Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
REVISION - BUILDING PERMIT
OFFICE USE ONLY: DATE FILED: REVISION FEE: 25 PLANNING & DEVELOPM BUILDING & CODE REGULA 2300 VIRGINIA FORT PIERCE, FI (772) 462; APPLICATION FOR PROJECTIh LOCATION/SITE ADDRESS: 913 Jackson Way, Fort Pierce, FL 34949 PERMIT# 1902-0300 RECEIPT # '['30 DETAILED DESCRIPTION OF PROJECT SCANNED REVISIONS: BY St. Lucie County Penetration modification to roof type, attachments and design layout. CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CVC56965 BUSINESS NAME: Goldin solar, LLc QUALIFIERS NAME: oaren Goldin ADDRESS: 3447 Percival Avenue CITY: Miami S PHONE (DAYTIME): 772-284-3646 TATE: FL OWNER/BUILDER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME: STATE: ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME): ATE: ST. LUCIE CO CERT. #: CVC56965 FAX: FAX: FAX: ZIP: 33133 ZIP: ZIP: SLCCC 0' ., Revised 06130117 FIL COP e 'y lqcafD3Dv STRUCTURAL CALCULATIONS for Solar Photovoltaic System Project: Defabio Residence Address: 913 Jackson Way, Hutchinson Island, FL 34949-8518 GSN: 1901005 INDEX PAGE Scope and Data 1 ENV Data & Calculations 2 Module and Attachment Loads 3 Wind Details & Roof Zones Al Module Specification A2 Attachment Detail A3 REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC CE H00`%,,, STAT �7;-? 0 R 10 SS/ONAL��.� 'ffffflllllllllll\\\\ 1109 LIS-1, VERO BEACH, FL 32960 (772) 205-f �¢jmi In @ComY Note: The calculations are port of the construction Documents and shall match in specifications, codes and regulations. . Project: Defabio Residence No. 1901005 - GOL WKN60LAR Analyst: Amjad Mardi Revision Engineer: Holly Hoover, PE mil" Step 1: Scope and Data Purpose: Determine Wind Loads on MWFRS Solar Equipment Method: Directional Procedure for Appertenances Reference Standards: FBC 2017 (ASCE 7-10/7-16, Chap. 26-30), NEC 2015 (Art.690), IBC 2015, HUD hr T Risk Category II Table 1.5-1 he he Exposure Category C Sec. 26.7.3 j ! ELEVATION STRUCTURE DATA ABBR Bldg Type Enclosed Low -Rise <60 ft, hr < LHD Sec. 26.2 Roof Construction Gable Composite Shingle Field Survey (FS) Mean eave height he 8.0 ft FS/Eagleview 50 % eave height 4.0 ft Mean roof height hr 14.0 ft 40% mean roof height 5.6 ft Calculated Primary Roof Slope (0) 4:12 18 deg Eagleview Parapet height hpt N/A ft FS/Eagleview Mean canopy height h, N/A ft Building length WL 69.0 ft " 4% building length 2.8 ft " Building width Ws (B) 46.0 ft " 10% Least Horiz. Dim. LHD 4.6 ft Calculated Dead Load D 25 psf HUD Live Load L 20 psf 1. PV MODULE(M)DATA ABBR SOURCE Chord Length LP 5.56 ft Module Spec. (A2) Width w 3.28 ft Area A 18.25 ft2 (panel : panel gap > 0.25 in) " Thickness T 0.11 ft Weight W 41.45 lb Low Module Edge hl 0.5 ft See: Plan Sheet Sl, S2 High Module Edge h2 0.5 ft (10 in min.) 11 Angle to roof w 0 ' (tolerance of 2°) Calculated Distance to Roof Edge = 2h2 1.0 ft (min.) Test Pressure 113 psf Design Pressure 76 psf Test Pressure -84 psf Design Pressure -56 psf 1109 US-1, VERO BEACH, FL 32960 (772) 205-3244 permitting@goldinsolar.com Note. The Calculations are part of the Construction Documents and shall match in specifications, codes and regulations. 1 Project: Defabio Residence No. 1901005 EM ,= Analyst: Amjad Mardi Revision Go� otAR Engineer: Holly Hoover, PE ' Step 2-7: ENV Data & Calculations ENVIRONMENTAL DATA ABBR ASCE Source Basic Wind Speed V 160 mph ASCE 7 Hazard Tool Use per Bldg. Dept. V 170 mph Directional factor Kd 0.85 mph Table 26.6-1 Elevation factor Ke 1.0 < 1000 ft Table 26.9-1 Topographic factor K,f 1.0 Table 26.8-1 V pressure exposure K,_h 0.90 Table 26.10-1 Gust effect Factor Gf 0.85 Rigid Bldg N/A Mean elevation h 14.0 Velocity pressure = q,_h 57 psf = 0.00256 K, Krt Kd Vz a = 4.0 ft h/B = 0.3 Factors Range a 'f` -19` Equalization ya 0.40 (Figure29.4-8) 90i®,_0-9 Array Edge -YE 1.50 Exposed (-) Array Edge YE 1.00 All (+) Nonexposed ®;O; ®;OL Parapet yP - min (1.2, 0.9+hpt/h) Chord YC 3.94 max (0.6+0.06Lp, 0.8) Exposed Panel within 1.51-p 8.3 ft ®' ®7y® PLAN Edge Distance >2hz dl 1.0 ft (min) Gable roof Array Separation = dZ> 4.0 ft Roof Area: 2919 Total Modules: 27 Array Area: 493 Determine Wind Pressures P = gh(GCp)(YE)(Ya) on Array Cover: 17% Zone M(#) M(SF) GCp(+) GCp(-) Exposed % 1 21 347 0.3 -0.8 21 100% 2 13 146 0.5 -1.2 13 100% 3 GCp: External pressure coefficient; Table C30.3-3. Gable Roof, 7" < B <_200 (Figure 30.3-2B) Zone -YE (-) 7E (+) Ya % 1 1.50 1.00 0.40 62% 2 1.50 1.00 0.40 38% Wind Pressure (psf) P (+) P (-) Module Design 76 -56 Effective 9 -32 Margin 67 -24 OK 1109 US-1, VERO BEACH, FL 32960 (772) 205-3244 EMAIL: PERMITTING@GOLDINSOLAR.COM Note: The Calculations are part of the Construction Documents and shall match in specifications, codes and regulations. 2 Project: Defabio Residence No. Analyst: Amjad Mardi Revision GOEDIN60LAR Engineer: Holly Hoover, PE Step 2-7: ENV Data &Calculations SUPERIMPOSED LOAD CONNECTOR CAPACITY Roof Dead Load 25 psf Truss Member Type SYP Roof Live Load 20 psf Spacing 24 in o/c Total Load 45 psf Specific Gravity (G) 0.55 Section 2 x 4 in x in Module Weight 2.3 psf Source: NDS 2015 (TR12), FBC 2017 Safety Factor 2 Connector Type Lag Screw Diameter 5/16 in Module Deadload 4.5 psf Penetration 2.5 in (min) Roof Deadload 25 psf Number 2 Live Load 0 psf Total Load 30 psf 30 < 45 OK Withdrawal Capacity Lateral Resistance (Table 12J) W = 1800 G3/2D % 307 lb/in 1-3/4", Z 140 lb Short Duration Factor 1.6 Group Factor (Table 11.2.6A) 0.98 lb W * SDF = 1227 Ib / screw LR * GF * STF = 220 lb Total Capacity 2455 lb Lateral Pressure (max) 85 psf Uplift Pressure -32 psf Tributory Area 0.5 sf Tributary Area (TA) 12 sf Lateral Load on screws 42 lb/screw Uplift -388 lb Safety Factor 1.67 Assembly Weight/TA 31 lb Shear Force / screw 35 lb Net Tension / 2 screws 2098 lb 35 < 220 OK OK Set Chord Edge Distance (Table 12.5.1C) Set Connector Spacing (Table 12.5.11)) L/D = 8.0 psf L/D >_ 6.0; 5D = 1.6 in L/D z 6.0; 1.51) = 0.5 in Provide 2.5 in o/c Provide 0.75 in o/c 1109 US-1, VERO BEACH, FL 32960 (772) 205-3244 EMAIL: PERMITTING@GOLD]NSOLAR.COM Note: The Calculations are part of the Construction Documents and shall match in specifications, codes and regulations. 3 GO I-011W60LAR ,On I:ucle Wind Details and Roof Zones - ;� -N L.I-,. •• W -'. -f 2K P i Y J3clea WaY-O L-LVNtl 3peetl 160 Vmptl p lOyee�MW: IBlNmpll . 25Yeal MM 1"Vmpb SO"MNI 119 Vmp11. '00,na MM 131 Vmpb V W'e pro WeEI 3 -Cquat LIO peeUie133R ltpva9rOuM lot Fippsure CCafepory EueJ IN Mt � tM Uetweemm�b WiN polo peetla are bteryalelMln cwd w11114s]l SWb dar VME speMa. caiespenet ppieilmeieh' ]%prebeEilltY IeaceeEe _ In sa yeaa� ( �nuel eeda_Ma piotialtlOry OOOlC3;MN ]OOY aie): Sibla Ma Mnksnepene repbn ea deOneOb/S SG]]165ecllen 2&2 GIattO ppeNnpa aNY Ge Ratactatl aBaNst w4aFEOme lelab as ¢ped(IeO In SMIan 36121 R �aswn fSCF/SEI]t6 Fl¢26510 G ,Lam -N¢vga�\ 6. I rJfrls all _ :PopprvaA - )` _= aUnm c`A.` - -�1Yegp.VGeQupn Y Ft P.—Cut Fl9a. bbM . �Y �F PPb 161 r 4. u: 1109 US-1, VERO BEACH, FL 32960 (772)205-3244permitting@goldinsolar.com I Note. The Calculations are part of the Construction Documents and shall match in specifications, codes and regulations. Al GOL-DIN'SOLAR W-11/1' MODULE SPECIFICATION format IG85n. . 1000mmx32rm rne4d,'ng trace) Yre(iM 187Ig hoot Cater 72ram ll<rroDr ptrtrc<d nith Yack C¢rer Canpcite ran Frame 81xk a'mG?r_.f ahninun CeII ---- 6x ZO mavary-.talline 0ANlULl zelar half Nl: hac8m Rea 7a B5mm x5S70nenx lY2lnm Pntxiion ets:IPG7, nigh b/Fa=-dcde: � G6te-^-------/1rsn�ScLr eaNt (A 11001r_I, f-11700am Goaeetar M.W-C..ta_I, MCA. IPGS and IPGB dlMLelaI PEItFO WABCEAT SUMAIRD TEST PGt eralMPW stele drnoe• � f o;caa------ �ml�ra�u¢r j CCaeDtattBP `—__ �. Y01M¢e at MPP `. �r� �•]-tom=` 31s _ _ 320 - _ _ _- 325 2" 3W/-OW7 315 _ 320 325 330 i 10.00 1D.09 10.1A —~--- IOSO , 39.87 40_13 40.40 40.GG I 955 9.LD 9.LG 971 _ 329E _ 3332 33.G5 33.99 218.7 �19.0-i��193 239.L PaztPratlIDPa P. IW) 233A 2372 ! e Simi Imalt drtCOl' Open grfAltYOlraCe• V. M 3730 --7 .55- __ C9IeDtatNDP __ Im EA] 7_51 7.56 VDlneeae MPP — _—Va M t'IOW.ltoe.5�,a¢i9n AY 154 •Ymrcmoekraa[eaSTLs]Z:NCS ISZ •ROOM Y CII15 PEAi0114EAt/CE WAQQANTT, ASIa499S. ¢raJaln.V pnvdte8 ij l.� _°.,"",�wr irstynr. TeemF.aoa. QSCZ iBT� -�.�...� ... aa�]afa9aa pvprs.Nlaa 93.iZU s= n¢mTmpara ItPia l0I¢a'sN 1eS 'a=3 n 85Z01 DTnlml p¢nV Yp le 25ycr i� p - e Fe CIi�1C]I ^^^,rtcent eJrn2� Nc�1T.vDci In smNr<o WutS aralanY:av:N:MaC[LLSZL3 I � � ngmlauaa d you rc;c=va rmwy. Teaperamr-wefnCle-st Dl15 a IWK)' � TerC�en:DR [cefntl¢DtolPoai _ 240.9 —`21A.G ---- _- Bill 8.22 -� 3779 38.07 - --7.G0 3I70 Sill 1 ISS •gyGlnt�aa^JeNcf mll•alfa --- �_ 1 1 I 1 I i i i i 1 1 1 1 3 r Y -Y -•' - l C 1 1 1 1 1 s a 1 m mL]P4tetn am,p m to ecurgmaesysbactovaa'), xila tnsQtll•M b SIC cmmDrs(35Y. lflxNtm•1 I e0.at 7ertpefamreaetnde0e clYm -0?7 Romal 0peratio[ all Temwatcde NOCT�1'L)45_,. Mn1nDm lteRne drRDt It Oil 20 .FUe Rad:Z C I PaWPml IOaD 1Pe1 S40074OD3 Peraitte0 Mo0ole iempentsre �40'C cP ta.BS'C I I _(Ttlo-l0a0 b 1auGssttai� IE4G1215] 00 CmCo0faf DI YDCCmLy TC .ICCO715(CC2h ITLGI7]0(MILAPW�ant A T•.3ULi Stux1 mcpllcwll] DIN LY •^•g_ , OVE C Rani •••*1DJaa ln@u=cna mmtm mllTtC. am Na--amcn zCcp-a-e-axYar mut=twwC :m1¢n:Pa—tm C1L•erinmimSlal alYPYan I-btar n am c ¢t L1LFtoGu1 1109 US-1, VERO BEACH, FL 32960 (772) 205-3244 permitting@goldinsolar.com ►_IN Note: The Calculations are part of the Construction Documents and shall match in specifications, codes and regulations. GOL-DIN:SOLAR S-5-N Back 1.62n 1.69n 1.57in ATTACHMENT DETAIL Top 1.09in .591n- 7 M8-1.25 Threaded Hole Scale 1:1 Left Front GENERAL NOTFS: 1. S-5-NMINICLAMP 1•- 2. M8-1.25 SS HEX FLANGE BOLT (I 3MM SOCKET) 3. 3/8-24SS ROUND POINT SETSCREW (3/16 HEX DRIVq PV IdT 30 COMPONENTS 300 SERIES STAINLESS UMVERSALPV STUD K �t9T D } I-j f .49in Right .50iA59in 3/8-24 Threaded Hole MATERIAL: 6061 T6 At ESTASSEMBLY WEIGHT:0.268lbs SUPPLIED HARDWARE: Clamp: -x 16 nIDs) �3 Batt 31824x.S00(0.0345lbs) Setscrew(0.0170 lbs) � ImLtab Bimfanarvrt WWW.S5.COM MSHEXFLANGENUT ASSEMBLEDCOI 2R t 1 PV GRAB 30 u° um ii.'ss °m '� iim am EDGE 192N3391'A3113 7• S f 3 Sa IIS 1S [lC IEISl11lf.911i 1109 LIS-1, VERO BEACH, FL 32960 (772) 205-3244 permitting@goldinsolar.com Note: The Calculations arepart of the Construction Documents andshallmatch in speciJlcations, codes ondregulotions. A3 Defabio Residence - 8.5kW Solar Photovoltaic System 913 Jackson WaYA a St Lucie r� 3 '<s tiForP�jerce'., °i rk1 NavyUDT SEA _� t Inlet State` Pa11 t t -T 616 Fortie�rcze ' A� t Inlet State �' 0 Re ea . t creatronr � IAIA. x St LucleOld li ' " �' I !I �ii - • ^ Ft hlerQeiniet State;Pa'ik, ,cry s a+w Location Map l R-02-bwd SYSTEM SUMMARY 27 HANWHA Q.PEAK DUO-G5 320/325 MODULES 1 SOLAR EDGE 1000OH-US INVERTER ��cF S-5! SYSTEM - — - -- APB 9�91 ko 0i 8 SEIGc'`90P 1�I,Y SHEET INDEX SP SITE MAP AND PV PLAN 6 STRUCTURAL S1 MOUNTING & ATTACHMENT PLAN S2 ATTACHMENT DETAILS ELECTRICAL E1 ELECTRICAL RISER & SCHEDULES E2 DISCONNECT & WARNING LABELS CODE TABLE APPLICABLE CODES & CERTIFICATIONS: CODES STRUCTURAL: 2015 IBC/IEBC/IRC, FBC 2017 ELECTRICAL/FIRE SAFETY: 2017 IEC, 2014 NFPA 70 & 70A, FBC 2017 ENERGY: 2015 IECC, FBC 2017 MATERIALS CERTIFICATIONS OPTIMIZERS: UL1703SA REVIEWED FOR RA°KING:' UL2703 CODE COMPLIANCE RACJUNCTION BOX: NEMA4X WALK JUNCTION BOX: NEMA3R ST. LUCiIE COUNTY BOCC \\\\111111 CONTRACTOR "��CE H00/'°-'j' GOLDIN SOLAR, LLC E ''•. 1109 US HIGHWAY No.1 No. 6 ' VERO BEACH, FLORIDA 32960 CERTIFIED FLORIDA SOLAR CONTRACTOR G LAR = 7 CVC56965 STATE OF (772) 205-3244 :A <v Email: permitting@goldinsolar.com �',0^*-•FZ 0 R101l'.•' "� Web: www.GoldinSolar.com ����`,SS10NAL��G``�`` llllluunllt\lua\\ 913 3ackson Way, Fort Pierce, FL DISCLAIMER: PLAN SHEET FOR REFERENCE ONLY UNLESS SIGNED AND SEALED BY ENGINEER I GENERAL NOTES: 1. THE PROJECT IS DESIGNED IN GENERAL ACCORDANCE WITH THE FLORIDA BLDG CODE 2017 AND ADDITIONAL CODES AS ADDITIONALLY REFERENCED. 2. ABBREVIATIONS OTHER THAN AS PROVIDED IN TABLES/LEGENDS ARE INDUSTRY STANDARD. 3. CONDITION AND CONSTRUCTION OF ROOF FRAMING AND ROOF COVER LAYERS SHALL BE VERIFIED BY PHYSICAL INSPECTION AND ACCEPTED BY GOLDIN SOLAR AND ANY OTHER RESPECTIVE CONTRACTOR FOR WORK PRIOR TO PERMITTING ACTIVITIES. 4. ALL CONTRACTORS/SUB-CONTRACTORS SHALL BE LICENSED BY THE STATE OF FLORIDA AND AS REQUIRED BY PERMITTING AGENCY. - 5. NO UNLICENSED CONSTRUCTION WORKERS OR TRADE WORKERS SHALL BE ALLOWED ON JOBSITE. 6.ALL GENERAL CONTRACTORS AND SUB -CONTRACTORS SHALL INSPECT THE SITE AND ANY RESPECTIVE EXISTING BUILDING IMMEDIATLEY BEFORE PREPARING ANY BID AND BEFORE ORDERING ANY MATERIALS AND SHALL PROVIDE GOLDIN SOLAR WRITTEN NOTICE OF ANY DISCREPANCY BETWEEN FIELD CONDITIONS AND THE PLANS. AFTER VERIFYING THE WRITTEN NOTICE, GOLDIN SOLAR SHALL PREPARE ANY NECESSARY PLAN REVISION, GENERALLY WITHIN 72 HOURS OF SUCH NOTICE. 7. ANY PLAN DIMENSION NEEDED BUT NOT PROVIDED SHALL BE CONFIRMED WITH THE ENGINEER OF RECORD (EOR). 8. ALTERATION OF ANY UNPLANNED, STRUCTURAL ROOF OR WALL FRAMING SHALL BE APPROVED IN ADVANCE IN WRITING BY THE FOR AND OWNER AND PLANS SHALL BE SO REVISED. 9. FIRE PROTECTION PROCEDURES SHALL BE FOLLOWED IN ACCORDANCE WITH NEC 2014, Art. 690. SEE: SHEET E3 10. ALL WORK MUST BE INSPECTED BY FOR AND BUILDING INSPECTOR PRIOR TO COVER WHICH WOULD AFFECT EASE/DURATION OF INSPECTION. 11. BEST MANAGEMENT PRACTICES SHALL BE EXERCISED AT ALL TIMES TO MAINTAIN A SAFE AND CLEAN JOBSITE IN COORDINATION WITH THE PROPERTY OWNER; THIS APPLIES TO PARKING, TRASH REMOVAL, STORAGE, SOUND, UTILITIES AND TIMES OF WORK. 12. NO WORK SHALL BE PERFORMED IN RIGHT-OF-WAY WITHOUT WRITTEN PERMISSION FROM THE APPROPRIATE PERMITTING AGENCY. 13. ANY DAMAGE TO PROPERTY OR BUILDING NOT UNDER THE CONTROL OF GOLDIN SOLAR SHALL BE REMEDIED BY THE OWNER. 14. ALL NEW MATERIALS SHALL MATCH EXISTING MATERIALS WHERE VISIBLE AND SHALL BE APPROVED IN WRITING BY THE OWNER. 15. ALL MATERIALS NOT LISTED OR SPECIFIED HEREIN SHALL BE OBTAINED THROUGH CONTRACTOR -APPROVED VENDORS, GENERALLY NECESSARY TO COMPLETE TYPICAL SIMILAR CONSTRUCTION AND SHALL CONFORM TO CODE TABLE, INDUSTRY STANDARDS AND POLICIES OF THE PERMITTING AGENCY. 16. ALL DETAILS OR SPECIFICATION ARE CALLED OUT BY LOCATION OR AS APPLICABLE TO AN ARRAY. 17. IN THE EVENT OF WEATHER OR OTHER CIRCUMSTANCES THAT MATERIALLY AFFECT OR COULD HAVE AFFECTED EXISTING BUILDING CONDITIONS AFTER INSPECTION OR DURING CONSTRUCTION, GOLDIN SOLAR SHALL REINSPECT THE BUILDING ALONG WITH ANY OTHER NECESSARY CONTRACTOR AND ADJUST THE PROJECT SCHEDULE AND MAKE ANY NECESSARY PLAN REVISIONS. LEGAL DESCRIPTION: COASTAL COVES -UNIT 1- LOT 22 (OR 1950-359; 3994-1375) SITE DETAILS: FOLIO: 142380200240008 ZONING: RS-4 USE TYPE: 0100 PARCEL AREA: 11,326 SQ FT -H m ELECTRI MOUI JACKSON WAY t100' m REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY ROCC SCALE 1" 0 20'-0" LEGEND (E) EXISTING (N) NEW M METER I INVERTER D DISCONNECT DOCUMENTS PLAN SET •CALCULATIONS •SPECIFICATIONS • INSTALLATION MANUALS •CERTIFICATIONS • BUILDING PERMIT 2 OF SP DISCLAIMER: PLAN SHEET FOR REFERENCE ONLY UNLESS SIGNED AND SEALED BY ENGINEER -4 WIND ZONE LEGEND WIND ZONES ZONE SCALE: 1" = 10'-0" ZONE 2 ZONE 3 5'-11" PANELLEGEND TYP. MODULE 66.3 in. w 18.25 SF �+ mwu -2 ATTACHMENT PLAN SCALE: 1" = 10'-0" DISCLAIMER: PLAN SHEET FOR REFERENCE ONLY UNLESS SIGNED AND SEALED BY ENGINEER -2 I REVIEWED FOR CODE COMPLIANCE E �UCIE COUNTY E3OCC EXISTING ROOF CONSTRUCTION TYPE: GABLE DECK TYPE: PLYWOOD/OSB MATERIAL: STANDING METAL SEAM SLOPE = 4:12 SUPPORT TYPE: TRUSS/RAFTER ROOF MEAN HEIGHT: 14't MOUNT HEIGHT: 3"t FASTEN ERS/M OUNT: 2 MODULE WEIGHT: 41.2 lbs. TOTAL ARRAY(1) WEIGHT: 1072 lbs. ROOF ASSEMBLY FIRE RATING (UL 790%ASTM E 108). : CLASS A EXISTING ROOF FRAMING NOTES: 1. PROPERTY APPARAISER ROOF DIMENSIONS FIELD -VERIFIED WITH DRONE & SATELLITE IMAGERY. 2. NEW ROOF STANDING SEAM SPACING: 16" O.C. 3. WORK SHALL BE PERFORMED IN ACCORDANCE WITH EXISTING ROOF FIRE SAFETY RATING. EXPOSURE NOTES: BLDG DEPT DESIGN REQUIREMENT: 160 MPH EXPOSURE CATEGORY: C STRUCTURE CATEGORY: TYPE II / ENCLOSED ROOF ACCESS POINT (FIRE SAFETY): ROOF ACCESS POINTS ARE LOCATED FOR FIRE DEPT.LADDER(S) CLEAR OF OPENINGS AND OBSTRUCTIONS IN ACCORDANCE WITH NFPA 11.12.2.2.1.3 CONNECTOR ATTACHMENT NOTE: THE FOLLOWING ATTACHMENT SYSTEM SHALL BE USED AT EACH ATTACHMENT POINT ROOF ACCESS S-S! CLAMP SYSTEM POINT AT EACH ATTACHMENT POINT, ONE (2) 5/16" DIAMETER STAINLESS STEEL LAG SCREWS SHALL BE DRILLED THROUGH THE ROOF MATERIAL INTO THE TRUSS ACCORDING TO RESPECTIVE DETAIL. DETAILS. S2) INSTALLATION NOTE: ATTACHMENT SYSTEM SHALL BE CONSTRUCTED ACCORDING TO MANUFACTURER'S INSTALLATION MANUAL, �"\\\, r.E Hoo ll" .��. \•ENS. ••Fn �` • � F '* 6 Jff F NAL�\ II IIIIII\\\ ST z 15 a H z W LU U = z, U 0 3: LE mc 1,) C V N � LU �o Q a' m t Chi oho m C7 4T Z 0 cO G DOCUMENTS • PLAN SET •CALCULATIONS • SPECIFICATIONS • INSTALLATION MANUALS • CERTIFICATIONS . BUILDING PERMIT (MAINTAIN COPY ON J ITE) 3 OF S1 S-5-N Mini Top .59in .78in M8-1.25 Threaded Hole Back Leff 1.18in GENERAL NOTES: 1. S-5-N MINI CLAMP 1 • — 2. M8-1.25 SS HEX FLANGE BOLT (13MM SOCKET) 3. 3/8-24 SS ROUND POINT SETSCREW (3/16 HEX DRIVE) 4.— PV KIT 30 COMPONENTS 300 SERIES STAINLESS UNIVERSAL PV STUD K 19T mr \ i D �A � '�I ,£�-�{ t�1U oeruisxeolo� xx,o ou' own nrul I cl]E • x •� v o , a a 1 J.DJ 391 &[19 ].BI3 13 Tr B9.W M8 HEX FLANGE NUT A1_._I 4 �' d PV GRAB r Scale 1:1 Front .50in .491n .56in Right 3/8-24 Threaded Hole MATERIAL: 6061 T6 Al EST ASSEMBLY WEIGHT: 0.268 Ibs SUPPLIED HARDWARE: Clamp: M8-1.25 x 16 mm (0.216 lbs) Bolt: 318-24 x .800" (0.0345 Ibs) Setscrew (0.0170 Ibs) load tests & installation: WAW.S-5.COM 3" MOUNTING DISC ASSEMBLED CONDITION EDGE MID 3.000" 6=SERIES ALUMINUM .4 0.47' O e C (12.00 mm) Z %0 S-rJ-PV Kit j2j67" � N 3 Listed to UL subject 2703 r Q e ETL Listed to UL 1703 (2207mm)THE S-5!V EDGEGRABTM AND S-5-PV KIT TOGETHER 0.71 r0y 3ACCOMMODATE PV FRAME THICKNESSES 30-48 MM 3.00" 8.00 m) _(IF EDGEGRAB'S SERRATED L-FLANGE IS (76.00 mm) W CPOSITIONED BELOW THE STUD'S HEX NUT) AND ETL Listed Retlucin j 110 NV Mounting Disc g34-51 MM (IF EDGEGRAB'S SERRATED L-FLANGE IS Stainless Steel ONPOSITIONED ABOVE THE STUD'S HEX NUT). al PV Stud wl p GL gral Hex Nut '.t W ^7HE EMBOSSED PANEL GUIDE MAKES THE MODULE e Bevel Guide�'PLACEMENT_ EASIER. THE MOUNTING DISK IS - MULTI-DIRECTIONAL AND RAILS ARE NOT re Zip Tie Slots REQUIRED. FOUR STRATEGICALLY PLACED UNDER -DISK IT HOOKS HOOKS ASSIST IN WIRE MANAGEMENT. THE PV 0.06- WirepZ\ GRAB EARS THAT HOLD THE SOLAR PANEL IN (1.5o mm) Management PLACE ARE BROADER TO ALLOW FOR EASE OF �R■I Hooks IJ INSTALLATION AND PRECISE MODULE ICI ENGAGEMENT. L Please Note: Dimensions of both the Universal PV Stud and the Mounting Disk are identical between these two �• _ illustrations. EdgeGrabl (Not UL or ETL Listed) r�l 71 Please note: The assembly opOcn in the diagram to the right illustrates the serrated L-flange positioned below the stud's hex nut. 0.48" f"I (12.19 mm) r 0. t Hold MlnfMax (21. ) 1.18"-1.89" 30.00-48.00 mm) STRUCTURAL SCHEDULE ITEM MODEL QUANTITY S-5 Mini Clamp S-5! 105 S-5 PV Edge Grab Kit S-51 48 S-5 PV Mid -Clamp Kits S-51 57 ED 117 OF REVIEWED FOR '%��`F r,CORIa CODE COMPLIANCE/''',SS!an,no, STe LUCIE COUNTY BOCC W U Z LU m _J 3: LL au NL � aa� :3 �� l0 4-- DOCUMENTS J 1L�1 r W 0 PLAN SET •CALCULATIONS -SPECIFICATIONS • INSTALLATION MANUALS • CERTIFICATIONS • BUILDING PERMIT 4 OF S2 DISCLAIMER: PLAN SHEET FOR REFERENCE ONLY UNLESS SIGNED AND SEALED BY ENGINEER PV ARRAYS (N) TOTAL OUTPUT: 8,45OW O-String of 14 Modules + O-String of 13 Modules + O-STRING DETAIL Optimizer 0 optimizer O m0duO moduO 3UNCTION BOX (N) EQUIPMENT NOTES (NEC 201412017 & FBC 2017) INVERTER WITH INTEGRATED DISCONNECT (N) � O NI D + AC INVERTER RATINGS - SEE: SPECIFICATIONS & E2 GOA FUSED KNIFE HANDLE (N) ®E SITE CONDITIONS INTERCONNECTION FREQUENCY 60 Hz VOLTAGE UNE 112 TO NEUTRAL 120 V VOLTAGE LINE 1 TO LINE 2 240 V MIN / MAX ANNUAL AVG. TEMPERATURE 14' C / 3S C ZOOA MAIN BREAKER UTILITY ELECTRICAL LEGEND ENCLOSURE (E-I) SERVICE BREAKER n METER FUSE �"�+ TAP F GROUND UG UNDERGROUND E) O-STRING OPTIMIZER -STRING 200A (N) NEW (N-1) NEW -INTERIOR (E) EXISTING (E-1) EXISTING -INTERIOR LINE SIDE TAP INSIDE VIA INSULATION PIERCING TAPS I UG EXISTING FEEDER IF): THAN-2-AI, 3-#2/0, 1-#6 (G) AWG SERVICE ELECTRICIAN NOTE: FIELD -CONFIRM PRIOR TO WORK. 1. NEW EQUIPMENT SHALL COMPLY WITH NEC 110.26 CLEARANCES: 36" (FRONT), 30" (WORK ARROUND), 6 FT (OH) 2. NEW EQUIPMENT AND COMPONENTS SHALL BE CERTIFIED BY NATIONALLY RECOGNIZED LABORATORY. 3. LABEL THAT READS, "WARNING: THIS EQUIPMENT FED BY MULTIPLE SOURCES" SHALL BE PROPERLY AFFIXED. 4. LISTED OR LABELED EQUIPMENT SHALL BE INSTALLED AND USED IN ACCORDANCE WITH MANUFACTURER'S 5. INSTRUCTIONS PURSUANT TO NEC 110.3(B), AS RATED FOR OUTDOOR USE (NEMA 3-6P, NEC TABLE 110.28) ELECTRICAL SCHEDULE ITEM MODEL QUANTITY MODULE HANWHNQ.PEAK DUO-G5325 27 DC OPTIMIZER SOIAREDGE P320 27 JUNCTION BOX SNAPNRACK(NEMA 4x, UL50) 1 INVERTERW/INTEGRATED DISCONNECT SOLAREDGE IOOOOH-US 1 GSM or ZIGBEE Wireless Communication Device SOLAREDGE KIT OPTIONS 1 60A FUSED KNIFE HANDLE DISCONNECT BY OTHERS 1 EXPANSION 30INT: RUN <=75 FT, USE 411; > 75 FT, USE 8" EXPANSION NOTE: PURSUANT TO SEC. 352.44 (NEC), EXPANSION FITTINGS SHALL BE INSTALLED BETWEEN SECURELY -MOUNTED ELBOWS AND TERMINATION POINTS (NOT INCLUDING WYES). IF JOINT IS VERTICAL, OPEN END SHALL BE SECURELY FASTENED IN DOWN POSITION WITH COUPLING INSTALLED CLOSE TO THE TOP OF RUN WITH BARREL ALSO DOWN. LOWER END SHALL BE SECURED AT BOTTOM TO ALLOW UPWARD MOVEMENT. CONDUCTOR SCHEDULE TAG CIRCUIT CONDUCTOR SIZE DESIGN Q OCR) CONDUIT Ol PV SOURCE W WIRE-CU 2-#10 AWG 12.2 A N/A 3/4" PVC O2 PV OUTPUT PV WIRE-CU 2-#10 AWG 15 A N/A 3/4" PVC 03 INVERTER INPUT THWN-2-CU 2-#30, 1410(G)AWG 15A N/A 3/4"PVC 33 E NOT USED THWN-2-CU 2-#10, 1-#10 (G)AWG 15 A N/A 3/4" EMT 4E INVERTER OUTPUT THWN-2-CU 3-#4, 1-#10 (G) AWG 42A 60Al2PCB I"EMT CONDUCTOR NOTE: TEMPERATURE ADJUSTMENT FOR NEC 310.15(B) #12-21 amps #8-39 amps #4-67 amps #1-103 amps #10-28 amps #6-53 amps #2-92 amps #1/0-120 amps ELECTRICAL NOTES: 1. GOLDIN SOLAR SHALL FURNISH ALL LABOR, MATERIALS AND EQUIPMENT NECESSARY FOR THE INSTALLATION OF A COMPLETE ELECTRICAL SYSTEM PURSUANT TO THE PLANS IN ACCORDANCE WITH THE FBC, NEC, FHPA, OSHA AND ALL OTHER APPLICABLE CODES AND ORDINANCES. 2. ALL ELECTRICAL WORK AND RESPECTIVE PREPARATION WORK SHALL BE PERFORMED BY PROPERLY LICENSED SUBCONTRACTORS. 3. ALL MATERIALS USED SHALL BE INCLUDED IN THE PLANS AND ANY NECESSARY SUBSTITUTIONS SHALL BE APPROVED BY THE EOR. 4. ALL CONDUCTORS SHALL BE COPPER OF 98% CONDUCTIVITY. ALL CABLES SHALL BE 60OV, SINGLE -CONDUCTOR IN THERMOPLASTIC INSULATION SUITABLE FOR CONTINUOUS OPERATION AT 75 DEGREES C. CONDUCTORS AND CABLE SHALL BE NEC CLASS TYPE THW OR THWN, EXCEPT AWG SIZE #10 AND SMALLER MAY BE TW. INSULATION SHALL BE COLOR -CODED AWG #6 AND SMALLER. COLOR -CODED ELECT. TAPE SHALL BE USED ON AWG #4 AND LARGER. S. ALL CONDUCTORS SHALL BE RUN IN CONDUIT AND EXPOSED CONDUIT IS ONLY PERMITTED IN GARAGES OR OTHER AREAS ACCEPTABLE TO OWNER AND AS APPROVED BY EOR. CONDUITSHALL BE PAINTEDTO MATCH SURFACE AS REQUIRED. 6. FLEXIBLE CONDUIT SHALL BE USED FOR VIBRATING EQUIPMENT INCLUDING MOTORS AND RECESSED, MOUNTED FIXTURES AND SHALL BE SEALED WITH LIQUID TIGHT IF EXPOSED TO WEATHER WIYH A GREEN BOND CONDUCTOR INSTALLED TOGETHER AT CIRCUIT CONDUCTORS. GALV. EMT WITH SET -SCREW MAY BE USED FOR INTERIOR LOCATIONS. PVC WITH GREEN BOND CONDUCTOR SIZED IN ACCORDANCE WITH NEC 250 MAY BE USED IN UG LOCATIONS. 7. PV OUTPUT CIRCUITS ENTERING BLDG PRIORTO INVERTEER DISCONECTSHALL BE INSTALLED IN METAL RACEWAY. 8. ALL EXISTING AND CONNECTED ELECTRICAL PANELS, CIRCUIT BREAKERS AND SAFETY SWITCHED SHALL BE SQUARED OR EQUIVALENT. CIRCUIT BREAKERS MAY BE INSTALLED IN ANY ORDER THAT SUITS THE INSTALLER. ALINE BREAKER DIRECTORY OF SHALL BE AFFIXED TO PANEL. 9. HVAC CONDUCTORS, CIRCUIT BREAKERS AD FUSES SHALL BE REPLACED AS NECESSARY TO COMPLY WITH MANUFACTURER'S RECOMMENDED OVERCURRENT PROTECTION AT NO UPCHARGE AND CONDUIT AND BREAKERS SHALL BE COORDIATED WITH THE EQPT. NAMEPLATE. OTHER CIRCUITS PULLING 208-240V SHALL BE INSPECTED FOR COMPLIANCE WITH CONDUCTOR AND OVERCURRENT PROTECTION REQUIREMENTS AND REPLACEMENT SHALL BE THE RESPONSIBILITY OF THE OWNER AND ANY NECESSARY REPLACEMENT PERFORMED BEFORE GOLDIN SOLAR PERFORMS INITIALSYSTEM TESTING. PV SPECIFICATIONS MANUFACTURER/ MODEL No. HANWHA/Q.PEAL DUO-GS 320132 MAXIMUM SYSTEM VOLTAGE 1000 VDC TEMP. COEF. -VOLTAGE -0.26 %/K TEMP. COEF.- CURRENT +0.04%/K TEMP. COEF. - POWER -0.37 %/K SPECIFICATIONS AT STANDARD TEST CONDITIONS (STC) MPP POWER - Fria 3201325W MPP CURRENT - Imp 9.66A MPP VOLTAGE -Vmp 33.65V SHORT CIRCUIT CURRENT -Isc 10.14A OPEN CIRCUIT VOLTAGE -Voc 40.40V DC OPTIMIZER SPECS MANUFACTUUR(MODEL No. SOLAR EDGE/P320 RATED INPUT DC POWER 320 W MAXIMUM INPUT VOLTAGE 48 V MAXIMUM SHORT CIRCUIT CURRENT 10 A MAXIMUM OUTPUT CURRENT 15 A INVERTER INPUT VOLTAGE AT SPECIFIED INTERCONNECTION VOLTAGE 350V MAXIMUM POWER PER STRING 5250 W MINIMUM OPTIMIZERS PER STRING 8 NOTE: SOLAREDGE POWER OPTIMIZERS SHALL BE USED ONLY WITH SOLAR EDGE INVERTER. STRING LIMITATIONS APPLY. INVERTERS SPECIFICATIONS MANUFACTURER SOLAR EDGE MODEL NUMBER SE10000H-US NOMINAL POWER OUTPUT 10000 W MAXIMUM AC POWER OUTPUT 10000 W MAXIMUM CONTINUOUS OUTPUT CURRENT AT INTERCONNECTION VOLTAGE 42 A MAXIMUM DC POWER 15,500 W ELECTRICAL METALLIC TUBING (EMT) NOTES: 1. ALL EMT SHALL BE INSTALLED ACCORDINGTO NECArt. 358. 2. ALL CONNECTORS MUST BE CORROSION RESISTANT. 3. BENDS BETWEEN PULL POINTS SHALL NOT EXCEED 360 DEGREES AND ALL EMT MUST BE SECURELY FASTED EVERY 10 FT. AND WITHIN 3 FEET OF ANY BOX, FITTING OR TERMINAL POINT. 4. WATERTIGHT GASKETS SHALL BE PROVIDED AND ALL EMT COUPLINGS AND CONNECTORS SHALL BE RAIN -TIGHT OR RAIN -TIGHT AND INSULATED. S. SIZE OUTLET BOX ACCORDING TO NEC PER RUN. REVIEWED ``tlluunl ICE .`��: •SCE E OF : � :�47. RIOP•' � CODE COMPLIAMA one LUCIE COUNTY BOCC HO 0` NSF.F•P E C 1D u Z m t N m Q M N = r4r) °m T Q N �O C MMNy; MO vE OCIS `0 ,IWna rl > V W U z LU TD �LL I"I C N (n OWE V W _,4 a) � L � LL 14TO, W DOCUMENTS Y/ W J W 2 U En OZi W ul U I� r U W J W • PLAN SET •CALCULATIONS • SPECIFICATIONS • INSTALLATION MANUALS • CERTIFICATIONS • BUILDING PERMIT 6 OF E1 DISCLAIMER: PLAN SHEET FOR REFERENCE ONLY UNLESS SIGNED AMD SEALED BY ENGINEER 0 Combiner Box / Circuits / Conduit Combiner Box / Enclosures / EMT Enclosures /pUNARNINGI WA1W RNIN�G ELECTRICAL SHOCK HAZARD ELECTRICAL SHOCK DO NOT TOUCH TERMINALS THE oc coxOUCTOR9OFRU9TIMS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED PHOTOVOLTAIC SYSTEM ARE UNGROUNDED IN THE OPEN POSITION ANDMAYBEENERGGFD NEC 690.170 I Pan No. 59600497 NEC 690.35(n I Part No. 596-00588 /A\WARNING] © Building / Structure TURNOFF PHOTOVOLTAIC - - CAUTIoY AC DISCONNECT PRIOR TO �...,.� WORKING INSIDE PANEL z NEC 110.27(C) &OSHA 10 596- 0499 Pert No. 59fi-00499 L NEC 690.56(B) I Pat No 558-00350 0 DC Disconnect / Breaker / Recombiner Box �A WARNINGSMl 9611TA• ELECTRICAL SHOCK HAZARD THEDOCONDUCTORSOF1— PHOTOVOLTAICSYSTEM AREUNGROUNDED IFC 605.11.3. NEC690.15, NEC 69113(B) ANDMAYBEENERG2ED Part No. 596-00238 NEC 69D 35(F) I Part No. 596-00588 A WARNING ELECTRICAL SHOCK HAZARD DO NOTTOUCH TERMINALS TERMINALS ON BOTH DNE AND LOAD SIDES MAY BE EHERGUSED IN THE OPEN POSITION DC VOLTAGE 19 ALWAYS PRESENT WHENSCLARMODULE9 ARE EXPOSED TO SUNLIGHT NEC 690.17(E) I Part No. 596-00496 FOR PARKING DC BACKUP SYSTEMS $ Pan No. 596-OD240 IIermann.T"yton LOPC�TING WG CURRENT II� VOLTAGE' SYSTEM VOLTAGE`IIII� IRCUIT CURRENT IIII`� NEC 690.531 Part No. 596-00253 VMo 0 EMT / Conduit Raceways "(Reflective Material Required) NEC 690.31(GX3X4)1 Pan No. 596-00206 ® Inverter ® WARNING ELECTRICAL SHOCK HAZARD D AGROUND FAULTIS INDICATED NORMALLYGROUNDED CONDUCTORS MAY BE UNGROUNDEDAND ENERGIZED NEC 690.5(C) I Pan No 596-00498 NEC 690.31(1)1 Part No. 596-00590 NEC 690.541 Pan No. 596-W239 WARNING PHOTOVOLTAIC POWER SOURCE 0 Production / Net Meter A WARNING —ELECTRICAL SHOCK HAZARD IFAGROUNO FAULT IS INDICATED NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGD'ED NEC 690.5(Q 1 Pan No. 596-00498 0 Production / Net Meter (Bi-directional) CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED NEC 690.15 & NEC 690.13(0)1 Part No. 596-00613 NEC 705.12W)(3) & NEC 69064 Part No. 596-OD495 0 AC Disconnect / Breaker / Points of Connection - - • • • 1 1 Iiw • I I 240 M • 'III ' t0000W 42A IK 605.11.3, NEC 690.15, NEC 1 1 Part No. 596-0023796-00237 1 11, 1 I• N A A WARN NEC 690.521 Part NO 596 D0252 ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS .. qyY TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED " 24OV IN THE OPEN POSITION NEC 690.13(B) I Pan Na 596-00239 NEC 690.17(E) I Para No, 596 00497 TroI[Owiwx.�u,P.P�xlxxu '-, n Fvin, lNOWe SECOND SERVICE DISCONNECT ON NORTH SIDE OF BUILDING Nemxnvh P.rtixt[[a:.Im Unix �/ ¢epe,mlma nae.gavuvelovnm,n \ �� 1 w[xmmlxe[snrswlMrosvm! I MellvquvulaMsupvnNbl mseNsme,mC { MUAvuuMBFunreuRVNx•aay.wa paaxUe,pNxwaVlnuanef elxwT•Nawsl4'n) ( TNISPANELFED m�wnnuenrheNmlomaamalabxny I/ FROMINVT oArs anNO ... _ MNe SL011� RFM[IIOlW11Mxa553WID DISCLAIMER: PLAN SHEET FOR REFERENCE ONLY UNLESS SIGNED AND SEALED BY ENGINEER 0 Breaker Panel / Pull Boxes A WARNING ELECTRICAL SHOCK HAZARD W AGROUND FAULT IS INDICATED NORMALLYGROUNDEDCONDUCTORS MAYBEUNGROUNDEDAXD ENENG® NEC 690.5(O I Pan No. 595-00499 /AIWARNINGI ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 690.17(E) I Part No. 596 00497 WAiWARNING /A WARNIN.G]1 ELECTRICAL SHOCK HAZARD THE DC CONDUCTORS OP THIS PHOTOVOLTAIC SYSTEMARE UNGROUNDED ANO MAY BE ENFAGOED NEC 690.35(F) I Pan No. 596-00588 A WARNING SINGLE 120-VOLT SUPPLY - DONOTCONNECT MULTBYIRE BRANCH CIRCUITS NEC 690.10(O I Part ND. 596-00591 NEC 69D.33(E)(2)1 Pan No, 596-00244 TURN OFF PHOTOVOLTAIC pCAUTION AC DISCONNECT PRIOR TO PHOTOVOLTAIC SYSTEM CIRCUIT IS BAG NFED WORKING INSIDE PANEL NEC 705.120)(3-4) & NEC 690.64 NEC 1 TO 27(C) & OSHA 1910.145(f)(7) Part No 596 00587 Part No, 596-00499 AWARNINGDIIAUPOWER 'SOURCE • 11 SECOND SOURCE IS PHOTOVOLTAIC SYSTEM 42A NEC 705.120)(3) & NEC 690.641 Pan Na 596-MA95 240V NEC690.541Pan No.59600239 ®WARNING IxvERreRoVnVr,caxxecrlOx,m Hor ReiacA THCs ovERcu TDevw m Main Service Disconnect NEC 705.12(D)(2)(3b) I Pan No. 59600589 /A\WAI2NINM ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 690.1701 Part Na 596-OD497 WAXWARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL NEC 110.27(QI Pan No 596-00499', NEC 690.15 & NEC 690.13(B) I Part No 596-00243 CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED NEC 690.15 & NEC 690.13(6)1 Part No. 596-00613 m Main Service Disconnect / Utility Meter PURSUANT TO FLORIDA STATUE 377.705 (REVISED 7/1/2017) I, HOLLYCE HOOVER, PE (FL52666), AN ENGINEER LICENSED PURSUANT TO CHAPTER 471, CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE CODE REQUIREMENTS AND STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. N0,596-0@41 IH00 `Z�\ �.CENS'- � 1i 52M6 NFF GOLDIN SOLAR RECOGNIZES FLORIDA SOLAR ENERGY CENTER (FSEC) AS DEVELOPING STANDARDS �.O'• STAT OF FOR SOLAR ENERGY SYSTEMS MANUFACTURED OR SOLD IN FLORIDA BASED ON THE BEST CURRENTLY AVAILABLE INFORMATION IN CONSULTATION WITH SCIENTISTS, ENGINEERS AND RESEARCHERS AND '. '� 'F1 ORIOP,: DEVELOPING CRITERIA FOR TESTING THE PERFORMANCE OF SOLAR ENERGY SYSTEMS���'�`A,�D®�vv�,ss/01NA�0G°♦ MPLIANCE C®TDEg GV®T7E 9J®67 k� 0 'M Y LU c ,0, o z DI N M aM °„ 3MJaa = M o M x a Lo IT U)WO c CO N-y 0' E •O1 W IS 6 N i V LU U Z a W m.i Q I2-. V/ 02 0U LLIITS V N t' o m IE � 01 4- 0 IA .I IL ca M ce 3 C6 U LU Z U N C CONSTRUCTION DOCUMENTS PLAN SET CALCULATIONS SPECIFICATIONS • SPECIFICATIONS • INSTALLATION MANUALS CERTIFICATIONS BUILDING • BUILDING PERMIT 7 OF E2 The new Q.PEAK DUO-135 solar module from Q CELLS impresses thanks to innovative QANTUM DUO Technology, which enables particularly high performance on a small surface. CI ANTUM's world -record -holding cell concept has now been combined with state-of-the-art circuitry half cells and a six-busbar design, thus achieving outstanding performance under real conditions - both with low -intensity solar radiation as well as on hot, clear summer days. QANTUM TECHNOLOGY: LOW LEVELIZED COST OF ELECTRICITY Higher yield per surface area, lower BOS costs, higher power classes, and an efficiency rate of up to 19.9 %. INNOVATIVE ALL-WEATHER TECHNOLOGY dOptimal yields, whatever the weather with excellent low -light and temperature behavior. ENDURING HIGH PERFORMANCE l Long-term yield security with Anti LID and Anti PID Technology'] gi' Hot -Spot Protect and Traceable Quality Tra.QrN. EXTREME WEATHER RATING High-tech aluminum alloy frame, certified for high snow (5400 Pa) and wind loads (4000 Pa) regarding IEC. O A RELIABLE INVESTMENT Inclusive 12-year product warranty and 25-year linear performance guarantee2 STATE OF THE ART MODULE TECHNOLOGY QANTUM DUO combines cuffing edge cell separation and Innovative Wiring With QANTUM Technology. THE IDEAL SOLUTION FOR M W.Parms. ®PmtPpmrysm il4eraioubumv, mneNauirEam;sl buae� Engineered In Germany DISCLAIMER: PLAN SHEET FOR REFERENCE ONLY UNLESS SIGNED AND SEALED BY ENGINEER Oualityested jNm nYYtb IW aamedeow . .ea ID.40032587 I APT lest conditions according to IECITS 62804.1:2015, method B (-1500 V. 168 h) . See data sheet on rear forfuther information. QCEIIS MECHANICAL SPECIFICATION Format 66.3ma39.4ma1.26in((ndutlinghare) �• (1685 ram. 1000 mm s 32 ram) "°' Front Cover 0.131n (3.2 ram) thermally pm-sbessetl glaze wim entiaeflection tetivwla9y '. r Back Cover Composite film Creme Black oslam ' Cell 6X20 monocryelailine CIANTUM solar half�tis Junction box 2.763.35 in • 1.97-2.76 In . 0.51-0.83 in (70-85 mm a 50-70 mm .13-21 ram), decenbalaed. IP67 a .•..a.. "0i•"" Cable 4mW Solar cable; (*)a43.3 in(11 ED mm).(-) a 43.3 in(1100 ram) i� _L .. Connector MultiContect MC4, IP68 •e,. j- 1 . POWER CLASS 316 320 326 MINIMUM PERFORMANCE AT STANDARD TEST CONDIT(ORWWCOLERANCE a6 W 1-0 W) Power at MPP1 ,me A 315 320 325 Short Circuit Curmntl (At 10.04 IOD) 10.14 E e< E Open Circult Vollagel we M 39.87 40.13 40.40 a Current at MPP1 [A] 9.55 9.60 9.66 aee Voltage at MPP wee M 32.98 33.32 Sass EBlclencyl m 1%] a 18.7 a 19.0 a 19.3 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2 Power at MPP „„ N 235.3 239.0 242.8 Shod Circult Current ac [At 8.09 8.13 8.17 Open Circuit voltage voc M 37.52 37.77 38.02 f Current at MPP on [Al 7.52 7.56 7.60 voltage at MPP M 31.30 31.62 31.94 1Meawmmerd klemn., PMPP t 3 %; ISC; VOC i 5%a STC11QffiWB1C. AM 1.5 G G=Ming kEC6GJ04a P00 WW. NMOT, specown PM 1s G %CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE 5 1n At leaztga%ofnominal power during firstyeer. o = Thereaftermax0.5456deamdationperyear. d • At least 93.1% ofnonanal pawerupto l0 wen. _ ,u Atleast 85% afnombal powerupto25 years. c9 AtidatewiM1bmeasummemtoleences. w - Fullwanenles in acmNanaewlb tn.warranty terms of Ne O CELLS.rr1..manlation o(your respedha ray. 330' 330 10.20 40.66 9.71 33.98 a 19.6 246.5 8.22 38.27 7.64 3225 Typkal module peNormance under law esc lane. conditions in ennw�s,°w""....mwna u°i raw vaAas eompadsantu STOeonlWons(25-C,laeo Wrrg TEMPERATURE COEFFICIENTS Temperature Coefficient ofiSC a Ieb IKI -0.04 Temperature Coemclent ofVOC it [%I K) -0.28 Temperature Coefficient of PMPP Y r,61 KI -0.37 Normal Module Operating Tern eratureNMOT CFI 109t5.4(43t3'C) PROPERTIESFORSYSTEM DESIGN Maximum System Voltage VSYS M 1 ODD(IEC) 11000 ILL) Safety Clan II Maximum Series Fuse Rating [A DC] 20 Fire Rating C (IEC) /TYPE 1 (UL) Max. Design Load, push2 IlbaM 75(3600 Pal 155(2667 Pa) Permitted module temperature -40 T up to.185'F on continuous duty 1-40'C up to.85'C) Mac Test Load, Push / Pu112 PbsMI13 (5400 Pa) 184 (4DDO Pa) r sea installation manual UL 1703; WE Quallry Tasted; CE-complisnq Number of Modules per Pallet 32 IEC 612153016; IEC 61730:201, sppucomen easaA Number of Pallets per 63' Trailer 30 r Number of Pallets per 4P High Cube Container 26 1�f Pallet Dimensions (1. s W e H) 69.3 in s 45.31n • 46.91n i (1760 mm a 1150 mm. 1190 mm) Pallet Welght 1415 Ibs (642Ing) NOTE: Installation ksnuacm, must be lollowed. Be. me Installation and operating manual arcontecl ourtedmkel seN&e department kr Ndharb0mmlbn on eppmwd installation and use of mis pradutl H.." a CEI1S America Inc. 300 Spectrum Center Ddw, Sul. 1250, Irvine, CA 92618. USA I TEL.10491" 59 96 1 EMAIL ORu aGus4a'als.com I WEB www.ecetis.us REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY D®CC W r•1 Power Optimizer For North America P320 / P340 / P370 / M O X PV power optimization at the module -level / Specifically designed to work with SolarEdge inverters Up to 25% more energy / Superior efficiency(99.5%) 1 Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading / Flexible system design for maximum space utilization / Fast installation with a single bolt Next generation maintenance with module - level monitoring if Meets NEC requirements foram fault protection (AFC1) and Photovoltaic Rapid Shutdown System (PVRSS) / Module -level voltage shutdownfor installer and firefighter safety / Power Optimizer For North America P320 / P340 / P370 / P400 / P405 / P505 RmM IryW DC Pwxrt1) 320 U0 376 a00 405 We w p Ilde Maximum 0ryN V.ft,. W.at to Wmgermrte) aB 60 80 sae na vac MPPTOperaB,Rarbe a-4B 6-60 6-W 125-105 125-83 vs, M.,nmhS ft C1r.m0,r (lsc) 11 101 14 Pac MVImum DC lnWCurrtA 13.75 12.63 17.5 Ndc Meilmum Effide 996 % Welglrted Elsdeny 98.8 806 % OVervutlaga CEvymy it AN4G1AIIC, - M.lmum Albxed6,wxn Weise 1000 Vdc ComWeNe lmereR AT rl arEdge Srole PNSe arM Three Plane dna m Ddnenelam(WxLx N) 128 x 152 x 2815 x 597 x 1.1 128x 152x 36/ 6x 5.97x 1.42 12ax152x501 5x 6..97x 1.96 I 128xt52x5g/ 5x SW x2.M mmlh WegM(ln W,,;;,atl®) 63011.4 )W11A U5/19 1WC123 91/2, InputGmn. ONPrt Woe Type / Cameapr DDude ineulMi t MU Oulgrt Wire Lergh 0.%100 1t/09 mill InWWn,U,rMlh 0.1610.W mirt Op rstn,TempnaDn,Rap 40-.85,40- 185 P(electloll RaYry IPBB/NEMAEP RelaOxe HumlOQy 0-tOD % (1) W W STC —dw, motlm. MoaW am m✓Rpmer Wmun•k.N ('q�E� re) rN�an•mu W�4w4P hrMnvIMBN Meg q.®mrn Ba:r6de• PV System Design Using Single Phase Single Three Phase 20811TIme. Phase 480V phase WrImum btri, Un h �O, P340, P3T0, Cc1.7 8 t0 16 IPaesroptlmlmn) 50., 6 0 14 M.Irimi me,Lerph 25 25 mx P.,o 5)W I6000 wM MBFImum Pmrerper6'OBp SE)600.U8-SE114 5250 6000(T) 12)50(B) W us Pamllertioame of DlflereMtenglM Y. aroheni.mr� _ YevlvrppeplpswYrhr6EmfJ(U65E10]fUb) solaredge.coma I1 CE ROHS DISCLAIMER: PLAN SHEET FOR REFERENCE ONLY UNLESS SIGNED AND SEALED BY ENGINEER 111111111111111/zz/� ,E HOp`%, .��.Z.:: ��CENS' •.F.P * 6 /7 3 -o STATE OF P40RI�p'� REVIEWED FOR CODE COMPLIANCE STe LUCIE COUNTY Z 0 1.4 M U. N U W a W N N a �, =A Single Phase Inverter z with_ H-D-W-aveTech nology- rn- for North America N SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US / X SE760OH-US / SE10000H-US / SE1140OH-US Ise Optimized installation with HD -Wave technology / Specifically designed to work with power optimizers / Record -breaking efficiency / Fined voltage inverter for longer strings / Extremely small / Built-in module -level monitoring / Outdoor and indoor installation Integrated arc fault protection and rapid shutdown for / Optional: Revenue grade data, ANSI C12.20 NEC 2014 and 2017, per article 690.11 and 690.12 Class 0.5 (0.5%accuracy) / UL1741 SA certified, for CPUC Rule 21 grid compliance / Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE1000OH-US / SE1140OH-US OUTPUT Rated AC Power 00pat Stan) 38a6®2aov 3300 Q0208V 5000 69oa®2aov 5000®208V 7600 10000 1140M VA Maximum ACPower Output 3wo 38UU®24oV J3oo®208V 5000 80000924W sacra@208V 7600 10000 114000 VA AC0uVa1Vc1Mge Idn Nom-Max. 3 - 3 - - - Wd (183-208-no) AC OutEAVorep Mil:Nom.Nax. 3 3 3 J 3 3 ] Vaa (211-24D.264) 1 AC Fremency(NomMa6 59.3-60-60.5(1) Hz Mmhnum Contnuou. Output - 16 - 24 - - A Cured 208V Maxlmum Ccond..(XtWCur 12.5 18 21 25 33 42 473 A ent ®2aov GFDIThreshoid 1 A UOity Mandating, hdand'mg Pd l fl a CauMry Cedgurede Yea reashalds INPUT MadnOm DCPawer®240V 4650 1 5900 7750 1 9300 1 11800 1 165W 17650 W M.hnm DC P.—r C208V - Sim 1 ]750 - Trnnarorme-I. ,Ungrounded Yea Mximum IrµN VWWP 480 Vdc Nominal DC InWVoaage 380 400 We Minimum Input Current 208V(2) 9 1 13.5 - - MNimunrand Cunent@240VM 8.5 10.5 1 13.3 1 16.5 30 n no Ada Max. Input ShatCB ft Cunam 45 Me ReversePalmity Rotedbad Yee GraunbFault lealdon Detedan (WaInSenswily Maimum lmcAer EMdmry 99 Sol % CEC WdgM Etfn'e, 99 % Nighdime Power Consundtan 2.5 W �....e.,• ••"`"••`"' Aatlomatc Rapid 6hmdown upon AC Grid Dbcnnned I STANDARD COMPUANCE Odd canned. Sandar& SPECIFICATIONS AC DianaSrsa IAWG 314' mWmum/ I" AM W4' minllwm n"AM OCanduN Szelt015Mga 3/4'minmum/1- MNS/W-6AWG 3Xrd nImum/1-3adNe/1"AWG AM Range WG Range (H. MNona wiN Set* SwiW (WWxD) 17.7 x 14.6 x 6.61450 x 37D x 174 21.3x14.6x7.D1540x370x185 mm WelghtWtl, Saety Svftch =110 25.1/11A 262111.9 38.8117.6 lb/kg Nolte e25 •50 deA Coal'n9 Naodal Convection N..Icanvedon OpemSng TampenWre Rang. -13to+1401-25 to KD(4) (4GF 14D'C opod)(5) -F/'C Pmtedon Rafts NEMA0(onverteredlh Safety SVNch) ohrnpbmlNPnPPbaNw,NdSea,F�•uq{dl SIA NN6ppEamHftLSMit o)R=PM•mPmbhInTYWwNiCl3 solaredge.com IjF-dPM5 solar r 4vurrtLllsniytlpulmammSlbtotltlekvaFws2mAaM,M ee 0RnNbNRh uN obNCyi•jrtlq-atleMa9•a�.�w45OAM1N4EheeWftlaek¢. ViWptp Mtq/AFy.ErnmemM,v =h.oar.r�ne�..oa.e l.,.xwe,arm.wne.r,.,eem. a+.�w:.vmlxauaaxw "°"�: •^waswrtaaruaexple..renr swl.amwa.wann CC ROHS ij O LN r a N 'L N U W a W ce \\\\1111111111/!!! CE H001 Z N t4F1r REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY DISCLAIMER: PLAN SHEET FOR REFERENCE ONLY UNLESS SIGNED AND SEALED BY ENGINEER