HomeMy WebLinkAboutSTRUCTURAL CALCULATIONSFF3 1 5 Z019 -ST.-Lucie-County,. %,R STRUCTURAL CALCULATIONS for Solar Photovoltaic System Project: Defabio Residence Address: 913 Jackson Way, Hutchinson Island, FL 34949-8518 GSN: 1901005 INDEX Scope and Data ENV Data & Calculations Module and Attachment Loads Wind Details & Roof Zones Module Specification Attachment Detail Attachment Detail Span Table Rack Certification & Load Table PAGE 1 2 3 Al A2 A3 A3a A4 A4a SCANNED BY St. Lucie County `�gt111nuttlllq CE H00`.,,��� CENSF F� * 0 52 wc�/� STATE OF ° G; %0,<`�S . 0 R 10 s/ONA1.E '/Inn11n1110 1109 US-1, VERO BEACH, FL 32960 (772) 205-3244 permitting@goldinsolar.com Note: The Calculations are part of the Construction Documents and shall match in specifications, codes and regulations. Project: Defabio Residence No. 1901005 Analyst: Amjad Mardi Revision GOmOLAR ter' - Engineer: Holly Hoover, PE 0-- Step 1: Scope and Data Purpose: Determine Wind Loads on MWFRS Solar Equipment Method: Directional Procedure for Appertenances Reference Standards: FBC 2017 (ASCE 7-10/7-16, Chap. 26-30), NEC 2015 (Art.690), IBC 2015, HUD hr Risk Category II Table 1.5-1 he lie Exposure Category C Sec. 26.7.3 ti 1 ELEVAMON STRUCTURE DATA ABBR Bldg Type Enclosed Low -Rise <60 ft, hr < LHD Sec. 26.2 Roof Construction Gable Composite Shingle Field Survey (FS) Mean eave height he 8.0 ft FS/Eagleview 50 %eave height 4.0 ft Mean roof height hr 14.0 ft " 40% mean roof height 5.6 ft Calculated Primary Roof Slope (0) 4:12 18 deg Eagleview Parapet height hpt N/A ft FS/Eagleview Mean canopy height h, N/A ft " Building length Wt 69.0 ft " 4% building length 2.8 ft " Building width Ws (B) 46.0 ft " 10% Least Horiz. Dim. LHD 4.6 ft Calculated Dead Load D 20 psf HUD Live Load L 20 psf I. PV MODULE(M)DATA ABBR SOURCE Chord Length Lp 5.56 ft Module Spec. (A2) Width w 3.28 ft " Area A 18.25 ftz (panel : panel gap > 0.25 in) " Thickness T 0.11 ft " Weight W 41.45 lb " Low Module Edge hl 0.5 ft See: Plan Sheet S1, S2 High Module Edge hz 0.5 ft (10 in min.) " Angle to roof w 0 " (tolerance of 2°) Calculated Distance to Roof Edge = 2h2 1.0 ft (min.) Test Pressure 113 psf Design Pressure 76 psf Test Pressure -84 psf Design Pressure -56 psf 1109 US-1, VERO BEACH, FL 32960 (772) 205-3244 permitting@goldinsolar.com Note: The Calculations are part of the Construction Documents and shall match in specifications, codes and regulations. 1 Project: Defabio Residence No. 1901005 Analyst: Amjad Mardi Revision GOLUItJSOLAR Engineer: Holly Hoover, PE i Step 2-7: ENV Data &Calculations ENVIRONMENTAL DATA ABBR ASCE Source Basic Wind Speed V 160 mph ASCE 7 Hazard Tool Use per Bldg. Dept. V 170 mph -Directional-factor - - -Ka 0.85 mph Table26.6-1 Elevation factor Ke 1.0 < 1000 ft Table 26.9-1 Topographic factor Kn 1.0 Table 26.8-1 V pressure exposure K,h 0.90 Table 26.10-1 Gust effect Factor Gf 0.85 Rigid Bldg N/A Mean elevation h 14.0 ft Velocity pressure = q,=h 57 psf = 0.00256 Kr Kt Kd Vz a = 4.0 h/B = 0.3 Factors Range Equalization ya 0.40 (Figure 29.4-8) 'a"rl` �_ Array Edge -YE 1.50 Exposed (-) K ®J _ K ® A ArrayEde g -/E 1.00 All (+) Nonexposed (-) 1 I I I Parapet -/p - min (1.2, 0.9+hpt/h) 1 I 1 1 Chord '/C 3.94 max (0.6+0.06Lp, 0.8) Exposed Panel within 1.51-p 8.3 ft 1 1 I 1 Edge Distance > 2h2 d1 1.0 ft (min) I I 1 1 I 1 I 1 iSF t ® Array Separation = dZ> 4.0 ft PLAN Gable roof Determine Wind Pressures P = gh(GCp)(yJ(ya) on Array as Composite Total Modules: 26 Array Area: 474 Zone M (#) M (SF) GCp (+) GCp (-) Exposed % 1 26 374 0.3 -0.8 26 100% 2 26 100 0.5 -1.2 26 100% 3 GCp: External pressure coefficient; Table C30.3-3. Gable Roof, 7° < 0 <_20° (Figure 30.3-2B) Zone -/E (-) YE (+) -/a % 1 2 1.50 1.50 1.00 1.00 0.40 0.40 50% 50% Wind Pressure (psf) P (+) P (-) Module Design 76 -56 Effective 9 -34 Margin 67 -22 OK 1109 US-1, VERO BEACH, FL 32960 (772) 205-3244 EMAIL: PERMITTING@GOLDINSOLAR.COM Note: The Calculations are part of the Construction Documents and shall match in specifications, codes and regulations. _2 Project: Defabio Residence No. Analyst: Amiad Mardi Revision GOSOLAR Engineer: Holly Hoover, PE w Step 2-7: ENV Data & Calculations SUPERIMPOSED LOAD CONNECTOR CAPACITY Roof Dead Load 20 psf Truss Member Type SYP RooiLive Loa - 20 psf Spacing 24 in o/c Total Load 40 psf Specific Gravity (G) 0.55 Section 2 x 4 in x in Module Weight 2.3 psf Source: NDS 2015 (TR12), FBC 2017 Safety Factor 2 Connector Type Lag Screw Diameter 5/16 in Module Deadload 4.5 psf Penetration 2.5 in (min) Roof Deadload 20 psf Number 2 Live Load 0 psf Total Load 25 psf 25 < 40 OK Withdrawal Capacity Lateral Resistance (Table 12J) W = 1800 G3/2D % 307 Win 1-3/4", Z 140 lb Short Duration Factor 1.6 Group Factor (Table 11.2.6A) 0.98 lb W * SDF = 1227 lb / screw LR * GF * STF = 220 lb Total Capacity 2455 lb Lateral Pressure (max) 85 psf Uplift Pressure -34 psf Tributory Area 0.5 sf Tributary Area (TA) 12 sf Lateral Load on screws 42 lb/screw Uplift -408 lb Safety Factor 1.67 Assembly Weight/TA 31 lb Shear Force / screw 35 lb Net Tension / 2 screws 2078 lb 35 < 220 OK OK Set Chord Edge Distance (Table 12.5.1C) Set Connector Spacing (Table 12.5.11)) L/D = 8.0 psf L/D 2 6.0; 5D = 1.6 in L/D >_ 6.0; 1.51) = 0.5 in Provide 2.5 in o/c Provide 0.75 in o/c 1109 US-1, VERO BEACH, FL 32960 (772) 205-3244 EMAIL: PERMITTING@GOLDINSOLAR.COM Note: The Calculations are part of the Construction Documents and shall match in specifications, codes and regulations. 3 t.� G0 -E)IN:SOL.AR Wind Details and Roof Zones 41 - 't. BM'\ w f rVEW SpeaH" 160Vmph 25y0af MM 107Vmph soy `:&Ii 1l9 VmpM1 I 100yearMw 731 Vrnph Velu W._Ne01 3aeenlW 9ltat WW sFjeeM1a rf 3ft ,W OrcuM/ Fzppa reCCategery bazeJ M Nlepelllenbetw cvniou WIM' peeE a Nt rypl [etl Noccwtl wlOrMe]16SatgvLL WlnE peetl_i pontlt Pp NialelY ]%P babllHyoleiceed 15_OY am. J (emuele 5 preEadOry0°C193; M0.1 TER: y #) Wi ie Ina Nmkan .e rMlon eS de 1n0.CMB7-165 Ian 2kz GlazMopeMnpv Null beprotectN a8a4¢1wNdhemeEebrla aaapedaetlN - SMbn 2h123. nscr3su ],6.P1a��asia ne Ph ccz,=cc.z< _ wlb�l m ♦`I`M —M1Ubra:. i._ -_ �1brmWa Beach lj� hlmlNl �y FLP.—Cut r. Yp t ! 4 A J e ral �.a -44 Vw'tye MIRD 2D11E LEGEND WIND ZONES ZMEI SCPIP3 V = ZD'-Ir O ZME 2 O ZMEI 1109 US-1, VERO BEACH, FL 32960 (772)205-3244permitting@goldinsolar.com Note: The Calculations are port of the Construction Documents and shall match in specifications, codes and regulations. Al GOLDIN:SOLAR MODULE SPECIFICATION wade' �e7k8 -- _ __ kontterei-v- -- —72 run 4.eroll�prc4c_ed FJas with -- -- _._—_ af'7e/:rstim rcchrobp)_ __—_ I Paco Corer Canpcite (3r.I frame Btx4 saacrcrs! aaanvvam Cefl-----6x Zll maocuv-_eilline OAN1Uf1 solar Ealf cdL• - — 5 � OFeaClrcahYaltaQe'— _ � C¢Oenlat NPP vmra¢eat ]aPP aWlitllP!PFRTORYANC7 AT iPailerattePPr v f1--se`or.ilsolt tiireor I O,x�a prcoltYoluee- carieola�ePa ANOAPO7O5T CONCTIIONS.STC'I iDt[PANCTYaW/-OY/) Im P� IYl1 315 320 325 330' j I:i EA] 10.04 10._0920.14 1020 V. M 3997 40.13 40.4D Ir r W 955 9I 9.GG 971 vw M 32,98 3332 33.G5 33.98 7 1Y61 SIIi7 219.0 �— a193 a19.6 iRa1AL GPERATIMG CONDITIONS, NOV . PY, On 233.4 2372 - _ _ 240.9 _ 2/.4.G ; Ys M_ 3730 37.54 3779 38.04 � Ier W 7.51 7.56 7.60---_-7.G4 YPS....__m 31.07 3139 31.70 32.01 '•Ymaevmn c4rans5TC a]Z:N:aaSi �bnaM.lN, Aa�Aapc¢Yn AY 15C •�pealncq aav�asmry Cma ^ NIT, CTRFORYANCg A7 LDW JRRADIAN - At1�992n1 ma1nalPberalfeP C.. __r��_,._�_ i 4et7�a9a Fvjcr.Al Ie5931ZG noaTY Pora_W b:OyaS Al lcS o — �_�__�.; eAao amWlptraa upm2Aycr-- � ; ; ; ; Fe ouwa_nma�raamtixcrncG 7 � r�� r____t__ti____.I 1 Fue9]tno9G In xmmrsoNmtx 7 � ; i ;. I aremnry asizcr ticaC[1L491� . 1 agtm�maym rcFeCvauvnlry. >a a e e ® I naaaua¢rotra T -ERATUPECOCTnCCilrtS 1> Teq^enm_re CcelflGeotlNL P p Tllgtramre CaeflmmtlN Po,_ Y_.a! rypca mx-�eprnvmmmumabomalmcnvnmeasb m.�,.vlccn m me cenwaspaXItaxrcrmcl I rA) ill ♦0.7. iempenmre [oetndeot4lva 6 I9VN1 -028 rAl _037 ^_Noma] Operating Cell_Te peramre NOCr^. 11c1- 45 Gil 20 fUe RaOag C [Pal 5400r4000 7era10l00a0ole Temptamre 40•C Lp ea.Bs'C j IWfG In••wlLna1144n=cm mlmt ro"Ma aNtw In vxn am: Cfa il. ➢iamlam O:l wimt4.1.@ptrim`.t im l7tlra1.tznc ..Maca ImJaWon aW=Wt1MF,oc I 1109 US-1, VERO BEACH, FL 32960 (772) 205-3244 permitting@goldinsolar.com A2 Note: The Calculations are part of the Construction Documents and shall match in specifications, codes and regulations. N 0 O C In N m 0 O Ip D n 2 T r w N LD 0) O 3 D w SNAFNRAOC SERIES COD RACIONG SYSTE14 TYPICAL ROOF LAYOUT NOTES: - STANDARD LAG BOLT SPEC ASSUMES 5116' LAG BOLTS WITH 25- EMBEDMENTIN ROOFSTRUCTURAL MEMBERS/RAFTERS -TORQUE ALL(G°HARDWARE TOTHE FO.LOWU.G: - SILVER S.S. ID 16 FT-LBS - BLAIX S.S. 7.9 FT-LBS RAILCAN MOUNT TO EITHER SIDE OF POST (UPSLOPE vs DOWNSLOPE) - FOR UNEVEN ROOF SURFACES, USE UP TO TWO LEVELING SPARS PER L FOOT OR STANDOFF. SEE DRAWING 'STANDARD RAIL LEVELING' FOR DETAILS AND LIMITATIONS •RAILSPAN' DISTANCEBETWEEN ROOF ATTACH HEN13 RROOFRAFTERS OR STRUCTURALMERBERS 9NAPURAOC MODULE MID CLAMPS 'RAIL END OVERHANG' (MOTTO EXCEED M% OF ACCEPTABLE RAIL SPAN 1 (NOT TO EXCEED 30% OR MANUFACTURER'S RECOMMENDATIONS) DES rc&lNeuTek nlA.^ St00D(6 SER�SIODTYPICALlATOUf F fv I WIC 130113 �� !J'IYm'ICDtlT. GO<C�Dsl„WSQLAR ATTACHMENT DETAIL BASE FOR PLANE 1-3 (COM jPOSITE SHINGLE) - Y T @ �v Ot 44 cn®tr'>cvas.c4s gwnrMx.+aJranMtq Nu+v.ti.e.mn++ Q 1 .e—n... RS'A �tAS=�j -4011 tt.Yh [[G.4Cmm Et F"w QFL-"2 F[uMng EaoFasten LAU4 m2h [All r- i O9 1109 US-1, VERO BEACH, FL 32960 (772) 205-3244 permitting@goldinsolar.com Note: The Calculations are part of the Construction Documents and shall match in specifications, codes and regulations. A3a GO DL - IN�SOLAR s RACK SPAN TABLE • v_: •i7 r> •F F•_ } }i MI Lp_FYkitl '•}_•• 4]••••i\_FO_F •iF:•FF: Fd-GF_Ft}i.a:tti . F_: :' it :t `•} 929E a_eSv• a 1, 1 +•ateC- .p: _ _ •amFea_,tl • •Y ap9Ca5• i+.p+m tl+[p9p[•me ua•fmn'a. a i•:}[a:I d i[A: :F}a':Fv :mFFv[:itla :p: iiA:ip: �a� •i_.•_ }vp::Gai:G: P :C2-'idt : e=`}i:•:!:•iF+ Ft-t - 7�- 9:t •F: __ _ .}t. ii: L}FL__ 'f F: FFGit: :it: :G• FL 1 Bt:.L .f:i; LGA. :Y' ee_ G C. :•: iC:•: • :•::L :LLS :• • :t : •iL [ G N y Oeam� amP[a•[ •pi •ac+cOva •CPnlG:mlain>aC+mavam:•mmFapa.` mC earc/c - at} >7F>GFtr /i lip%ti-.n aa>FF+aFta FFL t tFe:._[•ae:"MN-1211 +...•1F+.4-_ iics • Ap EFi- -343 _ _Rie ••c'e t!a• . i• _ N 2 t755tF' :}• !iF9ZZ,Me F.t a?glGti pi mYmumr__•.Y•-�tl _vtl _-+ -me[:m._:PP•:ev:• A. - i -m •_ u YCGe;�rne� ra 1cFi ' :OpY•a:2i8i•[ •Ic:cSmeGvm \m :.a:eS+:lPl ;••t._aG$. 2ypp. :pC2a_ :•:a�1a.:>•: op:xi:l ION-! .Q#- S+tl[°.•. !YOm.x0_:�_+.9G -f tr�\ipi+Y:+ amLi A.Q:S:oA Liii _ _it Fti F:__.9:ii t' L:xiF9•Fti :9: '.GOaae _ii }CL'.:_�tEtiti: C S Atl i0:-1 GE[Qc i aSimaatl5 :+a MEQ& !++[°aa pPf•_ m .:m2 •it ev A cF k. p: +G: •1 :2. :Om. i cq.i\12204-10 S!am.G2.laaPaSS+•_ifa!\alG>m0. a+1:Nm2Sll +f ili ..MM. 294 .0 }++ FFG4a.pe•\a\ ;aA cm_a aAm }1. Tx :mv5 :5e: loan :e0 :1lOS'ipe3- :33 SOVE 9c:'Gca! ii wvaI p+eal+cei: Patlr\::••miilf vi +l +mG+Y. -Y+aeaeaeep•.vvr.k + tom 1111111-121 3: .... 1 MIN rl�v•evm aGvaa+vireac alialva[vva•.pe •eac-acaeeai/ee\ v>a•aa..e.i � �S9'ESk.'•.�`•:.. .-iE: L...:3. ....t4.L .5...4 .. 3L.•:S: 4:•4:n C cQ [rveYvelcv0.8 PI>fY�[ea0`anmFipe.lnpxvP..lve�/ea0 e0G Spa>peeGs>>iea aF La _Lain::•:- �.LOiFi: !;,A.Gyi°LYCit•�it 5_•c <_i F [a -a a !st_ • ! itx !• ! x _! �:�i��Vi°�Vi i 1SI188f !! !Q + _: a _ CCC i i SaFFatiia" iztFi�Gkia o♦Lihiaik i�GiaGatki=i6'aGL'v W h M vh i•iiai5i t aL=akv hi' 4i 1109 US-1, VERO BEACH, FL 32960 (772) 205-3244 permitting@goldinsolar.com Note: The Calculations are part of the Construction Documents and shall match in specifications, codes and regulations. A4 HE MUM M311:1,29,20211 swfirA 77SFMLax,Sic200 San LdsOK:;O.CA93t01 1LL1877)711.21160 Atba:SnaPNrad •[t�mleerhg0epxmers kdb)e Report a 2017002ZOCM- SMOVadSeries 200SOW FhotwntsleRadhgSystemwlh6005-ISR34 P61. In, -Strumml Dowatts har bean reSNef te, pmdde croveNg services rda:ed b She LwArad Scrb IW Raekle;System. 1Faatndedspws WReseprwkdF«thee a0ryrU05 alunlnantal4whhwlmnsNemdondUn r«ercabn«attadmmldnkcs. Ffgum L•Stobn9kwdSeries 100rAshwa'ng Overall doreralomandtkalumkumduvdrutr. lhhkhvw&ks LIM theaitadcd spanWNe am to celndhncewdhthebtlldngodeandiedodenmpr maedin PZS( Report a 2017*240 Cal. DIG1TALlY SIGV-cD IlyvuhmonryAsctkro,neeothedhmla tal svvuvV`IK OZIrAnyr r6j/' Pena, ttdlry: P151,L2c-StuevaSDy-b«ns _ = RoxrDe,CA 5TATEOaF Or-' AL Al'nsl" BISOS9rta Calogo Belerrrd Olga ISO. 9owla ugS661 191061]7o) t 91d.91IJ269 W wwworagorn Ily D:ro • 1 s -^— I San 1,11 AttadunenthsRooh. The attached span tables Indu de conLdemtbn of the attachment device UPadry, based on U L 2103 bad testing pedomaedby SnapNmdc Tested loadvalues are devebpedwith 5/16'0lagscrevn,withaneffecWeembedmemofl• 2/2'Intoa Douglas Fbsubsvaw,withareferencewithdrawal(uPNtorpAoset)bad'u cityofS32Ib,andareference shear(sbe mlalemQ load mpadtyof270m for resisting short-term Wnd«xk ipnieads. Referencavaluesarelhe baxvalues,befommyadjwtmentismdeparlhe NDS. WtalWUominwaltem tc substmtMorwNchusealternate fastenersshe0 bepermdtted; provided Uutthe tastenerhas tested croadededved allaaableloadcapacities,and mecU one of the fdlovMg two of tech: A) The allowable bad values for lM alternate fastener shall meet «e+ceed the allmbleYA" noted above f«the 5116, 0lag screws in Douglas Fir; «B) thespan length Wentifled in the'span tables'shall bareduced aoonding to the more resuktiveof thefollowblgtwo formulas: Ralf Span a TableSpan. Alrermre Reference IYlthdrawl Capacity 5321b Or Rail Span - Table Span . Altemate Reference Shear Capacity 270lb These formulas Shall net be used to Increase the allowable span beyond the spans fated In the span tables. Attachment Devimc The span tables haw been grouped Into sepamtesets ofattachmemdevices aued'Sire, wNdrare presented below. To use this table, find the attachment dMce to be used In the Est below, then read across to determine which bin the attachmentisin The span may then be determined from thetabiewilh the comespondng Bin amber. Strunuml deu0sfor thespitem and attachmentsmaybe loud In AppeMoG Note: Side loaddlreNm U parallel to roller. Table 1:Allmableload Capacities of Snpfirad F1uskrMountAtuchmenl DOOM 8I50 Scm Wow Balaverd SWo 150. Rowrao, CA96661 1 916.9613960 m 916.961.396S w procom f :f tar — 1 1 F10",rv.o wwnn�ry,:r AltaNment Ocvice Name: (lln No. Madmum RmNonlopds Dawn UD Side Standard Base Seam Clamp with L•Foot Wide Dam Scam ClamDwiN LFoot I 235 235 III UnNcnalTOe Hook I PolTilc Hank 2 394 318 417 Na�cr Bdl[tamp Hashed L•Foot(9i Deg) 3 1469 309 ISi TdaAeDbCerment 4 1333 669 93 AB Purymal•iWt(90 Deg( Umbrella Caret, pt Corrugated Straddle Blod with L FootMe WI Roof Box withL•Foot S 78B 405 x Metal goal BawdN)b Standoff I36 5•I/21n Standoff on 4-Hole Box 71n HD Standoff on 6• Nolc Box 5.1/ZIn, Tin, ore•1/1' Standoflon 1-Hole Oase 8•Il2ln Standollon4NokBase 6 788 i 045 163 D A d rD