HomeMy WebLinkAboutFIELD TEST - COMPACTED SOILS1798 AGORA CIRCLE S:E: SUITE 5 PALM BAY, FLORIDA 32909 1845N.W.33RD STREET POMPANO BEACH, FLORIDA 33064 SCANNED BY FIELD DENSITY TESTS OF COMPACTED SOILS St. Lucie County DATE: 07/10/00 ORDERNO: 00-1455 PERMIT NOV 50637 ? CLIENT: HARRY BLUE PLASTERING ADDRESS: 1748 S.W. BILTMORE STREET, PORT ST.LJCIE. FLORIDA 34983 PROJECT: PROPOSED RESIDENCE ADDRESS: 984 COKER ROAD FORT PIERCE FLORIDA MATERIAL DESCRIPTION: BROWN SILICA SAND FIELD DENSITY METHOD A.S.T.M D-2922 DRY DENSITY P.C.F. IN THE FIELD 107.0 107.6 106.4 • MOISTURE 6.3 7.4 7.7 % COMPACTION IN THE FIELD 99.1 99.7 98.6 • COMPACTION REQ. BY SPECS 95% DEPTH IN INCHES 12 PROCTOR T-180 A.A.S.H.T.O. METHOD LOCATION: NW CORNER LOCATION: SE CORNER LOCATION: SW CORNER _ PROCTOR T-180 A.A.S.H.T.O. % Moisture Dry Density 9.3 104.5 11.8 107.4 14.7 104.1 112 110 108 106 104 Proctor Value . 108.0 pcf Optimum Moisture 12.6 % %Passing 3/4" Sieve 100 % Laboratory Number 1045 8 10 12 14 16 ALL TEST RESULTS COMPLY WITH SPECIFICATIONS UNLESS OTHERWISE NOTED WITH AN ASTERICK (•). REMARKS: TESTEDBY: JW Respectfully submitted, CHECKED BY: WN Iv{© u u << SSAM S. NAAMANI, P.E. As a mutual protection to clients, the public and oursehes, all reports �111 I 4 ���� FEDERAL ENGINEERING & TESTING are submitted as the confidential property of clients, and authorization • UL. FLORIDA REG. #39584 for publication of statements, conclusions or extracts from or regardingour reports is reserved pending:our written approval. - .. BTIIp11C Il;iO fnK:I - -