Loading...
HomeMy WebLinkAboutLETTER FROM PAUL WELCH"F PAUL WELCH INC. Mechanical Electrical Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 Phone (772) 785 - 9888 E-mail pwelchinc@aol.com February 11, 2019 Re: Hansen Re -Roof 10725 S Ocean Dr. 214 Jensen Beach' 34957 SCANNED BY St. Lucie County SCOPE OF WORK:' Install new Metal Roof (Extreme Metal Fabricators, LLC "5-V Crimp" FL #17022.1) at above referenced address over new underlayment, and existing plywood sheathing. DESIGN CRPI'ERIA• FBC 2017 ASCE7-10 PROJECT DATA: BUILDING HIEGHT=12'-0" A= 3' MEAN ROOF HIEGHT = <23' ROOF ANGLE = 5:12 SHAPE = PITCHED GABLE ADJUSTMENT FACTOR = 1.00 IMPROTANCE FACTOR = 1.00 I D� • O t7 WIND VELOCITY V ult = 165MPH WIND VELOCITY V asd =128 MPH EXPOSURE E D FILE COPY ENCLOSURE CLASS =ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT = -0.18 ZONE 1 (Field) = -40.3 ZONE 2 (Perimeter/ Ridge) = -68.0 ZONE 3 (Comers) = -99.8 Paul Welch Inc. Paul Welch P.E. Reg. No. 29945 February 11, 2019 10725 S Ocean Dr. 214 Jensen Beach, FL 1 of 3 Metal roofing to be attached with corrosion resistant Hex -Head wood screws #10 x 1 V? minimum with weather sealing washers (minimum 3/16" penetration through deck). Fasteners shall be placed through the panel ribs at 12" on center across panel width and spacing along the ribs as follows: ZONE 1 (Field): FASTENER SPACING =16" O.C. ZONE 2 (Perimeter/ Ridge): FASTENER SPACING = 16" O.C. ZONE 3 (Comers): FASTENER SPACING = 8" O.C. NOTE: PROVIDE LAP SEALANT FOR ALL ROOF PANEL LAPS FOR ROOF SLOPES UNDER 3 VERT.:12 HORZ. Design uplift Pressure for attachment as per above: Product Design Pressure: Zones 1 & 2:-93.5PSF / Zone 3:-101PSF Therefore O.K. UNDERLAYMENT: Underlayment shall be in accordance with manufacturer's guidelines, FBC 1507.4.5.1, and FBC 15074.5.2. Underlayment shall be 30# Roofing Felt. DECK INSTALLATION: Re -nail all plywood sheathing (15/32" thick minimum) with 8D ring -shank nails at 4" O.C. Perimeter and 6" O.C., field for all zones. All work to be in compliance with product approval (FL # 17022.1), manufacturer's specifications, and the Florida Building Code 2017. 10725 S Ocean Dr. 214 Jensen Beach, FL _ Paul Welch Inc. Paul Welch P.E. Reg. No. 29945 February 11, 2019 2of3' 0 Ga��C 11� ROOF ZONE PLAN A=3' 01 ,M = ZONE DESIGNAMN (TYPICAL) NOTE: PROVIDE LAP SEALANT FOR ALL ROOF PANEL LAPS FOR ROOF SLOPES UNDER 3 VERT.:12 HORZ. Paul Welch Inc. Paul Welch P.E. Reg. No. 29945 / February 11, 2019 10725 S Ocean Dr. 214 Jensen Beach, FL 3 of 3