HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEA
Planning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance SCANNED
BY
Project Name: PARVIN C+ I nrie County
Project Address: 10701 S OCEAN DR LOT 928
Permit #: Occupancy Type: Construction
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
' Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida BUILDING Code Fifth Edition with 20 17 Supplements using ASCE 7-10
2. Structure Designed as (check one): _Enclosed _Partially Enclosed -X—Open
3. Risk Category: _I X II _III _ IV Exposure Category: _B _C X D
4. Design Wind Velocity 165 mph _ASO X LRFD End Zone Width: 1' ft
5. Mean Roof Height 5'+/-DECK HEIGHT ft Roof Pitch: :12 Parapet: ft
6. Components & Cladding Design Pressures Used: (PSF, based on 30sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: Zone 2: Zone 3: Zone 4:+eD'61-64't Zone 5:+70'11-74's Garage:
7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live: Balcony: PSF
Dock: 40 PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF
B. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? _Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT: -
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions -of the building codescurrently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on:4fiese'plans provide adequate resistance to the'design-
forces s� 0%4&11111//� s ,
p AIEL ftf /ll� : DANIEL PAUL RETHERFORD 72451
®� ''� • [%�'P '- Pririt'Name _ Cert # & Co. Cert Auth.
•4
�ttf nd Seal = :'1402',HARTMAN ROAD, FT PIERCE, FL 34947
Ili � (Company Name & Address
Revised 07/25/2614.
(qv2 -cV5
ST. LUCIE COUNTY
BUILDING DIVISIO
REVIEWED
FOR COM A
REVIEWED BY
DATE
PLANS AND P RMIT
MUST BE KEPT JOB OR
NO INSPECTION WI L BE MADE
THESE PLANS AND ALL PROPOSED �'t�pRiC
ARE SUBJECT TO ANY CORRECTIONS
'REQUIRED BY FIELD INSPECTORS THAT
MAYBE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODES.
CONCULED FASTENERS ORAITACHMENTS
ARE THE RESPONSIBILITY OF THE
CONTRACTOROFRECORO