NOTICE OF ACCEPTANCE INOA wwe�.miamidade.eov/economy
Polyglass USA Inc.
1111 W. Newport Center Drive
Deerfield Beach, FL 33442
t,lo_2.-
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their -jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polyglass Polystick Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No.15-0410.04 and consists of pages 1 through 8.
The submitted documentation was reviewed by Freddy Semino.
1 at
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 1 of 8
BOCC
ROOFING COMPONENT APPROVAL
Cateeory Roofing
Sub-Cate2ory: Underlayment
Material: SBS , APP Self -Adhering Modified Bitumen
PRODUCTS DESCRIPTION:
Product
Polystick IR-Xe
Manufacturing
Location #1 & #2
Test
Dimensions Specification
Product
Description
65' x 313 ;/e" ASTM D 1970 A fine granular/sand top surface self -adhering, APP
Or 65' x 3' polymer modified, fiberglass reinforced, bituminous
60 mils thick sheet material for use as an underlayment in sloped roof
assemblies. Designed as an ice & rain shield.
Polystick Dual Pro
61' x 3'3 3/8'
TAS 103 and
A rubberized asphalt self -adhering, glass-fiber/polyester
Manufacturing
60 mils thick
ASTM D 1970
reinforced waterproofing membrane. Designed as a
Location #2
metal roofing and roof file underlayment.
Polystick Tile Pro
6F x 3'3'/e'
TAS 103 and -
A rubberized asphalt self -adhering, glass-fiber/polyester
Manufacturing
60 mils thick
ASTM D 1970
reinforced waterproofing membrane. Designed as a metal
Location #2
roofing and roof tile underlayment.
Polystick TU Max
Manufacturing
Location #1 & #2
Polystick TU P
Manufacturing
Location #2
Polystick TU Plus
(Surface Printing)
Manufacturing
Location #1 & #2
fo3 ticl
�M�nu ac nn2
atio #2
Polystick MTS Plus
Manufacturing
Location #2
Elastoflex S6 G
Manufacturing
Location #2
65'8" x 33-3/8" TAS 103 and A rubberized asphalt self -adhering, polyester reinforced
60 mils thick ASTM D 1970 waterproofing membrane. Designed as a a roof tile
underlayment.
32' 10" x 33 ;/e' TAS 103 and A rubberized asphalt waterproofing membrane, glass-
130 mils thick ASTM D 1970 fiber/polyester reinforced, with a granular surface
designed for use as a tile roof underlayment.
65' x 3'3 3/a"
80 mils thick
fim is 3'3 al
6 mil hfe -
65'8" x 3'3'/s"
60 mils thick
TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester
ASTM D 1970 reinforced waterproofing membrane. Designed as a metal
roofing and roof tile underlayment.
TAS 103 A homogeneous, rubberized asphalt waterproofing
membrane, glass fiber reinforced with polyolefinic film
on the upper surface for use as an underlayment for metal
roofing, roof tile, slate tiles and shingle underlayment.
32'10" x 3'3 %" TAS 103 and Polyester reinforced, SBS modified bitumen membrane
ASTM D 6164 with a sanded back face and a granule top surface. For
use in roof tile underlayment systems.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 2 of 8
MANUFACTURING PLANTS:
1. Hazelton, PA
2. Winter Haven, FL
Test Aaencv
- Trinity I ERD - -
PRI Asphalt Technologies
Momentum Technologies, Inc.
LABELING:
EVIDENCE SUBMITTED
Test Identifier
Test Name/Reuort
P10870.09.08-R1
TAS 103
P10870.04.09
TAS 103/ASTM D4798 & G155
P33360.06.10
ASTM D1970
P33370.03.11
TAS 103
P33370.04.11
ASTM D 1623
P36900.09.11
P37300.10.11
P40390.08.12-2
P37590.07.13-1
P45270.05.14
P46520.10.14
P44360.10.14
P43290.10.14
PLYGSC 10130.06.16-3
PLYG-10130.06.16-1
PUSA-035-02-01
PUSA-055-02-02
PUSA-089-02-01
JX20H7A
RX14E8A
DX23D8B
DX23D8A
TAS 103/ASTM D4798 & G155
TAS 110/ASTM D4798 & D1970
ASTM D 1623
ASTM D6164
TAS 103, TAS 110 & ASTM D1623
ASTM D1623 _
TAS 103 & TAS 110
ASTM D 1970 & TAS 110
TAS 103 & TAS 110
ASTM D1970 & TAS 110
TAS 103
TAS 103
TAS 103/ASTM D4798 & G155
TAS 103/ASTM D4798 & G155
TAS 103/ASTM D4798 & G155
TAS 103/ASTM D4798 & G155
TAS 103/ASTM D4798 & G155
Date
12/04/08
04/13/09
07/01/10
03/02/11
04/26/11
09/01/11
10/19/11
08/07/12
07/02/13
05/12/14
10/03/14
10/07/14
10/17/14
06/27/16
06/27/16
09/29/06
12/10/07
07/06/09
04/01/08
11/09/09
02/18/10
02/18/10
1. All membranes or packaging shall bear the imprint or identifiable marling of the manufacturer's name or logo, city
and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved"
or the Miami -Dade County Product Control Seal as shown below.
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the
installation of this materials.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 3 of 8
INSTALLATION PROCEDURES:
Deck Type 1: Wood, non -insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(1): Anchor sheet mechanically fastened to deck, membrane adhered
Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518A Nails and tin caps 12" grid, 6"o.c. at a minimum 4" �d la�for
base sheet only)
Membrane: Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick
TU P, Polystick TU Plus, Polystick MTS or Polystick MTS Plus, self -adhered.
Surfacing: See General Limitations Below.
Deck Type 1: Wood, non -insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(2): Anchor sheet mechanically fastened to deck, membrane adhered
Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
base sheet only)
Membrane: Elastollex S6 G, hot asphalt applied
Surfacing: See General Limitations Below.
Deck Type 1: Wood, non -insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered.
Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518A Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for
base sheet only)
Ply Sheet: Polystick MTS Plus, self -adhered with minimum 3" horizontal laps and minimum 6"
vertical laps.
Membrane: Polystick TU Plus, self -adhered.
Surfacing: See General Limitations Below.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 4 of
INSTALLATION REQUIREMENTS:
1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose deck panels, and
sweep the deck thoroughly to re move any dust and debris prior to application.
2. Place the underlayment over metal drip edge in accordance with RAS I11.
3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact.
Remove _the release film_as the membrane is applied. All side laps shall be a_minimum_ of 3" and end laps shall
be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the
roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code.
4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the
membrane from the center outward in both directions.
5. For ridge applications, center the membrane and roll from the center outward in both directions.
6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention
to lap areas.
7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance.
8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be
pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be
applied over the underlayment.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. Polystick Dual Pro, Polystick Tile Pro, Polystick TU Plus, Polystick MTS and Polystick MTS Plus may be
used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, roof tile systems and quarry
slate roof assemblies.
Polystick TU P maybe used in all the previous assemblies listed except metal roofing.
Polystick IR-Xe may be used in all the previous assemblies listed except metal roofing and roof tile systems.
Polystick TU Max may be used in non-structural metal roofing and roof tile systems.
Elastoflex S6 G may be used in roof file systems only.
3. Deck requirements shall be in compliance with applicable building code.
4. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MIS and Polystick MTS Plus shall be applied to a smooth, clean and dry surface. The deck
shall be free of irregularities.
5. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MIS Plus shall not be adhered directly over a pre-existing roof membrane
as a recover system.
6. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporary roof for longer than the
amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product
exposure times; not to exceed the preceeding maximum time limitations.
Exposure
Limitations (Days)
MTS
IR-Xe
Elastoflex
S6 G
TU
Plus
TU P
Tile Pro
Dual Pro
TU Max
MTS Plus
Winter Haven FL
180
90
180
180
180
180
180
1 180
180
Hazeltoo PA
N/A
90
N/A
180
N/A
N/A
N/A
1 180
N/A
All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 5 of 8
8.
Rule 61G20-3 of the Florida Administrative Code.
In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile
manufacturer's Notice of Acceptance.
Polystick Tile Pro, Polystick TU Max, Polystick TU Plus or Elastoilex S6 G may be used in both adhesive
set and mechanically fastened roof rile applications.
Polystick Dual Pro is limited to mechanically fastened roof tile applications.
Polystick MTS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in
Section 9. — — — —
Polystick TU P may be used in mechanically fastened roof tile applications with the exception of mortar set tile
applications.
9. When loading roof tiles on roof tile underlayment for (direct -to -deck) tile assemblies, the maximum roof slope
shall be as follows: (See Table Below)
Tile
Polystick
Elastoflex
Polystick TU Plus,
Polystick
Polystick
System (E3)
Profile
MTS
S6 G
TU P, Tile Pro,
TU Max
MTS Plus
MTS Plus with
Dual Pro
TU Plus
Flat Tile
Prohibited
4:12
6:12
6:12
5:12
6:12
without battens
Profiled
Prohibited
4:12
6:12
6:12
4:12
6:12
Tile
without battens
The above slope limitations can be exceeded only by using battens in accordance with the Approved Tile System
Notice of Acceptance and applicable Florida Building Code requirements. When battens are required, they shall
be utilized during loading and installation of tiles.
10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of
tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure — two tiles
laid perpendicular to slope followed by a maximum four tile stack parallel to the slope, for a total of 6 tiles — for
all underlayments except Polystick MTS which shall be loaded onto battens.
tD
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 6 of 8
11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU
Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G may be
used with any approved roof covering Notice of Acceptance listing Polystick IR-Xe, Polystick Dual Pro,
Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS
Plus or Elastoflex-S6_G as a component part of an_assembly in the Notice of Acceptance.
If Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick
TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G are not listed, a request may be made to the
Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Section for approval provided
that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire
testing results.
POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS.
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS.
1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are
cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable.
Please also refer to applicable Product Data Sheets of the corresponding products.
2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as per Polyglass
Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1 V metal disk as
required in Miami -Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate
of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on
the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being
back -nailed. (Please refer to applicable local building codes prior to installation.)
3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact.
4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass
Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement,
XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement, applied in between
the application of the lap. The use of mastic between the laps does not apply to Polystick MTS.
5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile
Loading Guidelines. See General Limitations #9 and #10.
6. Battens and/or Counter -battens, as required by the tile manufacturers NOA, must be used on all projects for
pitch/slopes of 7/12" or greater. It is suggested that on pitch/slopes in excess of 6 '/<"/l2", precautions should be
taken, such as the use of battens to prevent tile sliding during the loading process.
7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours.
8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed
roof to wall details.
9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified
Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified
Wet/Dry Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the
Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching
membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so
that water will run parallel to or over the top of all laps of the patch.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 7 of 8
10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a
minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for
rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling.
11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick
membranes commences. An approved substrate technical bulletin can be furnished upon request. It is
recommended to refer to applicable building codes prior to installation to verify acceptable substrates.
12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes can be furnished
upon request by our Technical Services Department by calling 1 (800) 894-4563.
13. Questions in regards to the application of Polyglass products should be directed to our Technical Services
Department at 1 (800) 894.4563.
14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by
the National Roofing Contractors Association (NRCA).
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS.
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS.
END OF THIS ACCEPTANCE
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 8 of 8
,q
MIAMI-DADE COUNTY
HIAMF PRODUCT CONTROL SECTION
mmm 11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2 9
NOTICE OF ACCEPTANCE (NOA) rve w.mlamidade.eov/�c nomv
I Ca FILE COPY SCANNED
1 Campus Drive BY
Parsippany, NJ 0705 St. Lucie County
SCOPE: �rD5 `j
This NOA is being issued under the applicable rules and regulations governing the use of co traction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -P duct Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Ju ' 'coon (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Da County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade nty) reserve the right to have this
product or material tested for quality assurance purposes. If this product or aterial fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the HJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RE reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Conit of Section at this product or material fails to meet the
requirements of the applicable building cam. /
This product is approved as descried herein, and ys been signed to comply with the Florida Building Code
including the High Velocity Hurricah one of the Vorida Bu' ing Code. .
DESCRIPTION: VersaShi d® Fire -Resistant Roo Deck Protection and VersaShieldo SoloT Fire -Resistant
Slip Sh ei
LABELING: Each on' shall bear ermanent abel with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Con I Approved", unless otherwise noted herein.
RENEWAL of t ' OA shall be consi red after a renewal application has been filed and there has been no change
in the applicable but ' code gdtiv y affecting the performance of this product.
TERMINATION of this NOA ill occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufac a of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any her purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be taus or termination and removal of NOA.
ADVERTISEMEN . The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date ma a displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTON: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be a ilable for inspection at the job site at the request of the Building Official.
This WA renews NOA No. 14-1022.26 and consists of pages 1 through 3.
The/ubmitted documentation was reviewed by Alex Tigera.
NOA No.: 16-1216.02
Expiration Date: 02/07/22
Approval Date: 02/02/17
i
Page 1 of
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub -Category: Underlayment
Material: Fiberglass
SCOPE:
This acceptance is for VersaShield® Fire -Resistant Roof Deck Protection (a.k.a "VersaShield® Underlayment") and
VersaShield® Solo— Fire -Resistant Slip Sheet (a.k.a "VersaShield Solon""), as described in this Notice of Acceptance,
for use with approved prepared roof assemblies. Designed to comply with the Florida Building Code and the High
Velocity Hurricane Zone of the Florida Building Code.
PRODUCT DESCRIPTION:
Manufactured b
Applicant
VersaShield® Fire -
Resistant Roof Deck
Protection
Test
Dimensions Specifications
Product .
Description
42" x 100' rolls ASTM D 226 Non -Asphaltic fiberglass -based underlayment
Type II and/or fire barrier.
VersaShield® Solo— 72" x 166.7' rolls UL790 Non -Asphaltic fiberglass -based slip sheet and/or
Fire -Resistant Slip Sheet 36, x 166.7' rolls fire barrier.
MANUFACTURING LOCATION:
Conover, NC
EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Test Name/Report
Date
PRI Construction Materials
GAF-270-02-02
ASTM D 226
11/15/10
Technologies
GAF-748-02-01
ASTM D 226
12/12/16
ELK-063-02-01
TAS 100
09/27/01
Underwriters Laboratories Inc.
99NK45831
UL790
03/21/00
1 ONK11990
UL790
05/18/11
RI9254
ASTM D 226
09/13/01
08CA37926
UL790
09/23/09
08CA49140
INSTALLATION:
1. VersaShield® Fire -Resistant Roof Deck Protection or VersaShield® Solo- Fire -Resistant Slip Sheet shall be
installed in strict compliance with applicable Building Code.
2. VersaShield® Fire -Resistant Roof Deck Protection or VersaShield®SoloTM Fire -Resistant Slip Sheet shall be
installed with a minimum 4-inch head lap in a shingle layer fashion.
3. VersaShield® Fire -Resistant Roof Deck Protection shall be mechanically fastened with approved fasteners in
compliance with Florida Building Code 1518.2 when used in lieu of a code prescribed ASTM D 226 Type II
underlayment.
APPROVED
NOA No.: 16-1216.02
Expiration Date: 02/07/22
Approval Date: 02/02/17
Page 2 of 3
LIMITATIONS:
1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire
ratings of this product
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code.
_3. VersaShield®Fire-ResistantRoof DeckPlotection.shall not be left exposed as a temporary roof for longer than 30
days of application. VersaShield® Solo- Fire -Resistant Slip Sheet shall not be left exposed to the weather.
4. VersaShield® Fire -Resistant Roof Deck Protection and VersaShield® Solo- Fire -Resistant Slip Sheet are a
component used in roof assemblies. Roof assemblies are approved under specific assembly Notice of Acceptance.
5. VersaShield® Fire -Resistant Roof Deck Protection or VersaShield® Solo- Fire -Resistant Slip Sheet may be used
with any approved roof covering Notice of Acceptance listing. VersaShield® Fire -Resistant Roof Deck Protection
or VersaShield® Solo -Fire -Resistant Slip Sheet may be used as a component part of an assembly in the Notice of
Acceptance. If VersaShield® Fire -Resistant Roof Deck Protection or VersaShield® Solo- Fire -Resistant Slip Sheet
is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product
Control Department for approval provided that appropriate documentation is provided to detail compatibility of the
products, wind uplift resistance, and fire testing results.
6. VersaShield® Fire -Resistant Roof Deck Protection and VersaShield® SoloT Fire -Resistant Slip Sheet are a non-
asphaltic underlayment that may be used as a fire barrier for prepared roof assemblies. For fire classification of
specific roof assemblies using VersaShield® Fire -Resistant Roof Deck Protection or VersaShield® Solo- Fire -
Resistant Slip Sheet refer to a current Approved Roofing Materials Directory for fire ratings of this product.
7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
LABELING:
All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and
state of manufacturing facility, yellow line to identify the ASTM Standard designation or logo, and the following
statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as
shown below.
LMIAMI•DAD; COUNTY
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by Building Official or Applicable building code in order to properly evaluate the
installation of this material.
END OF THIS ACCEPTANCE