMENDED, LOCATED EVERY 8 TO 10 FEET
ALONG A FLOOR TRUSS.
�NOTE 1: 2X6 STRONGBACK ORIENTED VERTICALLY MAY BE POSITIONED DIRECTLY UNDER THE
TOP CHORD OR DIRECTLY ABOVE THE BOTTOM CHORD, SECURELY FASTENED TO THE TRUSS USING ANY
A-1 ROOF TRUSSES OF THE METHODS ILLUSTRATED BELOW.
4451 STD LUCIE BLVD,
FORT PIERCE, FL 34946 NOTE 2: STRONGBACK BRACING ALSO SATISFIES THE LATERAL BRACING REQUIREMENTS FOR THE
772-409-1010 BOTTOM CHORD OF THE TRUSS WHEN IT IS PLACED ON TOP OF THE BOTTOM CHORD, IS CONTINUOUS
FROM ENO TO ENO, CONNECTED WITH A METHOD OTHER THAN METAL FRAMING ANCHOR, AND PROPERLY
CONNECTED, BY OTHERS, AT THE ENDS.
INSERT WOOD SCREW THROUGH
OUTSIDE FACE OF CHORD INTO
EDGE OF STRONGBACK (00 NOT
USE METAL FRAMING -I ATTACH TO VERTICAL ATTACH TO VERTICAL USE DRYWALL TYPE SCREWS)
ANCHOR TO ATTACH WEB WITH 1, -IDd C SCAB WITH (3) - lOd
TO TOP CHORD \NAILS WITH
( X 3') NAILS WITH
( X 3'). ATTACH TO VERTICAL
WEB WITH (3) - 10d
NAILS (0131' X 3')
BLOCKING BEHIND THE VERTICAL
WEB IS RECOMMENDED WHILE
NAILING THE STRONGBACK
USE METAL FRAMING J Z ATTACH TO VERTICAL
ANCHOR TO ATTACH WEB WITH -(3) - 10d
TO BOTTOM CHORD NAILS (0131' X 3')
ATTACH 2X4 VERTICAL
TO FACE OF TRUSS.
FASTEN TO TOP AND
BOTTOM CHORD WITH
(2) - IDd NAILS (0131'
X 3') IN EACH CHORD
ATTACH TO VERTICAL
SCAB WITH (3) - 10d
NAILS (0131' X 3')
TRUSS 2XG 4' - 0' WALL
STRONGBACK � (TYPICAL SPLICE) � (BY OTHERS)
ATTACH TO CHORD
WITH (2) #12 X 3'
WOOD SCREWS
(0.216' DIA1
INSERT SCREW THROUGH
OUTSIDE FACE OF CHORD INTO
EDGE OF STRONGBACK (00 NOT
USE DRYWALL TYPE SCREWS)
THE STRONGBACKS SHALL BE SECURED AT THEIR ENDS TO AN ADEQUATE SUPPORT,
DESIGNED BY OTHERS. IF SPLICING IS NECESSARY, USE A 4' - 0' LONG SCAB
CENTERED ON THE SPLICE AND JOINED WITH (12) - IDd NAILS (0131' X 3')
EQUALLY SPACED.
ALTERNATE METHOD OF SPLICING:
OVERLAP STRONGBACK MEMBERS A MINIMUM OF 4' - 0' AND FASTEN WITH (12) -
10d NAILS (0431' X 3') STAGGERED AND EQUALLY SPACED (TO BE USED ONLY
WHEN STRONGBACK IS NOT ALIGNED WITH A VERTICAL).
BLOCKING
(BY OTHERS)
FEBRUARY17,2017 1 LATERAL -TOE -NAIL DETAIL _ 5TDTL11
AA ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772409-1010
NOTES:
1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 45• WITH THE MEMBER
AND MUST HAVE FULL WOOD SUPPORT (NAIL MUST BE DRIVEN
THROUGH AND EXIT AT THE BACK CORNER OF THE MEMBER END AS
SHOWN).
2. THE ENO DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL
BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.
3. _ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO
SPECIES FOR MEMBERS OF DIFFERENT SPECIES.
TOE -NAIL SINGLE SHEAR VALUES
PER NOS 2001 (LB/NAIL)
CIA
SP
OF
HF
SPF
SPF-S
.131
88.0
80.6
69.9
68.4
59.7
o
.135
93.5
85.6
74.2
72.6
63.4
J
in
.162
108.8
99.6
86.4
84.5
73.8
ri
.128
74.2
67.9
58.9
57.6
50.3
c�
p
.131
75.9
69.5
60.3
59.0
51.1
J
n
.148
81.4
74.5
64.6
63.2
52.5
ci
VALUES SHOWN ARE CAPACITY PER TOE -NAIL.
APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED.
EXAMPLE:
(3) - 16d NAILS (0162' CIA. X 35') WITH SPF SPECIES BOTTOM CHORD
FOR LOAD DURATION INCREASE OF 115:
3 (NAILS) X 845 (LB/NAIL) X 115 IDOL) = 2915 LB 'MAXIMUM CAPACITY
ANGLE MAY
VARY FROM
30° TO 60'
45.00'
ANGLE MAY
VARY FROM
3V TO 60'
THIS DETAIL IS ONLY APPLICABLE TO
THE THREE END DETAILS SHOWN BELOW.
SIDE VIEW
(20) 2 NAILS
NEAR SIDE
NEAR SIDE
SIDE VIEW
(2X4) 3 NAILS
77NEAR SIDE
. NEAR SIDE
NEAR SIDE
45.00'
SIDE VIEW
(2X3) 2 NAILS
NEAR SIDE
NEAR SIDE
NEAR SIDE
NEAR SIDE
ANGLE MAY
VARY FROM
30° TO 60•
45.000
l -
FEBRUARY 17, 2017 1 UPLIFT TOE -NAIL DETAIL I STDTL12
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409,1010
THIS DETAIL SHALL BE USED FOR A CONNECTION
RESISITING UPLIFT FORCES ONLY. BUILDING DESIGNER
IS RESPONSIBLE FOR LOADS IN OTHER DIRECTIONS.
TDE-NAIL WITHDRAWAL VALUES
PER NOS 2005 (LB/NAIL)
DIA.
SP
OF
HF
SPF
SPF-S
L7
.131
59
46
32
30
20
z
-1
.135
60
48
33
30
20
Uri
.162
72
58
39
37
25
J
F
0.128
54
42
28
27
19
LD
Z
Z
-1
.131
55
43
29
28
19
LU
.148
62
48
34
31
21
J
L0
J
N
Q
M
,
Z
.120
51
39
27
26
17
C0
Z
.128
49
38
26
25
17
O
.131
51
39
27
26
17
M
.148
57
44
31
28
20
NOTES:
1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 30' WITH THE MEMBER AND STARTED 1/3 THE LENGTH OF THE NAIL FROM THE
MEMBER ENO AS SHOWN.
2. THE ENO DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.
3. ALLOWABLE VALUE SHALL BE BASED ON THE SPECIE WITH LOWER NAIL CAPACITY BETWEEN THE TWO MEMBERS IN THE CONNECTION.
VALUES SHOWN ARE CAPACITY PER TOE -NAIL.
APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED.
EXAMPLE:
(3) - 16d NAILS (0162' DIA. X 33') WITH SPF SPECIES TOP PLATE
FOR WIND DOL OF 133:
3 (NAILS) X 37 (LB/NAIL) X 133 IDOL FOR WIND) = 14B LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND
FOR WIND DOL OF 1.60:
3 (NAILS) X 37 (LB/NAIL) X 1.60 IDOL FOR WIND) = 177 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WINO
IF THE UPLIFT REACTION SPECIFIED ON THE TRUSS DESIGN DRAWING EXCEEDS 147 LBS (177 LBS) BUILDING
DESIGNER IS RESPONSIBLE TO SPECIFY A DIFFERENT CONNECTION.
*00 USE (3) TOE -NAILS ON 2X4 BEARING WALL
*to USE (4) TOE -NAILS ON 2X6 BEARING WALL
NEAR SIDE
FAR S.
1E
TOP PLATE
OF WALL
VIEWS SHOWN ARE FOR
ILLUSTRATION PURPOSES ONLY
IL
NAIL
NAIL
SIDE VIEW END VIEW
FEBRUARY 5, 2016
TYP W NAILER ATTACHMENT
STDTL13
R
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
1.0x4
2x2 NAILER ATTACHMENT
GENERAL SPECIFICATIONS
MAX LOAD: 55 psf Roof Load, 170 mph, ASCE
7-10, 29'-0" Mean Height, Exp. B, C or D.
a
*April 11, 2016
TYPICAL ALTERNATE BRACING DETAIL
FO EXTERIOR FLAT GIRDER TRUSS
STDTL14
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
(4) 12d
TRUSS 2411 O.C.
UPLIFT CONNECTION
(SEE ROOF TRUSS)
12
VARIES
(4) 12d
MAX 3011 (21-611)
2x6 #2 SP (Both Faces)
2411 O.C.
EXTERIOR FLAT `-- SIMPSON H5
GIRDER
<apPRbO 1016N
A,M=y T. T.RI, P.E
s 8Wde
Ai51 SL Woe
Fa[ 94 Plerce, R M3C9i6
FEBRUARY 17, 2017 STANDARD REPAIR DETAIL FOR BROKEN CHORDS, WEBS, AND STDTL15 !
DAMAGED OR MISSING CHORD SPLICE PLATES
C
TOTAL NUMBER MAXIMUM FORCE (CBS) 15
OF NAILS EACH
SIDE OF BREAK
X
(INCHES)
% LOAD DURATION
SIP
OF
SPF
HF
w FEBRUARY 17, 2017 1 SCAB APPLIED OVERHANGS I STDTL16
n
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772409-1010
TRUSS CRITERIA:
LOADING: 40-10-D-10
DURATION FACTOR: 115
SPACING: 24' O.C.
TOP CHORD: 2X4 OR 2X6
PITCH: 4/12 - 12/12
HEEL HEIGHT: STANDARD HEEL UP TO 12' ENERGY HEEL
ENO BEARING CONDITION
NOTES:
1. ATTACH 2X-SCAB (MINIMUM #2 GRADE SPF, HF, SP, OF) TO ONE FACE OF TRUSS
WITH TWO ROWS OF IOd COMMON WIRE NAILS (148' DIA. X 3') SPACED 6' O.C.
2., THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH
AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.
3. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO
AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES.
2X SC
NOTE: TRUSS BUILT WITHOUT AN OVERHANG. THIS DETAIL IS NOT TO BE USED
WHEN OVERHANG HAS BEEN BROKEN OFF.
IMPORTANT
THIS DETAIL TO BE USED ONLY WITH TRUSSES (SPANS LESS THAN 4D') SPACED 24,
O.C. MAXIMUM AND HAVING PITCHES BETWEEN 4/12 AND 12/12 AND TOTAL TOP CHORD
LOADS NOT EXCEEDING 50 PSF.
TRUSSES NOT FITTING THESE CRITERIA SHOULD BE EXAMINED INDIVIDUALLY.