HomeMy WebLinkAboutENERGY EFFICIENCY CODEFILE Copy
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: MW-03 RECEIVED B ilder Name: GHO HOMES
Street: 9627 KNOLLWOOD LN P rmit Office: ST. LUCIE COUNTY BLDG DPTMT
City, State, Zip: FORT PIERCE, FL , 34 51 P rmit Number.
Owner: FEB 15 Z019 Ju'sdiction: COO
Design. Location: FL, .Fort .Pierce C my:. ST.. Lucie (Florida Climate Zone 2 )
ermitting
1.'.New construction or existing I'lew (From Plans)
9. Wall Types (2422.7 sgft.) Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior R=4.0 2127.10 ft2
b. Frame - Wood, Adjacent R=11.0 295.61 ft2
3. Number of units, if multiple family 1
c. N/A R= ft2
4.-.Number of Bedrooms 3
d. N/A R= ft2
10. Ceiling Types (2389.0 sqft.) Insulation Area
No 5. Is this a worst case?
3
a. Under Attic (Vented) R=30.0 2389.00 ft
6. Conditioned Floor area above grade (W) 2389
b. N/A R= ft2
Conditioned Floor area below grade (ft2) 0
c. N/A R= ft2
11. Ducts R ft'
7. Windows(443.7 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Main 6 800
a. U-Factor: Dbl, U=0.62 443.71 ft2
SHGC: SHGC=0.26
b. U-Factor: N/A ft2
12. Cooling systems kBtu/hr Efficiency
SHGC: -
a. Central Unit 48.0 SEER:16.00
-c. U-Factor: WA ft2
,. SHGC:
13. Heating systems kBtu/hr Efficiency
-
d. U-Factor: N/A ft2
a. Electric Strip Heat 29.5 COP:1.00
-
-,. SHGC:
a'. F.rea Weighted Average Overhang Depth: 0.000 ft.
re_a Weighted Averege SHGC: 0.260
14. Hot water systems
Jcbr Types"(2389.0 sqft.) Insulation Area
a. Electric Cap: 50 gallons
EF: 0.900
,-
a..Slab-On-Grade Edge Insulation R=0.0 2389.00 ft'
b. Conservation features
-
b. WA R= ft2
c. N/A R= ft-
None
15. Credits Pstat
Glass/Floor Area: 0.186 Total Proposed Modified Loads: 76.47 PASS
Total Baseline Loads: 78.33
I hereby certify that
this calculation are
Code.
PREPARED
DATE:
I hereby certify
with the Florida
OWNER/AGENT:
DATE:
the plans and specifications covered by Review of the plans and
compl' a with th Florida Energy specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
this-bei din a designed, is in compliance Florida Statutes.
rg
BUILDING OFFICIAL:
DATE:
b - Compliance requires certifcaaon by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
1 • - Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
1/17/2019 10:39 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
;
PROJECT
Title:
MW-03
Bedrooms: 3
Address Type: Street Address
Building Type:
User
Conditioned Area: 2389
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
GHO HOMES
Rotate Angle: 0
Street: 9627 KNOLLWOOD LN
Permit Office:
ST. LUCIE COUNTY BLDG D Cross Ventilation: No
County: ST. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip: FORT PIERCE,
Family Type:
Single-family
FL 34951
- New/Existing:
New (FromPlans)-
Comment:
CLIMATE
•,./
Design Temp
Int Design Temp Heating Design Daily Temp
V Design Location
TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39 90
70
75 299 62 Low
BLOCKS
Number
Name
Area Volume
1
Blockl
2389 22217.7
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfI ID Finished Cooled Healed
11
Main
2389 22217.7 Yes 4
3
1 Yes Yes Yes
FLOORS
y #
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 215.9 It 0
2389 ft2
__ 0 0 1
ROOF
Roof Gable Roof
Solar
SA Emitt Emitt Deck Pitch
V #
Type
Materials Area Area Color
Absor.
Tested Tested Insul. (deg)
1
Hip
Barrel tile 2672 ft2 0 112 Medium
0.4
N 0.9 No 0 26.6
ATTIC
/
' y V #
Type
Venlila6on Vent Ratio (1 In)
Area
RBS IRCC
1
Full attic
Vented 150 2389 ft2
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
2389 ft2 0.1 Wood
I
t.
i
1/17/2019 10:39 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Below
mt-T�
wap_Type
S
Space
R-Yalu Fr
to Fr
in
Area
R-tr-Iue_F_raction--Absnr
Grade
_ 1
N
Exterior
Concrete Block - Exl Insul
Main
4 58
2 9
4
542.9 ft'
0
0 0.3
0
-2
E
Exterior
Concrete Block - Ext Insul
Main
4 61
0 9
4
569.3 ft'
0
0 0.3
0
-3
S
Exterior
Concrete Block - Ext Insul
Main
4 32
0 11
4
362.7 ft'
0
0 0.3
0
-4
SW
Exterior
Concrete Block - Ext Insul
Main
4 2
11 11
4
33.1 ft'
0
0 0.3
0
-5
W
Exterior
Concrete Block - Ext Insul
Main
4 55
11 9
4
521.9 ft'
0
0 0.3
0
8
NW
Exterior
Concrete Block -Ext Insul
Main
4 8
7- 11
4
97.3 ft'
-0
0 0.3
0 "
7
-
Garage
Frame - Wood
Main
11 26
1 11
4
295.6 ft'
0
0.25 0.3
0
DOORS
#
Omt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
S
Wood Main
None
.39
3
8
24 ft'
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V
#
Ornt ID
Frame
Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
n 1
Metal
Double (Clear)
Yes
0.62 0.26
N
43.3 ft'
0 ft 0 in
0 ft 0 in
None
None
2
n 1
Metal
Double (Clear)
Yes
0.62 0.26
N
112.4 ft'
0 ft 0 in
0 ft 0 in
None
None
3
n 1
Metal
Double (Clear)
Yes
0.62 0.26
N
31.6 ft'
0 ft 0 in
0 ft 0 in
None
None
4
n 1
Metal
Double (Clear)
Yes
0.62 0.26
N
6.5 ft'
0 ft 0 in
0 ft 0 in
None
None
5
e 2
Metal
Double (Clear)
Yes
0.62 0.26
N
21.3 ft'
0 ft 0 in
0 ft 0 in
None
None
ggg
y r
6
e 2
Metal
Double (Clear)
Yes
0.62 0.26
N
43.3 ft'
0 ft 0 In
0 ft 0 in
None
None
[
7
a 2
Metal
Double (Clear)
Yes
0.62 0.26
N
9.0 ft'
0 ft 0 in
0 ft 0 in
None
None
- _
8
s 3
Metal
Double (Clear)
Yes
0.62 0.26
N
48.0 ft'
0 ft 0 in
0 ft 0 in
None
None
_
9
s 3
Metal
Double (Clear)
Yes
0.62 0.26
N
8.0 ft'
0 ft 0 in
0 ft 0 in
None
None
10
s 3
Metal
Double (Clear)
Yes
0.62 0.26
N
8.0 ft'
0 ft 0 In
0 ft 0 in
None
None
11
s 3
Metal
Double (Clear)
Yes
0.62 0.26
N
15.0 ft'
0 ft 0 in
0 ft 0 in
None
None
12
sw 4
Metal
Double (Clear)
Yes
0.62 0.26
N
16.0 ft'
0 ft 0 in
0 ft 0 in
None
None
13
w 5
Metal
Double (Clear)
Yes
0.62 0.26
N
21.3 ft'
0 ft 0 in
0 ft 0 in
None
None
14
w 5
Metal
Double (Clear)
Yes
0.62 0.26
N
6.5 ft'
0 ft 0 in
0 ft 0 in
None
None
15
w 5
Metal
Double (Clear)
Yes
0.62 0.26
N
12.0 ft'
0 ft 0 in
0 ft 0 in
None
None
16
nw 6
Metal
Double (Clear)
Yes
0.62 0.26
N
20.0 ft'
0 ft 0 in
0 ft 0 in
None
None
17
NW 6
Metal
Double (Clear)
Yes
0.62 0.26
N
21.4 ft'
0 ft 0 In
0 ft 0 in
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
--
1
1012.68 ft'
1012.68 ft'
64ft
8ft
1
--
i
1
I
X
1/17/201910:39 AM
EnergyGauge® USA Section R405.4.1 Compliant Software
Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000295
1851.5 101.64 191.16 .224 5
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity
Block
Ducts
1. _Electric Strip. Heat/
_None.
COPA 29AB. kBlu/hr
1_
sys#1 _
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity Air Flow SHR
Block
Ducts
1 Central Unil/
Split
SEER: 16 48 kBtu/hr 1440 cfm 0.7
1
sys91
HOT WATER SYSTEM
# System Type SubTpe
Location
EF Cap Use SetPnt Conservation
1 Electric None
Garage
0.9 50 gal 62.3 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Carl # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
ft'
DUCTS
�/ --Supply—
V # Location R-Value Area
Return --- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT ON
RLF
HVAC#
Heat Cool"
1 Attic 6 800 ft-
Attic
777 ft' Default Leakage Main (Default) (Default)
1 1
TEMPERATURES
Progremablre �Thermostar[t:'jY
• HOct
eating l J Jan l l FeDec
b Mar
VenOng l 1 Jan l 1 Feb X Mar
CAprrralling Fans: IMarrXT� r[r` rr[[ rrXr Sepr
Apr [ May [ ] Jun rl Jul 11 Aug [ ] Sep Oct
Nov
H Nov
H Dec
1/17/2019 10:39 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
fib
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s
.ft.
0 ft'
0 ft
0.3
Main
Name:
Rating Compant:
Signature:
Date:
1/17/2019 10:39 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 5
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12.Ducts; location 8 insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location Attic/Attic
3. No. of units (if multiple -family)
3.
1
u
4. Number of bedrooms
4.
3
13. Cooling system: Capacity
48.0
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
2389
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.620
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.260
14. Heating system: Capacity
29.5
c) Area
7c.
443.7
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-faclor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
' 9. Floor type, insulation level:
- a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.90
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2.
4.0
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level a) Ceiling fans
a) Under attic 11 a. 30.0 b) Cross ventilation No
b) Single assembly 11b. c) Whole house fan No
c) Knee walls/skylight walls 11C. d) Multizone cooling credit
d) Radiant barrier installed 11d. No e) Multizone heating credit
f) Programmable thermostat Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder
Address of New Home:
Date: / 1 181 I I
City/FL Zip: FORT PIERCE, FL 34951
1/17/2019 10:39:09 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 1 of 1
-�- wrightsoft' Load Short Form
Entire House
For: MW-03
9627 KNOLLWOOD LN, FORT PIERCE, FL 34951
Job:
Date: Dec 05, 2018
By:
Htg Clg Infiltration
Outside db(°F) 43 90 Method Simplified
Inside db (OF) 70 72 Construction quality Tight
Design TD (OF) 27 18 Fireplaces 0
Daily range - L
Inside humidity (%) 30 50
Moisture difference (gr/lb) 0 68
HEATING EQUIPMENT
Make
Trade
Model
AHRI ref
,'Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
100 EFF
8.6
kW
29480
Btuh
17
OF
1550
cfm
0.048
cfm/Btuh
0
in H2O
COOLING EQUIPMENT
Make Carrier
Trade 16 SEER PURON AC
Cond CA16NA048"'•A
Coil FV4CNB006
AHRI ref 4585139
Efficiency 14.0 EER,
Sensible cooling
Latent cooling
Total cooling
Actual air flow
Air flow factor
Static pressure
Load sensible heat ratio
16 SEER
32550
Btuh
13950
Btuh
46500
Btuh
1550
cfm
0.045
cfm/Btuh
0
in H2O
0.73
ROOM NAME
Area
(ft')
Htg load
(Btuh)
Clg load
(Btuh)
Htg AVF
(cfm)
Clg AVF
(cfm)
MASTER SUITE
405
5908
5157
281
232
HER WIC
86
1236
754
59
34
HIS WIC
44
47
242
2
11
GREAT ROOM
441
5194
5680
247
255
DINING
159
3030
2960
144
133
FOYER
57
1270
1019
60
46
NOOK
142
2577
2859
123
128
KIT
164
172
1677
8
75
BED 2
184
1889
2650
90
119
BED3WIC
33
1062
635
50
28
CABANA
76
2111
2385
100
107
BED 3
243
2219
2836
106
127
BATH 2
59
1034
1007
49
45
UTILITY
49
52
673
2
30
MECH
34
414
614
20
28
A 111,
7711
1/
9C7
IVIMJ I Cm GMI rI LII YV/J VV/a GVV IVY
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
ti Wii htscfC 2018-Dew710:49:12
A= g Rig htSuile® U nlversal 201212.1.05 RSU02818 page 1
) .� C:1UsersVasonlDomments\WrightsoR HVACIMW-01rup Calc=MJ8 Front Door laces: S
Entire House
2386
32594
34526
1550
1550
Other equip loads
0
0
Equip. @ 0.95 RSM
32800
Latent cooling
12935
�Tni c.
1 neoc
1 cn,
I evToc
1
I ,ccn
V If1LJ GJVV JLJJY TJI JJ IJJV IJJV
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2018-Deo-07 10:49:12
c wrightSoft' RlghtSuiteW Universal 201212.1.05 RSU02818 page 2
AM C:1UsersUasonlDowments\Wrlghtsoft HVACXMW-03.mp CaIc=MJ8 Front Door faces: S
+�- wrightsoft Project Summary
Entire House
Job:
Date: Dec 05, 2018
By:
For:
Notes:
MW-03
9627 KNOLLWOOD LN, FORT PIERCE, FL 34951
Design Information
Weather: Vero Beach, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db
43
OF
Outside db
90
OF
Inside db
70
OF
Inside db
72
OF
Design TD
27
OF
Design TD
18
OF
Daily range
L
Relative humidity
50
%
Moisture difference
68
gr/lb
Heating Summary
Sensible Cooling Equipment Load Sizing
Structure
26835
Btuh
Structure
27408
Btuh
Ducts
5759
Btuh
Ducts
7118
Btuh
Central vent (0 cfm)
0
Btuh
Central vent (0 cfm)
0
Btuh
Humidification
0
Btuh
Blower
0
Btuh
Piping
0
Btuh
Equipment load
32594
Btuh
Use manufacturer's data
n
Rate/swing multiplier
0.95
Infiltration
Equipment sensible load
32800
Btuh
Method
Simplified
Latent Cooling Equipment Load Sizing
Construction quality
Tight
Fireplaces
0
Structure
10615
Btuh
Ducts
2320
Btuh
Heating
Cooling
Central vent (0 cfm)
0
Btuh
Area (ft)
2386
2386
Equipment latent load
12935
Btuh
Volume (ft)
24178
24178
Air changes/hour
0.11
0.06
Equipment total load
45735
Btuh
Equiv. AVF (cfm)
44
24
Req. total capacity at 0.70 SHR
3.9
ton
Heating Equipment Summary
Cooling Equipment
Summary
Make
Make Carrier
Trade
Trade 16 SEER PURON AC
Model
Cond CA16NA048""A
AHRI ref
Coil FV4CNB006
AHRI ref 4585139
Efficiency
100 EFF
Efficiency 14.0 EER,
16 SEER
Heating input
8.6
kW
Sensible cooling
32550
Btuh
Heating output
29480
Btuh
Latent cooling
13950
Btuh
Temperature rise
17
OF
Total cooling
46500
Btuh
Actual air flow
1550
cfm
Actual air flow
1550
cfm
Air flow factor
0.048
cfm/Btuh
Air flow factor
0.045
cfm/Btuh
Static pressure
0
in H2O
Static pressure
0
in H2O
Space thermostat
Load sensible heat ratio
0.73
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
r wri htsoft 2018-Deo-0710:49:12
g RightSuite® Universal 201212.1.05 RSU02818 Pagel
C:\Users\Jason\Dowments\Wrightsoft 11VAC\MW-01rup Calc=MA Front Door faces: S
MASTER F COVERED
SUITE u1Na
HERS
6'0 1
0x10x7
116 CFM GREAT ROOM
k1� 10x 10 x7
11.0 128 CFM
7'0 \\`II
6z6
10x10x7lll
125 CFM
46 CFM
®
FOYER
50 CFM
4 EXHAUST
ASTER
COVERED
BATH
ENTRY
NOOK
10x 10 x7
128 CFM
7'0
7.0
127 FM
127 CFM
10x 10x7
133 CFM
UTIL
6a
CF
3CF
DINING
7'0
5'0
4.0 DRYER
EXHAUST
e
5'0
NOTE:
ALL RETURNS SHALL HAVE DIRECT DUCTING
TO RETURN AIR PLENUM BOX.
DO NOT SCALE PLANS
KIT
Bx8x6
AHU-1
lox
107
2
x10x7
19 CFM
1'0
7'0
1oxlOx7 1 127 CFM BEDROOM 3
BATH
6x6x4
45 CFM
m11
Ru a sm
• .0
2 CAR GARAGE
ON