Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEA Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance SCANNED BY Project Name: PARVIN C+ I nrie County Project Address: 10701 S OCEAN DR LOT 928 Permit #: Occupancy Type: Construction INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. ' Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida BUILDING Code Fifth Edition with 20 17 Supplements using ASCE 7-10 2. Structure Designed as (check one): _Enclosed _Partially Enclosed -X—Open 3. Risk Category: _I X II _III _ IV Exposure Category: _B _C X D 4. Design Wind Velocity 165 mph _ASO X LRFD End Zone Width: 1' ft 5. Mean Roof Height 5'+/-DECK HEIGHT ft Roof Pitch: :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on 30sgft @ 15'MRH, clearly label on all plan openings): Zone 1: Zone 2: Zone 3: Zone 4:+eD'61-64't Zone 5:+70'11-74's Garage: 7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live: Balcony: PSF Dock: 40 PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF B. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? _Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: - I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions -of the building codescurrently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on:4fiese'plans provide adequate resistance to the'design- forces s� 0%4&11111//� s , p AIEL ftf /ll� : DANIEL PAUL RETHERFORD 72451 ®� ''� • [%�'P '- Pririt'Name _ Cert # & Co. Cert Auth. •4 �ttf nd Seal = :'1402',HARTMAN ROAD, FT PIERCE, FL 34947 Ili � (Company Name & Address Revised 07/25/2614. (qv2 -cV5 ST. LUCIE COUNTY BUILDING DIVISIO REVIEWED FOR COM A REVIEWED BY DATE PLANS AND P RMIT MUST BE KEPT JOB OR NO INSPECTION WI L BE MADE THESE PLANS AND ALL PROPOSED �'t�pRiC ARE SUBJECT TO ANY CORRECTIONS 'REQUIRED BY FIELD INSPECTORS THAT MAYBE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. CONCULED FASTENERS ORAITACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOROFRECORO