NOTICE OF ACCEPTANCE (NOA) www.miamidade.sov/economy
Polyglass USA Inc.
1111 W. Newport Center Drive
Deerfield Beach, FL 33442
SCOPE:
SCANNED
BY
St. Lucie County
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: yglacc P.nl ylgepiv
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No.14-0717.08 and consists of pages 1 through 8.
The submitted documentation was reviewed by Gaspar J Rodriguez.
NOA No.: 15-0410.04
Expiration Date: 09/13/21
Approval Date: 08/11/16
Page 1 of 8
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub -Category: Underlayment
Material: SBS , APP Self -Adhering Modified Bitumen
PRODUCTS DESCRIPTION:
Test
Product
Product
Dimensions
Specification
Descriution
Polystick IR-Xe
65' x 3'33/8"
ASTM D 1970
A fine granular/sand top surface self -adhering, APP
Manufacturing
Or 65' x 3'
polymer modified, fiberglass reinforced, bituminous
Location #1 & #2
60 mils thick
sheet material for use as an underlayment in sloped roof
assemblies. Designed as an ice & rain shield.
Polystick Dual Pro
61' x 3'33/s"
TAS 103 and
A rubberized asphalt self -adhering, glass-fiber/polyester
Manufacturing
60 mils thick
ASTM D 1970
reinforced waterproofing membrane. Designed as a
Location #2
metal roofing and roof tile underlayment.
Polystick Tile Pro
61' x 3'33/81'
TAS 103 and
A rubberized asphalt self -adhering, glass-fiber/polyester
Manufacturing
60 mils thick
ASTM D 1970
reinforced waterproofing membrane. Designed as a metal
Location #2
roofing and roof tile underlayment.
Polystick TU Max
65'8" x 35-3/8"
TAS 103 and A rubberized asphalt self -adhering, polyester reinforced
Manufacturing
60 mils thick
ASTM D 1970 waterproofing membrane. Designed as a a roof tile
Location #1 & #2
underlayment.
Polystick TU P
32'10" x 3'33/8"
TAS 103 and A rubberized asphalt waterproofing membrane, glass -
Manufacturing
130 mils thick
ASTM D 1970 fiber/polyester reinforced, with a granular surface
Location #2
designed for use as a tile roof underlayment.
Polystick TU Plus
65' x 3'33/8"
TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester
(Surface Printing)
80 mils thick
ASTM D 1970 reinforced waterproofing membrane. Designed as a metal
Manufacturing
roofing and roof tile underlayment.
Location #1 & #2
Polystick MTS
65'8" x 3'33/8"
TAS 103 A homogeneous, rubberized asphalt waterproofing
Manufacturing
60 mils thick
membrane, glass fiber reinforced with polyolefinic film
Location 92
on the upper surface for use as an underlayment for metal
roofing, roof rile, slate tiles and shingle underlayment.
Polystick MTS Plus
65'8" x 3'33/8"
TAS 103 A homogeneous, rubberized asphalt waterproofing
Manufacturing
60 mils thick
membrane, glass fiber reinforced with polyolefinic film
Location #2
on the upper surface for use as an underlayment for metal
roofing, roof tile, slate tiles and shingle underlayment.
Elastoflex S6 G
32'10" x 3'33/s"
TAS 103 and Polyester reinforced, SBS modified bitumen membrane
Manufacturing
ASTM D 6164 with a sanded back face and a granule top surface. For
Location #2
use in roof tile underlayment systems.
NOA No.: 15-0410.04
Expiration Date: 09/13/21
Approval Date: 08/11/16
Page 2 of 8
MANUFACTURING PLANTS:
1. Hazelton, PA
2. Winter Haven, FL
EVIDENCE SUBMITTED
Test Aeencv
Test Identifier
Test Name/Report
Date
Trinity ERD
P10870.09.08-R1
TAS 103
12/04/08
P10870.04.09
TAS 103/ASTM D4798 & G155
04/13/09
P33360.06.10
ASTM D1970
07/01/10
P33370.03.11
TAS 103
03/02/11
P33370.04.11
ASTM D 1623
04/26/11
P36900.09.11
TAS 103/ASTM D4798 & G155
09/01/11
P37300.10.11
TAS 110/ASTM D4798 & D1970
10/19/11
P40390.08.12-2
ASTM D 1623
08/07/12
P37590.07.13-1
ASTM D6164
07/02/13
P45270.05.14
TAS 103, TAS 110 & ASTM D1623
05/12/14
P46520.10.14
ASTM D1623
10/03/14
P44360.10.14
TAS 103 & TAS 110
10/07/14
P43290.10.14
ASTM D 1970 & TAS 110
10/17/14
PLYG-SC10130.06.16-3
TAS 103 & TAS 110
06/27/16
PLYG-10130.06.16-1
ASTM D1970 & TAS 110
06/27/16
PRI Asphalt Technologies
PUSA-035-02-01
TAS 103
09/29/06
PUSA-055-02-02
TAS 103
12/10/07
PUSA-089-02-01
TAS 103/ASTM D4798 & G155
07/06/09
Momentum Technologies, Inc.
JX20H7A
TAS 103/ASTM D4798 & G155
04/01/08
RX14E8A
TAS 103/ASTM D4798 & G155
11/09/09
DX23138B
TAS 103/ASTM D4798 & G155
02/18/10
DX23138A
TAS 103/ASTM D4798 & G155
02/18/10
LABELING:
1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city
and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved"
or the Miami -Dade County Product Control Seal as shown below.
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the
installation of this materials.
NOA No.: 15-0410.04
Expiration Date: 09/13/21
Approval Date: 08/11/16
Page 3 of 8
INSTALLATION PROCEDURES:
Deck Type 1: Wood, non -insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(1): Anchor sheet mechanically fastened to deck, membrane adhered
Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
base sheet only)
Membrane: Polystick ER-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick
TU P, Polystick TU Plus, Polystick MTS or Polystick MTS Plus, self -adhered.
Surfacing: See General Limitations Below.
Deck Type 1: Wood, non -insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(2): Anchor sheet mechanically fastened to deck, membrane adhered
Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
base sheet only)
Membrane: Elastoflex S6 G, hot asphalt applied
Surfacing: See General Limitations Below.
Deck Type 1: Wood, non -insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered.
Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for
base sheet only)
Ply Sheet: Polystick MTS Plus, self -adhered with minimum 3" horizontal laps and minimum 6" vertical
laps.
Membrane: Polystick TU Plus, self -adhered.
Surfacing: See General Limitations Below.
NOA No.: 15-0410.04
r9AM14=EC000TY
.., ., Expiration Date: 09/13/21
Approval Date: 08/11/16
Page 4 of 8
INSTALLATION REQUIREMENTS:
1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose deck panels, and
sweep the deck thoroughly to remove any dust and debris prior to application.
2. Place the underlayment over metall drip edge in accordance with RAS 111.
3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact.
Remove the release film as the membrane is applied. All side laps shall be a minimum of 3-%2" and end laps
shall be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of
the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building
code.
4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the
membrane from the center outward in both directions.
5. For ridge applications, center the membrane and roll from the center outward in both directions.
6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention
to lap areas.
7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance.
8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be
pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be
applied over the underlayment.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. Polystick Dual Pro, Polystick Tile Pro, Polystick TU Plus, Polystick MTS and Polystick MTS Plus may be
used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, roof file systems and quarry
slate roof assemblies.
Polystick TU P may be used in all the previous assemblies listed except metal roofing.
Polystick IR-Xe may be used in all the previous assemblies listed except metal roofing and roof tile systems.
Polystick TU Max may be used in non-structural metal roofing and roof tile systems.
Elastoflex S6 G may be used in roof tile systems only.
3. Deck requirements shall be in compliance with applicable building code.
4. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall be applied to a smooth, clean and dry surface. The deck
shall be free of irregularities.
5. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall not be adhered directly over a pre-existing roof membrane
as a recover system.
6. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporary roof for longer than the
amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product
exposure times; not to exceed the preceeding maximum time limitations.
Exposure
Limitations (Davs)
MTS
IR-Xe
Elastoflex
S6 G
TU
Plus
TU P
Tile Pro
Dual Pro
TU Max
MTS Plus
Winter Haven, FL
180
90
180
180
180
180
180
180
180
Hazelton, PA
N/A
90
N/A
180
N/A
N/A
N/A
180
N/A
NOA No.: 15-0410.04
Expiration Date: 09/13/21
Approval Date: 08/11/16
Page 5 of 8
7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile
manufacturer's Notice of Acceptance.
Polystick Tile Pro, Polystick TU Max, Polystick TU Plus or Elastoflex S6 G may be used in both adhesive
set and mechanically fastened roof tile applications.
Polystick Dual Pro is limited to mechanically fastened roof tile applications.
Polystick MTS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in
Section 9.
Polystick TU P may be used in mechanically fastened roof tile applications with the exception of mortar set tile
applications.
9. When loading roof tiles on roof tile underlayment for (direct -to -deck) tile assemblies, the maximum roof slope
shall be as follows: (See Table Below)
Tile Profile
Polystick MTS
Elastoflex
Polystick TU Plus, TU P,
Polystick
Polystick
S6 G
Tile Pro, Dual Pro
TU Max
MTS Plus
Flat Tile
Prohibited
4:12
6:12
6:12
5:12
without battens
Profiled Tile
Prohibited
4:12
6:12
6:12
4:12
without battens
The above slope limitations can be exceeded only by using battens in accordance with the Approved Tile System
Notice of Acceptance and applicable Florida Building Code requirements. When battens are required, they shall
be utilized during loading and installation of tiles.
10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of
tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure — two tiles
laid perpendicular to slope followed by a maximum four tile stack parallel to the slope, for a total of 6 tiles — for
all underlayments except Polystick MTS which shall be loaded onto battens.
Roofing Tiles
is Max. Per Stack)
ih lr naA i
i�
Fbof Deck prepare] WAN
PDLYSIICKTU Pius
NOA No.: 15-0410.04
Expiration Date: 09/13/21
Approval Date: 08/11/16
Page 6 of 8
11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU
Max, Polystick TU P, Polystick TU Plus, Polystick NITS, Polystick NITS Plus or Elastoflex S6 G may be
used with any approved roof covering Notice of Acceptance listing Polystick IR-Xe, Polystick Dual Pro,
Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick NITS, Polystick MTS
Plus or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance.
If Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick
TU Plus, Polystick NITS, Polystick NITS Plus or Elastoflex S6 G are not listed, a request may be made to the
Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Section for approval provided
that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire
testing results.
POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS.
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS.
1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are
cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable.
Please also refer to applicable Product Data Sheets of the corresponding products.
2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as per Polyglass
Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1 %" metal disk as
required in Miami -Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate
of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on
the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being
back -nailed. (Please refer to applicable local building codes prior to installation.)
3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact.
4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass
Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement,
XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement, applied in between
the application of the lap. The use of mastic between the laps does not apply to Polystick NITS.
5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile
Loading Guidelines. See General Limitations #9 and #10.
6. Battens and/or Counter -battens, as required by the tile manufacturers NOA, must be used on all projects for
pitch/slopes of TV12" or greater. It is suggested that on pitch/slopes in excess of 6 '/4"/12", precautions should be
taken, such as the use of battens to prevent tile sliding during the loading process.
7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours.
8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed
roof to wall details.
9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified
Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified
Wet/Dry Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the
Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching
membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so
that water will run parallel to or over the top of all laps of the patch.
NOA No.: 15-0410.04
Expiration Date: 09/13/21
Approval Date: 08/11/16
Page 7 of 8
10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a
minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for
rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling.
11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick
membranes commences. An approved substrate technical bulletin can be furnished upon request. It is
recommended to refer to applicable building codes prior to installation to verify acceptable substrates.
12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes can be furnished
upon request by our Technical Services Department by calling 1 (800) 894-4563.
13. Questions in regards to the application of Polyglass products should be directed to our Technical Services
Department at 1 (800) 894-4563.
14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by
the National Roofing Contractors Association (NRCA).
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS.
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS.
END OF THIS ACCEPTANCE
NOA No.: 15-0410.04
NLpM111ADECOUNMW
Expiration Date: 09/13/21
Approval Date: 08/11/16
Page 8 of 8
RECEIVED
FEB 2 0 Z019
ST. Lucie County, Permitting MIAMI-DADE COUNTY
M®'�� RODUCT CONTROL SECTION
M 11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
Entegra Roof Tile, LLC `SCA YN��
1289 NE 9`h Ave B
Okeechobee, FL. 34972 St �uC/e County
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in
Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or
material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of
such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by
Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable
building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code including
the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: KM CoaCTefe EI9t RopflTiCe�
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in
the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall
be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 14-1120.06 and consists of pages 1 through 6.
The submitted documentation was reviewed by Gaspar J Rodriguez.
NOA No. 16-0112.07
Expiration Date: 06/07/21
Approval Date: 02/25/16
Page 1 of 6
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub Category: Roofing Tiles
Material: Concrete
1. SCOPE
This approves a roofing system using Entegra Flat Concrete Roof Tile, as manufactured Entegra Roof Tile, LLC
in Okeechobee, FL as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida
Building Code for High Velocity Hurricane Zone. For use in the locations where the pressure requirements, as
determined by applicable Building Code, do not exceed the design pressure values obtain by calculations in
compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be prepared
as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by
Applicant Dimensions
Entegra Flat Tile Length = 16"
Width = 10"
Trim Pieces 1= vanes
w = vanes
varying thickness
2.1 MANUFACTURING LOCATION
1. Okeechobee, FL
2.2 EVIDENCE SUBMITTED
Test Agencv
Redland Technologies
The Center for Applied Engineering,
Inc.
The Center for Applied Engineering,
Inc.
The Center for Applied Engineering,
Inc.
The Center for Applied Engineering,
Inc.
The Center for Applied Engineering,
Inc.
The Center for Applied Engineering,
Inc.
Test
Specilications
Product
Description
TAS 112 Flat profile, interlocking, high pressure extruded
Type 3a concrete roof tile equipped with two nail holes.
Class III For mechanical, mortar or adhesive set
applications.
TAS 112 Accessory trim, concrete roof pieces for use at
hips, rakes, ridges and valley terminations.
Manufactured for each tile profile.
Test Identifier
Test Name/Report
Date
7161-03
Static Uplift Testing
Dec. 1991
Appendix III
PA 102 & PA 102(A)
94-084
Static Uplift Testing
May 1994
PA 101 (Mortar Set)
94-060A
Static Uplift Testing
March, 1994
PA 101 (Adhesive Set)
25-7094-2
Static Uplift Testing PA 102
Oct. 1994
(4" Headlap, Nails, Direct Deck, New
Construction)
25-7094-8
Static Uplift Testing PA 102
Oct. 1994
(4" Headlap, Nails, Battens)
25-7094-5
Static Uplift Testing PA 102
Oct. 1994
(4" Headlap, Nails, Direct Deck,
Recover/Reroof)
25-7183-6
Static Uplift Testing PA 102
Feb. 1995
(2 Quik-Drive Screws, Direct Deck)
NOA No. 16-0112.07
Expiration Date: 06/07/21
Approval Date: 02/25/16
Page 2 of 6
2.2 EVIDENCE SUBMITTED
Test Agenev
The Center for Applied Engineering,
Inc.
The Center for Applied Engineering,
Inc.
The Center for Applied Engineering,
Inc.
Redland Technologies
Redland Technologies
Redland Technologies
Redland Technologies
The Center for Applied Engineering,
Inc.
Atlanta Testing & Engineering, Inc.
Professional Service Industries, Inc.
Celotex Corporation Testing Service
Celotex Corporation Testing Service
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Test Identifier
25-7183-5
25-7214-1
25-7214-5
7161-03
Appendix II
Letter Dated Aug. 1,
1994
P0631-01
P0402
Project No. 307025
Test #MDC-77
RI.894
R2.894
R3.894
395-40011-1
520109-1
520111-4
520191-1
Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
Walker Engineering, Inc. Evaluation Calculations
Walker Engineering, Inc. Evaluation Calculations
Walker Engineering, Inc. Calculations
Nutting Engineers 13343.1
American Test Lab of South Florida RT1210.02-15
Test Name/Report
Static Uplift Testing
PA 102
(2 Quik-Drive Screws, Battens)
Static Uplift Testing
PA 102
(1 Quik-Drive Screw, Direct Deck)
Static Uplift Testing
PA 102
(1 Quik-Drive Screw, Battens)
Wind Tunnel Testing
PA 108 (Nail -On)
Wind Tunnel Testing
PA 108 (Nail -On)
Wind Tunnel Testing
PA 108 (Mortar Set)
Withdrawal Resistance Testing of screw
vs. smooth shank nails
Wind Driven Rain
PA 100
Physical Properties
PA 112
Physical Properties
PA 112
Static Uplift Testing
PA 101
Static Uplift Testing
PA 101
Aerodynamic Multiplier
25-7094
25-7496
25-7584
25-7804b-8
25-7804-4 & 5
25-7848-6
25-7183
Restoring Moment, Mg
Two Patty Adhesive Set System
TAS 112
TAS 112
Date
Feb. 1995
March, 1995
March, 1995
Dec. 1991
Aug. 1994
July 1994
Sept. 1993
Oct. 1994
Aug. 1994
Feb 2004
Dec. 1998
March 1999
March 2004
Feb 1996
April 1996
December
1996
March 1995
March 2004
April 1999
05/06/08
12/17/15
MIAMI•DADE COUNTY NOA No. 16-0112.07'
• •.. � Expiration Date: 06/07/21
Approval Date: 02/25/16
Page 3 of 6
3. IdMITATIONS:
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may
required, refer to applicable building code.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in
accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami -Dade Product Control
Section for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
4. INSTALLATION
4.1 Entegra `Flat' Concrete Roof Tile and its components shall be installed in strict compliance with Miami
Dade County Roofing Application Standard RAS 118, RAS 119, and RAS 120.
4.2 Data For Attachment Calculations.
Table 1: Average Weight (W) and Dimensions (I x w )
Tile Profile
Weight-W (lb f)
Length-1 (ft)
Width-w (ft)
Entegra Flat Tile
9.7
1.33
.833
Table 2: Aerodynamic Multipliers - 2. (W)
Tile
Profile
R, (ft3)
Batten Application
2 UP)
Direct Deck Application
Entegra Flat Tile
0.189
0.205
Table 3: Restoring Moments due to Gravity - Mg (ft-lbf)
Tile
Profile
3":12"
4":12"
5":12"
VAT'
Greater than
7":12"
Entegra Flat Tile
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
6.53
6.97
6.43
6.86
6.29 1
6.71
6.14
6.54
5.97
6.35
NOA No. 16-0112.07
Expiration Date: 06/07/21
Approval Date: 02/25/16
Page 4 of 6
Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
for Nail -On Systems
Tile
Profile
Fastener Type
Direct Deck
(min 15/32" plywood)
Direct Deck
(min. 19/32" plywood)
Battens
Entegra Flat
2-10d Ring Shank Nails
30.9
38.1
17.2
Tile
1-10d Smooth or Screw
Shank Nail
7.3
9.8
4.9
2-10d Smooth or Screw
Shank Nails
14.0
18.8
7.4
1 #8 Screw
30.8
30.8
18.2
..8_0rx
51.7
0115"
24.4
1-10d Smooth or Screw
Shank Nail Field Clip)
24.3
24.3
24.2
1-10d Smooth or Screw
Shank Nail Eave Clip)
19.0
19.0
22.1
2-10d Smooth or Screw
Shank Nails Field Clip)
35.5
35.5
34.8
2-10d Smooth or Screw
Shank Nails Eave Clip)
31.9
31.9
32.2
2-10d Ring Shank Nails' 50.3 65.5 48.3
1 Installation with a 4" the headlap and fasteners are located a min. of 2'/z° from head of tile.
Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf)
for Two Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment Resistance
Entegra Flat Tile
Adhesive
31.33
2 See manufactures component approval for installation requirements.
3 Flexible Products Company TileBond Average weight per patty 13.9 grams.
3W 2-Component Foam Roof siv'ey - 60Avera a weight per patty 8 grams.
Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf)
for Single Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
Resistance
Entegra Flat
31VI'° 2-Component Foam Roof Tile Adhesive AH-160
118.94
Tile
3M' 2-Component Foam Roof Tile Adhesive AH-160
40.45
4 Large paddy
placement of 45 grams of 3M' 2-Component Foam Roof Tile Adhesive AH-160
5 Medium paddy placement of 24 grams of 3M' 2-Component Foam Roof Tile Adhesive AH-160
NOA No. 16-0112.07
Expiration Date: 06/07/21
Approval Date: 02/25/16
Page 5 of 6
5. LABELING
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following
statement: "Miami -Dade County Product Control Approved".
ENTEGRA FLAT TILE LABEL (LOCATED ON UNDERSIDE OF TILE)
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or the applicable Building Code in order to properly evaluate the
installation of this system. This Notice of Acceptance on its own cannot be used to obtain a building permit.
PROFILE DRAWING
ENTEGRA "FLAT" CONCRETE ROOF TILE
109
10,
FIELD TILE
16"
TffiCK BUTT TILE
END OF THIS ACCEPTANCE
NOA No. 16-0112.07
Expiration Date: 06/07/21
Approval Date: 02/25/16
Page 6 of 6
t�04Jt�1Y
DEPARTMENT OF REGULATORY AND ECONOMIC
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
ICP Adhesives and Sealants, In_c.
125 55 NW 4416 Street
Coral Springs, FL. 33065
ouMlulA)d 'Aluno:) al"I •1S
� MIAMI-DADE COUNTY
610Z Q ti 83
RODUCT CONTROL SECTION
ICE (RER) 11805 SW 26 Street, Room 208
42^EMd Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.miamidade.gov/econontv
- - -- - --- &CANNED BY
St. Lucie County
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: I( CP-`Mdhesl_ves;Potvaet RTA 1
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA# 15-1201.04 and consists of pages I through 8.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 16-0315.03
Expiration Date: 01/03/21
Approval Date: 04/07/16
Page 1 of 8
ROOFING COMPONENT APPROVAL:
Category: Roofing
Sub Category: Roof tile adhesive
Materials: Polyurethane
SCOPE:
This approves ICP Adhesives Polyset® RTA-1 as manufactured by ICP Adhesives and Sealants, Inc. as described
below in this Notice of Acceptance. For the locations where the pressure requirements, as determined by applicable
building code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127. For use
with approved flat, low, and high profile roof tile systems using ICP Adhesives Polyset® RTA-1.
PRODUCTS MANUFACTURED BY APPLICANT:
Product Dimensions Test Product Description
Specifications
ICP Adhesives Polyset® N/A TAS 101 Single component polyurethane foam roof tile
RTA-1 adhesive.
PRODUCTS MANUFACTURED BY OTHERS:
Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment
resistance values with the use of ICP Adhesives Polyset® RTA-1 roof tile adhesive.
MANUFACTURING LOCATION:
1. Norton, OH.
PHYSICAL PROPERTIES:
Proper
Test
Density
ASTM D 1622
Compressive Strength
ASTM D 1621
Tensile Strength
ASTM D 1623
Water Absorption
ASTM D 2842
Moisture Vapor Transmission
ASTM E 96
Dimensional Stability
ASTM D 2126
Closed Cell Content
ASTM D 2856
Results
1.95 lbs./ft.3
7.8 psi
15 PSI Parallel to rise
4.6 Lbs./Ftz
1.94 Perm / Inch
+0.89% Volume Change @ 70' C., 2 Weeks
54.1 %
Note: The physical properties listed above are presented as typical average values as determined by
accepted ASTM test methods and are subject to normal manufacturing variation.
M"I•DADECOUNTY
,.... 1
NOA No.: 16-0315.03
Expiration Date: 01/03/21
Approval Date: 04/07/16
Page 2 of 8
EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Test Name/Report
Date
Southwest Research Institute
01-1208-025
ASTM E 108
06/16/98
PRI Construction Materials
FOP-009-02-10
Physical Properties
12/14/10
Technologies, Inc.
FOP-009-02-01
TAS-101
11/8/10
FOP-009-02-02
TAS-101
11/4/10
FOP-009-02-03
TAS-101
11/8/10
FOP-009-02-04
TAS-101
11/8/10
FOP-009-02-05
TAS-101
11/8/10
LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. ICP Adhesives Polyset® RTA-1 can be used with flat, low, medium and high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® RTA-1 roof tile adhesive
with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein.
F_/21— W
MS
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
NOA No.: 16-0315.03
Expiration Date: O1/03121
Approval Date: 04/07/16
Page 3 of 8
INSTALLATION:
1. ICP Adhesives Polyset® RTA-1 may be used with any roof tile assembly having a current NOA that lists
attachment resistance values with the use of ICP Adhesives Polyset® RTA-1.
2. ICP Adhesives Polyset® RTA-1 shall be applied in compliance with the Component Application section
and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with
the -use of ICP Adhesives Polyset® RTA=1 shall provide sufficient attachment resistance.tomeet.or_exceed
the resistance values determined in compliance with Roofing Application Standards RAS 127. The
adhesive attachment data is noted in the roof tile assembly NOA.
3. ICP Adhesives Polyset® RTA-1 roof tile adhesive and its components shall be installed in accordance with
Roofing Application Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and
Maintenance Booklet
4. Installation must be by a Factory Trained'Qualified Applicator' approved and licensed by ICP Adhesives
and Sealants, Inc.
5. Tiles must be adhered in freshly applied adhesive. Tile must be set within 4 minutes after ICP Adhesives
Polyset® RTA-1 has been dispensed.
6. ICP Adhesives Polyset® RTA-1 placement shall be in accordance with the'Placement Details' herein. Each
generic tile profile requires the specific placement noted herein.
Table 1: Adhesive Placement For Each Generic Tile Profile
Tile
Profile
Typical Placement
Detail
Weight per paddy (grams)
Flat, Low & High Profile
# 1
12
High Profile 2-Piece Barrel
# 2
12
LABELING:
All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the
manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami -
Dade County Product Control Seal as shown below.
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or applicable building code in order to properly evaluate the installation of this
system.
NOA No.: 16-0315.03
Expiration Date: 01/03/21
Approval Date: 04/07/16
Page 4 of 8
a
MIAMI-DADE COUNTY
.... 1
ADHESIVE PLACEMENT DETAILS
PLACEMENT DETAIL # 1
FLAT PROFILE
NOA No.: 16-0315.03
Expiration Date: 01/03/21
Approval Date: 04/07/16
Page 5 of 8
PLACEMENT DETAm # 1(CONT... )
✓�r �� -
..NO
I _.
1
I 1 ♦ wC 1 ,I1
NOA No.: 16-0315.03
Expiration Date: O1/03/21
Approval Date: 04/07/16
Page 6 of 8
PLACEMENT DETAIL # 2
yi• i on I• • • I -
culnected to Me —
r_••
1 •
�, YF• I •' .:I •:
•• 1• •' I - -•• • 1
_•• - I - ••.. 1 _ _
HIGH PROFILE
NOA No.: 16-0315.03
MIAMI DAD; couNW Expiration Date: 01/03/21
Approval Date: 04/07/16
Page 7 of 8
PLACEMENT DETAIL # 2 (CONT...)
11 Tiro (2) - 7' thong
Eme Apales side IV
ooiuse lne \\ \�\��\ \ side under pan ties.
• \0 \\ on eat Ore ch dew
ice\ y\1 mver ties.
rA
• ^^ \\�\� r ll1
\ \
\\1) Tvo(2)-Woiarg
paddes side bl We
urn pan ties
(emeY)•
Molar ease dome
2-PIECE BARREL PROFILE
END OF THIS ACCEPTANCE
NOA No.: 16-0315.03
Expiration Date: 01/03/21
Approval Date: 04/07/16
Page 8 of 8