Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
EVALUATION REPORT
\CBUCK a ring Sppclelty Structure] EnglnE2rinC3 CBUCK, Inc Certificate of Authorization N8054 Evaluation Report Iq n't.--a3s o "Englert® Series 11o12F Ems` Metal Roof ASSemb LUCIE COUNTY ULDN jIEWEDFORCOMPITANG r s FILE COPY Manufacturer: pATEy 1 V Englert, Inc. PLANS AND PERMIT MUST B 1200 Amboy Avenue SITE OR NO INSPECTION(S) Perth Amboy, NJ 08862 (732)826-8614 for Florida Product Approval # FL 11698.6 R4 Florida Building Code 6th Edition (2017 Method: 1- D THESE PLANS AND ALL PROPOSED WORK Category: Roofing ARE SUBJECT TO ANY CORRECTIONS Sub -Cate REQUIRED BY FIELD INSPECTORS THAT gory: Metal Roofing MAY BE NECESSARY IN ORDER TO COIti9PLY WITH ALL APPLICABLE CODES. Product: Material: Panel Thickness: Panel Width: Panel Seam: Support: "Series 1101" Roof Panel Steel 24 gauge 16" Snap -Lock Wood Deck Faalmleofdigitalwpyslgnedby James L B ckn Prepared by: James L. Buckner, P.E., SECB Florida Professional Engineer # 312 Florida Evaluation ANE ID: 1916 N E7MK-GEALED PONSIENERS ILI[YO CHMHJTS ARE THE RCSPONSIBILJiY CIFiHE Project Manager: Diana Galloway opMRACrORORRECW Report No. 17-135-S1101-54W-ER (Revises 15-126-SI301-54W-ER, rL11698.6 R4&R3) Date: 9/16/17 Contents: Evaluation Report Pages 1-8 u er, P.E. Electronically signed and sealed dowmem shall comply with the provisions of FAC Rule 61G26-23. \ �P.: 110ENSE ••. .Qp � * • No 31242 ' _-U �.(N•-. STATE OF //ONALea���: r :to 2017.10.11 13:33:36 -04'00' CBUCK, Inc, dba CBUCK Engineering Phone: (561)491-9927 - Email: cbuck@cbuckinc.net-Website:w .cbuckinc.net Business: 1374 Community Dr., Jupiter, FL 33458 - Corp/Mailing: 2637 E. Atlantic Blvd, 934069, Pompano Beach, FL 33062 52p2cldlty Structural &nginec2rinc3 Manufacturer: Englert, Inc. 1200 Amboy Avenue Perth Amboy, NJ 08862 (732)826-8614 httR://Www.en&lertinc.com/ Product Name: "Series 1101" Product Category: Roofing Product sub -Category Metal Roofing FL Jt: FL 11699.6 R4 Date: 9 / 16 / 17 Report No.:17-135-51101-54W-ER Page 2 of 8 CBUCK, Inc Certifrcote ofAuthoriro[ion #8064 Compliance Method: State Product Approval Rule 61G20-3.005 (1) (d) Product/System "Series 1101" Roof Panel Description: 24 gauge steel Nailstrip roof panel mechanically attached to Wood Deck with screws. Product Assembly as Evaluated: Refer to Page 4 of this report for product assembly components/materials & standards: 1. Roof Panel 2. Fasteners 3. Adhesive (select systems) 4. Underlayment 5. Insulation (Optional) Support: Type: Wood Deck (Design of support system is outside the scope of this evaluation.) Description: • 15/32" or greater plywood, • or Wood plank (min. specific gravity of 0.42) Slope: Minimum slope shall be: 3 :12 or greater In compliance with FBC Chapter 15 based on the type of roof covering, applicable code sections and in accordance with manufacturer's recommendations. Performance: Wind Uplift Resistance: • Design Uplift Pressure: METHOD 1: -150 PSF (Refer to'Table A" attachment details herein) METHOD 2: -165 PSF FL lt: FL 11698.6 R4 n �� � � Date: 9 16- 17 Report No.; 3 of 951101-54W-ER �(J Page 3 of 8 ISPE'cldity StrUCturdl Englnceprtnq CBUCK, lac CertificateafqurhorizoRon7J8064 Performance The product.described herein has demonstrated compliance with: Standards: • UL580-06—Testforuplift Resistance OfRoof Assemblies • UL 1997-12 — Uplift test for roof covering systems • TAS 125-03 — Standard Requirements for Metal Roofing systems Standards Equivalency: The UL 580-94 & UL 1897-98 standard version used to test the evaluated product assembly Is equivalent with the prescribed standard UL 580-06 & UL 1897-12 adopted bythe Florida Building Code 6th Edition (2017). Code Compliance: The Product(s) described herein have demonstrated compliance with the performance standards listed above as referenced in the current Florida Building Code. Evaluation Report This product evaluation is limited to compliance with the structural Scope: requirements of the Florida Building Code, as related to the scope section to Florida Product Approval Rule 61G20-3.001. Limitations and _Scope of "Limitations and Conditions of Use" for this evaluation Conditions of Use: This evaluation report for "Optional Statewide Approval" contains technical documentation, specifications and installation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is the authority to approve products under "Optional Statewide Approval". • Option for application outside "Limitations and Conditions of Use Rule 61G20-3.005(i)(e) allows engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. • Design of support system is outside the scope of this report. • Fire Classification is outside the scope of Rule 61G20-3, and is therefore not included in this evaluation. This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade & Broward Counties) Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.0005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certifications, Inc. (FBC Organization ID# QUA 1824). SPeclalty Structural Engineering FL #: FL 11698.6 R4 Date: 9/16/17 Report No.:17-135-S1101-54W-ER Page 4 of 8 CBUCK, Inc. Certli lcote ofAuthorizotlon #so64 Components/Materials Roof Panel: Englert Series 1101 (by Manufacturer): Material: Steel Thickness: 24gauge (min.) Panel Widths: 16" (max.) Coverage Rib Height: V Yield Strength: 40 ksi min. Corrosion Resistance: Per FBC Section 1507.4.3 Fastener: Type: Pancake -Head Wood Screw Size: #10 x 1" Corrosion Resistance: Per FBC Section 1506.6 and 1507.4.4 Standard: Per ANSI/ASME B18.6.1 Seam Adhesive/Sealant: Product Name: Bostik Chem-Chaulk 915 Type: One component, polyurethane adhesive Application Size: 3/8" bead Application Location: along male flange the full length of panel (Refer to Table "A" and drawing Pg 6-7) Components& Underlayment; Materials. Material and application shall be in (by Others) compliance with FBC Section 1507.1.1 and in accordance with applicable code sections and manufacturer's recommendations. Insulation (Optional): Type: Thickness: Properties: Density: Or Compressive Strength: Rigid Insulation Board 3" (max.) 2.25 pcf (lbs/ft3) min. 20 psi min. Insulation Notes: • Rigid Insulation shall meet minimum density OR compressive strength. • Insulation shall comply with FBC Section 1508. When insulation is incorporated, fastener length shall conform to penetrate thru bottom of support a minimum of 3/16". I FL #: FL 21698.6 R4 U jp@ ©n r#n Date: 9 / 16 / 17 No.:5 51101-54W-ER "` PageRepo of g ISP2cldlty Structural EnQlneerinq CBUCK, Inc Certificate ofAutborization #8064 Installation: Installation Method: (Refer to "TABLE A" below and drawings at the end of this evaluation report.) • Fastener Spacing: Refer to"TABLE A"Below (along the length of the panel) • Rib Interlock: Snap -Lock (Panel ribs shall be fully engaged to form an integral snap -lock.) • Seam Adhesive: Refer to Table "A" & Drawing Page6. (Apply along male flange the full length of the panel.) • Minimum fastener penetration thru bottom of support, 3/16". • For panel construction at the end of panels, refer to manufacturer's instructions and any site specific design. TABLE "A" METHOD 1 METHOD 2 Design Pressure: -150 PSF -165 PSF Fastener Spacing: 6" O.C. 3" o.c. Seam Adhesive: Not required 3/8" bead (Refer to pg . 6 Notes: • Allowable design pressures) for allowable stress design DASD). Install the "Series 1101" roof Panel assembly in compliance with the installation method listed in this report and applicable code sections of FBC 6th Edition (2017). The installation method described herein is in accordance with the scope of this evaluation report. Refer to manufacturers installation instructions as a supplemental guide for attachment. Referenced Data: I. TA5125 Uplift Test By Architectural Testing, Inc. (FBC Organization ID# TST 1558) Report No. 93745.01-109-18, Date: 11/16/09 Specimens #1-3 2. Quality Assurance Keystone Certifications, Inc. (FBC Organization ID# QUA 1824) Englert, Inc. Licensee #420 3. Equivalency of Test Standard Certification By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization # ANE 1916) 4. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization # ANE 1916) Spi=cleelttj Struc:turdl EnglnePrinq FL #: FL 11698.6 R4 Date: 9 / 16 / 17 Report No.: 17-13s-S1101-54W-ER Page 6 of 8 CBUCK, Inc Cert/fimteofAuthorizotionll8064 Installation Method Englert, Inc. "Series 110111(24 gauge Steel) Roof Panel attached to Wood Deck t,. Drawings 16" Panel Profile Integral Snap Lock For METHOD 2: Apply 3/8" bead Bostik Sealant entire length of panel #'lo x 1" Pancake -Head Screw Typical Assembly Profile View (Typical Fastening Pattern Across Width) —I- 3/4" —f FL q: FL 11698.6 R4 CSKUC B u 6n pri Date: 9 / 16 Report No.:17-135-S1-S1101-54W-ER Page 7 of 8 Specialty Structural Engtnt?2rinq CBUCK, Inc Cp Hficate ofAathorizatlon H8064 Installation Method Englert, Inc. "Series 1101" (24 gauge steel) Roof Panel attached to Wood Deck Fastener. jazz vv000 ueck continuous along male rib (Refer to Table "A ) Typical Roof Assembly Isometric View (Optional) Rigid Insulation Board per Page 4 of this report TABLE "A" METHOD 1 I METHOD 2 Design Pressure: -150 PSF -165 PSF Fastener Spacing: 6" ox. 3" D.C. Seam Adhesive: Not required 3/8" bead t FL M FL 11698.6 R4 Date; 9116 / 17 Report No.:17-135-S1101-S4W-ER Page 8 of 8 SPPcldihli StrUCtUrdl Engineering CBUCK Inc. Certificat MMO NtharizoNNn 118064 (Refer to pg 6-7)