Loading...
HomeMy WebLinkAboutAS BUILT CERTIFICATESLab Report No. 129995 -FLORIDA TEC %„Q�9 PROVIDING SOLUTIONS TO THE ROOFING INDUSTRY 1• , C.A. # 30448 qz �� arcRec Lab Certificate k 17-0703.01 Qe�gt � RVSPECTIONDATE: October 11, 2019 PERMIT No: CLIENT NAME: Petersen Dean HOMEOWNER., PROPERTYADDRE .- 2421 Atlantic Beach Blvd., Fort Pierce - - REPRFSENTATIVE. -Andres Alvarez AS BUILT CERTIFICATE SCANNED BY St. Lucie County PF Our office inspected the above referenced roof. The roof was exposed to verify proper installation. During this inspection the following components were verified: ® Metal Panel Metal Panel: Englert Series 110124-gauge steel 16" width panel fastened at 6" o.c. throughout, according to Method 1 (FL11698.6 R4, page 5) To the best of my knowledge, belief and professional opinion, the above roof installation complies with the minimum requirements as set forth by the Florida Building Code and the approved documents. This report is no to be construed as a warranty of the roof, only the representation of the actual conditions at the time of inspection. This report cannot reasonably encompass the entire roof installation and therefore, the presented information is based specifically on the areas inspected. Do not hesitate to call my office with any questions. FILE COPY 10735 SW 216" St. Unit 404 Page 1 of 1 Tel: 305-256-4550 Miami FL 33170 www.FloridaTEC.net Fax: 305-256-6833 -j"cy� -- ®7-35 U Lab Report No. 129995 GCEp FLOR' TEC PROVIDING SOLUTIONSTO THE ROOFING INDUSTRY peQa ON 90 5� `vq `e Coy C.A. # 30448 Lab Certificate # 17-0703.01 nvsPEmoNDATE. October 11, 2019 PERMITNo: CLIENT NAME: Petersen Dean HOME OWNER PRoPERTYADDRm 2421 Atlantic Beach -Blvd., -Fort -Pierce REPRFSFNTAT[vF-- Andres Alvarez AS BUILT CERTIFICATE SCANNED St. Lucie County Our office inspected the above referenced roof. The roof was exposed to verify proper installation. During this inspection the following components were verified: ® Metal Panel Metal Panel: Englert Series 110124-gauge steel 16" width panel fastened at 6" o.c. throughout, according to Method 1(FL11698.6 R4, page 5) To the best of my knowledge, belief and professional opinion, the above roof installation complies with the minimum requirements as set forth by the Florida Building Code and the approved documents. This report is no to be construed as a warranty of the roof, only the representation of the actual conditions at the time of inspection. This report cannot reasonably encompass the entire roof installation and therefore, the presented information is based specifically on the areas inspected. Do not hesitate to call my office with any questions. CONTRACTOR COPY Jorge IF o ez, P.E. Lic. No 342 1 l�f /# 10735 SW 216n' St. Unit 404 page 1 of 1 Tel: 305-256-4550 Miami FL33170 Fax:305-256-6833 www.FloridaTEC.net