Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method . r%%1 Project Name: WYNNE THE STERLING Builder Name$ IN DE 04 Street: THE STERLING T L �LEN-Vj T. Permit Offici L �,I 1 11 !SO City, State, Zip: FT;gIERQ�, FL, Permit Numb Owner: - R40 Jurisdiction: Design Location: FE. Fort Pierce County:: St. Lucie (Florida Climate Zone 2 1. New construction or existing New (From Plans) 9. Wall Types(1442.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R--1 1.0 192.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling Types (1474.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1474.00 ft2 6. Conditioned floor area above grade (ft2) 1474 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. WA R= ft2 11. Ducts R ft2 7. Windows(141.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 300 a. U-Factor: Sgi, U=0.63 101.25 ft2 SHGC: SHGC=0.25 b. U-Factor., Sgl' U=0.65 40.00 IT2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 34.8 SEER:15.00 c. U-Factor. WA ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: WA ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. SCAN[Vilzzo Area Weighted Average SHGC: 0.239 14. Hot water systems 8. Floor TKes (1 47-3.6 scift.) Insulation Area a. Electric St. BY Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft2 LucieCoUnty b. Conservation features EF: 0.970 b. NIA R= ft2 None c. N/A R= ft, 15. Credits Patel Glass/Floor Area: 0.096 Total Proposed Modified Loads: 48.34 PASS Total Baseline Loads: 48.53 I hereby certify that the plans and specifications covered by Review of the plans and VVJE S this calculation are in compliance with the Florida Energy specifications covered by this 0 Code. calculation indicates compliance with the Florida Energy Code. "o PREPARED BY: Before construction is completed DATE: -LAt:!A this building will be inspected for compliance with Section 553.908 I hereby c;r1ify that.this building, as designed, is in compliance Florida Statutes. with the Fibrida Energy Code WE OWNER/AGkK N BUILDING OFFICIAL: DATE: - DATE: - - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4A.2). 4/4/2018 10:16 AM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 PROJECT Title: WYNNE THE STERLING Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1474 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180 Street: THE STERLING Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL. New/Existing: New (From Plans) Comment: CLIMATE V Design Temp Int Design Temp Heating Design DailyTemp Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL—VERO—BEACH—MUNI 39 90 70 75 299 62 LOW BLOCKS Number Name Area Volume 1 Entire House 1474 11792 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated I BEDROOM 329 2632 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M. BATH 66 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 6 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 39D4 No 0 1 Yes Yes Yes FLOORS V# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet — 1 Slab -On -Grade Edge Insulatio BEDROOM 62 ft 0 329 ft2 0 1 0 — .?Slab -On -Grade Edge Insulatio WIC ift 0 63 112 0 1 0 10 — 3 Slab -On -Grade Edge Insulatio M.BATH 8ft 0 66 ft' 0 1 0 — 4 Slab -On -Grade Edge Insulatio KITCHEN Ift 0 192 ft2 0 1 0 — 5 Slab -On -Grade Edge Insulatio BATH 5ft 0 46 ft2 0 1 0 — 6 Slab -On -Grade Edge Insulatio, BEDROOM 2 32.2 ft 0 203.5 ft" 0 1 0 — 7SIab-On-Grade Edge Insulatio ENTRY 7ft 0 65 ft2 0 1 0 414/2018 10:16 AM EnergyGauge4l) USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 �ORM R405-2017 I FLOORS V# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet - 8 Slab -On -Grade Edge Insulatio LAUNDRY 6ft 0 42 ft2 0 1 0 - 9Slab-On-Grade Edge Insulatio GREAT/DINING 46ft 0 488 ft2 0 1 0 ROOF Roof V Gable Roof Solar SA Emitt Emilt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) ;1 Gable or Shed Metal 1653 ft2 246 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC V Type Ventilation Vent Ratio (I in) Area RBS IRCC Full attic Vented 150 1474 ftz N N CEILING V# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type - I Under Attic (Vented) BEDROOM 30 Blown 329 112 0.1 Wood - .2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood - .3 Under Attic (Vented) M.BATH 30 Blown 56 ft2 0.1 Wood - :4 Under Attic (Vented) KITCHEN 30 Blown 192 11:2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood - 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood - .7 Under Attic (Vented) ENTRY 30 Blown 55 Itz 0.1 Wood 8 Un der Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft2 0.1 Wood WALLS Adjacent cavity Width y Height Sheathing Framing Solar Below A Ornt Tn Minil lypp Space P-%/.I..e Et In Et in Arpn R-Nfnhip Frpr4inn AhScr rmrip0l, - 1 NE=>SW Exterior Concrete Block - Ext InsiHEDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 -2 SW=>NE Exterior Concrete Block - Ext Insi3EDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.6 0 3 NW=>SE Exterior Concrete Block - Ext InsiHEDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0 4 SW=>NE Exterior Concrete Block - Ext InsulM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 5 NE=>SW Exterijor Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.6 0 6 NE -->SW Exterior Concrete Block - Ext InREDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.6 0 7 Sli=>NW Exterior Concrete Block - Ext InMEDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 8 S=>N Exterior Concrete Block - Ext InfiEDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.6 0 9 SW=>NE Exterior Concrete Block - Ext InfilEDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.6 0 12 SW=>NE Exterior Concrete Block - Ext lnsLUAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 13 NE ->SW Exterior Concrete Block - Ext InsGREAT/DINI 4.1 26 0 8 0 208.0 ft2 0 0 0.6 0 14 NW=>SE Exterior Concrete Block - Ext InsOREAT/DINI 4.1 20 0 8 0 160.0 ft2 0 0 0.6 0 - 15 N =>S Garage Frame - Wood KITCHEN 11 24 8 192.0 11:2 0.23 0.6 0 4/4/201Er,i0:16AM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 rORM R405-2017 DOORS Omt DoorType Space Storms U-Value Width Ft In Height Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft2 WINDOWS Orientation shown is the entered orientation (=>) changed to Worst Case. Wall V Ornt. ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening — 1 NW=>SE 3 Metal — 2 SW=>NE 4 Metal SE=>NW 7 Metal 4, NE=>SW1 3 Metal 5 NW=>SE14 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes 0.63 0.25 N 32.9 ft2 1 ft 0 in 1 ft 4 in 0.63 0.25 N 6.9 ft2 1 ft 0 in 1 ft 4 in 0.63 0.25 N 24.0 ft2 6 ft 0 in 1 ft 4 in 0.63 0.25 N 37.5 ft2 1 ft 0 in 1 ft 4 in 0.65 0.21 N 40.0 112 8 ft 0 in 1 ft 4 in Drapes/blinds None None None Drapes/blinds Exterijor 5 None None None Exterior 5 GARAGE Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 316 ft' 315 ft2 24 ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA Eql-A ACH ACH 50 I Wholehouse Proposed ACH(50) .000356 1375.7 75.53 142.04 .2598 7 HEATING SYSTEM V Syptem Type Subtype Efficiency Capacity Block Ducts I Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM y # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts I Central Unit/ Split SEER: 15 34.8 kBtulhr cfm 0.85 1 sys#1 HOT WATER SYSTEM V .# System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM V FSEC ,Carl # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None ' None ft2 4/4/20181�0:16AM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 I FORM R405-2017 DUCTS V Supply Return -- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool Attic 6 300 ft2 Affic, 75 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Coolin n Heating Jjan 9 F:b F b Mar M ar Apr A r � May I May n un �Xj JJu ul Jul �j J Au 9 Au 9 ri Se P Sep rl Oct Oct Nov Nov Dee Dec Venting Jan Feb X X Mar Apr May Jun Jul Aug Sep Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (VVD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM so 80 78 78 78 78 78 78 78 78 78 78 Cooling (VVVH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (VVEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4/4/2018 10:16 AM EnergyGauge@ USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE STERLING Builder Name: WYNNE DEVELOPMENT Street: THE STERLING Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner. Jurisdiction: Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door iambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned Spec Bs. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around Wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind pipino and wirino Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire snrinkler cover niates and walls or ce6linas a. in aciaition, inspection ot log walls Shall be in accordance with the provisions of ICC-400. 4/4/2018 10:16 AM EnergyGaugeV USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of I FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) D1 SPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. THE STERLING, FT. PIERCE, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R--4.1 1250.00 ft' b. Frame - Wood, Adjacent R-- 11.0 192.00 ft2 3. Number of units, if multiple family 1 c. K/A R-- ft2 4. Number of Bedrooms 2 d. N/A R= ftZ 5. Is this a worst rase? Yes 10. Ceiling Types Insulation Area a. Under Attic (Vented) R=30.0 1474.00 ft2 6. Conditioned floor area (ft2) 1474 b. MIA R= ft2 7. Windowe* Description Area c. N/A R= ft2 a. U-Fador., SgI, U=0.63 101.25 ft2 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic R ft2 6 300 SHGC: SHGC=0.25 b. U-Fac.tor., Sgl, U=0.65 40.00 ft2 SHGC: SHGC=0.21 12. Cooling systems kBtu/hr Efficiency c. U-FaGtor., N/A ft2 a. Central Unit 34.8 SEER:15.00 SHGC: d. U-Fa�or: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 3,832 ft. a. Electric Heat Pump 34.8 HSPF:8.60 Area Weighted Average SHGC: 0.239 8. Floor Types Insulation Area 14. Hot water systems Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft2 a. Electric EF: 0.97 b. N/A R= ft2 c. N/A R= ft2 b. Conservation features None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant featu ate: Builder Signature: Address of New Home:n City/FL Zip:-I;��\_ *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/4/2018 10:16 AM EnergyGaugeO USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 wrightsoft- Project Summary Entire House QUICKCALCS, INC. FL 34946 Phone: 772-466-6799 Fax 772-46"796 For WYNNE DEVELOPMENT THE CARLTON 299, FT. PIERCE, FIL N. Job: Date: By: SCANNED BY St, Lucia County Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TO 28 OF Design TO 15 OF Dail 'y' Rumidity L Relative 50 % Moisture difference 61 gr/lb HeatingSummary Sensible Cooling Equipment Load Sizing Structure 18188 Btuh Structure 17877 Btuh Ducts 5654 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh Central veni (0 cfm) 0 Btuh ne ) ARto (none) u H r [cation 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23842 Btuh Use manufacturer's data n Rate/swi mult lier 0.95 Infiltration EquipmewsensiM load 25093 Btuh Method Simplified Construction quality Average Latent Cooling Equip izing mentLoadSi , Fireplaces 0 Structure 2958 Btuh Ducts - 2319 Btuh Central vent (0 cfm) Btuh H t' coolin (none) Area (ft-) 14 14 Equipment latent load 5277 Btuh Volume (ft3) 12227 12227 Air chan vesfhour 0.45 0.23 Equipment total load 30370 Btuh Equiv. A F (cfm) 92 47 Req. total capacity at 0.70 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary. Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC63WO30 Cond 25HBCS36WO30 AHRI ref 7914585 Coil FX4DN B,F)037 Efficiency 8.5 HSPF AHRI ref 79140 Efficiency 12.0 EER, 15 SEER Heating input Sensible cooling 24360 Btuh Heating output 34600 Btuh @ 47*F Latent cooling 10440 Btuh Temperature rise 27 OF Total coolin 34800 Btuh Actual air flow 1160 cfrn Actual air 0 figw 1160 cfm Air flow factor 0.049 cfim/Btuh Air flow factor 0.044 dm/Btuh Static pressure 0.50 in H20 Static pressure 0.50 in H20 Space thermostat Load sensible heat ratio 0.83 Capacity balance point 33 OF Back T� Input kW, Output= 23009 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoIr Right-SufteD Liniversal 2017 17.0.14 RSLI08101 2017-Apr-10 17:14:53 ... Wdghtso . ft WACXWYN I NEE -THE GRAND CARLTON.299.mp Cale-W8 FrontDoorfaces: N Page I wrightsoft RighW@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE Ll FT. PIERCE, FL 34946 Phone: 772-46"799 Fac 77246"796 Ennal: QUICKCALCS@AOL.COM 1 Roomnarme Entire House BEDROOM 2 EVcsed wall 156.2 ft 52.0 ft 3 Room height 8.3 ft d &0 If heaticool 4 Room dimensions 1.0 x 329.0 ft 5 Room area 1473.5 ft2 329.0 ft. TY Or HTM Area (ft2) Load Am ftl Load ICorstrudw number (,u-value tuWftgF) (Btuh1ftj or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) I Heat I Cool Gross WRIS Heat Cool Gross N/p/S Heart Cool 6 13A40CS 0.143 �mi �400 255 -70:43 479, 442- 1768 1124' '80 90 320 �204 1.Z70 �ema ';�'-'35:56 r- .38 �O -1344 2662 '0 0 -0 0.143 so 4.00 2.55 128 83 331 210 0 0 0 '0 0 T�g IA-clorn 1.270 as 35.56 34.77 24 48 848 829 0 0 0 0 11DO 0.390 as 10.92 11.31 22 22 236 244 0 0 0 0 JaPAccs .0.143',s, 4.00 255 34 -34 136 86 0 0 0 13AAocs 0.143 sw 4.00 Z55 360 353 1414 899 22A '0 224 897 670 1A-c1cm . 1270 sw 35.56 4291 7 11 247 298 0 0 0 0 IT, 1344OCi- , ' . 0.143 - m" 4.00 - 255 290 .217 867 551 112 �'79 318 �nvv 35.56 45.24 7. 33 - 0 1162 1478 ::33 0 "L -13 40.7,70 nve, 21.56 - Z7.54 41 -880 1124 A .1162 0 ,�1478 126:5;w 0.091 2.55 1.28 192 192 489 246 0 10 0 0 0 t ". IM36M., . 0.032 A90 232 1474 147.4 1320 A419 .329 329 295 763 F 22A-tPi 0.9a9 Z7.69 0.00 1474 156 4325 0 329 52 1440 0 61 )ArD =.,I. 784 6BO Envelope loss/gain 16366 13954 4432 3897 12 a) Infiltration 2822 773 909 249 b) Room ventilation 0 0 0 0 13 Internal gn: Occupants @ 230 5 1150 2 460 Applimces/other 2000 0 Subtotal omes 6 to 13) 18188 17877 5341 4606 Less e)demal load 0 0 0 Less transfer 0 0 Redistribution 0 0 14 Suttotal 18188 17M 1151 Duct loaft 31% 48-1. 5654 &%6 Total rcown load 1 23842 26413 Air required (cfm) 1160 1160 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. ,4g& -Fp- �rllglhli��flk� Right-Suiteg Universal 2017 17.0.14 RSU08101 2017-Apr-10 17:14:63 ... Wrightsoft WAC%VVYNNE-THE GRAND CARLTON-299.nup Cato - M.18 Front Door faces: N Page I wrightsoft- Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE I.N., FT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Emil: QLnCKCALCS@AOLCOM 1 Room name WIC M. BATH 2 Exposed wall a Ift 8.0 ft 3 Roorn height 110 ft heat1cool 8.0 ft heatIODDI 4 Room dIntensions 7.0 x 9.0 ft 7.0 x 8.0 ft 5 Room area 63.0 ft' 5&0 ft2 Ty constructim U-,Mue Or HTM Area (ft5 Load Area (ft-) Load number (BtulVft-F) (Btuwftl or penmeter (ft) (Btuh) or perimeter (ft) (Btuh) Gross NIPJS Heat cool Gross WKS Heat Cool 6 VAt-:. '�'13A4xs, '0143 no .4.00 2.55 :a 0-1 '0 0 0. �1. 0 -,no :35.56 -70.43 o o '0 0 0 -.0 lt:mmaG iak4ocs 0.143 as 4.00 2.55 0 0 0 0' 0 0 -0 0 0 1A-clorn 1.270 se 35.56 34.77 0 0 0 a 0 0 0 0 11DO 0.390 so ID.92 11.31 0 0 0 0 0 0 0 0 W�---� j344ccs- 0143 '&.143 - a 400 255 0' '0 .0 0 �-'O' -0- --0 Y-G 13A�Iccs sw 4:00 255 0 0 0 0 64 S7 228 145 1A-clam 1.270 sw 35.56 42.91 0 0 0 0 7 5 247 298 AM4&s, 0. 43 I ' ' �nw 4fDO �2.55 0 �O 0 0. 0., 0 0 0 1A:c1cm 1:270 �35.56 -45.24 :0 0 0 0 0 -0 -0 -0 0.770 Imi' �-21.56 --,27;54 - 0 0 0 .0 0 '0 -0 P 12C-Osw 0.091 - 2.55 1.28 0 0 0 0 0 a 0 D c- nA'3ftd�' 0.032 - �0.90 232 63 63 66 146 56 56 so 130 F 22A-tI% 0.9139 - 27.69 0.00 63 0 0 0 56 8 222 0 6 c)AM cscuralon -2 225 Emelope lossIgain 56 145 747 798 12 a) Infiltration 0 0 140 38 b) Room ventilation 0 0 0 0 13 Internet One: Occupants @ 230 0 0 0 0 Appliances/other 0 Subtotal Qirse; 6 to 13) 56 M 8B7 836 Less estemal load 0 -18--- 0 0 Less transfer 01 0 0 Redistlibution 0 a 7146931% 0 14 Subtotal 66 887 15 Duct foods 31% 48% 5 12% 276 Total noom load 1 1 741 214 1 1162 Air required (cfm) 4 9 67 Calculations approved by ACCA to meet all requirements of Manuel J 8th Ed. �rlghts�ft- 2017-Apr-10 17:14:53 Right-SulteO Universal 2017 17.0.14 RBU08101 Page 2 ... WrIghtsoft WACIWYNNE-THE GRAND CARLTON-299.rup Colo = M.18 Front Door faces: N wrightsoft* Right-.J@ Worksheet Job; Ehdre House Date: QUICK CALCS, INC. BY: 317 ST. LUCIE UL, FT PIERCE, FL 34946 Phone; 772466-6799 FaIc 772-46"796 Ennafl: QUICKCA-CSOIAOLCOM 1 Room nanne KrrcHEN BATH 2 Eximed wall 0 ft 5.0 ft 3 Room height 8.0 It heaticool 8.0 it heat/cool 4 Room dimensions 1.0 x 19zo it 9.0 x 5.0 R 51area 1920 ft2 45.0 ft2 TY 0011sbuctim U-vWue Or HTIVI Axea (III Load Area (Ft2) Load number lstuhift�*F) (Btuh/ftq or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Q)d Gm. N/P/S Heat Old Gross NVP/S Heat Cod - �j 13.4,41ocs -0 143 no ADD 2 55 a 0 0 %0 40 - .. r4O 166 102 L4�4 lxcicnn�* 1' .2�O - na 35.56 �70.43 0 -0 .0 0 0 '.10 '-.0 �o V��13A-400s 0.143 so 4.00 Z55 0 0 0 0 0 0 0 0 IA-clorn 1270 as 35.56 34.77 0 0 0 0 0 0 0 0 11DO 0.390 se 10.92 '11.311 0 0 0 0 0 0 0 0 ':WV.',71-"1P3A'-4ccs, -0.143 a%, -�4.00 2.55 0- -'D 0 �0. 0 ':0 ­0 o 13A4ccs 0.143 sw 4.00 Z55 0 0 0 0 0 0 0 0 IA-clonn 1.270 sw 35.56 42.91 0 0 0 0 0 0 0 0 ,V"�-� ' 113A;46cs�' A.143 nW `rmf,z. i ::4;00 -�2.55 .0 0 �.0 0 -.0 -0 �'1270 W.56 -�45.24 D 0 'i --'�o -0 .0'. 0 0 0 4 "OPT70 nve 21.56 :,27.54 10 �W 0 %0: 0 0 P 12C-Osw '16AMmd,- 0.091 2.55 1.28 64 64 163 82 "o 0 C .0 0 0 . 0.032 0.90 Z32 2., 192 192 172, 445 -46 45 40 �104 F 22A-tol 0.989 27.69 0.00 192 a 0 4E 5 138 0 6 c)AED amursion -27 -2 Envelope loss/gain 335 501 339 204 12 a) Infiltration 0 0 97 24 b) Room ventlhation 0 0 0 0 13 Internal gains: Occupants @ 23D 0 0 0 0 ApIlanceslother 20M 0 Subtotal (11res 6 to 13) 335 2mi 426 228 Loss eAemal load 0 0 0 0 Laos transfer 0 0 0 0 Redistribution 0 0 01 14 Subtotal 335 2501 426 '0 228 15 Duct loads 31%1 481/61 104 1194 31% 481,61 133 109 1 Total noorn load I 1 1 439 W95 3W Ar nequired (cfm) 21 162 2;7;F 15 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �rIghtsoifV 2017-Apr-10 17.14:53 Right-SuiteV UnIvemal 2017 17.0.14 RSU08101 Page 3 ... WrIghtsoft WACIWYNNE-THE GRAND CARLTON-299.mp Colo = MJ8 Front Door faces: N wrightsofr Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE UL, FT PIERCE. FL 34946 Ph,,e; 772-466-6799 Fac 772-466-6796 Email: QUICKCALCS@AOLCOM 1 Room name BEDROOM 2 ENTRY 2 EVesed wall 32.2 If 7.0 If 3 Room hefght 8.0 ft heat/cool 8.0 If heat/Cool 4 Room climenslars 1.0 x 203.5 If 1.0 x 55.0 ft 5 Room am 203.5 ft- 55.0 ft2 TY Constructim U-value Or HTM Am (ft5 Load Am (ftj Load number I (BtWft-'F) (BtUWft2) or Wmetu (ft) (Btuh) or perimeter (ft) (Btuh) I Heat Cool Gross NIFIS Heat cool Gms WPI a Heat cool 6 IN [�LL6 13AAods 1 -0.143,;ne . 255 '128 128 513 326 0 0 0 " �,d 1AclorW�.- .1.270 :ni-. -,fC0 '35.56 70.43 .0 0,1_11 � 0 , 0 0 0: `0 'A 'P13A-4= 0.143 se 4.00 Z55 80 56 226 143 48 26 16i 67 IA-clom 1.270 as 35.56 34.77 24 24 848 829 0 0 0 0 1� 11DO 0.390 so 10.92 11.31 0 0 0 0 22 22 236 244 -D ASAAoos 0.143 "-,a 4.00 2.55 34 34- 136, 86 0 - 0 0 13A-4ocs 0.143 sw 4.00 2.55 16 16 64 41 8 8 32 20 1Aclom 1.270 sw 35.56 42.91 0 0 0 0 0 0 0 0 ty, �:13A;4ocs'- JAcl ' 0.143 ' nw ' 4.00 255 0 �O --o 0 .0 0 0 0 "-"o L,:Cm,,, 1270 r* 35.56 45.24 0. 0;., - 0 0, 0 .,,O.T70 nw. 21.66 27.54 0 :0 0 0 0 0 0 P 12C-Osw 0.091 - 2.55 1.28 0 0 0 0 72 72 183 '0 92 C 16A-3&nd 0.032 - 0.90 232 204 234 182 472 55 66 49 128 F 221AAPI 0.983 - �.69 0.00 204 32 891 0 55 7 194 0 6 c)AED e=rslort -241 -6 Emlope loas/galn 2859 1873 800 545 12 a) hfiftrallon 564 154 122 34 b) Room ventilatlan 0 0 0 .0 13 Lntemal game: Occupants @ 23D 230 0 0 Aptellances/other - 0 0 Subtotal qlres 6 to 13) 3422 2257 922 679 Less cedernal load 0 0 0 0 Less traraer 01 001 01 Redistribution 0 0 0 14 &fttal 3422 2267 M U9 15 Duct loaft 31% 48% 10M 1076 31 %1 1 w 276 Total room lead 44N 33351 1 1 1209 M Air required (cfm) 2 ,.1 591 3a Cdculations approved bvACCA to meet all reauirements of Manual J 8th Ed ,&k -Fk- wrightsaft- Right-Sultelf, Universe] 2017 17.0.14 RSU08101 2017-Apr-10 17:14:53 ... Wrightsoll WAC%WYNNE-THE GRAND CARLTON-299.mp Cole = MJ8 Front Door faces: N Page 4 wrightsaft' Right-JO Worksheet Job: Enike House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-46"799 Fae: 772-466-6796 Emil: QUCKCALCS@AOL.COM 1 Room name LAUNDRY GREAVDINING 2 Sqmed wall 6.0 ft 46.0 ft 3 Room height 8.0 ft heaUcool 8.9 R heall000l 4 Room dimensions 7.0 x 6.0 It 1.0 x 488.0 Ift 5 Room area 42.0 ft2 488.0 ft2 Ty Construction U-value Or HTIVI Am (ft-) Load Anaa (Iftj Load number (BlulVft�*F) (Btuiv" or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat cool Gross N/p/S Heat cool Gross I NIFIS Heat cool 6 T-'- 13AAOCs 0.143 ."Pa. T 4:00 '2.55 A-. 0 �O 0 231 -.194; ',776 -1493 -6 � -.G - ..�"...1270 , "ner 35.56 70.43 10 ..0 0,, 38 0 1344 V�j lak4ocs 0.143 se 4.00 Z55 0 0 0 .0 0 0 0 0 0 1Aclom 1.270 se 35.56 34.77 0 0 0 0 0 0 0 0 1 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 �j3k-4ocs :- 0:143 " s,,. A.00 :265 o 0 0 0 0, 0 t13k400s 0.143 sw 4.00 255 48 48 192 122 0 0 '�'O 0 0 1A-clam 1270 sw 35.56 4291 0 0 0 0 0 0 0 0 -G -DA43 'nid. 4:00 Z55 0 0 -'0 �O 178;* 137 50 '349 Mmc�cwn� 'J.270 rid i.-.35.56 45.24 0 0 0 - :ul 01- , , 0:... - : 0 ---'--0 4A54om'%'1 0770 'rw 21' 156 27.54 0 '0 I .-I - 0 o- �41 �o - �880 � I 11124 P 12C-Dsw 0.091 - 2.55 1.28 56 56 143 72 0 0 0 0 C 1BA13ftd 0.032 - 0.90 2.32 42 42 38 97 488 488 437 1132 F 22A-tpi 0.989 - 27.69 0.00 42 6 166 a 488 46 1274 0 61 c)A9 mursion -3 -W Envelope loss/gmn 539 288 5M 6704 12 a) Infiltration 105 29 895 245 b) Room Ventilation 0 0 0 0 13 Internal gains: Owupants @ 230 0 0 2 460 Applianoestother 0 0 Sul)total Olnes 6 to 13) 644 317 6154 6409 Less extemal load 0 0 0 0 Less firansfer 0 0 0 0 Reft1fibutim 0 0 D 14 Silletotal 644 317 6154 6409 115, Duct loads 31%1 48Y.1 2DO 15011 31%1 48% 1913 w6c) To a] room load M 4M 1 8067 9M ArreqWrad (cfm) 41 211 393 416 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed ',g& -F14- �riighlts�ft- Right-SulleG Unh,ersal 2017 17.0.14 RSU08101 2017-Apr-10 17:14:63 ... Wflghtsoft WACkVVYNC-THE GRAND CARLTON.299.mp Calc=MJS FrontDoorfaces: N Page 5 wrightsoft Duct System Summary Job: Date: Enfire House By: QUICK CALCS, INC. 317 ST. LUCIE LK, FT PIERCE, FL 34946 Phone: 772-46"799 F" 772-466-6796 Email: QUCKCALCS@AOL.COM For WYNNE DEVELOPMENT THE CARLTON 299, FT. PIERCE, FL E)demal static pressure Pressure losses Available static pressure Supply/ return available pressure Lowest friction rate Actual air flow Total effective length (IFEL) 0.50 in H20 0 -in H20 0.50 in H20 0.250 / 0.250 in H20 0.284 in/100ft 1160 cfm Cooling 0.60 in H20 0 in H20 0.60 in H20 0.250 / 0.250 in H20 0.�84 in1100ft 1160 afm 176 ft Name Design (Btuh) Htg WITI) Cig (Cfrn) Design FR Diann (I n) HxW (I n) Duct Mat] Actual Ln (ft) Ftg.Eqv Ln (ft) Trunk BATH h 559 27 15 0.376 4.0 OxO VIFx 18.1 115.0 sti BEDROOM 2 h 4486 218 146 0.374 6.0 OxO VlFx 18.6 115.0 stl BEDROOM -A h 3501 170 149 0.297 6.0 OxO VIFx 33.1 135.0 st2 BEDROOM-B h 3501 170 149 0.284 6.0 6xb viFx 41.1 135.0 st2 ENTRY h 1209 59 38 0.510 4.0 OxO VIFx 3.0 95.0 GREATFDINING 0 4735 196 208 0.318 7.0 OxO VlFx 22.4 135.0 st2 GREAVDINING-B c 4735 196 208 0.307 7.0 0x0 VlFx 28.1 135.0 st2 VJTCHEN c 3695 21 162 0.375 7.0 OxO VIFx 18.3 .115.0 sti LAUNDRY h 844 41 21 0.366 6.0 OxO VIFx 21.6 115.0 sti M. BATH In 1162 57 54 0.366 4.0 0XID VIFx 21.6 115.0 sti I WIC C 214 4 9 1 0.310 4.0 OxO VlFx 26.3 135.0 st2 Trunk Htg, HxW Duct Name Type (Cfm) Ci n) Material Trunk W Peak AVF 737 0 x 0 VinIFIx sti sti Peak AVF 1101 0 x 0 VinlFIx wrilqhtsafll� Right-S.ReSUnivema]201717.0.14RSU08101 2017- 1 Apr-10 17.14:54 ... Wrightsoft WAC\WYNNE-THE GRAND CARLTON-299.mp Calc = MJ8 Front Door faces: N Page 1 Name Gdlle Size (in) � Htg (Cfm) Cig (cfm) I TEL M Design FIR Veloc (fpm) Diam I (in) HxW Ci n) Stud/Joist Opening (in) Duct Matl I Trunk rbl OxO 1 11601 11601 0 1 01 01 01 Ox o I VlFx 2017-Apr-10 17:14:54 *wrightSoft' Right-Buite@Llnivema]201717.0.14RSU08101 Page 2 ... Wdghtscd WACIWYNNE-THE GRAND CARLTON-299.mp Calc = MJ8 Front Door faces: N