Loading...
HomeMy WebLinkAboutENGINEERING AND TESTING INC PAPERWORKENGINEERING & TESTING, INC. Phone: (866) 781-6889 *Fax: (866) 784-8550 www.fIoridaenginceringandtesting.com 250 S.W.13'h Avenue Pompano Beach, FL 33069 DATE: 2/12/19 JOB ORDER 9: 19-796 CLIENT: All Area Roofing ADDRESS: 3921 S. US Highway 1 Fort Pierce, FL 34982 PROJECT: Ward Residence Flat Wood Non -Insulated Roof Deck ADDRESS: 6014 Bamboo Drive Fort Pierce, FL SCANNED 2017 FBC/ASCE-7 DESIGN PRESSURE CALCULATIONS BY Lu e County Proiect Information: Height = 9' Exposure: C Basic/Ultimate Wind Speed: V if=160 mph Length= 50' Category: lI Nominal Wind Speed: V,d=V is*40.6 Width = 34' Slope: < 7° (asd = allowable strength design) Parapet Wall: N/A Residential Kz = 0.85, Kzt =1.0, Kd = 0.85 Design Calculations: Velocity Pressure: q = 0.00256*KXnKdW Velocity Pressure (it): q=0.00256(0.85)(1.0)(0.85)(160)2 = 47.35 psf Velocity Pressure (.d): q=0.00256(0.85)(1.0)(0.85)(160*40.6)2 = 28.41 psf Width of Pressure Coefficient: 0.1(34') = 3.4' 0.4(9') = 3.6' ) use: 3'6" Effective Wind Area: <lOfF For parapet height three feet (3') or larger, zone three (3) shall be treated as zone two (2). External Pressure Coefficient: 1) GCP1 = -1.0 2) GCP2 = -1.8 3) GCP3 = -2.8 Internal Pressure Coefficient: 1) GCP; = 0.18 0�,e '�% tr U Q / Quality 4 Ali ✓lssarance 1 - Page 2, 2/12/19, Job OrdL., —9-796 All Area Roofing - Ward Residence Flat Wood Non Insulated Roof Deck 6014 Bamboo Drive; Fort Pierce, FL: Design Pressures Based on Vasd: 1) Field 2) Perimeter 3) Corners Attachment Requirements: P 1 = 28.41 * [(-1.0) — (0.18)] _ -33.5 psf P2 = 28.41 * [(-1.8) — (0.18)] _ -56.3 psf P3 = 28.41 * [(-2.8) — (0.18)] _ -84.7 psf The system is acceptable as approved based on the requirements of Florida Product Approval # FL1654-R23, Appendix 1, page 26 of 65, System No. W-170 with a maximum design pressure of -90 psf. Base Ply: Self adhere one or more plies of Elastoflex SA V Base Ply sheet to the min. 15/32" plywood deck. Cap Ply: Torch apply the Polyflex G Cap Ply sheet to the base ply sheet. Notes: Corners and perimeter area dimension shall not be less than a = 3'6" Contractor to verify that the fastening patterns meet manufacturer's requirements for issuance of a warranty (as applicable). All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and Florida Building Code 2017 Edition. Wind load calculations based on ASCE-7, FBC 2017, and information provided by client. Client is responsible for verifying existing/proposed conditions/decks as it pertains to the above provided product approval. All work shall be inspected by our field engineer (or authorized representative) or a building department inspector to verify compliance with specifications. . _ Sincerely, Mark A. Mesiag Florida Enginee4 Florida Reg. No. Certificate of Au