Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-21117 FILE COPY FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performandg(M BY Lucie Project Name: WYNNE THE STERLING Builder Name: WYNNE DEVELOPMENT Street: THE STERLING Permit Office: ST. LUCIE COUNTY City, State,'Zip: FT. PIE , FL, Permit Number: Owner: S �� Jurisdiction: Design Location: FL, Fort fierce County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1442.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft' b. Frame - Wood, Adjacent R=11.0 192.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling Types (1474.0 soft.) Insulation Area a. Under Attic (Vented) R=30.0 1474.00 ft' 6. Conditioned floor area above grade (W) 1474 b. N/A R= ft' Conditioned floor area below grade 0 c. N/A R= ft' 11. Ducts R ft' 7. Windows(141.3 sqft.) Description Area a. Sup: Attic, Rat: Attic, AH: Attic 6 300 a. U-Factor: Sgl, U=0.63 101.25 ft' SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 40.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 34.8 SEER:15.00 c. U-Factor. N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft. a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.239 14. Hot water systems 8. Floor Types (1473.5 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft' b. Conservation features EF: 0.970 b. WA R= ft' None c. WA R= fP 15. Credits Pstat Glass/Floor Area: 0.096 Total Proposed Modified Loads: 48.34 PASS Total Baseline Loads: 48.53 1 hereby certify that the plans and specifications covered by Review of the plans and STq?A this calculation are in compliance with the Florida Energy specifications covered by this 0448E Code. calculation indicates compliance with the Florida Energy Code. PREP D r. Before construction is completed O DATE: - this building will be inspected for compliance with Section 553.908 �� O P y ° e v I hereby certify that this building, as designed, is in compliance Florida Statutes. !,), with the Fldrida Energy Code. C'Op we OWNER/AGET' t BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 4/4/2018 10:16 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 PROJECT Title: WYNNE THE STERLING Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1474 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180 Street: THE STERLING Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1474 11792 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 329 2632 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M. BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 329 ft2 -_ 0 1 0 2Slab-On-Grade Edge Insulatio WIC 1 ft 0 63 ft2 ____ 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH a ft 0 56 ft2 ____ 0 1 0 4 Slab -Oh -Grade Edge Insulatio KITCHEN 1 ft 0 192 ft2 -_ 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft2 — 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft2 ___ 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft2 0 1 0 414/2018 10:16 AM ' EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet ,88Iab-On-Grade Edge Insulatio LAUNDRY E ft 0 42 ft' 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft' 0 1 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1553 ft' 246 fN Light 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1474 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 329 ft' 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft' 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft' 0.1 Wood .4 Under Attic (Vented) KITCHEN 30 Blown 192 ft' 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft' 0.1 Wood .6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft' 0.1 Wood _ 7 Under Attic (Vented) ENTRY 30 Blown 55 ft' 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft' 0.1 Wood 9 Urider Attic (Vented) GREAT/DINING 30 Blown 488 ft' 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 1 NE=>SW Exterior Concrete Block - Ext Ins®EDROOM 4.1 10 0 8 0 80.0 ft' 0 0 0.6 0 2 SW=>NE Exterior Concrete Block - Ext Ins®EDROOM 4.1 28 0 8 0 224.0 ft' 0 0 0.6 0 3 NW ->SE Exterior Concrete Block - Ext Ins®EDROOM 4.1 14 0 8 0 112.0 ft' 0 0 0.6 0 4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft' 0 0 0.6 0 5 NE=>SW Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.6 0 6 NE=>SW Exterior Concrete Block - Ext InfiffDROOM 2 4.1 16 0 8 0 128.0 ft' 0 0 0.6 0 _ 7 SE=>NW Exterior Concrete Block - Ext InfiffDROOM 2 4.1 10 0 8 0 80.0 ft' 0 0 0.6 0 8 S4>N Exterior Concrete Block - Ext InEB&DROOM 2 4.1 4 3 8 0 34.0 ft' 0 0 0.6 0 9 SW=>NE Exterior Concrete Block - Ext InfiEDROOM 2 4.1 2 0 8 0 16.0 ft' 0 0 0.6 0 10 SE=>NW Exterior Concrete Black - Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft' 0 0 0.6 0 11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft' 0 0 0.6 0 12 SW=>NE Exterior Concrete Block - Ext InsalAUNDRY 4.1 6 0 8 0 48.0 ft' 0 0 0.6 0 13 NE=>SW Exterior Concrete Block - Ext InsGREAT/DINI 4.1 26 0 8 0 208.0 ft' 0 0 0.6 0 _14 NW=>SE Exterior Concrete Block- Ext Ins REAT/DINI 4.1 20 0 8 0 160.0 ft' 0 0 0.6 0 15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft' 0.23 0.6 0 4/4/2018 10:16 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 DOORS . # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft2 WINDOWS Orientation shown is the entered orientation => chan ed to Worst Case. _ / Wall V # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3. SE=>NW 7 Metal 4 NE=>SW13 Metal 5. NW=>SE14 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes 0.63 0.25 N 32.9 ft2 1 It 0 in 1 ft 4 in 0.63 0.25 N 6.9 ft2 1 It 0 in 1 ft 4 in 0.63 0.25 N 24.0 ft2 6 It 0 in 1 It 4 in 0.63 0.25 N 37.5 ft2 1 It 0 in 1 It 4 in 0.65 0.21 N 40.0 ft2 8 It 0 in 1 It 4 in Drapes/blinds None None None Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft2 315 ft2 24 It 8 It 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1375.7 75.53 142.04 .2598 7 HEATING SYSTEM .# System Type Subtype Efficiency Capacity Block Ducts .1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.86 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 4/4/2018 10:16 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM R4Q5-2017 DUCTS _ / -- Supply — — Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic ' 6 300 ft' Attic 75 ft' Default Leakage Attic (Default) (Default) 7 1 TEMPERATURES Programablre'Thermosta[[t: Y Ceilling Fans:Cool Heating :l Jan (X� Feb Mar [ j [ ] AApr [ ] May [[[ ]j Jun [ ] Jul [[ [X� Aug [[ ]] [X] Sep ] L J_OOcctt [D(]� Nov Dec rr Venting I 1 Jan l [I III Feb X X Mar [X) [[) [- Jun tXl EX] 1 Jul [[ Aug [[ ]) Sep lxl [X] Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Coaling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WO) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4/4/2018 1b:16 AM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE•THE STERLING Builder Name: WYNNE DEVELOPMENT Street: THE STERLING Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire snr nkler cover plates and walls or ceilings a. in addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 4/4/2018 10:16 AM EnergyGaugeO USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. THE STERLING, FT. PIERCE, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- Ext Insul, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R=11.0 192.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft' 5. Is this a worst case? Yes 10. Ceiling Types Insulation Area a. Under Attic (Vented) R=30.0 1474.00 ft2 6. Conditioned floor area (ft2) 1474 b. N/A R= ft' 7. Windows" Description Area c. N/A R= ft2 a. U-Factor. Sgl, U=0.63 101.25 ft2 11. Duds a. Sup: Attic, Ret: Attic, AH: Attic R ft2 6 300 SHGC: SHGC=0.25 b. U-Factor. Sgl, U=0.65 40.00 ft2 SHGC: SHGC=0.21 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 34.8 SEER:15.00 SHGC: d. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 3.832 ft. a. Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average SHGC: 0.239 8. Floor Types Insulation Area 14. Hot water systems a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft a. Electric Cap: 40 gallons b. N/A R= ft= EF: 0.97 c. N/A R= ft2 b. Conservation features None 15. Credits Pstat I certify thaf this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. r, Builder Signature:-� Date: Address of New Home:. Z City/FL Zip 'Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. "Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/4/2918 10:16 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 +P- wrightsofte Project Summary Enure House QUICK.CALCS, INC. 317 Sr. LUCIE M. FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 For. WYNNE DEVELOPMENT THE CA`RRLTON�299, FT. PIERCE, FL Notes: Weather. Winter Design Conditions Outside db Inside db Design TD 42 OF 70. OF 28 OF Heating Summary Structure 18188 Btuh Ducts e Central vent (0 cfm) 0 5654 Btuh (none) Humidification0 Btuh Piping 0 Btuh Equipment load 23842 Btuh Infiltration Method Construction quality Fireplaces Area. (ft2) Volume (ftJ Air changeslhour Equiv. AVF (cfm) Fort Pierce, FL, US Simplified Average 0 He 1474 Co 1474 12227 12227 0.45 0.23 92 47 Heating. Equipment. Summary Make Carrier Trade CARRIERAIR CONDITIONING Model 25HBC536A*030 AHRI ref 7914585 Efficiency Heating Input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat Capacity balance point = 33 OF Backup: 8.5 HSPF 34600 Btuh @ 47°F 0 1160 cfm 0.049 cfm/Bl 0.50 in H2O Input = 7 kW, Output = 23009 Btuh, 100 AFUE Job: Date: By: SCANNED BY St. Lucie County Summer Design Conditions Outside db 90 OF Inside db 75 OF. Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 17877 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh (none). Blower 0 Btuh Use manufacturers data n Rate/swingg multipplier Equipmentsensibleload 0.95 25093 Btuh Latent Cooling Equipment Load Sizing Structure 2958 Btuh Ducts 2319 Btuh Central vet (0 cfm) 0 Btuh (none): Equipment latent load 5277 Btuh Equipment total load 30370' Btuh Req. total capacity at 0.70 SHR 3.0 ton Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A*030 Coil FX4DN((B,F)037 AHRI ref 7914585 12.0 EER, 15 SEER i cooling 24360 Btuh ooling 10440 Btuh Olin g 34800 Btuh drfla 1160 cfm factor 0.044 cfm/Btuh -ensure 0.50 in H2O isible heat ratio 0.83 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. '& * wrightSof , RightSuite@ Universal 2017 17.0.14 RSU08101. 2017 Apr-10 1 :14: 1 ...Wrightsoft WACIMNNE-THE GRAND CARLTON-299.tup Calc=MJ8 FrontDoorfaces: N Page f� wrightsoft• Right-J@ Worksheet Job: Entire House Dace: QUICK CALCS, INC. 9y- 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 F= 772-466-6796 Ertwl: OUICKCALCS AOLCOM 1 Room name Entire House BEDROOM 2 Eprsed wall 156.2 It 52.0 ft 3 Room height 8.3 ft d 8.0 ft heaticool 4 Room dimensions 1.0 x 329.0 it 5 Room area 1473.5 ft2 329.0 ft2 Ty Construction U-value Or HTM Area Load Am Load number I (BtuNfl2•°F) (StUh/ft2) or perimeter (ft) (Btuh). or pe. aer (ft) (Btuh) Heat Cool Gross WPIS Heat Cool Gmss WP/S - Heat Cool 6 Uy '. 4G:.lAclbn 13A4ccs,,.. :. • 0143 ne.. 400 i 2,55 •479 442, .: 1768, -1124 . ] �. 80 80 320 `,: ,204 - - ;1.270. no ':.- 3556 "..70.43 - 36 :• 0 .�: 1344: :2662 _-.,0 . 0:.. 0 - :-0 W 13AAccs 0.143 se 400 255 128 83 331 210 0 0 0 0 LGD 1Aclan 1.270 se 35.56 34.77 24 48 848 829 0 0 0 0 11 11DO 0.390 se 10.92 11.31 22 22 236 244 0 0 0 0 W-.-"-13AAcis.^. '.6.143':-s - 4:00 265 .34 -34. :... 136 86 0- ..0: .0 ., ._. W L--G 13AAccs 0.143 sw 4.00 2.55 360 353 1414 899 224 224 897 570 1Actan 1.270 sw 35.56 42.91 7 it 247 298 0 0 0 .0 - 13A-0ocs .0143 rnv 400 255 290:" 217 857 =551 112 79 318 '202 tAclan 1270 nw - 3556 .-45.24 33 - 0 � 1162 1478 ::33 0 '... 1162 4478. " 4PS2an 0770 t@Y -21.56 ., 27:54 41 : 0.::. :880'.. 0.' 0:'..'•0- P 12C-0sw 0.091 - 255 1.28 192 192 489 _1124-0 246 0 0 0 0 C `.-`°.:16&Mmd 9.032 :0.90 232 ". 1474 1474' ..1320 ..-3419 .329:.; - 329 295 763 F 22A-01 0.989 - 27.69 0.00 1474 156 4325 0 329 ' 52 1440 0 6 c)AED excursion 784 680 Envelope loss/gain 15366 13954 4432 3897 12 a) Infiltration 2822 773 909 249 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 5 1160 2 460 Applianceslother 2000 0 Subtotal (lines 6 to 13) 18188 17977 5341 4606 Less adend load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18188 17877 5341 46M 15 Duct loads 31% 48% 5654 853 6 31% 48% 1660 2199 Total room load I I 23842 26413 7001 6805 Air required(crm) 11. 1160 341 299 Calculations approved byACCA to meet all requirements of Manual J Oth Ed ,A # wrightsofY 2017-Apr-1017:14:53 RGRAN OeO UnIverRLTOsa 99.ru 17Cato RSU08104 . Page 1 ...Wdghtsoft HVAC1WYMVE-THE GRAND CARLTON-299.mp Caic=MJB Front Door faces: N + wrightsoft° Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOLCOM M. BATH sed wall 0 ft 8.0 ftm TmWIC height 8.0 ft heallcool 8.0 ft heaticool m dimensions 7.0 x 9.0 ft 7.0 x 8.0 ft m area 63.0 fto 56.0 W TY Constmctim U-value Or HTM Area Load Am (1115 Load number (BtulVft-F) (Btul") or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heal Cool Gross WKS Heat - Cool Gross -WP/S Heat Cod - 6 L—G`'1Aclomr. 13A4ocs.w.. +0143 ne - 4.00 �3556 255 ,0 -0 I0" --0 0 0 0 0 1270 ne%s_` ,:70:43 .. 0 .' 0 �. ` ; 0, 0' .:0-" 0 ,.'0 h/ 1344= 0.143 se 4 W 255 0 0 0 0 0 0 0 0 �L--..OD 1A-clom 1270 se 35.56 34.77 0 0 0 0 0 0 0 0 11 11D0 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 W-'.•;. A3A466s:, ,.. .. ... " '0143``a �,, ,4.00 `2155' - :0 --0' 0= 0,.•. 0' '-;0 0-.-. `.">'0 W 13A4acs 0143 sw 4.00 2.55 0 0 0 0 64 .". 57 228 145 `-G 1Ac1= 1270 sw 3556 4291 0 0 0 0 7 5 247 298 13Adacs.0143 mv. 400 s255 0 . 0 '.:.- 0 .. 0 0 -, 0 "' 0 :; -.0 -`1Ac1om ' -." "1270 rrw, 3556 45:24 ,0 0 '- 0 ...0 .-0- 0:;' 0 0 4A6S2onc -0770,nw�,-� 21.56 27s54 �0 � 0 _ 0 -.' '0 -• �0' 0� -0 P ' 1200sw 0.091 - 255 1.28 0 0 0 0 0 0 0 0 G:: -16M130md' am - .0.90 232 63 63 . 56 - 146 66 -:66 . 60 130 F 22A-t0l - 0.989 - 27.69 0.00 63 0 0 0 56 8 222 0 6 c)Ai D mmioo -2 - y� Emlope loss/gain 56 145 747 798 12 a) Infiltration 0 0 140 38 b) Roomventialion 0 0 0 0 13 Intemai gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (fines 6 to 13) 56 145 807 836 Less eMemal load 0 0 0 0 Less transfer 0 0 0 0 RedistriNiipn - 0 0 0 0 14 sotal ubt 56 145 &w 836 15 Dud loads 31% 48% 18 69 31% 48% 276 399 Total room load I 1 1 74 214 1162 1235 Airrequired(ofm) 4 9 57 - 64 Calculations approved byACCA to meet all requirements of Manual J 8th Ed A wrighksofv RightSuite® Universe] 2017 17.0.14 RSU08101' 2017-ApF1017:14:53 ...Wrightsoft HVAC%VJYNNE-THE GRAND CARLTCN499.rup Cale = MJ8 Front Door faces: N Page 2 wrightsoft' Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone; 7724666799 Fax 77246"796 Email: OUICKCALCS@AOL.COM '1 Room name WrCHEN WH i 0 ft 5.0 ft 3 Room eh Igh 8.0 ft heaticool 8.0 ft heaticool 4 Room dimensions 1.0 x 1920 It 9.0 x 5.0 ft 5 Room area 192.0 ft- 45.0 ft' Ty Consbuctim U-value Or HiM Ama Am number (Btuh/ft;°F) (Btul✓ft') or perimeter (ft) (Btuh) or perimfetter (ft) (&tuh) Hear - Cool Gross -WP/S Heat Cool Gross WP/S Heat - Cool 6 W , ' 13A4oes:i ., .- 0.143 .,_ ne 4.00 ..,Z55 - 0 -. 0 `' 0 . 0 , ' ' 40 40 '_ ' 16D ;,.1D2 G- 1Aciam ^: • 1.270 'mi. '35.5690.43 0 " '0,'0 .: 0 - _ "0 0= 0 :. `�0 13A4ccs 0.143 se 4.00 255 0 0 0 0 0 0 0 0 tAclom 1.270 se 35.56 34.77 0 0 0 0 0 0 0 0 11 11DO '_. 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 W "..- .13A4ccs,. .. ,. 0.143 . S... ; .4.00 - :.255 - 0 :. 0 > _0 �. 0 0 0 - ---0 0 W 13A4ccs 0.143 sw 4.00 255 0 0 0 0 0 0 0 _. 0 1Aclom 1270 sw 3556 42.91 0 0 0 0 0 0 0 0 _ 13A-0ars .. '- .0143 rrvi -. -' 400 ':255 0 ` 0 - - 0 0 ":0 0 0 1Ac1om ` ;-1270 nw;� 3556 '45:24 0 --• 0 = o r , 0 •• ;0 0..- . o .'0 ':=o " - ..%0.770 .,nw 2L56 - -'27.54 -. 0 s .0 .: - , 0 - . D - -;;0 _ .0 P 12C-0sw 0.091 - 255 1.28 64 64 163 82 0 0 0 0 C<_ -% 16430md 0.032:-:✓, - ,0.90 2.32::. 192 192.:. ._ :172. A45 `. :-45 .. 'i45:. 'r10 �. „103 F 22Atpl 0.989 - 27.69 0.00 192 0 0 0 45 5 . 138 0 6 c)AED e=nslon -27 -2 Envelope Icss/gain 335 501 339 2D4 12 a) hlfiltration 0 0 87 24 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 D Appliances/other 2000 0 &Notal Qlnes 6 to 13) 335 2501 426 228 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 14 Sutrtotat 335 2501 426 ,0 228 15 Duct loads 31% 48% 104 1194 31% 48% 133 109 Total room load 421 3162 527 316 Air required(cfm) Calculations approved byACCA to meet all requirements of Manual J 8th Ed ,ft wrightsofv RlghtSufle® Universal 201717.0.14 RSU08101 2017-Apr-1017.14:63 _,Wdghtsoft HVACIWYNNE-THE GRAND CARLTON-299.rup Calc = MJ8 Front Door faces: N Page 3 wrightsoft Right-M Worksheet Job: Entire House Date: QUICK CAS, INC. By: LL 317 ST. LUCIE LM, FT. PIERCE, FL 34946 Phone: 77246"799 Fax 772-466-6796 Email: OUICKCALCS@AOL.COM 1 Room name 13mR60M2 ENTRY 2 Fiposed wall 32.2 ft 7.0 ft 3 Room height 8.0 If heat/cool 8.0 If heat/coot 4 Room dimensions 1.0 x 203.5 ft 1.0 x 55.0 ft 5 Room area 203.5 ft2 55.0 it - Ty Construction U-value Or HTM Area Load Am (M Load number (Btuh/ftMF) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gloss WP/S - Heat Cool Gross WP/S: Heat Cool 8 la"ocs r' • 0143 ne 400 255 128 r 128 • - 513 326 " 0 0 , 0 : •.:. 0 1Ac1om*.. - .. 1.270 1.270 no - .. 35.56 70:43 -. 0 0:•- 0 � 0` 0.:.. 0 „ ,., 0 "'=.0 VN�C 73A-4acs se 4.00 255 60 58 220 143 48 28 106 67 `D 1Aclom 1.270 se 35.56 34.77 24 24 848 829 0 0 0 0 11 11DO 0.390 as 10.92 11.31 0 0 0 0 22 22 236 244 _ ;13A4acs, ' .. - 164 1. - 86 _ ` - • ;8 - r2 1�/ 1--f' 0.143 sw 4.00 265 16 16 8 32 0 1Acian 1 z7o sw 35 ss a2.s1 0 o a 0 0 0 0 0 13A4009 ,0143 nw -- 4,00 .':255 -. 0 `• 0 0 - .0 ..a - . 0 �-.. 0 -';:0 1Aa1om `. - :1270 nw --3556 45.24 :0 `: 0 '- 0.. `0 ,0, 0:= 0 :;-'0 '4A5-tom -_ " :0770 mv. •2156 27:54 0'. 0 0 .. '0 ...0 0.! 0 `?0 P 12C-0sw 0.091 - 255 1.28 0 0 0 0 72 72 183 92 'C 16AMnd 0.032 - 0.90 232 204 204 182 472 55 -55 49 .. 128 F 22MPI 0.969 - Zr.69 0.00 204 32 891 0 55 7 194 0 6 c)AEDexcursion -24 -6 Erwope lass/gain 2859 1873 Boo 545 12 a) Mitration 564 154 122 34 b) Room wrdilaton 0 0 0 .0 13 Intemal gains: Occupants @ 23D 1 230 0 0 Appliances/other 0 0 Subtotal pines 6 to 13) 3422 2257 922 679 Less erdemal load 0 0 0 0 Less hensfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3422 2257 922 579 15 Duct loads 31% 48% 1WA 1078 31% 48% 287 Z76 Total room load 4486 3335 1209 855 Alr required(dim) 218 146 59 38 Calculations approved by CA to meet all requirements of Manual J 8th Ed. l- weKghttsofL- - _ - 2017-Apr-1017.14:53 .�GZA RGRANDC Universal 9.w 17Cale RSU08101 Page4 ...WdghtsoR HVAC\WYNNE-THE GRAND CARLTON-299.mp CaIc=MJB From Door races: N Wrightsoft• Right-M Worksheet Job' Entire House Date: QUICK CALCS, INC. BY. 317 ST. LUCIE LN, FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: OUICKCALCSOAOL.COM 1 Room name LAUNDRY GREAT/DINNG - wall height 6.0 ft 46.0 ft 3 RRoom 8.0 It heaUcool 8.9 ft heat/cool 4 Room dimereions .. 70 x 60 ft 1.0 x 488.0 ft 5 Room area 420 ft' 488.0 ft' TY Construction U-wiue Or HTM Area (ft� Load Area (ftq Load number (Btu (Btuh/ft9 or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool. ..Gross - N/PIS - -Heat-- Cod Gross- N/P/S Heat- -- Coop 6 t41� t3A4acs -.. '0143 ne� -_- 400 : '255 . 0- 0 - 0 ..- 0 231 ' 194 ..° 77.5 ' ;'493 i-G ]Ao1om `:.1270 'he. . 3556 .70.43 .,'0 0 _ 0 :-' 0 38 �:. 0 :` 1394 " 2662 % 13A-0ocs 0143 se 400 255 0 0 0 0 0 0 0 ' 0 F—i' �D 1Acicm 1270 se 35.56 34.77 0 0 0 0 0 0 0 0 11 11DO 0.390 $a 10.92 11.31 0 0 0 0 0 0 0 0 Wr. " 13(t-0ocs _-, .� - "0143 S, ., 4.00 -:fZ55 01_ 0-; 0' . -.0. - 0 =0 o =: d_ t. W 13A4acs 0143 sw 4.00 255 48 48 192. 122 0 0 - 0 0 l--f` 1Actom 1270 sw 3556 42.91 0 0 0 0 0 0 0 0 13A4oes .0143 nw - 400' 255 0 ­0 0 :0 178 137 --;; 549 �34§ 1Ac1an '=1 270 nw :.35.56 - v 45:24 .0 :r 0 0 ; 0 , O :d 0 , r 0 =. 0 ..=0.770 . my --.21.56 27.54 0 : '.0 - . 0 :0 -. .41 0: 880 '11?A 46I, y0l 0.00 42I 166I 488 46 12741132 0 6 c)AED etxlasion 1 1-3 -56 Envelope lass/gain 539 2W 5259 6704 12 a) Infiltration 105 29 895 245 b) RoomveMilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal Qines 6 to 13) 644 317 6154 6409 Less eAemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 644 317 6154 6409 15 Duct loads' 31% 48% 200 151 31% 480% 1913 3D60 Total roam load 844 468 gp� gmAir required(cfm) 41 21 393 416 Calculations approved byACCA to meet all requirements of Manual J 8th Ed A Wrighitsofit- Ri9htSuite& Universal 2017 17.0.14 RSUD8101 2017-Apr-1017:14:63 ...Wrightsoft IiVADtWYNNE-THE GRAND CARLTON-299.mp Colo = MJB Front Door faces: N Page 5 - wrightsoft Duct System Summary Dab Endre House By: QUICK CALCS, INC. 317 ST. LUCIE LN, FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUCKCALCS@AOLCOM . For. WYNNE DEVELOPMENT . _. THE CARLTON 299, FT. PIERCE, FL Heating Cooling Extemal static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available' Static pressure 0.50 in H2O 0.50 in H2O Supply / return available pressure 0.250 / 0.250: in H2O 0.250 / 0.250 in H2O Lowest friction rate 0.284 in1100ft 0.284 iN100ft Actual air flow 1160 cfm 1160 cfm Total effective length (fEL) 176 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (In) Duct Matt Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 559 27 15 0.376 4.0 OxO VIFx 18.1 115.0 st1 BEDROOM 2 h 4486 218 146 0.374 6.0 OxO VIFx 18.6 115.0 st1 BEDROOM -A h 3501- 170 149 0.297- 6.0 OxO VIFx 33.1 135.0 st2 BEDROOM$ h 3501- 170 149 6.284 6.0 0x0 VIFx 41.1 135.0 91:2 ENTRY h 1209 59 38 0.510 4.0 OxO VIFx 3.0 95.0 GREATIDINING c 4735 196208 0.318 7.0 0x0 VIFx 22.4 135.0 st2 GREAT/DINING$ c 4735 196 208 0.307 7.0 OxO VIFx 28.1 135.0 st2 KITCHEN- C 3695 21 162 0.375 .7.0 0x0 VIFx 18.3 115.0 st1 LAUNDRY h 844 41 21 0.366 6.0 0x0 VIFx 21.6 115.0 sill M.BATH h 1162 57 54 0.366 4.0 Ox0 VIFx 21.6 115.0 st1 wlc c 214 4 9 0.310 4.0 OxO VIFx 26.3 135.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (In) (In) Material Trunk st2 Peak AVF 737 724 0.284 689 14.0 0 x 0 VinlFlx SH st1 PeakAVF 1101 1122 0.284 804 16.0 0 x 0 VinlFlx t wrl htsaft° 2017-Apr-m 17: i4.64 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 7 ... WrightS02 WAC%WYNNE-THE GRAND CARLTON-299.rup Cale = MJ8 From Door faces: N Name Grille Size (in) Htg (cfm) Cig (cfm) TEL (ft) Design FIR I Veloc (fpm) I Diam (in) H x W (in) StudlJcist Opening (in) Duct Mail Trunk rb1 Ox0. 1160 1160 0 0 0 0 Ox 0 1 VIFx wrl htsoft° 2017-Apr-1017:14:54 � 9 RightSude® Universal 17.0.14 RSU08101 ...Wrighlsoft WAMWYME-THE GRAND CARLTON-299.rup Cale =MJB Front Door faces: N Page 2