Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFILE Copy FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: MW-03 RECEIVED B ilder Name: GHO HOMES Street: 9627 KNOLLWOOD LN P rmit Office: ST. LUCIE COUNTY BLDG DPTMT City, State, Zip: FORT PIERCE, FL , 34 51 P rmit Number. Owner: FEB 15 Z019 Ju'sdiction: COO Design. Location: FL, .Fort .Pierce C my:. ST.. Lucie (Florida Climate Zone 2 ) ermitting 1.'.New construction or existing I'lew (From Plans) 9. Wall Types (2422.7 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.0 2127.10 ft2 b. Frame - Wood, Adjacent R=11.0 295.61 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4.-.Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (2389.0 sqft.) Insulation Area No 5. Is this a worst case? 3 a. Under Attic (Vented) R=30.0 2389.00 ft 6. Conditioned Floor area above grade (W) 2389 b. N/A R= ft2 Conditioned Floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft' 7. Windows(443.7 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 800 a. U-Factor: Dbl, U=0.62 443.71 ft2 SHGC: SHGC=0.26 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: - a. Central Unit 48.0 SEER:16.00 -­c. U-Factor: WA ft2 ,. SHGC: 13. Heating systems kBtu/hr Efficiency - d. U-Factor: N/A ft2 a. Electric Strip Heat 29.5 COP:1.00 - -,. SHGC: a'. F.rea Weighted Average Overhang Depth: 0.000 ft. re_a Weighted Averege SHGC: 0.260 14. Hot water systems Jcbr Types"(2389.0 sqft.) Insulation Area a. Electric Cap: 50 gallons EF: 0.900 ,- a..Slab-On-Grade Edge Insulation R=0.0 2389.00 ft' b. Conservation features - b. WA R= ft2 c. N/A R= ft- None 15. Credits Pstat Glass/Floor Area: 0.186 Total Proposed Modified Loads: 76.47 PASS Total Baseline Loads: 78.33 I hereby certify that this calculation are Code. PREPARED DATE: I hereby certify with the Florida OWNER/AGENT: DATE: the plans and specifications covered by Review of the plans and compl' a with th Florida Energy specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 this-bei din a designed, is in compliance Florida Statutes. rg BUILDING OFFICIAL: DATE: b - Compliance requires certifcaaon by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. 1 • - Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 1/17/2019 10:39 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT ; PROJECT Title: MW-03 Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2389 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: GHO HOMES Rotate Angle: 0 Street: 9627 KNOLLWOOD LN Permit Office: ST. LUCIE COUNTY BLDG D Cross Ventilation: No County: ST. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL 34951 - New/Existing: New (FromPlans)- Comment: CLIMATE •,./ Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 2389 22217.7 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfI ID Finished Cooled Healed 11 Main 2389 22217.7 Yes 4 3 1 Yes Yes Yes FLOORS y # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 215.9 It 0 2389 ft2 __ 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Barrel tile 2672 ft2 0 112 Medium 0.4 N 0.9 No 0 26.6 ATTIC / ' y V # Type Venlila6on Vent Ratio (1 In) Area RBS IRCC 1 Full attic Vented 150 2389 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 2389 ft2 0.1 Wood I t. i 1/17/2019 10:39 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below mt-T� wap_Type S Space R-Yalu Fr to Fr in Area R-tr-Iue_F_raction--Absnr Grade _ 1 N Exterior Concrete Block - Exl Insul Main 4 58 2 9 4 542.9 ft' 0 0 0.3 0 -2 E Exterior Concrete Block - Ext Insul Main 4 61 0 9 4 569.3 ft' 0 0 0.3 0 -3 S Exterior Concrete Block - Ext Insul Main 4 32 0 11 4 362.7 ft' 0 0 0.3 0 -4 SW Exterior Concrete Block - Ext Insul Main 4 2 11 11 4 33.1 ft' 0 0 0.3 0 -5 W Exterior Concrete Block - Ext Insul Main 4 55 11 9 4 521.9 ft' 0 0 0.3 0 8 NW Exterior Concrete Block -Ext Insul Main 4 8 7- 11 4 97.3 ft' -0 0 0.3 0 " 7 - Garage Frame - Wood Main 11 26 1 11 4 295.6 ft' 0 0.25 0.3 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Wood Main None .39 3 8 24 ft' WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 n 1 Metal Double (Clear) Yes 0.62 0.26 N 43.3 ft' 0 ft 0 in 0 ft 0 in None None 2 n 1 Metal Double (Clear) Yes 0.62 0.26 N 112.4 ft' 0 ft 0 in 0 ft 0 in None None 3 n 1 Metal Double (Clear) Yes 0.62 0.26 N 31.6 ft' 0 ft 0 in 0 ft 0 in None None 4 n 1 Metal Double (Clear) Yes 0.62 0.26 N 6.5 ft' 0 ft 0 in 0 ft 0 in None None 5 e 2 Metal Double (Clear) Yes 0.62 0.26 N 21.3 ft' 0 ft 0 in 0 ft 0 in None None ggg y r 6 e 2 Metal Double (Clear) Yes 0.62 0.26 N 43.3 ft' 0 ft 0 In 0 ft 0 in None None [ 7 a 2 Metal Double (Clear) Yes 0.62 0.26 N 9.0 ft' 0 ft 0 in 0 ft 0 in None None - _ 8 s 3 Metal Double (Clear) Yes 0.62 0.26 N 48.0 ft' 0 ft 0 in 0 ft 0 in None None _ 9 s 3 Metal Double (Clear) Yes 0.62 0.26 N 8.0 ft' 0 ft 0 in 0 ft 0 in None None 10 s 3 Metal Double (Clear) Yes 0.62 0.26 N 8.0 ft' 0 ft 0 In 0 ft 0 in None None 11 s 3 Metal Double (Clear) Yes 0.62 0.26 N 15.0 ft' 0 ft 0 in 0 ft 0 in None None 12 sw 4 Metal Double (Clear) Yes 0.62 0.26 N 16.0 ft' 0 ft 0 in 0 ft 0 in None None 13 w 5 Metal Double (Clear) Yes 0.62 0.26 N 21.3 ft' 0 ft 0 in 0 ft 0 in None None 14 w 5 Metal Double (Clear) Yes 0.62 0.26 N 6.5 ft' 0 ft 0 in 0 ft 0 in None None 15 w 5 Metal Double (Clear) Yes 0.62 0.26 N 12.0 ft' 0 ft 0 in 0 ft 0 in None None 16 nw 6 Metal Double (Clear) Yes 0.62 0.26 N 20.0 ft' 0 ft 0 in 0 ft 0 in None None 17 NW 6 Metal Double (Clear) Yes 0.62 0.26 N 21.4 ft' 0 ft 0 In 0 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation -- 1 1012.68 ft' 1012.68 ft' 64ft 8ft 1 -- i 1 I X 1/17/201910:39 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000295 1851.5 101.64 191.16 .224 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1. _Electric Strip. Heat/ _None. COPA 29AB. kBlu/hr 1_ sys#1 _ COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unil/ Split SEER: 16 48 kBtu/hr 1440 cfm 0.7 1 sys91 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.9 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Carl # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft' DUCTS �/ --Supply— V # Location R-Value Area Return --- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT ON RLF HVAC# Heat Cool" 1 Attic 6 800 ft- Attic 777 ft' Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Progremablre �Thermostar[t:'jY • HOct eating l J Jan l l FeDec b Mar VenOng l 1 Jan l 1 Feb X Mar CAprrralling Fans: IMarrXT� r[r` rr[[ rrXr Sepr Apr [ May [ ] Jun rl Jul 11 Aug [ ] Sep Oct Nov H Nov H Dec 1/17/2019 10:39 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM fib 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft' 0 ft 0.3 Main Name: Rating Compant: Signature: Date: 1/17/2019 10:39 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 5 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12.Ducts; location 8 insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 u 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 48.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2389 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.620 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.260 14. Heating system: Capacity 29.5 c) Area 7c. 443.7 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-faclor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other ' 9. Floor type, insulation level: - a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.90 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.0 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11C. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Address of New Home: Date: / 1 181 I I City/FL Zip: FORT PIERCE, FL 34951 1/17/2019 10:39:09 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 1 of 1 -�- wrightsoft' Load Short Form Entire House For: MW-03 9627 KNOLLWOOD LN, FORT PIERCE, FL 34951 Job: Date: Dec 05, 2018 By: Htg Clg Infiltration Outside db(°F) 43 90 Method Simplified Inside db (OF) 70 72 Construction quality Tight Design TD (OF) 27 18 Fireplaces 0 Daily range - L Inside humidity (%) 30 50 Moisture difference (gr/lb) 0 68 HEATING EQUIPMENT Make Trade Model AHRI ref ,'Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 8.6 kW 29480 Btuh 17 OF 1550 cfm 0.048 cfm/Btuh 0 in H2O COOLING EQUIPMENT Make Carrier Trade 16 SEER PURON AC Cond CA16NA048"'•A Coil FV4CNB006 AHRI ref 4585139 Efficiency 14.0 EER, Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 16 SEER 32550 Btuh 13950 Btuh 46500 Btuh 1550 cfm 0.045 cfm/Btuh 0 in H2O 0.73 ROOM NAME Area (ft') Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) MASTER SUITE 405 5908 5157 281 232 HER WIC 86 1236 754 59 34 HIS WIC 44 47 242 2 11 GREAT ROOM 441 5194 5680 247 255 DINING 159 3030 2960 144 133 FOYER 57 1270 1019 60 46 NOOK 142 2577 2859 123 128 KIT 164 172 1677 8 75 BED 2 184 1889 2650 90 119 BED3WIC 33 1062 635 50 28 CABANA 76 2111 2385 100 107 BED 3 243 2219 2836 106 127 BATH 2 59 1034 1007 49 45 UTILITY 49 52 673 2 30 MECH 34 414 614 20 28 A 111, 7711 1/ 9C7 IVIMJ I Cm GMI rI LII YV/J VV/a GVV IVY Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ti Wii htscfC 2018-Dew710:49:12 A= g Rig htSuile® U nlversal 201212.1.05 RSU02818 page 1 ) .� C:1UsersVasonlDomments\WrightsoR HVACIMW-01rup Calc=MJ8 Front Door laces: S Entire House 2386 32594 34526 1550 1550 Other equip loads 0 0 Equip. @ 0.95 RSM 32800 Latent cooling 12935 �Tni c. 1 neoc 1 cn, I evToc 1 I ,ccn V If1LJ GJVV JLJJY TJI JJ IJJV IJJV Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Deo-07 10:49:12 c wrightSoft' RlghtSuiteW Universal 201212.1.05 RSU02818 page 2 AM C:1UsersUasonlDowments\Wrlghtsoft HVACXMW-03.mp CaIc=MJ8 Front Door faces: S +�- wrightsoft Project Summary Entire House Job: Date: Dec 05, 2018 By: For: Notes: MW-03 9627 KNOLLWOOD LN, FORT PIERCE, FL 34951 Design Information Weather: Vero Beach, FL, US Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 90 OF Inside db 70 OF Inside db 72 OF Design TD 27 OF Design TD 18 OF Daily range L Relative humidity 50 % Moisture difference 68 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 26835 Btuh Structure 27408 Btuh Ducts 5759 Btuh Ducts 7118 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 32594 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 32800 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Tight Fireplaces 0 Structure 10615 Btuh Ducts 2320 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft) 2386 2386 Equipment latent load 12935 Btuh Volume (ft) 24178 24178 Air changes/hour 0.11 0.06 Equipment total load 45735 Btuh Equiv. AVF (cfm) 44 24 Req. total capacity at 0.70 SHR 3.9 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade Trade 16 SEER PURON AC Model Cond CA16NA048""A AHRI ref Coil FV4CNB006 AHRI ref 4585139 Efficiency 100 EFF Efficiency 14.0 EER, 16 SEER Heating input 8.6 kW Sensible cooling 32550 Btuh Heating output 29480 Btuh Latent cooling 13950 Btuh Temperature rise 17 OF Total cooling 46500 Btuh Actual air flow 1550 cfm Actual air flow 1550 cfm Air flow factor 0.048 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.73 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. r wri htsoft 2018-Deo-0710:49:12 g RightSuite® Universal 201212.1.05 RSU02818 Pagel C:\Users\Jason\Dowments\Wrightsoft 11VAC\MW-01rup Calc=MA Front Door faces: S MASTER F COVERED SUITE u1Na HERS 6'0 1 0x10x7 116 CFM GREAT ROOM k1� 10x 10 x7 11.0 128 CFM 7'0 \\`II 6z6 10x10x7lll 125 CFM 46 CFM ® FOYER 50 CFM 4 EXHAUST ASTER COVERED BATH ENTRY NOOK 10x 10 x7 128 CFM 7'0 7.0 127 FM 127 CFM 10x 10x7 133 CFM UTIL 6a CF 3CF DINING 7'0 5'0 4.0 DRYER EXHAUST e 5'0 NOTE: ALL RETURNS SHALL HAVE DIRECT DUCTING TO RETURN AIR PLENUM BOX. DO NOT SCALE PLANS KIT Bx8x6 AHU-1 lox 107 2 x10x7 19 CFM 1'0 7'0 1oxlOx7 1 127 CFM BEDROOM 3 BATH 6x6x4 45 CFM m11 Ru a sm • .0 2 CAR GARAGE ON