HomeMy WebLinkAboutEVALUATION REPORTa. CREEK TECHNICAL SERVICES, LLC EVALUATION REPORT Manufacturer: Manufacturing Plants: Quality Assurance: SCOPE BORAL ROOFING LLC 7575 Irvine Center Drive Irvine, CA92618 (800)669-8453 www.boralamerira.com Lake Wales, FL Okeechobee, FL Certificate of Authorization No. 29824 17520 Edinburgh Dr Tampa, FL 33647 (813)480-3421 FLORIDA BUILDING CODE 6' EDITION PRI Construction Materials Technologies (QUA9110) Issued October 15, 2018 SCANIVgo BY St, Luce County Category: Roofing Subcategory: Roofing Tiles Code Sections: 1507.3.5, 1507.3.7, 1523.6.5, 1523.6.5.2, 1523.6.5.2.2, 1523.6.5.2.3 Properties: Physical Properties, Attachment Requirements, Wind Driven Rain, Static Uplift Resistance REFERENCES Entity Report No. Standard Year American Test Lab of South Florida Inc (TST3782) RT0130.01-14 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc (TST3782) RT0426.01-14 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc (TST3782) RT0615.02-11 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Flodda Inc (TST3782) RT0615.03-11 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc (TST3782) RT0615.04-11 TAS 112 1995 ASTM C 1492 2003(2009) Amedcan Test Lab of South Flodda Inc (TST3782) RT0617.02-16 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc (TST3782) RT0617.03-16 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc (TST3782) RT0617.04-16 TAS 112 1995 ASTM C 1492 2003(2009) Amedcan Test Lab of South Florida Inc (TST3782) RT0623.04-14 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc (TST3782) RT0624.04-14 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc (TST3782) RT0624.05-14 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc (TST3782) RT1210.02-15 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc (TST3782) RT1210.03-15 TAS 112 1995 ASTM C 1492 2003(2009) Miami -Dade BCCO (CER1592) 14-0408.06 FBC (HVHZ) 2017 Miami -Dade BCCO (CER1592) 14-0416.12 FBC (HVHZ) 2017 Miami -Dade BCCO (CER1592) 15-0721.04 FBC (HVHZ) 2017 Miami -Dade BCCO (CER1592) 16-0112.07 FBC (HVHZ) 2017 Miami -Dade BCCO (CER1592) 16-0112.08 FBC (HVHZ) 2017 Miami -Dade BCCO (CER1592) 18-0509.15 FBC (HVHZ) 2017 Miami -Dade BCCO (CER1592) 18-0509.16 FBC (HVHZ) 2017 Miami -Dade BCCO (CER1592) 18-0509.17 FBC (HVHZ) 2017 Tile Roof Institute Membership Confirmation TAS 100 1995 TAS 101 1995 TAS 102 & 102(A) 1995 BOR18003 FL28328 Page 1 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ®CREEK TECHNICAL SERVICES, LLC PRODUCT DESCRIPTION B�C1iC(�'(OiCeGCY�IS� BORAL ROOFING LLC Concrete Roof Tiles Profile/Description: ASTM C 1492, TAS 112 Type 3a, flat profile, interlocking, class III concrete roof the Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications Dimensions: 16" x 10" V Figure 1. Bermuda BOR18003 FL28328 Page 2 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ®CREEK TECHNICAL SERVICES, LLC Plantation (Okeechobee) BORAL ROOFING LLC Concrete Roof Tiles Profile/Description: ASTM C 1492, TAS 112 Type 3a, flat profile, interlocking, class III concrete roof tile Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications Dimensions: 16-1/2' x 13' Figure 2. Plantation Saxony 900 Slate, Shake and Split Shake (Lake Wales) Profile/Description: ASTM C 1492, TAS 112 Type 3a, flat profile, interlocking, class III concrete roof tile Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications Dimensions: 17" x 13" x 1-5/32' (Slate) or 1-9/32' (Shake and Split Shake) NAM HOLES BOR18003 DNDERLOCK Figure 3. Saxony 900 Slate 5I32'(Slate) COVERLOCK I nis evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall not CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC NAM ROLES NAM HOLES 0 Miiill Figure 4. Saxony 900 Shake Figure 5. Saxony 900 Split Shake FL28328 BORAL ROOFING LLC Concrete Roof Tiles 1-9G2- (Shah) a 4 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ® CREEK aORAL ROOFING LLC Concrete Roof Tiles TECHNICAL SERVICES, LLC Estate "S" (Okeechobee) Profile/Description: ASTM C 1492, TAS 112 Type 1 b, low profile, interlocking, class III concrete roof file Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications Dimensions: 16-1/2" x 13" Nail Holes Figure 6. Estate Villa 900 (Lake Wales) Profile/Description: ASTM C 1492, TAS 112 Type 1 b, low profile, interlocking, class III concrete roof tile Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications Dimensions: 17.0" x 13" x2-1/8" V, BOR18003 �3" Figure 7. Villa 900 5 of 12 Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attdbutes that are not specifically addressed herein. ®CREEK TECHNICAL SERVICES, LLC Barcelona 900 (Lake Wales) BORAL ROOFING LLC Concrete Roof Tiles Profile/Description: ASTM C 1492, TAS 112 Type Is, high profile, interlocking, class III, 'S' shaped concrete roof tile Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications Dimensions: 17" x 13" x 3-5/8" t+ 5/8. M Figure 8. Barcelona 900 Galena Spanish "S" (Okeechobee) Profile/Description: ASTM C 1492, TAS 112 Type 2a, high profile, interlocking, class III 'S' shaped concrete roof tile Allowable Applications: For mechanically fastened (direct deck), mortar set or adhesive set applications Dimensions: 17" x 10" x 2.7" Fastener Holes 17" 10" Figure 9. Galena Spanish "S" BOR1 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ®CREEK TECHNICAL SERVICES, LLC Spanish "S" Nuevo (Lake Wales) BORAL ROOFING LLC Concrete Roof Tiles Profile/Description: ASTM C 1492, TAS 112 Type 2a, high profile, interlocking, class III 'S' shaped concrete roof tile Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications Dimensions: 17" x 9-3/4° x 2-27/32" Fastener APPLICATION METHOD Holes 4 17" 9-3/4" Figure 10. Spanish "S" Nuevo Installation ., r; ; ° •:.' Limited to slopes 3:12 or greater in the HVHZ; Outside the HVHZ, shall be in accordance Slope: with the recommendations of the FRSArrRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Fifth Edition Revised or RAS 118, RAS 119, or RAS 120, as applicable. Solid or closely fitted min. 15132-inch plywood sheathing for new and existing construction Roof Deck: at max. 24 in. span; In the HVHZ, new construction shall be min. 19/32 in. plywood at max. 24 in. span; Designed by others in accordance with FBC requirements. Undedayment: Installed in accordance with FBC requirements. In the HVHZ, the minimum underlayment shall be installed as described in RAS 118, RAS 119, or RAS 120, as applicable. BOR18003 FL28328 'Page 7 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G203. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ®CREEK TECHNICAL SERVICES, LLC BORAL ROOFING LLC Concrete Roof Tiles Data for Attachment Calculation"s`,for Dlret t to De ck'Applicatioris Nominal Weight (W) and "Aerodynamic' Restoring Moments due to Gravity Mg,(ft-1bo " Dimensions (I x w) Multlp31 a Direct Deck RoofTde , W (Ibf) I (ft) w (ft) t're ecrat r 3 12 '_ 4 12' TAT 6 Appl .12 Qngday 9.7 1.33 0.833 0.205 6.97 6.86 6.71 6.54 6.35 Plantation 11.6 1.375 1.08 0.289 7.79 7.67 7.52 7.32 7.04 Saxony 900 10.9 1.417 1.08 0.315 7.62 7.5 7.34 7.16 6.95 Estate "S" 10.0 1.375 1.08 0.289 6.74 6.64 6.50 6.33 6.14 Villa 900 10.9 1.42 1.08 0.315 7.62 7.50 7.34 7.15 6.95 Barcelona 900 115 1.417 1.08 0.301 7.00 6.90 6.76 6.60 6.42 Galena Spanish "S° 8.5 1.42 0.833 0.235 6.13 6.03 5.89 5.74 5.57 Spanish "S° Nuevo 8.95 1.417 0.8125 0.233 5.93 5.83 5.70 5.56 5.39 s' ` Data for Attachment Calculations for BattemApplicatrons Nominal Weight (W)and ` ^Aerodynamic Restoring Moments due to Gravity Ma (ft Ibf) _,Multlpl3ers Roof„Tile._ Dimensions,(Ixw) DireLt, k, e6 . _ + .aa+•; . ., A(ft, 31 W (Ibt) ^{ a I (ft)5 w (R) Batten ,:3 12 4 12 5 12 6 12 >7 12 :d Apphcatlona 9.7 1.33 0.833 0.189 6.53 6.43 6.29 6.14 5.97 Plantation 11.6 1.375 1.08 0.267 6.85 6.75 6.61 6.44 6.26 Saxony 900 10.9 1.417 1.08 0.291 - 6.61 6.48 6.31 6.13 Estate "S" 10.0 1.375 1.08 0.267 5.91 5.82 5.70 5.56 5.40 Villa 900 10.9 1.42 1.08 0.291 - 6.56 6.42 6.26 6.08 Barcelona 11.5 1.417 1.08 0.286 6.19 6.19 6.06 5.92 5.76 900 Spanish "S" Nuevo 8.95 1.417 0.8125 0.215 5.30 5.21 5.09 4.96 F4.82 FL28328 8 of 12 Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ®CREEK TECHNICAL SERVICES, LLC BORAL ROOFING LLC Concrete Roof Tiles A p s a Moment for Mechanlcally Fastened Applications `^ ttachrrtent Resistance Ex" iessed�a _ - ✓ The Fastener ��, Mr-(ft=lbf)' ' '� •Roof Tiles ' "_ ' ,° � " Dtrect Deck Direct Deck Type, CounE, H Slze . Sh49 Chp (mm 15132 (min,.19/32 Battens plyuvood,--�- - Nail 2 10d Ring N/A 30.9 38.1 17.2 Nail 1 10d Smooth N/A 7.3 9.8 4.9 or Screw Nail 2 10d Smooth N/A 14.0 18.8 7.4 or Screw Screw 1 #8 N/A N/A 30.8 30.8 18.2 N/A N/A 51.7 24.4 Plantation or `-°"� Saxony 900 Nail 1 10d Smooth Field 24.3 24.3 24.2 or Screw Nail 1 10d Smooth or Screw Eave 19.0 19.0 22.1 Nail 2 10d Smooth Field 35.5 35.5 34.8 or Screw Nail 2 10d Smooth or Screw Eave 31.9 31.9 32.2 Nail' 2 10d Ring N/A 50.3 65.5 48.3 Nail 2 10d Ring NIA 27.8 37.4 28.8 Nail 1 10d Smooth N/A 8.8 11.8 4.1 or Screw Nail 2 10d Smooth N/A 16.4 21.9 7.1 or Screw Screw 1 #8 N/A N/A 25.8 25.8 22.9 Estate Villa 900 Screw 2 #8 N/A N/A 47.1 47.1 49.1 Nail 1 10d Smooth or Screw Field 24.3 24.3 24.2 Nail 1 10d Smooth or Screw Eave 19.0 19.0 22.1 Nail 2 10d Smooth or Screw Field 35.5 35.5 34.8 Nail 2 10d Smooth or Screw Eave 31.9 31.9 32.2 Estate °S° Nail' 2 10d Ring N/A 43.0 67.5 50.9 I i Continued on following page This evaluation report is provided for Slate of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ®CREEK TECHNICAL SERVICES, LLC BORAL ROOFING LLC Concrete Roof Tiles Attachment F:esistance Expressed as aMomentfor Adhgsnre: or. Mortar Set Roof Tile Adhesive i Product Approval•' Paddy'' Count Average Paddy Weight(grams) M_ I (ft-Itif) Dow Chemical TILE BONDw NOA 16-0222.01 2 10.7 29.3 Barcelona 900, Galena Spanish S° or Spanish °S' Nuevo ICP Adhesives Polyset AH-160 NOA 17-0322.03 2 8 29.3 1 24 38.7 1 63 66.5 Premix Marbletite, Inc. TILE-TITE NOA 17-1016.07 N/A N/A 24.5 Barcelona 900 DAP Foam Inc. Touch N' Seal® Storm Bond " 2 Two -Component NOA 17-0829.12 2 8 66.0 1 30 63 1 60 82 Notes: j) aee manwacturers proauot approval Tor mstanation requirements. LABELING 1) All tiles shall bear the identifiable marking of the manufacturer's name or logo as follows: Manufactured in Lake Wales, FL Manufactured in Okeechobee, FL OR E N T E S R A 2`6q�� 11 of 12 This evaluation report is provided for Stale of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ® CREEK BORAL ROOFING LLC Concretee Roof Roof Tiles TECHNICAL SERVICES, LLC LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) Installation of the evaluated products shall comply with FBC Section 1507.3, FRSAITRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Fifth Edition Revised and the manufacturer's published application instructions. Installations in the HVHZ shall comply with RAS 118, RAS119 and RAS 120. 3) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. 4) All product listed in this shall tested quarterly in accordance with TAS 112 Appendix A. 5) Installation of the evaluated products shall be limited to projects in areas subjected to weathering indices of 50 or greater as illustrated in ASTM C 1492-03, figure 1 (see below). ?iii.:{:.: is i:; i': !• -50-- i 5 50 •'•WEATXERINGREGIONs st X. NEGLIGIBLE WEATHERING MODERATE WEATHERING ffl SEVERE WEATHERING COMPLIANCE STATEMENT The products evaluated herein by Zachary R Priest P.E. have demonstrated compliance with the Florida Building Code, 6v' Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. R. C) . .!pR� E No 74021 2018.10.15 �0: STATE OF :4U 19:51:52 c� -04'00' Zachary��``, 'fNA� Florida Registration No. 74021 Organization No. ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a.financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT BOR18003 12 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. �I I RINITY ERD EXTERIOR RESEARCH & DESIGN, U.C. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT 13 OXFORD, CT 06478 (203) 262-9245 EVALUATION REPORT ICP Adhesives and Sealants, Inc. Evaluation Report 02768.03.06-R8 12505 NW 40Street - FL6332-R8 — Coral Springs, FL 33065 (888)774-1419 SCOPE: SCANNED BY St. Lucie County Date of Issuance:08/08/2008 Revision 8:10/12/2017 This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the a Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: ICP Adhesives Polyset® AH-160 LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinityi ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words 'Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 9. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DC4ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 10/12/2017. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, LLC d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, L-C. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. NTINITYIERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Roof Tile Adhesives Compliance Statement: ICP Adhesives Polyset® AH-160, as produced by ICP Adhesives_and Sealants, Inc., has demonstrated compliance with the 6 h Edition (2017) Florida Building Code through testing in accordance with the Standards set forth herein. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Sections Pro a Standard Year 1504.2.1.1 Overturning resistance SSTD 11 1997 3. REFERENCES: Entivil Examination Reference Date ERD (TST 6049) Static Uplift —SSTD 11 P39740.02.12 02/20/2012 ERD (TST 6049) Static Uplift —SSTD 11 P39740.11.13-R1 01/02/2015 ICC-ES(EVL2396) 20121BC Compliance ESR-1709 12/01/2016 Miami -Dade (CER 1592) HVHZwmpliance 17-0322.03 04/27/2017 PRI(TST5878) Static Uplift —SSTD 11 ECM-001-02-01 09/21/2001 PRI(TST5878) Static Uplift —SSTD 11 PFI-006-02-01 05/09/2005 PRI (TST 5878) Static Uplift —SSTD 11 PFI-006-02-02 05/09/2005 PRI (TST 5878) Static Uplift —SSTD 11 PFI-007-02-01 10/11/2005 PRI (TST 5878) Static Uplift —SSTD 11 PFI-008-02-04 02/21/2006 PRI (TST 5878) Static Uplift —SSTD 11 PFI-009-02-03 02/21/2006 PRI (TST 5878) Static Uplift —SSTD 11 TGRI-001-02-03 10/30/2006 PRI (TST 5878) Static Uplift —SSTD 11 TGRI-001-02;03 10/30/2006 PRI(TSTS878) Static Uplift —SSTD 11 PFPI-010-02-01 12/07/2006 PRI (TST5878) Static Uplift —SSTD 11 PFPI-011-02-01 12/07/2006 PRI(TST5878) Static Uplift —SSTD 11 PFPI-012-02-01 12/07/2006 PRI (TST 5878) Static Uplift —SSTD 11 PFPI-013-02-01 12/07/2006 PRI (TST 5878) Static Uplift —SSTD 11 PFPI-014-02-01 12/07/2006 PRI (TST 5878) Static Uplift —SSTD 11 ECM-003-02-01 06/13/2008 PRI (TST 5878) Static Uplift —SSTD 11 ECM-004-02-01 06/13/2008 PRI (TST 5878) Static Uplift —SSTD 11 ECM-005-02-01 06/13/2008 PRI(TST5878) Static Uplift —SSTD 11 ECM-006-02-01 06/13/2008 PRI (TST 5878) Static Uplift —SSTD 11 ECM-007-02-01 06/13/2008 PRI (TST 5878) Static Uplift —SSTD 11 ECM-008-02-01 06/13/2008 UL LLC (QUA 9625) Quality Assurance Service Confirmation Exp. 06/05/2018 4. PRODUCT DESCRIPTION: 4.1 ICP Adhesives Polyset® AH-160 is a two -component expanding polyurethane roof tile adhesive that is mixed and dispensed from a dispensing system provided by ICP Adhesives and Sealants, Inc. The components are available in refillable tanks or disposable cylinders (ICP Adhesives PrOPack® 30 & 100). S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. Exterior Research and Design, LLC. Evaluation Report 02768.03.06-R8 rertifimte ofAuthorkadon v9503 6'x EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-R8 ICP Adhesives Polyset• AH-360; (898) 774-1419 Revision 8: 10/12/2017 Page 2 of 9 \l I KINITY J ERD 5.3 Fire classification is not'part of this evaluation. Refer to a current Roofing Materials Directory for fire ratings of this product and FBC 1505.2. 5.4 ICP Adhesives Polyset® AH-160 can be used with flat, low and high profile tiles or any rigid, discontinuous roof assembly having a current Florida Statewide Product Approval or approved on a local -level by the Authority Having Jurisdiction. 5.5 Minimumunderlayment shall be per FRSA/TRI April 2012-(04-12)- or having a currentFloridaStatewide Product Approval or approved on a local -level by the Authority Having Jurisdiction for use with ICP Adhesives Polyset® AH-160. 5.6 Field tiles, meeting the limitations of FBC 1609.5.3, using ICP Adhesives Polyset® AH-160 are limited to projects having an Aerodynamic Uplift Moment (Ma), determined in accordance with FBC 1609.5.3 or Tables 2A and 213 of FRSA/TRI April 2012 (04-12), not greater than the following Allowable Overturning Moment values. Refer to Section SO and ICP Adhesives and Sealants, Inc. published installation instructions for Adhesive Paddy Placement details. ' TABLEis FIELDTiLESINICPADNEsivEsPoLysuOAH-160 ' ALLOwABLEOVERTURNING -MOMENT PERFORMANCE'. DATA.. 2 T01 MARGIN OFS4FElY"U OYAPPUEDFOa INDEDENDENT(9NGIEORCON NUOUSPADDY) MCOWFur 4 r01 MARGINOFSAFENANMbYAPPUEDFOR INIEROEPENDEM(MOPADDY) PLACFMENr Tile (FBC 1609.5.3) Adhesive Paddy Placement Allowable Overturning . Type Profile Moment (ft-lbf) Independent; Single Paddy, Medium (W-inch, —30 gram) 60 Clay or Flat Independent; Single Paddy, Large (2x10-inch, —45 gram) 112 Concrete Interdependent; Two Paddy (44-inch on underlayment, 2x4-Inch at the overlap) 54 Independent; Single Paddy, Medium (2x7-inch, —30 gram) 39 Clay or Low/ Independent; Single Paddy, Large (2x10-inch,-54 gram) 67 Concrete Medium Interdependent; Two Paddy (4x4-inch on underlayment, 2x4-inch at the overlap) 58 .Clay High Independent; Single Paddy, Large (WO -inch, —45 gram) 134 Independent; Single Paddy, Medium (2x7-inch, ^30 gram) 65 Clay or Concrete High Independent; Single Paddy, Large (WO -inch, —63 gram) - 109 Interdependent; Two Paddy (44-inch on underlayment, 2x4-inch at tile overlap) 40 Clay Barrel 2x10-Inch x "35 gram for pans; 2 @ 1x1O-inch x-17 gram for cap 147 Concrete Barrel 2x10-inch x-35 gram for pans; 2 @ 1x10-inch x-17 gram for cap 107 ClayCap atop 2x Independent: Continuous Paddy P Y (^34 gram/k) 135 stringer Concrete Cap atop 2x Independent: Continuous Paddy (— 34 gram/ft) 116 stringer ClayCap atop 2x Interdependent: 105 stringer Head: One (1) #10 x 2Yf'screw; Overlap: 1 x 6 inch (-10.5 gram) Concrete Cap atop 2x Interdependent: 76 stringer Head: One (1) #10 x 2Y" screw; Overlap: l x 6 inch (^50.5 gram) 5.6.1 Data in Table 1 relates to installation over a '30/90' underlayment system, as detailed in the FRSA/TRI April 2012 (04-12). Alternate underlayment systems include those having a current Florida Statewide Product Approval and/or approved on a local -level by the Authority Having Jurisdiction specifically for use with ICP Adhesives Polyset® AH-160. 5.6.2 Tile roof systems using tile types or profiles other than those listed above acquiring acceptance for use with ICP Adhesives Polyset® AH-160 shall be tested in accordance with SSTD 11 or Testing Application Standard TAS 101. For the interdependent two -paddy method, an additional 2-to-1 margin above that specified in SSTD 11 or Testing Application Standard TAS 101 shall be applied in determining the 'allowable overturning moment'. Exterior Research and Design, I.I.C. Evaluation Report 02768.03.06-Rg Certifcote o/Authodrodun 09503 6TM EDIT10N (2017) FBC NON-HVHZ EVALUATION FL6332-R8 ICP Adhesives Polyset* AH-160; (B88) 774-1419 Revision 8: 10/12/2017 Page 3 of 9 �l TRINITY J ERD 5.7 Hip and ridge tiles using ICP Adhesives Polyset® AH-160 are limited to projects having hip/ridge design pressure requirements, determined in accordance with Table 1A of FRSA/TRI April 2012 (04-12), not greater than the following values. Refer to ICP Adhesives and Sealants, Inc. published installation instructions for Adhesive Paddy Placement details. TABLE 2:. HIP & RIDGE TILES IN ICP ADHESIVES POLysErO AH-160 ---�--- - --- - — ALLowABLE UPLIFT RESISTANCE PERFORMANCE DATA- 2 TO 1'WR61N OFSAFETYALREADYAPPLIED FOR INDEPENDENT (CONTINUOus PADDY) PUICEMENr 4 To 1 MARGIN OFSAFEMALREADYAPPNED FOR INTERDEPENDENT PLACEMENT Allowable Tile Substrate Attachment Method Design Pressure (Psf) Clay 2x PT ridge board Independent: Continuous Paddy (-34 gram/ft) 116 Concrete 2x PT ridge board Independent: Continuous Paddy (— 34 gram/ft) 107 Clay 2x PT ridge board Interdependent: Head: One (1) #SO x 2W screw; 90 Overlap:1 x 6 inch (-10.5 gram) Concrete 2x PT ridge board Interdependent: Head: One (1) #10 x 2Y." screw; 56 Overlap: I x 6 inch (-10.5 gram) Clay or Hip & Ridge Channel Metal (FL5374): Independent: Continuous Paddy (-34 gram/ft) 169 Concrete galvanized only Clay or Trim Lock- (FL5374): aluminum, Independent: Continuous Paddy (`34 gram/ft) 173 Concrete galvanized, Galvalume orstainless steel Clay or Trim Lock'" Plus (FL5374): aluminum, Independent: Continuous Paddy 1-34 gram/ft) 178 Concrete galvanized, Galvalume or stainless steel Clay Top Notch (FL8095) Independent: Continuous Paddy (" 32 gram/ft) 125 Concrete Top Notch (FL8095) Independent: Continuous Paddy (' 32 gram/ft) 146 6. INSTALLATION: 6.1 ICP Adhesives Polyset® AH-160 and the tile roof assembly shall be installed in accordance with FRSA/TRI April 2012 (04-12) and ICP Adhesives and Sealants, Inc. published installation instructions, subject to the limitations outlined in Section 5. 6.2 Hip and ridge boards or hip/ridge metal shall be installed in accordance with the FRSA/TRI April 2012 (04-12). Proprietary hip and ridge metal shall be installed in accordance with the manufacturer's Florida Product Approval. 6.3 Installation shall be performed by applicators who hold a valid Qualified Applicator Card presented by ICP Adhesives and Sealants, Inc. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Tomball, TX 9. QUALITY ASSURANCE ENTITY: UL, LLC. — QUA9625; (847) 664-3623; LeAnna.Gradecki@ul.com Exterior Research and Design, L-C. Evaluation Report 02768.03.06-RS Certifwte ofAuthoruation R9S03 (in' EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-R8 ICP Adhesives Polyseto AH-160: (898) 774-1419 Revision 8: 10/12/2017 Page 4 of 9 �J I KINITY ERD 10. PADDY PLACEMENT DETAILS (FROM ICP ADHESIVES AND SEALANTS, INC. PUBLISHED LITERATURE): 10.1 Independent, Medium Paddy: Nail through plastic cement Paddy (Beneath rile) (when required) Underlayment_ ° o l i Battensoptional °* Eave Courso o loin Fascia f2'm Eave Closure Flat/Low Profile rile Nail through plastic cement (when required) 1 Battens In. Medium ProfileTile Nail through plastic ce (when required) Paddy (Beneath Tile) Underlayment Battensoptional` EaveCourse Fascia Weephole Loin. .� 2 in. Eave closure Y'. Drip edge High Profile Tile ' Eave Closure Fascia Exterior Research and Design, U.C. Evaluation Report 02768.03.06-RS Certif,care ofAuthoriradon rf9503 61eEDITION (2017)FBC NON-HVHZ EVALUATION FL6332-R8 ICP Adhesives Polyset° AH-160, (888) 774-1419 Revision 8: 10/12/2017 Page 5 of 9 10.2 Independent, Large Paddy: Nail through plastic cement Paddy(BeneathTile) (when required) Underlayment ° I s x i 10 in. yR\\ Battens, optional ° Eave Course ° °10in. » Fascia tin Eave Oosure Flat/Low ProfileTile �I TRINITY ERD Medium Profile Tile Nall through plastic ce (when required) Paddy (Beneathiile) Underlayment , o _ 10 in.x 2in.wide Battens /optional e Course Fascia Weephole 10in tin Eave closure Drip edge High ProfileTile Exterior Research and Design, U-C Evaluation Report 02768.03.06-R8 Cerfiftcate of Authorization k9z03 6ry EDITION (2017) FBC NON-HVH2 EVALUATION FL6332-RB ICP Adhesives Polyset• AH-160; (889) 774-1419 Revision 8: 10/12/2017 Page 6 of 9 10.3 Interdependent. Two Paddy: Nail through plastic cement Paddy (between tiles) (when required) Battens optional a a Paddy(undertile) • Singh paddy. rr ,� on top of x4in. Single pad undertil , Single onunderlay - arWyment 2x4in. a o 10in. Fascia Eave Oosure Flat/Low Profile Tile Nall through plastic cement (when required) an sop x4in. �TRINITY I ERD paddyundertiie Medium ProfileTile Nall through plastic ce Single paddy undertile (when required) Paddy (between tiles) Battens optional Paddy (under tile) Single paddy o.n underlayment E'4 x4 in. Single 2x4in paddyon top of the R Eave Course Fascia weephole 10in Eave closure .�2in �E. Drip edge High Profile Tile tiles) ' Eave closure Fascla Exterior Research and Design, I.I.C. Evaluation Report 02768.03.06-R8 Certificate of Authorkatfon#9503 6'xEDITION(2017)FBC NON-HVH2 EVALUATION F1.6332-118 ICP Adhesives Polyset• AH-160; (888) 774-1419 Revision 8: 10/12/2017 Page 7 of 9 NTINITY ERA 10.4 10.5 Two Piece Barrel (Cap & Pan) Tile: t)Placemoughadheslvetoadtiev Oto7asq.fm Steep pltsh applications In mnta"with the pan tile. (when required) e)Tum eavors alias daem. Placo edaeNvo trz m. and mdt m rmm aaesmaeaeoa aa.erme ImtAlcarvtge. Emweq.ia cmmctareaon eaM .ldeat ld.d. cover Wa fentarshown) Remove top portion of the eave mum coven tile. Abut to semnd mum of Pantiles. Ensues eave end of Pan and cover Was are flush at eave [Inc Two Piece Barrel -High ProfileTile Hip and Ride (independent placement): A 1,aulofICP Fo4m t2M.160 mrybe spp&A etas«e raid tN mdace onbwh sides ofthe IsoM ebaud os gahimrd sneW!rase m provide areul aaotlJo. Exterior Research and Design, I.I.C. Evaluation Report 02768.03.06-R8 Certificate ofAuthor&ation 09503 eEDITION 120171 FBC NON-HVHZ EVALUATION FL6332-R8 ICP Adhesives Polyseto AH-160; (888) 774-1419 Revision 8: 10/12/2017 Page 8 of 9 �l TRINITY ERD 10.6 Hip and Ridge (interdependent placement): - END OF EVALUATION REPORT - Exterior Research and Design, U.C. Evaluation Report 02768.03.06-118 Certificate oJAutharirallon 09503 fir" EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-118 ICP Adhesives Polyset' AH-160; (888) 774-1419 Revision 8: 10/12/2017 Page 9 of 9 MEMO l etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY EVALUATION REPORT _ Polyglass USA, Inc. Evaluation Report P12060.02.09-1124 1111 West Newport Center Drive BY FL5259-1128 Deerfield Beach, FL 33442 St. Lucie County Date of Issuance: 02/24/2009 (954) 233-1230 Revision 24: 01/24/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 61h Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: O VE18SS1 O er Vmeat LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMOIetc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOIetc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 14. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DC4ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 01/24/2018. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMOIetc. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO I etc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMOI etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. NNEMOI etc. ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind Uplift FM 4474 2011 1504.3.1 Wind Uplift UL 1897 2012 1507.2.3 / 1507.1.1 Physical Properties ASTM D226 2009 1507.2.4 / 1507.1.1, 1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 2012 1507.11.2 Physical Properties ASTM D5164 2011 1507.11.2 Physical Properties ASTM D6222 2011 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: gaitt Examination Reference Date FM Approvals (TST 1867) Wind Uplift 3004091 01/12/2000 PRI (TST 5878) Physical Properties PRI01111 04/08/2002 PRI (TST 5878) Physical Properties PUSA-005-02-01 01/31/2002 PRI (TST 5878) Physical Properties PUSA-013-02-01 12/23/2002 PRI (TST 5878) Physical Properties PUSA-013-02-02 12/23/2002 PRI (TST 5878) Physical Properties PUSA-013-02-03 12/23/2002 PRI (TST 5878) Physical Properties PUSA-018-02-01 07/14/2003 PRI (TST 5878) Physical Properties PUSA-028-02-01 07/13/2005 PRI (TST 5878) Physical Properties PUSA-033-02-01 01/12/2006 PRI (TST 5878) Physical Properties PUSA-035-02-01 09/29/2006 PRI (TST5878) Physical Properties PUSA-055-02-02 12/10/2007 PRI (TST5878) Physical Properties PUSA-061-02-02 01/28/2008 PRI (TST 5878) Physical Properties PUSA-076-02-01 02/22/2008 FRI(TST 5878) Physical Properties PUSA-083-02-01 04/14/2008 PRI (TST 5878) Physical Properties PUSA-088-02-01 07/29/2009 MTI (TST 2508) Physical Properties 1X201-17A 04/O1/2008 MTI (TST 2508) Physical Properties RX14EBA O1/29/2009 ERD (TST 6049) Physical Properties 11752.09.99-1 02/08/2000 ERD (TST 6049) Wind Uplift 11757.08.01-1 08/13/2001 ERD (TST 6049) Wind Uplift 11776.06.02 01/16/2003 ERD (TST 6049) Physical Properties 02200.07.03 07/14/2003 ERD (TST 6049) Wind Uplift P1740.01.07 O1/04/2007 ERD (TST 6049) Physical Properties P5110.04.07-1 04/11/2007 ERD (TST 6049) Wind Uplift P9260.03.08 03/21/2008 ERD (TST 6049) Physical Properties P33450.08.09 08/13/2009 ERD (TST 6049) Wind Uplift P30540.11.09-111 11/30/2009 ERD (TST 6049) Physical Properties P11030.11.09-1 11/30/2009 ERD (TST 6049) Wind Uplift P11030.11.09-2 11/30/2009 ERD (TST 6049) Physical Properties P11030.31.09-3 11/30/2009 ERD (TST 6049) Physical Properties P33360.06.30 06/25/2010 ERD (TST 6049) Physical Properties P33370.03.11 03/02/2011 ERD (TST 6049) Physical Properties P33370.04.11 04/26/2011 ERD (TST 6049) Physical Properties P37300.10.11 10/19/2011 NEMO ETC, U.C. Evaluation Report P32060.02.09-R24 Certifitote ofAuthodzotion #32455 6' EDITION (2017) FBC NON-HVH2 EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 2 of 14 NNEMO I etc. Ent( Examination Reference Date ERD (TST 6049) Physical Properties P40390.08.12-1 08/06/2012 ERD (TST 6049) Physical Properties P40390.08.12-2 08/07/2012 ERD (TST 6049) Physical Properties C41420.09.12-3 09/11/2012 .ERD (TST 6049) Wind Uplift P39680.03.13 03/04/2013 ERD (TST 6049) Physical Properties P45370.04.13 04/26/2013 ERD (TST 6049) Wind Uplift P1738.02.07-R2 04/29/2013 ERD (TST 6049) Wind Uplift 11757.04.01-1-R1 04/30/2013 ERD (TST 6049) Wind Uplift P41630.08.13 08/06/2013 ERD (TST 6049) Wind Uplift P11751.05.03-R1 11/26/2013 ERD (TST 6049) Wind Uplift P11781.11.03-R1 11/26/2013 ERD (TST 6049) Physical Properties P45270.05.14 05/12/2014 ERD (TST 6049) Physical Properties 6020.07.14-1 09/08/2014 ERD (TST 6049) Physical Properties 6020.09.14-2 09/08/2014 ERD (TST 6049) Physical Properties 6020.09.14-3 09/08/2014 ERD (TST 6049) Physical Properties 6020.09.14-4 09/08/2014 ERD (TST 6049) Physical Properties 6020.09.14-5 09/08/2014 ERD (TST 6049) Physical Properties 6020.09.14-6 09/08/2014 ERD (TST 6049) Physical Properties P46520.10.14 10/03/2014 ERD (TST 6049) Physical Properties P43290.10.14 10/17/2014 ERD (TST 6049) Physical Properties PLYG-SC7550.03.15 03/24/2015 ERD (TST 6049) Physical Properties P40390.04.15 04/03/2015 ERD (TST 6049) Physical Properties P44360.10.14-R1 05/18/2015 ERD (TST 6049) Physical Properties PLYG-SC8080.05.15-1 05/20/2015 ERD (TST 6049) Wind Uplift PLYG-SC8905.05.16-1 05/17/2016 ERD (TST 6049) Physical Properties PLYG-SC8080.07.16 07/16/2016 ERD (TST 6049) Wind Uplift PLYG-SC12025.10.16 10/12/2016 ERD (TST 6049) Physical Properties PLYG-SC13040.12.16 12/27/2016 ERD (TST 6049) Physical Properties PLYG-SC11900.03.17 03/10/2017 ERD (TST 6049) Physical Properties PLYG-SC12115.08.17 08/08/2017 ICC-ES(EVL 2396) IBCCompliance ESR-1697 11/01/2014 Miami -Dade (CER 1592) HVHZ Compliance NOA 14-0717.08 01/22/2015 Polyglass USA Manufacturing Affidavit Products Current 02/18/2009 Polyglass USA P/L Affidavit Mule -Hide Cross Ltg 03/01/2008 Polyglass USA Materials Affidavit Polystick SA Compound 08/18/2011 UL, L-C. (QUA9625) Quality Control Service Confirmation Exp. 10/05/2018 4. PRODUCT DESCRIPTION: 4.1.1 Elastobase is a fiberglass reinforced ,rSBS modified bitumen base sheet. 4.1.2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet. 4.1.3 Polyglass G2 Base is a fiberglass -reinforced, asphaltic base sheet. 4.1.4 Polyglass APP Base is a fiberglass -reinforced, APP modified bitumen base sheet. 4:2 Self Adhering UndeTlayments 4.2.1 Polystick MTS or Polystick MTS PLUS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced with polyolefinic film surface; meets FRSA/TRI April 2012. 4.2.2 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an aggregate surface; meets ASTM D1970. 4.2.3 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012. NEMO ETC, U.C. Evaluation Report P12060.02.09-R24 Certificate ofAuthanzation n32455 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-RZS Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 3 of 14 ONEMOletc. 4.2.4 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester reinforced, with a granular surface; meets FRSA/TRI April 2012. 4.2.5 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/m2 polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012. 4.2.6 Polyflex SAP, Polyflex SAP FIR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) are polyester reinforced, APP modified bitumen cap sheets; meet FRSA/TRI April 2012. 4.2.7 Polystick Dual PrOTM is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface; meets ASTM D3970. 4.2.8 Polystick Tile PrOTI is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012. 4.2.9 Polystick MU-X is a nominal 54-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polypropylene film surface; meets AC188 and physical requirements of ASTM D1970 (See Section 5.8). 4.3.1 Elastoflex G TU is a polyester reinforced, modified bitumen tile underlayment composed of a sand -surfaced SBS modified bitumen back -side and granule -surfaced APP modified bitumen top -side. Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. 4.3.2 Elastoflex S6 G and Elastoflex S6 G FIR are polyester reinforced, SBS modified bitumen cap sheets; meet ASTM D6164. Elastoflex S6 G and Elastoflex S6 G FIR are for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. Elastoflex S6 G is for use as an alternate to Hot Asphalt applied "Cap Sheet' in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Elastoflex S6 G FIR is for use as an alternate to Hot Asphalt applied "Cap Sheet' in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. 4.3.3 Polyflex G and Polyflex G FIR are polyester reinforced, APP modified bitumen cap sheets; meet ASTM D6222. Polyflex G is for use as an alternate to Heat Applied "Cap Sheet' in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Polyflex G FIR is for use as an alternate to Heat Applied "Cap Sheet' in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems., 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMOIetc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. NEMO ETC, LLC. Evaluation Report P12060.02.09-R24 Certificate of Authorization#32455 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 4 of 14 NNEW10jetc. 5.5 Allowable Roof Covers: TABLE I: ROOF CO_VER'OPTIONs Underlayment Asphalt Shingles Nall -On Tile Foam -On Tile Metal wood Shakes & Shingles Slate Elastobase Yes Yes (Base Sheet ln2-plysystem) Yes (Base Sheet In 2-ply system) Yes Yes Yes ElastobaseP Yes Yes (Base Sheet In 2-ply system) (Base SheetInsystem) Yes Yes Yes Polyglass G2 Base No Yes (Base Sheet in 2-ply system) Yes (Base sheet In 2-ply system) No Na No Polyglass APP Base No Yes (Base Sheet in 2-ply system) Yes (Base sheet In 2-ply system) No No No Polystick MTS or MTS PLUS Yes Yes No Yes Yes Yes Polystick lR-Xe Yes No No No Yes Yes Polystick TUIs No Yes Yes (See 5.5.1) No No No Polystick TU Plus Yes Yes Yes (See 5.5.1) Yes Yes Yes Polystick TU Max No Yes Yes (See 5.5.1) Yes No No Polystick Dual Pro Yes No No Yes Yes Yes Polystick Tile Pro Yes Yes Yes (See 5.5.1) Yes Yes Yes Polystick MU-X Yes No No Yes Yes Yes Elastoflex S6G Yes Yes Yes (See 5.5.1) No Yes Yes Elastoflex56 G FR Yes Yes No No Yes Yes Elastoflex G TU Yes Yes Yes (See 5.5.1) No Yes Yes PolyflexG Yes Yes Yes (See 5.5.1) No Yes Yes PolyflexG FR Yes Yes No No Yes Yes Polyflex SAP or SAP FR Yes Yes Yes (See 5.5.1) No Yes Yes Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Yes Yes Yes (See 5.5.1) No Yes Yes 5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations. - •, , .,. _ TABLE lA: ALLOWABLE TIDiADHESIVE./,UNDERU\YMENT 1.: COMBINATIONS.' Adhesive Florida Product Underlayments • Approval DAP Foam Touch'n Seal Storm Bond Roof Tile Adhesive FL14506 Polystick TU Plus, Polystick TU Max Dow TileBondn" FL22525 Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro, ICP Adhesives Polyset® AH-160 FL6332 Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR) Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro, ICP Adhesives Polyset® RTA-1 FL6276 Elastoflex G TU, Elastoflex 56 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR) Refer to Tile Manufacturers orAdhesive Manufacturers Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, I.I.C. Evaluation Report P12060.02.09-R24 Certificate ofAuthorimtlon a32455 6TM EDITION (2017) FBC NON-HVHZ EVALUATION FL5Z59-R28 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 5 of 14 NNEMO etc. 5.6 Allowable Substrates: 5.6.1 Direct -Bond to Deck: Polystick (all variations), Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ➢ New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System" Panels (designed and installed to meet wind loads for project). Note: Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes. Elastoflex G TU, Elastoflex S6 G or Elastoflex 56 G FR in hot asphalt to: ➢ ASTM D41 primed structural concrete. Polyflex G or Polyflex G FR torch -applied to: ➢ ASTM D41 primed structural concrete. 5.6.2 Bond -to -Insulation: Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ➢ ASTM C1289, Type II, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck DuraGuard; Dens Deck Prime; or SECUROCK Gypsum -Fiber Roof Board. Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board. Polyflex G or Polyflex G FR torch -applied to: ➢ ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturers Product Approval. For installations under foam -on tile systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FBC Section 1504.3.1. 5.6.3 Bond to Mechanically Attached Base Laver: Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or Tile Pro self -adhered to: ➢ ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base. Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ ASTM D226, Type I or II felt; Elastobase; Elastobase P, Mule -Hide Nail Base or Polyglass G2 Base. Polyflex G or Polyflex G FR torch -applied to: ➢ Elastobase; Elastobase P, Mule -Hide Nail Base, Polyglass G2 Base or Polyglass APP Base. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in accordance with FBC Section 1504.3.1. NEMO ETC, U.C. Evaluation Report P12060.02.09-R24 Certificate ofAuthonzotion #32455 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R28 Polyglaw Roof Underlayments; (954) 233-1130 Revision 24: 01/24/2018 Page 6 of 14 NNEMO etc. 5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04- 12), Appendix A, Table 3A or FBC 1609 for determination of design wind loads. #1 Maximum Design Pressure = -90 osf Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: None Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. #2 Maximum Design Pressure =-97.5 DO: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1%" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c. #3 Maximum Design Pressure = -105 DO: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: WB-3000 Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1W ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c. #4 Maximum Design Pressure = -235 Dsf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) PG100 or ASTM p41 Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. #5 Maximum Design Pressure=-315psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Tile Pro, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. #6 Maximum Design Pressure=-622.5 Dsf Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #7 Maximum Design Pressure =-30.0Dsf": Deck: Min. 15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. NEMO ETC, I.I.C. Evaluation Report P32060.02.09-R24 Certiffmte of Authorization#32455 6'"EDITION (20171 FBC NON-HVH2 EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 7 of 14 NNEMOletc. #8 Maximum Design Pressure=-37.5 psf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. #9 Maximum Design Pressure =-37.5psf*: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One (1) or two (2) layers ASTM D226, Type II felt Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. #10 Maximum Design Pressure =-45 psf*: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One (1) layer ASTM D226, Type II felt Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c. at the 2-inch wide side laps and 4-inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered or Elastoflex G TU, applied in full mopping of hot asphalt. #11 Maximum Design Pressure=-45 psf*: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Two (2) layers ASTM D226, Type II felt Fasteners: 11 ga. x 1.25-inch long x 3/8-Inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 9-inch o.c. at the 2-inch wide side laps and 9-inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered or Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt. #12 Maximum Design Pressure =-45 psf-. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c. at the 2-inch wide side laps and 18-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #13 Maximum Design Pressure =-52.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #14 Maximum Design Pressure = -52.5 DO Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. NEMO ETC, LLC Evaluation Report P12060.02.09-R24 Certifimte ofAuthorizotion #32455 fir" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233-1230 Revision 24:01/24/2018 Page 8 of 14 NNEMOletc. #15 Maximum Design Pressure=-52.5 osf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt or Polyflex G, torch -applied. #16 Maximum Design Pressure =-60dsf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface fortorch-applied cap) Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #17 Maximum Design Pressure =-60Dsf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surfacefor hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: OMG #12 Standard Roofgrip with OMG Flat Bottom Metal Plates Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #18 Maximum Design Pressure = -67.5 osf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment) Fasteners: 12 ga. x 1.25-inch long x 3/84nch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch - applied. #19 Maximum Design Pressure=-75 osf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment) Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 104nch o.c. at the 4-inch wide side laps and 30-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch - applied. #20 Maximum Design Pressure=-90 osf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having J urisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c. at the 2-Inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #21 Maximum Design Pressure=-90 osf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #22 Maximum Design Pressure =-90 osf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface) Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. NEMO ETC, LLC. Evaluation Report P12060.02.09-R24 Cernifl=e of Authorimtion#32455 6'x EDITION (2017)FBC NON-HVHZ EVALUATION FL5259-RZ8 Polyglass Roof Underlayments; (954) 233-1230 Revision 24:01/24/2018 Page 9 of 14 ONEMOjetc. 5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 3A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD3, FM Loss Prevention Data Sheets-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.7 Exoosure Limitations: Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days after installation. Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-days after installation. Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Dual Pro, Tile Pro or Elastoflex G TU shall not be left exposed for longer than 180-days after installation. Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 30 days. Elastoflex S6 G or Elastoflex S6 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum exposure is 180 days. 5.8 Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226 roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as set forth in Section 4.3, Note 1 of ASTM D1970-15, should be established as to slip resistance. 5.9 Tile Slippage Limitations (FRSA/TRI April 2012 (04-12)): When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. s ,. r,t.a`>s>.r.3TABLE2„SILESUPPAGE LIMITATIONS.FOR . DIRER DEIX TILE INs7ALLAT10N5, _,y;d �L r'r ° h {r "r Underlayment Tile Profile Staging Method Maximum Slope Elastoflex G TU 1 Flat 10-tile stack 7:12 Lugged 8-tile stack (6 over 2) 6:12 Elastoflex S6 G or 56 G FR Flat or Lugged 6-tile stack (4 over 2) 4:12 Polystick MTS or MTS PLUS Flat - 6-tile stack (4 over 2) 5:12 Lugged 6-tile stack (4 over 2) 4:12 Polystick Tile Pro Flat or Lugged 6-tile stack (4 over 2) 7:12 Polystick TU Max Flat 6-tile stack (4 over 2) or 10-tile stack 7:12 Lugged 6-tile stack (4 over 2) 7:12 Lugged 10-tile stack 6:12 Polystick TU P Fiat 6-tile stack (4 over 2) 6:12 Lugged 6-tile stack (4 over 2) 4:12 Polystick TU Plus Flat or Lugged 6-tile stack (4 over 2) 7:12 Flat or Lugged 30-tile stack 6:12 Polyflex G or G FR Flat or Lugged 6-tile stack (4 over 2) 4:12 Polyflex SA P or SA P FR Flat or Lugged 6-tile stack (4 over 2) 4:12 NEMO ETC, U.C. Evaluation Report P32060.02.09-R24 Certificote of Authorization#32455 6'"EDITION (2017)FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 11 of 14 NNEIVIOletc. Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass PG500 Modred Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of the Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be installed in a water shedding manner. All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min. 28 lb roller) or small areas of the roof that are not accessible to a large roller or broom. 6.4.3 Tile Applications (not allowed forPolystick Dual Pro, IF Xe or Polystick MU-X): Reference Is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1. For adhesive -set tile applications, refer to Section 5.6.4 herein. 6.4.4 Two (2) Ply Underlayment Systems: Polystick MTS or MTS PLUS followed by Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Tile Pro, MU-X or Polyflex SAP is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired. Polystick MTS or MTS PLUS followed by Polystick TU P, TU Plus, TU Max, Tile Pro or Polyflex SAP is allowable for use under foam -on the systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired. 6.5.1 Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FIR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications: ✓ Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing' (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet' in the `Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. ✓ Elastoflex S6 G is for use as an alternate to "Mineral Surface Roll Roofing' (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet' in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. ✓ Elastoflex S6 G FIR is for use as an alternate to "Mineral Surface Roll Roofing' (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet' in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened the roof systems. 6.5.2 For hot -asphalt -applications, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR shall be fully asphalt -applied to the substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. 6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications: ✓ Polyflex G is for use as an alternate to the Heat Applied "Cap Sheet' in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems (Base Sheet Limited per5.6.3). ✓ Polyflex G FIR is for use as an alternate to the Heat Applied "Cap Sheet' in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems (Base Sheet Limited per 5.6.3). NEMO ETC, I.I.C. Evaluation Report P12060.02.09-R24 Cerriizate of Authorization ll32455 0EDI7ION(2017)FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments, (954) 233-1230 Revision 24: 01/24/2018 Page 13 of 14 NNEMOjetc. 6.6.2 Polyflex G or Polyflex G FIR shall be fully torch -applied to the substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course. Side and end laps shall be fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge. 6.7 Tile Staging: 6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2 herein, and Polyglass published requirements for tile staging. 6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be used on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or sail- boards, to prevent tile sliding and/or damage to the underlayment during the loading process. 6.7.3 Polyglass specifies the minimum cure time after installation of self -adhering membranes and before loading of roofing tiles is forty-eight (48) hours. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. S. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements. The following plants have qualified products under their respective physical properties specifications. Plant" t 4' ,, iu + ,Speclflcatlori ? P.'rotluct s Fernley, NV, Hazleton, PA & Winter Haven, FL ASTM D1970 Polystick MU-X Hazleton, PA M-D 13-0004 Elastoflex G TU Hazleton, PA & Winter Haven, FL ASTM D1970 Polystick IR-Xe ASTM D1970 & FRSA/TRI April 2012 Polystick TU Plus ASTM D1970 & FRSA/TRI April 2012 Polystick TU Max Tuscaloosa, AL ASTM D4601, Type II Polyglass G2 Base Winter Haven, FL ASTM D226 (physicals) Elastobase, Elastobase P ASTM D6509 Polyglass APP Base FRSA/TRI April 2012 Polystick MTS, Polystick MTS PLUS FRSA/TRI April 2012 Polystick TU P FRSA/TRI April 2012 Polyflex SAP, Polyflex SA P FIR ASTM D1970 Polystick Dual Pro ASTM D1970 & FRSA/TRI April 2012 Polystick Tile Pro ASTM D6164 Elastoflex S6, Elastoflex S6 G FIR ASTM D6222 Polynex G, Polyflex G FIR 9. QUALITY AssURANCE ENTITY: UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com END OF EVALUATION REPORT - NEMO ETC, LLC. Evaluation Report P12060.02.09-R24 Cenijicute ofAuthonYotion N32455 6'"EDITION (2017)FBC NON-HVHZ EVALUATION FL5259-1128 Polyglass Roof Underlayments; (954) 233.1230 Revision 24: 01/24/2018 Page 14 of 14