Polyglass USA, Inc. Evaluation Report P12050.02.09-R24 -
1111 West Newport Center Drive SCANNED FL52S9-R28
Deerfield Beach, FL 33442 BY Date of Issuance: 02/24/2009
(954) 233.1230 St. Lucie County Revision 24: 01/24/2019
SCOPE:
This Evaluation Report is .issued under Rule 61G20.3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 6a' Edition (2017) Florida Building Code sections noted
herein.
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMOIetc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOJetc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection atthe job site at the request of the Building official.
This Evaluation Report consists of pages 1 through 14.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
Thg facsimile seal appearing was authorized by Robert Nieminen,
P.E. an 01/2412018, This does not serve as an electronically
signed document,
CERTIFICATION OF INDEPENDENCE:
1. NEMOIetc. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMOI etc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest;in any company manufacturing or distributing prod cts for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial Interest In any other entity involved in the p Ices of the
product.
5. This is a building code evaluation. Neither NEMOietc. nor Robert Nieminen, P.E. are, in a ySe. i e o Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for P t gn guidance unless retained
specifically for that purpose. �k
ONEMOjetc.
5.5 Allowable Roof Covers:
Foam -On Tile
wood Shakes
Metal R Shingles Slate
Undena yment Asphalt Shingles
Nall -On TJe
Elastobase yes
Yes
(Bate sheetin 2-ply sV+taml
Yes
(Wte ShN[102-Dysyrtem)
Yes
Yes
Yes
Elastobase P yes —
Ves
Shnt in 2.piVSV+teml
- --Yes
(Base Shext in 2-ply stn.)
Yes
Yes
Yes
Potyglass G2 Base No
Yes
(Base shoat In 2-prysVrteml
Yes
lane sheet in 2.plysy[em)
No
No
No
I Potyglass APP Base No
j
Yes
Buesheet in l-ph nY+tem)
Yes
tBte Shetln2-plysy+tem)
No
No
N0
Wystick MTS or MTS PLUS Yes
Yes
No
Yes
Yes
Yes
Polystick lR-Xe _ I Yes
No
No
No
Yes
Yes
�Palystick TUP ' No
Yes
Yes(See S5.1)
No
No
No
P0lys_ NPlus Yes
Yes
Yes (See 5.5.1)
Yes
Yes
Yes
I Polystick TU Max No
Yes
Yes (See 5.5.1)
Yes
No
No
' Polystick Dual Pro - I Yes
No
No
Yes
Yes
Yes
Polystick Tile Pm Ves
Yes
Yes (See5.5.1)
Yes
Yes
Yes
Polystick MU-X Yes
No
No
Yes
Yes
Yes
Elastoflex S6G I Yes I
Yes
Yes (See 5.5.1)
No
Yes
Yes
i Elastoflex S6 G FR Yes
Yes
No
No
Yes
Yes
ElastoRex G TU Yes
Yes
Yes (See5.5.1)
No
Yes I
Yes
PolyflexG Yes
.Yes
Yes (See SSA)
No
Yes
Yes
! Polyflex G FR Yes
Yes
No
No
Ves
Yes
I Palyflex SAP or SAP FR Yes
Yes
Yes (See5.5.1)
No
yes
Yes
Mule-Hitle SA-APP Cap Sheet Yes
or SA-APP Cap She11(FR)
Yes
Yes (See S.5.1)
No
Yes
Yes
_l
5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations.
l z
Adhesive Flodde Product
Undedayments
Approval
DAP Foam Touch'n Seal StormBond Roof
Tile Adhesive
FL14506
Polystick TU Plus, Polystick TU Max
'
Dow TileBond'"
FL22S25
Polystic[ TU P, Polystick TU Plus, Polyflex SAP or Tile Pro
Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro.
ICP Adhesives Polyseta AH-160
FL6332
Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyp" SAP, Polyflex SA Cap FR.
Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro,
ICP Adhesives Polysetp RTA-1
FL6276
Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR,
'
Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
I Refer to Tile Manufacturer's orAdhasfve Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
MEMO ETC, LLC. Evaluation Report P12060.02.09.R24
Cenfcate CfAvthoraotmn u32455 62" EDITION(2027) FBC NON-HVH2 EVALUATION FL5259-R2g
Potyglass Roof Underlayments; 1954) 233-2230 Revision 24: 01/24/2018
Page 5 of 14
NNEMOletc.
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
Polystick (all variations), Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule•Hide SA-APP Cap Sheet or SA-APP Cap Sheet
(FR) self -adhered to:
New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing
plywood; New or existing, unprimed_0$B; ASTM D41 primed OSB; Southern Yellow Pine; ASTM_ D41 primed
Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "21P System" Panels
(designed and installed to meet wind loads for project).
Note. Polyglass does not require priming of new or existing plywood or 0S8 sheathing. New or existing plywood or
0S8 sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes.
Elastoflex G TU, Elastoflex 56 G or Elastaflex S6 G FR in hot asphalt to:
e ASTM D41 primed structural concrete.
Polyflex G or Polyflex G FR torch -applied to:
> ASTM D41 primed structural concrete.
5.6.2 Bond -to -Insulation:
Polystick (all variations), Polyflex, SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered
to:
i ASTM C1289, Type 11, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck
DuraGuard; Dens Deck Prime; or SECUROCK Gypsum -Fiber Roof Board.
Elastoflex G TU, Elastoflex 56 G or Elastoflex 56 G FR in hot asphalt to:
> Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
Polyflex G or Polyflex G FR torch -applied to:
ASTM 041 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile
systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of
the insulation/underlayment system in accordance with FBC Section 1504.3.1.
5.6.3 Bond to Mechanically Attached Base Wver:
Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or
Tile Pro self -adhered to:
ASTM D226, Type 1 or 11 felt; Elastobase; Elastobase P or Mule -Hide Nail Base.
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
ASTM D226, Type I or II felt; Elastobase; Elastobase P, Mule -Hide Nail Base or Polyglass G2 Base.
Polyflex G or Polyflex G FR torch -applied to:
Y Elastobase; Elastobase P, Mule -Hide Nail Base, Polyglass G2 Base or Polyglass APP Base.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed In Section 5.6.4 herein, or as tested in
accordance with FBC Section 1504.3.1.
NEMO ETC, U.C. Evaluation Report P22060.02 09-R24
rengimre ofAutho.w. e32ASS 6" EDITION (2W) FBC NON-HVH2 EVALUATION FLS2S9-R26
Polyalass Roof Underlayments; (954) 233.1230 Revision 24: 01/2412018
Page of 14
ONEW10letc.
5.6.4 Wind Resistance for Llnderlavment Systems in Foam -On Tile Applications: FRSA/TR1 April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment
forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on the applications. Maximum Design Pressure is the
result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure
divided by 2 (the 2 to 1 margin of safety per FBC 15D4.9 has already been applied)_. Refer to FRSA/TRI April 2012 (04-
12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads.
#1 Maximum Design Pressure=-90 osf:
Deck: Min. 15/32-inch plywood to meet project requirementsto satisfaction of Authority Having Jurisdiction.
Primer: None
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. -
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
42 Maximum Design Pressure =-97.5last.
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM 041
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 11 ga. x
1'/." ring shank palls through 32 ga., 1-518' diameter tin caps spaced 12-inch o.c.
#3 : Maximum Design Pressure =-105 PSE
Deck: Min. I5/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: WB-30GO
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP Fit, Mule -Hide SA-APP Gap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x
I%'ring shank nails through 32 ga., 1.5/8" diameter tin caps spaced 12-Inch o.c.
#4 Maximum Design Pressure = -13513
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having jurisdiction.
Primer: (Optional) PG100 or ASTM D41
Base Piy: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#5 Maximum Design Pressure =-315 tuf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Tile Pro, Polyflex SAP, Palyflex SAP FR, Mule -Hide SA-APP Cap
Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#6 Maximum Design Pressure=-622.5 osf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#7 Maximum Design Pressure =-30.0 ps;P;
Deck: Min. 15/32-inch OSS to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-Inch D.C. at the 3-Inch wide side laps and 6-inch D.C. at two (2) equally spaced staggered center rows.
Base Ply: '(Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, PoWex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
MEMO ETC. LLC. Evaluation Report P32060.02.09-R24
Cedlfi eQfAur/ llzermn e324SS 6r"EDITION (2017) FaC NON-HVH2 EVALUATION FL5259-1126
Potygiass Roof Underlayments; (954) 233-1230 Revision 24: OIJ24/2018
Page 7 of 14
NEMOI etC. .
#23 Maximum Design Pressure =-90 psf
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction,
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch-oppfled underloyment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-Inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 9-inch ox. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex SG G, applied in full mopping of hot asphalt or torch=applied-or Polyflex G, torch -
applied.
#24 Maximum Design Pressure=-97.5 osf:
Deck:
Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners:
. 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing:
4-inch o.c. at the 4-inch wide side laps and 4-inch o.c. at fgpr (4) equally spaced staggered center rows.
Base Ply:
(Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#25 Maximum
Design Pressure=-105 Dsf:
Deck:
Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction,
Base Sheet:
Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners:
Simplex MAXX Cap Fasteners
Spacing:
6-inch o.c, at the 2-Inch wide side laps and 6-Inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mapping of hot asphalt or Polyflex G, torch -applied.
#26 Maximum
Design Pressure=-112,5 psf:
Deck:
Min. 19/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners:
11 ga, x 1.25-inch x 3/8-Inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing:
6-inch o.c. at the 4-inch wide side laps and 6-Inch o.c. at four (4) equally spaced staggered center rows.
Primer: -
PG100 or ASTM D41 primer at all tin -caps
Base Ply:
Polystick MTS or Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#27 Maximum
Design Pressure = -120 psf:
_
Deck:
Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction,
Base Sheet:
Elastobase (sanded top surface for hot -asphalt ortarch-applied cap or poly -film surface for torch -applied cap)
Fasteners:
OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3' Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing:
6-inch o.c. at the 4-Inch wide side laps and 6-Inch o.c. at five (5) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#28 Maximum Design Pressure =-120Psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast #12 DP or Trufast #14 HO with Trufast 3" Metal Insulation Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt.
5.6.4.1 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on tile systems carry a Maximum
Design Pressure of -45 psf.
NEMO ETC, LLC Evaluation Report P1206002 09-R24
Certlfiwfe o`Aurnon:oCoa 4324SS 6m EDITION(2017) FSC NON.HVHZ EVALUATION FL5259.82B
Polyglass Roof Undedayments; (954) 253-SS30 Revision 24: 01l24/2018
Page 10 of 14
ONEMOletc.
5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed
that required under FRSA/TRI April 2012 (04.12), Appendix A, Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density
designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are
AN51/SPRI WDS, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked
with -arc asterisk" carry the limitations -set forth in Section 2-.2.10.1 of FM LossPievention Data Sheet 1-29 (January
2016) for Zone 213 enhancements.
5.7 Exposure Limitations:
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days
after installation.
Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-days after installation.
Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Dual Pro, Tile Pro or Elastoflex G TU shall not be left exposed for
longer than 180-days after installation.
Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SXAPP Cap Sheet (FR) does not have an exposure
limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 30
days.
Elastoflex S6 G or Elastoflex S6 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the
prepared roof covering Is to be adhesive -set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum
exposure is 180 days.
5.8 Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226
roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as
set forth in Section 4.3, Note 1 of ASTM D1970-15, should be established as to slip resistance.
5.9 Tile Sliooaee Limitations (FRSA/TRI April 2012 (04 12)1
When loading roof tiles on the underlayment in direct -deck the assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
.
Underiayment Tile Profile
Staging Method
Maximum Slope
Elastoflex G TU Flat
Lugged
10-tile stack
7:12
8-tile stack (6 over 2)
6:12
Elastoflex 56 G or 56 G FR Flat or Lugged
6-tile stack (4 over 2)
4:12
Polystick MT5 or MTS PLUS Flat
Lugged
6-tile stack (4 over 2)
5:12
6-file stack (4 over 2)
4:12
Polystick Tile Pro Flat or lugged
6-tile stack (4 over 2)
7:12
i Flat
Polystick TU Max _ Lugged
Lugged
6-tile stack (4 over 2) or 10-tile stack
7:12
6-tile stack (4 over 2)
7:12
YO-tilestack
6,12
Polystick TU P Flat
Lugged
&tile stack (4 over 2)
6:12 .
6-tile stack (4 over 2)
4,12
Polystick TU Plus Flat or Lugged
Flat or Lugged
6-tile stack (4 over 2)
7:12
10-tile stack
6:12
Ej
Polyflex G or G FR Flat or Lugged
6•tile stack (4 over 2)
4:12
Polyflex SA P or SAP FR Flat or Lugged
:-tile stack 14 over 2)
4:12
YEMO ETC, LLC. Evaluation Report P32060.02.09-R24
t"rrr nztr aJnunc�rizatian 432455 6"'EDIT70N(7017)FBC NON-HVHZ EVALUATION FL5259-08
Polyglass Root Underlayments, (9S4) 233.1230 Revision 14: 01/24/2018
Page 11 of 14
ON EIVIO etc.
6. INSTALLATION:
6.1 PoWlass Roof Underiayments shall be installed in accordance with Polyglass published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application, and prime the substrate (If applicable).
---
y' -Y, XW11IZ
—
6.3.1 Non -Tile Applications:
Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed'.
Elastobase, Elastobase P or Mule -Hide Nail Base may be covered,with a layer of Polystick, Polyflex SAP, Polyflex SA.
P FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered, Elastoflex G TU, Elastoflex S6 G or
Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR, torch applied. Roof cover limitations are those are
those associated with the top -layer underlayment, as set forth in Table 1.
6.3.2 Tile Applications:
Elastobase, Elastobase P or Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the "Two
Ply System" from FRSA/TRI April 2012 (04-12). Reference is made to Table 1 and Section S.6A herein, coupled with
FRSA/TRI April2022 (04-12) Installation Manual.
6.4A Shall be installed In compliance with the codified requirements for ASTM DI
in FBC Table 1507.1.1 for the type of prepared roof covering to be Installed.
6.4.2
Direct -to -Deck with Mechanically Fastened Roof Covers:
All self_adhering materials, with the exception of Polystick TU Pius, Potyfiex SAP or SAP FR and Mule -Hide SA-APP
Cap Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage edge seam in accordance with Polyglass / Mule -
Hide back nailing guidelines. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1-inch
diameter metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back -
nailed using the above noted fasteners and spacing, In area marked "nail area, area para clavar' on the face of
membrane. The head lap membrane is to cover the area being back -nailed.
All seal -lap seams (selvage laps) must be
firmly rolled with a minimum 28 lb. hand
roller to ensure full contact and adhesion.
For Dual Pro .and Tile Pro, align the edge of
the top sheet to the end of the glue pattern
(the sheet will overlap the fabric).
All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified
Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap.
Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys,
or exposed roof to wall details
N£MO ETC, ILC. EvalUation Report P32060.02.09.R24
tertlh'rate ofAalhomotm� A32455 67"EDITION (2027)F9C NON-HVHZ EVALUATION FL5254-R28
PoWlass Roof UMedaymems; (954) 233-t230 Revision 24: D2/24/2018
Page 12 of 14
ONEMOjetc.
Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or
Polyglass PGS00 Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of the
Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be
installed in a water shedding manner.
All Poystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a
minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied
for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min.28111 roller) or small -areas of the
roof that are not accessible to a large roller or broom.
6.4.3 Tile Applications (not allowedforPoWtfckDual Pro, fRXeor➢olvsdckmuX)•
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted above as a guideline.
For mechanically fastened the roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base
Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12),.Table 1.
For adhesive -set tile applications, refer to Section 5.6.4 herein.
6.4.4 lw—oA21—Ply Underiavment5vstems
Polystick MTS or MTS PLUS followed by Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Tile Pro, MU-% or Polyflex
SAP is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with
the top -layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired.
Polystick MTS or MTS PLUS followed by Polystick TU P, TU Plus, TU Max, Tile Pro or Polyflex SAP is allowable for use
under foam -on tile systems. Limits of use are those associated with the top -layer material. This is not a requirement,
but is allowable if a 2-ply underlavment system is desired.
6.5.1 Elastoflex G TU, Elastoflex S6G or Elastoflex S6 G FIR shall be installed -in compliance with current Polyglass published
installation requirements. For use in tile applications:
✓ Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single
Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or -the Hot Asphalt
applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04.12) beneath mechanically fastened or
adhered the roof systems.
✓ Elastoflex S6 G is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply
System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened file roof systems or the Hot Asphalt
applied "Cap Sheet" in the "Two Ply System" from FRSA%TRI April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S6 G Fit is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single
Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened file roof systems or the Hot Asphalt
applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile
roof systems.
6.5.2 For hot -asphalt -applications, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FIR shall be fully asphalt -applied to the
substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, off -set
minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt
with asphalt extending approximately 3/8-inch beyond the lap edge.
Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements.
For use in tile applications:
✓ Polyflex G is for use as an alternate to the Heat Applied `Cap Sheet" in the "Two Ply System" from FRSA/TRI April
2012 (04-12) beneath mechanically fastened or adhered tile roof systems (Base Sheet Limited per 5.6.3).
✓ Polyflex 6 FIR is for use as an alternate to the Heat Applied "Cap Sheet° in the "Two Ply System" from FRSA/TRI
April 2012 (04.12) beneath mechanically fastened the roof systems (Base Sheet Limited per 5.6.3). .
NEMO ETC, UC. Evaluation Report P12060.02.09-R24
Cert(core o(Avrhonrotion C32455 6"'EOITION 12017) FSC NON'HVH2 EVALUATION FL5259-R28
Polyglass Roof Umlerlayments; (954) 233.1230 Revision 24: 01/24/20' 8
Page 13 of 14
ONEMOjeft.
6.6.2 Poiyflex G or PoWex G FR shall be fully torch -applied to the substrates noted in Section 5.6. Side laps shall be
minimum 3-inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course. Side and end
laps shall be fully heat -welded and inspected to ensure minimum 3/8-Inch flow of modified compound beyond the lap
edge.
6_7 Tile Staging:
6.7.1 Tile shall be loaded .and.staged.In a manner that prevents the slippage and/or damage to the. underlayment. Refer to
Table 2 herein, and Polyglass published requirements for tile staging.
6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI April 2012 (04-12)'must be used
on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or nail -
boards, to prevent tile sliding and/or damage to the underlayment during the loading process.
6.7.3 Pdlyglass specifies the minimum cure time after installation of self -adhering membranes and before loading of
roofing tiles is forty-eight (48) hours.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
S. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. 61G20-3 CIA requirements. The following
plants have qualified products under their respective physical properties specifications.
Ferule , NV, Hazleton, PA & Winter Haven FL
ASTM D1970
Pol lok MU•X
Hatleton, PA
M-D 13-0004
Elastollex G TU
I Hazleton, PA & Winter Haven, FL
ASTM D1970
Pohatick IR-Xe
ASTM D1970 & FRSA/TRI April 2012
Polystick TU Plus
ASTM D1970 & FRSA/TRI April 2012
Polystick TU Max
Tuscaloosa, AL
ASTM D4601, Type It
Pol glass G2 Base -
Winter Haven, FL-.--
1
ASTM D226 (physicals)
Elastobase, ElaAabase P
ASTM D6509
Polyglass APP Base
FRSA/TRI April 2012
Pol stick MTS, Pol stick MTS PLUS
FRSAJTRI April 2012
Pol stick TU P
FRSA/TRI April 2012
Poi ex SAP, Poi ex SA P FR
ASTM D1970
Polystick Dual Pro
ASTM D1970 & FRSA/TRI April 2012
PoNstick Tile Pro
ASTM D6164
Elastoflex $6, ElastoRex $6 G FR
ASTM D6222
PolVflex G, Po ex G FR
9. QUALITY ASSURANCE ENTITY:
UL, LLC— QUA9625; (314) 578-3406; k.chanceilor@us.ul.com
END OF EVALUATION REPORT -
NEMO ETC. I.I.C. Evaluation Report P12060.02.09-R24
CalifirateoJAPlbo'llo6a103243S e"EDITION J20171 FBC NON•HVHI EVALUATION Ft5259-R25
Palyglass Roof Undedaymertts; (954) 233-IM Revision 24: 01/24i2018
Page 14 of 14