HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: ANISOM ADDITION Builder Name: Street: 9221 WENTWORTH WAY Permit Office: SC���� City, State, Zip: PORT ST. LUCIE , FL, Permit Number: BY Owner. Jurisdiction: 5t Lug county Design Location: FL, Fort Pierce County: St Lucia (Florida Climate a tone 1. New construction or existing Addition 9. Wall Types(256.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 256.00 ft' b. NIA R= ft' 3. Number of units, if multiple family 1 a N/A R= ft , 4. Number of Bedrooms(Bedrms In Addition) 0(0) d. NIA R= ft' 5. Is this a worst case? No 10. Ceiling Types (248.0 sqft.) Insulation Area a. Under Attic (Vented) R=19.0 248.00 ft 6. Conditioned floor area above grade (ft) 248 b. WA R= ft' Conditioned floor area below grade (ft2) 0 c. NIA R= ft' 11. Ducts R ft' 7. Windows(40.0 sqft.) Description Area a. Sup: Attic, Rot: Attic, AH: Main 6 49 a. U-Factor. Sgl, U=0.65 40.00 ft' SHGC: SHGC=0.25 b. U-Factor: WA ft' 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 46.0 SEER:14.00 c. U-Factor. WA ft' SHGC: 13. Heating systems kBtulhr Efficiency d. U-Factor: NIA ft2 a. Electric Strip Heat 34.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.260 14. Hot water systems- None required 8. Floor Types (248.0 sqft.) Insulation Area a. Cap: N/A EF: 0.000 a. Slab -On -Grade Edge Insulation R=0.0 248.001N b. Conservation features b. N/A R= ft c. N/A R= ft' 15. Credits CF. Patel Glass/Floor Area: 0.161 Total Proposed Modified Loads: 11.67 PASS Total Baseline Loads: 12.20 I hereby certify that the plans and specifications covered by Review of the plans and Spg7e this calculation are in compliance with the Florida Energy specifications covered by this 04TH6 Code. calculation indicates compliance with the Florida Energy Code. o+u, °w •.:: J, °, PREPA D Y: Before construction is completed r DATE: ( this building will be Inspected for compliance with Section 553.908 • ° e I hereby certify that this building, as designed, is in compliance. Florida Statutes. with the Florida Energy Code. COD we L¢� OWNERIAGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed In accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 2/11/2019 3:59 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 4 FARM R4n5-9n17 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: ANISOM ADDITION User 1 Single-family Addition Bedrooms: 0 Conditioned Area: 248 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: Whole House Fan: Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: 9221 WENTWORTH W County: St. Lucia City, State, Zip: PORT ST. LUCIE , FL, CLIMATE _ / V Design Location Design Tamp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH_MUNI 39 90 70 75 299 62 LOW BLOCKS Number Name Area Volume 1 Blockt 248 19114 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 248 1984 Yes 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 66 It 0 248 IF 0 0 1 ROOF _ / V # Type Roof Gable Roof Materials Area Area Color Solar SA Emitt Emitt Deck Pitch Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 269 fN 0 ft' Medium 0.6 No 0.9 No 0 22.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 248 fY N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Free Truss Type 1 Under Attic (Vented) Main 19 Blown 248 IF 0.11 Wood 2/11/2019 3:59 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 4 Cncnn Dent-,�n17 INIPI IT Al IMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Are, Sheathing RA/Ahie.Framing Solar Below _ 1 BE 2 NE Exterior Concrete Block - Ext Insul Main 4.0999 13 8 104.0 ft' 0 0 0.6 Exterior Concrete Block- Ext Insul Main 4.0999 19 8 152.0 ft' 0 0 0.6 0 0 WINDOWS Orientation shown Is the entered. Proposed orientation. / U # Wall Omt ID Frame Panes Overhang NFRC U-Factor SHGC Imp- Area Depth Separation Int Shade .Screening - _ 1 2 BE 1 Metal Low-E Single SE 1 Metal Low-E Single Yes 0.65 0.25 N 20.0 ft• 2 ft 0 in 1 ft 4 in Drapes/blinds Yes 0.65 0.25 N 20.0 ft2 ft 0 in 1 ft 4 in Drapes/blinds None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 231.5 12.71 23.9 .2578 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip HeaUSupplemen None COPA 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/Supplemental for None SEER 14 46 kBtu/hr 1380 cfm 0.85 1 sys#1 SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector Storage System Model # Collector Model # Area Volume FEF fN DUCTS / V # — Supply — Location R-Value Area — Return — Air CFM 25 CFM25 Location. Area. Leakage Type Handler TOT OUT ON RLF HVAC # Heat Cool 1 Attic 6 49 ft' Attic 12 ft' Default Leakage Main (Default) .(Default) 1 1 2/11/2019 3:59 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 4 IL he O 000 cow mom N Om mA my rr gm mm mm mm am mm mm mm ZZ0 mr AA mm mm $C Is mn nn �� wo g c '3 0Mv 00 n N m Om mA mm nr mm mm mm mm mum wow nn rr mm mm mm mm $ .0 MMM ILL 2 o mm An mm rn mm mm mm mm .E E E m z ii C A 6 E 0 <.i O) C R' i 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: ANISOM ADDITION Builder Name: Street: 9221 WENTWORTH WAY Permit Office: City, State, Zip: PORT ST. LUCIE , FL, Permit Number. x w Owner. Jurisdiction: _ Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable Insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints In the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation In any dropped ceiling/soffit Ceiling/attic the Insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors I skylights and framing shall be sealed. Rim joists Rim joists shall Include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation, maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth In unvented crawl spaces shall be covered with Where provided Instead of floor insulation, Insulation ' a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities - cavities shall be filled by Insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt Insulation shall becut neatly to fit around wiring and plumbing In exterior wags, or insulation that on Installation readily conforms to available space shall Shower/tub The air barrier Installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be Insulated. ElectdcaUphone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. In atldit on, Inspection of log walls shall ba In accordance with the prows ons oT ICC-400. 2111/2019 3:59 PM EnergyGauge® USA FBC 6lh Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX" = 96 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. Addition 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 0 13. Cooling system: Capacity46.0 a) Split system SEER 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 248 d) Room unit/PTAC EER e) Other 14.0 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 14. Heating system: Capacity34.0 c) Area 7c. 40.0 a) Split system heat pump HSPF b) Single package heat pump HSPF B. Skylights c) Electric resistance COP 1.0 a) U-facton(welghted average) Be. NA d) Gas furnace, natural gas AFUE b) Soler Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10M e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 1OA2. 4.1 0 Heat recovery unit HeatReC% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans Yes a) Under attic 11a. 19.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit 0 Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final Inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Address of New Home: 9221 WENTWORTH WAY City/FL Zip: PORT ST. LUCIE, FL 2/11/2019 3:69:39 PM EnergyGaugeO USA 6.0.02 - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 1 of 1