Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY EFFICIENCY CODE
FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE MAJESTIC Builder Name: U Street: THE MAJESTIC �� _l'�- .3 Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL,�- \\ ram. WYNNE 'ks\� Permit Number: SCANNEDOwner: DEV. C Jurisdiction: BY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ).St. Lucie r 1. New construction or existing New (From Plans) 9. Wall Types (1512.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1128.00 ft2 b. Frame - Wood, Exterior R=11.0 384.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling Types (1608.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1608.00 ft2 6. Conditioned floor area above grade (ft2) 1608 b. N/A R= ft' Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(141.9 sqft.) Description Area a. Sup: Attic, Rat: Attic, AH: Attic 6 275 a. U-Factor: Sgl, U=0.54 101.94 ft2 SHGC: SHGC=0.25 b. U-Factor. Sgl, U=0.55 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtulhr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.254 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems 8. Floor Types (1608.0 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1608.00 ft2 b. Conservation features EF: 0.970 b. N/A R= ft2 None c. N/A R= ft' 15. Credits Pstat Glass/Floor Area: 0.088 Total Proposed Modified Loads: 50.22 PASS Total Baseline Loads: 50.28 1 hereby certify that the plans and specifications covered by Review of the plans and tftE Srq?F this calculation are in compliance with the Florida Energy specifications covered by this Of Code. 2 calculation indicates compliance with the Florida Energy Code. N Off, PREPARE Before construction is completed DATE: 1, this building will be inspected for compliance with Section 553.908 O y h 1� I hereby certify that this building, as designed, is in compliance Florida Statutes. !,) with the Florida Energy Code. COD WETR� OWNER/AG Ep1I: BUILDING OFFICIAL: DATE: 1 t DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 6/27/2018 2:54 PM EnergyGauge® USA Section R405.4.1 Co pliaai E COPY Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: - WYNNE THE MAJESTIC Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1608 Lot # Owner Name: WYNNE DEV. Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: Rotate Angle: 225 Street: THE MAJESTIC Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1608 12864 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MASTER BEDROO 238 1904 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M. BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes 7 DINING/GREAT R 589 4712 No 0 1 Yes Yes Yes 8 KITCHEN 228 1824 Yes 0 1 Yes Yes Yes 9 BATH 2 50 400 No 0 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 82 656 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BEDRO 38 ft 0 238 ft2 _- 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft2 ___ 0 1 0 3 Slab -On -Grade Edge Insulatio MASTER BATH 8 ft 0 56 ft2 0 1 0 4 Slab -On -Grade Edge Insulatio M. BATH 7 ft 0 61 ft2 ___ 0 1 0 5 Slab -On -Grade Edge Insulatio tAUDRY 1 ft 0 36 ft2 ____ 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 12 ft 0 180 ft2 0 1 0 6/27/2018 2:54 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 7 Slab -On -Grade Edge Insulatio DINING/GREAT 50 ft 0 589 ft' ___ 0 1 0 8 Slab -On -Grade Edge Insulatio KITCHEN 12 ft 0 228 ft' ___ 0 1 0 9 Slab -On -Grade Edge Insulatio BATH 2 5 It 0 50 ft' _- 0 1 0 10Slab-On-Grade Edge Insulatio HALL 1 It 0 25 ft' _- 0 1 0 11Slab-On-Grade Edge Insulatio FOYER 9 ft 0 82 ft' _- 0 1 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 1695 ft' 0 ft' Light 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1608 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 238 ft' 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft' 0.1 Wood 3 Under Attic (Vented) MASTER BATH 30 Blown 56 ft' 0.1 Wood 4 Under Attic (Vented) M. BATH 30 Blown 61 ft' 0.1 Wood 5 Under Attic (Vented) LAUDRY 30 Blown 36 ft' 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 180 ft' 0.1 Wood 7 Under Attic (Vented) DINING/GREAT 30 Blown 589 ft' 0.1 Wood 8 Under Attic (Vented) KITCHEN 30 Blown 228 ft' 0.1 Wood 9 Under Attic (Vented) BATH 2 30 Blown 50 ft' 0.1 Wood 10 Under Attic (Vented) HALL 30 Blown 25 ft' 0.1 Wood 11 Under Attic (Vented) FOYER 30 Blown 82 ft' 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below a 1 NE=>W Exterior Concrete Block - Ext IndNASTER BE 4.1 17 0 8 0 136.0 ft' 0 0 0.5 0 2 SW=>E Exterior Concrete Block - Ext InSMASTER BE 4.1 7 0 8 0 56.0 ft' 0 0 0.5 0 3 NW=>S Exterior Concrete Block - Ext In9MASTER BE 4.1 14 0 8 0 112.0 ft' 0 0 0.5 0 4 NE=>W Exterior Concrete Block - Ext IndNIASTER BA 4.1 8 0 8 0 64.0 ft' 0 0 0.5 0 5 NE=>W Exterior Concrete Block - Ext InsuM. BATH 4.1 7 0 8 0 56.0 ft' 0 0 0.5 0 6 NE=>W Exterior Concrete Block - Ext IndMDROOM 2 4.1 12 0 8 0 96.0 ft' 0 0 0.5 0 7 SW=>E Exterior Concrete Block - Ext IndWNING/GRE 4.1 30 0 8 0 240.0 ft' 0 0 0.5 0 -8 NW=>S Exterior Concrete Block - Ext InDINING/GRE 4.1 20 0 8 0 160.0 ft' 0 0 0.5 0 6/27/2018 2:54 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacdnt Cavity Width Height Sheathing Framing Solar Below - Space _ 9 SW=>E Exterior Concrete Block - Ext InsuKITCHEN 4.1 12 0 8 0 96.0 ft' 0 0 0.5 0 _ 10 NE=>W Exterior Concrete Block - Ext Insul BATH 2 4.1 5 0 8 0 40.0 ft' 0 0 0.5 0 _ 11 SE=>N Exterior Concrete Block - Ext Insul FOYER 4.1 8 0 8 0 64.0 ft' 0 0 0.5 0 _ 12 SW=>E Exterior Concrete Block - Ext Insul FOYER 4.1 1 0 8 0 8.0 ft' 0 0 0.5 0 _ 13 N=>SW Exterior Frame -Wood MASTER BE 11 26 8 208.0 ft' 0.23 0.5 0 14 E=>NW Exterior Frame -Wood MASTER BE 11 11 8 88.0 ft' 0.23 0.5 0 15 W=>SE Exterior Frame - Wood MASTER BE 11 11 8 88.0 ft' 0.23 0.5 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>N Insulated FOYER None .28 3 3 6 8 21.7 ft' WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>S 3 Metal Low-E Single Yes 0.54 0.25 N 32.9 ft' 1 it 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 NE=>W 5 Metal Low-E Single Yes 0.54 0.25 N 6.9 ft' 1 It 0 in 1 ft 4 in None None 3 NE=>W 6 Metal Low-E Single Yes 0.54 0.25 N 16.4 ft' 1 ft 0 in 1 ft 4 in None None 4 SW=>E 7 Metal Low-E Single Yes 0.54 0.25 N 20.6 ft' 1 ft 0 in 1 ft 4 in None None 5 SW=>E 7 Metal Low-E Single Yes 0.54 0.25 N 25.1 ft' 1 it 0 in 1 it 4 in None None 6 NW=>S 8 Metal Low-E Single Yes 0.55 0.25 N 40.0 ft' 9 it 0 in 1 it 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 1040 ft' 1040 ft' 48 it 8 it 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000366 1500.8 82.39 154.95 .2578 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 6/27/2018 2:54 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Duds 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr dm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS _ / -- Supply — — Return -- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 275 ft' Attic 85 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Fans: Cr anrX'I ng € Jan HF VentiNov Feb [Cooling Mar Aprrreiling Apr May f ] �ay,xl Jun [X] Jul [X� [ ] Aug f ri Sep [ j IrX'I L J OctNov Dec [X] [ Jun [ 1 Jul [)Aug [ Sep lXl [X] Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Coaling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. _ 0 ft' 0 ft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ft' ft 0.3 WIC Default(8 lbs/sq.ft. ft' ft 0.3 MASTER BATH Default(8 lbs/sq.ft. ft' ft 0.3 M. BATH Default(8 lbs/sq.ft. ft' ft 0.3 LAUDRY Default(8 lbs/sq.ft. ft' ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft' ft 0.3 DINING/GREAT R Default(8 lbs/sq.ft. ft' ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft' ft 0.3 BATH 2 Default(81bs/sq.ft. ft' ft 0.3 HALL Default(8 lbs/sq.ft. ft' ft 0.3 FOYER Name: Test Rater E&M-8-R&O mamallim-rom.- - - a Rating Compant: Test Rater Date: 6/27/2018 2:54 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE MAJESTIC Builder Name: Street: THE MAJESTIC Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y Owner: WYNNE DEV. Jurisdiction: w Design Location: FL, Fort Pierce _ c� COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ed ceiling/soffit y the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac Bs. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind pining and wiring Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electricallphone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids bab=an lire zn 13k!gr cover plates al2d wall or jogs a. In addition, inspection of log walls shall be m accordance with the provisions of ICC-400. 6/27/2018 2:54 PM EnergyGauge® USA FBC 6lh Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEERICOP 6. Conditioned floor area (sq. ft.) 6. 1608 d) Room Unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.543 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 14. Heating system: Capacity 34.8 c) Area 7c. 141.9 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.97 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. 11.0 e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 0 Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit 0 Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. (� Builder Signature: Date: Address of New Home: THE MAJESTIC City/FL Zip: FT. PIERCE. FL 6/27/2018 2:54:38 PM EnergyGaugeO USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 WrlIItSOft° 9 Project Summary Job: Date: Enure House By: QUICK CALCS, INC. 317 Sr. LUCIE Lk, FT. PIERCE, FL 34946 Phone: 772-46"799 Fax 772-466-6796 Email: QUCKCALCS a@AOLCOM For. WYNNE DEV. THE,MAJESTIC, FT. PIERCE, FL Notes: Weather. Fort Pierce, FL, US Winter Design_ Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 17339 Btuh Ducts 5899 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 23239 Btuh Infiltration Method Simplified Construction quality Average Fireplaces ' 0 Area Heatingg Coolingg (fta) 1608 1608 Volume (fta) 13924 13924 Air changesthour 0.38 0.20 Equiv. AVF (cfm) 88 46 Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A'030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat Capacity balance point = 32 OF 8.5 HSPF 34600 Btuh @ 47"F 27 °F 1160 cfm 0:050 cfm/Btuh 0.50 in H2O Backup: Input = 7 kW, Output = 23009 Btuh, 100 AFUE �C St �4o QyNFO C�4�y Summer Design Conditions Outside db 90 OF Inside,db . 75 of Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 grub Sensible Cooling Equipment Load Sizing Structure 17020 Btuh Ducts 8920 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Ratetswing multiplier Equipmenf load 0.95 sensible 24W Btuh Latent Cooling Equipment Load Sizing Structure 3339 Btuh Ducts 2433 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 5772 Btuh Equipment total load 30415 Btuh Req, total capacity at 0.70 SHR 2.9 ton Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536MO30 Coil FX4DN((B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh . Actual airflow 1160. cfm Airfbwfactor 0.045 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.82 Calculations approved byACCA to meet all requirements of Manuel J 8th Ed + wrilghtsbft• RightSuite® Universal 2017 17.0.1 4 RSU08101 2017-Apr-11 0 :2 : 4 m ...k CalcslDocuentslWYME-MAJESTIC MODEL-1608.mp Cale =MJ8 Front Door faces: N g wrightsoft Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LM, FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Emil: OUICKCALCSCdAOLCOM 1 Room name Entire House MASTER BEDROOM 3 Rya edwall 9 141.0 ft 46.0 ft 4 Room dimensions 8.7 ft d 8.0 It heaUcool 5 Room area 1608.0 ft- 294.0 ft-1.0 x 294.0 It Ty Construction U-value Or HTM Area Load Asea (M Load number (BtuNRioF) (Btuwft') or perimeter (ft) (Btuh) o perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gress WP/S Heat Cool 6 Vy , ^ 13Miocs .. 9143 ..0770-ne, z.ne 4.00 .2;55 454 ! 408 1634 1039 - 56 r - 224 - `143 r-, gAS2om ;' 2156' 36.90 21 - 0 ;', ggfi --' .7fi4 ..0.. .56 .0 GG VjI 4AS20m,.' 13A4ocs 0770 ne, =- 31.56 '. 36.90 26 ;i .0 543 .-. `930. .'0 ::. .0: 0 -; •si0 11 L---D 11DO 0.143 se 4.00 255 64 41 165 105 0 0 0 p VIy-G 13A;46, 0390 0143 se sw. ID92 4 00 11.31 255 23 392 23 - 369 248 ' 1476 267 0 0 ' 200 0 0 1Ac1an , 1.270 sw ...3558 • 4291 7 . - 5 . .. 247 ..939 , ; 298 -200 :0 ; - - 0 801 :: 0 ,-: 509 "-D _i-G tAolom r ,.1270 sw. -. 35.56 �' S¢:02.. 16_' - ._ 8.:-581- �,883 _ 0> p:.. 0 13A-0acs 0.143 w 4.00 Z65 308 235 939 597 _ ,' 112 70 318 202 IL-�Ga 1Aclom 1.270 nw 35.56 45.24 33 0 1162 1478 33 0 1162 1478 ` :'.'120-05w 4A5-2omd " 0.770 nw 21.56 36.90 41 0 880 1505 0 0 0 0 P . 0.091 .;. - 2.55 .. -128 +. ` .'376 '376 '958 . :0 •0 °.. •` 0 C 16A30md 0.0ffi - 0.90 232 1608 1608 1441 ,482=" 3731 294 .. ...0 294 263 682 F : ;22A-tpl .-' - - 0.989 27.69 0.00 1608 141 ' ;3905 '. 0 294 48 1274 .....: _.0 6 c)AED ersursion 1638 729 Envelope loss/gain 14626 14645 4042 3743 12 a) infiltration b) Room ventilation 2714 765 ffi0 231 0 0 0 0 13 Internal gains: Occupants @ 230 7 1610 1 Appliances/other 230 p 0 Swatat fees 6 to 13) 17339 17020 4862 42D5 Less eternal load 0 0 Less transfer 0 0 0 0 Redrstdtxrtion 0 0 0 0 14 15 Subtotal Dud loads 17339 17020 0 4862 0 4205 34% 62% 5899 8920 34-A 52% 1654 2204 Total room bad Air required (dm) 23239 25941 6518 6908 1160 1160 325 287 Calculations approved byACCA to meet all requirements of Manual J 8th Ed r wrsghtsaft- ,.��p RlghtSufle® Universal 2017 77.0.14 RSU08101 2017- �11 09:28:14 - ...k C8l0slDocurrents%WYNNE-MAJESTIC MODEL-1608.mp Colo =MJ8 Front Door faces: N Page 1 + wrightsoft Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LILL, FT. PIERCE, FL 34946 Phone: 772-466.6799 Fevc 772-466-6796 Email: OUICKCALCS@AOLCOM 1 2 Room name Slimed wall WIC M. BATH 3 Room height 0 It 8.0 It heallcool 7.0 ft 8.0 It ool heat/o 4 5 Room dimensions Room area 7.0 x 9.0 It - x 61.0 ft 63.0 ft2 61.0 ft21.0 Ty Construction U-value Or HTM Area (ft2) Load Area number (Btul✓ftz-F) (BtuNft2) or perimeter (ft) (Ruh) a pedmeter (ft) (Bt�uh) Heat Cool Gmss NOS Heat Cool Gross WP/S Heat Cool 6 V 13AAccs 4Ab2cm ..0143 ne . 4.00 `2156 255 0 0 -.. 0 , 0 0 0 0 �."0 4A5-2am -0770 i0770 ne ne �: 21.56. °'_36.90 '0 , 0 0 •`. 0 -.. 0 .0 . ".0:- ' 0. 0 r,, map W 11DO 0143 se 400 -36.90 255 -0 _ 0 0 0 0 0 _;0 0 0 0 11 I-D 11D0 0390 as 1092 11.31 0 0 0 0 0 0 0 0 0 0 0 4�/ �C 13A4ocs yiAcicm .-0143 :] z7a sw sw 400 -.. _3556 265 4291 0. 0 0 0 0 ' 0 56 - 49 196 ' > .125 tAaio. `. m. Az70 sw. 3556 .'5402 0'. .:. .0 0 + 0 > o --0 Z 0' : 5 0:, i.. 247 U 298 13A-4= 0143-nw 400 255 0 0 0 0 0 0 0 ;1-•0 I---G �L---GG A 1.270 my 35.66 45.24 0 0 0 C o 0 0 o 4A5-2=d Szom. 0.770 nw 21.56 36.90 0 0 0 0 0 0 a a P;12C-0MV,-- - :0.091 -.,:. . -. '2.55 ; .. ,3:28 `.; . A "0... 0:. � �- 0 -0 r.;' �.. i0p C 16MOrnd 0.032 0.90 232 63 63 56 146 61 61 55 142 0.989 ^,7_ ` -27.69 DOW .. 63 .... g p �, .. _.p. ... 61 :. 7,: 194 ': ii0 6 c)AID elxursion 0 234 Envelope loss/gain 56 ia5 692 798 12 a) Infiltration 0 0 120 35 b) Room ventlation 0 0 0 0 13 Interval gains: Occupants @ 230 0 0 0 Appliances/other p p D Subtotal Qines 6 to 13) 56 146 816 833 Less e#emal load 0 0 0 0 Less transfer 0 0 0 Redistdbution 0 0 0 74 15 Subtotal Duct loads `19 177 0 0 34% 52% 19 77 34% 52% 278 278 437 437 Total room load Alrmquired(cfm) 76 223 1094 1269 4 70 155 67 ter' Calculations approved bYACCA to meet all requirements of Manual J 8th Ed ..,ftFp- wrighYsoR- RlghlSufte® Un1wrsal 201717.0.14 RSUOS10t 2017-Apr-11 09.28:14 ...k Calcs1Doeuments1WYM4E4ViAJESnC MODEL-1608.mp Cale =MJ8 Front Door faces: N Page wrightsoft Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-46"799 Fa c 772-46"796 Email: OUICKCALCS@AOL.COM 1 Room name LAUDRY BEDROOM 2 =ed wall O ft 120 ft 3 Room helght 8.0 If heat/cool 8.0 ft heaUcad 4 Room dimensions 6.0 x 6.0 It 16.0 x 120 ft 5 Room arm 36.0 ft- 180.0 ft' Ty Construction U-value Or HTM Area Load number (BtWWF) (Btu)Jft-) orperimeter (ft) (Btuh) orsperimeter (ft) (Btuh) Heat Cool Gross WPIS Heat Cool Gross WPIS Heat Cool 6 13A4ocsl.-, -0143 ne 4.00 255 0 0 " 0', 0 '0 0- 0 '0 4AS2an; .`;0770 ne -=21,56 :,. ".36.90"b' 0 0 ... 0 `.0' :i0 ' 0 „`:0 :4A5-2an,.-. - .--0.770 ne.; -' 21.66 :. ,36.90 .,. -.0 •, •.0 0. 7 ": ,0 ,. - 0: :0-. 0 • _ V�/ LD 13A400s 0.143 se 4.00 255 0 0 0 0 0 0 0 0 11 11DO 0390 se 1092 11.31 0 0 0 0 0 0 0 0 V�/ 13A-0ocs• 0143 sw 400 255 •'•'4291 • 0 0 0 0 88 ' 80 : 310 ' , 203 yl-C�1Ac1om `. ;' .1270 sw `=d3556 <-' . 0.�. 0.: ;: 0--" ' ''0. .. ., .0` 0 0 a0 1Ac1om. `1.270 sw 35.56 . • 54.02 .0 p 0 �. 0 18 - - 8 SO ^ ' •.-.;g83 13A-0ocs 0.143 nw 4.00 255 0 0 0 0 0 0 0 0 1Ao1om 1.270 my 35.56 4524 0 0 0 0 0 0 0 0 '--G 4A5-20md 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 P _` ,12C-0sW , . :. �0.091 ;�.- � ,.255 A28 .'0 . •. - 01 . � 0 % � 0 -' , 104 �.. -:404 - 265 ,� .. 7133 C 16A-3Umd .- O.IXi2 - 0.90 232 36 36 - 32 84 180 180 161 418 IF - ',i 224401 F _ . .. 0.989 - ._ ,27.69 6 0.00 .._ ; .. 36 , :' .. 0 .. 0 .� 0 . . 180 12 • 332 1 ,, :. zr:0 z 6 c)AED excursion 0 507 Envelope lossfgain 32 84 1659 2143 12 a) Infiltration 0 0 214 60 b) Room ventilation 0 0 0 0 13 Internal gam: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal Oines 6 to 13) 32 84 1873 2204 Less odemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 15 6 15 14 Subtotal 38 98 1878 2218 15 Dud loads 34% 52% 13 51 34% 52% &M 1162 Total room load 51 149 2517 3381 Air requited(dm) 3 7 126 151 �,.1� Calculations approved byACCA to meet all requirements of -Manual J 8th Ed. A& 'Tk- wr7ghts ft- RlghtSuiteO Unkerse1201717.0.14 RSU08101 2017-Apr-11 09:28:14 ...k CeIcslDocuments\WYMNE-MAJESTIC MODEL-1606.mp Cato = MJB Front Door faces: N Page 3 wrightsoft, Right-JO Worksheet Job: Entire House Date: sy. QUICK CALLS, INC. 317 ST. LUCIE LN.. FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name DININGIGREAT ROOM WCHEN Sgwed wall 50.0 If 12.0 ft 3 9M 9.8 It heWcool 8.0 it heat/cool 4 Room dimensions 1.0 x 689.0 ft 19.0 x 12-0 ft 5 Room area 589.0 fP 228.0 ft' Ty Construction U-value Or HTM Area Load Am number I (BluWWF) (BtuMft� or Perimeter (ft) (Btuh) wa pedmeter (ft) (Bt�uh) Heat Cool Gross NIP/B Heat Cool Gross WP/S Heat Cool 6 ':13A4ocs -.. 0143 -.'0770 ne 400 : ".•2.65 294 ' 248 _ 993 .632 96, 96, 384 244 ,. 4A5.2m -._ ne ' <.2156 '. �.36.90 21 -' 0! - 446 , I'764' 0;- '0--- 0 "'0 4ASZom ;. •:. 0.770 , ne - 21.56 36.90 25 ;::" 0 _ 543 " - 930 0 .0 ' 0 .: '„ o Vd L-D 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 6 11 11D0 0390 se 1092 11.31 0 0 0 0 0 0 0 0 13A-000s .0143 sw '-400 -255 0' 0 0 ;0 0. 0 0 ;'0 1Actom .1270 sw .,'3556 42.91 0-,- 0. 0 ,. 0 "0' 0: - 10 '; 0 1270 sw "3556 .: .54:oz . 0 `• 0 .- - 0 _ -0 .0' 0., .0 "r;0 �1 I-G 13AAccs 0.143 nw 400 255- 196 155 621 395 0 0 0 0 1Aclom 1.270 my 3556 45.24 0 0 0 0 0 0 0 0 l--G 4A5-2=d 0.770 my 21.56 36.90 41 0 880 1505 0 0 0 0 R- :_-12C-0siv;:=:. - -0.091':- 255 A28-,` -0 0' -0=. `0 -..104I: ;.104: 265 C 16A-30md 0.032 - 0.90 232 689 589 528 :' 1366 228 - 221 204 529 F:- - ..22AiP1.1• . - = 0.989 : - 27.89 Q00 -589 60 1385 i - 0. 228 .. ' 12 + 332 '.: _ 0 6 c)AED excursion 168 0 Envelope losslgain 5396 5760 1186 907 12 a) trx6Hration 1092 308 214 60 b) Rcomvemilation 0 0 0 0 13 internal gains: Occupants @ 230 4 920 2 460 Applianceslother 0 0 Subtotal Dines 6 to 13) 6488 6988 1400 1427 Less external! load 0 01 0 0 Less transfer 0 0 0 - 0 Redistribution 6 15 0 0 14 SUMotal 6494 7002 1400 1427 15 Duct loads 34% 52% 2209 3670 34-A 52% 476 748 Total room load 8703 10672 1876 2175 Airrequired(Mm) 434 477 94 97 Calculations approved byACCA to meet all requirements of Manual J Bth Ed .48& -Fp- wrllghttsoft- RlghtSufte® Universal 201717.0.14 RSUD8101 2017-Apr-11 09:28:14 ...k Calca\Docurnents\WYNNE-MAJESTIC MODEL-1608.rup Cale =MJ8 Front Door faces: N Page + wrightsoft, Right-J® Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE I.R. FT. PIERCE, FL 34946 Phone: 772-4665799 Fax 772-466-6796 Email: QUCKCALCS@AOLCOM 1 Room name BATH 2 HALL 2 E;qaosed wall 5.0 It 0 It 3 4 Room height 8.0 IthwVcoci 8.0 It hest/cool Room dimensions 10.0 x 5.0 It 5.0 x 5.0 It 5 Room area 50.0 ft2 25.0 ft2 Ty Construction U-Value Or HTM Area Load Am f number. (Btuh/ft"F) (Btuwm or perimeter (ft) (Btuh) w perimeter (n) (dun) Heat Cool Grass WKS Heat Cool Gross WP/S Heat Cool .13AAocs. - :. 0.143 ne' 4.00 - 2.55 ' ' 0 01 - ;4AS2am:::. 0.770 ne. -•'21:56 ,36:90 0r' ,0, ::. p- -'.. p - p. p .:,.. U `-moo :4AS2om �: - .-; U.770 ne ,.. 2156 _-i.36.90 '0*: :.0 0` -: .0' 0"., ;. 0 .0 ..0 W 13AAocs 0.143 se 4.00 2.55 0 0 0 0 0 0 6 0 11 0 11DO 0390 se 1092 11.31 0 0 0 0 0 0 0 0 13A46cs ,-0143 sw; - 400 255 40 ,_ 40 - 160 ,. 102 - 0: -.0 0 .0 1Actom -" -..4270 "` sw -3556 ,: 42:91 �0, 0' 0 '...0 �0-� 0;; 0 f,i0 ;4Ac1o1n..' 1270 sW $5.56 54.02 - . 0 ` .0 ;" 0 ' 0 . ' 0 i - 0 ' -' ' 0 13A-4ccs 0.143 nw 4.00 2.55 0 0 0 0 0 „0 0 0 0 1Actom 1.270 my 35.56 45.24 0 0 0 0 0 0 0 0 `C `• 4AS2omd. 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 IP' 12C-0sw - 0.091 - 2.55 1.28 0 0 0 0 0 : 0 =0 C 16A30md 0.032 - 0.90 2.32 so 50 45 . 116 25 25 .0 22 . 58 -F ..-`'22A4PLi. 0.989' - 27.69 CLOD 50 5 138" .-0. 25 :0' q: .q 6 c)AED excursion 1 01 0 Envelope lossfgain 343 218 22 58 12 a). Infiltration 89 26 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants Q 230 p 0 0 Appliances/other 0 0 0 Subtotal Qines 6 to 13) 433 243 22 58 Less eldemal load 0 0 0 0 Less transfer 0 0 0 0 14 Redistribution Subtotal 6 15 -22 "� 15 Duct loads 34% 52% 4 149 49 135 135 34% 520A 0 0 0 0 Total noon load 392 0 0. Air reauin�(cfm) 2s % 18 q. 0 Calculations approved byACCA to meet all requirements of Manual J Sth Ed A -014- wrightts ft- RlghtSufteO Universal 201717.0.14 RSU08101 2017-Apr-11 09:28:14 ... k CalcslDocuments\WVNNE-MAJESTICMODEL-1608.mp Calc=MJ8 Front Doorfaces: N Page wrightsoit- RiOW@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE M. FT. PIERCE, FL 34946 Phan.: 772466-6799 Fa:c 772466-6796 Emil: OUICKCALCSa(i 1 Room name FOYER 2 =edwall s.o n 3 Room height B.0 ft heaVcad 4 Room dimensions 1.0 x 820 ft 5 Room area 82.0 ft' Ty Construction U-lalue Or HTM Areal Load Load number (Btuldfti°F) (BtuFyft') or perimeter (ft) (etuh) oorrm perimeter _ Heat Coot Gross WP/S Heat Cool Gross WPIS, Heat Cool 6 13A-0(Ws •0143 .ne 4.00 1. 2.55 8 8 32 20 - 4A42cm 0770 ne 21.66 -36.90 0. 0 0 -" 0 - 4AB-2om .0770 ne''"� 21.56 -36.90 0'. 0 0 ' 0.. W 0 13A-0as 0143 se 400 2.55 64 41 165 105 11 11D0 0.390 as 10.92 11.31 23 23 248 267 13A-0ocs -. - -0143 sw -406 255 0 01 0- '0 1Acloms._. - 1270 VV. 3556 .. 42:91 0 .; 0 00 1Aciom ,- 1.270 sw; "3s.5s' '54:6z o 0 0 0 - 1'IN—� 13A4ocs 0.143 inv 4.00 Z55 0 0 0 0 1Ac1om 1.270 nw 35.56 45.24 0 0 0 0 `G 4A5-2omd 0.770 nw 21.56 36.90 0 0 0 0 P. 12"sw• 0.091 ..- 2.65, ' 128 168. 168. ",428. '216.' C 16A-30md_ 0.032 - 0.90 2.32 82 82 73 190 :F ::. '!, 2A 2-tpE,, :,0.989 - -: 2769 ; .::0:00 '. ' -82 : `9 _ 249 : '• 0 .. ". 6 c)AED excursion 0 Envelope loss/gain 1196 788 12 a) InFltraBon 160 45 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal (lines 6 to 13) 1357 834 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 1357 834 15 Duct loads 34�i 5zi, 462 437 Total noun load 1818 1271 Arr required (cfm) 91 57 Calculations approved byACCA to meet all requirements of Manual J 8th Ed ,EA -Fk- wrighYsoft- RI9htSufte® Universal 201717.0.14 RSU08101 2017-Apr-11 09:28:14 ...k CelcslDocumentslWYMJE-MAJESTIC MODEL-1608.rup Cato = MJ8 Front Door faces: N Page 8 Duct S stem Summa Job: wrightlsoft° y � Date: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE I.M. FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-46"796 Email: OUCKCALCS AOLCOM For. WYNNE DEV. THE MAJESTIC, FT. PIERCE, FL Extemal static pressure Pressure losses Available static pressure Supply/ return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.266 in/100ft 1160 cfm 188 Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.266 in/100ft 1160 cfm Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (n) H x W (in) Duct Mat! Actual Ln(ft) Ftg.Egv Ln (ft) Trunk BATH h 587 29 18 0.359 4.0 Ox0 VIFx 24.3 115.0 so BEDROOM 2 c 3381 126 151 0.372 7.0 OxO VIFx 19.4 115.0 st1 DININWGRFAT ROOM o 3558 145 159 0.351 7.0 Ox0 VIFx 27.5 115.0 st1 DININGIGREAT ROOM -A C 3557 145 159 0.287 7.0 Ox0 VIFx 39.4 135.0 st1 DINIWGREAT ROOM-B C 3557 145 159 0.277 7.0 Ox0 VIFx 45.2 135.0 st1 FOYER h 1818 91 57 0.515 4.0 ox0 VIFx 2.0 95.0 KITCHEN C 2175 94 97 0.377 6.0 Ox0 VIFx 17.6 115.0 st1 LAUDRY C 149 3 7 - 0.359 4.0 OxO VIFx 24.3 115.0 st1 M. BATH C 1269 55 57 0.274 4.0 0x0 VIFx 47.4 135.0 st1 MASTER BEDROOM h 3258 163 143 0.266 7.0 0x0 VIFx 52.9 135.0 st1 MASTER BEDROOM -A h 3258 163 143 0.276 7.0 Ox0 VIFx 46.1 135.0 st1 wlc C 223 4 10 0.287 4.0 OxO VIFx 39.0 135.0 st1 Name Trunk Type Htg (Cfm) Clg (cfm) Design FIR Veloc (fpm) Diam Qn) H x W (In) Duct Material Trunk st1 Peak AVF 1069 1103 0.266 1032 14.0 0 x 0 VinlFlx wrilhtsoft 9 RlghtSuite® Universa12017 77.0.14 RSU08101 2017-Apr-11 09:28:15 k& ...k C81cs1D0cuments1WYNNE-MAJESTIC MODEL-1608.nry Calc = MJ8 Front Door faces: N Page 1 Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Dism (in) H x W I (In) Stud/Joist I Opening (in) Duct I Matl Trunk rb1 Ox0 1160 1160 0 1 0 0 0 Ox 0 I VIFx c FJ{} wri htsofr 2017-Apr-110e:26:15 r 9 RightSuile® Universal 2017 17.0.14 RSU08101 Page 2 ...k ColoslDocamentslWYME-MAJESTIC MODEL-1608.mp Calc - MJ8 Front Door faces: N