Loading...
HomeMy WebLinkAboutCERTIFICATION - DESIGN LOAD COMPLIANCERECEI"yD CC( 04Z0t� I�oo�-ayal Planning & Development -Services Department IL 314110 Building & Code Regulations Division - -'--- - — 2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 462-1553 Certification for Design Load Compliance Project Name: V\A(-C2\11n`d Project Address: 80\S U.C�'tU�1 Or\ L.Q.v �C, �'Ccy S0.in` L-UC��,FL- Permitfl: Occupancy Type: Construction Type: f i?,E INSTRUCTIONS FOR USE, • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) SCANNED o Residential Addition BY o Any accessory structure requiring a building permit St. Lucie County o Any non-residential structure. r Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the k above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 7_0 iti Code Fifth Edition with 20 Supplements using ASCE 7-10 2. Structure Designed as (check one): Enclosed _Partially Enclosed _Open 3. Risk Category: _I V/' II _III _ IV Exposure Category: _ _B ✓ C _D 4. Design Wind Velocity 00 mph _ASD _LRFD End Zane Width: ft 5. Mean Roof Height 2,\ S't ft Roof Pitch: (:12 Parapet: (V ft, 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): 1-I`tis +4•3 Zone 1: - + 9.5 Zone 2: - 4(..1 "ks.b +4o,,j.,� 1-40,2_ .}3?S Zone 3: - b .i. Zone 4: - Y3.to Zone 5: 51. 6 Garage: - 4o,5 7. Design Loads: Floor: LJO PSF Roof/Dead: 10_PSF Roof/Live: Balcony: 0A . PSF Dock: fl N PSF Deck: C1 k PSF Stairs:_ja/A_PSF Fence:11LPSF Railings: UP\ PSF 8. Were Shear Walls Considered For Structure? Yes _Not Applicable Explain Why Not 9. Is A Continuous Load Path Provided? r - ✓ Yes _Not Applicable Explain Why Not: -. 10. Design Soil Bearing Pressure: 2-000 PSF Soil Test Reports Submitted? _Yes ��DESIGN PROFESSIONAL CERTIFICATION STATEMENT: )� I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: Signature, Date, and Seal Revised 07/25/2014 �d S l-.-)m�5—tce, Print Name C rt # & Co. Cert Auth. Li lo-1 %k-r, I Company Name & Address