Loading...
HomeMy WebLinkAboutEVALUATION REPORTRECEIVED FEB 44 2019 ST, Lucie County, Permitting Neflllt.2 j farce Cartificoca afAutnorlmtion 032e55 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY _ EVALUATION REPORT Polyglass USA, Inc. T}l Evaluation Report P12060.02.09-R24 Deerfield West Newport Center Drive SCANNED FLS2S9-R28 Dfield Reach, FL 33442 BY Date of Issuance: 02/24/2009 (954)233-1230 St. Lucie County Revision 24:01/24/2018 SCOPE: This Evaluation Report is issued Linder Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6"i Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Polyglass Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the produrt(s), the Quality Assurance or the production facility location(s). NEMOIetc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety, INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. '1 his Evaluation Report consists of pages 1 through 14. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The;acsinlile seal appearing was auth,rized by Robert NCrnmP.n, P.E. on 01/24/2018. This does notserve as an electroniciliv signed document. CERTIFICATION OF INOEPENOENCE: 1. NEMoletc. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NF.M01 etc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robot Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMOIetc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.5 FlIIGwable Roof Covers_ ONEM0 j etc, Underlayment ; Asphalt Shingles Na)l.on Tllc ( Foam -On TileMetal Wood Shakes _ ^�_.,. ''• _ `Yts & Shing165 1 Slote , Elastobase yeS Yes Yes w _�— (945a Shaek In 2-ply ifiWm) (Base Shefi;nTPIY SVEfna Yes _.i VAS. F.astonas^ P Yes Yes Yes l— �. _. __.-_ __... __ Po!Y&! SG26aSe NO o sn et n2" tysWrem; Yes i fusn_�S-hea:_ )-pl. mi vet Yes Yes Y1.4 - -.. (8asssnee±m 2-6YsY3tam) NO No �> do.yglass APP base No '---_..—._-.. ._.._•.--,.,-` Yes (Fate shf5tin l•p:(synemi Yes (Bata Shfat in Upq oy5kam) _"'�- No _— NO .. ------y Nu I POlys[!ck M i 5 pt MTS PLUS Yes Yes -+�- Yes __ NO Yes _yes —^- Yes--+ __. .. .._ - _.___—.�._. - Ptllysh[k TU P NO ___ No -'-^---. N o -- 40 — —_-(...__._--_--1 Yes ! Yes_ ._-_..__ .�, Polystick TU Plus yes YES yes (See 5.5.11 _ No _�T. NU i .... Nu _.. i ._..,..__�_._....�_._._ ratysh[k N N.ex i No. Yet — Yes (See 5.51)! Yes - Yes —yes--- - Y-.--. _ _ pnl stick BuaS Prtl � Yes .`._...- Yes (See 5.5.1) _--- I Yes No Ycs PGWsnck T3ie Prp Yes NO Y_._.._..__y No ! Yes Yes Y'Es Pu1Ysn_tk MU-X ! Yes Yes _ No Yes Yes (See 5.5.1) No "'— Yes Yes ------- _Yes Yet_ Yes -- _ Yes .__._._.__ Eiasrofiex S6G _ — Yes �— Elastoflex 56 GfN '-- -- •,.._ Yes Yes i _ E)asto0er. G TU — I yet _-..)..__..__. Yes No Yes (See 5.5.1) - No No No Yes_ yes _.... y V - —'� yes VpiyflEk G FR _ Vey Yes --_ Yes (See S.5.1) -- Yes _ ,( yes I Yes _ Polyflex SAP n; .SAP FR----Yes -�— Yes Yes —"` No _No NO ..� —_Yes ._._ _ ' `�_y .,_ t s_ —(------- Mule-Hite>A-MP CaP Sheet � ___ —_ Yes (SeC 5S.1) No Yes Ypeg or SA AP.. Cap Shcet (Fle Yes Yes ! Yes (See 5.5.1) No Yes yes ' .5.5.1 "Foam -On Tile" is limited to use of the following Approved the adhesives / underlavment combinations !i�lOk}PA'81;6i{JL =.ZhTIYF%f!lrt�}"�*,!t,8}N/A_u _ I AdhesiveTApproval DAP Foam Toach'n Sea) Stormiloi da Pro7duLlo__f_� Underlayments i Tile. Adhesive L14506 I Polystick TU Plus, Polystick TU Max Onw7ilek3a,d_L22525_ - Po!ystick TU P, Polystick TU Plus, POlYflex SAP or Tile Pro —� iCP Adhesives PalyseYy AH.160 --------.�_ FL6332 _� Polystick TU P, Polystick TU Plus, RelyTU Max, Polyst)ck Tile Pro, Elastoflex G TU, Elastoflex S6 G, PolyfleX G, Polyflex SAP, P0lYfi" SA Cap FR, Mule -Hid SA-APP Cap Sfieet or Mule•Hide 5A•APP Cap Sheet (FRi ICP Adhesives Polysetr' RTA-1 ----------__. — FL6276 �_ Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro, : Elastoflex G TU, Elastoflex SG G, PGlyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cat) Sheet fr-Rl Refer to Tile Morsufocturer's oe Adhesive Manufacturer's Florida Product Approval for Overturning MomentResisiance Performance. ;. V MO ETC. ,.r. czm;rcolr uj nurhaerPLcap32aS5 Evaluation Report A720b0.01A9-R24 G'" EOmON (2017) W NON-HVH2 EVALUATION >L5259-e19 Polyg)as5 Roof Underlayments; (954) 233.1230 Roveolon 24; 01124/20/8 Page 5 of 14 5.6 5.6. i 5.6.2 5.6.3 Ail wab . Subsira—ss: L iMtct-Bondto Deck: poly -stick (all variations), Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP r (FR) self -adhered to; ap Sireet r New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing plywood; New or ex(sting,_unprimed-OS8;-ASTM-D41- primed -O$8; $outtiern-Yellow Pine; ASTM 041 primed Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "TIP System' Panels (designed and installed to meet wind loads for project). Note. Pplyglass does nOt require priming of new or existing plywood or 0S8 sheathing. New or existing plywood or OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes. EI astofiex G TU, Elastoflex 56 G or Elastoflex 56 G FR in hot asphalt to: ASTM D41 primed structural concrete. Polyflex G or Polyflex G FR torch -applied to: ASTM D41 primed structural concrete. Bond -to -Insulation: Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FRI self -adhered to: 11 AS'I`M C1289, Type 11, Class 1 polyisocyanurata or Type V polyisocyanurate-composite insulation; Dens Deck DuraGuard; Dens Deck Prime; or SECUROCK Gypsum -Fiber Roof Board. Elastoflex G TU, Elastoflex 56 G or Elastoflex S6 G FR in hot asphalt to: Dens Deck Prime pr SECUROCK Gypsum -Fiber Roof Board. Polyflex G or Polyflex G FR torch -applied to: r ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK G psum-Fibe Rf B y .r 00 card. fOr installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on the systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of the Insulation/underiaymentsystem in accordance with FBCSection 1504.3.1. Bon i�Mp�t�p;cglly Attaches—.�.: Polystick (all variations), POlyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Duai Pro ul Tile Pro self -adhered to: r ASTM D226, Type I Or-11 felt; Elastobase; Elastobase P or Mule -Hide Nail Base. Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ASTM D226, Type I or 11 felt; Elastobase; Elastobase P, Mule -Hide Nail Base or Polyglass G2 Base. Polyflex G or Polyflex G FR torch -applied to: r- Elastobas% Elastobase P, Mule-1 fide Nail Base, Polyglass G2 Base or Polyglass APR Rase For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Sectidn 5.6.4 herein, or as tested in accordance with FBC Section 1504.3.1. .aErtO FYr. uc. �:e WJi:ctror Au:nonwticn R3]455 e'601VON 17,D17) FaC NON-HVHZ EVALUATION evaluation Report 1`1206O0269-1124 Pulyglas Roof Undenayments; (954) 233.1230 ` 124, L-.8 Revision 24: 0.)24;:Ci& Papa 11 of =» EML? � P.T.C. 5.6.4 Wind Resistance for Underlavmant Systems in Foam-Qn Tile Applications: FRSA/TRI April 2012 (04.12) does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that arc not addressed in FRSA/TRI April 2012 (04.12) and are used In foam -on the applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already applied): Refer to FRSA/TRI April ZU1L iU4- 12). Appendix A, Table 1A or FBC 1609 for determination of design wind loads. ll1 Maximum P Design ressure = -g0gsf: Dark: Min.1S/32-InCh plywood to meet project requirements to satisfaction of Authority Having Jurisdiction Primer: None Base Ply: (OPtinnal) Polystick MIS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick' U P, Polystick TU Plus, Polystick TO Max, Polyflax SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FRI, self -adhered. #2 Maximum Design Prgssure =-97 S psf Deck; Min, 15/32-inch plywood to meet project requirements to satisfaction of Authority Hawng.lurisdieticn. Pnmer. PG100 or ASTM D41 Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -Adhered, Underlayment: Polystick TV P, Polystick TO Plus, Polystick TV Max, Polyflex SAP, Polyflex SAP Fit, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self-auhered and back -nailed within the selvedge -edge side laps using J2 ga x 1 :" ring shank nails through 32 ga., 1.5/8" diameter tin caps spaced 12•inch o.c. #3 Maximurn DeIign Pressure =-10>�sf: Deck: Min, 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: wa-3000 Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TO P, Polystick TO Plus, Polystick TO Max, Polyflex SAP, PolyflexSAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -mailed within the selvedge -edge side laps using i2 ga. s 1%•(n "ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12ch o.c. it4 Maximum D�slgn pre�sure^;�•135 nst: Deck: Min. 15/32-inch Plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) PG100 or ASTM D41 Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, seff-adhered: Joints; Min. 4-inch wide strips of Elastoflex SA•V over all plywood joints. Underlayment: Polystick TO P, Polystick TO Plus, Polystick TO Max, Polyflex SAP, Polyflex SAP FR, Mule -Bide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. 45 MaximumDesigns w- �- 15 s: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: P6100 or ASTM D41 Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment Polystick TO P. Polystick TO Plus, Polystick TO Max, Tile Pro, Polyflex SAP, Pulyffex SAP FR, Mule-flide SA-APP Cap Sheet and Mule -Hide SA-APP Cop Sheet (FR), self -adhered. 46 Maximum Design Pressure =-U2 5 psf; Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer PG1.00 or ASTM 041 Underlayment: Elastoflex G TO or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. 417 Maximum Pressure = -40 0 psf't: Deck: Min. IS/32-Inch OSB to meet Project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25-inch longx 1-Inch head diameter round metal cap mails Spacing: 6-inch O.C. at the 3-Inch wide side laps and 6-inch o.c. attwo (2) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Undcdayment: Polystick TO P, Polystick TO Plus, Polystick TO Max, Poiyflex SAP, Polyflex SAP FR, Mule -Hide SA•APP Cap Sheec and Mule -Bide SA•APP Cap Sheet (FR), self -adhered. Nf a^O ETC, W' I rgi/uatr afAataurzaPor. a;2435 6"EDITION 20a7 FBC NON• Evaluenon RePOR P110600209-6::: 1 I HPH2 4)233- 230 FL92n9-R2 i PefyglAi9 ROpr Untledayments; (9a4) ),33.1230 Revision 24: W,42013 sago 7 Of it. "NEPAc � e)re. #23 Maximum Oesien Pressur_ e � .g0, Bsf; Deck: Min.15/32-inch Plywood plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied undednyment) Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with CMG 3" Gatvalume Steel Plates, OMG Roofgrip #14 with OMG Flat Bottom Plates (AccuTrac), TrUfaSt HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 9-inch o.cat the 4-inch wide slde.laps and 9-inch ox atfour (4) equally spaced staggered center rows. Underlaynen6 Flastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch applied, 424 Maximum Design Pressure =-9750sf; Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch ox. at the 4-inch wide side laps and 4-inch o.c. at four (4) equally spaced staggered center rows. base Ply: (Optional) Polystick MIS or Polystick MIS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Puiyflex SAP Fit, Mule -Hide SA-APP Cap 5heet and Mule -Hide SA-APP Cap Sheet (Fit), self -adhered. #25 Maximum Design Pr ssure =-105 nsf: Deck: Min.15/32-inch Plywood to meet projeetrequirementsto satisfaction of Authority Having Jurisdiction Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch-appl)ed cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c. at the 2-Inch wide side laps and 6-Inch ox, at three (3) equally spaced staggered center rows. Underlayment: Elastoflox G "rU or Elastoflex SG G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #26 Maximum DgLgn - ressu• gy .;!, tJsf; Deck: Min. 19/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga, x 1.25-inch x 3/8-inch head diameter annular ringshank roofing nails at i-5/8-inch diameter tin naps Spacing: 6-inch o.r. at the 4-inch wide side laps and fi inch o.c, at four (4) equally spaced staggered center row$. Primer: PG100 or ASTM D41 primer at all tin -caps Base Ply: Polystick MIS or Polystick MIS PLUS, self -adhered Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP Fit, Mule -Hide SA APP Clio Sheet and Mule -Hide SA-APP Cap Sheet (FR), self-adhel'ed. 427 Maximum Desten presgure = -120 nsf: Deck: Min. 15/32-inch plywood Yo meet project requirements to satisfaction of Authority Having Jurisdiction tase Sheet: Elastabase (sanded toQ surface for hot- asphalt or torch -applied cap or poly -film surface for torch -applied cap) 'astenets: CMG #12 Standard Roofgrip or CMG #14 Plates Heavy Duty with OMG 3" Round Metal Plates or CMG Fiat Bottom fdetal Spacing! 6-inch o.c. at the 4-mch wide side laps and 6-mch ox. at five (5) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex 56 6, applied in full mopping of hot asphalt or Polyflex G, torch -applied. 428 Maximum Desien Pressure = 120 osf: Deck: Min. IS/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface) rasteners: Trufast 1112 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates Spacing; 6-inch o.c, at the 4-Inch wide side laps and &inch o.c. atfive (5) equally spaced staggered renter rows. Underlayment: Elastoflex G TU or Elasto#ex S6 6, applied in full mopping of hot asphalt. 5.6.4.1 All other direct•deck, adhered Polyglass underli yment systems beneath foam -on tile systems carry a Maximum Design Pressure of -45 psf. ioa.Jrnle Fn;hn;ropn. +,55 L'va)uati0n Report Pl'10u0 924 6"' EDITION (20171 FBC NON-HVHZ EVALUATION rt52ic.aeH P01yglau Roof Underiayments; (954) 233.1230 Rawson P4: 01 yi4i<'a18 Pagc 10 0I 1.1 OErVID etc, 5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet orr xeed that required under PRSA/TRI April 2012 (04,12), Appendix A, Table IA. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design Pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDI, FM Loss Prevention Data Sheet 1-29 and Roofing -Application -Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 129 (January 2016) for Zone 2/3 enhancements. S.7 Exposure Limitations' Etastobase, Elestobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 3o-ciays after installation, Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than go -days after installation. Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Dual Pro, Tile Pro or Elastoflex G TU shall not be left exposed for longer than Igo -days after installation. Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP cap Sheet (FR) does not have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 3U days. Flastoflex S6 G or Elastoflex S6 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the prepared roof covering is to be adheslve-set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum exposure is 180 days. 5.8 Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226 roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as set forth in Section 4.3, Note I of ASTM D1970-15, should be established as to slip resistance. 5.9 Tile 5IRRage f tmitatio�„ n�/TRI Ann[ 20, 12 (0_4 1211 When loading roof tiles on the underlayment in tiirect-deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles, (T1LE•SLi7P'GEi.VjiTfhl'i$'t'S>:�OIRQEsK;T3LE (N ALLITfQf7 . :..Underlayment TIIeProfiie Staging Method M3XIIrUM 4Rfope Elastoflex G TU Flat ! 10-tile stack Elastoflex Sfi G or 56 G FR '- Lugged ----- ' 8-tile stack (6 over 2) ~-6:12------- _-,--_" Flat or Lugged 6•ttfe stack (M1 over 2) -"--I --}-- _4:12 Polystick MTS or MTS PLUS :.._.— Flat 6-tilestack (4 over 2) _ _ _ Lugged 5;12 ` 6-tile stack (4 over 2)---'"--"`'--� Polystick Tile Pro _t 4:12 Flat d or Lugged I--^ —"` ..____._... -- .`.� 6-tile stack (4 over 2)� 7:12 -- '__ Flat 6-Ule slack (4 over 2) or StLtile stack _7;12 Polysnck'fU Max Lugged ---� f--------..--,a� 6-tile stack (4 over 2) �7:12^ 10-tile stack6:12 V f ' Polystick 7U P ;_--� Flat ,_" T 6-tile stack (4 over 2) 6;12--_- `I Lugged _ 6-tile stack(4 over 2) Polystfck TV Plus Flat or Lugged ___ 4:12�-_ 6-tile stark (4 over 2) __-___ ? .12 '-- _ Flat or L�—ugged 1 10-tile stack -'— ! Polyflex G or G FR — ---- 6:12 -� 1.....__�._ Flat ar Lvgged '_i.__`._—.. .—.-.-.r_.— 6-tile stack (4 over 2 1 Polyflex SA N ar 5A P FR -- ) 4:12 i -- Flat or Lugged 6-tile stack (4 over Z) I —' „�--"—"-- i Nrrno t rr., to "•'r.;,•ure <yAu: natlr;,a(iv'3Z45g 6"EOITION 2017FBCNON- GYalealiaa kaPorl P32a66.ti1 iri-R2A Polyglass Ract Underlayment; (954) 233 12130N i't5S55 :: �a Remsten 24; ai/24(2635 Page -1 of 14 UNNwoletc. G. INSTALLATION: 6.1 Potyglass Roof Underlayments shall be installed in accordance with Potyglass published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove �'"' any dust and debris prior to application, and prime the substrate (if applicable). I "6:3" slmthw.ac Ri&er% 6.3.1 Nan -Tile Applications _ -- -- � - .Shall be installed in compliance with the codified requirements for ASTM D226, Type If underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, POlyflex SAP, Poiyflex SA P FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G or PolyHex G FR, torch applied. Roof cover limitations are those are those associated with the tOP-layer underlayment, as set forth in Table 1. 6.3-2 lifeAOnllcations: - Elastobase, Elastobase P or Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the "Two Ply System' from FRSA/TRI April 2012 (04-12). Reference Is made to Table 1 and Section 5.6.4 herein, coupled with FRSA/TRI April 2012 (04-12) Installation Manual. 64:.- PoSystt4kMlS7f,Ti$QYIrS`!ft X2 aTU p i!'UPPI "� E,f7�FrorTrretPrb of RtTi'f X,pUP�yf%ikS%tP,,Rotyf(exSAP:F.ily Mule t�iie S dfRP CsepS,h�e�nmRRfrCe Ftt(fa �A�y1P�-L�)r�h�e�(R(Z)t ` ,< , � J r 6 4 t Shntl ha Installed In compliance with the codified requirements for ASIPA U1970 (except Polystic derlaymerit in FBC Table 11;07-1 1 f.,e ekn _r -------- 6.4.2 - ,.-- r .... �w wxc 6 to uu inxialieo. Direct -to -Deck with Mechanically Fastened Roof Covers All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP Cap Sheet or SA.APP Cap Sheet (FR) should be back -nailed in selvage edge seam in accordance with Potyglass / Mule - Hide back nailing guidelines. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum larch diameter metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back - nailed using the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face 01 membrane. The head lap membrane is to cover the area being back -nailed. A!! seal -lap seams (seivagc laps) must be firmly rolled with a minimum 28 lb. hand roller to ensure full contact and adhesion. For Dual Pro and Tile Pro, align the edge of the top sheet to the end of the glue pattern (tire sheet will overlap the fabric). All over -fabric and over -granule end4aps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified Wet/Dry Cement or Potyglass PGSO0 Modified Cement applied. in between the application of the lap. Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details NefmO ETC, u-c. Lengnate aJAumo••iobo" d324.55 EVoipatlOP Re Port P1206V.W.fA-1Q4 Frialoot 1201-1) FEIC NON-14111-12 EVALUATION Pi 9259•R2s Polyglass Roof Underlayments; ta54) 233-1230 Revision 24: e1R411201+i Pape 12 nr to I Repair of Polystick membranes is to be accomplished by applying Polyplus 5o Premium Modified Wet Dry CLIMO t or Polyglass PGS00 Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of the Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be installed in a water shedding manner. All Polystick membranes shall be. installed to ensure full contact with approved substrates. Polyglass requires a +ninimum of 40-lb weighted roller or, on steep Slopes, use of astiff -broom with approximately 40-lbs of load applied for the field membrane.— Hand rollers are acceptable for rolling of patches, laps (min, 28 lb roller) or small areas of the roof that are not accessible to a large roller or broom. 6.4.3 TillAAnpli ations not aflou ed jor Pillustk Val Pro I&& or Polystick MU X): Reference is made to'FRSA/TRY April 2012 (04.12) installation Manual and Table 1 herein, using the instructions noted above as a guideline. For mechanicaflyfastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Rase Sheet fastening shall be not less than FRSA/TRI April 2012 (04.121, Table 1. For adhesive -set tile applications, referto Section 5.6.4 herein. 6.4.4 Two (2) Ply Underlavme_ nt S ._._- Polystick MTS or MTS PLUS followed by Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Tile Pro, MU-X or Polyflex SAP is allowable for use under mechanically attach prepared roof systems. Limits of use are those associated with the top -layer material- This is not a requirement, but is allowable if a 2-ply underlayment system is desired. Polystick MTS or MTS PLUS followed by Polystick TU P, TU Pius, TU Max, Tile Pro or Polyflex SAP is allowable for use. under foam -on the systems. Limits of use are those associated with the top -layer material. This is not a requirement, _ but is allowable if a 2-ply underlayment system is desired. 77 6.5.1 Elastoflex G TU, Elastofex S6 60 or£Iastofiex S6 G FRshall be installed in compliance with current Polyglass published installation requirements. For use m the applications: ✓ Elastoflex G TV {s far use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380r Class M) in the ".S(ng(e Ply System" from FRSA(TRI April 20i2 (iNz beneath mechanically fastened ule roof systems or the Hot Asphalt applied "Cap Sheet" in the "T'wo Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered the roof systems. ✓ Elastoflex S6 G is for use as an alternate to "Mineral Surface Roil Roofing" (ASTM D6380, Gass M) in the "Single Ply System" from FRSA/TRI April 2012 (04.12) beneath mechanically fastened tile roof systems or the licit Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Elastoflex S6 G FR is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04.12) beneath mechanically fastened the roof systems or the Hot Asphalt applied "Cap Sheet" in the "rwo Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. 6.5.2 For hot -asphalt -applications, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR shall be fully asphalt -applied to the substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end -laps minimum 6-Inch wide, off -set minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt With asphalt extending approximately 3/8-inch beyond the lap edge. 6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications: ✓ Polyflex G is for use a$ an alternate to the Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRl April 2012 (04.12) beneath mechanically fastened or adhered the roof systems (Base Sheet Limited per S.6.3). ✓ Polyflex G FR is for use as an alternate to the Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems (Base Sheet Limited per 5.6.3). rc.hmo ETC, tu. eariJenr" ¢i aua+enm++"n r+d745.5 Cw1vation Itoport P71ULV U2.u'e-a2A 6'" EDITION 12017) fah NON•liVI',Z EVALVATION PolYBlass Roof Underla l!"A;'N2a ymants; {aSGI 1a3-1130 ReV�non l.4• ot!:ai: a S PNge i3 of 1.4 6.6.2 Polyflex G or Polyflex G FR shall be fully torch•applied to the substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wid-set minimum 3 feet from course to course. Side ano end to e, off laps shall be fully heat -welded and inspected to ensure minimum 3/8--inch flow of modified compound beyond the lap edge. 6_7 TileStyginat 6.7.1 Tile shall be loaded -and staged in a -manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2 herein, and Polyglass published requirements for file staging. 6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRf April 2012 (04--12) Must be used on all roof Slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or naii- boards, to prevent tile sliding and/or damage to the underlayment during the loading process, 6.7.3 PofyglaSS specifies the minimum cure time after installation of self -adhering membranes and before loading of roofing tiles is forty-eight (48) hours. 7. BUILDING PERMIT REQUIREMENTS; As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product S. MANUFACTURING PLANTS; Contact the noted QA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements. The foliovwng plants have qualified products under their resoectivenhv<Iralnr.,nmm ;..«...._„--__,___ 2 UL, LLC — QUA9625; (314) 57a-3406; k.chancelior@us.ui.com - END OF EVALUATION REPORT hEbO ETC, L:C trrtd�m,e a,/nnf4oaorio�n32usi •* LvaNabon Report plleno 02.09-R24 6 EalassR ofUndul Nnants; f9 4j 233400N FWMI.e1R PalYalass-Roof Undarlaym¢nts; (9Sa) 233-123a Revli)ofl 24: 01/24/2018 page t4 pf 14 SCANNED NEMO I etc. BY CertiJ/cote ofAuthorizadon#32455 St. Lucie County 353 Christian Street, Unit #13 Oxford, CT 06478 (203)262-9245 - - ENGINEER - EVALUATE - - TEST - CONSULT .CERTIFY - - EVALUATION O. GAF Evaluation Report 01506.11.05-R22 1 Campus Drive FL5680-R22 Parsippany, NJ 07054 Date of Issuance:11/07/2005 (800) 766-3411 Revision 22: 10/17/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: GAF Modified Bitumen Roof Systems LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMOietc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOIetc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6, plus an 94-page Appendix. Prepared by: _ Robert J.M. Nieminen, P.E. :7.: ET1 a O'.i4a •�,�5,,.,.^ .o a_The facsimile seal appearing was authorized by Robert Florida Registration No. 59166, Florida DCA ANE1983 "swat 9:^• '' Nleminen,P.E.on 10/172018. This does not serve as an ;:t�,,,�e,,,,•:�. / electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither NEMO I etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ONEMOletc. ROOFING SYSTEMS EVALUATION: Product Category: Roofing Sub -Category: Modified Bitumen Roof Systems — -- -- --Compliance-Statement:—GAF-Modified-Bitumen-Roof-Systems,--as-produced-by-GAF,-have-demonstrated---- compliance with the following sections of the 6" Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Pro a Standard Year 1504.3.1 Wind FM 4474 2011 1515.1.1 Wind TAS 114 2011 1504.7 Impact FM 4470 2012 1507.11.2 Physicals ASTM D6162 2008 1507.11.2 Physicals ASTM D6163 2008 1507.11.2 Physicals ASTM D6164 2011 1507.11.2 Physicals ASTM D6222 2011 3. REFERENCES: gntitt Examination Reference Date Enti Examination Reference Date ACRC (TST4671) TAS 114 ACRC 06-041 11/10/2006 FM (TST1867) FM 4470/4474 797-05748-267 08/10/2010 ACRC (TST4671) TAS 114 ACRC 06-042 11/14/2006 FM (TST1867) FM 4470/4474 3040738 11/16/2010 ACRC (TST4671) TAS 114 ACRC 06-043 11/16/2006 FM (TST3867) FM 4470/4474 3036960 11/30/2010 ACRC(TST4671) TAS 114 ACRC 006-044 11/16/2006 FM (TST1867) FM 4470/4474 797-06129-267 01/13/2011 ACRC(TST4671) TAS 114 ACRC 06-048 12/21/2006 FM (TST1867) FM 4470/4474 797-06177-267 03/16/2011 ACRC (TST4571) TAS 114 ACRC 06-049 12/22/2006 FM (TST1867) FM 447OM74 797-06540-267 06/21/2011 ACRC (TST4671) TAS 114 ACRC 06-050 12/28/2006 FM (TST1867) FM 4470/4474 797-0680 267 09/29/2011 ACRC(TST4671) TA5114 ACRC07-006 01/17/2007 FM (TST1867) FM 4470/4474 797-07038-267 01/10/2012 ACRC(TST4671) TA5114 ACRC07-018 04/20/2007 FM (TST1867) FM 4470/4474 797-07073-267 01/19/2012 ACRC(TST4671) TAS 114 ACRC07-028 05/08/2007 FM (TST1867) FM 4470/4474 3038128 07/26/2010 ACRC (TST4671) TAS 114 ACRC 07-030 05/09/2007 FM (TST1867) FM 4470/4474 3040738 11/16/2010 ACRC(TST4571) TAS 114 ACRC07-032 05/10/2007 FM (TST1867) FM 4470/4474 3MIS35 06/09/2011 ACRC(TST4671) TAS 114 ACRC07-033 05/10/2007 FM (TST1867) FM 4470/4474 3G44688 03/01/2012 ACRC(TST4671) TAS 114 ACRC07-041 08/31/2007 FM(TST1867) FM 4470/4474 797-07198-267 03/01/2022 ACRC(TST4671) TAS114 ACRC07-044 09/05/2007 FM (TST1867) FM 4470/4474 3G44688(Re-Issue) 03/16/2012 ACRC(TST4671) TA5114 ACRC07-047 09/07/2007 FM(TST1867) FM 4470/4474 3044541 04/04/2012 ACRC (TST4671) TAS 114 ACRC 07-081 01/10/2008 FM (TST18671 FM 4470/4474 3044862 05/11/2012 ACRC (TST4671) TAS 114 ACRC 07-082 01/11/2008 FM (TST1867) FM 4470/4474 3043900 08/16/2012 ACRC (TST4671) TAS 114 ACRC 08-024 04/18/2008 FM (TST1867) FM 4470/4474 3046280 08/22/2012 ACRC (TST4671) TAS 114 ACRC 08-034 05/19/2008 FM (TST1867) FM 4470/4474 3046388 09/24/2012 ACRC (TST4671) TAS 114 ACRC OB-044 07/01/2008 FM DST3867) FM 4470/4474 3041769 09/27/2012 ACRC (TST4671) TAS 114 ACRC 11-G43 08/08/2011 FM DST3867) FM 4470/4474 3046403 09/28/2012 ACRC (TST4671) TA5114 ACRC 11-046 08/09/2011 FM D51­3867) FM 4470/4474 3046054 22/21/2012 ACRC(TST4671) TA5114 ACRC11-048 08/10/2011 FM (TST1867) FM 4470/4474 3MG081 02/13/2013 ACRC(TST4671) TAS 114 ACRCll-049 08/10/2011 FM D51­1867) FM 4470/4474 797-08216-267 04/11/2013 ACRC(TST4671) TAS 114 ACRC11-050 08/11/2011 FM (TST1867) FM 4470/4474 3048122 04/29/2013 ACRC(TST4671) TAS 114 ACRC11-051 08/11/2011 FM (TST1867) FM 4470/4474 3047104 OS/10/2013 ACRC(TST4671) TAS 114 ACRC 11-052 08/12/2011 FM(TST1867) FM 4470/4474 797-08263-267 05/23/2013 ACRC (TST4671) TAS 114 ACRC 11-053 08/17/2011 FM (TST1867) FM 4470/4474 797-08164-267 05/23/2013 ACRC(TST4671) TA5114 ACRC11-054 08/17/2011 FM(TST3867) FM 4470/4474 3047237 07/15/2013 ACRC (TST4671) TAS 114 ACRC 12-015 04/24/2012 FM (TST1867) FM 4470/4474 797-08670-267 09/16/2013 ACRC (TST4671) TA5114 ACRC 12-026 05/10/2012 FM (TST1867) FM 4470/4474 797-08873-267 11/26/2013 ACRC(TST4671) TAS 114 ACRC 12-034 08/10/2012 FM CW1867) FM 4470/4474 3048871 12/11/2013 ACRC(TST46711 TAS 114 ACRC 12-035 08/13/2012 FM (TST1867) FM 4470/4474 3048066 12/23/2013 ACRC(TST4671) TAS 114 ACRC 16-002 03/04/2016 FM OW1867) FM 4470/4474 797-09016-267 12/17/2013 ERD (TST6049) TA5114/FM4474 01880.09.03 09/10/2003 FM (TST1867) FM 4470/4474 3049496 22/19/2013 ERD(TSrGD49) TAS IWFM4474 01516.04.06 04/20/2006 FM DST1867) FM 4470/4474 3049601 01/29/2014 ERD (TST6049) TA5114/FM4474 4482.10.97-1 12/0Zf2006 FM (TST1867) FM 4470/4474 797-09984-267 20/28/2014 ERD (TSM049) TAS 114/FM4474 134280 V+B.10.06-R1 12/06/2007 FM (TST1867) FM 4470/4474 797-09987-267 10/28/2014 ERD CM6049) Physical Properties G6850.08.08 08/01/2008 FM DST3867) FM 4470/4474 797-10017-267 11/06/2014 'ERD (TST6049) Physical Properties G6850.08.084 08/29/2008 FM (TST1867) FM 4470/4474 RR205568 06/15/2016 ERD (TST6049) Physical Properties G6850.10.08 10/06/2008 FM (TST1867) FM 4470/4474 RR205474 08/31/2016 ERD (TST6049) Physical Properties G6850.11.08 11/05/2008 FM DST3867) FM 4470/4474 3059483 12/09/2016 NEMO ETC, LLC Evaluation Report 03506.11.04-R22 Certificate Of Authorization N32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION FL5680-R22 GAF Modified Bitumen Roof Systems Revision 22:10/17/2018 Page 2 of 6 21) gntitt Examination Reference Date Enti Examination ERD(TST6049) Physical Properties G12210.06.09 a8/03/2009 FM (TST1867) FM 4470/4474 ERD(TST6049) Physical Properties G12210.01.30 01/08/2010 FM (TST1867) FM 4470/4474 ERD(TST6M9) Physical Properties G31360.03.10 03/31/2010 FM(M1867) FM 4470/4474 ERD(TST6049) Physical Properties G33470.01.11 01/13/2011 FM (TST1867) FM 44701"74 ERD(TST6D49) TAS 114/FM4474 G36780.07.11-RS 07/18/2011 FM(TST1867) FM 4470/4474 ERD(TST6049) Physical Properties G40620.07.12-2 07/17/2012 FM OV1867) FM 4470/4474 ERD(TST6D49) Physical Properties G43190.11.13-1 11/15/2013' FM (TST1867)- FM 4470/4474 ERD(TST6049) Physical Properties G40630.01.14-1 01/06/2014 FM (TST1867) FM 4470/4474 ERD(TST6049) Physical Properties G40630.01.14-2A 01/07/2014 IRT(TST7408) TAS 114 ERD(TST6M9) Physical Properties G40630.01.14-2A-1 01/07/2014 IRT(TST7408) TAS 124 ERD(TST6049) Physical Properties G40630.01.14-2B 01/07/2014 IRT(TST7408) TAS 114 ERD(TST6049) Physical Properties G40630.01.14-2C 01/07/2014 IRT(TST7408) TAS 114 ERD ITST6049) Physical Properties G43180.01.14-1 01/10/2014 IRT(TST7408) TAS 114 ERD (TST6G49) TAS 114/FM4474 SC8580.11.15-3 11/09/2015 IRT(TST7408) TAS 114 ERD(TST6049) TAS 114/FM4474 SC8580.01.16-1 01/20/2016 IRTITST7408) TAS 114 ERD(TST6049) Physical Properties GAF-XI3285.02.17-2 02/08/2017 IRT(TST7408) TAS 114 ERD(TST6049) Physical Properties GAF-SC13285.03.17A 03/01/2017 ITS CMT1558) TAS 114 ERD(TST6049) Physical Properties GAF-SC13285.03.17A 03/08/2017 ITS(T5T1558) TAS 114 ERD (TST6049) Physical Properties GAF-SC13105.03.17-R1 04/04/2017 M-D (CER1592) TAS 124 ERD (TSTGD49) Physical Properties GAF-5C13285.03.17-5 05/23/2017 M-D (CER1592) TAS 114 ERD (TST6049) Physical Properties GAF-SC15710.12.17-2 12/31/2017 M-D (CER3592) TAS 114 ERD(TST6049) Physical Properties WF-SC16440.12.17 12/31/2017 MTI(TST2508) Physical Properties ERD (TST6049) TAS 114/FM4474 GAF-SC16825.12.17-1 12/31/2017 MTI (TST2508) Physical Properties F-TEC(TST7393) TAS 114 08-050187 04/28/2008 NEMO(T5T6049) ASTM D6163 F-TEC(TST7393) TAS 114 08-050188 04/28/2008 PRI (M5878) Physical Properties F-TEC(TST7393) TAS 114 08-070077 07/25/2008 PRI(TST5878) FM 4470/4474 F-TEC(TST7393) TAS 114 08-070094 07/25/2008 PRI(TST5878) FM 4470/4474 F-TEC(T5T7393) TAS 114 08-050181R 04/01/2009 PRI(TST5878) FM 4470/4474 F-TEC(TST7393) TAS 114 08-050186 10/14/2008 PRI(TST5878) FM 4470/4474 F-TEC(TST7393) TAS 114 08-070126 10/14/2008 PRI (TSr5878) FIA 4470/4474 F-TEC(TST7393) TAS 114 08-070122 30/14/2008 PRI (TST5878) FM 4470/4474 'F-TEC(TST7393) TAS 114 08-070127 10/14/2008 PRI(TST5878) FM 4470/4474 F-TEC(TST7393) TAS 114 08-080077 11/17/2008 PRI(TST5878) FM 4470/4474 FM (TST1867) FM 4470 IB9AB.AM 09/04/1997 PRI(TST5878) FM 4470/4474 FM (TST1867) FM 4470 3007500 06/15/2000 PRI(TSTS878) FM 4470/4474 FM (TST1867) FM 1470 3005640 11/09/2000 PRI(TST5878) FM 4470/4474 FM (TST1867) FM 4470 3008178 12/27/2000 PRI(TST5878) FM 4470/4474 FM(TSTI867) FM 4470 301021S 03/01/2001 PRI(TSTS878) FM 4470/4474 FM(TST1867) FM 4470 3009788 03/28/2001 PRI(TST5878) FM 4470/4474 FM (TST1867) FM 4470 3011140 08/14/2001 PRI M5878) FM 4470/4474 FM (TST1867) FM 4470 3013614 05/06/2002 PRI (TST5878) Criticality FM CW1867) FM 4470 3013798 01/10/2003 PRI(TST5878) FM 4470/4474 FM (TST1867) FM 4470 3014547 05/22/2003 PRI(TST5878) FM 4470/4474 FM (TST1867) FM 4470 3014692 08/05/2003 PRI M5878) FM 4470/4474 Fly(TST1867) FM 4470 3014960 03/05/2004 PRI(TSTS878) FM 4470/4474 FM(T5T1867) FM 4470/4474 3017250 04/05/2004 PRI(TST5878) FM 4470/4474 FM (TST1867) FM 4470/4474 3022139 05/26/2005 PRI(TST5878) FM 4470/4474 FM (TST1867) FM 4470/4474 3022508 07/20/2005 PRI M5878) FM U70/4474 FM (TST1867) FM 4470/4474 3025023 12/14/2005 PRI(TSr5878) FM 1470/4474 FM (TST1867) FM 4470/4474 797-02095-267 04/26/2006 PRI(TST5878) FM 4470/4474 FM (TST1867) FM 4470/4474 3023458 07/18/2006 PRI(TST5878) FM 4470/4474 FM (TST1867) FM 4470/4474 3028039 09/11/2006 PRI(TST5878) FM 4470/4474 FM (TST1867) FM 4470/4474 3024805 11/20/2006 PRI(TST5878) FM 4470/4474 Fly(TST1867) FM 1470/4474 3032388 10/30/2008 PRI(TST5878) FM 4470/4474 FM (TST1867) FM 4470/4474 3032695 10/30/2008 PRI(TSTS878) FM 4470/4474 FM(TST1867) FM 4470/4474 3032943 11/06/2008 PRI(TST5878) FM 4470/4474 FM (TST1867) FM 4470/4474 3032811 12/11/2008 PRI(TST5878) FM 4470/4474 -FM(TST1867) FM 4470/4474 3033719 01/16/2009 PRI(TST5878) FM 4470/4474 FM(TST1867) FM M70/4474 3035864 06/03/2009 PRI(TST5878) Criticality FM (TST1867) FM 4470/4474 3032172 06/12/2009 PRI(TST5878) Criticality FM (TST1867) FM U70/4474 3035140 08/10/2009 PRI(TST5878) FM 4470/4474 FM {TST1867) FM 4470/4474 3036225 08/10/2009 PRI (TST5878) FM 4470/4474 Fly(TST1867) FM 4470/4474 3034978 09/17/2009 PRI(TST5878) FM 4470/4474 FM (TST1867) FM 4470/4474 797-05447-267 04/13/2010 PRI(TST5878) FM 4470/4474 FM(TST1867) FM 4470/4474 797-OS487-267 05/12/2030 PRI(TST5878) FM 4470/4474 FM (TST1867) FM 4470/4474 797-05550-267 05/25/2010 PRI(TS175878) FM 4470/4474 FM(TST1867) FM 4470/4474 797-05538-267 05/25/2010 UL(QUA9625) QualityAssurance FM(TST1867) FM 4470/4474 797-05594-267 06/01/2010 UL(QUA9625) QualityAssurance FM (TST1867) FM 1470/41474 797-05695-267 07/15/2010 UL(QUA9625) QualityAssurance FM (TST1867) FM 4470/4474 797-05683-267 07/21/2010 UL(QUA9625) QualityAssurance FM (TST1867) FM 4470/4474 797-05687-267 07/21/2010 UL(QUA9625) Quality Assurance NEMO I etc. Reference Date RR208244 02/02/2017 RR208306 02/02/2017 RR208456 02/13/2017 3062588 (PLA) 08/01/2017 3055904 (letter) 20/03/2017 3055904 (data) 11/20/2017 Letter 02/13/2018 3061784 07/25/2018 00001 03/30/2000 00002 03/30/2000 01-039 01/24/2002 02-OD5 01/24/2002 02-014 03/26/2002 03-003 04/21/2003 03-004 D4/21/2003 04-008 01/26/2004 H9586.03-109-18 09/17/2018 H9586.04-109-18 09/17/2018 13-0617.20 09/05/2013 1}0307.02 09/26/2013 13-1007.09 01/30/2014 AX04C9A 06/05/2009 RX3009C 07/09/2009 4-GAF-18-001.07.18 07/31/2018 GAF-027-02-01 03/26/2002 GAF4M-02-01 09/16/2013 GAF434-02-03 09/16/2013 GAFA34-02-04 09/16/2013 GAF-436-02-02 03/06/2014 GAF436-02-03 03/06/2014 GAF436-02-04 03/06/2014 GAF436-02-05 03/06/2014 GAF-436-02-08 03/06/2014 GAF436-02-09 03/06/2014 GAF-549-02-01 08/08/2014 GAF-549-02-02 08/08/2014 GAF-559-02-01 10/16/2014 GAF-559-02-05 10/16/2014 GAF-559-02-06 10/16/2014 GAF-559-02-07 10/16/2014 GAF-559-02-08 10/16/2014 GAF-559-02-09 10/16/2014 GAF-559-02-11 10/16/2014 GAF-559-02-12 10/16/2014 GAF-559-02-13 10/16/2014 GAF-559-02-14 10/16/2014 GAF-559-02-15 10/16/2014 GAF-559-02-16 10/16/2014 GAF-559-02-17 10/16/2014 GAF559-02-18 10/16/2014 GAF-559-02-04-R1 03/04/2015 GAF-559-02-19 04/17/2015 GAF-746-02-05 12/15/2016 GAF-746-02-06 12/15/2016 GAF-755-02-01 02/02/2017 GAF-755-02-02 02/02/2017 GAF-755-02-03 02/02/2017 GAF-755-02-04 02/02/2017 GAF-743-02-01 09/14/2018 GAF-743-02-02 09/14/2018 GAF-743-02-03 09/21/2018 GAF-743-02-04 09/21/2018 GAF-743-02-05 09/21/2018 GAF-743-02-06 09/21/2018 GAF-743-02-08 09/21/2018 GAF-765-02-02 09/21/2018 Inspection (AL) 11/07/2017 Inspection (CAI) 11/05/2017 Inspection(CA2) 01/25/2018 Inspection (GA) 01/25/2018 Inspection (IN) 01/10/2018 NEMO ETC, LLC Evaluation Report 01506.11.04-R22 Certificate of Authorization#32455 6TH EDITION (2027)FBC NON-HVHZ EVALUATION FL5680-1122 GAF Modified Bitumen Roof Systems Revision 22: 10/17/2018 Page 3 of 6 This Evaluation Report covers GAF Modified Bitumen Roof Systems i installation instructions and the Limitations / Conditions of Use herein. ONEMOIetc. in accordance with GAF published — ----Type- - - TABLE 1: ROLL -GOODS FOR GAF MODIFIED BITUMEN - ------ Product ------- ROOF SYSTEMS -- --- _Specification_ Reference Type Grade GAFGLASs #75 Base Sheet ASTM D4601 II N/A Tri-Ply® #75 Base Sheet ASTM D4601 II N/A GAFGLAS® #80 Ultima" Base Sheet ASTM D4601 II N/A Base Sheet StormSafe"• Anchor Sheet Proprietary N/A N/A GAFGLASo Stratavent® Nailable Venting Base Sheet ASTM D4897 II N/A GAFGLASe Stratavent® Perforated Venting Base Sheet ASTM D4897 II N/A Liberty'" SBS Mechanically Attached Base Sheet Proprietary N/A N/A GAFGLAS® Ply 4 ASTM D2178 IV N/A Ply Sheet Tri-Ply® Ply 4 Ply Sheet ASTM D2178 IV N/A GAFGLAS® FlexPly— 6 ASTM D2178 VI N/A LiberWm SBS Self -Adhering Base/Ply Sheet ASTM D1970 ASTM D4601 N/A II N/A WeatherWatch® XT Mat Surfaced Leak Barrier ASTM D1970 N/A N/A Ruberoid® SA Universal Base Sheet ASTM D6163 I S Ruberoid® 20 Smooth ASTM D6163 1 S Smooth Surfaced Ruberoid® HW 25 Smooth ASTM D6163 I S Membranes: Ruberoid® HW Smooth ASTM D6164 I S Ruberoid® Mop Smooth ASTM D6164 I S Ruberoid® Mop Smooth 1.5 ASTM D6164 I 5 Ruberoid® Mop Plus Smooth ASTM D6164 II S Ruberoid®Torch Smooth ASTM D6222 I S Tri-Ply® APP Smooth Membrane ASTM D6222 I S Ruberoid®30 Granule ASTM D6163 I G RuberoW 30 Granule FR ASTM D6163 I G Ruberoid® Ener&Cap'" 30 Granule FR ASTM D6163 I G Uberty' SBS Self -Adhering Cap Sheet ASTM D6164 I G Ruberoids Mop Granule FR ASTM D6164 I G Ruberoid® Mop Granule ASTM D6164 I G Intec Flex PRF ASTM D6164 I G Tri-Ply® SBS Granule Cap Sheet ASTM D6164 I G Ruberoid® HW Granule ASTM D6164 I G Ruberoid® HW Granule FR ASTM D6164 I G Granule Surfaced Membranes: Ruberoid® Mop Plus Granule FR ASTM D6164 II G Ruberoid® Mop Plus Granule ASTM D6164 II G Ruberoid® EnergyCap'o Mop Plus Granule FR ASTM D6164 II G Ruberoid® HW Plus Granule ASTM D6164 II G Ruberoid® HW Plus Granule FR ASTM D6164 II G Ruberoid® EnergyCap'" HW Plus Granule FR ASTM D6164 II G Ruberoid°Torch Granule ASTM D6222 I G Tri-Ply® APP Granule Membrane ASTM D6222 I G Ruberoid® Torch Plus Granule FR ASTM D6222 II G Ruberoid® EnergyCap'" Torch Granule FR ASTM D6222 I G Ruberoid® EnergyCap- Torch Plus Granule FR ASTM D6222 II G NEMO ETC, LLC Ceniiicate o)Authori:ntion#32455 6- EDMON(2017) FBC NON-HVH2 EVAWAT1ON GAF Modified Bitumen Roof Systems Evaluation Report 01506.11.04-1122 F1.56800.1122 Revision 22:10/1712018 Page 4 of 6 ONEMOletc. 5.1 This is a building code evaluation. Neither NEMOI etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 _ This Evaluation Reportisnotforusein HVHZjurisdictions_ 5.3 Refer to a current UL Roofing Materials Directory for fire ratings of this product. 5.4 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. 5.5 The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.6 For recover installations, the existing roof shall be examined in accordance with FBC 1511. 5.7 For mechanically attached insulation or membrane or strip -bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordancewith FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a. qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD3, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.8 For assemblies with all components fully bonded in place, the maximum design pressure forthe selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 5.10 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or Roofing Application Standard RAS 111, except the basic wind speed shall be determined from FBC Figure 1609.3(1),1609.3(2) or 1609.3(3). 5.13 All products in the roof assembly shall have quality assurance in accordance with FAC Rule 61G20-3. NEMO ETC, LLC Evaluation Report 01506.11.04-R22 Certificate of Authorizodon#32a55 61H EDITION(20171 FBC NON-HVHZ EVALUATION FL56B0-R22 GAF Modified Bitumen Roof Systems Revision 22: 10/17/2018 Page 5 of 6 ONEMOletc. 6.1 GAF Modified Bitumen Roof Systems shall be installed in accordance with GAF published installation instructions, subject to the Limitations / Conditions of Use noted herein. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance_based_on allowable wind loads, and. reflects the ultimate_ passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 616204 QA requirements. UL, LLC—QUA9625; (847) 664-3281 -THE 94-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - NEMO ETC, LLC Evaluation Report 01506.31.04-R22 certificate of Authorization#32455 6-EDITION(2017)FBC NON-HVH2 EVALUATION FL5680-R22 GAF Modified Bitumen Roof Systems Revision 22:10/17/2018 Page 6 of 6