HomeMy WebLinkAboutCONCRETE PAD - GENERATOR2 PAD THICKNESS I \ `oryi � GENERATOR I Y I ISOMETRIC VIEW PAD DIMENSIONS: CONCRETE PAD GENERATOR i GENERATOR UNIT BY o I SEPARATE SUBMITTAL 3 (SEE SCHEDULE FOR r MINIMUM WEIGHT REQUIRED) �54"LENGTH } PLAN VIEW CONCRETE MAC100 �__32" WIDTH SIDE VIEW MIN MIN AMERICAST GENERATOR CONCRETE PAD GENERATOR TABLE: (ON -GRADE APPLICATIONS ONLY) PE ANB31.. • DRIAhA&UItIOAI- FED A ' ailT2Tl] UCENS8f5W.'NDSolw SIM PJa.NAw Rn Mnm,n 30" hL 7724D-IMF 773J6tU2o Emtlt wl�.`.werlmN.¢awn meM.Ac1,4M12�1neem -- __HVHZ OR 14ON-HVHZ COUNTY RISK EXPOSURE EXP RISK EXPOSURE (EXP RISK EXPOSURE EXP I C I D II C D III, IV C D P. BEACH 150 MPH 30.44 Psf 36.94 Psf 170 MPH 39.09 Psf 47.44 Psf 180 MPH 143.93 Psf 53.19 Psf BROWARD 156 MPH 32.92 Psf 39.95 Psf 170 MPH 39.09 Psf 47.44 Psf 1180 MPH 143.83 Psf 53.19 Psf MIAMI-DADE 165 MPH 36.83 Psf 44.69 Psf 175 MPH 41.43 Psf 150.28 Psf 1186 MPH 146.80 Psf 56.80 Psf BRAND &MODEL CAPACITY WIDTH LENGTH HEIGHT WEIGHT ALLOWABLE PRESSURE COMMENTS Generac 005871 & 005883 SO KW 25.00" 48.00" 29.00" 387lbs 41.43 Psf EXP C175 MPH &D 156 MPH Generac 005872 & 005894 14 KW 25.00" 48.00" 29.00" 439 lbs 47.44 Psf EXP C 186 MPH &D 156 MPH Generac 6459,6461, 6462 16 KW 25.00" 48.00" 29.00" 513 lbs 47.44 Psf Generac006721 16 KW 25.00" 48.00" 29.00" 448 lbs 47.44 Psf Generac 005873 & 005885 17 KW 25.00" 48.00" 29.00" 4551bs 47.44 Psf Generac 005874 & 005886 17 KW 25.00" 48.00" 29.00" 4211bs 47.44 Psf Generac 005875 & 005887 20 KW 25.00" 48.00" 29.00" 451 lbs 47.44 Psf Generac 006729 & 006730 20 KW 25.00" 48.00" 29.00" 516 lbs 47.44 Psf Generac 006551 & 006552 22 KW 25.00" 48.00" 29.00" 526 lbs 47.44Psf Kohler 14RE5&20RES 14-20 KW 26.00" 48.00" 29.00" 500 lbs 47.44 Psf GE 40323GE & 40324GE 13 KW 35.00" 39.40" 39.00" 5401bs 39.09 Psf UP C 170 MPH &D 156 MPH GE 04038215M 15 KW 33.00" 48.00" 30.50" 484lbs 43.83 Psf IXP C180 MPH &D 156 MPH GE04037817KW GE 40330GE & 40331GE 17 KW 20 KW 33.00" 33.00" 48.00" 48,00" 30.50" 30.50" 484 lbs 600 lbs 43.83 Psf 43.93 Psf Briggs& Stratton 040243-0 30 KW 31.00" 32.00" 34.00" 430 lbs 43.83 Psf Briggs & Stratton 040302-2 12 KW 33.75 " 50.00" 31.60 " 507 lbs 41.43 Psf EXP C 175 MPH & D 156 MPH Briggs & Stratton M0303-1 15 KW 33.75" 49.00" 31.60" 56216s 43.83 PSI EXP, C 180 MPH & D 156 MPH Briggs & Stratton 040304-1 18 KW 33.75" 49.00" 31.60 " 568Ibs 94.00 Psf Briggs & Stratton U0305-1 20 KW 33.75 " 49.00" 31.60 " 570 lbs 44.00 Psf Generac 7035, 7036, 7037 16 KW 25.00" 48.00" 29.00" 406 lbs 47.44 Psf EXP C 186 MPH & D 156 MPH Generac 007038 & 007039 20 KW 25.00" 48.00" 29.00 " 4481bs 47.44 Psf Generac 007042&7043 22 KW 25.00" 48.00" 29.00" 466 lbs 47.44 Psf GENERATOR MOUNTING CONFIGURATION: GENERATOR ATTACHMENT BASE OR SIMPSON A24 ANGLE BRACE W/ (4) N10 SS 316 SELF -DRILLING SCREWS TO GENERATOR GENERATOR (SEE CONCRETE PAD W SCHEDULE FOR DIMENSIONS & WEIGHT = REQUIRED) 4" 1 1 n I n l i54" LENGTH FRONT VIEW GENERATOR ANCHOR TO PAD SCHEDULE: SUBSTRATE DESCRIPTION CONCRETE: (2)-3/8"0 TITEN HD (6000 PSI OR EQUIVALENT, MIN.) 2-3/4' FULL EMBED TO CONCRETE, 3' MIN EDGE DISTANCE, 6- MIN. SPACING TO ANY ADJACENT ANCHOR. NOTES: 1. ANCHOR QUANTITY PER LONG SIDE 2. EMBEDMENT AND EDGE DISTANCE EXCLUDES FINISHES, IF APPLICABLE. 3. ENSURE MINIMUM EDGE DISTANCE AS NOTED IN ANCHOR SCHEDULE. 4. ENSURE MINIMUM SPACING TO ANY ADIACENT ANCHORS. S. FOLLOW MANUFACTURER'S INSTALLATION INSTRUCTIONS TO INSTALL ANCHORS. GENERATOR ATTACHMENT BASE, VARIES WITH MODEL SEE GENERATOR SPECS % SIMPSON TITEN HD, - SEE ANCHOR SCHEDULE 2'x3'x''/ GALV. STEEL WASHER RUBBER VIBRATION PAD �ii-- (SEE GENERATOR SPECS) 3'e THICK GALVANIZED \ WASHER& RUBBER VIBRATION PAD Z CONCRETE PAD - 6,000 PSI LIGHTWEIGHT CONCRETE PAD X CONCRETE MIX I 6,000 PSI LIGHTWEIGHT \ MASTERFIBER MAC 100 CONCRETE MIX & ROAD MESH NOTES: FOAM CORE 1. Y DISTANCE DEPEND ON GENERATOR BASE LENGTH, NO LESS THAN 2'. 2. X DISTANCE 3' FROM UNIT EDGE TO CLIP. 3. Z DISTANCE DEPEND ON GENERATOR BASE WIDTH, NO LESS THAN ANCHOR REQUIREMENTS I I I I i I I 1. i WIND DESIGN REQUIREMENTS: (BASED ON ASCE 7-10 & FLORIDA BUILDING CODE SIXTH EDITION (2017)) AT -GRADE SIGN METHOD ULTIMATE DESIGN WIND SPEED Vult - 166 mph NOMINAL DESIGN WIND SPEED Vase = 144 mph RISK CATEGORY = III INTERNAL PRESSURE COEF = N/A EXPOSURE CATEGORY = D WIND DIRECTIONALITY FACTOR KD= 0.85 ENCLOSURE CATEGORY = N/A HEIGHT H = AT GROUND GUST EFFECT FACTOR = 0.85 PRESSURE AT HEIGHT H qh = 77.56 Ib/ft2 FORCE COEFFICIENT CT = 1.44 WIND PRESSURE: P = qh G Of- 56.80 Ib/R2 (ASO) GENERAL NOTES 1. THIS SYSTEM HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE SIXTH EDITION (2017). 2. REQUIRED WIND LOAD DESIGN PRESSURES CALCULATED FOR USE WITH THIS SYSTEM SHALL BE DETERMINED UNDER SEPARATE CERTIFICATION ON A IOB-SPECIFIC BASIS IN ACCORDANCE WITH THE GOVERNING CODE. SITE -SPECIFIC LOAD REQUIREMENTS AS DETERMINED IN ACCORDANCE WITH THE APPLICABLE BUILDING CODE SHALL BE LESS THAN OR EQUAL TO THE DESIGN PRESSURE'ASD' CAPACITY VALUES LISTED HEREIN FOR ANY ASSEMBLY AS SHOWN. 3. DIMENSIONS AND WEIGHT OF UNITS SHALL CONFORM TO SPECIFICATIONS STATED HEREIN. 4. UNITS MUST BE CENTERED ON PAD WITH OPPOSITE SIDES HAVING EQUAL CLEARANCE. A MINIMUM DISTANCE FROM UNITTO PAD EDGE IS SPECIFIED. S. CALCULATIONS MADE USING LIGHTWEIGHT CONCRETE 125 PCF 6. THE AREA UNDER CONCERETE SLAB ON GROUND SHALL HAVE ALL VEGETATION, STUMPS, ROOTS, AND FOREIGN MATERIALS REMOVED PRIOR TO INSTALLATION ON COMPACTED SOIL AS VERIFIED BY OTHERS. 7. RESISTANCE TO SLIDING OF THE PAD ON THE GROUND IS NOT PART OF THIS DOCUMENT AS SOIL CHARACTERISTICS AND PAD PLACEMENT VARIES. S. ELECTRICAL GROUND, WHEN REQUIRED, TO BE DESIGNED & INSTALLED BY OTHERS. AR ALL MECHANICAL SPECIFICATIONS (CLESPACE, TONNAGE, ETC.) SHALL BE AS PER MANUFACTURER RECOMMENDATIONS AND ARE THE EXPRESS RESPONSIBILITY OFTHE CONTRACTOR. 9. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR. et. al. INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, SYSTEM ERECTION, CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES &FROM DEVIATIONS OF THIS PLAN. 10. WATER -TIGHTNESS OF EXISTING FINISHES SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING CONTRACTOR. CONTRACTOR SHALL ENSURE THAT ANY REMOVED OR ALTERED WATERPROOFING MEMBRANE IS RESTORED AFTER FABRICATION AND INSTALLATION OF STRUCTURE PROPOSED HEREIN. THIS ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY WATERPROOFING OR LEAKAGE ISSUES WHICH MAY OCCUR AS WATER -TIGHTNESS SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING CONTRACTOR. 11. THE ROLE OF THIS ENGINEER FOR THIS PROJECT IS THAT OF SPECIALTY ENGINEER AND NOT THE ENGINEER OF RECORD. CONSEQUENTLY, THE ARCHITECT/ENGINEER OF RECORD SHALL BE RESPONSIBLE FOR THE INTEGRITY OF ALL SUPPORTING SURFACES TO THIS DESIGN WHICH SHALL BE COORDINATED BY THE PERMITTING CONTRACTOR. 12. THIS DOCUMENT IS GENERIC AND DOES NOT PERTAIN TO ANY SPECIFIC PROJECT SITE. INFORMATION CONTAINED HEREIN IS BASED ON CONTRACTOR -SUPPLIED DATA AND MEASUREMENTS. ENGINEERING EXPRESS SHALL NOT BE HELD RESPONSIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS OR INACCURATE DATA OR MEASUREMENTS. DIMENSIONS ARE SHOWN TO ILLUSTRATE DESIGN FORCES AND OTHER DESIGN CRITERIA. THEY MAY VARY SLIGHTLY, BUT MUST REMAIN WITHIN THE LIMITATIONS SPECIFIED HEREIN. WORK SHALL BE FIELD VERIFIED BY OTHERS PRIOR TO CONSTRUCTION. ENGINEERING EXPRESS SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY TC REEVALUATE OUR WORK UPON DISCOVERY OF ANY INACCURATE INFORMATION PRIOR TO MODIFICATION OF EXISTING FIELD CONDMONS AND FABRICATION AND INSTALLATION OF MATERIALS. ALTERATIONS OR ADDITIONS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE OUR CERTIFICATION. 13. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED. TANK L B NNARDO, P.E. ES OD46 03/� L 018 )nomun...'A ..6X4WG_ ORDON M. B I IT 0, P.E. 1328 OTICE:IP SHEET II MS DT CONE N NORIGINAL mNA RE NGINEER SEAL 'THERE IS A DIGITAL IGNATURE ON SHEETS ALL IEEE t5 PAAT DIGITALLY IGNED FILE, SHALL LL REMAIN W IGITAL FORMAT, & PRINTED RENOOFTHIE DOWMEEREDSINT NE NOT CONSIDERED SIGNl1 NO SEALED. LFTHERE IS NO [GEE IGITAL SIGNATURE ON SHEET 1 R THIS SHEET DOES NOT ]MAIN AN ENGINEER'S u ba ZHa o �- �LLLLLLLLr>I_M 44mxg O Rv WLW. N OzaNw €ZryryIIIU- yVI. �Q W gwiD� O co Ez rcN C19ww� WW g,LU Z �w l0 In CC U.,> w 0,on w O S Z K L9 FO Q LL LLr Q N N VI T _ rk m lrl K U.i cd w w 16 d co N O uj E F- n o Z V M n Q z �S,mD."3W0 C BN w `rb M t (UCiay 1 17-3961.1 1 l