HomeMy WebLinkAboutPLANSGeneral Notes A. CONCRETE & FOUNDATION DESIGN: I. ALL CONCRETE GRADE BEAMS AND FOOTINGS SHALL BE 3000 PSI MINIMUM. 2. ALL CONCRETE FILLED SUPPORTED SLABS SHALL BE 2500 PSI MINIMUM, 3 1/2" NOMINAL THICKNESS. 3. FIBERMBSH (3/4" PER CUBIC YARD MIN.) MEETING APPROPRIATE ACI AND ASIM REQUIREMENTS MAY BE USED IN LIEU OF WELDED WIRE MESH 4. ALL SLABS ON GRADE SHALL BE 4" THICK WITH FIBERMESH. 5. ALL REINFORCING SHALL CONFORM TO ASTM A615, BE GRADE 60 (60 KSI MIN.) DEFORMED BARS, #3 BARS MAY BE GRADE 40 6. ALL OVER POUR CONCRETE FILLED SUPPORTED SLABS SHALL BE 3000 PSI MIN., 2" MINIMUM. THICKNESS. 7. SOIL BEARING PRESSURE. SHALL BE A MIINIMUM OF 1500 PSF.. 8. TTiE CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING: OTC (PORTLAND CEMENT TYPE 1,- ASTM C 150). AGGREGATES - #6 STONE, ASTM C 33 SIZE NO. 67 LESS THAN 3/4". AIR ENTRAINING +i-1%- ASTM C 260. WATER REDUCING AGENT - ASTM C 494. CLEANPOTABLE WATER OTHER ADMIXTURES SHALL NOT BE PERMITTED. 9. METAL WELDED WIRE SHALL CONFORM TO ASTM A 185. 10. PREPARE & PLACE CONCRETE ACCORDING TO AMERICAN CONCRETE INSTITUTE MANUAL STANDARD PRACTICE, PART 1, 2, & 3 ALONG WITH HOT WEATHER CONDITIONS RECOMMENDATIONS. I I. IF UTILIZING EXISTING CONCRETE FOR FOUNDATION, CONCRETE SHALL BE A MINIMUM OF 4" IN THICKNESS, VISIBLY FREE OF ANY STRUCTURAL EXCESSIVE CRACKING, SPALLING OR OTHER DETERIORATION. B. MASONRY: (.CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMLM BASED ON TYPE M OR S MORTAR. 2-AIL MORTAR SHALL BE OF TYPE M OR S. TALL GROUT SHALL BE 2000 PSI MINRvfUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 4.PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS Y-0" IN HEIGHT. C. ALUMINUM: I. ALL STRUCTURAL ALUMINUM SHALL CONFORM( TO THE MINIMUM REQUIREMENTS OF 6005-T5 FOR ALLOY WITH A MINIMUM THICKNESS OF 0,040" FOR SUPPORTING MEMBERS. 2. WHERE KICK PLATES ARE USED A MINIMUM THICKNESS OF 0.024" SHALL APPLY. 3. STRUCTURAL ALUMINUM DESIGN CONFORMS TO "PART 1-A - SPECIFICATIONS FOR ALUMINUM STRUCTURES - ALLOWABLE STRESS DESIGN' OR "PART 1-13 - SPECIFICATIONS FOR ALUMINUM STRUCTURES - BUILDING LOAD AND RESISTANCE FACTOR DESIGN' OF THE ALUMINUM DESIGN MANUAL PREPARED BY THE ALUMINUM ASSOCIATION, INC.WASHINGTON D.C. THE FLORIDA BUILDING CODE 6rh EDITION ( CHAPTER 16 STRUCTURAL DESIGN & CHAPTER 20 ALUMINL MO. 4. WHERE ALUMINUM COMES INTO CONTACT WITH STEEL, OR PRESSURE TREATED LUMBER PROVIDE DIELECTRIC SEPARATION. 5. ALUMINUM MEMBERS SHALL BE STITCHED WITH NO LESS THAN 910 SMS 6" FROM THE ENDS AND 12" ON CENTER IF USING #12 SPACING MAY BE 24" ON CENTER. 6. VINYL AND ACRYLIC PANELS SHALL BE REMOVABLE. THEY SHALL BE IDENTIFIED WITH A DECAL ESSENTIALLY STATING "REMOVABLE PANEL SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 M PIP . DECAL SHALL BE PLACED SO IT IS VISIBLE WHEN PANEL IS INSTALLED. 7. 1"X2"X0.045" NONSTRUCTURAL MEMBERS SHALL BE ATTACHED TO HOST WITH 1/4"0 X 1-3/4" EMBEDMENT & 24" O.C. MASONRY SCREW FOR CONCRETE &EQUIVALENT SIZE WOOD SCREW WHEN IN WOOD & #10X 1/2" EMBEDMENT SMLS OR TEK SCREWS IN ALUMINUM MEMBERS TYPICAL. D. FASTENERS; 1. ALL LAG BOLTS SHALL CONFORM TO STAINLESS STEEL TYPE 30018-8, WITH STANDARD FLAT WASHER UNLESS MANUFACTURER GALVANIZES BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD. 2. HEX BOLTS HAS Iv n6 ASTM A 325, PLATED WITH STANDARD FLAT WASHERS AND NUTS. 3. ALL CONCRETE SCREWS SHALL BE, SBMIPSON, 111111, RAWL, TAPCON,REDHEAD, DYNABOLT, PORTECT OR APPROVED EQUAL. 4. ALL METAL TIES AND ASSOCIATED ACCESSORIES SHALL BE HOT DIPPED GALVANIZED. 5. ALL LAG BOLTS SHALL HAVE A MINIMUM EMBEDMENT OF 8X BOLT DIAMETER INTO STRUCTURAL FRAMING (G=.42 MIN.). 6. LAG BOLTS AND SCREWS INTO WOOD FRAMING SHALL BE PROVIDED WITH PILOT HOLES HAVING A DIAMETER NOT GREATER THAN 70 PERCENT OF THE THREAD DIAMETER OF THE BOLT OR SCREW. ALL LAG BOLTS AND SCREWS SHALL BE INSERTED IN PILOT HOLES BY TURNING AND UNDER NO CIRCUMSTANCES BY DRMNG WITH A HAMMER ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. 2. IF ENCLOSURE CONTAINS A SWMB41NG POOL OR SPA, THE ENCLOSURE SHALL COMPLY WITH RESIDENTIAL SWIMMING BARRIER REQUIREMENTS OF THE FLORIDA BUILDING CODE 6th EDITION R 4501.17 IN ITS ENTIRETY, 3. DOOR LOCATIONS MAY BE DETERMINED IN THE FIELD BY CONTRACTOR. 4. IF PAVERS ARE UNDER ALUMINUM MEMBERS THEY SHALL HAVE EPDXY ADHESIVE TO CONCRETE OR IF USING GROUT, ENSURE BONDING AGENT IS USED FIRST. 5. SCREENING MATERIAL SHALL BE 18X14X0.0130R EQUIVALENT DENSITY SCREEN MESH ONLY UNLESS NOTED ON DRAWING S-2. 7E CING S S� BUILDING DIVISION REVIEWED FORCOMPUA E MUST BE KEPT ON J04OR NO INSPECTION WILL BE AI 6. PLEASE NO : 2x2 (typ) DIAGONAL BRA HALL BE FILL -M T. ALL EXPANSION ANCHORS SHALL M DESIGNED IN 2"X2"X0.055"MATERIAL, UNI.ESS OTHERMSE.NOTED ON 5-2.ACCORDANCE WITH THE SPECIFIC MANUFACTURER'S REQUIREMENTS AND ALLOWABLE LOADS AND SHALL ONLY BE APPLIED IN CONDITIONS ACCEPTABLE TO MANUFACTURER. FASTENERS SHALL BE A MINIMUM OF SAE GRADE 95 OR BETTER ZINC PLATED. 8. ALL FASTENERS CONNECTING ALUMINUM COMPONENTS OR PRESSURE TREATED LUMBER ARE STAINLESS STEEL TYPE 300 18-8, UNLESS MANUFACTURER GALVANIZED BOLTS SPECIFIES DESIGN DATA: FOR USE WITH ACQ PRESSURE TREATED WOOD, OR 1. ULTIMATE DESIGN WIND SPEED Vulq (3 SEC ND GUST): 150 MPI3 OTHERWISE NOTED ON PLANS. NOMINAL DESIGN WIND SPEED Vnd: 116 MPH 9. ALL FASTENERS SHALL COMPLY WITH ASTM A153. 2. RISK CATEGORY: 1 10. ALL CONNECTORS SHALL COMPLY WITH ASTM A653 3. WIND EXPOSURE: C CLASS G-185. 4. WIND LOADS: I I. FOR SMS, THE MINIMUM CENTER -TO -CENTER SPACING SCREEN ROOF: 12 PSF SHALL BE 3/4" AND MINIMUM CENTER -TO -EDGE SHALL BE 1/2" SCREEN WALLS: 43 PSF UNLESS NOTED OTHER WISE. SOLID ROOF (SCREEN WALL): N/A COMPONENTS AND CLADDING LOAD. NIA E. REFERENCE STANDARDS: ASTM E 119 ASTM E 1300 CURRENT ASCE 7 CURRENT ALUMINUM DESIGN MANUAL -AA ASM35, AND SPEC. FOR ALUMINUM PART 1-A, & I-B ASTM C94 ASTM C150 ASTM C33 ASTM C260 ASTM C494 ASTM A615 ASTM A185 FLORIDA BUILDING CODE 611, EDITION (CHAPTERS 16.20 & 23). F.ABBREVIATIONS: THE FOLLOWING LIST OF ABBREVIATIONS IS NOT INTENDED TO REPRESENT ALL THOSE USED ON THESE DRAWINGS, BUT TO SUPPLEMENT THE MORE COMMON ABBREVIATIONS. I. TYP--TYPICAL 2. SRO --SIMILAR 3. UON - UNLESS OTHERWISE NOTED 4. CONT-CONTINUOUS 5. VIF-VERIFY IN FIELD G. RESPONSIBILITY: I. ALL SITE WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDINANCES, ETC. 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND DETAILS, NOTIFYING ENGINEER OF ANY DISCREPANCIES BETWEEN DRAWINGS, FABRICATED ITEMS OR ACTUAL FIELD CONDITIONS. 3. THESE DRAWINGS REPRESENT THE ACCEPTABILITY OF THE 'SUNROOM ROOM ADDITION ELEMENTS AS PROVIDED BY THE CONTRACTOR. 4. ALL DETAILS ON THESE DRAWINGS ARE ENGINEERED BASED ON INFORMATION PROVIDED BY THE CONTRACTOR AND MANUFACTURER 5. ANY DETAILS NOT SHOWN ARE TO BE ENGINEERED BY A LICENSED P.E. IN ACCORDANCE WITH STANDARD ENGINEERING PRACTICES. IL MISCELLANEOUS: 1. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE -FAH HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPARATE 4TH WALL SUPPORT SYSTEM MUST BE ENGINEERED SO THAT NO S. THIS STRUCTURE COMPLIES WITH FBCE. 1103.2 AND THEREFORE HAS NO ADVERSE AFFECT ON THE EXISTING STRUCTURE. 6. FACTOR APPLIED TO SCREEN WIND LOADS FOR 18X14XO.013 OR EQUIVALENT DENSITY SCREEN MESH: 0.88 7. FACTOR APPLIED TO SCREEN WIND LOADS FOR ALLOWABLE STRESS DESIGN: 0.6 S. LIVE LOAD: 3001b. VERTICAL DOWNLOAD ON PRIMARY SCREEN ENCLOSURE MEMBERS. 2001b. VERTICAL DOWNLOAD ON SCREEN ENCLOSURE PURLINS. S. EXISTING SLAB AND OR FOOTING BY OTHERS MEETS THE REQUIREMENTS TO RESIST THE UPLOADS FOR THE PROPOSED STRUCTURE. 9. SCREEN ROOF TYPE: I2MANSARD-TRNAVERSF. GABLE 10. SOLIDROOFTYPE: N/A ALUMINUM STRUCTURAL MEMBERS HOLLOW SECTIONS 2 x 2----------------------------------------2" x 2" x 0,044„ 2 x 3----------------------------------------2" x 3" x 0.050„ 2 x 4----------------------------------------2" x 4" x 0.050„ 2 x 5:--------------------------------- ------ 2" x 5" x 0.050" 3 x 3:---------------------------------------3„ x 3" x 0.125" OPEN BACK SECTIONS 1 x 2----------------------------------------- 1„x 2" x 0.040„ 1 x 3:--------------------------- '............ 1" x 3" x 0.045" SNAP SECTIONS 2 x 2 SMSr---------------------------------2" x 2" x 0.045" 2 x 3 SMS- --------------------------------- 2" x 3" x 0.072" 2 x 4 SMS:--------------------------------- 2" x 4" x 0.045" 3 x 3 SMS---------------------------------- 3" x 3" x 0.090" SELF MATING (SMB 2 x 4 SMB----------------------- 2" x 4" x 0.044" x 0.100" 2 x 5 SMB----------------------- 2" x 5" x 0.050" x 0.118" 2 x 6 SMB--------------------- 2" x 6" x 0.050" x 0.120" 2 x 7 SMB----------------------- 2" x 7" x 0.057" x 0.120" 2 x 8 SMB----------------------- 2" x 8" x 0.072" x 0.224" 2 x 9 SMB----------------------- 2" x 9" x 0.072" x 0.224" 2 x 10 SMB:------------------- 2" x 10" x 0.092" x 0.374" TUBE SECTIONS 2 x 2--------------------------------------2" x 2" x 0.090" TFIESE PLANS AND ALI. PROPOSED WON A; I: SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECT ORS TIVVf MAY BE NECESSARY IN ORDER TO COhPPLY VJITH ALL APPLICABLE CODES. CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBU Y OF THE CONTRACTOR OF RECORD RECEIVED MAR 01 2019 ST. Lucie County, Permitting -,� 19oz_()zSD 16, v "•`•L1C ENS No. 706E m ti? ems, ®, STATE OF 0. '•c� O R ID ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P. FLORIDA LICENSE: 38654 Mark R. Dunn P.E. FLORIDA LICENSE: 73968 'Joel Falardeau P.E. fLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans & Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph# (813)788.5314 Fax# 1-(866)824-7894 E-mail-erb@fbcplans.com W ebs ite-www. fbcplan s.com C.O.A. #29054 DATE: 2/8/2019 DRAWN BY: TLK 1 REVISION: I DATE: 1 R 1 2/28/20192 SCANNED3 4 Job# 19 0130 148 PROJECT ADDRESS: 0 BELFRY PL 'T ST. LUCIE, FL 34986 K & S INDUSTRIES, INC. 1379 SW BILTMORE ST. PORT ST LUCIE, FL 34983 NOTES S-1 THIS COMMENT SHALL NOT BE REPRODUCED IN WHOLE PERMISSION OF TRAC DESIGN, O tx2 I S-4 I N x N I I 2X7SMB o> > > I I X X X N t14 2X7SM8 N N )A o I I I ` 2X7SMB I b zI I N N N c 2X6SMS n aa N N N 2X6SMB' N tV 2X2 t 2X2 t 2X6SMB U> * 04 x S-3 m X X X N 2X2 t 2X2 N 2X6SMb' N N M L!24 InAxn xN N 2X2 t 2X2 t 2X6SM8 ti S-3 N N N N N N 22'-0" N -�� 2X2 t \� 1x3_ 1 ` I �T 2X2 � � 2X2 t 2X2 t 2X2 T000 m � M M M '� i0 M 01 0�0 r- n N r/CX4 iC N N N N N N I O 2X2 t 2X2 t 2X2 t 2x2 t C 0 I ,•yri S-4 kLyp) � S-4 S-4 I I I I I I I I I I I I I I CN I Ix I I I I I I I I I --I-- I I I I I I I I we] 0 0 I O I ENGINEER OF RECORD: David W, Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P. FLORIDA LICENSE: 38654 Mark R. Dunn P.E. FLORIDA LICENSE: 73968 Joel Falardeau P.E. FLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans & Engineering Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Fh# (813)788-5314 Fax# 1-(866)824.7894 E-mail-erb@fbcplans.com W ebsite-www,fbcplans.com C.O.A.429054 DATE: 2/8/2019 DRAWN BY: TLK i I REVISION: I DATE: RO1 2/28/2019 RO 2 RO 3 RO 4 Job# 190130148 PROJECT ADDRESS: BARRETT 8410 BBLFRY PL PORT ST. LUCIE, FL 34986 ]ONTRACTOR: K & S INDUSTRIES, INC. 1379 SW BILTMORE ST. PORT ST LUCIE, FL 34983 FLOOR PLAN S-2 IN PARTWITHOUT 1" XS" OR 7"X6" WIDTH EXTRUDED GUTTER BRACKET(THICKNESS OF LEG@ LAG SCREW SHALL BE 0.125" MIN. LONG LEG SHALL BE 0.072" MI @ EACH BEAM W/ (4) #l0X3/4" SMS 1" SPA. 1" x 2° x 0.045" OPEN BACK INTOGU17ERLIP W/(2)#14X2-I/2°@ TANGLE & (1)#12X2-1/2" @ 24" O.C. (SLOPED OR \ _ HORIZONTAL) O i \ 00 \ 0 \ 6 -- \ eO 2"x2"x 1 X \ ALUMINU/8" M ANGLE w/ (4) #14 z 3/4" x 2" x 0,045" OPEN BACK SMS INTO PURLIN 0 W/ (2)#14X 2-1/2" @ EA SIDE & IGLE&(1)#12X 2-1/2"@ 24" O.C. SUPER GUTTER _ (5"&7") 2^x "SMB X(MIN) (SEE SHEET S-2 RECEIVING CHANNEL ]I � FOR SIZE] (4) #10 X 3/4" SMS (TYP EACH SIDE) (8) #10 X3/4" SMS (INTO GUTTER) UPRIGHT SEE SHEET S-2 FOR SIZE Al GUTTER CARRIER BEAM & BEAM ATTACHMENT DETAIL S 3 N.T.S. 0FrIONAL PZ-BRAECKET0.250" 5" OR 7"X 6" WIDTH X 0.250" EXTRUDED GUTTER BRACKET @ EA BEAM W/ (4) #12 X 3/4" SMS INTO GUTTER LIP 1" x 2"x 0.045" OPEN NOTE: 2X4 SMB BEAM ONLY REQUIRES 4" WIDTH GUTTER BRACKET W/ (2) 3/8" LAGS (4) 3/8" LAG SCREWS @ 1-1/2" SPACING @ EA. GUTTER BRACKET & @ 12" O.C. MAX- MIN EMBEDMENT SHALL BE 2" UPRIGHT WEB LAPPED OVER PURLIN W/(2)#12X3/4"SMS EACH SIDE THRU UPRIGHT& PURLIN HACK W/ (4)#14X 1-1/2" 2"X2"MEMBER ATTACHED TO - INTO GUTTER &(1)#14X�j — �. UPRIGHTW/(3)#10XI-1/2"SMS 1-1/2° @ 24" O.C. 1 INTO SCREW BOSS 1"XTWO.045" OPEN BACK _I )/ ATTACHED TO PURLIN W/ 00 BEAM ,/1\ #SOX1-1/2" SMS INTO SCREW LBOSS 2"x2"x%"XALUMINUM7#1U2 THE HOST STRUCTURE SHALL ANGLEw/ (4) #14 x3/4°HAVE AT LEASTA 2"X4" SMS INTO BEAM ON EA SIDE FASCIA AND ROOF TRUSS EA. LEG SYSTEM. CONTRACTOR SHALL THIS AND 1F 2"X2"XO.062" RECEIVING[VERIFY MS SMALLER -CONTRACTOR CHANNEL W/(2)#lOX 3/4° SIDE SHALL BRING STRUCTURE UP RA SIDE TO COVER EXPOSED TO A 2"X4" FASCIAAND BEAM ENSURE LESS THAN A 2'-0" /� OVERHANG. N \ GUTTER BRACE & BEAM ATTACHMENT DETAIL S-3 N.T.S. 1"X2°XO.045" OPEN BACK ATTACHED TO 2M'XO.045' SAVE RAIL MEMBER• 91OXI-1/2"SMS @ 24" O.0 POST C^� SLOPED OR FLAT PURLIN UPRIGHT LAP DETAIL S J SCALE:NTS BEAM SCREWS 2"X4"SMB 6 2"X5"SMB 6 2°X6"SMB 8 2"X7"SMB 8 2"XB"SMB 10 2"X9"SMB 10 2"X 10"SMB 12 HINGE LOCATION BEAM / #lO 2 () X3" SMS CROSS FOR SLOPED BEAMS, / SCREWING BRACE TO BEAM OR 2" x 2" EXTRUSION MAINTAIN ALL SCREW SPACING i EAVE MEMBER (.125" BACKING PLATE USED) 2" x 2" EXTRUSION FROM EDGE OF BEAM i'SELF-MATING BEAM SHALL BE NOTCHED I HINGELOCATION DOOR 2"x2"EAVE RAIL SECTION 5 FORUPRIGHT — (UNLESS OTHERWISE SHOWN ON S-2)ROOF �� - ATTACHED TO BEAM w/ BRACE (3)IOX 2" SMS INTO SCREW II "a EAVE RAIL I EAVE �il� / 1"X2"OPEN BACK RAILATTACHED TO oil i (1)3/8"0 THRU I / / HINGELOCATION UPRIGHTw/(2 #10 x 1 �' SMS INTO SCREW I / BOLT W/ NYLON LOCKING BNUT OLT W/ NYLON 2"x"2"x.125" FLAT BOSS LOCKING / BAR (typ) 2'NOTCH OF INSIDE BEAM MATERIALAPPLIED I : / #30 X 1°SMS 24" C/ TO SLIDE OVER UPRIGHT — _ NOTES: #14X 3/4° SCREWS 1. HINGES SHALL BE ATTACHED TO STRUCTURE W/ (3) #10 x 5/8" SMS MINIMUM. (SEE TABLE ABOVE) — — — 2. DOOR SHALL BE ATTACHED TO ENCLOSURE w/(2) HINGES MINIMUM. 4" (MIN) UPRIGHT 3. HINGES SHALL BE ATTACHED TO DOOR WITH (3)#10 x 5/8" SMS. FASTEN A 1" x 2" x 0.044" TO UPRIGHT W/#12 x 1" SMS @ 12" O.C. AND WITHIN 3" FROM END OF THE UPRIGHT, ROOF BRACING CONNECTION DETAIL F D s"-'3 SCALE: N.T.S. TYPICAL SCREEN DOOR CONNECTION DETAIL UPRIGHT TO BEAMCONNECTION -ALL WIND ZONES S-3 SCALE:NTS S-3 SCALE: NTS ®1II.III ®'?A� J o No.38W a ^ FC g u® m 1l TE C F �v�® -0fBMON pls� ENGINEER OF RECORD: David W, Smith P.E. FLORIDA LICENSE: 5360E Thomas L. Hanson P. FLORIDA LICENSE: 38654 Mark R. Dunn P.E. FLORIDA LICENSE: 73968 Joel Falardeau P.E. FLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans & Engineerir Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph# (813)788-5314 Fax# 1-(866)824.7894 E-mail-erb @ fbcplans.corn W ebsite"Www.tbcplans.com C.O.A. #29054 IDATE: 2/8/2019 DRAWN BY: TLK REVISION: DATCP(IVIVEII RO 1 RO 2 RO 3 RO 4 .-0 IF 1=! 410 BI<LFRY PL ORT ST. LUCIE, FL 34986 "'ONTRACTOR: K & S INDUSTRIES, INC. 1379 SW BILTMORE ST. PORT ST LUCIE, FL 34983 DETAILS S-3 SHALL NOT BE REPRODUCED IN WHOLE DESIGN, OPTIONAL 5"OR 7°-X 0.250" EXTRUDED GUTTER Z-BRACKETO.250" BRACKET 2° GUTTER BRACKET REQUIRED AT PURLINATTACHMENT POINTS w/ (2) 912 X 3/4" SMS INTO GUTTER LIP 1"x2"x0.045"OPEN BACK W/f2)#14X O.C. OR OPTIONAL 2"X2"XO.045" PURLIN N 2"x 2°x%"XALUMINUM ANGLEw/ (4) #12 x3/4" SMSINTO PURLIN ON EA LAG SCREWS @ EA GUTTER f & (1) @ 12' O.C. MAX- MIN ENTSHALLBE2" THE HOST STRUCTURE SHALL HAVE AT LEAST A 2' X4" FASCIA AND ROOF TRUSS SYSTEM. CONTRACTOR SHALL VERIFY THIS AND IF & (4)12X3-1/2" INTO —SMALLER- CONTRACTOR GUTTER SHALL BRING STRUCTURE UP TO A 2"X4° FASCIA AND ENSURE LESS THAN A T-O" OVERHANG. Al GUTTER BRACKET& PURLIN ATTACHMENT DETAIL S'4 N.T.S. OPTION #1 (4) #10 X 3/4" SMS FASTENING SECOND�A.�R,YyANGLE TO COLUMN C"EACH SIDE) -UPRIGHT SECONDARY ANGLE MIN 0.125° THICK (NOT REQUIRED FOR 2X3 '2"X2" ANGLE (2) #10 X 3/4" SMS FASTENING (B) - CONCRETE SCR4TABLL, ANCHOR INTO SECONDCOLUMN TO PRIMARY ANGLE OPTION#2 ANGLE(TYP EACH SIDEABOW EACH SIDE)TAB1"X2"BASE MEMBER (TYP EACH SIDE) ANCHOR(1)- CONCRETE SCREW (SEE (MIN)(TYP)(SETABLE ANcBo 2"X2"OR 2"X3"_j LI BEAM .062"ALUMINUM INTERNAL OR MEMBER XTERNAL RECEIVING CHANNEL / (4) #10 X3/4" INTO INTO OR UPRIGHT. (2) #14X 3/4" EA LEG INTO GIRT OR PURLIN- (0.062"ANGLE CLIPS w/(2) #14x3/4° SMS EA LEG) UPRIGHTOR BEAM -SNAP OR SELF MATING OR HOLLOW H PURLIN OR GIRT TO BEAM OR POST DETAIL S'4 SCALs: NTS Column Size 1/4"& 3/B" 0 Concrete Screw Anchor B IMin.Spa 4 4- 4 4 6-U24. -ZTTT8 OPTION #1-A-36 STEEL CLIP MAY BY PLACED ON DOUBLE COMPRESSION 5° TOP ORSIDEOFDECKW/ SLEEVES (2) 3/8°X3" SLEEVE TOPOF ANC-UOR 4"NOMIMALSLAB CONCRETE MINIMUM d d 4 d' v 4 3/8" 0 x 3" MASONRY 2500 PSI CONCRETE W/ ANCHOR (MIN 3-3/4" OPTION#1 WELDEDWIREOR EMBEDMENT) (4* 'LAB ONLY) FIBERMESH L125"STAINLESS STEELCABLE 250OPSICONCRETEW/ W TOP OF ELDED WIRE OR r_.__...._.... oI 4"NOMINALSLAB d . ' MINIMUMo d 4 ' • d 1-1/2'XS-1/2"ALUMINUM OPTIONO2 STRAP W/ (2) 3/8 "0 X3" (use WITH FOOTING) MASONRYANCHOR (MIN 3-3/4" BEDMENT) J1 _ CABLE TO FOUNDATION CONNECTION DETAIL SCALE: NTS ) PRIMARY ANGLE AND C& 1/4" 0 CONCRETE 3" (MIN) SCREWANCHOR@ 24"O.C. BETWEEN COLUMNS NOTES; (7YP EACH SIDE) 1. NUMBER OF ANCHORS"B" IS EACH SIDE INTO THE SECONDARY ANGLE AND DOES NOT INCLUDE THE ANCHOR INTO THE 1(2. 2. MINIMUM EMBEDMENT OF ANCHORS INTO CONCRETE FOOTING SHALL BE 2-3/4" ATATALL UPRIGHTLOCATIONS. ALL SCREW LENGTHS AT UPRIGHT CONNECTIONS SHALL BE OF SUFFICIENT LENGTH FOR REQUIRED EMBEDMENT INTO CONCRETE FOOTING WHEN A PAVER DECKIS PRESENT. 3. CONCRETE SCREIV ANCHOR DESIGNSARE BASED ON THOSE LISTEI ON S-1, D,FASTENERS, OTHER BRAND& TYPE SHALL BE APPROVED BY ENGINEER. 4.2X3W/1X2 CORNER POST SHALL REQUIRE SAME BASE CONNECTIONS AS 2X4 SHOWN IN TABLE. 2"x3" OR LARGER UPRIGHT TO CONCRETE W/WO PAVER DETAILS SCALE:NTS NOTE: WHEN USING OPTION #2 CONNECTION CABLE MUST BE WITHIN 6" OF CORNER OR PRIMARY MEMBER. 1"X 2" X 1/8" ANGLE —10 (4) #12 X 3/4" SMS 0 • (1YP TOP AND SIDE) e wo• DIA. STAINLESS :L CABLE WELDED STAINLESS L EYE BOLT (8) #14 X3/4 S. m °4 4�`I�Defineemp \C E N m s � ;1 DYSATE OF !" �P! m'aE0.9efeE "�g+y9Epe?� ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P FLORIDA LICENSE: 38654 Mark R. Dunn P.E. FLORIDA LICENSE: 73968 Joel Falardeau P.E. FLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans & Engineering Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph# (813)788-5314 Fax# 1-(866)824.7894 E-mail-erb @fbcplans.com W ebsite-www.fbcplans.com C.O.A. #29054 1/8"ALUMINUM PLATE@45° DATE: 2 8 2019 ANGLE W/ 1" ° `BREAK �0 9°- w/ DRAWN BY: TLK 5/16" EYE BOLT W/LOCK NUT& REVISION: DATE: WASHER EA SID (9)#14X 3/4SM RO1 @i" O.C. RO 2 RO 3 OPTION #3 RO4 WASHER BENEATH NUT — I3�df R-1�4NDDRESS: BENEATH � i � e • — BARRETT • • 8410 BELFRY PL --- PORT ST. LUCIE, FL 34986 I' 3/8° 0 ADJUSTABLE EYE Top View • �I BOLT FOR CABLE TENSION OPTION #2 . • 1/8"OSTAINLESS STEEL CABLE I PERIMETER FRAMIN 2"X2"X1/8"EXTRUDED ANGLE ON 45°ANGLE Side View OPTION #1 J2 CABLE CONNECTION AT CORNER S'_Ll SCALE;NTS "IONTRACTOR: K & S INDUSTRIES, INC. 1379 SW BILTMORE ST. PORT ST LUCIE, FL 34983 DETAILS S-4 THIS DOCUMENT SHALL NOT BE REPRODUCED IN TRAC DESIGN. LLC