HomeMy WebLinkAboutCERTIFICATION - DESIGN LOAD COMPLIANCEj+- = Planning & Development ces De artment
RECEIVED
Building & Code Reg i n Di
2300 Virginia Avenue, Fort Pierc1 f 72) 6 o DV 2019
ST. Lucie County, Permitting
Certification for Design Load Compliance
Project Name: /
Project Address: �w12- -4 ,r)(911 1,A)o� o0t �A /Q __ /'W
Permit#: Occupancy Type: Construction
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the f - II wing:
o New Residences (single or multi -family) cggfv�©
o Residential Addition BY
St• Lu
o Any accessory structure requiring a building permit W e CDUnty
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida 2017 Building Code Fifth Edition with 20 N/A Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed _Partially Enclosed ' _Open
3. Risk Category: _I X II _III _ IV Exposure Category: _B X C _D
4. Design Wind Velocity 160 mph X ASD _LRFD End Zone Width: 6 ft
S. Mean Roof Height _ _ft Roof Pitch: 6 :12 Parapet: N/A ft
6. Components &Cladding Des,gq Pressures Used, (PSF based on 10sgft @ 15'MRH, clearly label on all plan openings):
.jyp,Q -1ll.0 W20,6 +3y,'} 4-151,-' ti-Lf.S
Zonel: -3/.I Zone2:-ss,3 Zone3:-f/, Zone4:•-3 ,6 Zone 5:-`16,5, Garage: -_7Y,Y
7. Design Loads: Floor. 100 PSF Roof/Dead: 12 PSF Roof/Live: 30 Balcony: N/A PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF
8. Were Shear Walls Considered For Structure? Yes Not Applicable Explain Why Not:
IF42I;LI: 2 V19 G V- /
9. Is A Continuous Load Path Provided? XYes _Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2500 /v PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specifi
Oc,JA- I o% J A)L)e, �e L r� 1/6
Print Name Cert # & Co. Cert Auth.
i163�t su," /1OadG�l� S dsi ed� 7
Si , Date,'aii L6K%i 6�_
Company Name & Address
t ro /7 _
Revised 07/25/2 14