Loading...
HomeMy WebLinkAboutEVALUATION REPORTSEXTERIOR RESEARCH & DESIGN, I.I.C. Certificate of Authorization #9503 NTINITY ERD RECEIVED 353 CHRISTIAN STREET, UNIT#13 NAMED OXFORD, CT 06478 BY (203)262-9245 EVALUATION REPORT FEB 19 ' v19 Qf 1 .-Pies I^ntivtft^ Owens Corning "T01ilbation Report 037940.02.12-R8 One Owens Corning Parkway -ST. _�CP,tt9AM, eer.4f�4it9 Date of Issuance: 02/06 2012 Toledo, OH 43659 �O N / (740) 404-7829 0 �/1 Revision 8: 10/09/2017 SCOPE: C2,NA.\�I 1 ��� v2� This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. CONCMMFASTENERSORATTACHMENTS DESCRIPTION: OwensCorntn s a Roo S nT es ARETHE RESPONSIBILITY OF THE CONTRACTOR OR RECORD LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1 / R905.2.6.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity[ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinityl ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8 THESE PLANS AND ALL PROPOSED WORK Prepared by: �r".,'-ARE SUBJECT TO ANY CORRECTIONS BY FIELD INSPECTORS THAT .'!TRAY BE NECESSARY IN ORDER TO - COMPLY WITH ALL APPLICABLE CODES. Robert J.M. NlemineO P.E.•'^--1"•�``' ThefacsI mile sea la appearing was authorized Robert i qiu^/ONa1.B�..S , PP 6 Y Florida Registration No. 59166, Florida DCA ANE1983 ;-..fin,"^ Nieminen, P.E. an 10/09/2017. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2.. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity[ ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ' ST. LUCIE CO BUILDING DI ION i REVIEWED FOR COM DANCE � A -4 PLAISYANDTIERMITIMUST BE KEPT SITE OR NO INSPECTIONS) WILL I - TRINITY ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated_ compliance with the following sections of the 6`h Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section 1507.2.5, R905.2.4 1507.2.7.1, R905.2.6.1 1507.2.7.1, R905.2.6.1 3. REFERENCES: Entity UL LLC(CER9626) UL LLC (CER9626) UL LLC (TST9628) UL LLC (TST9628) UL LLC (TST9628) UL LLC (TST9628) UL LLC (TST9628) UL LLC (TST9628) Miami -Dade (CER3592) ULLLC (QUA9625) 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: Property Physical Properties Wind Resistance Wind Resistance Examination Physicals & Wind Resistance Physicals & Wind Resistance Physical Properties Wind Resistance Physicals & Wind Resistance Wind Resistance Physical Properties Physical Properties FBC HVHZ Compliance Quality Control Standard ASTM D3462 ASTM D3161 ASTM D7158 Reference File R2453, Vol. 3 20120516-112453 06CA20263 11CA34308 4786093137 4786126532 Classification letter Classification letter Various NOAs Service Confirmation Year 2010 2016 2011 Date 02/15/2007 05/16/2012 04/19/2006 02/18/2012 02/01/2014 02/10/2014 02/13/2014 10/02/2015 Various Exp.05/16/2020 4.1.1 Classic and Supreme are fiberglass reinforced, 3-tab asphalt roof shingles. 4.1.2 Berkshire are fiberglass reinforced, 4-tab asphalt roof shingles. 4.1.3 Devonshire" are fiberglass reinforced, 5-tab asphalt roof shingles. 4.1.4 Duration', rru iefniton uration, Duration Premium Cool, TruDefinition Duration Designer Color Collection, TruDefinition Oakridge , Oakridge and WeatherGuard' HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Hip & Ridee Shingles: 4.2.1 Berkshire Hip & Ridge Shingles, High Ridge, WeatherGuard, HP Hip & Ridge Shingles, Shingles and DuraRidgeT" Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Accessory Starter Strips: 4.3.1 Starter Strip Shingle, Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design, U.C. Evaluation Report 037940.02.12-118 Certificate of Authorhation#9503 r EDmON(2017) F8C NON-HVHZ EVALUATION FL10674-R13 Owens Coming Asphalt Roof Shingles Revision 8: 10/09/2017 Page 2 of 8 ,, I KINrry ERD 5.4 Wind Classification: 5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for use in all wind zones up to Vasd = 150 mph (Vuh = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, -Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to Vasd =150 mph (Vuh = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. 6. INSTALLATION: 6.1 Underlavment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: ➢ Berkshire shingles require minimum five (5) nails per shingle. ➢ WeatherGuard* HP shingles require minimum six (6) nails per shingle. ➢ Devonshire TM shingles require minimum six (6) nails per shingle. ➢ Starter Strip Shingle and Starter Strip Plus require minimum five (5) nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing —Starter Strip Shingle and Starter Strip Plus: Exterior Research and Design, U.C. Evaluation Report 037940.02.12-R8 Cert(Prate of Authorization #9503 6Ta EDITION (2017) FBC NON-HVHZ EVALUATION F1.10674-1133 Owens Coming Asphalt Roof Shingles Revision 8: 10/09/2017 Page 3 of 8 6.2.6 Minimum Nailing— Classic®&Supreme: Normal Mansard or Area pare Wind Arena High Wind d.evenasy Area pare wentoa nozmales Areas vlontns /uerfaa t (AI s t r IS s• sr 5 Esposuro Eepoelefdn 6.2.7 Minimum Nailing — Berkshire®: Cahn strip G Iva de reHade sti~• eve a 9W ' • aw ,. ,.1 Standard Fastening Pattern \I I KINITY ERD Normal Mansard or Area pare Wind Areas Nigh Wind doavanas y Arsn paw vfentos normelee Arens rfentas /uertse '12 e Stir Exposure EapoelNdn Mansard or Steep Slope Fastening Pattern Exterior Research and Design, LLC. Evaluation Report 037940.02.12-RB Certificate of Authorization a9sa3 6r"EDITION (2017)FBC NON-HVH2 EVALUATION F1.10674-1133 Owens Corning Asphalt Roof Shingles Revision 8: 10/09/2017 Page 4 of 8 rTRINITYIERD 6.3 Hip & Ridge Shingles: 6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuard HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using four (4) nails per shingle. Installation of DuraRidge'" Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of -hand-sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing — Berkshire® Hip & Ridge and High Ridge: Fig 2 roNvle. smavtes Nala Ntlb r r T-PL tlm �' t s• was t• 1 I i gl a• �I I �I I I 6.3.4 Minimum Nailing— WeatherGuard® HP Hip and Ridge: Fig. C Hip & Ridge Shingle Fastening TopvN ' Nalb Halts T' 1' 1' 1" 1 s• FYpaaNre L tY �I Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R8 certificate of Authorization #9503 Go' EDITION (20171 FBC NON-HVHZ EVALNATION FL30674-R13 Owens Corning Asphalt Roof Shingles Revision 8: 10/09/2017 Page 7 of 8 6.3.5 Minimum Nailing - ProEdge Hip & Ridge Shingles: Prevailing Wind Direction Sodont Strip *0'� 0' Exposure Cover Exposed FMonan with Roof Convent �I TRINITY ERD 6.3.6 Minimum Nailing— DuraR(dge'" Hip & Ridge Shingles: Note: The drawings below pertain to minimum, as -tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. 14arnih'Wvlo1ncdm Dimdinndvni=todrrnt Diromfnd.Nxvn prodvni.to 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 CIA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625 ; (631) 546-2458; Kanchi.Agrawala-Dokania@ul.com - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report 037940.02.12-118 Cealflcate of Authorizotion&9503 6r"EDITION (2017)FBC NON-HVH2 EVALUATION FL10674-R33 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 8 of 8 RECEIVED FEB 13 2019 ST. Lucie Gann s p@Ytnittin t MEMO I etc. Certificate ofAuthorizotion #32455 SCANNED 353 Christian Street, Unit #13 BY Oxford, CT 06478 F..11rip CalIn4.. (203) 262-9245 ---ENGINEER - -EVALUATE - - - 'TEST - - - -CONSULT -CERTIFY Polyglass USA, Inc. 150 Lyon Drive Fernley, NV 89408 (954) 233-1330 Revision 22: 10/08/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed'by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 61h Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: oyi; ass SBS and APP Modified Bitumen Roof15 lem LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEM01etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4, plus a 65-page Appendix. Prepared by: et""""1••• '- /per// ��—,---'"— Robert 1.M.Nieminen, P.E. - •ff The facsimile seal appearing was authorized by Robert Florida Registration No. 59166, Florida DCA ANE1983 '^;:, ;�?;� u�^,• " Nieminen, P.E. on 10/06/2018. This does not serve as an ' electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial Interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ONEMO etc. ROOFING SYSTEMS EVALUATION: Product Category: Roofing Sub -Category: Modified Bitumen Roof Systems. Compliance Statement: Polyglass SBS and APP Modified -Bitumen Roof Systems, as produced by-Polyglass—USA, — Inc., have demonstrated compliance with the following sections of the 61h Edition (2017) Florida Building Cade through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. STANDARDS:2. Section Pro a Standard Year 1504.3.1 Wind FM 4474 2011 1504.3.1 Wind UL 1897 2012 1504.7 Impact FM 4470 2012 1507.12.2 Physicals ASTM D6162 2008 1507.11.2 Physicals ASTM D6163 2008 1507.11.2 Physicals ASTM D6164 2011 1507.11.2 Physicals ASTM D6222 2011 1507.11.2 Physicals ASTM D6509 2009 3. REFERENCES: Entity Exam Reference Date Entity Exam Reference Date ERD (TST6049) Physicals P10490.10.08-2 10/30/2008 FM (TST1867) FM 4470 200ABAM 12/23/1998 ERB(TST6049) FM 4470/4474 P33760,09.09 09/10/2009 FM(TST3867) FM 4470 2D5A9.AM 06/22/1999 ERB(TST6049) FM 4470/4474 P33770.09.09 09/10/2009 FM (TST1867) FM 4470 3006646 01/04/2000 ERD (TST6049) FM 4470/4474 P30540.11.09-R3 11/30/2009 FM (TST1867) FM 4470 3001334 01/25/2000 ERD(TST6049) FM 4470/4474 P30550.12.09 12/02/2009 FM (TST1867) FM 4470 3001334 02/15/2000 ERD (TST6049) Physicals P33960.12.10 12/30/2010 FM (TST1867) FM 4470 30WS57 01/12/2000 ERD (TST6049) FM 4470/4474 P33970.03.11 03/15/2011 FM (TST1867) FM 4470 3004091 01/12/2000 ERD (TST6049) Physicals P37590.03.13-3A 03/0612013 FM (TST1867) FM 4470 3006115 05/02/2001 ERD (TST6049) FM 4470/4474 P39680.03.13 03/04/2013 FM (TST1867) FM 4470 3012321 07/29/2002 ERD (TST6049) Physicals P37590.03.13-1-RI 06/26/2013 FM (TST1867) FM 4470 3014692 08/05/2003 ERD (TST6049) Physicals P37590.03.13-2-RI 07/01/2013 FM(TST1867) FM 4470 3014751 08/27/2003 ERD (TST6049) Physicals P37590.07.13-2 07/01/2013 FM (TST1867) FM 4470 3007170 01/13/2004 ERD (TST6049) Physicals P37590.03.13-5-RS 07/01/2013 FM (TST1867) FM 4470 3019317 06/20/2004 ERD (TST6049) Physicals P37590.07.13-1 07/02/2013 FM OST1867) FM 4470 3020703 07/30/2004 ERD (TST6049) FM 4470/4474 P41630.08.13 08/06/2013 FM (TST1867) FM 4470/4474 3018332 01/31/2006 ERD (TST6049) Physicals P45940.09.13 09/04/2013 FM (TST1867) FM 4470/4474 3023368, 03/20/2006 ERD (TST6049) Physicals P44370.10.13 10/04/2013 FM (TST1867) FM 4470/4474 3024594 05/23/2006 ERD (TST6049) Physicals P39520.09.14-2 09/11/2014 FM (TST1867) FM 4470/4474 3023458 07/18/2006 ERD (TST6049) FM 4470/4474 506160.11.14 11/10/2014 FM (TST1867) FM 4470/4474 3030668 09/12/2007 ERD (TST6049) Physicals P454405C.03.35.1 03/31/2015 FM (TST1867) FM 4470/4474 3032172 06/12/2009 ERD (TST6049) Physicals SC5170.05.15 05/08/2015 FM (TSTISG7) FM 4470/4474 3049631 04/21/2014 ERD (TST6049) FM 4474 SC8085.05.15 05/19/2015 FM (TST1867) FM 4470/4474 3057029 02/02/2017 ERD(TST6049) Physicals SC5170.12.15 12/29/2015 NEMO(TST6049) Criticality 46-PLYG-1M01o6.18 06/23/2018 ERD (TST6049) FM 4470/4474 SC9455.15 04/01/2016 NEMO(TST6049) FM 4474 4L-PLYG-38003.08.18 08/21/2018 ERD (TST6049) 4M 4470/4474 PLYG.SC8905.05.16.1 05/17/2016 NEMO(TST6049) FM 4474 PLYG-Cl. C3. ra, C5, CO 09/21/2018 ERD (TST6049) FM 4470/4474 PLYG-SCA905.05.16-2 05/17/2016 NEMO(TST6049) Criticality 45-PLYG-18-001.10-10 10/03/2018 ERD (TST6049) FM 4470/4474 PLYG-SC10815.07.16-R1 09/23/2016 PRI (TST5878) Physicals PUSA-062-02-01 12/04/2007 ERD(TST6049) UL1897 PLYG-SC12025.30.16 10/12/2016 PRI(TST5878) Physicals PUSA-061-02.02 01/28/2008 ERB(TST6049) FM 447014474 PLYG-SC11475.16 11/17/2016 PRI(TSTS878) Physicals PUSA 064-02-02 02/27/2008 ERD (TST6049) FM 4470/4474 PLYG.SC13235.01.17 01/17/2017 PRI(TST5878) Physicals PUSA-062-02-02 12/04/2008 ERD (TST6049) FM 4470/4474 PLYG.SC13920.05.17 05/30/2017 PRI(TST5878) TAS 114 PUSA-188-02-01 02/08/2017 ERD(TST31294) FM 4470/4474 PIYGtTL13945.05.17-1 05/30/2017 PRI(TST5878) TAS 114 PUSA-188-02-02 02/08/2D17 ERD(TST11294) FM 4470/4474 PLY&C1113945.05.17.3 Bs/30/2017 PRI(TST5878) TAS 114 PUSA-188-02-03 02/08/2017 ERD (TST6049) FM 4470/4474 PLYG-SC13945.05.17 05/30/2017 PRI(TST5878) TAS 114 PUSA-202-02-01 05/17/2017 ERD(T5TG049) FM 4470/4474 PLYG-SC1576.0.09.17 09/11/2017 PRI(TST5878) TAS 114 PUSA-202-02-02 05/17/2017 FM (TST1867) FM 4470 2W7A7.AM 08/04/1994 M-D(CER1592) HVHZ Various NOM Various FM (TST1867) FM 4470 003A3.AM 04/04/1997 M-D (CER3592) Prop. for Rev. 10-0923 10/12/2010 UL(QUA9625) Quality Control Service Confirm 09/13/2018 NEMO ETC, LLC Evaluation Report P9290.02.08-1121 Certificate of Authorization N32455 618EDITION (2017)FBC NON-HVHZ EVALUATION FL3654-R23 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 22: 10/08/2018 Page 2 of 4 ONEMO etc. This Evaluation Report covers Polyglass Modified Bitumen Roof Systems installed in accordance with Polyglass USA, Inc. published installation instructions and the Limitations / Conditions of Use herein. The following Polyglass membranes make up the subject systems. TABLE Type 1: ROLL -GOODS FOR POLYGLASS MODIFIED BITUMEN Product ROOF SYSTEMS Specification Reference Grade Type Base Sheets Polyglass G2 Base ASTM D4601 N/A II Polyflex SA Base ASTM D4601 N/A II Polyglass APP Base ASTM D6509 N/A N/A SBS Membranes Polyglass HT Base 650 ASTM D6162 S III Elastobase ASTM D6163 S I Elastoflex V ASTM D6163 S I Elastoflex SA V Base ASTM D6163, Table 2 S I ElastaS(eXSA V FR Base ASTM D6163, Table 2 S 1 Elas ofle�i SAtiV Plus ASTM D6163 S I Elastoflex SA V Plus FR ASTM D6163 S I Elastobase Poly ASTM D6164 S I Elastoflex S6 ASTM D6164 S I Elastoflex S6 Type 11 ASTM D6164 S II Elastoflex VG ASTM D6163 G I Elastoflex VG FR ASTM D6163 G I SBS Membranes Elastoflex S6 G ASTM D6164 G I Elastoflex S6 G FR ASTM D6164 G I Polyfresko G SBS (sand or poly -film back) ASTM D6164 G I PolyfreskoG SBS FR sand or poly -film back) ASTM D6164 G I Elastoshield TS G ASTM D6164 G I Elastoshield TS G FR ASTM D6164 G I Elastoflex SAP ASTM D6164 G I Elastoflex SA P FR ASTM D6164 G I Polyreflect ASTM D6164 S I APP Membranes Polyflex ASTM D6222 S I elY ASTM D6222 G I Po y ex G FR ASTM D6222 G I Polyfresko G ASTM D6222 G I Polyfresko G FR ASTM 06222 G I Polybond ASTM D6222 S 1 Polybond G ASTM D6222 G I Polyflex SA P ASTM D6222 G I Polyflex SA P FR ASTM D6222 G I Polyfresko G SA ASTM D6222 G I Polykool ASTM D6222 S I 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 5.4 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4 unless the exceptions stated In FBC 2603.4.1 and 2603.6 apply. NEMO ETC, LLC Evaluation Report P9290.02.08-R21 Certifimte ofAuthorhotion d32455 6- EDITION(2017) FBC NON-HVHZ EVALUATION FL1654-R23 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 21: 10/08/2018 Page 3 of 4 ONEMOletc. 5.5 The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.6 For recover installations, the existing roof shall be examined in accordance with FBC 1511. 5_:_7 For _mechanically attached insulation or membrane or strip bonded insulation, the. maximum. design-pressure-focthr selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD3, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk' carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.8 For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 5.10 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM. Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.11 For bonded insulation or membrane over existing substrates In a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TM 124. 5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or Roofing Application Standard RAS 111, except the basic wind speed shall be determined from FBC Figure 1609.3(1), 1609.3(2) or 1609.3(3). 5.13 All products in the roof assembly shall have quality assurance in accordance with FAC Rule 61G20-3. 6.1 Polyglass Modified Bitumen Roof Systems shall be installed in accordance with Polyglass USA, Inc. published installation instructions, subject to the Limitations / Conditions of Use noted herein. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. Contact the noted QA agency for information on product locations covered for F.A.C. Rule 61G20-3 QA requirements 9. QUALITY ASSURANCE ENTITY: UL LLC— QUA9625; (314) 578-3406, k.chancellor@us.ul.com - THE 65-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - NEMO ETC, LLC Evaluation Report P9290.02.08-1121 Certificate ofAuthorimtion H32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION FL1654-R23 Polyglass Modified Bitumen Roof Systems; (9541233-1330 Revision 21: 10/08/2018 Page 4 of 4 ONEMOIetc. AP PEN DIX 1: ATTACHM ENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE TABLE DECK I APPLICATION TYPE DESCRIPTION PAGE 1A Wood New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 5 1B Wood New or Reroof (Tear -Off) A72 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5-9 SC Wood New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 10-11 1D Wood New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 12 1E Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 12-14 1F Wood New, Reroof (Tear -Off) or Recover D Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 15-17 iG Wood New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover 18-21 1H Wood New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet (screws 8, plates), Bonded Roof Cover 21-25 11 0 -O 2A Steel or Structural concrete New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 27-29 2B Steel or Structural concrete New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 30-34 2C Steel or Structural concrete New, Reroof (Tear -Off) or Recover D Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 35-37 3A Structural concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 38-46 3B Structural concrete New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 46 4A Lightweight concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 47-49 4B Lightweight concrete New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 50 4C Lightweight concrete New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 51-53 5A Cementitious wood fiber New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 54 SB Cementitious wood fiber New, Reroof (Tear-Of)or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 55 SC Cementitious wood fiber New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 56 SO Cementitious wood fiber New, Reroof (Tear -Oft) or Recover C Mech. Attached Insulation, Bonded Roof Cover 56 SE Cementitious wood fiber New, Rer0Df (Tear -Off) or Recover E Non -Insulated, Mach. Attached Base Sheet, Bonded Roof Cover 56 6A Existing gypsum Reroof (Tear -Off) A-1 'Bonded Insulation, Bonded Roof Cover 57-59 6B Existing gypsum Reroof (Tear -Off) or Recover A-2 I Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 59 6C Existing gypsum Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 60 BID Existing gypsum Reroof (Tear.Oft) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 60 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 61-65 76 Various Recover F Non -Insulated, Bonded Base Sheet, Bonded Roof Cover 65 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement: Wood: Minimum 0.75-inch penetration. Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck. ➢ Structural concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturers published installation Instructions. NERAO ETC, LLC Evaluation Report P9290.02.08-R21 for FL1654-RZ3 Certificate of Authorization I22455 bra EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 10/08/2018 Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 1 of 65 ONEMOletc. 3. Unless otherwise noted, insulation maybe anyone layer or combination of polyisocyanurate,polystyrene, wood fiberboard, perlite,gypsum-based roof board or mineral -wool roof board that meets the QA requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. 4. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete maybe substituted for rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural decks ha I I be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016). 6. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published instructions. D Hot asphalt (HA): Full coverage at 25-30lbs/square. ➢ Dow INSTA STIK Quik Set Insulation Adhesive (D-IS): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c. D Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons, 12-Inch o.c. ➢ Millennium PG-1 Pump Grade Adhesive (M-PG3): Continuous 0.25 to 0.5-inch wide ribbons, 12-Inch o.c. D OMG OlyBond 500 (08500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. (PaceCartor SpotShot). Note: OlyBond Green maybe used where OlyBond5001s referenced. ➢ OlyBond Classic (OB Classic): Full coverage at 1 gal/square. D ICP Adhesive& SealantslPolyset CR-20: Continuous 2.S-3.5-inch wide ribbons, 12-Inch o.c. D Note: When multiple lay ers(sJ of insulation and/or coverboard are installed in ribbon -applied adhesive, board joints shall be staggered. D Note; The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7. Unless otherwise noted, all Insulations are Hat -stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations maybe substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to 'increase' the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed fora particular system in the tables, then the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table: D Millennium One Step Foamable Adhesive(M-OSFA): MDP -157.5 psf (Min. 0.5-inch thick) D Millennium PG-1 Pump Grade Adhesive (M-PGS): MDP -157.5 psf (Min. 0.5-inch thick) D OMG OlyBond 500 (OB500): MDP -45.0 psf (Min. 0.5-inch thick Multi -Max FA-3) D OMG OlyBond 500(OB500): MDP -187.5 psf (Min. 0.5-Inch thick ISO 95+GL) D OMG OlyBond 500 (08500); MDP -315.0 psf (Min. 0.5-Inch thick ENRGY 3) D OMG OlyBond 500 (06500): MDP -487.5 psf (Min. 0.5-inch thick ACFoam II) ➢ICP Adhesives& Sealants Polyset CR-20: MDP -117.5 psf (Min. 1.0-inch thick) 8. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 9. For mechanically attached components or partially bonded insulation, the maximum design pressure for theselected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDl, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk- carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 10. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. 11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12. For existing substrates in a bonded recover or re -roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet.1-52 or Testing Application Standard TAS 124. 13. For Recover Applications using System Type D, the insulation is optional;however, the existing roof system shall be suitable for a recover application. NEMO ETC, LLC Certificate of Authorization #32455 Prepared by: Robert Nieminen, PE-59166 0 EDTTION 12017) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-1121 for FL1654-1323 Revision 21: 10/09/2018 Appendix 1, Page 2 of 65 i ONEMOjetc. 14. Lightweight Insulating Concrete (LWC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWC Product Approval for specific beck construction and limitations. Unless otherwise noted, for systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat thickness is 2-inches. For LWC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. For "pre-existent" LWC references, listings were established through testing over lightweight concrete cast using only foaming agent (ASTM C896), water and Portland cement (ASTM C150), with no proprietary additives, in accordance with procedures adopted by Miami -Dade BCCO (FBC CER1592). Unless otherwise noted, use of these listings in new construction or re -roof (tear -off) applications is at the discretion of the Designer or Record and Authority Having Jurisdiction. 15. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications , POLYGLAss F COVERS REFERENCE MATERIAL APPLICATION BP -AA One or more plies Polyglass G2 Base, FBC Approved ASTM D4601, Type II - (Base and Ply sheets,One or more plies Polyglass Ply IV, Polyglass Ply VI, FBC Approved ASTM D2178, Type IV or VI Hot Asphalt at 20-40 Asphalt -Applied) Asphalt -applied sheets or insulation shall not be applied to poly -film surfaced membranes. Ibs/square 7BFase One ply Elastobase (sand/sand), Elastoflex V, Elastoflex 56, Elastoflex 56 Type II, Polyglass HT Base 650 SBS-CAS ply Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex 56 Type II, Elastoflex S6 G, Elastoflex 56 G FR, Elastoshleld TS-G, Elastoshield PG350 at 1.5-2.0 gal/square TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed) One ply Elastobase (sand/sand), Elastoflex V, Elastoflex S6; Elastoflex 56 Type IIPolyplus SBS-CA2 Elastoflex VG, Elastoflex VG FR, Elastoflex 56, Elastoflex S6 Type II, Elastoflex S6 G, Elastoflex 56 G FR, Elastoshield TS-G, Elastoshield 35 at 1.5-2.0 TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed) gal/square - Base Ply or Ply One or more plies Elastobase (sand/sand or poly/sand), Elastobase P (sand/sand or poly/sand), Elastoflex V, Elastoflex 56, Elastoflex 56 Type II, Polyglass HT Base 650 SBS-AA Hot Asphalt at 20.40 (SBS, Asphalt -Applied) Cap Ply Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex S6, ElastoRex 56 Type II, Elastoflex S6 G, Elastoflex 56 G FR, Elastoshield TS-G, Ibs/square Elastoshield TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR sand -backed) Note: Asphalt -applied sheets or insulation shall not be applied to poly -film surfaced membranes: Base Ply or Ply One or more plies Elastobase (sand/poly), Elastobase (poly/poly), Elastoflex V, ElastoRex S6, Elastoflex 56 Type II, Polyglass HT Base SBS-TA 650 (SBS, Torch -Applied) Cap Ply Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex 56, Elastoflex S6 Type II, Elastoflex S6 G, Elastoflex 56 G FR, Elastoshield TS- Torch -Applied G, Elastoshield TS-G FR, Polyfresko G SBS (poly -film backed), Polyfresko G SBS FR (poly -film backed) Base Ply One or more plies Elastoflex SA V Base, Elastoflex SA V FR Base, Elastoflex SA V Plus, Elastoflex SA V Plus FR SBS-SA Cap Ply Elastoflex SA P, Elastoflex SA P FR, Polyreflect (SBS, Self -Adhering) Note: Unless otherwise noted, permissible membrane substra[esfar SBS-SA are limited to the 585•SA Base Ply options he rein, Self -Adhering Elastobase (poly/sand) or Elastobase (poly/poly). APP-CA3 Cap Ply Polyflex G FR PG350 at 1.5-2.0 gal/square APP-TA Base Ply or Ply One or more plies Polyglass APP Base, Polyflex, Polybond (APP, Torch -Applied) Cap Ply PolyOex, Polyflex G, Polyflex G FR, Polybond, Polybond G, Polyfresko G, Polyfresko G FR Torch -Applied APP SA Cap Ply Polyflex SA P, Polyflex SA P FR, Polyfresko G SA, Pclykool (APP, Self -Adhering) Note: Unless otherwise noted, permissible membrane substratesforAPP-SA are limited to the SBS-SA Base Ply options herein, Self -Adhering Elastabase (poly/sand) or Elastobase (Poly/poly). NEMO ETC, LLC Evaluation Report P9290.02.08-R21 for FL1654-R23 Certificate of Authorization #32455 6" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 10/08/2019 Prepared by: Robert.Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 3 of 65 NNEMOjetc. TABLE If: .... .. . . .:... ROOF System Roof Cover (Note 15) No. Deck (Note 1) Primer MOP (psf) Joint Treatment Base Ply Ply Cap Ply W-170 Min. 15/32- None None SBS-SA (Optional) SBS-SA, SB5- SBS-SA, APP-SA, SBS. -90.0 inch plywood TA, APP TA TA APP TA Min. 15/32- W-171 inch plywood (Optional) PG300 None Pol YO ex SA Base (Optional) APP-TA APP-TA -90.0 W 172 Min. 15/32- pG100 None SBS-SA (Optional) SBS-SA, SBS- SBS-SA, APP-SA, SBS- g7 S Inch plywood TA, APP-TA TA, APP-TA Min. 15/32- Plywood joints are covered with 4-inch wide strips of ElastoBex SA V Plus, rolled into ElastoBex SA V Base or (Optional) SBS-SA, SBS- SB5-SA, APP-SA, SBS- W-173 inch plywood (Optional) PG100 place to create continuous bond. ElastoBex SA V FR Base TA, APP-TA TA, APP-TA -97.5 W 174 Mch POLYBRITE 745 None SBS-SA 585- -SA, 5B5- -105.0 inch Plywood plywood TA, APP TASBS-SA, TA, APP TA W175 2 (Optional)PGI00 4Ywpvdj�otq'S'!a re W04-inch widE strips fEtastot#Ex•SA!i'Ff s, rplled into ElastaflEv SA VPIus or (Opt oinylT3BS5A'�5 - 85.5A-AFP-SA-S85-.,- Alyiuno lace o createE nt....�uSb Efasto ex ' PI R _ Min. 15/32- Plywood joints are covered with 4-Inch wide strips of Elastofex SA V Plus, rolled into W-176 inch plywood 0 (Optional) ) PG100 place to create continuous bond. ez Pol YB SA Base (Optional)APP-TA APP-TA -135.0 NEMO ETC, LLC Evaluation Report P9290.02.08-R21 for FL3654-RZ3 Certificate of Authorization 932455' 6TM EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 10/08/2018 Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (954) 733-1330 Appendix 1, Page 26 of 65